当前位置:文档之家› 艾得森变频器EV510变频器说明书

艾得森变频器EV510变频器说明书

艾得森变频器EV510变频器说明书
艾得森变频器EV510变频器说明书

目录

一、概述

1.1 产权说明····································································

1.2 铭牌说明···································································

1.3 型号说明································································

1.4 选型说明································································

1.5 开箱说明···································································

1.6 功率分布表····································································

1.7 制动单元和制动电阻选择································

二、安装和接线

2.1 基准型机箱尺寸······························································

2.2 基准型机箱安装要求····································································2.3 接线要求····································································

2.4 接线说明····································································

三、操作面板及安全事项

3.1 面板尺寸示意图····························································

3.2 面板按键说明···························································

3.3 面板指示灯说明····························································

3.4 参数修改方法····························································

3.5 安全注意事项····································································

四、功能参数一览表····················································

五、功能详细介绍································································

六、变频器RS485通讯协议

6.1RTU方式模式(Remote Termonal Unit)模式···························

6.2ASCII方式模式································································

七、故障咨询及对策

7.1 故障类型及处理办法··························································

7.2 其它故障案列分析··························································

八、标准规范

8.1 规格型号····································································

8.2 公共特性····································································

8.3 显示········································································

九、选件

9.1 选件表······································································

9.2 周边选件与变频器的连接图····················································

9.3 外引线连接示意图··························································

十、变频器的维护

10.1 日常检查····································································

10.2 定期检查····································································

10.3 除尘········································································

1

10.4 零部件的更换································································

十一、品质承诺

11.1 保修范围···································································11.2 三包规定····································································11.3 维权规定········································································

2

3

第一章 概 述

1.1产权说明

本公司生产的系列变频器已申请有以下专利,未经本公司授权请请勿侵权,否则将予以法律追究。 1) 磁通恒定装置软件设计 ZL 201220003175.4 2) IGBT 驱动电路设计 ZL 201220003151.9 3) 主控板与操作面板硬连接支架结构设计 ZL 201120526661.X 4) 多用途端子排列结构设计 ZL 201220104920.4 5) 大功率散热风扇量化结构设计 ZL 201120526278.4 6) 铁壳机箱抗干扰用材设计 ZL 201120526321.7 7) 机箱高效散热进风模式设计 ZL 201120531596.X 8) 塑壳机箱上盖人性化装卸结构设计 ZL 201120526628.7 9) 操作面板装饰框结构设计 ZL 201120526332.5 10)塑壳机箱外观形象设计 ZL 201130474756.7 11)面板装饰框外观形象设计 ZL 201130475361.9

1.2铭牌说明

1.3型号说明

1.4选型说明

1.负载等级: B为标准转矩负载型,125%额定电流以下长时间运行,200%瞬停。F为风机、水泵轻转矩负载型,115%额定电流以下长时间运行,160%瞬停。

2.需防水、防尘、防酸的场合请选择IP54防护等级,负载等级选择情况同上。

3.减速停车有惯性或停车减速运行中电机会反送电至变频器的场合应用,各型号变频器尾缀有带Z,另外加放电电阻,尾缀无带Z的需加制动单元箱。

4.由于电机拖动各种机械设备的负载特性不同,为使用户更加合理、方便的使用变频器,最大可能的避免用户由于选型错误或变频器参数误调造成浪费和损坏变频器,请用户注意针对以下不同机械设备有针对性的选用。

T普通调速型。(如风机、吹膜机、制袋机等)

R力矩收放卷专用型。(用于替代力矩电机收放卷)

Q快速启停专用型。(打桩机、冲击机、高位刹车型机等)

O高速刻痕机专用型。(安瓶机刻痕电机、雕刻机、轴承制造机械等)

Y永磁同步电机专用型。

H恒压控制专用型。

L离心风机专用型。

D电动汽车专用型。

F纺织机专用型。

1.5开箱说明

本变频器在出厂前经过了严格的质量检验和各项功能测试,并做防振动和防撞击等包装处理,但在运输途中有可能发生意外,致使产品受损。因此,在您收到产品后,请开箱检查。若以下所列出的任何一项有误,请及时与经销商或本公司联系。

1)检查变频器在运输途中是否造成损坏或螺丝松动;

2)箱内变频器一台附使用说明书一本(内附保修单一份)、合格证一张;

3)检查变频器的铭牌是否与您所订购产品一致;

4)检查有无异物在变频器内。

1.6功率分布表

机箱号输入电

压(V)

变频器型号

额定电流

(A)

适配电机

(KW)

马力

(HP)

0号单相

220

T22B0007/F0015- XXZ21

2.5/

3.5 0.75/1.5 1/2

T22B0015- XXZ21

T22B0015/F0022- XXZ21

6.5/9.5 1.5/2.2 2/3

T22B0022- XXZ21

T22B0022/F0037- XXZ21 9.5/13 2.2/3.0 3/5

4

1号T22B0037- XXZ21

T22B0037/F0055- XXZ21 13/17 3.0/5.5 5/7.5

0号

三相

380T33B0007/F0015- XXZ21

2.5/

3.5 0.75/1.5 1/2 T33B0015- XXZ21

T33B0015/F0022- XXZ21

3.5/5.0 1.5/2.2 2/3 T33B0022- XXZ21

T33B0022/F0030- XXZ21

5.0/7.0 2.2/3.0 3/4 T33B0030- XXZ21

T33B0030/F0037- XXZ21

7/8.5 3.0/3.7 4/5

1号T33B0037- XXZ21

T33B0037/F0040- XXZ21

8.5/10 3.7/4.0 4/5.5 T33B0040- XXZ21

T33B0040/F0055- XXZ21

10/13 4.0/5.5 5.5/7.5 T33B0055- XXZ21

T33B0055/F0075- XXZ21

13/17 5.5/7.5 7.5/10 T33B0075- XXZ21

2号T33B0075/F0110- XXZ21

17/23 7.5/11 10/15 T33B0110- XXZ21

T33B0110/F0150- XXZ21

23/31 11/15 15/20 T33B0150- XXZ21

3号T33B0150/F0185- XXZ21

31/37 15/18.5 20/25 T33B0185- XXZ21

T33B0185/F0220- XXZ21

37/44 18.5/22 25/30 T33B0220- XXZ21

4号T33B0220/F0300-XX21

44/60 22/30 30/40 T33B0300-XX21

T33B0300/F0370-XX21

60/74 30/37 40/50 T33B0370-XX21

5号T33B0370/F0450-XX21

74/90 37/45 50/60 T33B0450-XX21

T33B0450/F0550-XX21

90/110 45/55 60/75 T33B0550-XX21

T33B0550/F0750-XX21 110/150 55/75 75/100

5

T33B0750-XX21

6号

三相

380T33B0750/F0930-XX21

150/176 75/93 100/120 T33B0930-XX21

T33B0930/F1100-XX21

176/215 93/110 120/150 T33B1100-XX21

7号T33B1100/F1320-XX21

215/256 110/132 150/180 T33B1320-XX21

T33B1320/F1600-XX21

256/310 132/160 180/210 T33B1600-XX21

8号T33B1600/F1850-XX21

310/350 160/185 210/250 T33B1850-XX21

T33B1850/F2000-XX21

350/370 185/200 250/270 T33B2000-XX21

T33B2000/F2200-XX21

370/410 200/220 270/300

9号T33B2200-XX21

T33B2200/F2500-XX21

410/470 220/250 300/340 T33B2500-XX21

T33B2500/F2800-XX21

470/530 250/280 340/380 T33B2800-XX21

T33B2800/F3150-XX21

530/600 280/315 380/430

10号T33B3150-XX21

T33B3150/F3550-XX21

600/670 315/355 430/480 T33B3550-XX21

T33B3550/F4000-XX21

670/760 355/400 480/540 T33B4000-XX21

T33B4000/F4500-XX21

760/850 400/450 540/610

11号T33B4500-XX21

T33B4500/F5000-XX21

850/940 450/500 610/680 T33B5000-XX21

T33B5000/F5600-XX21

940/1050 500/560 680/760 T33B5600-XX21

T33B5600/F6300-XX21

1050/1140 560/630 760/850

12号T33B6300-XX21

6

T33B6300/F7100-XX21 1140/1340 630/710 850/960

T33B7100/F8000-XX21 1340/1500 710/800 960/1100

T33B8000/F10000-XX21 1500/1800 800/1000 1100/1350

1.7制动单元和制动电阻选择

变频器制动单元制动电阻

电压

容量

﹙KW﹚

配置

方式

规格用量

配置

方式

规格

220V 0.4 预置预置100W /200Ω 1 0.55 预置预置100W /200Ω 1

0.75 预置预置100W /200Ω 1

1.5 预置预置 200W/100Ω 1

2.2 预置预置300W/60Ω 1

3.7 预置预置500W/40Ω 1

380V 0.4 预置预置100W/1000Ω 1 0.55 预置预置100W/750Ω 1

0.75 预置预置200W/500Ω 1

1.5 预置预置300W/400Ω 1

2.2 预置预置500W/250Ω 1

3 预置预置500W/250Ω 1

4 预置预置800W/150Ω 1

5.5 预置预置1000W/100Ω 1 7.5 预置预置1200W/75Ω 1 11 预置外置1560W/60Ω 1 15 预置外置2000W/40Ω 1 18.5 预置外置3000W/30Ω 1 22 外置4030 1 外置3000W/30Ω 1 30 外置4030 1 外置4800W/25Ω 1 37 外置4030 1 外置6KW/20Ω 1 45 外置4030 1 外置6KW/20Ω 1 55 外置4045 2 外置10KW/16Ω 2 75 外置4045 2 外置10KW/16Ω 2 93 外置4045 2 外置10KW/13.6Ω 2 110 外置4045 2 外置10KW/13.6Ω 2 132 外置4045 3 外置10KW/13.6Ω 3 160 外置4045 3 外置10KW/13.6Ω 3 185 外置4220 3 外置40KW/3.2Ω 3

7

200 外置4220 3 外置40KW/3.2Ω 3

220 外置4220 3 外置40KW/3.2Ω 3

250 外置4220 4 外置40KW/3.2Ω 4

280 外置4220 4 外置40KW/3.2Ω 4

315 外置4220 4 外置40KW/3.2Ω 4

355 外置4220 5 外置40KW/3.2Ω 5

400 外置4220 5 外置40KW/3.2Ω 5

450 外置4220 5 外置40KW/3.2Ω 5

500 外置4220 6 外置40KW/3.2Ω 6

560 外置4220 6 外置40KW/3.2Ω 6

630 外置4220 6 外置40KW/3.2Ω 6

710 外置4220 6 外置40KW/3.2Ω 6

第二章安装和接线

本章为产品的基本“安装和接线”,使用前请仔细阅读本章的注意事项。

2.1机箱尺寸

8

9

W1W

D

H H 1

显示DISP PROG 设置

RUN 运行

停止

复位RESET

ENT

确认

JOG 点动

塑壳E00—E03

铁壳E04—E07(可透壁安装)

10

铁壳8号—12号

防护 等级 机箱号 外形尺寸 安装尺寸 W H D W1 H1 Φ IP21

0号 112 160 164 102 150 4.5 1号 162 230 168 148 212 5.5 2号 214 302 222 196 284 6.5 3号 252 360 238 230 338 6.5 4号 302 540 252 230 510 9.5 5号 370 598 290 250 568 9.5 6号 430 704 317 300 672 11.5 7号 510 795 347 380 759 11.5 8号 533 893 69 380 859 13.5 9号 591 941 375 410 907 13.5 10号 757 1297 430 555 1263 13.5 11号 879 1397 430 720 1367 13.5 12号 937 1637 430 780 1603 13.5 IP54

1号 177 300 173 148 284 6 2号 224 370 200 196 352 7 3号 260

425

229 203 408

7

4号-12号

尺寸与IP21系列一致

11

2.2基准型机箱安装要求

由于变频器属于精密的电力电子产品,其现场安装的好坏,环境的优劣直接影响变频器的正常工作 和使用寿命,故要求如下:

1)检查变频器安装地点的环境跟本手册第三章中“安全注意事项”是否相符,若不相符请不要安 装,否则会损坏变频器。

2)变频器使用了塑料零件,请不要在盖板上使用太大的力,小心安装,以免造成破损。 3)条件允许请将变频器背面或散热片露装于电控柜外,可以大幅度降低电控柜内产生的温度。 4)将变频器尽可能安装在清洁的场所,或可阻挡任何悬浮物质的封闭型屏板内。 5)变频器要用螺丝垂直且牢固地安装在安装板上。

6)注意变频器安装在电控柜内的散热方法:在两台或两台以上变频器以及通风扇安装在一个电控柜内时,应注意正确的安装位置,以确保变频器周围温度在允许值以内。如安装位置不正确,会使变频器周围温度上升,降低通风效果。

7)变频器可能达到很高温度(大约80℃),请安装在不可燃表面上(例如:金属),同时,为了使热量易于散发,应在其周围留有足够的空间。(见附图)

* 壁挂式变频器安装间隔距离以及安装环境中风扇位置

* 多台壁挂式变频器的安装I

* 多台壁挂式变频器的安装II

* 柜式变频器安装间隔距离以及安装环境中风扇位置

12

2.3接线要求

1)非专业人士请勿擅自接线。

2)变频器输出端不要安装移相电容,噪声滤波器或浪涌吸收器,勿接电阻性负载。

3) 请正确连接输出端与电机之间的电缆U、V、W,这将决定电机的旋转方向。

4)安装布线时应将电源线和控制电缆分开,例如使用独立的线槽等。如果控制电路连线必须和电源电

缆交叉,应成90度交叉布线。

5)使用屏蔽导线或双绞线连接控制电路时,确保未屏蔽之处尽可能短,条件允许时应采用电缆套管。

6)避免变频器的重力线(输出输入线)与信号线平行布线和集束布线,应分散布线。

7)检测器的连接线,控制用信号线,使用双绞屏蔽线,屏蔽线的外皮连接COM端。

8)变频器,电机等等的接地线接到同一点上。

9)加数据线滤波器到信号线上。

10)将检测器的连接线,控制用信号线的屏蔽层用电缆金属夹钳接地

13

14

2.4接线说明

注:多功能输入端子X1-X6为无源输入端子,有源控制线或控制线路感应带电会损坏变频器

1)主回路端子说明 端子记号 端子名称 说明 L 、N 单相输入端子 单相AC220V 50-60Hz R 、S 、T 三相输入端子 三相AC230V 或380V50-60 Hz U 、V 、W 变频器输出端子 接三相鼠笼电机 PB 制动端子 在P+、PB 之间连接制动电阻(22KW 以下) P+ 直流正端子 直流母线电源正极 P- 直流负端子 直流母线电源负极

15

PE 接地端子 变频器接地

2)控制回路端子说明

端子记号 端子名称 说明 TA 、TB 、TC 继电器触点输出 TA 、TC 为常开触点,TA 、TB 为常闭触点

SP 集电极开路输出 额定24V,50mA 输出 24V 、COM 24V 辅助电源 直流电源24V 输出(≤100mA ) X1 多功能输入端子1 功能由参数Pr044设定,出厂值为“正转启动” X2 多功能输入端子2 功能由参数Pr045设定,出厂值为“反转启动” X3 多功能输入端子3 功能由参数Pr046设定,出厂值为“停止” X4 多功能输入端子4 功能由参数Pr047设定,出厂值为“正转点动” X5 多功能输入端子5 功能由参数Pr048设定,出厂值为“第一段速” X6 多功能输入端子6 功能由参数Pr049设定,出厂值为“第二段速” 10V 频率设定辅助电源 与FV ,GND 连接电位器(4.7K-10K ) VF 、GND 频率设定电压输入 输入0-10V ,PID 给定或回馈 VS 、GND 频率设定电流输入 输入4-20mA ,PID 给定或回馈 V+、GND 0V-10V 输出 可用来指示频率、电流、电压、转速等 A+、GND 0-20mA 输出 可用来指示频率、电流、电压、转速等 A 、B 485通讯输入端子 利用电脑或其他上位机来进行远程通讯控制或监视

3)变频器主回路端子排:

* E00~E03机箱 三相380V/三相220V 下进下出式(X X )

P+P-PB PE

直流制动电阻

接大地

R S T PE 三相电源输入

接大地

电动机

U

V

W

16

* E00~E03机箱 三相380V/三相220V 上进下出式(S X )

R S T PE

接大地

三相电源输入

PE 接大地

电动机

U

V

W

P+P-PB 直流制动电阻

* E00~E02 单相220V 下进下出式(X X )

P+P-PB PE

直流制动电阻接大地

L

N PE 单相AV 220V输入接大地

电动机

U V

W

* E00~E02 单相220V 上进下出式(S X )

L N PE

接大地

单相AC 220V输入

PE

接大地

电动机

U

V

W

P+P-PB 直流制动电阻

17

* E04~E07 三相380V 下进下出式(X X )

R S T P-P1P+

U V

W

PE

接直流电抗器

三相电源输入

电动机

接大地

* E08~E10 三相380V 下进下出式(X X )

* E11~E12 三相380V 下进下出式(X X )

4 )主回路接线说明

* 电源及电机接线的压线端子。请使用带绝缘管的端子。 * 切记电源一定不能接到变频器输出端子上(U ,V ,W ),否则将损坏变频器。

* 接线后,零碎线头必须清除干净,零碎线头可能造成异常,失灵和故障,必须始终保持清洁。在控制台上打孔时,请注意不要使碎片粉未等进入变频器中。

* 为使电压压降在2%以内,请用适当型号的电线接线。变频器和电机间的接线距离较长时,特别是低频率输出的情况下,会由于主电路电缆的电压下降而导致电机的转矩下降。

18

* 线距离最长为300米,尤其长距离布线,由于布线寄生电容所产生的冲击电流会引起过电流保护动作,输出端连接的设备可能运行异常或发生故障。因此,最大布线距离按下表所示。(当变频器连接两台以上电机时,布线长度不得超过300米)

* 在P+,B-端子之间建议连接制动电阻器选件。

* 电磁波干扰:变频器输入,输出回路中含有谐波成分,在高要求场合请在输入端安装无线电噪音滤波器,使干扰降低到最小。

* 在变频器的输出端不要安装电力电容,浪涌抑制器和无线电噪音滤波器。这将导致变频器故障或器件损坏。

* 通电或运行后,要改变接线的操作,必须先停机后再切断电源10分钟以上,用万用表检查电压后进行,断电后一段时间内,电容上依然有危险的高压。 * 接地端子必须接地。

▲由于变频器内有漏电流,为了防止触电,变频器和电机必须接地。 ▲变频器接地用独立接地端子(不要用螺丝在外壳,底盘等代替)。

▲接地电缆尽量用粗的线径,必须等于或大于附表所示标准,接地线尽量靠近变频器,接地线愈短愈好。 ▲在变频器端接地的电机,用四芯电缆中的其中一接地,规格同输入线缆。

▲接线时应使变频器端子(P+,P-)与制动单元的端子记号相同,接错时会损坏变频器。 ▲制动单元,制动电阻单元之间的布线距离应在5米以内,即使用双绞线也不能超过10米。 ▲如果制动单元内的晶体管被损坏(短路),电阻将非常热,导致起火。因此,在变频器的输入端安装电磁接触器,可在故障时切断电源。

5)控制回路端子排:

A B GND A+X2X4X6VS VF

V+

X3X5COM

TC

TB TA

6)控制回路接线

* 端子“COM ”为控制信号的公共端,请不要将公共端接地。

* 控制回路端子的接线应使用屏蔽或双绞线,而且必须与主回路,强电回路分开布线。

* 由于控制回路的频率输入信号是微小电流,所以在接点输入的场合,为了防止接触不良,请使用两个并排的接点或使用双生接点。

* 控制回路建议用0.75平方毫米的电缆接线。 * 控制回路不能输入高压电,否则会损坏变频器 变频器与电机的接线距离 ≤50M ≤100M ≥150M 载波频率(Pr041的设定) ≤15KHZ ≤10KHZ ≤5KHZ

19

第三章 操作面板及安全事项

本章提供产品的基本“运行操作”说明,使用设备前请仔细阅读本章的内容。

3.1面板尺寸示意图

操作面板是人机沟通的接口,是由按键部分和显示部分组成,按键供用户输入控制指令,显示部分则显示参数资料和不同的运行状态。其外形如下图所示:

显示DISP

PROG

设置

正转

FWD 反转REV

RUN

运行

确认ENT 点动JOG

停止

复位RESET

3.2面板键盘按键说明

按键名称 功能说明

运行 按此键变频器开始运行,若设定为外部端子控制时,按此键无效。

正转/反转

按此键切换变频器运行方向,若设定为外部端子控制时或“Pr023”

设定为0时,不能反转运行。

停止/复位键

按此键变频器停止运行,若设定为外部端子控制时,按此键无效。

故障报警后,按此键系统复位。

设置 按此键即可进入功能设置状态,修改完毕,按此键退出功能设置状态。

确认/点动

在设置状态下按此键确认功能代码,参数内容修改后,再按此键。

将修改过的资料保存,在待机状态下(Prxxx=1)按此键执行点动功能。 ▲ 按此键使功能代码、参数资料数值增加。在运行或待机状态下按此键增大运行频率。

在设置状态下,按此键使功能代码,参数在运行或待机状态下按此键减少运行频率。

显示/移位键

在待机状态或运行状态下按此键可依次显示直流电压、输出电流、温度等, 具体参见1.2显示内容说明;在设置状态下修改参数资料时,可进行位移。

旋钮 面板编码器或电位器 当(Pr002=3),用以调节变频器运行频率。

20

3.3面板指示灯说明

指示灯名称 指示灯说明

FWD 灯闪烁表示变频器处于正转状态; REV 灯亮表示电机处于反转状态; Hz 频率指示灯灯亮面板示数为 :电机运行频率。 A 电流指示灯;灯亮面板示数为 :输出电流。 ROTT 电压指示灯;灯亮面板示数表示 :马达转速。

3.4参数修改方法

如果需要修改参数,首先要进入需要修改的功能码,然后进行参数值重新设定,具体步骤如下: 顺序 操作 说明 1 按 设置 键 显示Pr000,进入功能设置状态。 2 按 ▲ 与 ▼ 键 调整到需要修改的功能码。 3 按 确认/点动 键 显示PrXXX ,进入参数设置状态。 4 按 ▲ 与 ▼ 键 根据需要重新设定参数值。 5 按 确认/点动 键 存储资料,然后显示功能码PrXXX 6 按 设置 键 退出设置状态,回到待机或运行状态 3.5安全注意事项

1)本变频器手册包括有变频器使用时的操作说明和注意事项,不正确的使用可能会发生意想不到的事故,故使用变频器前,请仔细阅读本手册,正确地使用变频器并将此手册交给最终用户。

2)在仔细阅读本使用手册及附属数据并能正确使用前,请不要安装,操作,维护或检查变频器。 3)在熟悉机器的知识,安全信息以及全部有关注意事项以后使用。 4)在本手册中,将安全等级分为“危险”和“注意”。

危险:不正确的操作造成的危险情况将导致死亡或重伤的发生。

注意:不正确的操作造成的危险情况将导致一般或轻微的伤害或造成物体的硬件损坏,根据情况的不同,“注意”等级的事项也可能造成严重后果。 防止触电 * 当通电或正在运行时,请不要打开盖板,否则会发生触电。

* 在盖板拆下时请不要运行变频器,否则可能会接触到高电压端子和充电部分而造成触电事故。

* 即使电源处于断开时,除布线,定期检查外,请不要拆下盖板。否则,由于接触变频器充电回路可能造成触电事故。

* 布线或检查,请在断开电源 10 分钟以后,用万用表等检查剩余电压消失以后进行。 * 变频器请进行接地处理。(如不接地可能有 30-150V 感应电) * 包括操作或检查在内的工作都应由专业技术人员进行。 * 应在安装后进行布线,否则会造成触电或受伤。

变频器使用说明

产品说明 GS系列通用变频器是用于控制三相交流电动机速度的变频器系列。本系列有多种型号,额定功率范围从750W 到315kW的G型机(恒定转矩控制方式)或者P型机(可变转矩控制方式),供用户选用。 本变频器由高性能32位DSP微处理器控制,并采用具有现代先进技术水平的绝缘栅双极型晶体管(IGBT)作为功率输出器件。因此,它们具有很高的运行可靠性和功能的多样性。其脉冲宽度调制的开关频率是可选的,因而降低了电动机运行的噪声。全面而完善的保护功能为变频器和电动机提供了良好的保护。 1.1铭牌说明及命名规则 从包装箱取出变频器,检查产品铭牌,确认变频器型号,产品是否与定货单相符,机器是否有损坏,如有疑问或产品损坏,请与当地经销商联系。 铭牌说明: 变频器型号 输入电压相数、电压及频率 输出视在功率及电流 产品序列号 图1.1 铭牌示意图 命名规则:

1.2 GS系列变频器技术规范 GS系列变频器适用电机功率范围为:0.75~315kW。 1.2.1技术规范 项目规范 电源额定输入电压 (V) 三相380V +15%/-20%,50~60Hz±5% 输出额定输出电压 (V) 三相380V(与输入电压有关,可通过参数设置) 适用电机功率 (kW) 1.5 3.7 7.5 15 22 37 55 93 132 185 220 280 0.75 2.2 5.5 11 18.5 30 45 75 110 160 200 250 315 额定输出电流 (A) 3.8 9.0 17 32 45 75 112 176 253 355 426 540 2.1 5.1 13 25 37 60 91 150 210 304 380 480 610 最大过载电流 G型(200型):150% 1分钟,180% 2秒 P型(216型):120% 1分钟,150% 2秒 控制及运行 频率控制范围0~400Hz 输出频率精度0.01Hz 调速范围1:100 控制方式直线VF控制/多点VF控制/节能控制/磁通电流控制/转矩控制转矩提升手动转矩可调/自动转矩提升 启动转矩 G型:0.5Hz时150%的额定转矩 P型:0.5Hz时100%的额定转矩 电压/频率特性基本电压10V~440V可调,基本频率8Hz~400Hz可调 加、减速曲线直线和任意可调曲线,0.1~3200.0秒连续可调 频率设定输入 操作盒键盘、操作盒电位器、计算机、0~10V信号、4~20mA信 号及其组合 输入端子指令信 号 运转、正/反转、点动、多段速度、自由停车、复位、电压/电流 信号输入切换 输入端子 八个数字输入端子,其中一个可用作高速脉冲输入(0~50kHz) 二个模拟输入端子,一个只接收电压信号(0~10V),另一个可以 接收电压(0~10V)或电流信号(0~20mA) 输出端子 两个数字输出端子,其中一个可用作高速脉冲输出(0~50kHz) 二个模拟输出端子,可以输出电压信号(0~10V)或电流信号(0~ 20mA) 一个继电器输出 标准功能 电流限幅、手动转矩提升、自动转矩提升、自动稳定输出电压 (AVR)、转速追踪、启动直流制动、停车直流制动、瞬时停电再 起动、自动故障复位、频率上下限限制、跳跃频率功能、自动转 差补偿(转速补偿)、载波频率自动调整、自动节能运行、音调调 节、加减速模式可调、频率表和电流表输出、简易一拖二供水功 能、七段多段速度运行、程序运行、纺织用摆频功能、闭环PID 调节控制、注塑机节能改造(需配信号采集板) 保护功能 过压、欠压、外部故障、过流、电流限幅、过热、电子热过载继 电器、防过压(流)失速、数据保护 显示本机操作盒 参数设定:查看修改参数 运行显示:显示输出频率、输出电压等13种运行状态参数 故障显示:显示故障代码 计算机 通过内置串行通讯口与计 算机通讯 功能代码、数据、状态、图形

雷诺尔JJR软起说明书

JJR系列软起动器用户手册

目录 安全注意事项………………………………………………………………………………………安装准备……………………………………………………………………………………………使用及环境条件……………………………………………………………………………………1.概述……………………………………………………………………………………………… 典型应用简介…………………………………………………………………………………… JJR系列软起动功能……………………………………………………………………………2.购入检查…………………………………………………………………………………………3.安装………………………………………………………………………………………………4.电路连接………………………………………………………………………………………… 4.1主回路……………………………………………………………………………………… 4.2控制端子…………………………………………………………………………………… 4.3控制电路端子连接………………………………………………………………………… 4.4主回路连接………………………………………………………………………………… 4.5基本电路框图和端子………………………………………………………………………5.键盘及显示说明…………………………………………………………………………………6.数据的设定………………………………………………………………………………………7.通电运行…………………………………………………………………………………………8.保护显示说明……………………………………………………………………………………9.软起动控制模式………………………………………………………………………………… 9.1限流型……………………………………………………………………………………… 9.2电压控制型………………………………………………………………………………… 9.3软停车曲线………………………………………………………………………………… 9.4不同起动方式的电流波形比较……………………………………………………………10.结构特点………………………………………………………………………………………附表一应用场合……………………………………………………………………………………JJR1000系列二次接线图……………………………………………………………………………JJR2000系列二次接线图……………………………………………………………………………

丹佛斯变频器FC使用说明

丹佛斯变频器F C使用 说明 集团标准化小组:[VVOPPT-JOPP28-JPPTL98-LOPPNN]

使用说明 一、FC360的功能 二、FC360本机面板使用HandON 从出厂设定开始(未接控制线),首先,按【OffReset】键使变频器处于停止状态,设定参数5-12改为【0】,退出到Status状态,这时,还是【OffReset】键上的灯亮,按【OK】键,面板中心显示4位数值,设定手动频率,上下键增减,右键可窜位,设定好后,按【Handon】键计开始运行,运行过程中直接按键改变数值则立即更改输出。按【OffReset】键停止。设定的频率值将保持,再次按【Handon】键,将从运行最后的设定值。 三、FC360参数设定方法: 通用的参数设定方法:首先,按【OffReset】键使变频器处于停止状态,按【MENU】键显示OM1状态此时在按一次【MENU】键则进入菜单1模式,按上键或下键可以修改参数组号,按【OK】进入此参数组,按上下键找到你需要改的参数号,按【OK】键该设定参数值闪烁,按上下键修改参数值(功能代码),若按【ok】键保存此次修改的参数。若按【back】键则取消修改。 四、参数初始化 修改参数14-22设定为2(初始化),然后从新上电,此时报警为A80,按【OffReset】键复位后红色报警等已灭,但显示窗口仍有A80报警显示,变频器需再次从新上电。 五、参数复制到LCP面板。 修改参数0-50参数,当0-50,设为【1】所有参数到LCP,从变频器拷贝参数到面板,等待完成。

设为[2]则把面板中参数拷贝到变频器,从LCP传所有参数。 完成后参数自动改为【0】。 六、使用同步电机的设定步骤 按下表设定:

丹佛斯变频器说明书

xx变频器 按键功能: (DISPLAY/STATUS)键用于选择显示模式或者从快速菜单模式、菜单模式变回显示模式。 (QUICK MENU)键用于在快速菜单模式下进行参数编程。可以从快速菜单和菜单模式之间直接转换。 (MENU)键用于对所有参数进行编程。可以从菜单模式和快速菜单模式之间直接转换。 (CHANGE DATA)键用于在菜单模式或快速菜单模式下改变所选参数。 (CANCEL)键用于取消所选参数。 (OK)键用于确定和储存所选参数。 (+/-)键用于选择或改变所选参数。这些键也可在显示模式下使用。 (〈〉)键用于选择参数组和在改变数字参数时移动光标。 (STOP/RESET)键用于停止电机运作或用于VLT变频器跳闸后重新复位。 (JOG)键被按下时,它会将输出频率改变为预设的频率。 (FWD/REV)键改变在操作器显示屏上用箭头指示的电机旋转方向,(START)键用于启动通过(STOP/RESET)键停动的VLT变频器。该键始终处于有效状态,但不能超越由端子发出的停止命令。 操作步骤: 1、 2、 3、

4、 5、 6、按(MENU)键进入功能菜单。 按(+/-)或(〈〉)键选择参数。 按(CHANGE DATA)键进入数据改变模式。 按(+/-)键改变数据值。 按(OK)键存储改变的数据。 按(DISPLAY/STATUS)键返回到正常模式。 变频器故障内容 (10VOLTLOW)警告1:低于10V (LIVE ZERO ERROR)警告/报警2:电流信号零点故障 (NO MOTOR)警告/报警3:无电机 (DC LINK VOLTAGELOW)警告6:低电压警告 (DC LINK OVERVOLT)警告7:过电压 (DC LINK UNDERVOLT)警告/报警8:欠电压 (INVERTER TIME)警告/报警9:逆变器过载 (MOTOR TIME)警告/报警10:电机温度过高 (MOTOR THERMISTOR)警告/报警11:电机过热(热敏电阻)(TORQUE LIMIT)警告/报警12:过转矩极限(OVERCURRENT)警告/报警13:过电流 (EARTH FAULT)报警14:接地电流

A变频器操作说明书

1:启动2:停机3:激活给定参数设置4:正转 5:反转6:故障复位7:本地控制/远程(外部)控制1:如何启动,停机,改变运转方向 1:按(显示状态行)2:按(切换为本地模式:在显示屏第一 行没有字母L)3:按(停机)4:按(启动)5:按(反向运转)6:按(正向运转) 2:如何设置转速给定值 1:按(显示状态行)2:按(切换为本地模式:在显示屏第一行没有字母L)3:按(进入给定参数功能)4:按(慢速改变)或者 按(快速改变)5:按()(保存给定值) 3:如何选择在显示屏幕上的实际信号 1:按(进入实际信号显示模式)2:按(选择某一行,光标选择的地方就是你选择的地方)3:按(进入实际信号的选择功能)4:按(选择一个实际信号)或者按(改变实际信号组)5:按(确认并返回实际信号显示模式)或者按(取消所作选择,恢复原设置) 4:如何显示实际信号的全称 1:按保持(显示3个实际信号的全称)2:释放(返回实际信号选择模式)5:如何查看和清楚故障记录:注:故障或警告正在发生,则不能清楚故障记录 1:按(进入实际信号显示模式)2:按(进入故障记录显示功能)3:按(选择上条或下条故障/警告记录)4:按(清楚故障记录)5:按(返回实际显示信号) 6:如何显示和清楚当前故障记录 1:按(显示当前故障记录)2:按(将故障复位) 7:如何选择一个参数并改变参数值 1:按(进入参数模式)2:按(选择一个参数组)3:按 (在组内选择一个参数)4:按(进入参数设置功能)5:按(慢 速改变数字及文字)或者按(快速改变数字值,仅对数字)6:按 (储存新的参数值)或者按(为了取消新的设置并恢复原有设置,按任意一个模式选择键退出,并同时进入相应的模式) 8:启动向导的启动,浏览,退出 1:按(进入功能模式)2:按(从列出项中选择一个任务或功能项)或者按(翻页,以便显示更多的操作向导/功能项)3:按(进入所选任务)4:按(接受并继续)5:按(接受并继续) 6:按(慢速传调整动参数)或者按(快速调整传动参数)7:按(确认新值并进行下一步操作)或者按(取消设置并返回上一步)8:按+ (取消并退出) 9:如何将数据从传动单元上传至控制盘 1:按(进入功能模式)2:按(进入包含上传,下载和调节亮度功能的页面)3:按(选择上传功能:UPLOAD)4:按(执行上传功能) 5:按(切换至外部控制,在显示屏第一行没有L显示)6:断开控制盘的连接,连接到要接受数据的目标传动单元 10:如何将数据从控制盘下载至传动单元 1:将存有上传数据的控制盘连接到传动设备2:按(切换至本地控制模式) 3:按(进入功能模式)4:按(进入包含上传,下载和调节亮度功能的页面)

丹佛斯变频器FC360使用说明

丹佛斯变频器FC360使用说明

使用说明 一、FC360的功能 二、FC360本机面板使用HandON 从出厂设定开始(未接控制线),首先,按【Off Reset】键使变频器处于停止状态,设定参数5-12改为【0】,退出到Status状态,这时,还是【Off Reset】键上的灯亮,按【OK】键,面板中心显示4位数值,设定手动频率,上下键增减,右键可窜位,设定好后,按【Hand on】键计开始运行,运行过程中直接按键改变数值则立即更改输出。按【Off Reset】键停止。设定的频率值将保持,再次按【Hand on】键,将从运行最后的设定值。 三、FC360参数设定方法: 通用的参数设定方法:首先,按【Off Reset】键使变频器处于停止状态,按【MENU】键显示OM1状态此时在按一次【MENU】键则进入菜单1模式,按上键或下键可以修改参数组号,按【OK】进入此参数组,按上下键找到你需要改的参数号,按【OK】键该设定参数值闪烁,按上下键修改参数值(功能代码),若按【ok】键保存此次修改的参数。若按【back】键则取消修改。 四、参数初始化 修改参数14-22设定为2(初始化),然后从新上电,此时报警为A80,按【Off Reset】键复位后红色报警等已灭,但显示窗口仍有A80报警显示,变频器需再次从新上电。

五、参数复制到LCP面板。 修改参数0-50参数,当0-50,设为【1】所有参数到LCP,从 变频器拷贝参数到面板,等待完成。 设为[2]则把面板中参数拷贝到变频器,从LCP传所有参数。 完成后参数自动改为【0】。 六、使用同步电机的设定步骤 按下表设定: ID Description Description FC-360设定值FC360-22K 100 Configuration Mode 配置模式open loop 0 101 Motor Control Principle 电动机控制原理VVC+ 1 110 Motor Construction 电动机机构PM, non salient SPM 1 124 Motor Current Inom [A] 电机额定电流电机名牌34 125 Motor Nominal Speed [RPM] 电机额定转速电机名牌1000 126 Motor Cont. Rated Torque Mnom[Nm] 电动机持续额定转 矩 电机厂家提供155 129 AMA 自动电动机调整可以做AMA自学习高级参数[1],[hand ON],等待--, [OK] 130 Stator Resistance Rs [Ohm] 定子阻抗Rs电机厂家提供数值除以2 (110)可学习, 137 d-axis Inductance Ld [mH] d轴电感Ld 电机厂家提供数值除以2 (3.6)可学习 139 Motor Poles 电机级数电机极数(8)可学习 140 Back EMF at 1000 RPM [V_RMS/1000RPM] 1000转时后感应电 势 电机厂家提供320(手动输入) 142 Motor Cable Length 电缆长度(M)单位米30

变频器使用说明书(SHUPER)

. 第一章安全注意事项与检查 1.1 安全注意事项 ●绝不可将交流电源接至变频器输出端U、V、W等端子。 ●在接通电源后,不可实施配线,检查等作业。 ●关闭电源,在键盘显示熄灭后5分钟之内,请勿触摸机内电路板及 任何零部件,且必须用仪表确认机内电容已放电完毕,方可实施机内作业,否则有触电的危险。 ●人体静电会严重损坏内部MOS场效应电晶体等,未采取防静电措 施时,请勿用手触摸印刷电路板及IGBT等内部器件,否则可能引起故障。 ●使用时,变频器的接地端子(E或〨)请依据国家电气安全规定和 其它有关标准正确、可靠的接地。 ●本装置在通电后,请勿接触内部线路板及其元器件,以免触电危险。 ●请勿以拉闸方式(断电)停机,等电机运行停止后才可断开电源。 ●符合CE标准必须增加选购输入滤波器附件。 特别注意: 只有训练有素的人员允许操作本装置,使用前请详细阅读本说明书中有关安全、安装、操作和维修部分。本设备的安全运行取决于正确的选型、安装、操作和维护! ..

1.2 开箱之后检查 烁普SP500系列变频器在出厂之前均已经过测试和品质检验。在购买后,开箱之前请检查产品的包装是否因运输不慎而造成损伤,产品的规格、型号是否与订购之机种相符。如有问题,请联络本公司或经销厂商。 ●检查内部:含本机、使用说明书一本、保修卡一张。 ●检查变频器侧面的铭牌,以确定您手上的产品就是所订购之产品型号说明:

. 第二章安装及配线 2.1 使用环境 (1)环境温度-10℃—40℃; (2)避免震动; (3)避免高温多湿且无雨水滴淋,湿度小于90%RH(不结露); (4)防止油、盐及腐蚀性气体侵入; (5)防止水滴、蒸气、粉尘、灰尘、棉絮、金属细粉的侵入; (6)防止电磁干扰、远离干扰源; (7)禁止使用在易燃性、可燃性、爆炸性气体、液体或固体的危险环境。 2.2 安装方向与空间 变频调速器要安装于室内通风良好的场所,并采用壁挂式或立柜式。并与周围相邻物品或挡板(墙)必须保持足够的空间。如下图所示: ..

变频器操作说明完整版

变频器操作说明 HEN system office room 【HEN16H-HENS2AHENS8Q8-HENH1688】

S120操作说明 1、面板(BOP)操作: 1)、传动对象的选择: 面板显示屏左上角显示的数字是被激活的传动对象,对应控制单元CU320及其控制下的功率模块。 同时按“FN”和“向上”键,可以该数字闪烁,通过上下键的选择,即可显示选择的传动对象。 其中,对于1#控制单元(+Z2DKG02柜): 01代表1#控制单元CU320; 02代表整流单元; 03代表1#步进冷床前回转臂拨料机控制系统; 04代表2#步进冷床前回转臂拨料机控制系统。 对于1#控制单元(+Z2DKG04柜): 01代表2#控制单元CU320; 02代表4#链式冷床控制系统; 03代表1#链式冷床控制系统; 04代表1#步进冷床控制系统; 05代表2#步进冷床控制系统。 选择操作对象,即可对相应对象进行操作,以及查看状态等。 注意:传动对象在显示参数值时不可更改,即显示“P”或“r”时方可更改。 2)、参数的更改: 在选择好传动对象后,可以进入想要查找的参数。改变参数值,须先按动“FN”键,相应的参数位闪烁后方可通过上下键更改,按“P”键确认。 如果不能找到想要查看的参数,须回到传动对象为控制单元(即传动对象显示01),将参数P0003=3,可显示完全参数列表。 参数改动后,显示屏中“S”出现,说明参数存储区“RAM”和“ROM”不一致,此时须常按“P”键三秒钟,将参数写入ROM。 3)、故障复位: 控制单元报故障,面板上方红色故障灯点亮,需按“FN”键进行复位。 2、常用参数: r21 输出频率 r27 输出电流 r31 电机输出转矩 r61 编码器实际值 r26 直流母线电压 r2090 由自动化发送的控制字1(位显示) 由自动化发送的控制字2(速度给定) 发送给自动化的状态字1(位显示) 发送给自动化的状态字2(位显示)

丹佛斯变频器操作说明

。韻㈣解观 8 W *世幽鸽敷醐敝翻的聘擱 ? (9NlNaVM)号哥(NO)财醃骗临的馳g≡ £中?≡桦黜躺冀?豳釧幅劉懾e≡辭屋SO蜩鮒罪“巾昭Iil翹钿。i ?i?≡≡ι £[?ι^≡^≡ P 坐般鼬* Iim i≡i2,?≡δ?? P 购鶴 S≡ 釧 ≡'s 馳轿T ≡ E 翩她≡S Z 豐M I ≈msι^≡?f∣ ?MK UJε 卿 ∏Λ播弼释牖題離鵬虞■刪圈擱進说辭Oi搁韓ΠΛ Kfeft删胁(S 8?跚搁)Q ■鶴搁H-認虫鱷麵口A ≡3≡dσι ■

■讀示屏聶 LCD 删俪■ T IfflWSg!W* Ii示髓≡ra瀬/融中謬。■瀏獗删勰分衲別细分按漑於濃騎模琳鯛參決 τaι≡8smw≡ * 第-厅用任持飜示操作临下SEIB鉤賊說明磯二行揀示8≡)證“ 第二厅前了齣或谿2那任畝況下牒爾 ?sss≡≡t≡* 第三行-曲空白■它用於騎馨軾下腿细號嶋輔鮒细組頼挪* 瓢厅用於弔那軾下騎般文字或側翱據 軾下騎鱷细的勲或麴≡ ? 箭頭騎髓躋方向、並且同髒示在麴004癮鹏殡疽肄釦齡:俵勒炖肄临訓和擢劇騎於石方並閃動。IDlSPLAY/STATUS]可選離禱蹶做凝單或義輾趣骐腮, [QUICK MENU]可症入険表軍麴-也可在驱表艱表範髒珑≡f簸i IMENuI丸丽勺礪參執也巧描及快港肄2髓?? 第-行 口?Ξfj 輒行

[CHANGE DATA]可更改戎單或快逸表單?M式下所選擇的設定* [CANCEL]取消史改選迁:的蔘數設定- [OKJ砖認選丄參數的車改SS定4 [÷A]用於選擇或改翌所選蔘数? [<>]用於選擇蔘數組和在改變數字値參戟時移動光嘿- [STOpyRESETJ可用於停止馬達連作或便愛頻器跳脫後重新幺訓祗注皂幸小014 ^?'2..√1?√Λ: 7/ [STOP; RESET]淤握匸勻效狀態下按下此鍵後第二行顯示將會閃爍* [JCX3]可用於將晦出頻率改矍為頊設旳頻率(寸動頻率)。該 S?可用參數Cn5來使冥有效或無效* [FWD/REV]用於改锲馬達πkΦS75∣A)?馬達方向將在顯示唐蒂上以箭閒旨示顯示◎該鍵可透過裁?S CM 6來便冥有效或無效* [STARTJ用宾已動透适[STOP/RESET]誕停止旳燮頻器。該匙始終虛於勻效狀態?但不能超趣由端子醴出的停止命令恤先於[START]扌旨令- 注意! 如果燥作鎚虛於有效狀態?無諱愛頻器的證定是用**操作??控制"還是M?A?li?RU,'(參數∞2) 們都將保持有效。除了[FWD∕RE?η 雜只有在進行操作器操作時刁勻效4 B 注意! IiSl 如果沒角選擇込部停俶功Sg *而ISTOFI 鍵塩於無—敕狀態時'則運轉中的馬達只能渗過切斷 電源來停

ABB变频器使用说明书

一、环境条件 ?防护等级 ?IP21/UL 1:这个等级要求安装现场无粉尘,无腐蚀性气体或液体,无导电性颗粒物,例如凝露、碳粉或小金属颗粒。 ?IP54/UL 12:这个等级可以提供对气体粉尘以及各个方向的轻度溅水的保护。 与IP21/UL 1 的防护等级相比,IP54/UL 12防护等级具有以下特点: ?与IP21/UL 1 的防护等级相同的内部塑料罩。 ?不同的出风口侧塑料盖板。 ?附加一个内部风扇以改善冷却。 ?更大的外部尺寸。 ?同样的容量(不需要降容使用)。 ?环境条件 1、海拔高度 ?海拔高度在0~1000米时,输出电流=I2N 额定电流 ?海拔高度在1000~2000米时,每升高100米则P N和I2N 降容1%。 ?如果安装地点海拔高度高于2000米,请联系当地的ABB变频器。 2、环境温度 ?最低温度-15℃-不允许有结霜。 ?最高温度(fsw=1或4KHZ)为40℃。fsw指开关频率 ?如果P N和I2N 降容到90%时,允许温度为50℃. ?如果P N和I2N 降容到80%时,允许最高温度(fsw=8KHZ)为40℃。 ?如果P N和I2N 降容到65%时,允许最高温度(fsw=12KHZ)为30℃. ?温度在40~50℃之间,温度高于40℃时(fsw=4KHZ)每增加1℃,额定输出电流降低1%。实际输出电流要乘以降容因子 例如:如果环境温度是50℃,那么降容因子为 100%-1%/℃x10℃=90%或0.90 则输出电流为0.90 xI2N 。 3、相对湿度 ?小于95%(不允许结露) 4、污染级别 ?不允许有导电性粉尘存在。 ?ACS510应根据外壳防护等级安装在清洁的通风环境中。 ?冷却空气必须是清洁的,无腐蚀性气体和无导电性粉尘。 ?化学气体:Class 3C2 ?固体颗粒:Class 3S2

A 变频器操作说明书

1:启动 2:停机 3:激活给定参数设置4:正转 5:反转 6:故障复位 7:本地控制/远程(外部)控制 1:如何启动,停机,改变运转方向 1:按(显示状态行) 2:按(切换为本地模式:在显示屏第一 行没有字母L) 3:按(停机)4:按(启动)5:按(反向运转) 6:按(正向运转) 2:如何设置转速给定值 1:按(显示状态行)2:按(切换为本地模式:在显示屏第一行没 有字母L)3:按(进入给定参数功能)4:按(慢速改变)或者 按(快速改变)5:按()(保存给定值) 3:如何选择在显示屏幕上的实际信号 1:按(进入实际信号显示模式)2:按(选择某一行,光标选择的地 方就是你选择的地方)3:按(进入实际信号的选择功能)4:按(选择一个实际信号)或者按(改变实际信号组) 5:按(确认并返回

实际信号显示模式)或者按(取消所作选择,恢复原设置) 4:如何显示实际信号的全称 1:按保持(显示3个实际信号的全称) 2:释放(返回实际信号选择模式) 5:如何查看和清楚故障记录:注:故障或警告正在发生,则不能清楚故障记录1:按(进入实际信号显示模式)2:按(进入故障记录显示功能) 3:按(选择上条或下条故障/警告记录) 4:按(清楚故障记录) 5:按(返回实际显示信号) 6:如何显示和清楚当前故障记录 1:按(显示当前故障记录) 2:按(将故障复位) 7:如何选择一个参数并改变参数值 1:按(进入参数模式)2:按(选择一个参数组)3:按(在组内选择一个参数) 4:按(进入参数设置功能) 5:按(慢 速改变数字及文字)或者按(快速改变数字值,仅对数字)6:按(储存新的参数值)或者按(为了取消新的设置并恢复原有设置,按任意一个 模式选择键退出,并同时进入相应的模式) 8:启动向导的启动,浏览,退出 1:按(进入功能模式) 2:按(从列出项中选择一个任务

丹佛斯变频器说明书

丹佛斯变频器 按键功能: (DISPLAY/STATUS)键用于选择显示模式或者从快速菜单模式、菜单模式变回显示模式。 (QUICK MENU)键用于在快速菜单模式下进行参数编程。可以从快速菜单和菜单模式之间直接转换。 (MENU)键用于对所有参数进行编程。可以从菜单模式和快速菜单模式之间直接转换。 (CHANGE DATA)键用于在菜单模式或快速菜单模式下改变所选参数。 (CANCEL)键用于取消所选参数。 (OK)键用于确定和储存所选参数。 (+/-)键用于选择或改变所选参数。这些键也可在显示模式下使用。 (〈〉)键用于选择参数组和在改变数字参数时移动光标。 (STOP/RESET)键用于停止电机运作或用于VLT变频器跳闸后重新复位。 (JOG)键被按下时,它会将输出频率改变为预设的频率。 (FWD/REV)键改变在操作器显示屏上用箭头指示的电机旋转方向,(START)键用于启动通过(STOP/RESET)键停动的VLT变频器。该键始终处于有效状态,但不能超越由端子发出的停止命令。 操作步骤: 1、按(MENU)键进入功能菜单。 2、按(+/-)或(〈〉)键选择参数。 3、按(CHANGE DATA)键进入数据改变模式。 4、按(+/-)键改变数据值。 5、按(OK)键存储改变的数据。 6、按(DISPLAY/STATUS)键返回到正常模式。 变频器故障内容

(10VOLTLOW)警告1:低于10V (LIVE ZERO ERROR)警告/报警2:电流信号零点故障 (NO MOTOR)警告/报警3:无电机 (MAINS PHASE LOSS)警告/报警4:缺相 (DC LINK VOLTAGE HIGH)警告5:高电压警告 (DC LINK VOLTAGELOW)警告6:低电压警告 (DC LINK OVERVOLT)警告7:过电压 (DC LINK UNDERVOLT)警告/报警8:欠电压 (INVERTER TIME)警告/报警9:逆变器过载 (MOTOR TIME)警告/报警10:电机温度过高 (MOTOR THERMISTOR)警告/报警11:电机过热(热敏电阻)(TORQUE LIMIT)警告/报警12:过转矩极限(OVERCURRENT)警告/报警13:过电流 (EARTH FAULT)报警14:接地电流 (SWITCH MODE FAULT)报警15:载波模式故障 (CURR.SHORT CIRCUIT)报警16:短路 (STD BUSTIMEOUT)警告/报警17:标准总线无信号 (HPFB BUS TIMEOUT)警告/报警18:HPFB总线无信号 (EE ERROR POWER CARD)警告19:电源卡EEPROM故障 (EE ERROR CTRL CARD)警告20:控制卡EEPROM故障(AUTO MOTOR ADAPT OK)报警21:自动适配正常 (BRAKE TEST FAILED)警告和报警22:制动核查中的故障(BRAKE RESISTOR FAULT)警告23:制动电阻故障 (BRAKE PWR WARN 100%)警告24:制动电阻率100% (BRAKE IGBT FAULT)警告25:制动晶体管故障

雷诺尔软起动器的参数设置

雷诺尔软起动器的参数设置 洪达化工部分低压柜采用的是上海雷诺尔公司生产的软起动器,主要设置以下参数: 、起始电压(代码 00):设定范围30-80%,出厂值:30%,—般轻负荷设为 30%,重负 荷设为50%,特重负荷设为80%,具体设置根据现场实际情况及个人经验设置。 、保护级别(代码 0C ):设定范围1-5,出厂值:1,这个保护主要用于电机过载保护,电 机过载保护级别共分为 5个级别,设定范围1-5, 2级为标准保护级别,设定为1级对 电机的最快速保护,用户可根据负载轻重的不 同, 设定不同的保护级别。级别越高,适 用的负载就越重。 、负载调节率(代码11):设定范围50-100%,出厂值为100%,在用户选用的软起动额 定参数不与实际电机匹 配时, 为了使保护功能和显示参数的正确, 应该重新设定负载调 节率。 方法一:负载调节率(KT )=实际电机功率( Ps ) % 软起动器功率(Pr ) % 方法二:负载调节率(KT )= 电机的额定电流 % 软起动器的额定电流 ° 举例:电机功率为160KW ,软启动的功率为 200KW ,其负载调节率就是 80%(160/200)。 四、 上升时间(代码 01)设定范围0-100S ,出厂值为10S ,具体设置根据现场实际情况及 个人经验设置。 五、 限制倍数(代码04)设定范围150%-500%,出厂值250%,重载和限流模式有效。 限流倍数= 电机额定电流 X 以几倍的额定电流启动 软起的额定电流 举例:电机的额定电流为 320A ,软启动的额定电流为 400A ,以电机2.5倍的额定电流 启动,其限流倍数就等于 320X2.5/400,为200%。 十一、 故障继电器(代码12)设定范围 以上是雷诺尔软起动器的部分主要参数, 设置参照说明书,根据现场实际情况及个人经验设置。 六、停车时间(代码 02)设定范围 0-60S ,出厂值2S , 0为自由停车 七 、 瞬停设定 (代码 05) 设定范围 0-1, 出厂值0S ,0 :瞬停无 1:瞬停有 八、 起动模式 (代码 08) 设定范围 0-2, 出厂值1 ; 0: 限流1: 电压, 2: 重载 九、 控制方式 (代码 09) 设定范围 0-5, 出厂值0; 0: 键盘1: 外控, 2: 键盘+外控, PC ,4: 键盘+PC 5 : 外控+PC 十、 缺相控制(代码 0A ) 设定范围 0-1, 出厂值1; 0: 缺相无 1:缺相有 3: 0-1,出厂值0,0:常开,1:常闭 (加黑部分为我厂软起动器设置的参数)具体

丹佛斯变频器FC360使用说明

使用说明 一、FC360的功能 二、FC360本机面板使用HandON 从出厂设定开始(未接控制线),首先,按【Off Reset】键使变频器处于停止状态,设定参数5-12改为【0】,退出到Status状态,这时,还是【Off Reset】键上的灯亮,按【OK】键,面板中心显示4位数值,设定手动频率,上下键增减,右键可窜位,设定好后,按【Hand on】键计开始运行,运行过程中直接按键改变数值则立即更改输出。按【Off Reset】键停止。设定的频率值将保持,再次按【Hand on】键,将从运行最后的设定值。 三、FC360参数设定方法: 通用的参数设定方法:首先,按【Off Reset】键使变频器处于停止状态,按【MENU】键显示OM1状态此时在按一次【MENU】键则进入菜单1模式,按上键或下键可以修改参数组号,按【OK】进入此参数组,按上下键找到你需要改的参数号,按【OK】键该设定参数值闪烁,按上下键修改参数值(功能代码),若按【ok】键保存此次修改的参数。若按【back】键则取消修改。 四、参数初始化 修改参数14-22设定为2(初始化),然后从新上电,此时报警为A80,按【Off Reset】键复位后红色报警等已灭,但显示窗口仍有A80报警显示,变频器需再次从新上电。

五、参数复制到LCP面板。 修改参数0-50参数,当0-50,设为【1】所有参数到LCP,从变频器拷贝参数到面板,等待完成。 设为[2]则把面板中参数拷贝到变频器,从LCP传所有参数。 完成后参数自动改为【0】。 六、使用同步电机的设定步骤 按下表设定:

2、在网络上添加新设备,FC-360(图是FC300的) 3、选择PPO类型

丹佛斯变频器说明书

xx变频器 按键功能: (DISPLAY/STATU碘用于选择显示模式或者从快速菜单模式、菜单模式变回显示模式。 (QUICK MENU键用于在快速菜单模式下进行参数编程。可以从快速菜单和菜单模式之间直接转换。 (MENU)键用于对所有参数进行编程。可以从菜单模式和快速菜单模式之间直接转换。 (CHANGE DATA键用于在菜单模式或快速菜单模式下改变所选参数。 (CANCEL键用于取消所选参数。 (OK)键用于确定和储存所选参数。 (+/-)键用于选择或改变所选参数。这些键也可在显示模式下使用。 (〈〉)键用于选择参数组和在改变数字参数时移动光标。 (STOP/RESET键用于停止电机运作或用于VLT变频器跳闸后重新复位。 (JOG键被按下时,它会将输出频率改变为预设的频率。 (FWD/REV键改变在操作器显示屏上用箭头指示的电机旋转方向,(START键用于启动通过(STOP/RESET键停动的VLT变频器。该键始终处于有效状态,但不能超越由端子发出的停止命令。 操作步骤: 1、 2、 3、

4、 5、 6、按(MENU)键进入功能菜单。 按(+/-)或(〈〉)键选择参数。 按(CHANGE DATA键进入数据改变模式。 按(+/-)键改变数据值。 按(O的键存储改变的数据。 按(DISPLAY/STATUSt返回到正常模式。 变频器故障内容 (10VOLTLOW 警告1 :低于10V (LIVE ZERO ERRO噜告/报警2:电流信号零点故障 (NO MOTOR警告/报警3:无电机 (DC LINK VOLTAGELO哗告6:低电压警告 (DC LINK OVERVOL诰告7:过电压 (DC LINK UNDERVOL诰告/报警8:欠电压 (INVERTER TIME警告/报警9:逆变器过载 (MOTOR TIME警告/报警10:电机温度过高(MOTOR THERMISTO曜告/报警11:电机过热(热敏电阻) (TORQUE LIMIT警告/报警12:过转矩极限(OVERCURREN啪告/报警13:过电流

变频器使用手册

中压变频调速装置 使用手册TK2000-200系列 大港油田中成机械制造有限公司

本手册的解释权属中成公司。用户在使用TK2000-200的过程中有技术或工程上的问题,请与中成公司联系。 本手册一般随中压变频装置一起供货,未经本公司许可,用户不得以任何方式对外泄露本手册的内容。

目录 一、概述 1 二、主要技术性能指标 2 三、结构和工作原理 3 四、尺寸重量 6 五、安装 6 六、使用操作 7 七、故障分析与排除 10 八、出现故障时处理程序和方法 11 九、保养与维护 11 十、运输、贮存 11 十一、开箱及检查 12 十二、订货须知 12

一、概述 1、中压变频装置特点 我公司的HYVER-MV中压变频器是根据油田采油潜油泵而设计的专用的变频调速装置。该产品已通过了机电部天津电气传动研究所的型式试验,已通过了由市科委组织的新产品鉴定。该变频器与通用的中压变频器相比具有独特的三电平、中点电位自动箝位的优点,结构简单,可靠性高。输出纹波及电源侧谐波分量小,智能化程序高等特点。属真正的高——高方案。技术特点: 1)每个主管承受的关断电压仅为1/2直流环节电压; 2)变频器输出的电压减少了dv/dt对电机、电缆的绝缘冲击; 3)三电平的拓扑结构; 4)开关损耗小,易散热; 5)中点电位自动箝位; 6)输出阶梯正弦PWM波形,输出加装电抗器,对电机、电缆绝缘无损害; 7)具有参数设定功能; 8)具有LED显示。 2、适用范围 TK2000-200中压变频器主要用于油田潜油电泵的调速,同时也适用于输油泵、注水泵、城市用水工程、输水回压泵、城市水厂水泵、电力行业的风机、水泵、火力辅机、钢铁行业的送风机、引风机、排水泵、采矿业的风机、排水泵等。 3、产品品种规格 1)功率:45KW-200KW;

雷诺尔变频器

电工培训资料(一) 上海雷诺尔变频器(功能使用设置、故障代码及处理方法) 一、控制面板功能说明 1、F UN键;按下FUN键进入设置菜单F00; 2、按住上键或下键翻滚到需要设置的代码; 3、此时在按FUN键确认,进入参数调整到需要的数值; 4、调整完毕后按WR储存键,这时面板显示E2—或YE5—时,新数值写入有效, 显示E┲┲—时新输入数值储存无效; 5、设置完成后按FUN键返回到设置代码,按向下键或向上键到F00,在按FUN 返回到初始菜单; 二、代码功能说明; 1、F00主设定/观测窗口; 2、F01输入频率下限0.00~40.00HZ;出厂值为0HZ,限定开环设定最小值; 3、F02输入频率上限20.00~600.0HZ;出厂值为50.0HZ. 4、F03基本频率26.0~600.0HZ;出厂值为50.0HZ. 5、F04命令模式0-键盘;1-端子正/反转模式;2-备用;3-端子自保持模式;4-RS485 串行口通信模式;出厂值设定为0;自保持模式需要外部辅助端子(X4)配合见F56; 6、F05主设定源选择0-键盘数字给定,1-内部多段速给定,2-端子模拟电压VG 给定(0~10V),3-端子模拟电流Ig(0~20mA)给定,4-端子模拟电流Ig(4~20mA)给定,5-电动电位器给定、相关参数F54,6-RS48串行接口给定,7-复合多段速模式0.10~999.9sec、运行命令及方向由F04决定;出厂值为0; 7、F06第一加速时间0.10~999.9sec,出厂值为5.0sec;△第一加减速参数与第 二加减速参数切换由端子X3选择(见F55); 8、F07第一减速时间0.10~999.9sec,出厂值为5.0sec;△第一加减速参数与第 二加减速参数切换由端子X3选择(见F55); 9、F08弧线时间0.0~50HZ,0.0sec;△第一加减速参数与第二加减速参数切换由 端子X3选择(见F55); 10、F09第二加速时间0.10~999.9sec;5.0sec;△第一加减速参数与第二加减 速参数切换由端子X3选择(见F55); 11、F10第二减速时间0.10~999.9sec;5.0sec;△第一加减速参数与第二加减 速参数切换由端子X3选择(见F55); 12、F11备用0.0~50.0sec;0.0sec; 13、F12备用0.0~50.0sec;0.0sec; 14、F13停机模式0-软停止;1-立即停止; 15、F14再启动模式0-为禁止再启动,1-为安记忆频率及相位跟踪再启动,2- 为按测速频率跟踪再启动,3-按常规上电延时再启动;出厂值为0;跟踪过程中运行信号解除立即停止跟踪此时与F13无关;跟踪有效时将忽略启动直流自动;测速模式必须安装编码器; 16、F15转速跟踪调节时间100~9999ms,出厂值为1000ms; 17、F16转速跟踪电流限制30.0~300.0%;出厂值100.0%; 18、F17自动跟踪调节时间5.0sec~600.0sec,出厂值10.0sec,600.0sec相当 于不解除跟踪;

快速门变频器使用说明书

目录 1前言 (1) 2安全使用注意事项 (2) 3键盘面板操作 (3) 4快速调试 (4) 使用机械限位开关 (4) 使用绝对值编码器 (5) 使用增量式编码器 (6) 5功能参数说明 (7) 基础功能 (7) 速度调节 (8) 编码器模式 (9) 运行时间及保护 (10) V/F曲线、开关量输出 (11) 通讯 (12) 通用型变频器模式 (12) 6故障信息及排除 (13)

7电气接线图 (15)

1 前言 感谢您选用多功能、高性能的研和C102双核(双CPU)快速门控制系统。本产品性能稳定、控制参数界面友好、功能强大、方便调试和维护。可配套控制PVC快速卷帘门、堆积门、硬质快卷门等工业门类。 产品特点: 1、可选择机械限位开关、绝对值编码器、增量式编码器控制模式。 2、内置卷帘门控制的核心芯片;双CPU。 3、体积更小,功能更强;380V/统一安装尺寸。 4、具备双门互锁且自动开门、风帘机控制、门上升到位、门下降到位、手动不联锁/自动联锁功能。 5、具备编码器控制模式下全开/半开功能、拉绳开关功能。 6、可直接显示编码器位置数据。 7、恢复出厂值、密码保护、电机双重保护功能。 8、设定及故障均有提示或报警代码,方便调试及维护。 9、全部输入信号均可参数实时监控。 10、变频器、PLC合二为一,高度集成。

2 安全使用注意事项 1、实施配线前,请务必关闭电源。 2、切断交流电源后,指示灯未熄灭前,表示变频器内部仍有高压,十分危险,请勿触摸内部电路及零部件。 3、运转时,请勿检查电路板上零部件及信号。 4、请勿自行拆装更改变频器内部连接线、线路及零部件。 5、所选用电源电压必须与变频器输入电压规格相同。 6、请确认将电机及变频器正确接地,以确保安全。 7、请确保主回路端子配线正确,电源输入、电机输出接线正确,否则,将造成变频器的损坏报废。 8、送电前请盖好电箱门,以防触电,造成人身伤害。 请详细阅读本使用说明书,以便正确安装使用,充分发挥其功能,并确保安全。请永久保存此说明书,以便日后保养、维护、检修时使用。 为了您的安全,请务必由专业的电机工程人员安装、调试及调整参数。您在安装、运转、检查变频器时的安全防范事项,请您务必遵守,使变频器使用更加安全。若有疑虑,请联络本司或代理商,专业人员乐于为您服务。本机器、控制软件、说明书如有升级变动,恕不另行通知。

相关主题
文本预览
相关文档 最新文档