浅谈别墅中央空调系统的设计与应用摘要:以特定业态—别墅为例,针对几种常见的中央空调设计

方案,经过对其系统设置、工程造价及运行费用等方面比较,分析其优缺点,总结了在别墅中央空调系统设计时应考虑的问题。

关键字:中央空调;冷、热源;系统形式;优、缺点

abstract: in a specific format-villa as an example, this paper several common central air-conditioning design, through the system settings, the project construction cost and operation cost, compares and analyzes their advantages and disadvantages, and summarizes the villa in the central air conditioning system design should be considered when the problem.

key words: the central air conditioning; cold, heat source; the system form; advantages and disadvantages

中图分类号:tu831.3+5文献标识码:a文章编号:

经济的快速腾飞发展,在提高人们的物质生活水平的同时,也

在不断改善人们的住房条件。大面积多居室的住宅拔地而起,别墅作为其奢侈品应运而生。现今人们对居室装潢布置提出要求的同时,对居住环境的舒适性也提出了更高的要求,因此,现中央空调已成为别墅的必需品。

一、别墅中央空调的几种形式与应用分析

中央空调工程施工设计方案

第一章工程概况 一、工程概况 (一)基本情况 本工程位于市黄孝河路,建筑面积约10000平方米,地上8层,地下一层,建筑高度30米。本施工组织设计容为该大楼的空调系统、通风系统和防排烟系统。 (二)空调系统设计参数 夏季空调室外计算参数:干球温度35.2℃ 温球温度28.2℃ 夏季通风室外计算相对温度:63% 冬季空调室外计算参数:干球温度-5℃ 冬季室外计算相对湿度:76% 本工程选用的冬、夏季室设计参数如下表。 (三)系统概述 1.冷热源方式

选用欧威尔水源热泵螺杆式主机集中供冷、热源。 2.空调及采暖负荷:设计日冷负荷1400KW,冬季空调热负荷810KW,卫生热水290KW。 (四)通风及防排烟系统 主要为地下室通风、排风系统以及电梯前室加压送风系统。火灾时,消防控制中心指令打开或手动打开着火层及其上下层常闭风口,输出动作电信号,同时打开所有的加压送风机。 二、施工要点与重点 该分项工程的要点如下: 1.主机的就位及安装 2.水泵的安装 3.冷却塔的安装 4.支吊架制作安装 5.风管制作 6.风管系统安装 7.管井空调水立管施工 8.空调水系统水压试验、冲洗、防腐及保温 9.风机盘管、新风机、空调机组等空调设备安装 10.自控系统安装 11.单机试运转、设备试运转及联合调试 12.空调系统保养

第二章编制依据和采用标准及规 一、编制依据 1.长江水利委员会长江医院空调工程招标文件。 2.水利委员会长江勘测规划设计研究院的长江医院及血防监测中心还建工程图纸。 3.本单位《项目法管理实施细则》。 4.我公司对该工程优化设计方案。 二、采用标准及规: GB50243-2002 《通风与空调工程施工及验收规》 GB50242-2002 《采暖与卫生工程施工及验收规》 GBJ50274-98 《制冷设备、空气分离设备安装工程施工及验收规》GBJ50275-98 《压缩机、风机、泵安装工程施工及验收规》GB50302-2002 《建筑安装采暖卫生与煤气工程质量评定标准》GB50304-2002 《通风与空调质量评定标准》 GB50235-97 《工业金属管道工程施工及验收规》 GB50236-98 《现场设备、工业管道焊接工程施工验收规》GB50231-98 《机械设备安装工程施工及验收通用规》

中央空调毕业设计论文

毕业设计(论文) 题目名称:惠新大厦中央空调系统设计 学院名称:能源与环境学院 班级:建环 学号: 学生: 指导教师: 年月日

论文编号: 惠新大厦中央空调系统设计 专业:建筑环境与设备工程:教导老师: 摘要 本设计为惠新大厦中央空调设计。通过方案比较,在负荷计算的基础上,采用了风机盘管加新风和全空气两种空调系统形式。一层除了有单独办公室,还有一个长17.8m,宽15.6的办公大厅,不适合用风机盘管加新风系统,选用全空气系统。二层到十层楼层,大部分为单独办公室,所以全部选用风机盘管加新风系统。风机盘管为卧式暗装,新风不承担室负荷;全空气系统为一次回风系统,室送风采用散流器下送方式。新风从墙洞引入,再由各层的新风机组集中处理供应。冷冻水由地下室的冷冻机房供应,采用了闭式同程两管制水系统。水管用泡沫橡塑保温,风管采用离心玻璃棉。设计工程中考虑了消声、减振措施。 关键词:中央空调,风机盘管加新风系统,全空气系统,大厦

Central Air-conditioning Design for HuiXin Building Abstract The air conditioning engineering of Huixin Building was designed. On the base of cooling load, heating and moisture load calculation, primary air fan-coil system and all air system are adopted by way of technical and economic analysis. In addition to individual office level, there is a length 17.8m, width of 15.6 in the office lobby, not suitable for fan coil plus fresh air system, use an all air system. The second floor to ten floors, most as a separate office, so all the fan coil selection of a new air system.The fresh air doesn’t undertake indoor load and delivers air through double deflection grille after mixing the return air in the horizontal recessed fan coil. The return air is harnessed one time by the air handling unit in the all air system and the handled air is delivered through double deflection grille by sidewall air supply. The fresh air is supplied by hole or shaft and handled by the fresh air handling unit. The chilled water which is a closed two-pipe direct return water system is supplied by the refrigerating plant room. The thermal insulation material of water pipe and air duct are foam plastics and centrifugal glass wool respectively. Measures of noise elimination, damp, fire prevention and smoke extraction is considered during the design. Key Words: air conditioning primary air fan-coil system all air system building.

暖通空调系统设计手册完整版

暖通空调系统设计手册 目录 第一章设计参考规范及标准.................................................. 错误!未定义书签。 一、通用设计规范:....................................................... 错误!未定义书签。 二、专用设计规范:....................................................... 错误!未定义书签。 三、专用设计标准图集:................................................... 错误!未定义书签。第二章设计参数............................................................ 错误!未定义书签。 一、商业和公共建筑物的空调设计参数ASHRAE ................................ 错误!未定义书签。 二、舒适空调之室内设计参数日本.......................................... 错误!未定义书签。 三、新风量............................................................... 错误!未定义书签。 1、每人的新风标准ASHRAE ............................................... 错误!未定义书签。 2、最小新风量和推荐新风量UK ........................................... 错误!未定义书签。 3、各类建筑物的换气次数UK .......................................... 错误!未定义书签。 4、各场所每小时换气次数................................................ 错误!未定义书签。 5、每人的新风标准UK ................................................... 错误!未定义书签。 6、考虑节能的基本新风量(1/s人)(日本) ................................ 错误!未定义书签。 7、办公室环境卫生标准日本............................................ 错误!未定义书签。 8、民用建筑最小新风量.................................................. 错误!未定义书签。第三章空调负荷计算........................................................ 错误!未定义书签。 一、不同窗面积下,冷负荷之分布% .......................................... 错误!未定义书签。 二、负荷指标(估算)(仅供参考).......................................... 错误!未定义书签。 三、空调冷负荷法估算冷指标。空调冷负荷法估算冷指标(W/M2空调面积)见下表 . 错误!未定义书签。 四、按建筑面积冷指标进行估算建筑面积冷指标......................... 错误!未定义书签。 五、建筑物冷负荷概算指标香港............................................. 错误!未定义书签。 六、各类建筑物锅炉负荷估算W/M3℃......................................... 错误!未定义书签。 七、热损失概算W/M3℃..................................................... 错误!未定义书签。 八、冷库冷负荷概算指标................................................... 错误!未定义书签。第四章风管系统设计........................................................ 错误!未定义书签。 一、通风管道流量阻力表................................................... 错误!未定义书签。 1、缩伸软管摩擦阻力表.................................................. 错误!未定义书签。 2、镀锌板风管摩擦阻力表................................................ 错误!未定义书签。 二、室内送回风口尺寸表................................................... 错误!未定义书签。 1、风口风量冷量对应表.................................................. 错误!未定义书签。 2、不同送风方式的风量指标和室内平均流速ASHRAE ......................... 错误!未定义书签。 三、室内风管风速选择表................................................... 错误!未定义书签。 1、低速风管系统的推荐和最大流速m/s .................................... 错误!未定义书签。 2、低速风管系统的最大允许速m/s ........................................ 错误!未定义书签。 3、通风系统之流速m/s .................................................. 错误!未定义书签。 四、室内风口风速选择表................................................... 错误!未定义书签。 1、送风口风速.......................................................... 错误!未定义书签。 2、以噪音标准控制的允许送风流速m/s .................................... 错误!未定义书签。 3、推荐的送风口流速m/s ................................................ 错误!未定义书签。 4、送风口之最大允许流速m/s ............................................ 错误!未定义书签。

暖通毕业设计开题报告

题目:永州商业广场综合楼中央空调系统设计 学院:建筑工程学院 专业:建筑环境与设备工程 学生姓名: xx 学号: 201209010114 指导老师: xxx 2016年3月30日

开题报告填写要求 1.开题报告(含“文献综述”)作为毕业设计(论文)答辩委员会对学生答辩资格审查的依据材料之一。此报告应在指导教师指导下,由学生在毕业设计(论文)工作前期内完成,经指导教师签署意见及所在专业审查后生效。 2.开题报告内容必须用黑墨水笔工整书写或按此电子文档标准格式(可从教务处网页上下载)打印,禁止打印在其它纸上后剪贴,完成后应及时交给指导教师签署意见。 3.“文献综述”应按论文的格式成文,并直接书写(或打印)在本开题报告第一栏目内,学生写文献综述的参考文献应不少于10篇(不包括辞典、手册),其中至少应包括1篇外文资料;对于重要的参考文献应附原件复印件,作为附件装订在开题报告的最后。 4.统一用A4纸,并装订单独成册,随《毕业设计(论文)说明书》等资料装入文件袋中。

毕业设计(论文)开题报告 文献综述 一、引言 随着我国人民生活水平的不断提高,购买力增强。近年来修建了不少商业建筑,并且向多元化方向发展,建筑规模越来越大。装饰豪华、营销全面、多维服务,集商贸、娱乐、居住、办公为一体的高级商城也层出不穷。 商业建筑是一个流动人口众多的公共场所,室内空气的温湿度、洁净度和新鲜空气量等,对顾客和商场职工的身体健康影响很大。因此,商业建筑的空气环境越来越被商业部门所重视。我国卫生防疫部门对商业建筑提出了卫生要求,对较大的重点商场还进行过监测,对一些已建的大中商场要求进行改造,增设通风设施或加建空气调节装置。新建的大中商业建筑纷纷安装了空调系统,以提高商场的档次,吸引更多的顾客。各大城市中频频展开的“商战”更加速了空调系统在商业建筑中的普及。 商业建筑不断的增多,以及人们对室内空气的温湿度、洁净度和空气品质问题越来越重视,加上能源的紧缺,节能问题越来越引起人们的重视。因此迫切需要为商业建筑物安装配置节能、健康、舒适的中央空调系统来满足人们对高生活水平的追求。目前,随着我国经济的快速增长,生活条件日益改善,人们对生活环境的舒适性的要求越来越高,对中央空调的需求越来越大,对中央空调节能、舒适、健康更加关注。 国际标准规定,商用空调是3HP以上空调机组的统称,因此商用空调种类颇多。包括风冷热泵型中央空调机组,水冷螺杆式冷水机组、离心式冷水机组等等。 因此,设计一项节能、舒适、健康的中央空调工程是很有实际意义的。 二、研究现状 中央空调在世界上已有百年的发展历史,在中国也有20多年的应用时间,然而真正引起国内企业关注还是近几年。目前国内市场中央空调领域竞争已经进入白热化阶段,随着价格战连绵不断,在家用空调领域几乎已经无利可图的企业纷纷开始在中央空调领域寻找新的发展空间和利润增长点。 2003年中央空调市场容量将达到85亿元,2005年达到200亿元以上。市场空间迅

暖通空调毕业设计开题报告

1.课程设计的意义 通过本次的课程设计,使自己拥有一定的暖通空调设计能力;了解一些相关的规范和条例;熟悉并掌握暖通空调设计流程;同时使自己的思维更加的严谨,态度更加的认真,为以后的社会工作奠定了扎实的基础。 2.文献综述 随着国民经济的快速持续发展,作为支柱产业之一的建筑业也得到迅猛发展。而作为建筑业的重要组成部份的暖通空调业,其新产品、新技术、新材料更是层出不穷。暖通空调业发展所遵循的原则,概括起来就是:节能、环保、可持续发展,保证建筑环境的卫生与安全,适应国家的能源结构调整战略,贯彻热、冷计量政策,创造不同地域特点的暖通空调发展技术。因此,如何结合设计的需要,重视相关技术,并有选择而合理的应用在我们的设计中,满足业主要求,提高设计水平,是我们必须努力做到的。 2.1.暖通空调变工况点优化控制及能量管理探讨 2.1.1.工况点优化控制 暖通空调变工况点优化控制问题的研究近年来在我国被重视。S.W.Wang 提出了一种基于整个系统环境的预测响应及能量运行来改变暖通空调系统控制,设定点的系统方法,并用遗传算法对系统进行优化控制,同时优化多个设定点来改善系统响应和降低系统能耗[1],后来他又采用自适应性控制理论对某海水冷却。空调系统进行了优化控制研究,采用带指数遗忘的最小二乘法参数辨识方法和基因遗传优化算法,对空调系统的空气处理单元进行了优化控制研究[2]。罗启军等人提出了一项动态的优化技术在一个指定期间内,能得到使目标函数( 运行成本或者峰值能耗) 最小的房间温度曲线,该算法还给出了暖通空调设备的最佳开/关时间[3]。K.T.Chan 等人提出用遗传算法对风冷制冷机的冷凝温度设定点进行优化控制以提高制冷机的效率[4]。此外,有许多研究者用人工神经网络来模拟暖通空调系统中各个设备的非线性特性,用于实现对整个空调系统的优化控制。目前,研究者们将更多先进的建模方法和智能优化方法引入到了暖通空调的优化控制中,更加注重变工况点的在线优化控制。何厚建等人对已建的暖通空调各关键设备的静态模型采用用实数编码的遗传算法建立了水系统工作点优化控制策略[5]杨晓平等人采用模糊聚类和RBF方法建立了空气处理单元的动态数学模型,以最终舒适性为目标优化空气处理单元的温湿度和送风压力[6]。孙一坚根据空调负荷变化对一级泵水系统进行变流量控制,取得了显著效果[7]。总之国内的学者更多探讨的是把智能方法引入控制系统的优化中,仿真研究多,实践成果少。

中央空调系统设计毕业论文

(此文档为word格式,下载后您可任意编辑修改!) 摘要 本工程为苏州市一酒店大楼,拟为之设计合理的中央空调系统,为室内工作人员提供舒适的工作环境。 设计内容包括:空调冷热负荷的计算;空调系统的划分与系统方案的确定;冷源的选择;空调末端处理设备的选型;风系统的设计与计算;室内送风方式与气流组织形式的选定;水系统的设计、布置与水力计算;风管系统与水管系统保温层的设计;消声防振设计等内容。 本设计依据有关规范考虑节能和舒适性要求,设计的空调系统采用风机盘管——新风系统。 关键词:酒店;中央空调;风机盘管——新风系统。

ABSTRACT This project designs on air-conditioning system for a hotel Building in Beijing.By comparing the advantages and disadvantages of the air-conditioning program and the suitable situation, combined with the actual situation and the data in this paper,selecting the appropriate type of air conditioning systems to meet the indoor staff comfortable working environment, and determining the design system. According to the relevent norms and the requirements of energy conservation and comfortableness, all-air primary return air system and the fan-coil unit plus fresh air system are applied to the central air conditioning system, respectively, based on the using function of the building. And both systems are designed, analysed, and calculated,separately. Based on this, the air conditioning wind, water systems and chiller plant are designed. The design contents include: the consultation of the relevant material; the understanding of the design principles of the air conditioning system in high-rise complex building; the determination of the indoor and outdoor design parameters; the calculation of the air-conditioning cooling load; the demonstration and selection of cold and heat source; the calculation of the air-conditioning cooling load; the lectotype of the air terminal processing equipment; the selection of the indoor air supply pattern and air distribution form; the selection of the indoor air form of organization ; the design and accommodate of the vault ventilation system; the design, layout and calculation of the water system; the determination of the type of insulation material; the depiction of the clear engineering drawings. Key words: hotel Building All-air system Fan-coil unit plus fresh air

建筑项目暖通空调系统设计

建筑项目暖通空调系统设计 摘要:暖通系统是伴随建筑整个生命过程中必不可缺的一个组成部分,暖通系 统的节能设计是在建筑工程施工中至关重要的环节,合理的节能设计不但能为建 筑节省一大笔费用,还是减少资源浪费和环境污染。因此,在暖通系统的节能设 计中,设计员应该给予足够的重视,利用科学的方法,结合工程的实际情况,设 计出合理、可操作的设计方案,以实现暖通空调的节能设计经济、节能、安全等 目的,促进中国建筑行业的健康发展以及能源的可持续发展。 关键词:建筑工程;项目;暖通空调;设计 在我国城市化建设的不断发展下,对建筑的舒适度要求越来越高,暖通空调 已经成为现代建筑中非常重要的设施。在民用建筑暖通空调设计的过程中,如何 进行空调负荷的设计,如何选择空调水泵,如何对能源进行选择利用,以提高能 源的使用效率,如何在创造出舒适的室内环境时避免对室外环境造成过多的不良 影响,已成为设计中需要重点解决的问题。 1 设计前的准备工作 1.1 分析建筑物外部环境和内部环境 在进行暖通空调设计前,要对建筑周围的外部环境和基础设施的埋设方式进 行全面分析,以设计合理的供热入口;在设计空调负荷时,要综合考虑高度、日照、风力等外部环境因素,结合室内人员、设备、照明等内部环境因素,按照设 计步骤逐步计算,最终得到切合建筑物实际负荷特性的空调设计负荷。 1.2 分析建筑物内部使用情况 要对建筑物的基本使用情况、人员居住的具体数量、废气排放基本情况等进 行考虑,在充分了解建筑内部的相关情况后,通过计算得出各不同区域实际的运 转负荷,以便对暖通空调系统进行合理分区。 1.3 划分防烟区和防火区 由于建筑的楼层数量比较多,一旦发生火灾,如果不能及时对居民进行疏散,会造成严重的安全事故。因此在设计时,要划分具体的防烟区和防火区,要对防 火区、防火墙、防烟区进行合理的设计,确保有火灾发生时,人们可以在最短的 时间内逃离事故现场。 2 设计中的几个关键点 2.1 空调负荷设计 在《采暖空调制冷手册》和《制冷与空调技术手册》中指出,商用建筑夏季 的冷负荷概算指标为210w/m2 ~ 240w/m2,旅馆办公类的冷负荷指标为 94w/m2 ~ 163w/m2。但是在具体的设计过程中,会由于一些问题导致空调装机 容量增加,导致空调系统初期的投资金额增加。一是在设计空调系统时,个别设 计人员只是使用负荷指标估算的方法进行计算,导致制冷机的装机容量增加,造 成了不必要的投资浪费,严重时会对部分负荷下的冷机效率造成影响;二是在设 计的过程中,考虑各种安全系数,导致空调单位制冷面积超出手册中冷负荷概算,超过了实际运行过程中单位空调面积的峰值冷量。从全年的角度来看,建筑负荷 真正处于峰值的时间并不长,因此在大多数时间段,冷机负荷率是处于一种比较 低的状态,COP 并不高。根据经验,一般办公室单位冷负荷指标取70W/m2 ~ 90W/m2,商场单位冷负荷指标取100w/m2 ~ 150w/m2 之间就可以达到日常使用要求(均指建筑面积)。 2.2 选择空调循环水泵

别墅型建筑中央空调设计及施工中的几点体会

别墅型建筑中央空调设计及施工中的几点体会 陈文博,陈明款 (广东省工业设备安装公司,广东广州510260) 摘 要:介绍了别墅型建筑中采用风冷热泵中央空调系统时,在主机和末端设备的选择、安装、机组运行调节方面的有关要求和注意事项。 关键词:冷负荷指标;供冷机组;循环水泵;压缩机 中图分类号:T U241.1:T U831.3.1 文献标识码:B 文章编号:1002-3607(2002)01-0022-01 近年来,以风冷热泵为代表的小型中央空调系统以其特有的优势,在别墅型建筑中得到了迅猛的发展。其主要特点是一机多用———夏季制冷、冬季采暖;采用空气冷却,无需冷却塔等设备;配套有自动化控制系统,操作简单,安装方便。笔者在参与广州某别墅群设计及施工过程中的几点体会可供同行参考。 1 主机及末端设备的选择 别墅的人员密度相对较小,冰箱、炉灶等也不会放于空调房间内,其房间的冷负荷指标略低于普通住宅,在广州地区可按100~120W/m2来计算,采用风冷热泵作为主机能够为空调系统提供的热水一般在45~50℃左右,与通常60℃的采暖热水温度相比有较大差距,选择末端设备时应特别注意这一点。因此,在设计时也应引起重视,可以通过放大一级盘管的方法来解决,并且放大一级盘管对工程造价也不会产生很大的影响。 别墅的房间主要由客厅、餐厅、卧室、书房及娱乐室等构成,同时使用率较低,一般只有50%~60%,所以可以按照房间总负荷的55%~65%来确定主机的负荷。别墅面积较大、功能房间较多的选下限值,反之应选上限值。 目前市面上的风冷热泵小型空调主机分为直接供冷和间接供冷两大类。直接供冷通过制冷剂(俗称雪种)在末端设备直接蒸发来调节室内温度。该类主机普遍采用变频技术,主要优点是高效节能,其变频技术可使机组长期处于满负荷工作状态,并可实现多达二十几级的能量调节,与普通机组相比可节省电力40%~50%;但其缺点是初投资过高。在广州地区,采用该类设备的别墅,空调工程每平方米造价约为600~700元,一般业主难以接受。而采用冷冻水为载冷剂的间接供冷机组,虽然其能量调节范围相对较小,但胜在价格便宜,采用该类设备的别墅,空调工程每平方米造价仅为300~350元(包括含直接费及间接费,为工程结算价)。本公司在广州市某大型别墅群的设计及施工中也是采用该类机组,使用效果良好,运行也很稳定。 2 安装施工中应注意事项 (1)施工单位在图纸会审时,必须清楚机组的安装位置是否合适。因为建筑师在考虑建筑外形效果的时候,设计出的别墅屋顶往往是红瓦或蓝瓦的斜屋顶,而空调设计人员考虑到膨胀水箱需高于冷冻水管1m,常将水箱布置于屋顶上,这显然是无法安装的。如果将水箱放在别墅顶层,又没有足够的层高。因此可建议业主和设计人员选用内置定压膨胀水箱的机组,该类水箱有别于传统的膨胀水箱,它不受安装高度的影响,给施工带来了很大的方便。 (2)目前的机组普遍内置有循环水泵,整机出厂,大大提高了安装的速度。但是有些机组的水泵扬程较小,如Y ORK和Y C AC系列机组,其内置的水泵扬程仅5.5m,因此,不但设计人员要认真校核水泵扬程是否足够之外,安装单位也必须结合现场合理布置好管线,尽量减小局部阻力。 (下转第25页) 22安 装 2002年2月

暖通空调毕业设计(论文)任务书

毕业设计(论文)任务书 毕业设计(论文)题目:某市某综合楼空调系统设计 系别能源与动力学院班级建环本121/122 学生姓名学号 指导教师职称 毕业设计(论文)进行地点:校内 任务下达时间: 2015年 12 月 24 日 起止日期:2016年 3 月1日起——至 2016年 6 月日止 教研室主任年月日批准 1、论文的原始资料及依据:

(一)题目来源:某市某综合楼建筑结构图 (二)设计主要技术参数 (1)土建资料 详见建筑图纸。 (2) 气象参数:根据本市的气象资料确定; (3)建筑参数: 外墙体结构:根据地区自行选定,如δ=370 m m红砖,内外抹灰20mm 屋面:根据地区自行选定,如200mm厚混凝土板加12.5mm厚加气混凝土保温层。 外窗:根据地区自行选定,如标准玻璃的单层钢窗,全部挂淡色窗帘,(4)室内空调设计参数:温度t n=26℃; 湿度φn=60%; 风速不大于0.3 m/s。 (5)照明容量: 40W/m2 (6)房间人数:0.5人/m2,群集系数0.92 (三)设计主要技术关键 正确进行空调负荷和新风量的计算,确定出冷气方案,合理地布置管道,并进行水力计算,合理选择及布置设备,做好气流组织。 2、设计(论文)主要内容及要求 通过本次设计使学生系统地掌握空调系统设计的主要方法和步骤,能根据实际情况合理确定空调方案,会计算空调系统的负荷量和新风负荷量,能合理布置管道和设备,了解空调设备的型式及用途,会进行设备的选型,合理进行气流组织,会计算水管、风道的阻力,选取水泵、风机等。使学生能把所学知识灵活运用到实际当中去,让理论与实际相结合,为学生毕业以后的工作打下坚实基础。 主要内容: 空调系统的设计 (1)、由建筑物所在地区确定室内外气象参数; 夏季室内外设计计算参数;室内温度、湿度、风速、新风量等参数。

空调系统毕业论文

南京铁道职业技术学院毕业论文 题目:苏州大学实训楼中央空调系统 作者:尹啸东学号: 421111146 系部:建筑设备工程系 专业:楼宇智能化工程技术 班级: 11宁系统维检301 指导者:刘光平讲师 评阅者: 2013 年 10 月

毕业设计中文摘要

毕业设计外文摘要

目录 1 引言 (5) 2 设计概况 (6) 2.1 概况 (6) 2.2 本毕业设计课题任务的要求 (7) 2.3 设计原始资料 (7) 3 空调系统 (8) 3.1 空调系统的基本定义 (8) 3.2 空调系统方案的确定 (9) 3.3 新风系统的监视与控制 (10) 4 新风系统 (14) 4.1 新风机组的设计要求.............................................. - 14 - 4.2 风机盘管机组的选型.. (14) 4.3 新风系统的监视与控制 (16) 5 空调水系统设计 (17) 5.1 选择水系统形式 (17) 5.2 选择管材和管道直径 (17) 5.3 水系统管路的布置 (18) 5.4 空调水量计算及泵扬程 (19) 6 空调冷热源系统 (20) 6.1 冷源系统 (20) 6.2 热源系统 (24) 7 ......................................................................... 7 ........................................................................ 结论....................................................................... 致谢....................................................................... 参考文献................................................................... 附录A 各房间最大热湿负荷汇总............................................................................................

三层别墅中央空调系统毕业设计

三层别墅中央空调系统毕业设计 目录 第1节前言 1.1 家用小型中央空调的发展现状 (1) 1.2 外国家用小型中央空调发展现状 (1) 1.3 中国家用小型中央空调发展现状 (2) 1.3.1中国家用小型中央空调发展情况与国外的对比 (2) 1.3.2中国小型中央空调发展前景 (2) 1.3.3中国小型中央空调的优势 (3) 1.4家用中央空调的分类 (3) 1.4.1风管机 (4) 1.4.2冷热水机 (4) 第2节建筑信息 2.1 建筑概述 (6) 2.2地理位置 (6) 2.3计算参数 (6) 2.3.1建筑平面图 (6) 2.3.2室外计算参数 (6) 2.3.3室计算参数 (7) 2.4 建筑围护结构信息 (7) 2.5设计依据 (7) 第3节负荷计算

3.2 冷负荷系数法公式 (8) 3.3 负荷计算 (9) 3.3.1 外墙和屋面瞬变传热引起的冷负荷 (9) 3.3.2 墙,楼板等室传热维护结构形成的瞬时冷负荷 (9) 3.3.3 外玻璃窗瞬变传热引起的冷负荷 (10) 3.3.4 透过玻璃窗的日射得热引起的冷负荷 (11) 3.3.5 设备散热形成的冷负荷 (12) 3.3.6 人体散热形成的冷负荷 (12) 3.3.7 门引起的冷负荷 (13) 3.4负荷汇总 (13) 第4节空调系统方案的确定 4.1空调系统设计的基本原则 (16) 4.2空调系统方案的比较 (16) 第5节空调系统的计算 5.1风机盘管加新风空调系统选型计算 (19) 5.1.1 风机盘管处理过程 (19) 5.1.2风机盘管加新风系统设计 (20) 5.2新风机组的选型 (22)

(完整版)三层别墅中央空调系统说明书毕业设计

以下文档格式全部为word格式,下载后您可以任意修改编辑。 河南机电高等专科学校毕业设计 说明书 设计题目:三层别墅中央空调系统 系部 专业 班级 学生姓名 学号 指导教师 摘要 家用中央空调是指根据国家空调设计规范的设计参数和要求进行选型

设计、安装的,用于家庭的空调系统。家用中央空调是由室外主机、室内风机盘管及其连接的风道送出冷热风以达到室内空气调节目的的空调系统,按工作原理可分为二种:一种是由大型中央空调系统的设备演化而来的空调系统如小型风冷冷水机组,小型风管机组为主机的产品;另一种是由分体壁挂空调设备演化而来的空调系统如一拖小型风管机组属集中中央空调系统,此系统由室外机组,室内风机盘管及盘管连接的送风管道组成。送风管道通向各个需要空气调节的房间,风道系统可安装流量调节阀、风口等配件,一台主机可控制多个不同房间并且可引入新风,有效改善室内空气品质。 步入21世纪,人们对生活品质要求不断提高,住宅面积不断地扩大,以窗机、分体挂壁机和柜机为代表的传统的家用空调已不能充分满足环境、能源的需要。目前家用空调市场上的产品,从严格意义上讲只能称为“温调”,真正的”空调”应具备空气质量调节的功能,不仅调节空气冷暖,而且可以通风换气,调节空气湿度、有机挥发物含量、细菌含量等室内空气的综合品质。从这个意义上,家用中央空调才把人们带入到“真正的空调时代”。这种集大型中央空调和家用空调优点于一体的小型化独立空调系统恰到好处地适应了目前市场的需求,代表了21世纪人居空调的发展趋势,更重要的是,它跨越了我国空调产业长期以来存在的“中央空调”与“家用空调”间的界限,开辟出了一个崭新的市场空间。 关键词:工作原理系统分类中央空调的现状前景家用中央空调的 发展趋势 Summary Home central air conditioning is based on the design parameters of

工商银行杭州支行办公楼空调工程设计暖通空调毕业设计论文

中国工商银行杭州支行办公楼空调工程设计

毕业设计(论文)原创性声明和使用授权说明 原创性声明 本人郑重承诺:所呈交的毕业设计(论文),是我个人在指导教师的指导下进行的研究工作及取得的成果。尽我所知,除文中特别加以标注和致谢的地方外,不包含其他人或组织已经发表或公布过的研究成果,也不包含我为获得及其它教育机构的学位或学历而使用过的材料。对本研究提供过帮助和做出过贡献的个人或集体,均已在文中作了明确的说明并表示了谢意。 作者签名:日期: 指导教师签名:日期: 使用授权说明 本人完全了解大学关于收集、保存、使用毕业设计(论文)的规定,即:按照学校要求提交毕业设计(论文)的印刷本和电子版本;学校有权保存毕业设计(论文)的印刷本和电子版,并提供目录检索与阅览服务;学校可以采用影印、缩印、数字化或其它复制手段保存论文;在不以赢利为目的前提下,学校可以公布论文的部分或全部内容。 作者签名:日期:

学位论文原创性声明 本人郑重声明:所呈交的论文是本人在导师的指导下独立进行研究所取得的研究成果。除了文中特别加以标注引用的内容外,本论文不包含任何其他个人或集体已经发表或撰写的成果作品。对本文的研究做出重要贡献的个人和集体,均已在文中以明确方式标明。本人完全意识到本声明的法律后果由本人承担。 作者签名:日期:年月日 学位论文版权使用授权书 本学位论文作者完全了解学校有关保留、使用学位论文的规定,同意学校保留并向国家有关部门或机构送交论文的复印件和电子版,允许论文被查阅和借阅。本人授权大学可以将本学位论文的全部或部分内容编入有关数据库进行检索,可以采用影印、缩印或扫描等复制手段保存和汇编本学位论文。 涉密论文按学校规定处理。 作者签名:日期:年月日 导师签名:日期:年月日

某医院中央空调工程施工组织设计

xx医院中央空调工程 施工组织设计 编制: 审核: 批准: xxxx安装工程有限公司 二○○五年一月九日

第一章编制依据 1、国家标准及规范 a.GBJ302-88《建筑采暖卫生与煤气工程质量检验与评定标准》 b.GBJ242-88《通风与空调工程质量检验评定标准》 c.GBJ242-82《采暖与卫生工程施工及验收规范》 d.GB50243-2002《通风与空调工程施工质量验收规范》 2、本公司《施工组织设计编制规则》

第二章工程概况 一、工程概况: 1、本工程为xxxx中央空调工程,工程内容包括空调水系统、机房系统安装。 2、施工条件: 开工前已完成了施工现场的整理。同时施工机具需要量、材料设备需要量及进场计划,劳动力需要量计划均已编制完毕且准备就绪。施工实行现场管理,由施工负责人和技术负责人负责全面管理工程进度和质 量控制。 3、质量目标: 本工程安装完成交付使用时,质量达到下述目标: 1)合同范围内的全部工程的使用功能均符合设计要求。 2)分项工程质量达到建筑工程质量检验评定标准,合格率达到100%,工程竣工达到合同规定标准。 第三章工程质量标准 工程各分项工程施工质量均达优良标准,系统调试按设计要求一次成功。 第四章各分项工程的施工方案 一、空调水系统安装 (一)管道冷热(媒)水系统安装分项工程 1、材料要求 1)管材:无弯曲、锈蚀、无飞刺、重皮、凸凹不平现象。 2)管件:无偏扣、乱扣、断线和角度不准确现象。 3)阀门:铸造规矩,无毛刺、丝扣无损伤,直度和角度正确,

开关灵活严密。 4)管材、阀门必须具有合格证。 2、施工准备 1)竖管安装:位于管道井内,安装应配合土建施工。 2)干管安装必须在确定准确的楼地面标高后进行。 3)支管安装必须在墙面抹灰后进行。 3、施工工艺 1)工艺流程: 安装准备——预制加工——卡架安装——竖管安装——干管安装——支管安装——冲洗——试压——防腐——保温2)安装准备 a.认真熟悉图纸,安装预埋件。 b.按设计图纸画出管路的位臵、管径、变径、预留口坡向、卡回位臵等施工草图,包括干管起点,末端和转弯、节点、预留口、坐标位臵等。 3)坚管安装 按设计要求或规定间距,安装支架,竖管从下向上安装。 竖管的连接方式:采用焊接,接头形式应符合焊接工艺操作规程。 焊接设备:BX-300交流电焊机,按《作业指导书》规定进行焊接。焊工必须具有上岗证,无证人员不准焊接。 焊接的外观质量检查和验证标准见GBJ242-82《采暖与卫生工程施工及验收规范》第九章管道焊接第二节碳素钢管管道焊接表9.2.6.1、表9.2.12之规定。 4)干管安装

三层别墅中央空调工程设计

河南机电高等专科学校 毕业设计说明书 设计题目:三层别墅中央空调系统 系部 专业 班级 学生姓名 学号 指导教师 2012年12 月31 日

摘要 家用中央空调是指根据国家空调设计规范的设计参数和要求进行选型设计、安装的,用于家庭的空调系统。家用中央空调是由室外主机、室内风机盘管及其连接的风道送出冷热风以达到室内空气调节目的的空调系统,按工作原理可分为二种:一种是由大型中央空调系统的设备演化而来的空调系统如小型风冷冷水机组,小型风管机组为主机的产品;另一种是由分体壁挂空调设备演化而来的空调系统如一拖小型风管机组属集中中央空调系统,此系统由室外机组,室内风机盘管及盘管连接的送风管道组成。送风管道通向各个需要空气调节的房间,风道系统可安装流量调节阀、风口等配件,一台主机可控制多个不同房间并且可引入新风,有效改善室内空气品质。 步入21世纪,人们对生活品质要求不断提高,住宅面积不断地扩大,以窗机、分体挂壁机和柜机为代表的传统的家用空调已不能充分满足环境、能源的需要。目前家用空调市场上的产品,从严格意义上讲只能称为“温调”,真正的”空调”应具备空气质量调节的功能,不仅调节空气冷暖,而且可以通风换气,调节空气湿度、有机挥发物含量、细菌含量等室内空气的综合品质。从这个意义上,家用中央空调才把人们带入到“真正的空调时代”。这种集大型中央空调和家用空调优点于一体的小型化独立空调系统恰到好处地适应了目前市场的需求,代表了21世纪人居空调的发展趋势,更重要的是,它跨越了我国空调产业长期以来存在的“中央空调”与“家用空调”间的界限,开辟出了一个崭新的市场空间。 关键词:工作原理系统分类中央空调的现状前景家用中央空调的发展趋势

相关主题