压缩空气系统维护保养记录

  • 格式:doc
  • 大小:146.50 KB
  • 文档页数:6

FRM-000305 Version : 02Effective from : 29.10.2008SOP reference: SOP-000347Preventive Maintenance Record for Compressed Air System压缩空气系统维护保养记录Approvals 批准人: Name 姓名: Date 日期: Signature 签字:Author 作者 :Approvers 批准人:Final Approver 最终批准人:Applicability : document applies for Beijing Novartis Pharma Ltd.All Plant QC QA HR/Adm in. ProductionProcessingPackagingSem i SolidEngineering SCM BPAother :Replaces No: FRM-000305 Version 01 Reason for Change:Detailed ‘How to do it ’ was added. 6 items was added. Translate to Chinese. Reference SOP : SOP-000347Preventive Maintenance Record for Compressed Air System压缩空气系统维护保养记录NB. for daily routine maintenance refer to FRM-000306: Monitoring Logbook for Compressed Air System被注:日维修记录在FRM-000306。

1 Quarterly季度维护保养Quarterly PM Checklist WO No.:Responsible Technician: Scheduled Date:Item Content Acceptance Criteria Result Signature/Date1.1 Clean Compressor-s(Blow the inside using CA;Blow the electrical elements using CA; swab thesurface)清洁压缩机组(使用压缩空气吹扫空压机内部,吹扫电气元件,擦洗表面)Visually Clean.No derbies or dust on the main parts ofthe compressors目视干净。

无灰尘在压缩机组件上。

1.2 Check for possible leaks(check the soft pipe inside; check leaks for joints,flange, valves, filter which located in air compressorstation, distribute piping and air tank)检查泄漏。

(检查空压机组的内部软管,油管,气管;检查空压站/分配管路/用户点的球阀,安全阀,贮气罐及其附件,过滤器,管道,接头,法兰和密封)No obvious leaks from pipes, joints andseals没有泄漏。

1.3 Check coolers, clean if necessaryObserve if fins and openings are clean(blow the middle cooler, end cooler and oil cooler)Fins are clean and not blocked干净,无阻挡。

SOP reference: SOP-000347 Page: 1/4压缩空气系统维护保养日志Item Content Acceptance Criteria Result Signature/Date 检查和清洁冷却器(吹扫油冷却器,中间冷却器,末冷却器,再生空气冷却器,风扇,压缩机头和电动机。

1.4 Check the Dryer(Watch the dryer material color through the smallglass window)检查空气干燥机(通过玻璃视窗观察干燥剂)The dryer material color is blue, andmaterial is granule, not powder.干燥剂颜色为蓝色,呈颗粒状,无粉末。

1.5 Check the automatically drainage valves.(watch the running lamp; press the test button)检查5个电子自动排污阀(观察运行灯,按“test”按钮)The running lamp(green) is light,trouble lamp(yellow) is dark. A sound‘Pa’ should be heard when press thetest button.运行灯(绿)亮,故障灯(黄)灭,按“test”按钮,应该听到“啪”的一声,意味着阀门可以被打开1.6 Check the oil(watch it through the glass windows)检查油(通过油窗观察)The oil level is between the two redlines. and the oil is clean and lucidity油位在两道红线之间,油清澈透明。

1.7 Check motor and compressor(hear and smell)检查电动机和压缩机(听,闻)No strange noise, no terrible smell.无杂音,无异味1.8 Check the press gauge(Firstly close the valve, then slowly open it again)检查压力表(先关闭下部的阀门,然后再缓慢打开)The hand should move to “0” whenclose the valves, and come back whenslowly open it again.关闭下部的阀门后,指针应移到0位,SOP reference: SOP-000347 Page: 2/4压缩空气系统维护保养日志Item Content Acceptance Criteria Result Signature/Date打开阀门后恢复读数。

1.9 Check the safety valves检查安全阀(观察)(watch it)The plumbum seal is no damaged.铅封完好2.0 Walk down pipeline check for leaks(watch, hear and touch)沿线检查管路(观察,听,摸)No leaks from seams, flanges, valves,and other fixtures无泄漏2.1 Check the site humidity instrument(watch it)检查在线露点仪(观察)The tube no leak, the element nodamaged. The pressure gauge is 0Mpa, the flow meter is 3 l/min管道无泄漏,组件无损坏,压力表读数为0,流量计读数为3 l/min。

2.2 Check the air tank(Partly open the bottom valves)检查压缩空气贮罐(部分地打开底部的阀门)No water, no dirty get out.无凝结水和杂质排出。

Describe repair and maintenance if applicable during Preventive Maintenance briefly: 如果在预防性维护保养其间有其它维修工作被执行,详细记录如下:Reviewed by Clean Utility:Comments:SOP reference: SOP-000347 Page: 3/4压缩空气系统维护保养日志2 Annually年度维护保养Annually PM Checklist WO. No.:Responsible Technician: Scheduled Date Window:Item Content Acceptance Criteria Result Signature/Date Reviewed by/Date Remark2.1 Check for safety devicesoperation ability (allcertificates required in place)检查安全设施(检验证书在现场)Safety devices and valves arecalibrated and certified as perlocal and HSE regulations. Novisual signs of rust, or dust压力表和安全阀门的检验合格证书在有效期内,无损坏,无锈,无尘土。

2.2 Operate the entire valve thatcan be opened or closed byslightly moving their handlesleft or right.操作全部的阀门,轻微地左右移动阀门手柄。

Valve handles move smoothly阀门手柄移动灵活。

Describe repair and maintenance if applicable during Preventive Maintenance briefly如果在预防性维护保养其间有其它维修工作被执行,详细记录如下:SOP reference: SOP-000347 Page: 4/4压缩空气系统维护保养日志Reviewed by Clean Utility:Comments:SOP reference: SOP-000347 Page: 5/4。