必威尔步进式开水器ES-B30
- 格式:doc
- 大小:126.50 KB
- 文档页数:1
目录1整机概述 (3)1.1电热水器定义 (3)1.2电热水器分类 (3)1.3产品特色 (3)1.4规格与技术参数 (2)2部件名称 (3)3拆装程序 (8)4操作方法、电控功能 (13)4.1按键及功能概要表 (13)4.2电热水器基本组成 (13)4.3电热水器显示内容及主要功能模式 (13)4.3.1LED显示内容及系统配置功能主要包括 (13)4.3.2机身面板显示内容 (14)4.4基本参数及要求 (14)4.5、按键及显示屏具体功能要求 (15)4.6功能的详细说明 (16)4.7空壳机内容显示 (21)4.8内胆容量设置功能 (21)4.9、报警功能与故障自检(空壳机无此功能) (21)4.10、其他技术要求 (22)5故障代码表 (23)6零部件清单 (23)详细介绍1、全新异型造型;2、机身分为前后壳,均为HIPS塑料;白色●向外拉取出电源板安装盖电源板显示板遥控器图1:显示面板图遥控器对应按键位置:图1:遥控器面贴图4.4基本参数及要求1.额定工作电压:AC220V/50Hz2.整机额定功率3200W“开/关”键度,加热时“太阳花”图标循环点亮,保五、故障代码八、零部件清单(附有明细)F60-32EQ3(HEY)明细:结构级别编号名称代号(图号)数量112951000000841排水阀DT_245-01A1 116151000002322内销说明书F6030-LS3Y-131 112451000000501保温棉F60-32EQY-061 112151000000610标记套D30-20R-201 112151000000622标记套D30-20R-211 112151000000646水管DT-681 112151000002901定位座F60-30EQ1Y_02-032 112151000002902定位座F60-30EQ1Y_02-0111 112151000002903定位座F60-30EQ1Y_02-022 116351000000237说明书包装袋DT-441 117451000003441电源线DT.79F1 110502006000052标签纸DT-960.00106 116351000000701胆口泡F60-30EQ1Y-191 116351000001881上包装垫F6030-ES2Y-021 1113015120000911型六角螺母GBT61705 111301801000004T型螺栓MJ05-001125 116351000000704堵泡F60-30EQ1Y-221 112951000000421出水管组件F60-30EQ1Y_38121051030Y01242F60-32EQ3(HEY) 电热21051030Y01243F80-32EQ3(HEY) 电热21051030003387F60-32EQ3(HEY)电热水21051030003386F80-32EQ3(HEY) 电热。
全国潜水泵十大品牌国内不锈钢潜水泵品牌影响力总评榜1.上海沈泉泵阀制造有限公司上海沈泉泵阀制造有限公司是一家专业生产,销售管道泵,排污泵,消防泵,化工泵等给排水设备的厂家,产品涉及工矿企业、农业、城市供水、石油化工、电站、船舶、冶金、高层建筑、消防供水、工业水处理和纯净水、食品、制药、锅炉、空调循环系统等行业领域。
2. 上海泉尔泵阀制造有限公司上海泉尔泵阀制造有限公司是一家集生产科研为一体的水泵阀门专业制造公司,公司拥有一批技术骨干和精良的生产设备,同时配备了优良的质量理人员,产品质量检测设施完善。
3. 广州市广冠水泵有限公司广州市广冠水泵有限公司(原广州市海珠水泵厂)是集产品科研、开发设计、生产、销售为一体的股份制公司,公司生产,检测设备齐全,各类专业人才济济,从产品开发设计、制造、销售和售后服务一直致力于ISO9001质量体系的建立、推广及实施。
本公司获得TSG国家特种设备(压力管道元件)制造许可证、API美国石油学会认证、国家电力公司阀门供应网络成员。
中国化工装备工业协会、机械动力技术协会、质量检测协会、机械工程学会、中国建筑金属结构协会、给排水协会、中国环保协会、消防协会、广州化工协会会员企业。
公司生产的系列阀门、给排水设备、具有新颖、高效、节能、性能独特等优点。
性能达到或接近当代国际水平。
历年荣获“重合同、守信用”单位称号,率先通过ISO9001质量体系认证,并且被评为广州市合同资信评级AAA级企业。
4. 中国有色(沈阳)泵业有限公司中国有色(沈阳)泵业有限公司成立于2009年,是中国有色矿业集团下属中国有色金属建设股份有限公司的全资子公司,是国内首台套隔膜泵设计制造者,也是中国大型隔膜泵专业研发制造企业。
中色泵业研发了具有自主知识产权的“双缸双作用、三缸单作用、四缸单作用”三大系列隔膜泵,拥有14项核心技术并获得180项专利,是固液两相介质长距离管道输送和压力喷射喂料的关键设备,广泛应用于氧化铝、煤化工、水煤浆、矿山尾矿、污泥等浆体长距离管道输送及强腐蚀、高粘度的固液两相介质输送领域。
HONEYWELL楼控部分产品型号、参数及产地产品型号说明产地监控中心基本软件EBI 基本软件 12个读卡器/250点澳大利亚EBI 基本软件 12个读卡器/500点澳大利亚EBI 扩展软件 250澳大利亚EBI 扩展软件 500澳大利亚EBI 扩展软件 750澳大利亚EBI 扩展软件 1000澳大利亚EBI 扩展软件 1250澳大利亚EBI 扩展软件 1500澳大利亚EBI 扩展软件 1750澳大利亚EBI 扩展软件 2000澳大利亚EBI 扩展软件 2750澳大利亚EBI 扩展软件 3000澳大利亚EBI 扩展软件 3250澳大利亚EBI 扩展软件 3500澳大利亚EBI 扩展软件 3750澳大利亚EBI 扩展软件 4000澳大利亚EBI 扩展软件 4250澳大利亚EBI 扩展软件 4500澳大利亚EBI 扩展软件 5000澳大利亚BA服务器附件功能软件EBI-OPDASPTS数据点分布式数据库构架软件许可澳大利亚EBI-OPALMPAG报警传护软件许可澳大利亚EBI-OPWEBTL Web Toolkit澳大利亚EBI-OPWEBPCTL Web Point Control澳大利亚工作站附件软件EBI-XXCAL附件的一个浏览器工作站软件许可澳大利亚开放式软件许可EBI-IFXLDIR Excel 5000 interface license (scantask)澳大利亚EBI-IFBACDIRCL Bacnet 客户端软件许可澳大利亚EBI-SVBACNET Bacnet 服务器软件许可澳大利亚EBI-IFOPCCL OPC 客户端软件许可澳大利亚EBI-SVOPCDAS OPC 服务器软件许可澳大利亚SWEBI-IFMODIC MODBUS 接口软件许可澳大利亚XL5000 C-BUS通讯接口Q7055A1007BNA-1C,C-Bus-网络通讯卡 (1条C-Bus)德国Q7055A1015BNA-2CS,C-Bus-网络通讯卡 (2条C-Bus)德国直接数字控制器XL800控制器。
关于DAY,CSB,TDK,ZDK系列开水器详细参数介绍DAY/CSB/ZDK等系列产品属于2001年度发行的《01S125开水器(开水炉)选用及安N72H》开水器参选产品,系由上海正水环保科技有限公司与工业设计研究院以及建筑标准设计研院根据开水器最新标准拟定的最新开水器选用标准产品。
所有产品采用最新的步进式加热技术,内置净化装置,部分产品选用膜处理技术,冷热两用。
型号解释:DAY--表示“电开水器”T81--指我是开水器序列代号,表示“标准型净化开水器”一般内置1-3级别初级净化装置(PP+UDF+CTO)T82--指我是开水器序列代号,表示“直饮水、开水两用净化开水器“一般内置5-6级净化装置(PP+UDF+CTO+UF+T33+uv杀菌)末尾数字(1-5)--指的是开水器规格序号。
---------------------------------------------------------------------------------------CSB--表示”电开水器“CSB末尾数字(4、6、9、12)--表示功率KW---------------------------------------------------------------------------------------TDK/ZDK表示”电开水器“TDK/ZDK-3、6、9、12等中间两位数表示功率KWTDK/ZDK末尾两位数字表示有效容积L。
型号有效容积(L)额定功率(KW)额定电压(V)开水产生供水功能必威尔DAY-T811353380、22036开水必威尔DAY-T81235638072开水必威尔DAY-T81350638072开水必威尔DAY-T814509380108开水必威尔DAY-T8155012380144开水必威尔DAY-T82135338036冷热两用必威尔DAY-T82235638072冷热两用必威尔DAY-T82350638072冷热两用必威尔DAY-T824509380108冷热两用必威尔DAY-T8255012380144冷热两用必威尔CSB-420422040开水必威尔CSB-650638060开水必威尔CSB-9809380110开水必威尔CSB-1210012380150开水必威尔CSB-1815018380190开水必威尔TDK6-30306380/22072开水必威尔TDK12-606012380/220144开水必威尔TDK24-10010024380288开水必威尔TDK45-20020045380540开水必威尔TDK60-30030060380720开水必威尔ZDK1.5-1313 1.522018开水必威尔ZDK3-2520322036开水必威尔ZDK6-3525638072开水必威尔ZDK7.5-50507.538090开水必威尔ZDK9-80809380108开水必威尔ZDK12-10510512380144开水必威尔ZDK15-15015015380180开水必威尔ZDK18-20020018380216开水必威尔ZDK24-24824824380288开水。
平成22年4月7日18時現在お問い合わせ等ございましたら、下記までご連絡お願い致します。
TEL 084-954-7677 CodeType有効在庫数入荷予定日区分備考<ボッシュボッシュ・・レックスロスレックスロス株式会社株式会社株式会社 製品製品>>A10VSO18DR/31R-VPA12N00-S14132LA10VSO18DFR1/31R-PPA12N000A10VO28DR/31R-PPC12N00K 1A10VO28DR/31R-PPC12N00M 1A10VO28DFR1/31R-PPC12N00M 0A10VO28DFLR1/31R-PPC12N00M 111kw-4PA10VO45DR/31R-PPC12N00M 2JGA10VO45DR/31R-PPC12N00M 2A10VO45DFR/31R-PPC12N00M 0A10VO45DFR1/31L-PPC12N00M 0A10VO45DFLR1/31L-PPC12N00M 0A10VO71DR/31R-PPC12N00M 0A10VO71DFR1/31R-PPC11N001A10VO71DFR1/31R-PPC12N00M 2A10VO71DFLR1/31R-PPC12N00M 015kw-6P A10VO71DFLR1/31R-PPC12N00M 018.5kw-6PA10VO100DR/31R-PPC12N00M 1A10VO100DFR1/31R-PPC12N00M 3A10VO100DFLR1/31R-VPC12N00M 130kw-6P A10VSO140DFR1/31R-PPB12N002A10VSO140DFLR/31R-VPB12N00430kw-6PA7VO28DR/63R-NPB011A7V80LVIRPF00/321☆フート、フランジなしA7V80LVIRPF00/332☆フート、フランジなしA7VO107LRD/63R-NPB01122kw-6P JGA7VO107LRD/63R-NPB01422kw-6P A7VO160LRD/63R-NPB010HA7VO250LRD/63R-VPB02355kw-6PA7VO355LRD/63L-VPH021A2FM-23/61W-VPB020(フートなしフランジあり)1☆A2FM250/60W-VPB021EA4VSO250DR/30R-PPB13N001K6012B02872DMP20F22B100005K6012B48942DMP20F22B110005K6013B43522DMP25F22B200005K6013B37262DMP25F22B210005K6014B44432DMP32F22B200005K6014B49752DMP32F22B21000541807350150DMP20F用ヘッドカバーA'ssy 341807350420DMP25F用ヘッドカバーA'ssy 1DMP20F用コンペセンターA'ssy 3DMP25F用コンペセンターA'ssy 1DMP20F用ブレーキ弁1DMP25F用ブレーキ弁2DMP用ブレーキ開放弁(NC)3J2020B00180MO7000-J01-104J2310C00133DB6K2-3X/31511DB10K2-3X/3155☆DB10K2-3X/2104☆DB6K2-3X/1001☆DB10K2-4X/200Y5☆41000219090RF1H32J21A1A-2 DMPカウンターバランスバルブ541000669570RF1H20J21A1A-6 DMPカウンターバランスバルブ5J8140E99212RF2E32J12A1B-J4RF2E32J12B1B-J22FRM6B36-3X/25QRV1UG461/02☆K0130A039503WE6A9-6X/EG24N9DL5K0130B036503WE6B9-6X/EG24N9DL2K0340D006304WE10D3X/CG24N9K48☆K0340D003604WE10D4X/CG24N9DL2K0340E003304WE10E4X/CG24N9DJL1K0340E039904WE10E4X/CW110N9DL1K0340T001104WE10T4X/CW100N9DJL1K0340Y004304WE10Y4X/CW200N9DL1K0130D017604WE6D6X/EG24N9DL2K0130D019404WE6D6X/EW100N9DL0K0130J019304WE6J6X/EG24N9DJL0K0130J014804WE6J6X/EG24N9DJL11K3011D002554WMM6D5X/F5K3011D330954WMM6D5X/FB101N0130F00120CA-04F-A1-3303N0140F00590CA-06F-A1-3303N0150F01060CA-08F-A1-3300N0160F01430CA-10F-A1-3303N0160F01890CA-12F-A1-3303CL-04G-A-2201☆CL-06G-A-2204☆CP3-08F-3322☆N1231A00341CP3D-04G-B-34012CP3-06G-C-3401☆DB10-2-40/1001☆DB20-2-40/1001☆DB20-1-5x/3502J0113B21010DBW10A2-5X/350-6EG24N9DL1DBW10A2-5x/100-6EG24N9DL1J0113B00590DBW10B1-5X/350-6EG24N9DL1J4011A09395DR10-4-5X/100Y0J4010A09770DR10-4-5X/315YM3J4010A12730DR10-4-5X/50YM1DR20-4-52/100Y2☆J4031A09415DR30-4-5X/100Y3J6021Z00415DZ10-1-5X/200XY1☆GPM1-AOC63B1F-1121☆GPP0-A0D40A40AL1☆GPP0-A1C50AL-1113☆GSP2-A0S08AR-AO1☆GXP0-A0C25ABR-201☆GXP0-A0C35ABL-201☆GXP0-K0A-40ABRC-211☆J0610A00230RB1-04F-C-3313J0620A01790RB1-06F-D-3313J0630A03090RB1-08F-D-3310J0640A04110RB1-10F-D-3312J0640A05030RB1-12F-D-3313J4910F03460RBE-04F-C-3305J8222A03563RDF3-06T-A-1234J8231A07982RDF3-10F-AB-1226TC-04G-3402☆TC-06F-3322☆L1421B00291Z1FS10P-A13L1411B00191Z1FS6P-A11J5510B00491Z1N6-311☆N3020D22220Z1S10D1-3X/0N3020P22870Z1S10P1-3X/3N3020T23080Z1S10T1-3X/6Z1S6T1-3X/0N3010B20250Z1S6B1-3X/1Z2DB10VC2-41/3152☆L2020B20030Z2FS10-5-3X/4L2010B20840Z2FS6-2-4X/2Q0N3120Z20370Z2S10-1-3X/1N3110Z20090Z2S6-1-6X/1J3021P21890ZDB10VP1-4X/2001J3021P22260ZDB10VP2-4X/2002ZDB6VB2-3X/2102☆J3011P25460ZDB6VP2-4X/2002J3011P25550ZDB6VP2-4X/3150J4321A05455ZDR10DA1-4X/210Y1☆J4321A05545ZDR10DA1-5X/75Y1ZDR10DA2-4X/25Y1☆J4322A12535ZDR10DB2-5X/210YM1J4323A20080ZDR10DP1-5X/25YM5J4323A20710ZDR10DP2-5X/210YM2ZDR6DA2-AX/25Y1☆ZDR6DP2-4X/25YM0J4313A21350ZDR6DP2-4X/75YM141815450150ZP10-001341815450330ZP10-003141815440120ZP6-0011☆41815440210ZP6-0022☆41815440490ZP6-0043サブプレート UG342/00411805760020サブプレート UG281/001☆↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓↓他社製品有効在庫<KYB<KYBエンジニアリングエンジニアリングエンジニアリング&&サービスサービス株式会社株式会社株式会社 製品製品>>MRH-500PW2JGMRH-500PW0無検MRH-750PW5JGMRH-1350PW3JGMRH-1350PW4無検MRH-1500PW1JGMRH-1500PW3無検MRH-2200PW1無検MRH-3150PW3無検MRH-4400PW2無検MRH2-750-1-PW1無検MRH2-1500-1-PW0無検MRH2-2200-1-PW0無検MRH2-3150-1-PW1無検MRH2-4400-1-PW1無検MRH-500PW用シールキット4MRH-750PW用シールキット2MRH-1350PW用シールキット1MRH-1500PW用シールキット6MRH-2200PW用シールキット4MRH-3150PW用シールキット2MRH-4400PW用シールキット2MRH2-750PW用シールキット2MRH2-1500PW用シールキット2MRH2-2200PW用シールキット3MRH2-3150PW用シールキット2MRH2-4400PW用シールキット4MR-750PW用シールキット1MR-1200PW用シールキット1MR-2000PW用シールキット1MR-3150PW用シールキット1ERT5UL-R 2連ケーブル20m1☆MRVSX-04A 1☆MSVSP-06C-651☆MSVSS-08A-902SS-16CB1RV 1☆RV-19☆RD-501☆RP-501☆RV-122☆ERA-4D2☆<イートンイートン機器株式会社機器株式会社機器株式会社 製品製品>>ME-4100C 2S-070DA2-K8<パーカーハネフィンパーカーハネフィン日本株式会社日本株式会社日本株式会社 製品製品>>T6CY-017-1R**-B11T6CY-022-1R**-B11C5V-086☆C5V-101☆C5V-127☆R5U-061☆R5U-083☆R5U-101☆R5V-081☆R5V-102☆<株式会社株式会社トキメックトキメックトキメック 製品製品>>FL1-20-20P-10-JA-S4M 1☆FL1-6-6W-10-JA 3☆FL1-8-8W-10-JA 1☆FL1-10-10W-10-JA 2☆SQP1-8VQ-1B23-152☆<高美精機株式会社高美精機株式会社 製品製品>>TDCV3-12-200F1☆<株式会社不二越株式会社不二越 製品製品>>CF-G06-170-201☆DMA-G01-A3X-205☆GR-G01-A2-K-201☆OCF-G03-W60-Y-J503☆OCP-G01-W1-213☆OCY-G01-P-203☆SS-G03-C5-R-C1-J212☆SS-G03-A3X-R-C1-J211OG-G03-PC-J511☆DSS-G06-C7Y-ER-C1-221☆UL-16A-20μ-IVN0☆<株式会社増田製作所株式会社増田製作所>>W-HLFS12-10P12F-NI 1☆VLR-06-20P-S 2☆VLM20DR-20P20F2☆<廣瀬廣瀬バルブバルブバルブ工業株式会社工業株式会社工業株式会社 製品製品>>HG3450-10-231☆HFPD-J10E-08-101☆<兵田計器工業株式会社兵田計器工業株式会社 製品製品>>温度計0℃~100℃1☆<竹澤工業株式会社竹澤工業株式会社 製品製品>>TCOV-10GF-20-L06-102☆<日本電熱株式会社日本電熱株式会社 製品製品>>ST-O-25072☆。
The installer should review the contents of this manual with the owner upon completion of installation, and the manual should be left with the owner and placed in a location close to the installation.IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, safety precautions to reduce the risk of fire, electric shock or injury to persons should be followed, including:1.READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER.2.This water heater must be grounded.3.Install or locate this water heater only in accordance with the provided installation e this water heater only for its intended use as described in this manual.5.Contact a qualified electrician to have unit properly installed.6.As with any appliance, close supervision is necessary when used by children.7.Do not operate this water heater if it is not working properly or if it has been damaged or dropped.8.This water heater should be serviced only by qualified service personnel.Contact a service facility for examination, repair or adjustment.9.Failure to service the anode rod at least once a year could cause the tank to fail and leak.KEEP THESE INSTRUCTIONS AT HAND SAVE THESE INSTRUCTIONS WARNING MODELGL 2.5GL 4GL 6+Capacitygallons 2.546VoltageVac 110/120 for each model Power at 120 VacWatts 150015001500Maximum Water pressurepsi 150150150WeightLbs 15.517.329.5AmperageAmps 12.50 for each model Phases 111Technical dataWARNING 3Temperature & pressure relief valve,3/4NPT male Temperature & pressure relief valve,3/4NPT male Hot water outlet Cold water inlet 1/2COMPONENT PARTS (Horizontal installation)Cold water inlet 3/4NPT male 4DIMENSIONS FOR GL 6+ (HORIZONTAL INSTALLATION)DIMENSIONS FOR GL 6+ (VERTICAL INSTALLATION)FIG.2/2FIG.2/35GL 2.5GL 414”10 1/4”12 1/4”7 1/2”3”6”31/2”1”14”51/2” 3 3/4”2 1/2”141/2”81/2”41/2”17 1/2”141/2”81/2”41/2”11 1/2”17 1/2”17 1/2”17 1/2”11 1/2”3/4N P T M A L E3”1”1/2NPT MALE3/4NPT MALE 2 1/2”6 1/2”General remarksThe manufacturer cannot be responsible for the damages caused by improper installation or by failure to follow instructions in this ply with the installation instructions before completing electric connection.The thermostat has been pre-set at the factory between 41°C (105°F) and 45°C (113°F).Hydrogen gas can be produced in a hot water system served by this heater that has not been used for a long period of time (generally 2 weeks or more).Hydrogen gas is extremely flammable.To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system.If hydrogen gas is present, there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow.There should be no smoking or open flame near the faucet at this time.CAUTIONCAUTIONCAUTION Installation instructionsFasten the supplied mounting bracket to the e screws that are suitable for the wall material and the weight of the heater.Hang the water heater on the bracket.Tug down wards on the heater to ensure that both “fingers”of the bracket are seated in the mounting slots.Confirm water piping orientation before wall mounting.Heater can sit on floor.Confirm water piping orientation before locating on floor location.The GL6+ needs to be wired with 12 GA.wire to a minimum 20 amp/ maximum 20 amp branch circuit.(Remove cover plate V (fig.3/4) using a thin screw-driver operating on point W (fig.3/4).Unscrew the screw below and lift the cover C (fig.3/4).When reassembling work in the opposite way being careful to insert first the tongue of the cover into the slot.) Insert 12 AWG through conduit at rear of heater.Secure internal wire connector below thermostat (fig.3/3) and connect wiring to right side of thermostat control.(+) to lower terminal marked “L ”, neutral to upper terminal marked “N”.Unit must be grounded T (fig.3/3).Connect the cold water inlet pipe to the inlet nipple (marked with a blue ring) and the hot water outlet pipe to the outlet nipple (marked with a red ring).The model GL 6+ can be piped horizontally from the side or vertically from the top.If you wish to install the unit horizontally, with the piping connections on the right side, you will have to be certain the tap between the two water tappings is plugged, the supplied Temperature and Pressure Relief Valve will need to be installed on top.If you wish to install the unit vertically, with the piping connections on top, you will have to be certain the tap on the side is plugged, the supplied Temperature and Pressure Relief Valve will need to be installed on top.Wall mounting (only for vertical installation)MODEL GL 6+Wiring Pipe connectionsFloor MountingThe GL 6+ water heater can be installed under the sink.Fasten the supplied mounting bracket to the e screws that are suitable for the wall material and the weight of the heater.Hang the water heater on the bracket.Tug down wards on the heater to ensure that both “fingers”of the bracket are seated in the mounting slots.Wall mounting MODEL GL 2.5 - GL 4The GL 2.5 and GL 4 water heaters can be installed under the sink.6Heater can sit on floor.Connect the cold water inlet pipe to the inlet nipple (marked with a blue ring) and the hot water outlet pipe to the outlet nipple (marked with a red ring).To reduce the risk of excessive pressures and temperatures in this water heater, install the supplied temperature and pressure protective equipment required by local codes but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shut-off Devices for Hot Water Supply Systems, ANSI Z21.22.This valve must be marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater.Install the valve in the opening provided and marked for this purpose in the water heater, and orient it or provide tubing so that any discharge from the valve will exit within 6 inches above, or at any distance below, the structural floor, and cannot contact any live electrical part.The discharge opening must not be blocked or reduced in size under any circumstances.Periodic discharge of the temperature and pressure relief valve or failure of the element gasket may be due to thermal expansion in a closed water supply system.The water utility supply meter may contain a check valve, backflow preventer or water pressure reducing valve which will create a closed water system.During the heating cycle of the water heater, the water expands causing pressure inside the water heater to increase.The temperature and pressure relief valve may discharge hot water under these conditions which results in a loss of energy and a build-up of lime on the relief valve seat.To prevent this from happening, there are two recommendations:1.Install a diaphgram-type expansion tank that is suitable for potable water on the cold water supply line.The expansion tank must have a minimum capacity of 1.5U.S.gallons for every 50 gallons of stored water.2.Install a 125 PSI pressure relief valve in the cold water supply line.Make sure the discharge of this valve is directed to an open drain and protected from freezing.Contact the local water supplier or plumbing inspector for information on how to control this situation.Do not plug the temperature and pressure relief valve.Instructions for useBefore connecting the power, fill the tank and system with water and check for leaks.To be certain that all air is out of the water system, open the hot water faucets on your fixtures until constant water flows from them otherwise damage to the element may occur.To start the heating cycle:A)first make sure tank is full.Otherwise the heating element may be damaged.B)the red light will come on and remain on until that temperature has been reached,at which point the light will go off, but will automatically come back on when the water temperature drops below the setting chosen.After installation check the water temperature.If adjustment is necessary remove front cover to adjust thermostat D (fig.3/5 - clockwise to increase the temperature and anticlockwise to decrease it).To reach the thermostat lift the plate V using a thin screw-driver operating on point W (fig.3/4).Unscrew the screw below and lift the cover C .When reassembling work in the opposite way being careful to insert first the tongue of the cover into the slot.CAUTION Closed system thermal expansion Starting and testing Temperature Setting7Pipe connectionsFloor MountingMaintenance instructionsNote:Do not attempt to repair this water heater yourself.Call a service person for assistance.Always turn off the power supply to the heater prior to servicing or draining the heater.PERIODIC MAINTENANCE AND PARTS REPLACEMENTNote:For most of these operations,the water will have to be drained from the heater.For all of these operations the power supply needs to be shut off and the front cover removed.Remove cover plate V (fig.3/4) using a thin screw-driver operating on point W (fig.3/4).Unscrew the screw below and lift the cover C (fig.3/4).When reassembling work in the opposite way being careful to insert first the tongue of the cover into the slot.1)If the heater has been installed with flexible hoses, shut off the power supply and turn the heater upside down over a sink to drain the water out of it, OR2)If the heater has been installed with rigid piping, siphon the water out through any (lower) service valve on the (inlet side).Keep a hot water faucet open while siphoning the water out, OR3)If the heater has been installed with flexible hoses, it can also be emptied by siphoning through the inlet side hose.Keep a hot water faucet open while siphoning.1.Turn off power supply and drain the heater (see previous section).2.Remove the front cover plate, disconnect terminals X , Y and T (fig.3/3).3.Unscrew the 4 heating element retaining nuts F (fig.3/3).4.Remove the element.G (fig.3/1).Scale deposits can affect the heating capability of the element.Heavy scale can even cause the element to burn out.The element can be descaled either chemically or manually:A)Soak the element in white vinegar or other descaling solution.Once descaled,rinse well with fresh water, to which you should add some baking soda, OR B)Once the element has dried up, use a soft brush (non metallic to prevent damaging the stainless steel sheath) on element.Brush the dried mineral off.Reinstall the element with gasket and make the wire connections.C)Replace anode rod if considerably shorter then diagram.WARNING:make sure the tank has been refilled with water before restoring power.The anode rod (N fig.3/2) helps protect the tank against corrosion.Depending on the water condition, the magnesium anode rod may need to be changed every year or so.Galvanic and electrolytic corrosion can destroy a tank if the anode rod is “spent”.Rusty water is usually an indication of a “spent”anode rod.If rusty water is present,examine anode rod immediately.Rapid degradation of the anode rod (less than 1year) may indicate the presence of galvanic corrosion due to “stray”direct current.In this case, it may be necessary to add a “grounding strap”from the Ariston tank to the copper plumbing.1.Turn off the power supply and drain the heater (see previous section).2.Remove heating element (see previous section).3.Remove and replace the anode rod N (fig.3/2).4.Refill tank with water before restoring power.Removing the heating element Descaling the heating elementChanging the anode rod REPLACEMENT OF PARTS8Draining the HeaterOccasionally, the high temperature limit shut off device may trigger and shut the system down.This occurs when water temperature exceeds 190°F and shuts off power to the heating element.The shut off device may also trigger from a power outage or electrical storm.To reset:1)IMPORTANT:Disconnect heater from electrical power.2)Remove front cover plate (C fig.3/4).3)Firmly press reset button (B fig.3/5).4)Replace cover plate, reconnect power.5)IMPORTANT:Check the operation of the thermostat, turn temperature dial from high to low, if the red light does not go off on low setting, turn off power supply and call a service person to replace thermostat.6)If the system works, place dial setting to desired setting.Note:a lower setting is more economical, and reduces the risk of scalding.CAUTION:Call a technician if the high limit needs to be reset frequently.Troubleshooting1.Make sure the power supply is on and working.2.If light does not come on, check that the reset button is pushed in;follow steps from previous section.3.If the indicator light works properly but temperature does not get hot a tap, test for a plumbing crossover;shut off cold supply to heater and open hot water tap.There should be no water flowing.Any continued flow indicates a crossover which will effect the temperature and will need to be corrected.4.Replace heating element (see previous section on changing the heating element).1.If the light does not come on, but water gets hot, check for faulty bulb.2.Check reset button;follow steps from previous section.1.Brown or rusty water indicates a “spent”anode rod.Replace anode rod.1.Smelly water could be due to an unusual reaction between local water and the heater’s anode rod.Check anode rod.1.Remove cover plate and turn the temperature selector dial (D fig.3/5) counter clockwise to lower temperature.If temperature never lowers then replace thermostat.1.Under Instructions for Use see Temperature Setting instruction.1.Check water fittings and T & P fitting on top of tank.2.Remove front cover and inspect heating element gasket.Water does not get hot Light not on Brown water Odor in water Water is too hot Water not hot enough Resetting High Limit SwitchLeaking91.Turn off power supply and drain the heater (see previous section).2.Remove the heating element (see section on Removing the Heating Element ).3.Install new element with gasket, making sure the gasket and element are positioned correctly.Tighten the retaining nuts and make the wire connections.4.Refill tank with water before restoring power.1.Turn off power supply.2.Disconnect the 2 push/pull type wires on thermostat.3.Loosen the two brass screws at right side of thermostat and pull wires out.4.Unscrew and remove the two phillips screws holding the thermostat down.5.Install new thermostat and re-attach wiring and screws.Changing the heating elementChanging the thermostat10G N FIG.3/1FIG.3/2FIG.3/3FIG.3/4FIG.3/5GZF X Y TVCDBF WARISTON• LIMITED6 YEARS WARRANTYCOVERAGEARISTON, THROUGH ITS U.S.DISTRIBUTOR CONTROLLED ENERGY CORP., (hereinafter CEC) guarantees this water heater to the Owner (hereinafter “Owner”) of the water heater at the original installation location against defects in material and workmanship for the periods specified below.WARRANTY PERIOD1.The inner Tank- If the inner tank leaks within six (6) years from the date of original installation of the water heater, because of a defect in material or workmanship, CEC will furnish to such Owner a new heater of the then prevailing comparable model.2.Any Component Part Other than The Original Inner Tank- If any component part (other than the inner tank) proven to be defective in material or workmanship within one (1) year from the date of original installation of the water heater, CEC will furnish the Owner with a replacement of the defective part(s).3.Verification of Date of Original Installation - When Owner cannot verify or document the original date of installation, the warranty period begins on the date of manufacture marked on the tag affixed to the water heater.EXCLUSIONS1.THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE WARRANTY MADE BY THE MANUFACTURER AND IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED(WHETHER WRITTEN OR ORAL), INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.2.The Manufacturer shall not be liable for any incidental, consequential, special or contingent damages or expenses arising, directly or indirectly, from any defect in the water heater or the use of the water heater.3.The Manufacturer shall not be liable for any water damage arising, directly or indirectly, from any defect in the water heater component part(s) or from its use.4.Manufacturer shall not be liable under this warranty if:a) The water heater or any of its componentparts has been subject to misuse, alteration, neglect or accident, orb) The water heater has not been installed inaccordance with the applicable local plumbing and/or building code(s) and/or regulation(s), orc) The water heater has not been installed inaccordance with the printed manufacturer’s instructions, ord) The water heater is not continuouslysupplied with potable water.5.The OWNER and not the Manufacturer or his representative shall be liable for and shall pay for all field charges for labor or other expenses incurred in the removal and/or repair of the product or any expense incurred by the owner in order to repair the product.SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STA TE TO ST ATE.IMPORTANT:OWNER SHALL KEEP THISMAKE A CLAIMNOTE:A water heater should be installed insuch a manner that if it should leak, the resulting flow of water will not cause damage to the area in which it is installed.HOW THE OWNER CAN SECURE SERVICEOR MAKE A CLAIM1.Owner should contact the dealer who sold the water heater covered by this warranty or2.Owner should submit the warranty claim directly to CEC at the address listed below, and they will arrange for the handling of the claim3.Whenever any inquiry or service request is made, be sure to include the water heater model number the date of manufacture , date of installation, Dealer’s name and the watts and voltage.4.When returning the water heater or component part(s), they must be individually tagged and identified with the Returned Goods Authorization # issued by CEC and shipped prepaid to CEC at the address below.Controlled Energy Corp.340 Mad River ParkWaitsfield, VT 05673800-642-3111802-496-4436Fax 802 496-6924 COMMON SENSE HEAT & HOT WATER TECHNOLOGYMTS MAKES USE OFRECYCLED PAPER29.1.60.542.1.01 0900 L i t o g r a f s .r .l.Controlled Energy Corp.340 Mad River Park Waitsfield, VT 05673800-642-3111802-496-4436Fax 802 COMMON S ENSE H EAT & H OT W ATER TECHNOLOGYMerloni TermoSanitari SpA Viale Aristide Merloni, 4560044 Fabriano (AN)Tel. 0732.6011Telefax. 0732.602331Telex 560160。
产品名称:ES-R120水胆容量:热水箱:8L 冷水箱:8L功率:12KW产水量:160L-180L/H外型尺寸:400*440*1440mm电源:380V/50Hz额定电流:18.2A电源接口:三相四线(可选配三相五线)水源接口:三分(机器标配:四转三接头及1.5-2米3分PE管)进水压0.15-0.35mpa产品核心主件:水控机:配套开水器主机使用的消费扣费控制器,可按时间计费和按流量计费,可脱机连接和联网连接。
充值机:用于脱机方式进行对用户卡的充值,数据采集、可便携式移动的终端充值器。
IC卡:分为用户卡、设置卡、初始化卡、采集卡等,可作为一卡通使用。
节能管理软件:分为脱机软件以及联网软件,用于开户、销户、充值、客户资源管理等。
注:以上产品可兼容目前市场上98%以上节水控制器,完成与高校原有的一卡通系统对接,目前成功对接的一卡通水控厂家有深圳凯路创新、深圳好年华、深圳领路达方、新中新牌、新开普牌、嘉亮牌、南京理达、四浪科技牌、以及电信集团配套的一卡通系统等。
(可选择脱机和联网方式)产品功能介绍:加热系统:采用热推式技术原理,冷热交换技术,系统冷水控制技术,消除传统电动阀控制热水结垢难题;应用冷热推水技术,使流出的开水经过交换释放热量而让进来的冷水在进入开水器之前吸收热量预热提升温度,从而极大限度地节省将水烧开所需的电能和时间,大大提升加热效率。
水控系统:连接开水器主机电脑板,集成热推式技术,外嵌(内嵌)开水器显示屏下方,用于扣取水费的作用,采用特有三联取水阀以及双水箱设计,同时打开或者关闭进水与出水技术,并采用安全溢气回流,使水胆的压力平均,从而杜绝了水压不均,大大提升水流量计时收费的准确度,是目前最先进的计费系统。
充值系统:通过卡系统软件对IC卡用户进行分类建档、发卡激活,用户可通过简易充值机按需对IC进行充值,无须配备电脑从而免去使用软件的繁杂,通过键盘即可设置系统密码钥及费率卡的制作。