血液净化费森尤斯共37页
- 格式:ppt
- 大小:4.64 MB
- 文档页数:37
费森尤斯维修手册(总37页) -CAL-FENGHAI.-(YICAI)-Company One1-CAL-本页仅作为文档封面,使用请直接删除W o名词缩写解释HF Hemofiltration 血液滤过HDF Hemodiafiltration 血液滤透4008选件BPM血压监测器BTM血温监测器BVM血容量监测器OCM在线清除率监测SN-Double Pump单针泵DIASAFE plus Filter细菌过滤器ONLINE plus在线血滤系统Bibag(Standard)干粉CDS中央供液系统模组空间Blood Pump血泵Heparin Pump肝素泵Level Detector空气监测器Bibag/Conc.干粉附注错误说明指定的数值是程序中使用的精确数值具体数值和公差如下:1. Arterial pressure 动脉 3 mmHg/digit 和测定值的± 1位压2. Venous pressure 动脉压 3 mmHg/digit 和测定值的± 1位3. Dialysate Pressure 透析液压粗略 6.0 mmHg/digit和测定值的± 1位优良0.5 mmHg/digit和测定值的± 1位4. CD resolution0.06 mS/digit和精确值的± 1位5. Temperature 温度0.05 °C/digit和精确值的± 1位开始和运行测试的先决条件错误信息描述Power failure测试进行中的电源失败.Dialines not conn透析液管路没有插入到冲洗桥中. Shunt Cover open冲洗桥打开状态.Connect Conc.Line Wrong conc. Supply A液连接器在冲洗腔中或者完全没有连接. 该错误信息取决于中央供液系统预选中的设置菜单.Blood Sensed by OD光学探测器检测到系统中有血液.Flow alarm进或出透析器的线路打结, 故障发生在水路中. Water alarm供水中断.单独测试步骤的描述Bypass test (旁路测试).................................................................. ...... ........................................ . (6)Optical detector test (光学探测器测试).................................................................. .............. (8)Blood system test (血系统测试).................................................................. ............................ . (10)Venous pressure system test (静脉压系统测试)................................................................. . (13)Air detector test (空气探测器测试).................................................................. (15)Display test (显示测试).................................................................. . (18)Arterial pressure system test (动脉压系统测试).................................................................. (20)Battery test (蓄电池测试).................................................................. (21)Blood leak test (漏血测试).................................................................. (23)Temperature test (温度测试).................................................................. .................................. . (25)Negative pressure holding test (负压保持测试).................................................................. (27)Positive pressure holding test (正压保持测试).................................................................. .. (29)UF function test (超滤功能测试).................................................................. .. (34)Conductivity test (电导率测试).................................................................. . (37)Diasafe/HDF filter test (细菌过滤器/血液滤透过滤器测试) (39)Bypass test 旁路测试检查下面的功能:–加热器继电器。