约克YAH电子样本
- 格式:pdf
- 大小:1.56 MB
- 文档页数:6
Fast.Add sample. Load instrument. Press start. One to 16 samples processed in 30–45 minutes. Less hands-on labor. Less manual extraction. More samples in less time with no additional laboratory technicians. Bar code sample identifi cation streamlines sample tracking.Easy.Touch screen operation. Prefi wide variety of sample types: blood, serum, plasma, cells, fresh/frozen or FFPE tissue; and applications: DNA, RNA or total nucleic acid purifi Reliable. Robust operation. Comprehensive service and support. Value-added Installation Qualifi Operational Qualifi validation and documentation. UV light assists with instrument decontamination.for the Clinical Lab Maxwell 16® Instrument issmaller and easier to usethan most automatedsystems. The compactfootprint fi ts right ona bench or inside abiohazard hood. It’s simplein design and reliable tooperate. Processing up to16 samples in 45 minutesmakes it the perfectcapacity for most clinicallabs. So you can deliverbetter results faster andwith confi dence. Personalinstrument. Personalresults. Personal serviceand support. All madebetter with PersonalAutomation.Rapid extractionWhy Maxwell for an infectious diseases lab?An experienced infectious disease lab was using anautomated extraction instrument but was frustrated withextraction failures and cross-contamination.Seasonal disease outbreaks increase demands.When large numbers of samples needed to be processed,the lab went from at capacity to overloaded. Failed ordelayed automated extractions resulted in delays in reportingoutcomes.Maxwell provided the solution.Faster turnaround times began immediately.Optimized viral total nucleic acid extractionkits and automated methods helped meetheavy test volume. Doctors andpatients appreciated the fastand accurate results from theclinical lab.leads to better outcomesReliable extraction for consistent results Increasing numbers of samples push lab capabilities. T he number of solid organ and bone marrow transplants increased, pushing the lab to work faster. Labor-intensive manual protocols led to variable results and errors for less experienced technologists.Maxwell provided the solution.Implementing automation reduced weekly DNA extraction time from sixteen hours a week to less than 4 hours per week with improved consistency and higher yields. Errors were reduced and technologists were able to do more with renewed confi dence. Why Maxwell for an HLA/Transplant lab?An HLA lab was using manual column-based DNA extraction methods but was frustrated by the hands-on time and labor required.Maxwell16 FFPE Tissue LEVConfident operation from comprehensive support and service. Promega provides a series of support and service options so you can always experience the benefits of Personal Automation. Technical support is provided by a global team of technical services scientists, field support scientists and service engineers. Warranties and service plans give you peace of mind, minimal instrument downtime and predictable service costs. The clinical lab demands accurate and thorough documentation of instrument performance. Promega offers Installation Qualification (IQ), Operational Qualification (OQ) and Preventive Maintenance (PM) services to ensure smooth operation. These services help assure that you have adequate training and documentation of performance characteristics.Instrument Specifications Standard Components – All of the AS3000 Maxwell ® MDx Instruments include:• 1 Maxwell ® 16 MDx Instrument • 1 power cable • 1 UV lamp bulb*• 1 SD card • 1 SD card reader package (contains SD card reader and cable)• 1 CD containing the technical manual • 1 Quick Start Guide • 1 Bar Code Reader• 1 CD Containing Data Export Software • 1 RS-232 Cable for communication with a computer or printer • 1 RS-232/USB Adaptor for data export to computer Processing Time 30–45 minutes (depending on sample type and method)Number of Samples up to 16Elution Volume 50-300µl Weight 42.7lb (19.4kg)Dimensions 12.8W x 17.3D x 12.9H inches (33W x 44D x 33H cm)Power Requirements 100-240VAC, 50-60Hz, 2.1A Regulatory ComplianceGeneral Purpose Medical Device (US only)Ordering Information Infectious Disease Labs Product Size Cat#Maxwell ® 16 Total RNA Purification Kit (1) 48 preps AS1050Maxwell ® 16 Viral Total Nucleic Acid Purification Kit (1) 48 preps AS1150Maxwell ® 16 Tissue LEV Total RNA Purification Kit (1) 48 preps AS1220Maxwell ® 16 Cell LEV Total RNA Purification Kit (1) 48 preps AS1225Maxwell ® 16 SEV Hardware Kit each AS1200Maxwell ® 16 LEV Hardware Kit each AS1250Maxwell ® 16 MDx Instrument SEV (1) each AS3000-SC Maxwell ® 16 MDx Instrument LEV (1) each AS3000-LC Service Products Size Cat#Maxwell 16® Installation and Operation Qualifications each SA1021HLA/Transplant Labs Product Size Cat#Maxwell ® 16 Blood DNA Purification Kit (1) 48 preps AS1010 Maxwell ® 16 Cell DNA Purification Kit (1) 48 preps AS1020Maxwell ® 16 Tissue DNA Purification Kit (1) 48 preps AS1030Maxwell ® 16 Cell LEV DNA Purification Kit (1) 48 preps AS1140Maxwell ® 16 SEV Hardware Kit each AS1200Maxwell ® 16 Tissue LEV Total RNA Purification Kit (1) 48 preps AS1220Maxwell ® 16 LEV Blood DNA Kit 48 preps AS1290Maxwell ® 16 LEV Hardware Kit each AS1250Maxwell ® 16 MDx Instrument SEV (1) each AS3000-SC Maxwell ® 16 MDx Instrument LEV (1) each AS3000-LC Service Products Size Cat#Maxwell 16® Installation and Operation Qualifications each SA1021Pathology Labs Product Size Cat#Maxwell ® 16 Blood DNA Purification Kit (1) 48 preps AS1010 Maxwell ® 16 LEV Blood DNA Kit 48 preps AS1290Maxwell ® 16 Cell DNA Purification Kit (1) 48 preps AS1020Maxwell ® 16 Tissue DNA Purification Kit (1) 48 preps AS1030Maxwell ® 16 Total RNA Purification Kit (1) 48 preps AS1050Maxwell ® 16 FFPE Tissue LEV DNA Purification Kit (1) 48 preps AS1130Maxwell ® 16 Cell LEV DNA Purification Kit (1) 48 preps AS1140Maxwell ® 16 Tissue LEV Total RNA Purification Kit (1) 48 preps AS1220Maxwell ® 16 Cell LEV Total RNA Purification Kit (1) 48 preps AS1225Maxwell ® 16 SEV Hardware Kit each AS1200Maxwell ® 16 LEV Hardware Kit each AS1250Maxwell ® 16 MDx Instrument SEV (1) each AS3000-SC Maxwell ® 16 MDx Instrument LEV (1) each AS3000-LC Service Products Size Cat#Maxwell 16® Installation and Operation Qualifications each SA1021For Laboratory Use.Maxwell is a registered trademark and Personal Automation is a trademark of Promega Corporation.18069。
设计特点、性能约克M AX E YK离心式冷水机组能提供各种形式的配置,以满足不同用户的需要。
彩色图象显示控制中心中国机械安全认证约克M AX E彩色图象显示控制中心,同时显示机组每个部件的运行参数与插图,控制简单形象。
变频配置,高效节能(选项)配置变频驱动器,独特的自适应容量控制将电机变频和导流叶片调节完美地结合在一起,大大提高机组的效率,令部分负荷耗电指标低达0.2kW/ton,机组的年节能可达15%-25%。
配置约克变频驱动装置(VSD)的YK机组机组命名—— YKCFCFQ75CMFYK CF CF Q7 5 CM F设计序号电机代号电源: 5表示50Hz,-表示60Hz压缩机代号冷凝器代号蒸发器代号型号2符合实际工况下的节能要求,机组能充分利用低达12.8℃的冷却水,获得明显的节能效果,而不像有些机组那样需要人为地将水温控制在21~24℃。
高效热交换器,表现卓越热交换器采用了最新的高效换热铜管,使传热效率最佳、结构紧凑。
水侧和制冷剂侧强化传热,减少机组能耗和管道结垢。
结构紧凑,安装方便机组设计精密紧凑,大大减少机房占地面积。
安装时只需少量的接管和布线,帮助用户节约安装费用。
3YK 彩色图象显示控制中心约克彩色图象显示控制中心大大提高了效率且为机组提供了监控、数据记录、安全保护和便利的操作。
该控制中心是当今最先进的微处理器控制系统,由工厂负责安装、敷线和测试。
控制中心有彩色液晶显示屏(LCD )和各界面的轻触式按键。
只需按下单个键就可以显示一系列技术信息和相应部件的彩色图,使信息更清晰明了,使机组操作更便捷。
显示可选择中、英文或其它多种语言。
液晶显示屏所示的图片表现了冷水机组、子系统和系统参数的情况,并可以在同一画面同时显示多个运行参数。
此外,操作员还可以通过图形界面观察冷水机组的历史运行情况和当前运行情况。
在任何时候任何界面都会显示一状态条,它包含了系统状态说明行、详细说明行、控制电源、访问级别、时间和日期。
重庆小时代主要空调设备本项目顶板以上空间比较有限,对于吊挂式空调有它特殊的要求高度不能大于450mm,长度不大于1800mm, 设备噪声要求不得大于60db(A)。
因设计送风出口未设消声器,回风是顶回风方式不接回风箱。
如果噪音超出60分贝空调器前后要增设消声措施。
设备安装在公共区域,走道宽度大都是4000米,其中有消防排烟、电缆桥架、消防管、新风管等。
因此在确认设备厂家时特设定了空调器尺寸噪音等规定,以及回风网要求是4块组成。
约克空调设备噪音值未提供,并且不做非标产品,天加可以生产非标。
本工程空调设计参数机外余压较高,约克空调如按样本所提供的参数有部分产品对本工程所要求不符,天加基本符合。
另外对机组噪音值大于60分贝要增设消声设备,本项目吊式空调较多选用约克会增加安装投资,而选用天加比较符合。
以下是约克和天加空调参数表一、约克空调技术参数及设计参数对照表二、天加空调技术参数及设计参数对照表4N40GDWhen you are old and grey and full of sleep, And nodding by the fire, take down this book, And slowly read, and dream of the soft look Your eyes had once, and of their shadows deep; How many loved your moments of glad grace, And loved your beauty with love false or true, But one man loved the pilgrim soul in you,And loved the sorrows of your changing face; And bending down beside the glowing bars, Murmur, a little sadly, how love fledAnd paced upon the mountains overheadAnd hid his face amid a crowd of stars.The furthest distance in the worldIs not between life and deathBut when I stand in front of youYet you don't know thatI love you.The furthest distance in the worldIs not when I stand in front of youYet you can't see my loveBut when undoubtedly knowing the love from bothYet cannot be together.The furthest distance in the worldIs not being apart while being in loveBut when I plainly cannot resist the yearningYet pretending you have never been in my heart.The furthest distance in the worldIs not struggling against the tidesBut using one's indifferent heartTo dig an uncrossable riverFor the one who loves you.倚窗远眺,目光目光尽处必有一座山,那影影绰绰的黛绿色的影,是春天的颜色。
Histopaque ®-1119Catalog Number 11191Storage Temperature 2–8 °CProduct DescriptionHistopaque ®-1119 is a sterile, endotoxin tested solution of polysucrose and sodium diatrizoate, adjusted to a density of 1.119 g/mL. This ready-to-use medium, when used in conjunction with Histopaque-1077, facilitates the rapid recovery of viable mononuclear cells and granulocytes from small volumes of whole blood.Histopaque-1119 and Histopaque-1077 employ a one-step procedure developed on published observations.1Histopaque-1119 is a sterile solution of polysucrose, 60 g/L, and sodium diatrizoate, 167 g/L. Density: 1.118–1.120 g/mL Endotoxin: ≤ 3 EU/mL pH: 8.8–9.0Reagents and Equipment Required but Not Provided• Histopaque-1077, Catalog No. 10771• Centrifuge (swinging bucket rotor) capable ofgenerating 700 × g• Centrifuge tubes, 15 mL plastic, conical• Isotonic phosphate buffered saline solution orappropriate cell culture mediumPrecautions and DisclaimerFor R&D use only. Not for drug, household, or other uses. Please consult the Safety Data Sheet for information regarding hazards and safe handling practices.Preparation InstructionsSpecimen Collection - Collect blood in preservative-free anticoagulant (EDTA or heparin) or use defibrinated blood. For best results, blood should be processed within 2 hours.Storage/StabilityStore the product at 2–8 °C protected from light.Histopaque-1119 has an expiration period of 3 years. Reagent label bears expiration date.ProcedureA double gradient is formed by layering an equal volume of Histopaque-1077 over Histopaque-1119.Anticoagulated whole blood is carefully layered onto the upper Histopaque-1077 medium. During centrifugation, erythrocytes are aggregated by polysucrose and rapidly sediment. Granulocytes are found at the lowerHistopaque-1077/1119 interface; whereas, lymphocytes and other mononuclear cells are found at the upper plasma/Histopaque-1077 interface. Erythrocytecontamination is negligible. Most extraneous platelets found in the upper interface are removed by low speed centrifugation during washing steps.1. Add 3 mL of Histopaque-1119 to a 15 ml conicalcentrifuge tube.2. Carefully layer 3 mL of Histopaque-1077 onto theHistopaque-1119 and bring to room temperature.3. Carefully layer 6 mL of whole blood onto the uppergradient of the tube from Step 2.4. Centrifuge at 700 × g for 30 minutes at roomtemperature. Centrifugation at lower temperatures, such as 4 °C, may result in cell clumping and poor recovery.Note: Make sure brake and acceleration are on lowest setting on centrifuge, harsh braking and acceleration may affect layer separation.5. Carefully remove centrifuge tubes. Two distinctopaque layers should be observed.6. Aspirate and discard plasma to within 0.5 cm of theupper layer. Transfer cells from this layer to a tube marked “mononuclear”.7. Aspirate and discard remaining fluid to within0.5 cm of the lower layer. Transfer cells from this layer to a tube labeled “granulocytes”.8. Wash the cells by addition of 10 mL of isotonicphosphate buffered saline to the tubes. Centrifuge10 minutes at 200 ×g. Remove the supernatantand discard.9. Resuspend the cells by gently drawing in and out ofa Pasteur pipette.10. Repeat steps 8 and 9 twice.11. Resuspend cells in an appropriate volume ofisotonic phosphate buffered saline solution orappropriate cell culture medium.At this point a variety of assays can be performed. The procedures are chosen according to individual discretion.ResultsErythrocytes should pellet to the bottom of the centrifuge tube.Granulocytes should band at the interface between Histopaque-1119 and Histopaque-1077.Mononuclear cells should band at the interface between Histopaque-1077 and the plasma.If observed results vary from expected results, please contact Sigma-Aldrich Technical Service for assistance. References1. English, D., and Andersen, B.R., Single-stepseparation of red blood cells. Granulocytes andmononuclear leukocytes on discontinuous densitygradient of Ficoll-Hypaque. J. Immunol. Methods, 5, 249 (1974).Histopaque is a registered trademark of Sigma-Aldrich Co. LLC.Ficoll is a registered trademark of GE HealthcareMF,MAM, VNC 04/20-1©2020 Sigma-Aldrich Co. LLC. All rights reserved. SIGMA-ALDRICH is a trademark of Sigma-Aldrich Co. LLC, registered in the US and other countries. Sigma brand products are sold through Sigma-Aldrich, Inc. Purchaser must determine the suitability of the product(s) for their particular use. Additional terms and conditions may apply. Please see product information on the Sigma-Aldrich website at and/or on the reverse side of the invoice or packing slip.。
YAH吊顶风柜2013.11.191.空气处理机组YAH系列约克YAH系列吊顶式空气处理机组是中央空调末端装置。
其功能是对空气进行降温冷却,去湿干燥、加热、等焓加湿、过滤净化以及作为新风机组等。
机组将处理过的空气通过风管送到一定距离的地方,特别适用于小型商业办公大楼和工业应用的空调工程。
约克YAH系列空气处理机组提供10种型号供客户选择,每种型号均有多种排管方式供选择。
冷量从8kW到252kW,风量从1500m³/h到15000m³/h。
约克YAH1.5到06型号机组采用外转子离心式风机,机组全压范围为146-235Pa,YAH1.5到06型号机组采用皮带传动的离心式风机,机组全压范围为180-320Pa。
约克YAH08到15型号采用皮带传动的离心式风机,机组全压范围为275-340Pa。
本系列机组具有安装方便、使用简单、占用建筑面积小、噪声小、冷量大、送风距离远、价格合理等特点。
机组的结构形式为镀锌钢板箱内贴保温棉,机组的结构形式为镀锌钢板箱内贴保温棉,外挂板式尼龙网过滤器。
冷热盘管均采用铜管套双曲波纹片,盘管翅片间距10~12片/英寸,风机和电机,皮带轮均选用优质产品,性能稳定、高效,风机采用双进风离心前倾多翼风机,外转子电机,防护等级IP54,,F级绝缘。
闭式三相异步电机,防护等级IP54,F级绝缘,电源为380V-3-50Hz,轴承无需润滑。
外挂过滤器既可以从侧面取出,也可以从下面取出。
湿膜加湿器为可选项。
机组命名- YAH04 B4LX0D:2.技术规格机组主要技术参数表:YAH-D湿膜加湿器性能参数表:注:1. 湿膜加湿器为等焓加湿过程,仅适用于舒适性空调,不宜用于对湿度有较高精度要求的场合。
2. 当机组配置湿膜加湿器时,机组的机外余压应相应的减去加湿器的风阻。
3. 加湿器新风进风工况: 干球温度28℃,10%RH; 迎面风速小于3.0m/s。
4. 加湿器混合进风工况 (新风比为20-30%): 干球温度28℃,25%RH; 迎面风速小于3.0m/s。
制冷量: 260-415TR高效节能机组特点高效节能综述约克YEWS螺杆式冷水机组完全由工厂组装,包括蒸发器、冷凝器、压缩机、电机、润滑系统、液晶显示微电脑控制中心和整装机组内所有的接管及敷线,并为每台机组提供制冷剂和润滑油的首次充注。
驱动装置选用高效工业用半封闭双螺杆式压缩机,高精度加工,独特结构,高效可靠。
压缩机采用铸铁壳体,锻钢转子,转子间隙很小,但不接触,而支撑面确保转子在各种压力比时,保持精确定位,减少磨损,防止渗漏,延长寿命。
压缩机采用全抗磨轴承设计,减少能耗,提高可靠性。
滚柱轴承受径向载荷四角,滚珠轴承受轴向载荷。
压缩机内部有一个贮油罐,可保证随时向轴承提供润滑油。
止回阀与压缩机框架相结合,可防止转子在停机时逆转。
两极连续运行鼠笼式电机使用吸气冷却(半封闭设计)。
设计工况下的电机满负荷电流不会超过机组的铭牌电流(FLA)。
电机和特定型号的启动器配套使用。
热交换器壳体—蒸发器和冷凝器的壳体由碳钢板卷焊而成。
碳钢管板经钻孔、扩孔接管,焊到壳体端头上。
制冷剂侧的工作压力为1.90MPa,符合国际或中国规范要求。
热交换器采用最先进的高效换热铜管束,内、外壁经强化传热以得到最优的性能。
蒸发器和冷凝器的管束采用了“skip-fin”的设计,支撑处铜管的内外表面光滑。
在支撑部位铜管壁厚加大(壁厚可达原来的两倍),并且未经硬化处理,从而延长了热交换器的寿命。
每根传热管在管板中胀管,以免泄漏;每根管子可以单独更换。
蒸发器—机组采用约克专利的混合降膜式蒸发器技术,制冷剂首先通过喷淋的方式被均匀分配到降膜换热区,自然下降成膜,与换热管间实现膜式换热,其传热系数大大提高。
同时系统所需冷媒充注量明显减少,有助于满足LEED认证的标准。
冷凝器—壳管式,排气经管板反射,防止气体直接高速冲击管束。
也可合理分配制冷剂气体的流量,使换热效率最高。
过冷器位于冷凝器底部,有效地使液体过冷,改善循环效率。
紧凑水室—可拆卸式紧凑水室用钢管制成,设计工作压力1.0MPa。
综合的专业化服务,专为您的业务需求量身定制我们关注您的业务需求,了解每个行业有其独特的要求。
我们全方位的维护服务能满足您在经济和技术方面的所有需求,包括日常设备检查和预测性维护常规工作以及系统性能检测和每年的停工检修等。
3机组命名 - YAH04 B4LX0D空气处理机组YAH 系列约克YAH 系列吊顶式空气处理机组是中央空调末端装置。
其功能是对空气进行降温冷却,去湿干燥、加热、等焓加湿、过滤净化以及作为新风机组等。
机组将处理过的空气通过风管送到一定距离的地方,特别适用于小型商业办公大楼和工业应用的空调工程。
约克YAH 系列空气处理机组提供10种型号供客户选择,每种型号均有多种排管方式供选择。
冷量从8kW 到252kW ,风量从1500m³/h 到15000m³/h 。
约克YAH1.5到06型号机组采用外转子离心式风机,机组全压范围为146-235Pa ,YAH1.5到06型号机组采用皮带传动的离心式风机,机组全压范围为180-320Pa 。
约克YAH08到15型号采用皮带传动的离心式风机,机组全压范围为275-340Pa 。
本系列机组具有安装方便、使用简单、占用建筑面积小、噪声小、冷量大、送风距离远、价格合理等特点。
机组的结构形式为镀锌钢板箱内贴保温棉,机组的结构形式为镀锌钢板箱内贴保温棉,外挂板式尼龙网过滤器。
冷热盘管均采用铜管套双曲波纹片,盘管翅片间距10~12片/英寸,风机和电机,皮带轮均选用优质产品,性能稳定、高效,风机采用双进风离心前倾多翼风机,外转子电机,防护等级IP54,,F 级绝缘。
闭式三相异步电机,防护等级IP54,F 级绝缘,电源为380V-3-50Hz ,轴承无需润滑。
外挂过滤器既可以从侧面取出,也可以从下面取出。
湿膜加湿器为可选项。
4技术规格1. 湿膜加湿器为等焓加湿过程,仅适用于舒适性空调,不宜用于对湿度有较高精度要求的场合。
2. 当机组配置湿膜加湿器时,机组的机外余压应相应的减去加湿器的风阻。