12固定式钢直梯安全检查表
- 格式:xlsx
- 大小:12.01 KB
- 文档页数:1
A B ID I NSPECTION P OINTV ISUAL C RITERIAO BSERVATION N OTESFixed Ladders :01Is the fixed ladder securely fastened or attached to the wall or mounting surface at the top and the bottom?固定的梯子的底部和顶部是否牢固的固定在墙上或安装表面上?Criteria: Fixed ladders must be secured at least at the top and bottom of the ladder, and must be tightly and permanently fastened to the mounting surface. All fasteners must be tight and without damage or corrosion. 固定的梯子安全,至少顶部和底部必须牢固且永久的固定在安装面上,所有紧固件必须拧紧且腐蚀和损伤。
Look for:30”(0.8 m)30”(0.8 m)•Secure and undamaged attachment to wall•Straight and undamaged rails and rungs•Rust-free fasteners, rungs, and railsAnnual02Are the rungs and beams of the fixed ladder free of corrosion, burrs, dents, unintentional bends or cracks?梯子的梯级和横梁是不是没有锈蚀、毛刺、龟裂、非人为的弯曲和裂缝。
Criteria: Fixed ladder rungs and beams must be free of any structural damage such as flaking rust or corrosion, dents or cuts in the rungs or beams, bent rungs or beams from overloading or impact, and cracks in welded joints.固定的梯级和横梁必须避免任何结构性的损坏,例如生锈或腐蚀脱皮、阶梯或横梁的龟裂和断痕、超载或冲击造成梯级或横梁弯曲、焊接点裂缝。
钢筋爬梯安全检查表
受检单位负责人
检查地点检查时间
序号检查内容是否一钢筋爬梯的制作是否符合以下要求
1 钢筋爬梯应采用A3钢
2 钢筋直径应不小于12mm
3 挂钩无伤痕、无裂口
4 横档必须焊接牢固
5 梯身每隔3m设一道长15cm的撑框
长度超过10m的爬梯,中间每隔5m应与构筑物
6
绑牢
二钢筋爬梯的使用是否符合以下要求
1 使用时上部必须牢固地连接在构筑物上
2 在钢筋爬梯上不得拉设电源线
3 严禁将钢筋爬梯作为接地线使用
固定梯子的构筑物上部拆除后必须立即把梯子
4
全部拆掉
5 上、下梯子时应面部朝内
6 在梯子上工作应备好工具袋
7 应有防止落物打伤梯下人员的措施
8 在转动机械附近使用时,应采取隔离防护措施
检查记录:
检查人:。