当前位置:文档之家› 风机风量测试报告

风机风量测试报告

风机风量测试报告

University of Illinois Department of Agricultural and Biological Engineering

Bioenvironmental and Structural Systems Lab

Final Report

Project Number:13327

Test Date:July 16, 2013

Fan:Motor:Shutter:

Make-Munters Euroemme Make-Munters Material-galvanized steel

Model-EC52, 2HP Model-'043139# Doors-10

Blade dia.-52.5"Hp- 2 hp (1.5 kW)# Columns-1

Orifice dia.-53"RPM-1400 // 1680Door length52.6"

Volts-230 / 400Location-intake

Blade:Amps- 6.1/3.5 // 5.5/3.2

Number-4Hz-50 // 60Guards:

Shape-propeller Phase-3Description-wire

Material-stainless steel S. F.--Spacing-3"

Pitch--Location-exhaust

Clearance-0.3"Housing:

Material-galvanized steel Discharge Cone:

Drive Sheaves:Intake area-53" x 53.6"Depth-30.1"

Drive dia.- 4.4" (111mm) o.d.Discharge-53" dia.Minor dia.-53"

Axle dia.-13" o.d.Depth-17.7"Major dia.-64.4"

059" flat sides

Notes:* 50 Hz test, Centrifugal shutter opener

Test Conditions:

T(wb) F:66Barometric pressure, recorded29.67

T(db) F:78.5Barometric Pressure, corrected29.54(In. Hg)

SI Units

Static Static

Pressure Airflow Pressure Airflow

(in.H2O)(cfm)rpm Volts Amps Watts cfm/Watt(Pa)(m^3/hr.)(m^3/hr)/W W/1000m^3/hr

0.0029100461402.0 3.10151419.204950032.731

0.0527900460401.3 3.15156517.8124740030.333

0.1026300459400.9 3.19161516.3254470027.736

0.1524100457400.0 3.25165714.5374090024.741

0.2021400456399.4 3.28168712.7503640021.646

0.2519300455399.0 3.31171511.2623280019.152

0.3016600455398.6 3.3217279.6752820016.361

风机选型所需风量的设计计算方法

风机选型所需风量的设计计算方法应不同地区不同客户,制造厂有义务指导客户如何选择适当风量,兹将风量选择方法,介绍如下: 首先必须了解一些已知条件: 1.1卡等于1g重0℃的水使其温度上升1℃所需的热量。 2.1瓦特的功率工作1秒钟等于1焦尔。 3.1卡等于 4.2焦尔 4.空气的定压(10mmAq)比热(Cp)=0.24(Kcal/Kg℃) 5.标准状态空气:温度20℃、大气压760mmHg、湿度65%的潮湿空气为标准空气,此时单位体积空气的重量(又称比重量)为1200g/M*3 6.CMM、CFM都是指每分钟所排出空气体积,前者单位为立方米/每分;后者单位为立方英呎/每分钟。 1CMM=35.3CFM。 2,公式推算一、得知:风扇总排出热量(H)=比热(Cp)×重量(W)×容器允许温升(△Tc) 因为:重量W=(CMM/60)×D=单位之间(每秒)体积乘以密度 =(CMM/60)·1200g/M*3=(Q/60)×1200g/M*3所以:总热量 (H)=0.24(Q/60)·1200g/M*3·△Tc 二、电器热量(H)=(P[功率]t[秒])/4.2 三、由一、二得知: 0.24(Q/60)·1200g/M*3·△Tc=(P·t)/4.2Q=(P×60)/1200·4.2·0.24·△TcQ=0.05P/△Tc (CMM)=0.05·35.3P/△Tc=1.76P/△Tc…………………………(CFM) 四、换算华氏度数为:Q=0.05·1.8P/△Tf=0.09P/△Tf (CMM)=1.76·1.8P/△Tf=3.16P/△Tf…………………………(CFM)↑TOP3, 范例例一:有一电脑消耗功率150瓦,风扇消耗5瓦,当夏季气温最噶30℃,设CPU允许工作60℃,所需风扇风量计算如下:P=150W+5W=155W;△ Tc=60-30=30Q=0.05×155/30=0.258CMM=9.12CFM(为工作所需风量)所以,应选择实际风量为Qa之风扇

风机测试方案

通风机安全检测检验方案 山西公信安全技术有限公司 二〇一八年六月二十一日

通风机安全检测检验方案 为搞好通风管理、确保通风机装置安全、经济运行提供科学的依据,依据《煤矿在用主通风机系统安全检测检验规范》AQ1011-2005的规定要求,山西公信安全技术有限公司受炭窑坪煤业有限公司委托对该矿主通风机不同角度(+2.5,-2.5,0,+5,-5)进行安全检测检验。经现场查看和矿方对检测检验的要求,制订本方案。 一、确定通风网络的组成 本次通风机安全检测检验是在由防爆门、回风井、风硐、通风机、扩散器等部分组成可供调节的通风网络。 二、检测项目及测点布置 1.风压 利用风机现有静压测孔,接上矿井通风参数测定仪,直接测定各调节点的相对静压值。 位置:风机集流器处 形状:圆形 2.风量测定 在扩散器风流出口处安装智能测试风杯,测量风速。 3.电气参数 在主通风机电控柜的二次测线路中接入电动机经济运行测试仪,测取电动机的输入功率、电压、电流、功率因数等电气参数。 4.空气密度 用矿井通风参数仪测定风机房阴凉处的大气压力,用温湿度计在

风流出口处测取风流的温湿度,计算各调节工况点空气密度。 5.噪声 在距离通风机扩散器45°方向的3.4m处、离地高度1m处用声级计测取扩散器的A声级噪声。距通风机电机外壳1m外测量机壳辐射噪声。 6.转速 参照额定转速。 7.振动 用便携式测振仪在通风机直接与坚硬基础紧固连接处测量风机的振动。 8.轴承温度 利用矿方现有传感器直接读取数值。 9. 叶片径向间隙 用塞尺在主通风机叶片与机壳(或保护圈)的间隙处测量该间隙值。 三、测定条件 1.装置完好条件: ①测定前应检查通风机、电动机各零部件是否齐全,装配是否紧固,运行是否正常,备用风机确保在10分钟内启动,以保障在测定过程中通风机能安全运行。 ②通风机进风口或出风口至风量、风压测定断面之间应无明显漏风,以确保测定工作的准确性。

风机风量计算方法

风机风量计算方法 风机风量的定义为:风速V与风道截面积F的乘积.大型风机由于能够用风速计准确测出风速,所以风量计算也很简单,直接用公式Q=VF,便可算出风量. 风机数量的确定根据所选房间的换气次数,计算厂房所需总风量,进而计算得 风机数量。计算公式:N=V×n/Q 其中:N——风机数量(台); V——场地体积(m3); n——换气次数(次/时); Q——所选风机型号的单台风量(m3/h)。 风机型号的选择应该根据厂房实际情况,尽量选取与原窗口尺寸相匹配的风机型号,风机与湿帘尽量保持一定的距离(尽可能分别装在厂房的山墙两侧),实现良好的通风换气效果。排风侧尽量不靠近附近建筑物,以防影响附近住户。如从室内带出的空气中含有污染环境,可以在风口安装喷水装置,吸附近污染物集中回收,不污染环境 引风机所需风量风压如何计算 1、引风机选型,首要的是确定风量; 2、风量的确定要看你做什么用途,不同的用途风量确定方法不一样,请参照专业书籍或者请教专业技术人员; 3、确定了风量之后,逐段计算沿程阻力和局部阻力,将它们相加,乘以裕量系数,得出需要的压力; 4、查阅风机性能数据表,或者请风机厂家查找对应的风机型号即可 风机风量和风压计算功率,工业方面用,设计中,通过风量和风压计算风机的大概功率 功率(KW)=风量(m3/h)*风压(Pa)/(3600*风机效率*机械传动效率*1000)。风量=(功率*3600*风机效率*机械传动效率*1000)/风压。 风机效率可取0.719至0.8;机械传动效率对于三角带传动取0.95,对于联轴器传动取0.98。

风量如何计算?要加入风机功率管道等因素,抽风空间的大小等? 比如说:100平方的房间我需要每小时抽风500立方,要怎么求出它的风机的功率,管道等。还有风速和立方怎么算出来的,比如说0.1或0.5米每秒的风速多长时间可以抽100立方或500立方的风?以上的两个问题要求有个计算公 式,公式中的符号要注明。 一、 1、管道计算 首先确定管道的长度,假设管道直径。计算每米管道的沿程摩擦阻力: R=(λ/D)*(ν^2*γ/2)。 2、计算风机的压力:ρ=RL。 3、确定风量:500立方。 4、计算风机功率:P=500立方*ρ/(3600*风机效率*1000*传动效率)。 5、风量计算:Q=ν*r^2*3.14*3600。 6、风速计算:ν=Q/(r^2*3.14*3600) 7、管道直径计算:D=√(Q*4)/(3600*3.14*ν) 二、 1、风速为0.5m/s时,计算每小500立方米风需要多长时间。假设管道直径为0.3m。 Q=ν*r^2*3.14*3600 =0.5*(0.3/2)^2*3.14*3600 =127.2(立方) 500/127.2=3.9(小时) 建议:风速最好确定在12m/s比较合适,提高风速后可以缩小管道的直径。

轴流风机测试报告

SUNON轴流风机测试报告 编制:日期: 校核:日期: 审核:日期: 批准:日期:

目录 SUNON轴流风机测试报告 0 目录 (1) 1 测试的基本信息 (1) 1.1 样品型号、测试时间、测试人员,测试地点等情况 (1) 1.2 测试说明 (1) 1.3 测试仪器 (1) 2 测试内容 (2) 2.1 外观尺寸检查 (2) 2.1.1 结构尺寸检查 (2) 2.1.2 外观检查 (3) 2.2 功能测试 (3) 2.2.1 风机气流流向 (3) 2.2.2 风机运行稳定性测试 (4) 2.3 性能测试 (5) 2.3.1 最低启动电压测试 (5) 2.3.2 最大正常工作电压测试 (6) 2.3.3 工作电流值测试 (7) 2.3.4 功耗测试 (8) 2.3.5 噪音测试 (9) 2.3.6 风速测试 (10) 2.3.7 绝缘电阻测试 (11) 2.4 可靠性测试 (12) 2.4.1 高温测试 (12) 2.4.2 低温测试 (13) 3 结果汇总 (15) 3.1 测试项目汇总 (15) 4 参考文档 (15) 附录1 测试数据 (17) 附表A结构尺寸 (17) 附表B 外观检查 (17) 附表C 最低启动电压数据 (17) 附表D 电流数据 (17) 附表E 工作电压范围内功耗数据 (17) 附表F 噪音测试数据 (18) 附表G 风速测试数据 (18)

1测试的基本信息 1.1样品型号、测试时间、测试人员,测试地点等情况 样品型号DP201A 2123HBT.GN 样品名称轴流风机 生产批号F1803V 制造厂商建准电机工业股份有限公司 代理商 测试次数 1 测试人员 测试时间 1.2测试说明 本着适用的原则,结合轴流风机主要参数及我公司现有的测试条件,对1#,2#两台轴流风机进行的测试项目有: 一.外观尺寸检查 1.结构尺寸检查 2.外观检查 二.功能测试 1. 气流流向 2. 运行稳定性 三.性能测试 1.最启起动电压 2.最大正常工作电压 3.电流值 4.功耗 5.风速 6.噪音 7.绝缘电阻 四.可靠性测试 1. 高温 2. 低温 1.3测试仪器 测试所需仪器列举如下:

轴流式风机的性能测试及分析

轴流式风机的性能测试及分析 摘要 轴流式风机在火力发电厂及当今社会中得到了非常广泛的运用。本文介绍了轴流式风机的工作原理、叶轮理论、结构型式、性能参数、性能曲线的测量、运行工况的确定及调节方面的知识,并通过实验结果分析了轴流式风机工作的特点及调节方法。 关键词:轴流式风机、性能、工况调节、测试报告

目录 1绪论 1.1风机的概述 (4) 1.2风机的分类 (4) 1.3轴流式风机的工作原理 (4) 2轴流式风机的叶轮理论 2.1概述 (4) 2.2轴流式风机的叶轮理论 (4) 2.3 速度三角形 (5) 2.4能量方程式 (6) 3轴流式风机的构造 3.1轴流式风机的基本形式 (6) 3.2轴流式风机的构造 (7) 4轴流式风机的性能曲线 4.1风机的性能能参数 (8) 4.2性能曲线 (10) 5轴流式风机的运行工况及调节 5.1轴流式风机的运行工况及确定 (11) 5.2轴流式风机的非稳定运行工况 (11) 5.2.1叶栅的旋转脱流 (12) 5.2.2风机的喘振 (12) 5.2.3风机并联工作的“抢风”现象 (13) 5.3轴流式风机的运行工况调节 (14) 5.3.1风机入口节流调节 (14) 5.3.2风机出口节流调节 (14) 5.3.3入口静叶调节 (14) 5.3.4动叶调节 (15) 5.3.5变速调节 (15) 6轴流风机性能测试实验报告 6.1实验目的 (15) 6.2实验装置与实验原理 (15) 6.2.1用比托静压管测定质量流量 6.2.2风机进口压力 6.2.3风机出口压力

6.2.4风机压力 6.2.5容积流量计算 6.2.6风机空气功率的计算 6.2.7风机效率的计算 6.3数据处理 (19) 7实验分析 (27) 总结 (28) 致谢词 (29) 参考文献 (30)

风速风量计算方法

风量(Q):所谓风量(又称体积流率)指的是风管之截面积所通过气流之流速,一般在使用上以下式来表示: Q=60VA Q(风量)=m3/min V(风速)=m/sec A(截面积)=m2 压力常用换算公式 1Pa=0.102mmAq 1mbar=10.197mmAq 1mmHg=13.6mmAq 1psi=703mmAq 1Torr=133.3pa 1Torr=1.333mbar 常用单位换算表-风量 1m3/min(CMM)=1000 l/min = 35.31 ft3/min(CFM) 常用名词说明(1)标准状态:为20℃,绝对压力760mmHg,相对湿度 65%。此状态简称为STP,一般在此状态下1m3之空气重量为1.2kg。 (2)空气之绝对压力:为当地大气压计所显示的大气压力再加上表压力之和,一般用kgf/m2或mmaq来表示。 (3)基准状态:为0℃,绝对压力760mmHg,相对湿度0%。此状态简称为NTP,一般在此状态下1m3之空气重量为1.293kg。 压力(1)静压(Ps):所谓静压就是流体施加於器具表面且与表面垂直的力,在风机中一般是由於重力与风扇之推动所造成,在使用上常以kgf/m2或mmaq来表示,且可以直接经过量测取得。而在风机之风管中,任何方向之静压值皆为定值且也有正负之分,若静压值为正则表示风管目前正被胀大,若静压值为负则表示风管目前正受挤压。 (2)动压(Pv):所谓动压就是流体在风管内流动之速度所形成之压力,在使用上常以kgf/m2或mmaq来表示. (3)全压(PT):所谓全压就是静压与动压之和,在使用上常以kgf/m2或mmaq来表示。在风机中全压值是属固定,并不会因风管缩管而产

风机性能试验

风机性能试验 一、测量参数及测点布置 1、风机静压测量:(测点位置参考西安院在成都轴流风机所做试验报告) 引、送风机的进口静压测点均布置于各风机进风箱进口法兰略上的矩形直管段上,每个侧壁面中心线处各设一个静压测点,每台风机共设置4个进口静压测点。 引、送风机的出口静压测点布置于各风机扩压筒出口法兰略前的圆形管段上,每台风机沿圆周方向均匀布置3个静压测点。 一次风机进口静压测点布置于进口风门下部, 每个侧壁面中心线处各设一个静压测点,共设置4个进口静压测点。出口静压测点可利用现有标定孔测量。 附图1 1、1压力测孔内径d=2~3mm,最大不超过5mm,外部短导管内径为2~2.5d。见附图1。 1、2介质温度测点采用流量测量截面的测点。 2、流量测量 2、1测量截面布置:(测点位置参考西安院在成都轴流风机所做试验报告) 引风机的流量测量截面布置于引风机进气箱略前的收敛管段上,每台风机设置10个流量测孔。 送风机的流量测量截面布置于送风机进气箱略前的收敛管段上,每台风机设置8个流量测孔。我厂靠背管加长杆接头外径为32 φmm,引风机处测孔孔径应取不小于50 φmm。管座加工见附图。

一次风机流量测量可利用现有标定孔测量 附图2:点1和点2处分别为风机入口平面与出口平面。 2、2流量测量项目及公式 2、2、1风机流量ρ νd A p 2q ? = q V =为测量截面处流量,m 3/s ,A=截面面积m 2,ρ=流量测量截面处介质密度kg/m 3, P d =流量测量截面处平均动压,Pa 。 或风机流量q V =A ×ν q V =测量截面处流量m 3/s ,ν=测量截面处气流平均速度,m 3/s ,A=测量截面面积m 2 式中101325 273273 293.1s a p p t +?+? =ρ Pa=当地大气压Pa ,Ps=测量截面处静压Pa ,t 为流量测量截面处介质温度℃。 2、2、2风机全压()??? ? ? ?-+-=222 1122212νρνρs s p p P 式中P =风机全压Pa ,1s p =点1处静压Pa ,2s p =点2处静压Pa ,1ν=点1处气流速度,点2处气流速度2ν= 2 2ρA q m m/s 。m q =1A 1d 2ρP kg/s 2、2、3风机功率K/1000P ×q ?=νt P KW K=气体可压缩系数约为0.96,P =风机全压Pa,νq =风机容积流量m 3/s 2、2、4风机轴功率tr P P η0a = a P =风机轴功率,mot UI P ?ηcos 30=,tr η=传输效率%,直连时tr η=1。 0P =电动机输出功率,?cos =电动机功率因数,mot η=电动机效率。

风量风压风速的计算方法

离心式风机风量风压转速的关系和计算 n:转速 N:功率 P:压力 Q:流量 Q1/Q2=n1/n2 P1/P2=(n1/n2)平方 N1/N2=(n1/n2)立方 风机风量及全压计算方法风机 功率(W)=风量(L/S)*风压(Kpa)/效率(75%)/力率(75%) 全压=静压+动压。风机马达功率(W)=风机功率(W)*130%= 风量(L/S)*风压(Kpa)/效率(75%)/力率(75%)*130% 风机的,静压,动压,全压 所谓静压的定义是:气体对平行于气流的物体表面作用的压力。通俗的讲:静压是指克服管道阻力的压力。 动压的定义是:把气体流动中所需动能转化成压的的形式。通俗的讲:动压 是带动气体向前运动的压力。 全压=静压+动压 全压是出口全压和入口全压的差值 静压是风机的全压减取风机出口处的动压(沿程阻力) 动压是空气流动时自身产生的阻力P动=*密度*风速平方 P=P动+P静 、两台型号相同且转速相等的风机并联后,风量最高时是两台风机风量的90%左右,风压等于单台风机的压力。 2、两台型号相同且转速相等的风机串联后,风压是单台风机风压的2倍,风量等于单台风机的风量。 3、两台型号不同且转速不等并联使用,风量等于较大的一台风机的风量,风压不叠加。 4、两台型号不同且转速不等,型号较大的一台置前串联使用,风压小于单台风机的风压,风量等于较大的一台风机的风量 风速与风压的关系 我们知道,风压就是垂直于气流方向的平面所受到的风的压力。根据伯努利方程得出的风-

压关系,风的动压为 wp=·ro·v2 (1) 其中wp为风压[kN/m2],ro为空气密度[kg/m3],v为风速[m/s]。 由于空气密度(ro)和重度(r)的关系为r=ro·g, 因此有 ro=r/g。在(1)中使用这一关系,得到 wp=·r·v2/g (2) 此式为标准风压公式。在标准状态下(气压为1013 hPa, 温度为15°C), 空气重度 r= [kN/m3]。纬度为45°处的重力加速度g=[m/s2], 我们得到

风机安全系统和功能测试报告 -Southwest Windpower H40

Wind Turbine Generator System Safety and Function Test Report for the Southwest Windpower H40 Wind Turbine J. van Dam, H. Link, M. Meadors and J. Bianchi National Renewable Energy Laboratory 1617 Cole Boulevard

National Renewable Energy Laboratory 1617 Cole Boulevard Wind Turbine Generator System Safety and Function Test Report for the Southwest Windpower H40 Wind Turbine J. van Dam, H. Link, M. Meadors and J. Bianchi Prepared under Task No. WER2 3215

NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof. Available electronically at https://www.doczj.com/doc/7517225194.html,/bridge Available for a processing fee to U.S. Department of Energy and its contractors, in paper, from: U.S. Department of Energy Office of Scientific and Technical Information P.O. Box 62 Oak Ridge, TN 37831-0062 phone: 865.576.8401 fax: 865.576.5728 email: reports@https://www.doczj.com/doc/7517225194.html, Available for sale to the public, in paper, from: U.S. Department of Commerce National Technical Information Service 5285 Port Royal Road Springfield, VA 22161 phone: 800.553.6847 fax: 703.605.6900 email: orders@https://www.doczj.com/doc/7517225194.html, online ordering: https://www.doczj.com/doc/7517225194.html,/ordering.htm

风机技术要求

中央排风机技术要求 1.1 总则 1.1.1 说明 本章说明有关各类型风机的制造、安装及调试所需的各项技术要求。 1.1.2 一般要求 (1) 须按照设备表内所标注的送风量、数量、用电量及风机类型选取且提供合适的风机。任何对系统因须满足所列的功能和空间而引起的须对部份设备(如风机、电动机、控制组件、电缆等)作修改或更换以匹配时, 费用一概由分包商负责, 除非修改是由更改指示所致。(2) 有关设备,无论在运送、储存及安装期间应采取正确的保护设施,以确保设备在任何情况下不受破损。 (3) 如无特别标明,所有风机的出风口风速不能超过10 米/秒以减低噪音产生。 1.1.3 质量保证 (1)厂家需具有五年以上生产同类型的风机的经验,而且有关风机须符合有关技术要求。 (2) 所有风机的驱动型式及配件,应按照美国AMCA 或其它国际认可机构/组织所制定的标准要求进行设计及试验。 (3) 风机应按照美国AMCA 标准第210 的最新版本的要求或其它国际认可机构组织所制定的标准进行测试。 (4) 风机运行时所产生噪音应达到美国AMCA 标准或其它国际认可机构/组织所制定有关送风设备噪音调试的要求和不超过环保局所订定的标准。 (5) 每台风机须附有详细标明厂家的名称、设备的型号和编号及有关的技术数据等资料的标志名牌。 (6) 系统设计、系统之各项指标、系统设备、材料及工艺均须符合我司所提供的规范/标准。 1.1.4 资料呈审 (1) 提交由原厂所编印的风机特性曲线,显示有关风机的总负荷功能,空气流量与压头,风机功率,噪音水平等技术资料。 (2) 提供完整的设备配件表及原厂建议的后备配件表。 (3) 提供有关风机于工地所进行的试验报告,内容须包括试验时所得的数据和结果。 (4) 提供每一风机在指定的工作条件下所产生由63HZ 到8000HZ 频带的噪音数据。 (5) 提交由原厂编印的安装、操作及维修手册。 (6) 提交安装大样图包括风管接驳,避震弹簧,吊架及其它土建要求。 1.2 产品 1.2.1 概述 (1) 风机应在其整个操作范围内具有无超负荷的特性。 (2) 大型离心式及轴流式风机须设有吊眼以协助安装。 (3) 风机须在静态及动态进行平衡调试。 (4) 所有离心式风机的驱动轴末端须预留测试孔以便转速测试。 (5) 如无特别标明,电动机转速不可超过1450 转/分钟。 (6) 所有风机及其电动机于正常操作情况下,不能产生太大的震动和噪音。如发觉所产生的震动和噪音超越可接受的程度时,须提供足够的防震和消音措施。 1.2.2 离心式风机/箱式离心风机 (1) 按图纸/设备表所标注提供前弯/后倾叶片式离心风机。 (2) 除特别标明外,如风机工作功率超过7.5kW,则须采用后倾叶片风机,其效率不应低于75%。 (3) 风机外壳:

离心风机检测标准

离心风机检测标准 文稿归稿存档编号:[KKUY-KKIO69-OTM243-OLUI129-G00I-FDQS58-

离心式通用风机 1.通则 1.1本章概要 本章节说明离心式风机的制造、工厂测试、交货及安装时之要求。 1.2 工作范围 1.2.1 离心式风机。 1.2.2 设备的安装、操作及维修之设备。 1.3相关章节 1.3.1第15950章--测试、调节及平衡。 1.3.2第15820章--风管附属设备。 1.4国家标准或国际标准 1.4.1 风机测试标准:风机的空气性能或噪音参数,须依以下之一种标准测试(1)中国国家标准(CNS) -CNS7778B4046送风机 -CNS7779B7165送风机检验法 (2)空气运动及控制协会(AMCA) -AMCA210 -AMCA300 - AMCA301 (3)英国国家标准(BS) -BS848PART1 -BS848PART2 (4)国际标准组织(ISO) - ISO5801 1.4.2承包商可建议采用其他国际法规或标准,但须经工程司(技师)核可同意 后使用。 1.5制造商及产品质量的要求 1.5.1提供风机之制造商,应为台湾区冷冻空调工程工业同业公会之会员,至 少须有5年的制造经验。 1.5.2性能认证︰安装功率在1.5kW(含)以上的离心风机,须依照AMCA211取 得空气性能的认证,产品须贴附AMCA性能认证标签。若未 取得AMCA空气性能认证之产品,则须经工研院能资所热流 与送风实验室,或经TAF认证之第3独立公正实验室并经 第3公证人认证下,依AMCA210进行测试,并检附空气性 能正本测试报告(每个风机机型,一份测试报告)。若风量 或静压大于工研院之实验室设备之规格而无法进行时,则 可由制造厂商于工厂进行测试,但制造厂商应于送审时提 送出厂的性能测试程序,以供审查。

风量风压计算公式

风量风压计算公式 该帖被浏览了2690次 | 回复了4次 风量风压计算公式 风量计算 风量(Q):所谓风量(又称体积流率)指的是风管之截面积所通过气流之流速,一般在使用上以下式来表示: Q=60VA Q(风量)=m3/min V(风速)=m/sec A(截面积)=m2 压力常用换算公式 1Pa=0.102mmAq 1mbar=10.197mmAq 1mmHg=13.6mmAq 1psi=703mmAq 1Torr=133.3pa 1Torr=1.333mbar 常用单位换算表-风量 1m3/min(CMM)=1000 l/min = 35.31 ft3/min(CFM) 常用名词说明 (1)标准状态:为20℃,绝对压力760mmHg,相对湿度65%。此状态简称为STP,一般在此状态下1m3之空气重量为1.2kg。 (2)空气之绝对压力:为当地大气压计所显示的大气压力再加上表压力之和,一般用kgf/m2或mmaq来表示。 (3)基准状态:为0℃,绝对压力760mmHg,相对湿度0%。此状态简称为NTP,一般在此状态下1m3之空气重量为1.293kg。 压力

(1)静压(Ps):所谓静压就是流体施加於器具表面且与表面垂直的力,在风机中一般是由於重力与风扇之推动所造成,在使用上常以 kgf/m2或mmaq来表示,且可以直接经过量测取得。而在风机之风管中,任何方向之静压值皆为定值且也有正负之分,若静压值为正则表示风管目前正被胀大,若静压值为负则表示风管目前正受挤压。 (2)动压(Pv):所谓动压就是流体在风管内流动之速度所形成之压力,在使用上常以kgf/m2或mmaq来表示. (3)全压(PT):所谓全压就是静压与动压之和,在使用上常以kgf/m2或mmaq来表示。在风机中全压值是属固定,并不会因风管缩管而产生变化. 风压与温度 温度变化会影响空气之密度。故在其他条件不变的情况下,温度变化时,其风压必须依下面之关系加以校正,以获得标准情况下之风压值: P = P’[(273 + t)/293] (mm Aq) 同样,当空气密度变更时,其风压值可作如下之修正: P = P’(1.2/γ ) (mm Aq) 式中,等号右侧之值如P’、t、γ等之实测压力、温度与空气密度。 压力与速度的关系 多大的压力就固定有多大的速度,不可能压力不变速度会改变,同理,不可能 有关风机风量的计算公式

轴流主通风机性能测试报告

轴流主通风机性能测试报告

煤矿主要通风机性能测定报告 报告编号:2010—01 受测单位:犍为县板板桥煤矿 产品名称:矿用主要通风机 产品型号:FBCDZ—6—№14 测定类别: 日期:2010年10月23日

一、煤矿用主要通风机现场测定基本情况 1、测定的技术依据:煤矿用主要通风机现场性能参数测定方法(MT 421—1996) 2、测定时间:2010年10月23日 3、测定条件和要求; 1)测定前检查通风机、电动机各零部件齐全,装配紧固,运行正常。 2)风井口风门无明显漏风。 3)引风道、风硐内无杂物堆积和积水。 4)利用通风机自身的闸门进行风量调节。 5)每调节一次风量、风压为通风机的一个工况点,通风机的特性曲线应包含有7个以上工况点。 6)风量调节闸门,应安装牢固,其强度应能承受大于通风机最大风压1.5倍的压力。位置应设在距通风机入口大于5倍叶轮直径的巷道内。 4、测定方案: 1)空气密度测定 在风井测风站内的巷道中,用气压计测量绝对静压,用干、湿温度计测量干、湿温度。每调节工况1次测量3次,取其算术平均值计算空气密度。 2)风量测定 利用监控系统风速传感器监测、计算巷道风量,每调节工况1次记录3次,取其算术平均值计算巷道风量。 3)风压测定 a.测压断面选定在风井内与风量测定同一位置。

b.在风井断面上均匀布置4~5根皮托管。用干净、畅通、不漏气的软管,将皮托管的“—”接头与压差计连接,测量静压;将皮托管的“+”接头与压差计连接,测量全压;将皮托管的“+”、“—”接头同时与压差计两端连接,测量速压。 4)转速测定 用转速表测量电动机(风机)转速,每调一个工况点测3次,取其算术平均值。 5)通风机功率测定 用电流表、电压表、功率因数表分别测定电动机电流、电压、功率因数。 6)噪声测量 在主要通风机扩散器出口外,测量风机噪声。 7)反风风量测量 改变风机(电机)运转方向后,利用监控系统风速传感器监测、计算巷道风量。 二、测量仪器 序号仪器名称型号 数 量 只 (台) 检定 有效 期 用途 1 气压计 800~ 1060 hPa 1 有效 测大气 压力 2 温度计0~50℃ 1 有效测温度 3 皮托管 5 有效测压力

通风能力核定报告

通风能力核定报告公司内部档案编码:[OPPTR-OPPT28-OPPTL98-OPPNN08]

山西介休大佛寺煤业有限公司 通风系统能力核定报告 一、核定通风系统生产能力的必备条件 矿井通风系统生产能力核定必备条件见表1。 表1 矿井通风系统生产能力核定必备条件 由上表可知,矿井具备通风系统生产能力核定的必备条件,可对矿井进行通风系统生产能力核定。 二、通风概况 矿井有完整独立的通风、防尘、防灭火及安全监控系统,通风系统合理,通风设施齐全可靠;采用机械通风,运转风机和备用风机具备同等能力,通风机经具备资质的检测检验机构测试合格;安全检测仪器、仪表齐全可靠;局部通风采用双风机,双电源,并能自动切换,局部通风机的安装和使用符合规定;井下不存在串联

通风;矿井瓦斯管理符合规程规定。通风系统具备能力核定必备条件。 ㈠、通风方式、方法 矿井通风方式采用分列式,主要通风机工作方式采用抽出式。 ㈡、进、回风井筒数量及风量 主、副斜井进风,回风立井回风。总进风量为6350m3/min,其中,主斜井进风2048m3/min,副斜井进风4302m3/min,总回风量6455m3/min。 ㈢、矿井需要风量、实际风量、有效风量 矿井需风量6280m3/min,实际风量6350m3/min,有效风量6300m3/min,有效风量率99%。 ㈣、矿井瓦斯等级 矿井2011年联合试运转期间的瓦斯等级鉴定结果批复为矿井瓦斯绝对涌出量1.98m3/min,瓦斯相对涌出量1.10m3/t,二氧化碳绝对涌出量3.17m3/min,二氧化碳相对涌出量1.67m3/t,属低瓦斯矿井。2012年生产期间瓦斯等级和二氧化碳涌出量鉴定结果为矿井瓦斯绝对涌出量3.28m3/min,相对涌出量1.91m3/t,二氧化碳绝对涌出量4.15m3/min,相对涌出量2.42m3/t,鉴定为低瓦斯矿井,故此次通风能力核定报告按2012年瓦斯等级及二氧化碳涌出量计算。 ㈤、主通风设备及运行参数 主通风机为两台FBCDZ-№25型对旋式轴流风机,一台工作,一台备用。配备电机型号为YBFH450M1-8,功率为2×280kW。据山西公信安全技术有限公司2012年2月提供的通风机技术性能测试报告,1#通风机:风量112.81m3/s,静压1810.1Pa,静压效率54.2%,2#通风机:风量111.85m3/s,静压1791.9Pa,静压效率53.2%,1、2#通风机检测项目符合AQ1011-2005标准要求,满足核定条件。 二、计算过程及结果

风量风压的计算方法

风量的计算方法,风压和风速的关系 1、假设在直径300mm的风管中风速为0.5m/m,它的风压是多少帕?怎么计算?(要求有公式,并说明公式中符号的意思,举例) 2、假如一台风机它的风量为100003/h,分别给10个房间抽风,就是有10个抽风口,风管的主管道是直径400mm,靠近风机的第一个抽风口的风压和抽风量肯定大于后面的抽风口,要怎么样配管才能使所有的抽风口的抽风量一样?要怎么计算? 3、如何快速的根据电机的转速、风机叶片的角度、面积来来计算出这台风机的风量和风压。?(要求有公式,并说明公式中符号的意思,举例) 4、风管的阻力怎么计算,矩形和圆形,每米的阻力是多少帕,一台风压为200帕的抽风机,管道50m,它的进风口的风压是多少帕??(要求有公式,并说明公式中符号的意思,举例) 首先,我们要知道风机压力是做什么用的,通俗的讲:风机压力是保证流量的一种手段。基于上述定义,我们可以通过一些公式来计算出在300mm管道中要保证风速为0.5m/s时所需的压力。 1.1、计算压力: 1.2、Re=(D*ν/0.0000151) =(0.3*0.5/0.0000151) =9933.77 1.3、λ=0.35/Re^0.25 =0.35/9933.77^0.25 =0.035 1.4、R=[(λ/D)*(ν^2*γ/2)]*65 =(0.035/0.3)*(0.5^2*1.2/2) =0.07Pa 1.5、结论:在每米直径300mm风管中要保证0.5m/s的风速压力应为0.07Pa。 2、计算400mm管道中的流速: 2.1、ν=Q/(r^2* 3.14*3600) =10000/(0.2^2*3.14*3600) =22.11(m/s) 2.2、平衡各抽风口的压力,并计算出各个抽风口的直径: 为保证各抽风口的流量相等,需对各抽风口的压力进行平衡,我们采用试算法调管径。当支管与主环路阻力不平衡时,可重新选择支管的管径和流速,重新计算阻力直至平衡为止。这种方法是可行的,但只有试算多次才能找到符合节点压力平衡要求的管径。 设1-2段的阻力值为Ho,为使节点2的压力达到平衡,应使4-2段的阻力H等于Ho。设每一个抽风口的间距为1m,每条支管长为1m(如图):

离心风机风量之现场测量

离心风机风量之现场测量

————————————————————————————————作者:————————————————————————————————日期:

离心风机风量之现场测量 新型干法水泥生产线中,生料的悬浮、分解、煤炭燃烧、熟料的冷却全部与风机运行相关。 进入分解炉与窑的空气量只能通过两者的阻力大小来调节。窑内阻力的变化导致进入分解炉三次风量的变化,导致煤的用量与助燃空气量的比例常处于非最佳状态中。 高温风机风量很难精确 悬浮预热器为保证生料在管道中的正常分散、换热需要各部分需要达到一定的风速。 当投料量变化时,相应的风量应该相应变化。但实际生产过程中,中控室控制画面上能看到的参数只是高温风机电机的电流、转速以及各级筒出口的压力与温度。用风是否合适,很难说清。 篦式冷却机用风量未知数 同样的原因中控室只能读出每台风机的压力、风机电机的电流、阀门开度或者风机转速。风量不同,二、三次风温度也不同,对燃料的燃烧影响很大。 一次风风量不精确 由于窑内火焰形状需要经常调节。一般仅仅知道内风、外风的压力,且常常没有进中控室显示。煤风的风量就更没有风量数据了。 某水泥厂三条带余热发电锅炉的新型干法水泥生产线。其中两条线余热发电量偏低。由于三条线所配主机设备完全一致,仅仅篦冷机风机型号略有不同。遂怀疑余热发电抽取热风热量不足,笔者对几台风机风量进行了测试,却发现从风机出口现场测定,完全测不准。 一.毕托管动压断面平均风速 目前对风机流量标定常用的方法是动压法,即利用毕托管测量出气管段截面的平均动压,再通过该计算公式得出风机的流量: Q=A×3600 ,其中ρ=1.293×(P0+Pa)×273/[(273+t) ×101325],A为风机出气管段所测截面面积m2,P为毕托管感测动压pa,ρ为出风口空气的密度Kg/ m3, P0为当地大气压,Pa为静压,t为气温。 各风机出风口段呈现以下几种情况: 1、渐扩管,且变化幅度较大; 2、弯管及多管交汇; 3、出风管较短,测量点只能选在离风机出风口较近的直管段; 4、仅少数风机有较长直管段,但较高,测量时不方便且不安全;

风机的重要参数及含义

风量风压计算公式 风机有2个很重要的参数,流量和升压,升压即风压。相对于一台风机来说,流量大,升压就降低,风压高,流量就减少 压头通常指全压,风量与全压存在以下关系,当风机尺寸已定,风量越大,全压越大, 风机流量是指就是指风机每分钟送风的立方米数。 风机流量=进口风量=出口风量。 “风量”与“风压”是风机的两个独立的、最主要的参数。 出口压力是风机的另一个重要参数。 同风压的两个风机可能风量不同,风量大的外形大,配电机大; 同风量的两个风机可能风压不同,风压大的叶轮直径大或叶轮转速高,配电机大。 对于给定的风机,尺寸参数都确定了,提高了转速会同时加大风量和提高风压 A——截面积 D——风量 dP——风压

空气密度——1.293×293/(273+风温) D=A×sqrt(dP/空气密度) sqrt.....开平方 风机流量就是单位时间内输送气体的多少,通常用体积流量来表示,也就是,每小时输送的立方米数。对于一般风机来说,风机输出的风速是小于100m/s的,此时,空气可以看做是不可压缩流体,于是,风机流量与进口风量和出口风量是相同的,因为,风机并不消耗空气,从进口来的空气全部从出口排出了。 如果风机的风速比较大,空气的压缩不能忽略,则进口风量和出口风量用体积流量来计算的话,会有差别,但是,它们的质量流量仍然是相同的,也就是每小时流过的空气的质量不变。此外,体积流量还会受到空气密度的影响,而空气密度与其工作的温度、大气压和湿度等环境因素都有关系。所以,在工程上,风机所标识的流量,都是换算到标准进口状态下进口处的体积流量。所谓标准进口状态,是指温度293K、气压101325Pa、相对湿度50%的空气状态。 常见的离心风机和轴流风机的流量都与风机压力有关,它在不同压力下的流量需要去查看风机性能曲线。而容积式风机(比如罗茨风机)的流量则与压力无关。

风机测试报告

文件名 : D:\试验数据\2013年风量试验数据\X13037\ZFF-7F-C 1#.FPT 日期 : 2013-1-21 13:38:21 测试者 : 汽车型号 : 空调型号 : 风机类型 : 产品型号 : 产品编号 : 风机直径 : mm 风轮宽度 : mm 出风口面积 : mm2 制造商 : =====================================================================================================================================================================序号时间大气压力温度湿度转速直流电压直流电流静压喷嘴压差空气密度实际风量标准风量功率效率hh:mm:ss mbar℃%rpm Volt A Pa Pa Kg/m^3m^3/h m^3/h watts% --------------------------------------------------------------------------------------------113:44:051022.713.646.9439524.0712.60.0190.8 1.2393872.87900.78304.00.0 213:46:131022.714.443.8449324.0711.8100.2299.6 1.2371799.53822.82284.38.1 313:50:261022.714.543.9465524.0610.9199.8370.0 1.2379720.85741.62263.015.7 413:52:191022.713.945.5479124.0610.0300.0508.9 1.2415636.18655.73239.622.8 513:54:551022.813.845.7496724.068.6400.8399.0 1.2433519.71535.92206.029.0 613:58:411022.713.845.4520524.06 6.7499.81020.6 1.2442350.36361.20161.231.1 =====================================================================================================================================================================