大功率单项逆变器U3988数据手册V5
- 格式:pdf
- 大小:2.10 MB
- 文档页数:5
资料范本本资料为word版本,可以直接编辑和打印,感谢您的下载逆变器用户使用手册地点:__________________时间:__________________说明:本资料适用于约定双方经过谈判,协商而共同承认,共同遵守的责任与义务,仅供参考,文档可直接下载或修改,不需要的部分可直接删除,使用时请详细阅读内容GDLYEC-PV-3~270/500光伏并网逆变器用户使用手册版本2.0国电龙源电气有限公司目录TOC \o "1-3" \h \z \u HYPERLINK \l "_Toc327278738" 1关于本手册 PAGEREF _Toc327278738 \h 3HYPERLINK \l "_Toc327278739" 1.1 前言 PAGEREF_Toc327278739 \h 4HYPERLINK \l "_Toc327278740" 1.2 内容简介 PAGEREF_Toc327278740 \h 4HYPERLINK \l "_Toc327278741" 1.3 面向读者 PAGEREF_Toc327278741 \h 4HYPERLINK \l "_Toc327278742" 1.4 手册使用 PAGEREF_Toc327278742 \h 4HYPERLINK \l "_Toc327278743" 2 安全须知 PAGEREF_Toc327278743 \h 5HYPERLINK \l "_Toc327278744" 2.1 警示符号说明 PAGEREF_Toc327278744 \h 6HYPERLINK \l "_Toc327278745" 2.2 安全提示 PAGEREF_Toc327278745 \h 7HYPERLINK \l "_Toc327278746" 2.3 操作中的注意事项 PAGEREF _Toc327278746 \h 9HYPERLINK \l "_Toc327278747" 3 产品简介 PAGEREF_Toc327278747 \h 10HYPERLINK \l "_Toc327278748" 3.1 光伏并网系统 PAGEREF_Toc327278748 \h 11HYPERLINK \l "_Toc327278749" 3.2 产品特点 PAGEREF_Toc327278749 \h 11HYPERLINK \l "_Toc327278750" 3.3 电气原理 PAGEREF_Toc327278750 \h 12HYPERLINK \l "_Toc327278751" 3.4 产品外观 PAGEREF_Toc327278751 \h 14HYPERLINK \l "_Toc327278752" 4 产品功能与LCD操作指南PAGEREF _Toc327278752 \h 17HYPERLINK \l "_Toc327278753" 4.1 GDLYEC-PV-3~270/500主要功能 PAGEREF _Toc327278753 \h 18HYPERLINK \l "_Toc327278754" 4.1.1 并网发电 PAGEREF_Toc327278754 \h 18HYPERLINK \l "_Toc327278755" 4.1.2 MPPT功能 PAGEREF_Toc327278755 \h 18HYPERLINK \l "_Toc327278756" 4.1.3低电压穿越功能 PAGEREF _Toc327278756 \h 18HYPERLINK \l "_Toc327278757" 4.1.4 保护功能 PAGEREF_Toc327278757 \h 19HYPERLINK \l "_Toc327278758" 4.1.5 远程控制功能 PAGEREF _Toc327278758 \h 20HYPERLINK \l "_Toc327278759" 4.1.6自动开关机功能 PAGEREF _Toc327278759 \h 20HYPERLINK \l "_Toc327278760" 4.2 GDLYEC-PV-3~270/500运行模式 PAGEREF _Toc327278760 \h 20HYPERLINK \l "_Toc327278761" 4.3 GDLYEC-PV-3~270/500 LCD操作指南 PAGEREF _Toc327278761 \h 22HYPERLINK \l "_Toc327278762" 4.3.1 LCD主界面 PAGEREF_Toc327278762 \h 22HYPERLINK \l "_Toc327278763" 4.3.2 LCD控制指令发送 PAGEREF _Toc327278763 \h 24HYPERLINK \l "_Toc327278764" 5 产品安装 PAGEREF_Toc327278764 \h 30HYPERLINK \l "_Toc327278765" 5.1 注意事项 PAGEREF_Toc327278765 \h 31HYPERLINK \l "_Toc327278766" 5.2 机械尺寸 PAGEREF_Toc327278766 \h 31HYPERLINK \l "_Toc327278767" 5.3 放置与移动 PAGEREF_Toc327278767 \h 31HYPERLINK \l "_Toc327278768" 5.4 直流输入线缆连接 PAGEREF _Toc327278768 \h 32HYPERLINK \l "_Toc327278769" 5.4.1 直流输入电气参数规格PAGEREF _Toc327278769 \h 32HYPERLINK \l "_Toc327278770" 5.4.2 直流输入线缆要求 PAGEREF _Toc327278770 \h 33HYPERLINK \l "_Toc327278771" 5.4.3 线缆连接 PAGEREF_Toc327278771 \h 33HYPERLINK \l "_Toc327278772" 5.5 交流输出线缆连接 PAGEREF _Toc327278772 \h 36HYPERLINK \l "_Toc327278773" 5.5.1 交流输出电气规格 PAGEREF _Toc327278773 \h 36HYPERLINK \l "_Toc327278774" 5.5.2 交流输出线缆要求 PAGEREF _Toc327278774 \h 36HYPERLINK \l "_Toc327278775" 5.5.3 线缆连接 PAGEREF_Toc327278775 \h 36HYPERLINK \l "_Toc327278776" 5.6 系统地线连接 PAGEREF_Toc327278776 \h 38HYPERLINK \l "_Toc327278777" 5.6.1 地线线缆要求 PAGEREF _Toc327278777 \h 38HYPERLINK \l "_Toc327278778" 5.7 远程监控通信线连接 PAGEREF _Toc327278778 \h 38HYPERLINK \l "_Toc327278779" 6 产品运行指南 PAGEREF _Toc327278779 \h 40HYPERLINK \l "_Toc327278780" 6.1 启动 PAGEREF_Toc327278780 \h 41HYPERLINK \l "_Toc327278781" 6.2 关机 PAGEREF_Toc327278781 \h 42HYPERLINK \l "_Toc327278782" 7 电气特性 PAGEREF_Toc327278782 \h 431关于本手册关于本章本章介绍了本手册的主要内容、面向的读者、手册使用须知以及手册所使用的符号定义,帮助用户更好的阅读本手册内容。
前言感谢您选择本公司的光伏并网逆变器,我们乐意为您提供一流的产品和优质的服务。
本用户手册包含安全提示、设备安装、操作维护、故障排除等内容,只要您按照本手册的指引操作,您将得到专业的指导以及我们真诚的服务。
客户至上一直是我们努力追求的目标,希望这本用户手册能成为您的好帮手。
该手册根据客户反馈的信息定期更新,最新版本请登陆我们的官方网站下载查看。
广州三晶电气股份有限公司数字化建筑能源管理服务商目录前言................................................ - 1 - 第一章安全注意事项 ................................ - 4 -1.1适用范围 (4)1.2安全提示 (4)1.3使用对象 (4)第二章标识说明 .................................... - 5 -2.1符号说明 (5)2.2标示说明 (6)第三章产品介绍 .................................... - 7 -3.1产品适用范围 (7)3.2产品型号说明 (8)3.3产品外观及尺寸 (8)3.4产品参数 (10)第四章安装说明 ................................... - 18 -4.1安全提示 (18)4.2安装前检查 (18)4.3确定安装方式及位置 (19)4.4安装步骤 (20)第五章电气连接 ................................... - 25 -5.1带电操作安全说明 (25)5.2电气接口说明 (26)5.3交流侧电气连接 (29)5.4直流侧电气连接 (32)5.5通讯连接 (35)第六章调试说明 ................................... - 37 -6.1人机界面介绍 (37)6.2监控操作 (38)第七章故障代码及常见故障排除...................... - 45 - 第八章回收处理 ................................... - 48 - 第九章联系方式 ................................... - 49 - 保修说明........................................ - 50 - 质保卡........................................... - 52 -第一章安全注意事项1.1 适用范围本用户手册介绍光伏并网逆变器安装、维护和故障检修的使用说明和详细步骤,适用于以下型号:R5-0.7K-S1; R5-1K-S1; R5-1.5K-S1; R5-2K-S1; R5-2.5K-S1; R5-3K-S1; R5-3K-S2;R5-4K-S2;R5-5K-S2;R5-6K-S2;R5-7K-S2;R5-8K-S2请保管好本用户手册,以便在紧急情况下使用。
史上最全储能逆变器参数详解前言众所周知,逆变器是光伏系统的关键先生。
小固曾推出《史上最全并网光伏逆变器参数详解》,针对重点参数做出技术解读。
在储能项目中,逆变器、电池等关键设备构成了系统的核心单元。
作为逆变器设备及解决方案供应方,小固针对单相储能、三相储能,储能转换器(DC耦合、AC耦合)等目前市场上多款储能产品,本文将对储能逆变器参数、应用形式、配置方法进行详细介绍。
温馨提示:本文内容翔实,参数详解涉及九大类:直流输入参数、电池参数、输出参数(并网)、输出参数(离网)、通讯情况、基本参数、逆变器保护、逆变器效率、法规及标准。
一、为什么选择安装储能逆变器?•提高更高的自用比例。
白天,光伏发的电供负载使用,多余的电储存在电池里;晚上,光伏不发电,电池的电给负载使用,达到不用电网或少用电网电的目的。
•在电网停电的时候或者电网不稳定的时候,可以自动切换到电池供电的模式,这个切换时间是非常短的(UPS效果),负载可以继续使用。
•双向储能的功效—光伏可以给电池充电,同样的电网的电也可以给电池充电(电费较低的时候);这样可以用电池调开峰谷电价差或当作备用电源来使用。
•纯离网工况下也可以使用,带动一定功率大小的负载工作。
二、储能逆变器的技术参数以最常用的单相储能机型为例。
ES单相储能逆变器外观ES储能机的接线1、直流输入参数小固解读:储能机直流侧共2路输入组串,2路MPP追踪,每串最大输入电流为11A,最大输入电压为580V,MPPT工作电压范围为125~550V,在组串数量设计的时候,要考虑到到组串的开路电压不要超过580V(考虑现场极限温度),工作电压在125~550V之间,建议额定工作电压在360V;若采用285W的板子,建议使用20~22块,组件容量为5.70~6.27kWp为宜)。
2、电池参数电池的电压为48V(额定电压),如果用户使用了2V,12V等电压的铅酸电池,可以通过串联多块电池的方式得到48V的电压。
—SO L A R I N V ERTER SABB string invertersUNO-DM-3.3/4.0/4.6/5.0-TL -PLUS 3.3 to 5.0 kWThe new UNO-DM-PLUS single-phase inverter family, with power ratings from 3.3 to 5.0 kW, is the optimal solution for residential installations.—UNO-DM-3.3/4.0/4.6/5.0-TL-PLUS outdoor string inverterOne size fits allThe new design wraps ABB’s quality and engineering into a lightweight and compact package thanks to technological choices optimized for installations with different orientation.All power ratings share the same overall volume,allowing higher performance in a minimum space, and have a dual Maximum Power Point Tracker (2 MPPT).Easy to install, fast to commissionThe presence of plug and play connectors, both on the DC and AC side, as well as the wirelesscommunication, enable a simple, fast and safe installation without the need of opening the front cover of the inverter.The featured easy commissioning routine removes the need for a long configuration process, resulting in lower installation time and costs.Improved user experience thanks to a build in User Interface (UI), which enables access to features such as advanced inverter configuration settings, dynamic feed-in control and load manager, from any WLAN enabled devices (smartphone, tablet or PC).Smart capabilitiesThe embedded logging capabilities and directtransferring of the data to Internet (via Ethernet or WLAN) allow customers to enjoy the whole AuroraVision ® remote monitoring experience.The advanced communication interfaces (WLAN,Ethernet, RS485) combined with an efficient Modbus (RTU/TCP) communication protocol, Sunspeccompliant, allow the inverter to be easily integrated within any smart environment and with third party monitoring and control systems.A complete set of control functions with theembedded efficient algorithm, enabling dynamic control of the feed-in (i.e. zero injection), make the inverter suitable for worldwide applications incompliance with regulatory norms and needs of the utilities.The future-proof and flexible design enablesintegration with current and future devices for smart building automation.Highlights• Wireless access to the embedded Web User Interface• Easy commissioning capability• Future-proof with embedded connectivity for smart building and smart grid integration• Dynamic feed-in control (for instance “zero injection”)• Remote Over The Air (OTA) firmware upgrade for inverter and components• Modbus TCP/RTU Sunspec compliant• Remote monitoring via Aurora Vision ® cloud • Dual input section with independent MPPT—ABB string invertersUNO-DM-3.3/4.0/4.6/5.0-TL -PLUS 3.3 to 5.0 kW—Technical data and types- varistor2 (L - N / L - PE)—Technical data and types1)“Refer to the document “String inverter – Product Manual appendix” available at/solarinverters to know the brand and the model of the quick fit connector”2)For UK G83/2 setting, maximum output current limited to 16 A up to a maximum output Pacr of 3600 W and a maximum apparent power of 3600 VA 3)The AC voltage range may vary depending on specific country grid standard 4)The Frequency range may vary depending on specific country grid standard;CE is valid for 50Hz only5)As per IEEE 802.11 b/g/n standard 6)Pacr = 4200 W @ 45°C/113°F 7)Further grid standard will be added, please refer to ABB Solar page for further details Remark. Features not specifically listed in the present data sheet are not included in the productABB UNO-DM-3.3/4.0/4.6/5.0-TL-PLUS string inverter block diagramB C D .00680_E N R E V . B 11.10.2018—We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction,disclosure to third parties or utilization of its contents – in whole or in parts – isforbidden without prior written consent of ABB AG. Copyright© 2017 ABB All rights reserved—For more information please contact your local ABB representative or visit:/solarinverters 。
UT8805A五位半台式万用表SCPIREV 002023.06版权2022优利德中国科技有限公司商标信息UNI-T是优利德中国科技有限公司的注册商标。
文档编号软件版本00.00.01软件升级可能更改或增加产品功能,请关注UNI-T网站获取最新版本手册或联系UNI-T升级软件。
声明●本公司产品受中国及其它国家和地区的专利(包括已取得的和正在申请的专利)保护。
●本公司保留改变规格及价格的权利。
●本手册提供的信息取代以往出版的所有资料。
●本手册提供的信息如有变更,恕不另行通知。
●对于本手册可能包含的错误,或因手册所提供的信息及演绎的功能以及因使用本手册而导致的任何偶然或继发的损失,UNI-T概不负责。
●未经UNI-T事先书面许可,不得影印、复制或改编本手册的任何部分。
●产品认证UNI-T认证本产品符合中国国家产品标准和行业产品标准及ISO9001:2008标准和ISO14001:2004标准,并进一步认证本产品符合其它国际标准组织成员的相关标准。
SCPI(Standard Commands for Programmable Instruments,即可编程仪器标准命令集)是一种建立在现有标准IEEE 488.1和IEEE 488.2基础上,并遵循了IEEE754标准中浮点运算规则、ISO646信息交换7位编码符号(相当于ASCII编程)等多种标准的标准化仪器编程语言。
本节简介SCPI命令的格式、符号、参数和缩写规则。
指令格式SCPI命令为树状层次结构,包括多个子系统,每个子系统由一个根关键字和一个或数个层次关键字构成。
命令行通常以冒号“:”开始;关键字之间用冒号“:”分隔,关键字后面跟随可选的参数设置。
命令关键字和第一个参数之间以空格分开。
命令字符串必须以一个<换行> (<NL>) 字符结尾。
命令行后面添加问号“?”通常表示对此功能进行查询。
符号说明下面四种符号不是SCPI命令中的内容,不随命令发送,但是通常用于辅助说明命令中的参数。
使用说明书User’s Manual一、简介 (1)(一)使用说明 (1)(二)注意事项 (1)二、安装与接线 (2)(一)安装环境 (2)(二)安装前检查 (2)(三)安装位置 (2)(四)连接 (2)三、操作程序 (4)(一)术语解释 (4)(二)开机操作步骤 (4)(三)关机操作步骤 (4)四、工作原理 (5)(一)正常运行 (5)(二)电池运行 (5)(三)市电运行 (6)五、技术参数 (6)(一)三进三出技术参数 (6)(二)三进三出技术参数 (6)六、结构功能介绍 (7)(一)控制面板结构功能 (8)(二)前后板结构功能 (10)七、维护与保养 (13)(一)逆变器保养维护和注意事项 (13)(二)电池保养维护 (13)(三)逆变器储存 (13)八、故障处理 (14)九、搬运要求 (15)十、维修与服务 (17)(一)使用说明1、该系列产品采用高速微处理器(MCU)和可编程逻辑器件(CPLD),经软件编程控制。
功率器件采用当今最先进的第五代低损耗大功率IGBT和静态开关。
该系列产品是集国际最新的控制器件和最先进的软件为一体的电源产品。
广泛应用于大楼照明、道路交通照明、电力、通讯、医疗、工矿企业等行业。
2、在某种情况下,逆变器设备可能引起电波干扰,一些敏感的设备(如电视、收音等)可能受到干扰,此时应将其与受干扰物的距离拉远。
3、在安装和使用逆变器时,请详尽阅读此说明书。
(二)注意事项1、如果逆变器应有连接“接地”系统,首先将主输入电源的地线接到逆变器注明有"PE"或“G”的接线端子排上。
2、逆变器在输入,电池及输出开关断开的情况下仍然可能带电,非专业技术人员不要擅自打开逆变器的外壳,否则可能会对逆变器及操作者造成伤害。
3、需要更换保险丝时,应采用相同型号规格的保险丝。
4、逆变器的专用电池应由专业技术人员进行更换,更换出来的电池必须送交回收机构处理,废旧电池根据法律被定为“有毒废料”。