70246-4021;中文规格书,Datasheet资料
- 格式:pdf
- 大小:170.65 KB
- 文档页数:3


GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.©2007 by Honeywell International Inc. All rights 9021-60292 Rev. A page 1 of 2Flex Series GWF402 andGWF4042 and 4 Zone ConventionalFire Alarm Control PanelsSIGNALINGS521MEAApprove d366-04-E 7165-1288:180An ISO 9000-2000 CompanyDescriptioni 3™ is a trademark of Honeywell International Inc.UL ® is a registered trademark of Underwriter’s Laboratories Inc.The Flex 402 is a two zone fire alarm control panel (FACP)and the Flex 404 is a four zone FACP . These control pan-els provide reliable fire signaling protection for small to medium sized retail, office, multi-family, or other similar commercial or institutional building. Initiating device circuits (IDCs) for Flex Series panels are power limited and operate in Style B (Class B). Each panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull sta-tions, water flow devices, tamper switches and other nor-mally-open contact devices. This includes System Sensori 3™ Series microprocessor-based detectors with advancedfeatures like drift compensation, maintenance alert and freeze warning. (See Device Compatibility Document PN 52195 for a listing of compatible devices.)Outputs include one notification appliance circuit (NAC) on the Flex 402 and two NACs on the Flex 404. NACs are power limited and operate in Style Y (Class B). Each FACP has a Form-C Alarm and Trouble relay and 24 VDC special applications resettable power. In addition, the Flex 404 has a Form-C Supervisory relay and a special application non-resettable power output. The FACP supervises wiring, AC voltage and battery level.Activation of a compatible smoke detector or any normally-open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED,sound the piezo sounder at the FACP , activate the FACP alarm relay and operate and optional modules used to notify a remote station or initiate an auxiliary control function.Both the Flex 402 and Flex 404 fire alarm control panels are listed to UL ® Standard 864, 9th Edition.Features•Flex 402: Two Style B (Class B) IDC zones, one Style Y (Class B) NAC•Flex 404: Four Style B (Class B) IDC zones, two Style Y (Class B) NACs•Optional NAC Class A converter module (Flex 404)•NAC synchronization and programmability features:- ADA compliant strobe synchronization- ANSI audible signals as required by NFPA 72- Silence inhibit, auto-silence, non-silenceable - Selective Silence: mute horns, keep strobes lit - Temporal or steady signal•Silent or audible walk test from front keypad•Zone disable, alarm verification selectable per zone •Controls: Acknowledge, Alarm, Silence, Reset, Walktest, Zone enable/disable•LED indicators: Alarm, Supervisory, Maintenance, Trouble (one per zone): AC, NAC / Zone disable, NAC fault, System / Power Trouble, Walktest, Alarm Silence, Charger / Battery / Earth Fault (on pcb) •Alarm verification•Low AC voltage sense, automatic battery charger •Piezo sounder for alarm, trouble, and supervisoryGWF402 (left) and GWF404 (right)GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189021-60292 Rev. A page 2 of 2 OptionsCAC-4Used to convert Style B (Class B) IDCs toStyle D (Class A) and Style Y (Class B) NACs to Style Z (Class A). Mounts inFACP . Flex 404 only.XRM-24Second 100VA transformer for maximumaccessory power. Mounts in FACP . Flex 404 only.4XTMF Transmitter module provides output forlocal energy municipal box transmitter and alarm and trouble reverse polarity. Mounts in FACP . Flex 402 & Flex 404.4XZMF Zone relay module provides Form-C relays:Alarm Zones 1, 2, 3, 4, System Alarm, Trouble. Mounts in FACP . Flex 404 only.4XLMF LED interface module supports theGWSAN-404 remote annunciator,supervises annunciator wiring for open conditions. Mounts in FACP . Flex 404 only.411UD Four input/channel, dual line, digital alarmcommunicator/transmitter(DACT). Input/channels are compatible with normally open relay contacts, are supervised and fully programmable. Interfaces with public switched telephone networks andcompatible with most central station receiv-ers. Flex 404 only.GWSAN-404Remote annunciator mounts in single-gangelectrical box, provides LED indication of Alarm Zones 1, 2, 3, 4; and System Trouble. Flex 404 only.SpecificationsAC Power 120 VAC, 50/60Hz, 2.3 ABatteryMax. charging circuit: 27.6 VDC@ 0.8A Max. charger capacity: 18 Ah (two 7Ah batteries fit inside FACP)Initiating Device Alarm zones 1 & 2 (Flex 402 / Flex 404)Circuits (IDC)Alarm zones 3 & 4 (Flex 404 only)Operation: All zones Style B (Class B)Power limited circuitryOperating voltage: nominal 20 VDC Alarm current: 15 mA minimumShort circuit current: 40 mA maximum Standby current: 4 mAMaximum loop resistance: 100 ohms NotificationOne NAC: Flex 402; two NACs:Flex 404Specifications (Continued)Circuits (NAC)Operation: Style Y (Class B)Power limited circuitryOperating voltage: nominal 24 VDC Maximum signaling current: 2.5 A total (5.0 A Flex 404 with optional transformer)Maximum line impedance: 1.5 volt dropForm-C Relays Trouble, Alarm (Supervisory, Flex 404)Contact ratings 2 A @ 30 VAC (resistive)Resettable Operating voltage: nominal 24 VDC powerPower limited circuitryMaximum available current: 500 mANonresettable Operating voltage: nominal 24 VDC power Power limited circuitryMaximum Available current: 500 mA CabinetDoor: 15.3" x 14.7" x 0.3" (39 x 37 x 1 cm)Backbox: 15.0" x 14.5" x 3.0"(38 x 37 x 8 cm)Ordering InformationGWF402Flex 402 conventional FACP , 2 zones, 120 VAC, redGWF404Flex 404 conventional FACP , 4 zones, 120 VAC, red71252EOL resistor, 4.7K ohm, ½ watt52194Flex 402 and Flex 404 Installation & Operation ManualOptions:CAC-4Class A converter for initiating device circuits and notification appliance cir-cuits (cannot be used on Flex 402)XRM-24Transformer, expands NAC circuit power from 3 to 5 amps4XTMF Transmitter module for remote station output or municipal box connection 4XZMF Relay module, four relays-by-zone, alarm and trouble contacts, 24VDC 4XLMF Remote annunciator driver, 24 VDC, supports GWSAN-404411UDFour channel dual slave programmer DACT, Form C relay and upload/down-load capability; with enclosure, requires PRO-411PRO-411Programmer, use with 411UD, 411UDACGWSAN-404LED remote annunciator for Flex 404, 4 alarms, 1 trouble (requires 4XLMF)BB-17FBattery box, houses 2 batteries (7-18 Ah max)。
Chemlok® 402X Technical Data SheetChemlok® 402X is a solvent-based, one-coat surface treatment for affixing textiles to a wide variety of unvulcanized elastomers. Chemlok 402X is an all-xylene version of Chemlok 402. It is composed of a mixture of polymers, organic compounds and fillers dissolved or dispersed in an organic solvent system.Chemlok 402X is used in the production of hoses, belts, diaphragms and other textile-reinforced rubber products. It can also be used as an additive to tie cements, as a replacement for isocyanates that are widely used in rubber/ textile bonding.Features and Benefits:Versatile – affixes a variety of elastomers to a wide variety of textiles, including polyester, polyamide, cotton, rayon, and polyaramid.Non-chlorinated Solvent System – suitable for solvent incineration, saving cost of recovery equipment. Excellent Performance – works well on RFL-treated fabric or cord. Fabric or cord treated with Chemlok 402X can be used in process once Chemlok 402X film is tack-free.Convenient – requires only a single coat for most applications, reducing labor, solvent usage, inventory and shipping costs.Elastomers:• Natural Rubber (NR) • Polychloroprene (CR)• Polyisoprene (IR) • Nitrile (NBR)• Styrene-butadiene (SBR) • Butyl (IIR)• Polybutadiene (BR)Application:Mixing – Thoroughly stir Chemlok 402X before use, and agitate sufficiently during use to keep dispersed solids uniformly suspended. If dilution is needed, use xylene or toluene. Note proper dilution for the various application methods is best achieved by experience. Give careful attention to agitation since dilution will accelerate settling. Applying – Apply Chemlok 402X by dip, brush or spray methods. For most applications, 6-10% dry weight pickup is necessary. To optimize both performance and flexibility, apply Chemlok 402X to the fabric at a level just high enough to meet performance specifications.For affixing specialty elastomers such as EPDM and epichlorohydrin, Chemlok 402X should be topcoated with another specialty covercoat designed for that specific elastomer. Using this method helps ensure strong cohesive strength of the system.Drying/Curing – Allow Chemlok 402X to dry until the coated fabric is tack-free and visual examination of the film has shown that all solvent has evaporated. This will take approximately 30-60 minutes at room temperature. Drying time can be shortened by oven drying for 10-15 minutesat 65°C (150°F). Higher temperatures may be used to reduce drying times, but care must be taken to ensure that excessive heat does not cause adverse effects. Shelf Life/Storage:Shelf life is nine months from date of shipment when stored by the recipient in a well ventilated area at 21-27°C (70-80°F) in original, unopened container. Do not store container outside.Chemlok 402X is moisture sensitive. Minimize exposure to moisture by preparing only what is needed for several hoursof use.Chemlok 402X — Technical Data SheetParker LORDEngineered Materials Group 111 LORD DriveCary, NC 27511-7923USAValues stated in this document represent typical values as not all tests are run on each lot of material produced. For formalized product specifications for specific product end uses, contact the Customer Support Center.Information provided herein is based upon tests believed to be reliable. In as much as Parker LORD has no control over the manner in which others may use this information, it does not guarantee the results to be obtained. In addition, Parker LORD does not guarantee the performance of the product or the results obtained from the use of the product or this information where the product has been repackaged by any third party, including but not limited to any product end-user. Nor does the company make any express or implied warranty of merchantability or fitness for a particular purpose concerning the effects or results of such use.WARNING — USER RESPONSIBILITY . FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.©2021 Parker Hannifin - All Rights ReservedInformation and specifications subject to change without notice and without liability therefor. Trademarks used herein are the property of their respective owners.OD DS6034CE 04/21 Rev.1Cautionary Information:Before using this or any Parker LORD product, refer to the Safety Data Sheet (SDS) and label for safe use and handling instructions.For industrial/commercial use only. Required to use under organized emissions. Must be applied by trained personnel only. Not to be used in household applications. Not for consumer use.Chemlok® 402X是一种溶剂型单涂,设计用于帮助和促进纺织品附着于各种未固化的弹性体。