M操作手册版
- 格式:docx
- 大小:174.15 KB
- 文档页数:25
iO-GRID M控制模块操作手册版本历史日期版本内容作者2017/12/29 1.0初版Matthew 2018/01/05 1.1iO-GRID M章节调整Matthew 2018/01/24 1.2Matthew 2018/02/05 1.3参数设定章节调整Matthew 2018/03/09 1.3.1新增异常纪录寄存器位址介绍Matthew目录1.控制模块列表 (4)2.控制模块规格 (5)2.1GFMS-RM01N (5)3.控制模块介绍 (6)3.1控制模块尺寸规格 (6)3.2控制模块面板介紹 (7)4.模块安装拆卸介绍 (9)4.1安装 (9)4.2拆卸 (9)5.iO-GRID M系列介绍 (10)5.1iO-GRID M组件 (10)5.2iO-GRID M接线 (12)5.3iO-GRID M设定接线介绍 (15)6.控制模块参数设定介绍 (16)6.1模块初始设定与设定软件功能 (16)6.2iO-GRID M Utility软件操作步骤 (16)7.控制模块映射寄存器介绍 (23)7.1输入寄存器位址介绍0x1000 – 0x10F6(可读) (24)7.2输出寄存器位址介绍0x2000 – 0x20F6(可读写) (24)7.3异常纪录寄存器位址介绍 (25)7.4支持Modbus function code (25)产品料号产品叙述备注GFMS-RM01N RS485控制模块, RTU/ASCII2.1 GFMS-RM01NTechnical Data模块型别Modbus Master RS485最大扩充模块数247额定电压值5V DC via DINKLE Bus 电流消耗48mA @ 5V指示灯RUN : 绿(电源指示灯)ERR : 红(通信异常指示灯)DI ERR : 红(输入模块异常指示灯) DO ERR : 红(输出模块异常指示灯)Communication Data总线界面RS485 via DINKLE Bus 总线协议Modbus RTU / ASCII鲍率范围1200bps to 1.5Mbps总线接口RJ45*3General Data模块尺寸宽x深x高20 x 100 x 95 mm模块重量Approx. 80 g工作温度0 (55)储存温度-25 (85)相对湿度RH 95%, noncondensing 保护等级IP20产品认证CE3.1 控制模块尺寸规格3.1.1 GFMS-RM01N单位:mm图1控制模块GFMS-RM01N尺寸规格3.2 控制模块面板介紹LED 訊號指示燈RS485#1通訊RJ45接口RS485#2通訊RJ45接口Mini USB 接口,用於設定控制模塊相關訊息: 站號, 鮑率, I/O 模塊參數等。
BATTLE-AX B550M-T PRO V14BATTLE-AX B550M-D PRO V14主板使用手册版本:V2.02022年11月 第一版版权说明本手册版权属于七彩虹公司所有,未经本公司书面许可,任何人不得对此说明书和其中所包含的任何资料进⾏复制、修改、翻译或出版。
免责声明1.本手册上所有图片仅供参考,请以实物为准。
产品信息会依不同国家及地区而有所变动,我们诚挚的建议您与当地的经销商或零售商确认目前销售产品的规格。
2.产品颜⾊可能会因拍照⻆度而与实际产品有所差异。
我们会尽⼒提供正确与完整的数据到网⻚上,并保留随时更正、修改⻚面信息的权利,恕不另⾏通知。
3.为保证用⼾的安全及合法权益,请按照本使用手册操作。
如不遵照本手册规范操作,对此所造成的后果我们不承担任何形式的责任。
4.以上所有产品涉及的其它名称及商标,我们公司拥有最终解释权。
商标版权本手册使用的所有商标均属于该商标的持有者所有。
AMD, Athlon™, Athlon™ XP, Thoroughbred™ 和Duron™是Advanced Micro Devices的注册商标。
Intel® 和Pentium® 是Intel Corporation的注册商标。
PS/2 和OS® 2是International Business Machines Corporation的注册商标。
Windows® 95/98/2000/NT/XP/Vista是Microsoft Corporation的注册商标。
Netware® 是Novell, Inc的注册商标。
Award® 是Phoenix Technologies Ltd的注册商标。
AMI® 是American Megatrends Inc的注册商标。
Kensington和MicroSaver是Kensington Technology Group的注册商标。
宝利通视频会议M C U 系统操作手册公司标准化编码 [QQX96QT-XQQB89Q8-NQQJ6Q8-MQM9N]视频会议系统MCU会议操作手册一、会前准备各分会场应提前开启主会场视频终端电源,检查网络连接情况,电视是否有显示本端会场画面,主屏幕下方是否显示“我的IP地址”。
检查用于MCU操作的电脑是否正常,网终连接是否正常。
二、会议操作1、进入MCU管理界面打开IE浏览器界面,在地址栏输入MCU地址:,回车即可进行MCU的管理员界面,如下图:分别输入用户名和密码后点击登陆;用户名和密码由信息中心统一发放,默认情况下为用户名和密码均为POLYCOM;管理员管理界面介绍:如下图2、新建会议点击会议列表左上方的,出现如下图:点击新建会议后,会出现如下图的对话框,左边是会议属性列表,右边是会议属性的配置选项:“常规”选项:在常规属性里面,可以进行如下配置:会议名称可输入需要召开的会议名称,这名称会在会议中显示出来;会议模板会议模板有832K速率视频会议和1.2 M速率视频会议,如有双流会议,建议先择1.2M速率视频会议模板;会议时长可以定义会议召开的时长,默认为8小时,会议最长不得超过24小时会议号码此号码用于区别不同的会议,供于终端呼入MCU选择需要加入的会议时使用;会议密码设置加入会议的密码;主席密码设置会议主席密码;“与会者”选项:点击“从地址薄添加”,打开地址簿选择与会者;选择与会者;“组播”选项:本属性用于开启会议组播;如需组播,把“启用组播”打勾,把“LAN1”上的勾去掉,把“LAN2“打勾就完成;“信息”选项:本属性用于输入本会议的一些附加说明或计费信息,如无特别说明一般为空;当以上设置完毕时,会议正常召开,整个界面如下图所示;3、会议控制1、邀请与会者:呼叫与会者,从MCU向终端进行呼叫,如下图:2、断开与会者:挂断与会者,把MCU与终端之间的呼叫挂断,如下图:3、静音:在MCU端把下面对应的会场静音(相当于在MCU上关闭与会会场的麦克风,中止该会场的声音发送到MCU)取消静音:关闭该会场的静音功能(相当于打开与会会场的麦克风)4、闭音:在MCU端把下面分会场的音箱关掉(中止MCU把其它会场的声音传送给该会场)取消闭音:关闭掉闭音功能(让MCU把其它会场的声音传送到该会场)4、视频设置如果需要对正在召开的会议进行设置变更,请参照如下详细说明,下图为当前会议界面;如上图,在当前会议名称下(红框部分),鼠标双击或按右键显示菜单选择“属性”,出现会议的属性对话框,显示“常规”情况,会议模板已设定好,无需变更,如下图;“高级”选项,在新建会议时已设定,在会议过程中无需变更,如下图;“视频质量”选项,在新建会议时已设定,对话框里各参数显示灰色状态,在会议过程中无法变更,如下图;“视频设置”选项,可根据开会需要,选择“分屏模式”和多画面显示,如下图;进行视频设置选项,可根据需要在右边选择一种分屏模式;可选择相同分屏和演讲者模式;演讲者模式:所有与会者终端将全屏显示演讲者,而同时演讲者终端将按照此处设定的布局显示其他与会者。
operating manualforSafety-M modulesoperating manual (Vers. 1.-19.12.2007)Important advicetarget audience of this operating manual:maintaineance, replacement, electricians, usersDefinitionsThe synonym Safety-M is used as generic term for all derivates of the Safety-M product line. If the manual points directly to a certain derivate, though the entire term will be used (i.e. Safety-MS2).The following term …safe“ is used for safe function according to the EN 954-1 respectively according to EN 61508 in the particular category or level. Safety Adviceoperating and serviceBefore installation and demounting, or the disconnecting of signal- and power supply cables, the modules has to be de-energized.It has to be avoided to get electrostatics at the terminal blocks and connectors during the dismounting of the Safety-M modules.Guarantee and safety approval is void, if the modules has been manipulated.The Safety-M can only be operated in a temperature range between 0° and 50° C. Make sure that this temperature range will not exceeded.Checking the Certification Code (CRC)Before the normal operation of Safety-M at a machine or plant a safety audit has to be proceeded. As result a test report has to be existent. This report contains a certification code. This code assures that a Safety-M module will be operated with the correct program. By pressing the key “Function” in the normal operation mode …RUN“ (see underneath), the certification code is shown in the 7 – segment display. Compare these displayed numbers (i.e. C 56124) with the numbers of the test report of this particular machine or plant, that they are matching. If these numbers are different, the normal safe operation is not assured. In this case you have to stop the machine or plant at once and contact the company, who installed this machine.modification of an installationThe commissioning or changing of an installation of Safety-M can only achieved by qualified personal! Contact the company, who did the safety related test report. By changing the configuration the safety function of the module can be lost.programming interface7 segment display terminal blocks for input / output signalsLED´s show operating modefunction key for reset and CRC (test report code) encoder interfaceStart up sequencesAfter a start up is initiated, the particular start up phases are shown in the display. If no errors are occurring, the following phases will be passed.7 segment display mode description…1“ STARTUP synchronization, check of configuration- /firmware data…2“ SENDCONFIG synchronization, check of configuration- /firmware data zone check…3“ STARTUPBUSactivate bussystem…4“ RUN normal operating status…5“ STOP only for authorized personal available…A“ ALARM alarm can be reset by pressing the …Function“ key…F“FAILURE Failure can be reset by switching the Safety-M (power supply) OFF and ONLEDcolor mode descriptiongreen …blinking“ system OKyellow …blinking“ get in touch with authorized personalred …blinking“ alarmred …continious“ Fatal Error – Safety-M power supply must be disconnectednotice:Only the operating status 4 = RUN allows after a correct installation of the Safety-M to operate the machine or plant. All configurated safety functions are active. If the Safety-M is in the mode “alarm” = A or in the mode “failure” = F all safety related outputs are deactivated.modification / procedures with changes at the modules or installationrepairRepair of a module could only be achieved in the manufacturer.guaranteeBy changing the Safety-M layout or opening the enclosure the guarantee and safety approval is lost.mechanical modificationThrough modification of drives / mechanical transmission or changing the sensors (encoders) the safety function could be lost. Talk to the company who has installed or delivered the Safety-M modules, or to the person who has created the safety test report.electrical modificationThrough modification the cabling or wiring of the Safety-M modules the safety function could be lost. Talk to the company who has installed or delivered the Safety-M modules, or to the person who has created the safety test report. MaintaineanceExchange of a Safety-M modulAfter a Safety-M module has been changed it has to be assured, that the spare module contains the same configuration. The test report code (check sum / CRC) can be shown in the 7 segment display. It has to be sure, that the these numbers are the same in the test report.Follow the instructions by changing a Safety-M modul•disconnect the drive from the power supply•switch of the power supply of the Safety-M and disconnect ale cables and connections•loosen the connectors of the sensors and pull off•disconnect all further connections•get the Safety-M from the (DIN) rail and pack the Safety-M according to EMC prescriptions•install the new Safety-M at the (DIN) rail•rebuild all connections•switch on the drive•switch on the power supplynote:Basically no pluggable connection of the Safety-M can be disconnected or connected during the voltage is on. Especially the connected speed and position sensors (encoders) could be destroyed.failure modes of the Safety-MIn principle the Safety-M got two different failures according to the followingrelations:failure mode descriptionresult for thesystemreset conditionFatal Errorfatal exceptional error in theinternal program of the Safety-M.A cyclic program flow is not morepossible. The last active processis to operate the segment displayby system A. System B hasstopped.All outputs will bedisconnected - shutdown!Only resettable byswitching off thepower supply ofthe Safety-M(POR).Alarm functional failure, caused by aninternal process. Both systemswill still run in the cyclic processand handle all requirements ofthe communication interfaces.All outputs will bedisconnected - shutdown!Reset by the pre –defined reset inputIf an alarm or fatal error occurs more often, then contact the company who has installed the machine or plant.。
维修及操作和维修手册(O&M手册)一、维修1.在缺陷责任期内,承包人应免费进行日常的维修工作。
2.所有设备应便于检查、清洁、更换和维修。
设备中相同的部件应具有互换性,设备的互换性应在操作与维修手册中详细描述。
设备的部件(包括印刷电路板等级)应清楚标明组装号、序列号和变更等级。
在进行完工测试时,承包人应给业主代表和监理工程师提供组装件安装在各种设备里的位置记录表。
这种记录表被认为是完工图纸的一部分将用作维修及可靠性评价的基础数据。
设备各部分之间要有可靠的绝缘,这样在维修其中一部分时将不影响其它部分的工作。
二、操作和维修手册(O&M手册)(一)概述1、在系统试运转开始之前1个月内,承包人应提交2份操作和维修手册(初稿)给业主。
并在缺陷责任期开始后不迟于6个星期提交6份操作和维修手册正式稿给业主,但是有些设备的技术资料应事先提供,O&M手册中的重要部分应用中文编写。
2、每种设备应提供2份专用设备手册。
专用设备手册是缩略本,应尽量减少无关的内容,并有详细说明,便于参照使用。
3、操作和维修手册中应对各系统的运行操作做出全面的详细说明。
4、对于系统中的某些设备或部件,如印刷电路板,承包人可直接使用这些设备与部件的生产厂家的资料和手册作为本操作维修手册的一部分,并根据手册的总目录依次汇编,这种文件可保留原有封面。
5、有些设备或部件在本地无法维修,必须送到厂家维修,那么,在O&M手册中应包括这些设备或部件的维修和拆装资料。
6、控制原理图要清楚表示出设备的操作、安装及各部分的连接和各部分间电缆的走向。
全部控制原理图包括部件、接触器的说明、图例和附注,即电流范围、线圈电压等等及继电器的动作线圈、特殊功能的恰当说明。
7、O&M手册应有目录表和专门术语(编写)的章节,为了使用户容易理解O&M手册的内容,应在手册中包括所需的框图、图纸、轮廓图和实际设备或系统的照片,同时,还应包括操作使用该设备的注意事项和设备的安全使用寿命。
Products Solutions Services操作手册RMx621/FML621PROFINET 模块(“PROFINET 耦合器”),自V3.03.01版本起通过带外部模块(用于PROFINET 设备的HMS AnyBus 通信器)的串行RS485接口,将RMx621/FML621连接到PROFINETBA02024R/28/ZH/01.20714894782020-02-28RMx621/FML621目录目录1概述 (4)1.1运输中损坏 (4)1.2供货清单 (4)1.3安全图标 (4)1.4特定信息图标 (4)1.5图中的图标 (5)1.6缩略语列表/术语定义 (5)2安装 (6)2.1功能描述 (6)2.2要求 (7)2.3连接和操作元件 (7)2.4安装在DIN导轨上 (7)2.5连接和端子图 (8)2.6PROFINET针脚分配 (8)3调试 (9)3.1RMx621/FML621的设置 (9)3.2设置PROFINET耦合器 (10)3.3设备命名规则 (14)3.4状态标识 (14)4过程数据 (16)4.1概述 (16)4.2有效载荷结构 (16)5集成至PROFINET网络 (17)5.1设备接入点(DAP) (17)5.2模块 (17)5.3映射过程数据 (17)6在TIA Portal 15.1中配置PROFINET耦合器 (21)6.1导入GSDML文件 (21)6.2集成PROFINET耦合器 (22)6.3分配设备名和IP配置 (23)6.4设置输入模块 (26)6.5将配置下载到PROFINET控制器 (26)7技术参数 (29)Endress+Hauser3概述RMx621/FML6211 概述1.1 运输中损坏请立即通知货运代理和供应商。
1.2 供货清单•操作手册•用于PROFINET设备的PROFINET模块HMS AnyBus通信器•至RMx621/FML621的串行连接电缆•带GSDML文件和位图的CD-ROM如果缺少任何零件,请立即通知供应商!1.3 安全图标1.4 特定信息图标4Endress+HauserRMx621/FML621概述1.5 图中的图标1.6 缩略语列表/术语定义PROFINET耦合器在下文中,术语“PROFINET耦合器”表示用于PROFINET设备的外部PROFINET模块HMS AnyBus通信器。
* ‘后续’键:用于向后翻查显示,可单步地也可连续多步。
* ‘上翻'’键:用于向前翻查显示,可单步执行也可连续多步。
* ‘退出’键:用于从当前命令状态退出或结束。
* ‘快速进入’键:用于快速方式进入功能子菜单。
先按该键,再输入一个四位数,之后按‘确认/进入’键,可直接找到所需子菜单。
MINERVA-80控制盘要先按入密码方可使用。
密码根据便用人员的职责、工作范围分多个级别 :二个级对用户开启,多个级对设计人员开放,用户使用等级可
分为用户操作人员、经理,后者有较高的使用等级。
每个等级可预设多个密码。
进入系统后,MINERVA-80提示一个主菜单,用户可以根据菜单提供选择要检查的项目,然后按‘YES’键进入子后的之菜单逐层的寻找,键入自己的选择
项,直至查到所需的材料。
由于使用菜单方式,用户自己键入数据不多主要是选
择‘是’ ‘否’。
为了快速寻找某个功能,可以用‘FAST ACCESS’键,在键
入一个4位码便可以直接进入了一个功能项。
11.2.1 正常状态
盘启动后显示
上电过程结束后,如正常情况,没有任何事故发生的话,只显示
时间、日期。
11.2.2 事件显示按照发生时间顺序成优先权顺序
事件的优先权顺序如下:
1)第一个全面报警或示警告
2)所有其它的全面报警或示警
3)从上次复位开始后,第一个故障
4)所有以上次复位开始的故障
5)第一个预警告
6)以上次复位后,所有其它的警告
当事件发生后,事件自动记录在事件记录表内。
事件记录表分
在主菜单中选择查看记录子菜单即快速码为0010时菜单显示如下﹕
11.3.3.2.2 先显示最早发生的事件
当选择这个子菜单时,事件记录内容将按事件发生的时间顺序以逐个显示。
事件显示按下列模式﹕
系统重启
0 号逻辑区
12:00:19 28 Jan
SUP LBO S2
注意﹕显示屏底行显示事件的系统绝对地址,按‘下翻’可查后面的记录,‘上翻’,可查前面的记录,"事件记录到记录开始或记录结束时,显示如下﹕
记录底部 !
且内部峰鸣器将响二声,按‘退出’可以退出该功能。
11.3.3.2.3 先显示最新发生的事件
当选择这个子菜单时,事件记录内容将按逐事件发生时间顺序从新向旧逐
个显示。
事件显示模式如前。
按键操作用11.3.3.2.2所述。
11.3.3.2.4 先显示最高优先权事件
当选择这个子菜单时,事件记录将按下列优先权次序显示﹕
﹒火警(疏散)
﹒火警(警报)
﹒故障(系统)
﹒故障(地址码)
﹒故障(清除)
﹒警告
﹒复位/清音
﹒打印机输出脱线
事件显示及按选择操作如11.3.3.2.2段所述,按‘退出’可以退出该功
能。
11.3.3.3 查看系统状态菜单
11.3.3.3.1 菜单选择
在主菜单中选择查看系统状态时,显示屏时显示如下:
本段中分区故障和分区隔离显示是最重要的,其余的部分起辅助完善作用。
11.3.3.3.2 查看分区报警状态
当选择快速码为 0101的子菜单时可以查看80每个分区的有无火警状态。
第一个模式如下:
隔离点 02﹕24﹕22 01 Jan 93
A 2
系统隔离所有区 02﹕24﹕22 01 Jan 93
Non Addressable Pnt.
隔离警告一区 02﹕24﹕22 01 Jan 93
Zone 01 A 3
隔离点所有区 02﹕24﹕22 01 Jan 93
A 3
11.3.3.7 恢复菜单
11.3.3.7.1 菜单选择
在菜单中选择该功能,将可以恢复被隔离的设备(即可以产生报警响应)。
11.3.3.7.2 恢复分区(只含探测器)
当选择该功能,以前被隔离的某区内探测器可以被恢复,程序如下:
a) 以上菜单选择‘恢复分区’ ﹐显示如下﹕
区域号 :
(是=全部)
b) 输入所需分区号,再按‘确认/进入’,控制盘显示﹕
成功
恢复
如果再没有被隔离点或分区时,隔离灯灭﹐内部蜂鸣器不再响。
如果有被隔。