UK 14,304 tartrate_70359-46-5_DataSheet_MedChemExpress
- 格式:pdf
- 大小:103.62 KB
- 文档页数:1
MARKETING NAME*: Dell EqualLogic PS6100X, PS6110X Dell Inc. REGULATORY MODEL: E04J REGULATORY TYPE: E04J001EFFECTIVE DATE: August 18, 2011TABLE OF CONTENTS FOR PRODUCT SAFETY, EMC & ENVIRONMENTAL DATASHEETRegulatoryI. Product SafetyII. Electromagnetic CompatibilityIII. Ergonomics, Acoustics, and Hygienics IV. Power Cords and User Documentation V. Datasheet Responsible Party Name and AddressVI. Trade Import/Export Compliance Data Environmental VII. System Dimension and WeightVIII. Declarations and CertificationsIX. Performance DataX. Product Materials InformationXI. PackagingXII. BatteriesXIII. Design for EnvironmentXIV. Recycling/End-of-Life Service Information XV. Dell Corporate Environmental InformationI. PRODUCT SAFETY1The product has been certified and bears the Mark, as applicable, of the Product Safety authorities as indicated below.Country/Region Authority or MarkArgentina IRAMBelarus BELLISCanada SCCCroatia KONCAREuropean Union CEGermany TUVSUDIECEE IECEE CBIsrael SIIKazakhstan OTAN–CKTKenya KEBSKuwait KUCASMexico NYCE (NOM)Moldova INSMNigeria SONCAPNorway NEMKORussia GOSTSaudi Arabia KSA ICCPSerbia KVALITETSouth Africa NRCSTaiwan BSMIUkraine UKRTESTUnited States NRTLUzbekistan STZ* Notice: This product has been assigned a unique regulatory model and regulatory type that is imprinted on the product shipping invoice and product labeling to provide traceability to the regulatory approvals noted on this datasheet. This datasheet applies to any product that utilizes the assigned regulatory model and type including marketing names other than those listed on this datasheet. Requests for specific information on product regulatory approvals should reference the assigned product regulatory model and type.1 The above-listed Product Safety certifications may vary depending upon the location of the factory and specific product configuration. Certification marks may not be applied on products for countries outside the purchaser’s country.II. ELECTROMAGNETIC COMPATIBILITY2The product has been certified and bears the Mark, as applicable, of the EMC authorities as indicated below.Country/Region Authority or Mark Class Australia / New Zealand ACMA (C-Tick)Class ABelarus BELLIS Class ABosnia & Herzegovina, Montenegro, Serbia KVALITET Class ACanada ICES Class ACroatia KONCAR Class AEuropean Union CE Class AIsrael SII Class AJapan VCCI Class A–CKT Class AKazakhstan OTANMoldova INSM Class ANorway NEMKO Class ARussia GOST Class ASouth Africa SABS Class ASouth Korea KC Class ATaiwan BSMI Class AUkraine UKRTEST Class AUnited States FCC Class AUzbekistan STZ Class AIII. ERGONOMICS, ACOUSTICS AND HYGIENICS3The product has been certified and bears the Mark, as applicable, of the Ergonomics, Acoustics and Hygienics authorities as indicated below.Country/Region Authority or MarkGermany GSIV. POWER CORDS AND USER DOCUMENTATIONDell products are provided with the power cord and user documentation suitable for the intended country of delivery. Products that are relocated to other countries should use nationally certified power cords and plugs to ensure safe operation of the product. Contact Dell to determine if alternate power cords or user documentation in other languages is available for your market.V. DATASHEET RESPONSIBLE PARTY NAME AND ADDRESSDell Inc.Department: Global Regulations and StandardsMS: PS4-30Round Rock, Texas 78682, USA******************************2 The above-listed EMC certifications may vary depending upon the location of the factory and specific product configuration. Certification marks may not be applied on products for countries outside the purchaser’s country.3 The above-listed Ergonomics, Acoustics and Hygienics certifications may vary depending upon the location of the factory and specific product configuration. Certification marks may not be applied on products for countries outside the purchaser’s country.VI. TRADE (IMPORT/EXPORT) COMPLIANCE DATAFor any questions related to importing & exporting classification of Dell products, please obtain information from the following link: /import_export_compliance or send request to*****************************VII. SYSTEM DIMENSION AND WEIGHTDepth, mm Width,mmHeight,mmWeight, kgProductRegulatoryModel #508 446 87 23.31 E04JVIII. DECLARATIONS AND CERTIFICATIONSThis system received the following approvals and may be labeled with one or more of these marks depending on point of purchase:Dell’s Energy Star qualified products are listed on the EPA website hereInformation on Dell’s participation in various Eco-labels and Green Standards can be found here.IX. PERFORMANCE DATAEnergy Consumption4Energy efficiency benefits the environment and lowers the total cost of equipment ownership by reducing power consumption. Dell offers energy calculators that help estimate power needs, potential emissions avoidance and potential cost savings. Click here for Dell’s Client Energy Savings Calculator, Data Center Capacity Planner, and Monitor Power Savings Calculator. Information on Energy Efficiency is available hereX. PRODUCT MATERIALS INFORMATION5Dell has implemented process controls and corrective actions throughout its organization and supply chain to ensure that its chemicals management objectives are met — and that the targeted restricted materials arereplaced and alternative materials are developed for future product generations. Process controls that Dellimplemented include piece-part supplier declarations and Dell factory and supplier material testing audits.To review Dell’s Restricted Material Guidance document click here.Information on Dell’s material use is available here.4 This document is informational only and reflects laboratory performance. Your product may perform differently, depending on the software, components and peripherals you ordered. Accordingly, the customer should not rely upon this information in making decisions about electrical tolerances or otherwise. No warranty as to accuracy or completeness is expressed or implied.5Waste Handling. Local regulations should be observed when disposing of this product due to the presence of the materials and substances as listed above.Restricted SubstancesThrough internal design controls and supply chain declarations, this system has been verified to comply with the EU RoHS Directive. For more details, see /rohsinfo.All Dell products shipping directly into China which are manufactured on or after March 1st, 2007, will be China RoHS compliant. For more details, see /chinarohs.All Dell products shipping to South Korea are compliant with South Korea RoHS requirements, declarations here. Information on Japan RoHS (J-MOSS) chemical disclosures is available here.REACH (Registration, Evaluation, Authorization and Restriction of Chemicals, 1907/2006) is the European Union’s (EU) chemical substances regulatory framework. Dell complies with the REACH directive. For more details, see /REACHThis Dell product does NOT contain any of the following substances (in concentrations exceeding legal threshold limits):∙ Asbestos∙Azo dyes/colorants in components that come into direct contact with human skin∙Cadmium and its compounds (except for use in applications exempted by the EU RoHS Directive)∙Ozone Depleting Substances; Class I and Class II CFCs (chlorofluorocarbons) and HCFCs (hydrofluorocarbons)∙Chloroparaffins, short chained (10-13 carbon chain)∙Chromium VI and its compounds (except for use in applications exempted by the EU RoHS Directive)∙Halogenated dioxins or furans (i.e. polychlorinated dibenzodioxines, polychlorinated dibenzofurans)∙Lead and its compounds (except for use in applications exempted by the EU RoHS Directive)∙Mercury (except for use in applications exempted by the EU RoHS Directive)∙Nickel and its compounds in components that are likely to result in prolonged skin exposure(polychlorobiphenyls)∙ PCBs(polychloroterphenyls)∙ PCTs(polybromobiphenyls)∙ PBBs∙PBDEs (polybrominated diphenylethers)∙BFR (brominated flame retardants) and PVC (polyvinyl chloride) in plastic parts greater than 25 grams ∙Polychlorinated naphthalenes (PCNs)∙Tributyl tin (TBT)∙Triphenyl tin (TPT)Additional Materials Information∙External and/or Internal cables may use PVC as an insulating material to ensure product safety∙The case material is, >PC+ABS <∙Product may contain post-industrial recycled content (plastics, metal, glass)∙This product contains 0% post-consumer recycled plastic∙Materials that may require special handling, please see WEEE Product End-of-Life Instructions here∙Marking of plastic parts greater than 25 grams are done in accordance with ISO 11469 (see below) Flame Retardants Used in MotherboardRetardantPart FlameMotherboard TBBPAFlame Retardants Used in Mechanical Plastic Parts > 25 gramsResin MaterialName Marking perISO11469:2000,11469:1996Flame RetardantMarking per ISO1043-4 (i.e. FR(16),FR(40), etc.)Flame Retardant(i.e. TBBPA, triarylphosphate ester,etc.)List applicableR-Phrase(s) orHazardStatement(s) perEU Directive67/548/EEG or1272/2008PC+ABS >PC+ABSFR(40)<FR(40)TPP(Triphenyl phosphate)N/AXI. PACKAGINGInformation on Dell’s sustainable packaging effort available here.No CFCs (chlorofluorocarbons), HCFCs (hydrofluorocarbons) or other ozone depleting substances are used in packaging material. Chromium, lead, mercury, cadmium are not intentionally added to packaging materials and are not present in a cumulative concentration greater than 100 ppm as incidental impurities. No halogenated plastics or polymers are used for packaging material. Dell complies with the EU Directive 94/62/EEC. Plastics packaging materials marked according to SPI (Society of Plastics Industry) Coding System.Additional materials restricted in Packaging as per Dell’s Restricted Material Guidance document found here.Packaging Materials for ModelE04J Total Weightof eachMaterialtype, (kg)% of Post-Consumer Recycled Content (PCR)APJ region DAO region EMEA regionCorrugated Fiberboard 5.80EPE 1.20Printed user documentation is bleached in a chlorine-free process.XII. BATTERIESBelow is a listing of batteries that could be present in the product:Battery Description – Internal Batteries Battery Type Battery Weight (kg) CR-2032 coin (button) cell Lithium Metal 0.003 ∙Batteries used in this product are in compliance with EU Battery Directive 2006/66/EC.∙Batteries in this product are not based on mercury, lead or cadmium technologies.∙Information about takeback and the recycling of batteries can be found in the in the Recyclability section below.∙The product documentation includes instructional information on the proper removal and disposal of the batteries used in this product.∙Dell MSDS sheets available here.XIII. DESIGN FOR ENVIRONMENTandUpgradingLongevityDell systems are, when applicable, designed for easy assembly, disassembly, and servicing. Connections are easy to find and accessible with commonly available tools. To extend the life of your system, you can install or upgrade certain system components (e.g., microprocessor, memory, expansion cards, optical drives, and storage devices). Spare parts (such as batteries, power supplies, keyboard parts) are available after the end of production for up to five years, or otherwise through the warranty period.RecyclabilityInformation for recycling is available here.For recyclability, this system incorporates the following design guidelines:∙EU WEEE mark is applied to products sold in Europe, EU recycling information can be found at /recycling∙WEEE Product End-of-Life Instructions are available here∙Plastic parts heavier than 25g have material codes according to ISO 11469:2000.∙Minimal use of composite structure materials.∙Minimal use of non-separable connections, such as gluing and welding between different materials∙Painting/coating of plastics <100 grams is compatible with recycling or reuse∙Mechanical plastic parts greater than 100 grams consist of one material or of easily separable materials.XIV. RECYCLING/ END-OF-LIFE SERVICE INFORMATIONTake back and recycling services are offered for this product in certain countries. If you want to dispose of system components, contact Dell for instructions by emailing *********************** or visit/recyclingworldwide and select the relevant country.XV. DELL CORPORATE ENVIRONMENTAL INFORMATIONInformation on Dell’s Environmental initiatives, policies, programs and goals can be found at/environment.Dell’s Corporate Responsibility Policies are available here.Product Safety, EMC and Environmental Datasheets for Dell products are located at:/regulatory_compliance_datasheetsDell is a member of the Electronic Industry Citizenship Coalition ()Dell’s commitment to accountability and assurance is further demonstrated in leveraging the Global Reporting Initiatives (GRI) G3 Guidelines in the preparation of our annual summary report and Web site. We are self-reporting at a B level and have submitted our self-report to GRI to check it against the criteria for GRI Application Level B. To view GRI Index 2009 click here.Dell holds International Organization for Standardization (ISO) and Occupational Health & Safety Assessment Series (OHSAS) certifications/registrations in a number of important areas including global product development and recycling/take-*back programs, quality, safety, and health and environment. You can view or download copies of certificates here.Information related to Supplier Responsibility is available here.。
RVN4126 3.59100-386-9100-386/T DEVICERVN41772-CD2-3.5MCS/MTSRVN41821-CD2-3.5XTS3000/SABER PORTABLE YES RKN4046KHVN9085 3.51-20 R NO HLN9359 PROG. STAND RVN4057 3.532 X 8 CODEPLUG NO3080385B23 & 5880385B30 MDVN4965 3.59100-WS/T CONFIG KITRVN4053 3.5ASTRO DIGITAL INTERFACE NO3080385B23RVN41842-CD RKN4046A (Portable) 2-3.5ASTRO PORTABLE /MOBILE YES3080369B73 or0180300B10 (Mobile) RVN41831-CD3080369B732-3.5ASTRO SPECTRA MOBILE YES(Low / Mid Power)0180300B10 (High Power) RVN4185CD ASTRO SPECTRA PLUS MOBILE NO MANY OPTIONS; SEESERVICE BRIEF#SB-MO-0101RVN4186CD ASTRO SPECTRA PLUS MANY OPTIONS;MOBILE/PORTABLE COMB SEE SERVICE BRIEF#SB-MO-0101RVN4154 3.5ASTROTAC 3000 COMPAR.3080385B23RVN5003 3.5ASTROTAC COMPARATORS NO3080399E31 Adpt.5880385B34RVN4083 3.5BSC II NO FKN5836ARVN4171 3.5C200RVN4029 3.5CENTRACOM SERIES II NO VARIOUS-SEE MANUAL6881121E49RVN4112 3.5COMMAND PLUS NORVN4149 3.5COMTEGRA YES3082056X02HVN6053CD CT250, 450, 450LS YES AAPMKN4004RVN4079 3.5DESKTRAC CONVENTIONAL YES3080070N01RVN4093 3.5DESKTRAC TRUNKED YES3080070N01RVN4091 3.5DGT 9000 DESKSET YES0180358A22RVN4114 3.5GLOBAL POSITIONING SYS.NO RKN4021AHVN8177 3.5GM/GR300/GR500/GR400M10/M120/130YES3080070N01RVN4159 3.5GP60 SERIES YES PMLN4074AHVN9128 3.5GP300 & GP350RVN4152 3.5GP350 AVSRVN4150 3.5GTX YES HKN9857 (Portable)3080070N01(Mobile) HVN9025CD HT CDM/MTX/EX SERIES YES AARKN4083/AARKN4081RiblessAARKN4075RIBLESS NON-USA RKN4074RVN4098H 3.5HT1000/JT1000-VISAR YES3080371E46(VISAR CONV)RVN4151 3.5HT1000 AVSRVN4098 3.5HT1000/ VISAR CONV’L.YES RKN4035B (HT1000) HVN9084 3.5i750YES HLN-9102ARVN4156 3.5LCS/LTS 2000YES HKN9857(Portable)3080070N01(Mobile) RVN4087 3.5LORAN C LOC. RECV’R.NO RKN4021ARVN4135 3.5M100/M200,M110,M400,R100 includesHVN9173,9177,9646,9774YES3080070N01RVN4023 3.5MARATRAC YES3080070N01RVN4019 3.5MAXTRAC CONVENTIONAL YES3080070N01RVN4139 3.5MAXTRAC LS YES3080070N01RVN4043 3.5MAXTRAC TRK DUPLEX YES3080070N01RVN4178CD MC SERIES, MC2000/2500DDN6124AW/DB25 CONNECTORDDN6367AW/DB9 CONNECTOR RVN41751-CD Rib to MIC connector 1-3.5MCS2000 RKN4062BRVN41131-3.5MCS2000RVN4011 3.5MCX1000YES3000056M01RVN4063 3.5MCX1000 MARINE YES3000056M01RVN4117 3.5MDC/RDLAP DEVICESRVN4105 3.5MOBILE PROG. TOOLRVN4119 3.5MOBITEX DEVICESRVN4128 3.5MPT1327-1200 SERIES YES SEE MANUALRVN4025 3.5MSF5000/PURC/ANALOG YES0180355A30RVN4077 3.5MSF5000/10000FLD YES0180355A30RVN4017K 3.5MT 1000YES RTK4205CRVN4148 3.5MTR 2000YES3082056X02RVN4140 3.5MTRI 2000NORVN41761-CD MTS2000, MT2000*, MTX8000, MTX90001-3.5*programmed by DOS which is included in the RVN4176RVN4131 3.5MTVA CODE PLUG FIXRVN4142 3.5MTVA DOCTOR YES3080070N01RVN4131 3.5MTVA3.EXERVN4013 3.5MTX800 & MTX800S YES RTK4205CRVN4097 1-CD MTX8000/MTX9000,MTS2000,MT2000*,* programmed by DOS which is included in the RVN4176HVN9067CD MTX850/MTX8250MTX950,MTX925RVN4138 3.5MTX-LS YES RKN4035DRVN4035 3.5MX 1000YES RTK4203CRVN4073 3.5MX 800YES RKN4006BHVN9395 P100, P200 LB, P50+, P210, P500, PR3000RVN4134 3.5P100 (HVN9175)P200 LB (HVN9794)P50+ (HVN9395)P210 (HVN9763)P500 (HVN9941)PR3000 (HVN9586)YES RTK4205HVN9852 3.5P110YES HKN9755A/REX1143 HVN9262 3.5P200 UHF/VHF YES RTK4205RVN4129 3.5PDT220YVN4051 3.5PORTABLE REPEATER Portable rptr.P1820/P1821AXRVN4061C 3.5PP 1000/500NO3080385B23 & 5880385B30 RVN5002 3.5QUANTAR/QUANTRO NO3O80369E31RVN4135 3.5R100 (HVN9177)M100/M200/M110/M400YES0180358A52RVN4146 3.5RPM500/660RVN4002 3.5SABER YES RTK4203CRVN4131 3.5SETTLET.EXEHVN9007 3.5SM50 & SM120YESRVN4039 3.5SMART STATUS YES FKN5825AHVN9054 3.5SOFTWARE R03.2 P1225YES3080070N01HVN9001 3.5SOFTWARE R05.00.00 1225LS YES HLN9359AHVN9012 3.5SP50RVN4001N 3.5SPECTRA YES3080369B73 (STANDARD)0180300B10 (HIGH POWER) RVN4099 3.5SPECTRA RAILROAD YES3080369B73RVN4110 3.5STATION ACCESS MODULE NO3080369E31RVN4089A 3.5STX TRANSIT YES0180357A54RVN4051 3.5SYSTEMS SABER YES RTK4203BRVN4075 3.5T5600/T5620 SERIES NO3080385B23HVN9060CD TC3000, TS3000, TR3000RVN4123 3.5VISAR PRIVACY PLUS YES3080371E46FVN4333 3.5VRM 100 TOOLBOX FKN4486A CABLE &ADAPTORRVN4133 3.5VRM 500/600/650/850NORVN4181CD XTS 2500/5000 PORTABLES RKN4105A/RKN4106A RVN41002- 3.5XTS3000 ASTRO PORTABLE/MOBILERVN4170 3.5XTS3500YES RKN4035DRIB SET UPRLN4008E RADIO INTERFACE BOX (RIB)0180357A57RIB AC POWER PACK 120V0180358A56RIB AC POWER PACK 220V3080369B71IBM TO RIB CABLE (25 PIN) (USE WITH XT & PS2)3080369B72IBM TO RIB CABLE (9 PIN)RLN443825 PIN (F) TO 9 PIN (M) ADAPTOR (USE W/3080369B72 FOR AT APPLICATION) 5880385B308 PIN MODULAR TO 25 PIN ”D” ADAPTOR (FOR T5600 ONLY)0180359A29DUPLEX ADAPTOR (MOSTAR/TRAXAR TRNK’D ONLY)Item Disk Radio RIB Cable Number Size Product Required Number Item Disk Radio RIB Cable Number Size Product Required NumberUtilizing your personal computer, Radio Service Software (RSS)/Customer Programming Software (CPS)/CustomerConfiguration Software (CCS) enables you to add or reprogram features/parameters as your requirements change. RSS/CPS/CCS is compatible with IBM XT, AT, PS/2 models 30, 50, 60 and 80.Requires 640K RAM. DOS 3.1 or later. Consult the RSS users guide for the computer configuration and DOS requirements. (ForHT1000, MT/MTS2000, MTX838/8000/9000, Visar and some newer products —IBM model 386, 4 MEG RAM and DOS 5.0 or higher are recommended.) A Radio Interface Box (RIB) may be required as well as the appropriate cables. The RIB and cables must be ordered separately.Licensing:A license is required before a software (RVN) order is placed. The software license is site specific (customer number and ultimate destination tag). All sites/locations must purchase their own software.Be sure to place subsequent orders using the original customer number and ship-to-tag or other licensed sites; ordering software without a licensed customer number and ultimate tag may result in unnecessary delays. To obtain a no charge license agreement kit, order RPX4719. To place an order in the U.S. call 1-800-422-4210. Outside the U.S., FAX 847-576-3023.Subscription Program:The purchase of Radio ServiceSoftware/Customer Programming/Customer ConfigurationSoftware (RVN & HVN kits) entitles the buyer/subscriber to three years of free upgrades. At the end of these three years, the sub-scriber must purchase the same Radio Service Software kit to receive an additional three years of free upgrades. If the sub-scriber does not elect to purchase the same Radio Service Software kit, no upgrades will be sent. Annually a subscription status report is mailed to inform subscribers of the RSS/CPS/CCS items on our database and their expiration dates.Notes:1)A subscription service is offered on “RVN”-Radio Service Software/Customer Programming/Customer Configuration Software kits only.2)“RVN” software must only be procured through Radio Products and Services Division (RPSD). Software not procured through the RPSD will not be recorded on the subscription database; upgrades will not be mailed.3)Upgrades are mailed to the original buyer (customer number & ultimate tag).4)SP software is available through the radio product groups.The Motorola General Radio Service Software Agreement is now available on Motorola Online. If you need assistance please feel free to submit a “Contact Us” or call 800-422-4210.SMART RIB SET UPRLN1015D SMART RIB0180302E27 AC POWER PACK 120V 2580373E86 AC POWER PACK 220V3080390B49SMARTRIB CABLE (9 PIN (F) TO 9 PIN (M) (USE WITH AT)3080390B48SMARTRIB CABLE (25 PIN (F) TO 9 PIN (M) (USE WITH XT)RLN4488ASMART RIB BATTERY PACKWIRELESS DATA GROUP PRODUTS SOFTWARERVN4126 3.59100-386/9100T DEVICES MDVN4965 3.59100-WS/T CONFIG’TN RVN41173.5MDC/RDLAP DEVICESPAGING PRODUCTS MANUALS6881011B54 3.5ADVISOR6881029B90 3.5ADVISOR ELITE 6881023B20 3.5ADVISOR GOLD 6881020B35 3.5ADVISOR PRO FLX 6881032B30 3.5BR8506881032B30 3.5LS3506881032B30 3.5LS5506881032B30 3.5LS7506881033B10 3.5LS9506881035B20 3.5MINITOR III8262947A15 3.5PAGEWRITER 20008262947A15 3.5PAGEWRITER 2000X 6881028B10 3.5TALKABOUT T3406881029B35 3.5TIMEPORT P7308262947A15 3.5TIMEPORT P930NLN3548BUNIVERSAL INTERFACE KITItem Disk Radio NumberSize Product。
5EUROTEC GROUP SERVICE - Spare parts distribution11004066REB004066COVER - 50/50312417041REB417041NUT, DOOR BUFFER13307003REB307003NUT-LEDGE, FOR ROD14304021REB304021ROD, DOOR GUIDE 50/500/453/463/50315325036REB325036PIN, DOOR HINGE 5016311019REB311019HINGE, DOOR 45/46/50..17325066REB325066LOCK PIN BETA 246/25018999108REB999108GRUPPO CALAMITA PORTA 453/463/500/50319022095REB022095PANEL, REAR CPL 50/503110480058REB480058CAP, RUBBER D.17111437081REB437081GASKET, DOOR - 50/503112033301REB033301BRACKET, FIXED FOR DOOR GASKET 50/503113994012DWS30GRUPPO SERRATURA EB/F 22/44114029590DOOR115015064RACK SLIDE SX.116015063RACK SLIDE DX.117480057REB480057CAP, RUBBER D.14118408006REB408006STUD, FOR TANK FILTER - GREY119459004REB459004PIPEHOLDER, RUBBER DI.34120459006REB459006FAIRLEAD, Di9/De16 22121030080REB030080PROTECTION, LOW. SOCLE 50/503122461019REB461019FOOT, ADJUST. D30 M8123012326FRONT PANEL125025444CONTROL PANEL21214104PLASTIC PROTECTION22211013FLAT WIRE23417119NUT, M3 PLASTIC WHITE24419036SPACER, M325227084PUSH BUTTONS ASSEMBLY26026073POLYESTERE27224003REB224003PRESSURE SWITCH - 55/3528224010PRESSURE SWITCH, DRAIN PUMP SAFETY 110/75 29035031REB035031UNION, Y-TYPE, PRESSURE SWITCH 760210423011REB423011CLAMP, SPRING-TYPE211143013REB143013PIPE, PVC GREEN 4X7212220011REB220011* TERMINAL BOARD, 5-POLES + EARTH FV.122213459005REB459005CABLE CLAMPS, STEAB art.5024214H.374339-2CABLE H07RN-F 5X2.5X3.0MT21580871MAGNETIC DOOR SWITCH216230086REB230086RESISTANCE, TANK 2700W/220V-3200W/240V 22/44/50 217456015REB456015O-ring 112 9.92X2.62218463007REB463007LUG, RESISTANCE PROTECTION219999160GRUPPO BULBO SONDA VASCA220231016TEMP. PROBE221230111RESIST.B.4900W/230-400V222456002REB456002O-ring 48x6,222369870BOILER HEATING ELEMENT PROTECTION22469871PROBE HOLDER225228010FUSE226999298SCHEDA GET50(2 DISPLAY)235229040RELAY 62.83.8.230.0300237214090EL.PROTECTION,TRANSP.453238228004FUSE, 5X20 4A FAST239210010FUSE-HODER240210011PLATE241209021PERISTALTIC DISPENSER (NBR-3)242468151DZR150NT UNION, EXTRA DET. CPL NM * WELDED243143194REB143194PIPE 4x6 CRISTAL, TRANSP.244143219REB143219TUBE, SANTOPRENE 6X10 FITTINGS+METAL RINGS 245121075REB121075FILTER, SUCT.INOX (775239-001)251236047REB236047THERM.,CONT. /S.95ø+/-3ø31441009REB441009INSERT, SEAL D10 COLL.S621-32437014REB437014GASKET, LOWER MANIFOLD S85033143174REB143174PIPE, WATER LOW.COLL. RINSE 5034111030NEUTRAL LOWER MANIFOLD ASS. E50NM+PLUG 35035064BRACKET, DRAIN PUMP FOR MANIFOLD 50NM36127026REB127026SLEEVE, PUMP DELIVERY 22/50037143240PIPE, H-)COND.UPPER38437041REB437041GASKET 3/4 GAS LOAD39929169RAT32TUBO DI CARICO DEL TERMOPLASTICO310240011REB240011LOADING S.VALVE 1-WAY311104060BOILER312143005SPG10PIPE, PRESSURE SWITCH TP 5x11 (CASER/15/NL C4N) 313209025RINSE AID DISPENSING PUMP314121017FILTER, RINSE-AID SUCT.315H.775601PIPE 4x6 CRISTAL BLUE PVC316142053REB142053OVERFLOW, DRAIN 50/503 NM317121078REB121078FILTER, DRAIN PUMP 463/503318303019REB303019RING, ELASTIC FOR DRAIN PUMP FILTER 503 319136023REB136023DRAIN, BENT 50/503320437063CGG42GASKET, DRAIN 50321417081CDP2NUT, PLASTIC 1'- 1/4322127050REB127050SLEEVE, RIGIDO ASP.P.S. 500/503323127044REB127044SLEEVE, SUCT.DRAIN PUMP 353/403324468152REB468152UNION, DRAIN CLEAN.3325127037REB127037SLEEVE, DRAIN CLEAN.3326144003REB144003RELIEF VALVE, DRAIN PUMP327423024REB423024CLAMP, PLAST.FOR DRAIN PUMP PIPE CLAMP. 328143178REB143178PIPE, DRAIN - 50329130105REB130105DRAIN PUMP (50/503/460/BD18)330130150DRAIN PUMP (50/503/460/BD18) 60HZ331143189REB143189TUBE, DRAIN SFIATO DVGW CLEAN.3332144011REB144011CHECK VALVE (EB)333143004REB143004PIPE, PRESSURE SWITCH TP 10X17 (CASER/15NL C4N) 41984005REB984005GRUPPO CAMPANA PRESSOST.35/4042423011REB423011CLAMP, SPRING-TYPE43468029REB468029UNION, PRESSURE SWITCH BELL44456020REB456020O-ring 3050 R49545437019REB437019GASKET, CAMP. PRESS. V.M.46107005REB107005PRESSURE SWITCH BELL EB 35/4047142052REB142052OVERFLOW 50/503 NM48136023REB136023DRAIN, BENT 50/50349437063CGG42GASKET, DRAIN 50410417081CDP2NUT, PLASTIC 1'- 1/4413478059SUPPORT, FILTER GREY+EXTENSION414437015REB437015GASKET, PUMP FILTER S651-415127041REB127041SLEEVE, SUCTION 463/503416929169RAT32TUBO DI CARICO DEL TERMOPLASTICO417437041REB437041GASKET 3/4 GAS LOAD418240016DEV3S16LOADING S.VALVE 1-WAY 3/4 230V PART.16L 419143246PIPE, -)SOFTENER421999288GRUPPO VALVOLA DEVIATR.CON RIDUTTORE 422143265NOT IN PRICE-LIST423143004REB143004PIPE, PRESSURE SWITCH TP 10X17 (CASER/15NL C4N) 424117007WATER SOFTNER425406998REB406998SALT CONTAINER NM426480005REB480005SALT CONTAINER SCREW CAP427456052REB456052O-ring 144428429011REB429011RING NUT, SALT CONT.429437034REB437034GASKET, D68D81S3 RUBBER51303029REB303029RING, DRIPPING 46/50..52437064REB437064GASKET, MANIFOLD, CENTR.UPP.5053143240PIPE, H-)COND.UPPER54115113PIPE, WASHINGEST.PL.+ SLEV.+115111 SP405 55127036REB127036SLEEVE, LOW.WASH.COND. 50/f56121139FILTER57121138FITER58408006REB408006STUD, FOR TANK FILTER - GREY61327006REB327006PIN, LOW.WASH/RINSE 21/45362990108GRUPPO LAV.RISC.SUPER.50/UNIVERSALE63106007RINSE ARM, RH S651-85064106006REB106006WASH.ARM,LH+ SCREW S651-850-50365106005RINSE ARM, LH S651-85066140007REB140007SPRAY S621-3-31-67429006REB429006RING NUT, RINSE S621-3-31-368429007REB429007RING NUT, WASHING S621-3-31-369140008REB140008SPRAY S621-3-31-610106008REB106008WASH.ARM, RH+ SCREW S651-850-503611447128REB447128KNOB, FIX, WASH. GREY612454002REB454002PAWL 21/31613437100PACKING614129039REB129039WASH-RINSE-ARM ASSB., LOWER 353/403RAL7012 61580959RINSE ASSEMBLY616926132CAP, PLASTIC FOR WASH. ARM (DWT312)61780623RING 22X9,5X161880697NUT61969632ARM BODY620456072O-RING 6X2621140025SPRAY D.2,562280345NEW WASH BOSS ASSEMBLY623303032RING, INOX WASH. SEAL X5624417111BUSHING, WASH-ARM X5625308031RING NUT, WASH.BUSH X5626325094WASH COMB PIN SHAFT627199058DISC, WATER FLOW REDUCER PLAST.E55628115075REB115075CENTR.PIPELINE - LOWER 50 (H=108)629437014REB437014GASKET, LOWER MANIFOLD S850633456060O-ring 2025(CGR2025)634456019REB456019O-ring 203763580700PERNO RISCIACQUO D14 M10X171130109REB130109PUMP HP 0.80 220/240-50 - 50/50072130119PUMP B237 HP 0.80 220/60 5073314001REB314001BEARING 6201/2Z74206003CONDENSER - 12.5 mF76315017REB315017FLANGE, W/COVERING DUCT B23777437049REB437049GASKET, PUMP 227778141002REB141002SEAL, MECH., REVOLVING D 1279124065WASH PUMP IMPELLER FOR B237 FOR DISH- WASHER 711116021REB116021PUMP SHELL, B237712315022REB315022FLANGE, PUMP LGB T-173/174713456031REB456031O-ring T30-1297 D.2714141007REB141007SEAL, MECH..D.26x13x5,5 BR.715124031RAG291IMPELLER, CLOSED 50HZ D.104 T170716124053IMPELLER, CLOSED 60HZ T173-175717116019REB116019PUMP SHELL, 50 T-173。
This guide describes the minimum steps you must perform to get Oracle’s Sun SPARC Enterprise T5140server to power on and boot for the first time using the preinstalled Solaris Operating System (Solaris OS).Servers that use DC input power require you to build and connect the power cords to specific safety specifications.The specifications are described in the Sun SPARC Enterprise T5140and T5240Servers Installation Guide that is available from /app/docs/prod/sparc.t5140.FIGURE 1Sun SPARC Enterprise T5140ServerShipping ContentsQuick Setup InstructionsFor quick installation and configuration,follow these steps.For more detailed information,refer to the complete online product documentation set at:/app/docs/prod/sparc.t5140Understand the following information before you set up the server for the first time:■Choose the best instructions for your situation –These quick setup instructions work for any networkingenvironment,and require the use of a terminal device for connectivity to a serial port.If you have a networking environment running DHCP,you can configure your system using the Ethernet management port.To take advantage of DHCP setup method,refer to the online installation guide instead of these instructions.■Set aside sufficient time –Installation times vary,but if you are performing these setup instructions for the first time,plan to spend about 45to 75minutes to complete all of these instructions.Additional time might be required for installing optional hardware and rackmounting kits.■Gather your configuration information –During the configuration,you are prompted for time zone and networking parameters that are specific to your environment.For a list of information you need,see Step 9.■Obtain a terminal device –You configure this rackmountable server through the service processor (SP)using the built-in serial and network management ports,and not through a graphical interface and Sun keyboard.For more information about the terminal device,see Step 3.■Do not apply power at this time –This system includes a service processor (SP)that is used to configure and boot the main host server.To properly configure the host server and view SP messages,do not apply power to the server until the SP and host networking connections are made,as described in this guide.Quantity Item1Server 2RJ-45Ethernet cable 1RJ-45to DB-25adapter (crossover)1RJ-45to DB-9adapter (crossover)2DC powerconnectorsSun SPARC Enterprise T5140 ServerGetting Started Guide (For Models That Run on DC Input Power)1.Unpack the server,and check that you received all of the shipping contents.2.Place the server in its intended location for verification.For rackmounting instructions,refer to the instructions included with the rail kit,the service label on the server,and to the online Sun SPARC Enterprise T5140and T5240Servers Installation Guide.3.Connect a serial cable between the server’s SER MGT port(FIGURE2)and a terminal device.This connection provides your initial communication with the service processor(SP).The terminal device can be a terminal,a terminal server,or a laptop with terminal emulation software running.The device must be set up to communicate using9600baud,8bit,no parity,1stop bit.A null modem configuration is needed,meaning the transmit and receive signals are reversed(crossed over)for DTE to DTE communications.You can use the supplied RJ-45crossover adapters with a standard RJ-45cable to achieve the null modem configuration.FIGURE2Server Connections4.(Optional)Connect an Ethernet cable between the server’s Net MGT port(FIGURE2)and the network to whichfuture connections to the SP and host will be made.After the initial configuration of the system using the SP SER MGT port,communication with the SP and host is usually performed through this Ethernet interface.5.Connect an Ethernet cable between one of the server’s NET ports(FIGURE2)and the network to which the serverwill communicate.6.Build and connect your DC power cables into the server power supplies and into separate power sources.Instructions for building the DC power cables are in the SPARC Enterprise T5140and T5240Servers Installation Guide.Note-Only one power connection is required for e two power connections for redundancy.When power is applied,the SP initializes and power supply LEDs illuminate.After a few minutes,the SP login prompt appears on the terminal device.The host is not initialized or powered on yet.7.At the terminal device,log in to the SP as root with a password of changeme.SUNSP00144FAC732F login:rootPassword:changeme. . .->After a brief delay,the SP prompt is displayed(->).At this point,there are many commands you can perform using the Integrated Lights Out Manager interface.Additional SP information,such as how to change the password and how to set up the SP network parameters is available in the online documentation set.8.Power on the server and redirect the host output to display on the serial terminal device:->start /SYSAre you sure you want to start /SYS (y/n)?y->start /SP/consoleAre you sure you want to start /SP/CONSOLE (y/n)?ySerial console started. To stop, type #.. . .After you start the SP console,the server initialization takes approximately20minutes to complete.9.When prompted,follow the onscreen instructions and enter the following configuration information.You will be prompted to confirm the configuration several times,enabling confirmation and changes.If you are not sure how to respond to a particular value,you can accept the default,and make future changes when the Solaris OS is running.Parameter DescriptionLanguage Select a number from the displayed language list.Locale Select a number from the displayed locale list.Terminal Type Select a terminal type that corresponds with your terminal device.Network?Select Yes.Multiple Network Interfaces Select the network interfaces that you plan to configure.If you are not sure,select the firstone in the list.DHCP?Select Yes or No according to your network environment.Host Name Enter the host name for the server.IP Address Enter the IP address for this Ethernet interface.Subnet?Select Yes or No according to your network environment.Subnet Netmask(If subnet was Yes)Enter the netmask for the subnet for your network environment.IPv6?Specify whether or not to use IPv6.If you are not sure,select No to configure the Ethernetinterface for IPv4.Security Policy Select either standard UNIX security(No)or Kerberos Security(Yes).If you are not sure,select No.Confirm Review the onscreen information and change it if needed.Otherwise,continue.Name Service Select the name service according to your network environment.Note–If you select a name service other than None,you will be prompted for additional nameservice configuration information.NFSv4Domain Name Select the type of domain name configuration according to your environment.If you are notsure,select Use the NFSv4domain derived by the system.Time Zone(Continent)Select your continent.Time Zone(Country or Region)Select your country or region.Time Zone Select the time zone.Date and Time Accept the default date and time or change the values.root Password Enter the root password twice.This password is for the superuser account for the Solaris OSon this server.This password is not the SP password.When the configuration menus are completed,the server reboots and displays the Solaris login prompt.10.Log in to the server and explore the capabilities.There are many commands you can use to verify the functionality of the system.The following list describes a few of them:■showrev–Displays the hostname and system architecture e the-a option with this command to see the patches that are installed.■psrinfo–Displays information about the number and status of the processors and cores in the host.Review the Solaris OS man pages and documentation for more details.Accessing Additional InformationYou can view,print,and download additional information for this product from the following URLs:■Sun’s Sun SPARC Enterprise T5140server documentation set,including important documents such as product notes: /app/docs/prod/sparc.t5140■A broad selection of Sun documentation,including localized versions:/documentation■Preinstalled Solaris™OS information:/software/preinstall■CoolThreads™–Overview access to Cool Tools:/servers/coolthreads/tnb/index.jsp■CoolThreads–CMT Tuning and Resources:/servers/coolthreads/tnb/t2.jspTechnical SupportIf you have technical questions about this product that are not answered in this document,go to:/service/contactingDocumentation FeedbackSubmit comments about this document by clicking the Feedback[+]link at:/Please include the title and part number of your document with your feedback:Sun SPARC Enterprise T5140Server Getting Started Guide(DC Models),part number820-5840-11Copyright©2008,2010,Oracle and/or its affiliates.All rights reserved.FUJITSU LIMITED provided technical input and review on portions of this material.Copyright©2008,2010,Oracle et/ou ses affiliés.Tous droits réservés.Entrée et revue tecnical fournies par FUJITSU LIMITED sur des parties de ce matériel.Part No. 820-5840-11, Rev. AJuly 2010。
SDS No.- T-36-04 (Revision–M)Lithium Battery Information Sheet1.Section 1: IdentificationProducts Name: Primary (non-rechargeable) Lithium metal Thionyl Chloride (Li/SOCl2) cells and batteries. Cells include the models of TL, TLH, and TLL, 3.6V series. This Battery Information Sheet covers the the above models: 2100, 2134, 2135, 2137, 2150, 2155, 2186, 2200, 2300, 2450, 4902, 4903, 4920, 4930, 4934, 4935, 4937, 4940, 4951, 4955, 4986, 5101, 5104, 5113, 5114, 5134, 5135, 5137, 5151, 5155, 5186, 5233, 5242, 5276, 5293, 5315, 5902, 5903, 5920, 5930, 5934, 5935, 5937, 5940, 5955, 5323, 7902, 7955, 7903, 7920, 7930, 7937, 8902, 8955, 8903, 8920, 8930, and 8937 with all their finishing versions and batteries assembled from them, denoted by “/” followed by letters or digits.Manufacturer Name: Tadiran Batteries Ltd., P. O. Box 1, Kiryat Ekron, Israel 70500.US office address: 2001 Marcus Avenue, Suite 125E, Lake Success, NY 11040 Emergency Telephone No: CHEMTREC: 1-800-424-9300Tel. for information: 1-516-621-4980Tel. for information 972-8-944-45032.The Lithium Thionyl chloride batteries described in this Battery Information Sheet are hermetically sealed units, which are not hazardous when used according to the recommendations of the manufacturer.Under normal condition of use of the batteries, the electrode materials and the liquid electrolyte they contained are non-reactive provided the battery integrity is maintained. Risk of exposure exists only in case of mechanical, electrical or thermal abuse. Thus the batteries should not short circuit, recharge, puncture, incinerate, crush, immerse in water, force discharge, or expose to temperatures above the temperature range of the cell or battery. In these cases there is risk of fire or explosion.Protection from charging:Whenever lithium batteries are not the single power source in a circuit, Whenever lithium batteries are not the single power source in a circuit, the measures recommended by Underwriters Laboratories are relevant. The relevant protection means should be recommended/approved by TADIRAN.* TLV- Threshold Limit Value is personal exposure limits determined by ACGIH (American Council of Governmental Industrial Hygienists).IMPORTANT NOTE: The above levels are not anticipated under normal use conditions.4.Section 4: First aid measuresIn case of battery rupture, explosion, or major leakage, evacuate personnel from contaminated area and provide good ventilation to clear out corrosive fumes, gases or the pungent odor. Seek immediate medical attention.Eyes - First rinse with plenty of water for 15 minutes (remove contact lenses if easily possible), and then seek medical attention.Skin - Remove contaminated clothes and rinse skin with plenty of water or shower for 15 min. Refer to medical attention.Inhalation - Remove to fresh air, rest, and half-upright position, use artificial respiration if needed, and refer to medical attention.Ingestion - rinse mouth, DO NOT induce vomiting, give plenty of water to drink, and refer to medical attention.5.Section 5: Fire - fighting measuresFLASH POINT: NA LOWER (LEL): NA FLAMMABLE LIMIT IN AIR: NA UPPER (LEL): NA EXTINGUISHING MEDIA:1. Lith- X (Class D extinguishing media) is the only effective on fires involving a few lithium batteries. If the cells are directly involved in a fire DO NOT USE: WATER, SAND, CO2, HALON, and DRY POWDER OR SODA ASH EXTINGUISHERS.2. If the fire is in adjacent area and the cells that are either packed in their original containers or unpacked, the fire can be fought based on fueling material, e.g., paper and plastic products. In these cases the use of copious amounts of cold water is effective extinguishing media. Storage area may also employ sprinkler system with cold water.AUTO-IGNITION: NASPECIAL FIRE FIGHTING PROCEDURES: Wear self-contained breathing apparatus to avoid breathing of irritant fumes (NIOSH approved SCBA & full protective equipment). Wear protective clothing and equipment to prevent body contact with electrolyte solution.Fire may be fought, but only from safe fire-fighting distance. Evacuate all persons from immediate area of fire.UNUSUAL EXPLOSION AND FIRE EXPLOSION: Battery may explode when subject to: excessive heat (above 150⁰C), recharged, over-discharged (discharge below 0V), punctured and crushed. During thermal decomposition generation of chlorine (Cl2), hydrogen chloride (HCl), and sulfur dioxide (SO2) can be formed.6.PROCEDURES TO CONTAIN AND CLEAN UP LEAKS OR SPILLS: The material contained within the battery would only be released under abusive conditions.In the event of battery rapture and leakage: contain the spill while wearing proper protective clothing and ventilate the area. Then, cover with sodium carbonate (Na2CO3) or 1:1 mixture of soda ash and slaked lime. Keep away from water, rain, and snow. Placed in approved container (after cooling if necessary) and disposed according to the local regulations. NEUTRALIZING AGENTS: Sodium carbonate (Na2CO3) or 1:1 mixture of soda ash and slaked lime. WASTE DISPOSAL METHOD: Product decomposed by water must be neutralized. if sufficiently diluted, it may be added to waste water if it is sufficiently diluted.PRECAUTIONS IN HANDLING AND STORAGE: avoid short-circuiting, over-charging and heating to high temperatures. Store the batteries in dry and cool area and keep container dry and tightly closed in well-ventilated area. Store cells away from food and drink.OTHER PRECAUTIONS; Never attempt to disassemble, machine, or otherwise modify batteries or injury may result.7.The batteries should not be opened, destroyed or incinerate, since they may leak or rupture and release to the environment the ingredients that they normally contained in the hermetically sealed container.HANDLING- Do not short circuit terminals, or expose to temperatures above the temperature rating of the battery, over charge the battery, forced over-discharge (voltage below 0.0V), throw to fire.Do not crush or puncture the battery, or immerse in liquids.STORAGE- is preferably done in cool (below 30⁰C), dry and ventilated area, which is subject to little temperature change.Do not place the battery near heating equipment, nor expose to direct sunlight for long periods. Elevated temperatures can result in shortened battery life and degrade performance.Keep batteries in original packaging until use and do not jumble them.Do not store batteries in high humidity environment for long periods.OTHER- cells and batteries are not rechargeable batteries and should not be charged. Applying pressure and deforming the battery may lead to disassembly followed by eye skin and throat irritation.Follow manufacturer recommendations regarding maximum recommended current and operating temperature range.GENERAL- The following safety measures are not necessary in normal use. They need only be applied if there is a risk that, in use or handling, the recommendations, as outlined in Section 3, have not been followed.RESPIRATORY PROTECTION: In case of abuse or leak of liquid or fumes, use NIOSH approved Acid Gas Filter Mask or Self-Contained Breathing Apparatus.VENTILATION: In case of abuse, use adequate mechanical ventilation (local exhaust) for battery that vents gas or fumes.PROTECTIVE GLOVES: In case of spill use PVC or Nitrile gloves of 15 mils (0.015 inch) or thicker. EYE PROTECTION: Use ANSI approved chemical worker safety goggles or face shield.OTHER PROTECTIVE EQUIPMENT: In case needed, chemical resistance clothing is recommended along with eye wash station and safety shower should be available meeting ANSI design criteria. WORK HYGIENIC PRACTICES: Use good hygiene practice. Wash hands after use and before drinking, eating or smoking. Launder contaminated cloth before reuse. SUPPLEMENTARY SAFETY AND HEALTH DATA: If the battery is broken or leaked the main hazard is the electrolyte. The electrolyte is mainly solution of Lithium chloride (LiCl), and aluminum chloride (AlCl3) in Thionyl chloride (SOCl2).Fires may be fought but only from safe fire fighting distance, evacuate all persons from immediate area of fire. Prevent heating of the battery, charging the battery, discharge to predetermined limit, do not crush, disassemble, incinerate or short circuit.9.Section 9: Physical and chemical propertiesBoiling point (760 mm Hg) NA, unless individual components exposed Vapor Pressure (mm Hg, 25ºC) NA, unless individual components exposed Vapor Density (air=1) NA, unless individual components exposed Density (gr/cc) > 1 gr/ccVolatile by Volume (%) NAEvaporation Rate (butyl acetate=1) NA, unless individual components exposed Physical State SolidSolubility in Water (% by weight) NA, unless individual components exposed PH NA, unless individual components exposed Appearance Geometric Solid ObjectOdor If leaking, gives off pungent corrosive odor10.Section 10: Stability and reactivitySTABLE OR NOT STABLE StableINCOMPATIBILITY (MATERIAL TO AVOID) Strong mineral acids, water and alkali solutions.HAZARDOUS DECOMPOSITION PRODUCTS 1. Reaction of lithium with water: Hydrogen (H2), Lithium hydroxide (LiOH).2. Thermal decomposition over 150⁰C: Sulfur oxides, (SO2, SO3), Sulfur chlorides (SCl2, S2Cl2), Chlorine (Cl2), Lithium oxide, Li2O3. Electrolyte with water: Hydrogen Chloride (HCl) and SO2DECOMPOSITION TEMPERATURE (⁰F) NAHAZARDOUS POLYMERIZATION: May Occur____ Will Not Occur __X__ CONDITIONS TO AVOID Avoid mechanical abuse and electrical abuse such as short-circuiting, overcharge, over-discharge, (voltage reversal)and heating.THRESHOLD LIMIT VALUE (TLV) AND SOURCE: NAHEALTH HAZARD ACUTE AND CHRONIC: Inhalation, skin contact, eye contact and ingestion are not likely by exposure to sealed battery.Inhalation, skin contact and eye contact are possible when the battery is opened. Exposure to internal contents, the corrosive fumes will be very irritating to skin, eyes and mucous membranes. Overexposure can cause symptoms of non-fibrotic lung injury and membrane irritation.Carcinogenicity- NTP: NoCarcinogenicity- IARC: NoCarcinogenicity- OSHA: NoExplanation of Carcinogenicity- No ingredient of a concentration of 0.1% or greater is listed as a carcinogen or suspected carcinogen.SIGNS AND SYMPTOMS OF OVEREXPOSURE: Exposure to leaking electrolyte from ruptured or leaking battery can cause:For further information refer to section 4.12.Section 12: Ecological information1.When properly used or disposed the battery does not present environmental hazard.2.Cells do not contain mercury, cadmium, lead or other heavy metals.3.Do not let internal components enter marine environment. Avoid release to waterways,wastewater or ground water.13.Section 13: Disposal Considerations4.Dispose in accordance with the applicable regulations in country and state.5.Disposal should be performed by permitted, professional disposal firms knowledgeable inFederal, State or Local requirements of hazardous waste treatment and hazardous waste transportation.6.Incineration should never be performed by battery users, but eventually by trainedprofessional in authorized facility with proper gas and fume treatment.7.Battery recycling should be done in authorized facility.14.Section 14: Transport informationShipping name:UN 3090: Lithium Metal Cells and BatteriesUN 3091: Lithium Metal Cells and Batteries contained in equipment, orLithium Metal Cells and Batteries packed with equipmentShipping information: the cells and batteries have passed successfully the tests defined in “UN Manual of Tests and Criteria”, Section 38.3 (the UN tests). The cells and batteries must be packed in accordance with Packing Instructions / Special Provisions (SP) of the applicable code, e.g., IATA (57th revised edition)/ICAO (Packing Instructions: PI968, PI969 and PI970), IMDG Code (SP188) and ADR (SP188). When required, reference shall be made to UN number 3090 (lithium ion batteries) or UN 3091 when packed with or contained in equipment.Transportation within, to and from the US: are governed by the US DOT CFR 49, Parts 171, 172, 173 and 175. They details the required packaging and labels and transportation mode of cells transported separately or in equipment. The battery cannot be shipped, within, to, and from the US by passenger aircraft. Air shipments of cells can be done only by cargo aircraft.Hazard Classification: Class 9Packing Group: N/ABattery label: Identification and labeling should be in compliance with the applicable regulations. In addition, it should also include cell/battery title, nominal voltage, lot number and warning.15.1.All the cells and batteries are defined as “articles” and thus are exempt from therequirements of the Hazard Communication Standard”.2.The internal component (Thionyl chloride) is hazardous under the criteria of the FederalOHSA Hazard Communication Standard 29 CFR 1920.1200.3.NFPA rating- Lithium batteries are not included in the NFPA material list. Below is the NFPArating for lithium metal. Lithium metal is an internal component, enclosed by hermetically sealed metallic can. Under normal application is not exposed.16.Section 16: Other informationThe information and the recommendations set forth are made in good faith and believed to be accurate at the date of preparation. The present file refers to normal use of the product in question. Tadiran Batteries makes no warranty expressed or implied.Assembly of battery packs:The design and assembly of battery packs require special skills, expertise and experience. Therefore it is not recommended that the end user will attempt to self-assemble battey packs. It is preferable that any battery using lithium cells will be assembled by TADIRAN to ensure proper battery design and construction. A full assembly service is available from TADIRAN who can be contact for further information. If for any reason, this is not possible, TADIRAN can review the pack design in confidential to ensure that the design is safe and capable of meeting the stated performance requirements.。