建筑工程学院

混凝土结构课程设计项目名称:某四层办公楼结构设计

目录

一.设计任务书----------------------------------------------------(1)二.结构计算书----------------------------------------------------(2)

1.结构布置--------------------------------------------------(2)

2.计算简图--------------------------------------------------(2)

3.荷载计算-------------------------------------------------(3)

(1)恒荷载------------------------------------------------(3)

(2)活荷载------------------------------------------------(5)

(3)风荷载------------------------------------------------(6)

4.内力分析--------------------------------------------------(7)

(1)恒荷载作用下的内力计算------------------------(7)

(2)活荷载作用下的内力计算------------------------(10)

(3)风荷载作用下的内力计算------------------------(14)

5.内力组合--------------------------------------------------(16)

6.截面设计--------------------------------------------------(17)

(1)梁的设计--------------------------------------------(24)

(2)柱的设计--------------------------------------------(26)三.设计图纸

(一)梁柱配筋施工图-------------------------------------------(29)(二)各截面配筋详图-------------------------------------------(30)附:柱钢筋表-------------------------------------------------------(31)梁钢筋表-------------------------------------------------------(31)附录-------------------------------------------------------------------(32)致谢-------------------------------------------------------------------(33)

一、某四层办公楼混凝土框架结构设计任务书

设计资料

设计标高:室内设计标高+-0.000相当绝对标高4.400米,室内外高差600mm。

墙身做法:墙身为普通机制砖填充墙,用M5混合砂浆砌筑。内粉刷为混合砂浆底,纸筋灰面,厚20mm,内外涂料两度。外粉刷为1:3水泥砂浆底,厚20mm,陶瓷锦砖贴面。

楼面:楼板顶面为20mm厚水泥砂浆找平,5mm 厚1:2水泥砂浆加“108”胶水找色粉面层,板底为15mm厚纸筋面石灰抹底,涂料两度。

屋面:现浇楼板上铺膨胀珍珠岩保温层(檐口处厚100mm,2%自两侧檐口向中间找坡),1:2水泥沙浆找平层厚20mm,二毡三油防水层,撒绿豆沙保护。

门窗做法:门厅处为铝合金门窗,其他均为木门钢窗。

地质资料:三类建筑场地。

基本风压w0=0.55kn/m2,地面粗糙度属于B类。1)活荷载:屋顶活荷载2kn/m2,(不上人屋顶活荷载0.5kn/m2)办公楼楼面活荷载标准值2.0kn/m2,走廊.楼梯活荷载标准值2.5KN/m2。

设计第7榀横向框架,标准层建筑平面。

柱网平面布置如下图所示

柱的线刚度为

二、某四层办公楼混凝土框架结构设计计算书

1.结构平面布置

建筑平面图 建筑剖面图

边跨(AB CD跨)梁:取h=1/12*L=1/12*6000=500mm,取b=250mm。中跨(BC跨)梁:取h=400mm,b=250mm。

边柱(A轴D轴)连系梁,取b×h=250mm×500mm;中柱(B轴,C轴)连系梁,取b*h=250mm*400mm;柱截面均为b*h=300mm*450mm,现浇楼板厚100mm。

结构计算简图如图1。根据地质资料,确定基础顶面离室外地面为500mm,由此求得底层层高为 4.3m。各梁柱构件的线刚度经计算后列于图1.其中在求梁截面惯性矩时考虑到现浇楼板的作用,取I=2

I(I0为不考虑楼板翼缘作用的梁

截面惯矩)。

AB、CD跨梁:

i=2

E*1/12*0.25*0.50^3/6.0

c

=8.68*10^(-6)

E3m

c

BC跨梁:

i=2*

E*1/12*0.25*(0.4^3)/2.5=10.67*10^(-4) 3m

c

上部各层柱:

i=EC*1/12*0.30*(0.45^3)/3.2=7.12*10^(-4)

E3m

c

底层柱:

i=EC*1/12*0.3*(0.45^3)/4.3=5.30*10^(-4)

E3m

c 2.计算简图

结构平面布置图

结构计算简图

3.荷载计算

1)恒荷载

(1)屋面荷载

A

二毡三油防水层0.35kn/m2

20厚1:2水泥沙浆找平0.02×20=0.4kn/m2

100厚~140厚(2/100找坡)膨胀珍珠岩(0.1+0.14)/2×7=0.84kn/m2

100厚现浇钢筋混凝土楼板0.10×25=2.5 kn/m2

15厚纸筋灰抹底0.015×16=0.24kn/m2

合计4.33kn/m2

边跨(AB CD)框架梁自重

0.25×0.50×25=3.13 kn/m

梁侧粉刷2×

(0.5-0.1)×0.02×17=0.27 kn/m

中跨(BC)框架梁自重

0.25×0.4×25=2.5 kn/m

梁侧粉刷

2*(0.4-0.1)*0.02*17=0.2kN/m

因此作用在屋顶框架梁上的线荷载为:

g =g4cd1=3.4 kn/m

4ab1

=2.7 kn/m

4bc1

g4

=g4cd2=4.33×3.9=16.89 kn/m

ab2

=10.83 kn/m

4bc2

B

楼面框架梁线荷载标准值

20厚水泥沙浆面层

0.025×20=0.50 kn/m2

100厚现浇钢筋混凝土楼板

0.10×25=2.5 kn/m2

20厚纸筋灰石灰抹面

0.15×16=0.24 kn/m2

楼面荷载3.24 kn/m2

边跨框架梁及梁侧粉刷

3.4 kn/m

边跨填充墙自重0.24

×(3.2-0.5)×19=12.31 kn/m

墙面粉刷

(3.2-0.5)×0.02×2×17=1.84 kn/m

边跨框架梁及梁侧粉刷

2.7 kn/m

因此作用在中间层框架上的线荷载为

g =g cd1=17.55 kn/m

ab1

=2.7 kn/m

bc1

g

=6.32kn/m

ab2

g

=12.64 kn/m

cd2

bc2=8.1 kn/m

C

屋面框架节点集中荷载标准值

边跨连系梁自重0.25×0.5×3.9×25=12.19KN

梁侧粉刷0.02×(0.50-0.10)×2×3.9×17=1.06 KN

1米高女儿墙自重1×3.9×0.24×19=17.78KN

墙侧粉刷1×0.02×3.9×7=2.65KN

连系梁传来屋面自重0.5×3.9×0.5×3.9×3.98=15.13KN

顶层边节点集中荷载G4A=G4D=48.81KN

中柱连系梁自重0.25×0.40×3.9×25=9.75KN

梁侧粉刷0.02×(0.4-0.1)×2×3.9×17=0.80KN

连系梁传来屋面自重0.5×(3.9+3.9-2.5)×1.25×3.98=13.18KN

0.5×3.9×1.95×3.98=15.13KN

顶点中节点集中荷载G4B=G4C=38.86KN

D

楼面框架节点集中荷载标准值

边柱连系梁自重12.19KN

粉刷1.06KN

钢窗自重2.43KN

窗下墙体自重14.77KN

粉刷2×0.02×0.9×3.6×17=2.20KN

窗边墙体自重0.60*(3.2-1.4)*0.24*19 =4.92kN

粉刷0.73KN

框架柱自重0.3×0.45×3.2×25=10.8KN

粉刷0.78×0.02×3.2×17=0.85 KN

连系梁传来楼面自重

0.5×3.9×0.5×3.9×3.24=12.32KN

中间层边节点集中荷载G A=G D=62.27KN

中柱连系梁自重9.75KN

粉刷0.80KN

内纵墙自重3.6×(3.2-0.4)×0.24×19=45.96KN

粉刷3.6×(3.2-0.4)×2×0.02×17=6.85KN

扣除门洞重-2.1×1.0×(5.24-0.2)=-10.58KN

框架柱自重10.8KN

粉刷0.85KN

连系梁传来楼面自重10.73KN

12.32KN

中间层中节点集中荷载

G B=G C=87.48KN

恒荷载作用下的结构计算简图()

2)活荷载计算

活荷载作用下的结构计算简图如图()图中各荷载计算如下

P4AB =P4CD=0.5×3.9=1.95KN/m

P4BC=0.5×2.5=1.25 KN/m

P4A=P4D=0.5*3.9*0.5*3.9*0.5=1.90 KN

P4B=P4C=0.5*(3.9+3.9-2.5)*1.25*0.5+0.25*3.9*

3.9*0.5=3.56 KN

P AB =P CD =2.0×3.9=7.8 KN/m P BC =2.5×2.5=6.25 KN/m

PA=PD=0.25×3.9×6.0×2.0=8.7 KN PB=PC=14.79 KN

3)风荷载

风荷载标准值计算公式

因为高度小于30米,可取 =1.0;对于矩形截面 =1.3; 可查荷载规范当查得的 〈1.0 时,取 =1.0,将风荷载换算成作用在框架上的集中荷载计算结果如图所示

w w r z s z k μμμβ=z βs μz μz

μz

μ

层次

?s Z/m

Ws A/ m 2 Pw/ KN

4 1.0 1.3 13.4 1.10 0.5

5 10.14 9.64 3 1.0 1.3

10.2

1.01 0.55 1

2.48 8.92

2 1.0 1.

3 7.0 1.00 0.55 12.48 8.92 1 1.0 1.3 3.8 1.00 0.55 13.65 9.76

4.内力分析

z

μs

μz

β

(1)恒荷载作用下的内力计算

恒荷载作用下的风力计算采用分层法

取出顶层进行分析结构计算如图图中框架刚度取框架柱实际刚度的0.9倍。

图中梁上分布荷载由三角形和梯形两部分组成;根据固端弯矩相等的原则,先将梯形分布荷载及三角形分布荷载化为等效均布荷载计算公式如下图所示

把梯形荷载化为等效均布荷载

G4边=g4ab1+(1-2x2+x3)g4ab2=17.3 KN/m

G4中=g4bc1+5/8g4bc2=18.28kn/m

结构内力可用弯矩分配法计算并可利用结构对称性取1/2结构计算各杆件的固端弯矩为

M4AB=51.9 KN.m

M4bc=9.52 KN.m

M4CB=4.76 KN.m

1)顶层在恒荷载作用下的弯矩图:

2)标准层在恒荷载作用下的弯矩图:

3)底层在恒荷载作用下的弯矩图:

4)恒荷载作用下的弯矩总图:

5)恒载作用下的剪力轴力图:

高层办公楼设计设计总说明

设计总说明 一、设计依据 依据现行国家规定、规范及标准: 《民用建筑设计通则》(GB 50352-2005) 《高层民用建筑设计防火规范》(GB 50016-2006) 《混凝土结构设计规范》(GB 50010—2010) 《高层建筑混凝土结构技术规程》(JGJ 3-2010) 《建筑抗震设计规范》(GB 50011-2010) 《建筑结构荷载规范》(GB 50009-2012) 《建筑地基基础设计规范》(GB 50007—2011) 《建筑桩基技术规范》(JGJ 94-2008) 《房屋建筑制图统一标准》(GB 50001—2010) 二、工程概况 本设计为在广东汕头的某高层办公楼,包括建筑设计与结构设计。该建筑为地下1层,地上20层,其建筑用途为商场与办公楼,地下一层为停车库,地上二层为大型商场,上面十八层为办公楼。建筑主屋面高度为81米。用地面积为7000平方米,总建筑面积为39210、84平方米,容积率为5、18;建筑占地面积为2621、34平方米,建筑密度为37、71%;绿化面积为2130、11平方米,绿化率为30、43%;地上有20个停车位,地下车库有54个停车位。另外,该地区的地震设防烈度为8度 (0、2g),采用框架-剪力墙结构,剪力墙与框架部分的抗震等级均为一级。 三、建筑设计 建筑设计就是在总体规划的前提下,根据设计任务书的要求,综合考虑基地环境、使用功能、综合选型、施工、材料、建筑设备、建筑艺术及经济等因素,建筑体型设计成就矩形,不但满足建筑面积与采光要求的需要,而且外形朴素大方。在正南方设置商场主入口,在正西方向设置次入口。办公楼与商场入口分开设计,保证人群分流,避免造成交通拥挤与混乱。在交通联系方面,办公主楼设有6部2、4mX2、4m的电梯,其中2部位消防电梯,并设有2部消防楼梯。商用裙房部分设有四部消防楼梯,并设有1部自动扶梯。 1、墙体做法 1、1裙房、办公楼内墙面(200mm厚): 做法:1)、加气混凝土砌块 2).水泥粉刷墙面2度 1、2外墙面(200mm厚):

某框架结构办公楼建筑结构施工图识读与基本构件计算土木设计说明

学院 毕业实训(设计) 计算书 题目:某框架结构办公楼 建筑结构施工图识读及基本构件计算二级学院:建筑工程学院 2013年01月10日

2013 届建筑工程技术专业毕业设计某框架结构办公楼 设 计 和 计 算 任 务 书 学院建筑工程学院 二〇一二年十月 某框架结构办公楼设计和计算任务书

一.目的要求 要求掌握读图识图的基本原理、方法与步骤。主要目的是使学生全面巩固、掌握读 图和识图的能力,不仅能读懂看懂,而且更能用已掌握的知识去解释、分析实际工程图纸,发挥出学生的主动积极性,培养学生的创新思维能力。 通过一个实例工程的结构设计训练,要求学生初步掌握结构设计训练的一般原则、 步骤和方法,能综合运用已学过的知识,培养综合分析问题、解决问题的能力,以及相应的设计训练技巧,同时还将培养设计训练工作中实事、严谨、准确的科学态度和工作作风。初步掌握多层建筑的结构选型、结构布置、结构设计及结构施工绘图的全过程,从而使学生学会具有一定的建筑结构的设计能力。 二.设计和计算的容 1.概况 本工程为某中等专业学校迁建工程之一的行政楼,建筑层数为四层,框架结构,整 体现浇。总占地面积738.3m ,总建筑面积2941.2 m 2 。。建筑高度:17.55m ,局部楼梯间高20.55m 。建筑耐久年限为50年。工程耐火等级为二级。工程屋面防水等级:为Ⅱ级,砼雨蓬为Ⅲ级。工程设计标高室±0.000相当于黄海高程79.45m,室外高差0.45m 。 建筑结构的安全等级为二级,地基基础设计等级为丙级。设计使用年限为 50年,耐火等级为三级。 依据的岩土工程勘察报告,场地较为平整,自上而下,土层岩性依次为耕植土、粉 质粘土、卵石、基岩。建筑场地等级为二级,基础持力层下无软弱夹层存在,场地稳定性较好。岩土工程勘察报告建议以卵石层位基础持力层。场地地下水类型简单,为第四系空隙性潜水。受大气降水及侧向渗流补给。地下水水位埋深在3.0~3.70米之间。本场地地下水对建筑材料无腐蚀性。 三.结构说明 工程设计墙、梁、板砼等级为C25,柱砼等级为C30,基础砼等级为C15,钢筋选用 一级钢HPB300,二级钢筋HRB335。受力钢筋混凝土保护层厚度为:板15mm ,梁25mm ,基础梁40mm ,柱30mm ,屋面板:外侧20mm ,侧15mm 。 箍筋必须为封闭式,非焊接箍筋的末端应做成135°弯钩,弯钩端头平直段长度不 应小于5d 。砌体工程:本工程±0.000以下墙体采用水泥实心砖,砖强度等级不小于 Mu15.0,水泥砂浆强度等级M10。本工程±0.000以上墙体外墙采用KP1多孔,砖强度 等级Mu10.0,用M7.5混合砂浆砌筑。墙采轻质墙体材料,要求容重不大于3/9m kN , 轻质隔墙做法及构造要求参照省建筑标准图集《MS 型煤渣混凝土空心砖结构构造》(2005浙G31)或行业及厂家相关标准。 四.设计依据 《建筑结构可靠度设计统一标准》 (GB50068-2001)

某城市政府机关办公大楼工程结构设计

某城市政府机关办公大楼工程结构设计 通过洛阳市某政府机关办公共大楼的结构设计,对高层框架——剪力墙结构的基础方案选取、结构计算、设计构造等方面进行了讨论,并提出了设计中的一些体会和建议。 标签:结构设计;筏板基础;框架—剪力墙 1 工程概况 办公大楼建筑总高84.30米,总长180.3米(高层主体长130.2米,宽22.8米),总建筑面积62390平方米。大楼地上21层,其中一层为架空停车场,可停车126辆,二层为入口大厅,三层以上为政府办公用房。群楼为会议用房,设400人大型报告厅2个,200人会议厅2个,容纳80人的电视电话会议厅和200平方米的贵宾接待厅各一个。大楼设地下室一层,为后勤服务及设备用房。大楼二层及标准层平面图见图一、图二。 2 地基基础设计 场地工程地质条件: 根据岩土工程勘察报告,场地地形基本平坦,相对高差1.20米,场地地貌为洛河一级阶地。建筑场地类别为Ⅱ类,场地特征周期为0.35s。建设场地及附近地段不存在全新活动断裂带及滑坡、崩塌、泥石流、震陷等不良地质作用,场地地基也不存在地震液化土层,场地稳定,适宜建筑。 场地表层为耕土及杂填土,下部土层自上而下分为: 黄土状粉土及黄土状粉质粘土,可塑,为新近堆积土,具中-高压缩性,偶具湿陷性,层厚2.5-5.1米,层面埋深0.2-1.5米。 卵石及中粗砂,稍湿,稍密。卵石次圆状、次棱角状,直径3-5cm,含量50-60%,有泥沙填充,厚0-2.6m,呈透镜体状,主要分布在场区中部;中粗砂浑圆中等,较为均一,厚0-1.2m,呈透镜体状,主要分布在场区东部。该层层面埋深2.8-5.6米。 卵石,呈次圆状、次棱角状,分选中等,直径一般3-7cm,含量60-80%,有沙砾填充,稍密-中密,在场地内均匀分布,本层含水透水,层面埋深3.8-5.6

钢结构课程设计

中南大学 《钢结构基本原理》 课程设计 设计名称:钢框架主次梁设计 专业班级:土木1112班 姓名:周世超 学号: 指导老师:龚永智 设计任务书 (一)、设计题目 某钢平台结构(布置及)设计。 (二)、设计规范及参考书籍 1、规范 (1)中华人民共和国建设部. 建筑结构制图标准[S](GB/T50105-2001) (2)中华人民共和国建设部. 房屋建筑制图统一标准[S](GB/T50001-2001) (3)中华人民共和国建设部. 建筑结构荷载规范[S](GB5009-2001)(4)中华人民共和国建设部. 钢结构设计规范[S](GB50017-2003)(5)中华人民共和国建设部. 钢结构工程施工质量验收规范[S](GB50205-2001) 2、参考书籍

(1)沈祖炎等. 钢结构基本原理[M]. 中国建筑工业出版社,2006 (2)毛德培. 钢结构[M]. 中国铁道出版社,1999 (3)陈绍藩. 钢结构[M]. 中国建筑工业出版社,2003 (4)李星荣等. 钢结构连接节点设计手册(第二版)[M]. 中国建筑工业出版社,2005 (5)包头钢铁设计研究院?中国钢结构协会房屋建筑钢结构协. 钢结构设计与计算(第二版)[M]. 机械工业出版社,2006 (三)、设计内容 某多层图书馆二楼书库楼面结构布置示意图如图一所示,结构采用横向框架承重,楼面板为120mm厚的单向实心钢筋混凝土板。荷载的传力途径为:楼面板—次梁—主梁—柱—基础,设计中仅考虑竖向荷载与动荷载的作用。框架按照连续梁计算,次梁按照简支梁计算。其中框架柱为焊接H型钢,截面尺寸为H600X300X12X18,楼层层高取3.9米 采用的钢材为Q345,焊条为E50 柱网尺寸9 ×9,永久荷载5,活荷载10 活荷载分项系数为1.4 恒荷载分项系数为1.2 (四)、设计内容要求 1)验算焊接H型钢框架柱的承载能力,如不满足请自行调整 2)设计次梁截面CL-1(热轧H型钢)。 3)设计框架主梁截面KL-1(焊接工字钢)。 4)设计框架主梁短梁段与框架柱连接节点,要求采用焊缝连接,短

办公楼设计开题报告47935

毕业设计(论文) 开题报告 题目西安建筑设计院办公楼设计 专业土木工程专业 班级 学生 指导教师 2017年 一、毕业设计(论文)课题来源、类型 毕业设计我选到的课题是西安建筑设计院办公楼设计,来源于老师的命题

与工程实际。课题类型属于办公楼设计范畴,要求我在导师的指导下,通过查阅相关国家标准及规范运用所学知识系统独立的完成此设计,解决课题内的问题,熟悉相关标准规范。实践性强、综合性大。 二、选题的目的及意义 通过此办公楼设计,我会综合性地运用大学四年内所学到的理论去分析问题、解决问题。在设计的过程中,我要将已有知识进行梳理和应用,它既是一次尝试,也是一次锻炼。毕业设计还能让我更好的认识目前房建行业的现状,更好的对自己定位,认知自己。将自己的知识与实践结合,为之后工作中的应用做个好的开头。 毕业设计是我们对自己能否把所学的基础理论和专业知识,转化为解决实际问题能力的一次全面检验,是对自己大学学习成果的综合考核,也是引导我走向实际工作岗位的桥梁。毕业设计中我能基本了解、简单掌握从事此类建筑工程工作的一般步骤和基本方法,使自己在习惯、见识和能力等诸多方面都得到些许训练、转化及提高,也为后续的工作学习打下一份良好坚实的基础。因此,搞好毕业设计,对于自己整体素质的提升意义匪浅,对自己综合能力的提高重要非凡。 本次我选择办公综合楼作为毕业设计课题,不仅仅是因为办公楼在今后城市发展中具有重要地位,更为重要的是它的人性化让我对这个行业有了较大的兴趣和信心,进一步加大了我投入建筑设计的积极性。同时,毕业设计还可以使我进一步熟悉建筑空间环境组合设计和构造设计的基本原理和方法,具备一般工业与民用建筑设计的基本能能够根据不同情况,合理的选择结构,构造方案的能力。能熟练的进行结构计算,较好的掌握计算机在建筑和结构设计计算中的应用,学会利用各种设计资料。在规定的时间内完成设计的所有内容,包括建筑部分跟结构部分的设计图与设计计算书。能使自己了解一些必要的规范,熟练应用CAD和PKPM等必要软件。 也通过毕业设计的实践,使我能够深刻理解多层框架结构的受力性能、变形特点和设计原则。掌握框架结构体系的布置特点,计算简图的确定方法;掌握风荷载及地震作用的计算方法、框架结构内力与位移计算的实用方法;掌握现浇多层框架结构的抗震概念设计,框架的截面设计原理、抗震构造要求及地基基础的设计方法。熟练阅读工程地质报告,熟悉施工图的内容、工作步骤及表达方法,培养自己综合运用专业知识来分析和解决实际工程问题的能力。 三、本课题在国内外的研究状况及发展趋势 本课题为办公楼设计,采用钢筋混凝土框架结构。钢筋混凝土框架结构的

钢筋混凝土结构课程设计模板

网络教育学院 《钢筋混凝土结构课程设计》 题目:海天厂房单向板设计 学习中心:浙江电大仙居学院奥鹏学习中心[22] 专业:土木工程 年级: 2012 年春季 学号: 学生:张奇 指导教师:

1 基本情况 本章需简单介绍课程设计的内容,包括厂房的尺寸,板的布置情况等等内容。 一、设计资料 海天多层厂房为多层内框架结构,一层平面如图所示,露面周边支撑于外墙,采用现浇钢筋混凝土单向板,烧结承重多孔砖砌体承重外墙,钢筋混凝土内柱尺寸为400×400㎜。 1.楼面做法 20厚水泥砂浆地面,钢筋混凝土现浇板,20厚混合砂浆抹底。 2.荷载 楼面等效均布活荷载标准值为7KN/㎡,水泥砂浆容重为20KN/㎡,混合砂浆容重为17KN/㎡,钢筋混凝土容重为25KN/㎡. 永久荷载的分项系数按照永久荷载效应控制的组合,取为;活荷载的分项系数为。 3.材料 混凝土楼板采用 C25,梁内受力钢筋为 HRB400级,板内钢筋及箍筋为 HPB235 级。 二、楼板结构平面布置及截面尺寸确定 主梁沿横向布置,次梁按纵向布置。 主梁的跨度为6M,次梁跨度为6M,主梁每跨内布置两根次梁,板的跨度为 2M,l 2/l 1 ==3 按照单向板设计。 按高跨比条件,要求板的厚度h≥2000×1/40=50㎜,对工业建筑的楼板要求h≥80㎜,取板厚为80㎜。 次梁截面高度要求h= l 0/18 ~l /12 =6000 /18 ~ 6000 /12= 333 ~ 500 ,考虑到 楼面的活荷载比较大,取h=450 mm .截面宽度取为b=200mm 。 主梁截面高度要求 h= l 0/15 ~l /10= 6000 /15 ~ 6000 /10 =400 ~ 600 mm ,取 h=600mm。截面宽度取为 b=300mm 。楼板的结构平面布置图见图2

三层框架结构办公楼工程施工设计方案

第一章编制依据 ⑴ XX公司提供的办公楼工程定点图; ⑵ XX公司提供的办公楼工程设计方案; ⑶ XX公司提供的办公楼工程地址勘察报告; ⑷ XX公司提供的办公楼工程技术措施和设计要点; ⑸国家现行的有关法规、规范、技术标准; 工程概况 本工程建筑名称为XXXX小区10#综合楼,建筑地点位于廊坊市光明东道以北,建设路以东。 本工程建筑主体为三层,建筑高度11.850m(室外地面到檐口的高度),建筑面积为3048。88㎡。 本工程建筑结构形式为框架结构,建筑结构的类别为丙类,合理使用年限50年,抗震设防烈度为8度。 主要设计参数及概况如下: (一)地基与基础 本工程基础形式采用天然地基上浅基础,砼标号为C35,基础垫层采用C20素混凝土。 基础部分墙体材料采用MU10粉煤灰砖,M10水泥砂浆砌筑,基础墙双面抹1:2水泥砂浆20mm厚,粉煤灰砖容重不大于22KN/㎡。 (二)主体结构工程 混凝土工程:柱、梁、板混凝土为C30。

砌体工程:±0.000以上的墙体采用加气混凝土砌块,M7.5混合砂浆砌筑,加气混凝土砌块容重不大于8KN/㎡。 (三)装饰工程 外墙采用乳胶漆墙面,内墙以水泥砂浆墙面为主,卫生间采用瓷砖墙面(有防水层)。 (四)门窗工程 1、所有外墙窗均为塑钢窗,5mm厚白色浮法玻璃(空气层厚度9mm)。 2、门窗立樘位置,图纸无特别标明时,窗及门均立墙中。直接对外窗均为中空玻窗并加装活动横百页,遮阳设施甲方自理。外窗的抗风压和气密性需达到6级,水密性需达到2级。 (五)节能工程 1.墙体保温材料为水泥发泡板,墙面保温厚度为90mm。 2.屋面保温材料为挤塑聚苯板,厚度为100mm。 (六)防水工程 1.墙基防潮:底层所有墙体均须进行防潮处理,未设钢筋混凝土自防水处做水泥砂浆。当室内地坪出现高差或室内地坪低于室外地坪时,不仅在两到地坪出的墙身内做两到水平防潮层,而且应对有高差部分的墙体做垂直防潮。 2.屋面防水等级为二级。防水层采用2mm厚SBS改性沥青防水卷材,其合理使用年限为15年。

办公楼建筑结构设计(毕业设计)

大连民族学院本科毕业设计 大连华兴集团办公楼建筑结构设计 学院(系):土木建筑工程学院 专业:土木工程 学生姓名:罗挺 学号: 2011111316 指导教师:赵天雁 评阅教师:徐蕾 完成日期: 2015年6月9日 大连民族学院

摘要 这次设计是按大连民族学院土木工程学院2015年毕业设计要求编写的毕业设计计算书。题目为“办公楼建筑结构设计”,该建筑是一个四层的框架结构房屋。结构形式为钢筋混凝土框架结构,底层层高为3.9m,其余各层层高为3.6m,室内外高差为0.45m。 设计内容包括建筑设计,结构设计等。建筑设计部分包括平面设计、立面设计、剖面设计及细部构造的设计等。除此之外,还运用了CAD和天正等来绘制办公楼的平面图、立面图和剖面图。结构设计则含了梁、柱截面尺寸确定,水平荷载和竖向荷载作用下结构的内力以及侧移的计算,内力组合和截面设计。然后,就是基础的设计。基础设计包含基础选型、基础板配筋计算等。在设计过程中,还运用了PKPM进行辅助计算,并拿电算与手算结果进行验算分析。最后,按照任务书要求编写了本计算书。 对于这个设计,本着安全、适用、经济和美观的要求,平面布局分区明确,流线合理,互不干扰。综合考虑了建筑物使用上的各种因素,从而解决了建筑物的外观造型、房间布置、配筋计算等很多关键问题。通过这次设计,将大学所学的全部专业知识做了一次很好的衔接,发现各个学科之间不是独立存在的,而是融会贯通的,算得上是一次对大学所学知识的全面检阅。 关键词:办公楼;框架结构;结构设计;柱下独立基础

The building structure design of office building of Dalian Huaxing Group Abstract This design is according to the Civil Engineering College of Dalian Nationalities University 2015 graduation design calculations prepared by the design requirements. The title is office building structure design, which is a four story frame structure.. Structure of reinforced concrete frame structure, the bottom storey 3.9m. The rest of each storey is 3.6m, indoor and outdoor elevation is 0.45m. The design includes architectural design and structure design.. Architectural design includes graphic design, facade design, profile design and detail structure design, etc. At the same time, drawing office building with CAD and it was software such as plan, elevation and profile. The structure design mainly includes the determination of the beam, the column section size, the internal force and the lateral displacement calculation, the internal force composition and the section design of the frame structure under the horizontal load and the vertical load.Then, basic design.. Basic design includes basic type selection, basic layout, foundation slab reinforcement calculation, etc.. In the design process, the computer aided calculation of PKPM can be carried out, and the calculation results are compared with the results of the calculation. Finally, the preparation of the statement in accordance with the requirements of the task book. For this design, in line with safety, application, economic and aesthetic requirements, the layout of the plane is clear, streamline and reasonable, not interfere with each other. Taking into account the various factors of the buildings, the key issues of building appearance, room layout and reinforcement calculation are resolved.. Through this design, University will learn professional knowledge of all do a good interface, between the various disciplines is no longer exist independently, but mastery, indeed considered is one of the knowledge of the comprehensive review. Keywords: Office Building, frame structure, structure design, column independent foundation

结构力学课程设计多层框架结构(DOC)

结构力学课程设计多层多跨框架结构内力计算 姓名: 班级: 学号: 任课教师: 日期:

多层多跨框架结构内力计算指导书 一. 任务 1. 求解多层多跨框架结构在竖向荷载作用下的弯矩。 2. 计算方法: (1)用近似法计算:手算竖向荷载作用下分层法计算; (2)最好用电算(结构力学求解器)进行复算。 (3) 最好对比手算与电算,就最大相对误差处,说明近似法产生误差的来源。 3. 将手算结果写成计算书形式。计算简图:如图(一)所示。 4. 基本计算参数 材料弹性模量:723.010/E kN m =? 竖向荷载: 恒载 21=21/g k N m ,22=17/g kN m 5 荷载分组: (1)只计算竖向恒载(见图二); 图一 图二 本组计算的结构其计算简图如图一所示,基本数据如下: 混凝土弹性模量:72 3.010/h E kN m =? 杆件尺寸:

m L 5.51= m L 7.22= m H 5.41= m H 6.32= 柱:底 层:25555b cm h ?=? 其它层:2 5050b cm h ?=? 梁:边 梁:2 4525b cm h ?=? 中间梁:2 3525b cm h ?=? 竖向均布恒载: 恒载: 2/211g m kN = 2 /172 g m kN =(见图二) 各杆件的线刚度: 12 3 h b I L EI i ?==,其中 边 梁:4 m 3 10 9.112 345 .025.01 -?=?= I m kN L EI i ?=-???= =103645 .53 109.17100.31 1 1 中间梁: 4 m 3 10 9.012 3 35 .025.02 -?=?= I m kN L EI i ?=-???= = 100007 .23 109.07100.32 2 2 底层柱: 4m 310 6.712 3 55 .055.03 -?=?= I ` m kN H EI i ?=-???= = 506675 .43 106.77100.31 33

四层框架办公楼结构设计计算书毕业设计

四层框架办公楼结构设计计算书毕业设计 目录 第一章设计任务及基本要求 (2) 1.1 设计原始资料 (2) 1.1.1 工程概况 (2) 1.1.2 设计条件 (2) 1.2 建筑设计任务及要求 (3) 1.3结构设计任务及要求 (4) 第二章建筑设计说明 (5) 2.1建筑平面设计 (5) 2.1.1建筑平面布置 (5) 2.1.2柱网布置 (6) 2.2剖面设计 (6) 2.2.1房间各部分高度 (6) 2.2.2屋面做法 (6) 2.2.3楼面做法 (7) 2.2.4 地面做法 (7) 2.2.5 墙体构造 (7) 2.3 立面设计 (8) 2.3.1 外墙面做法 (8) 第三章结构设计 (8) 3.1 结构方案的选择及结构布置 (8) 3.1.1 结构方案的确定 (8) 3.1.2 基础类型的确定 (8) 3.1.3 结构构件截面尺寸和材料的选择 (8) 3.1.4 结构计算简图 (11) 3.1.5 框架柱的线刚度计算 (12) 3.2 框架荷载计算 (13) 3.2.1 恒荷载计算 (13) 3.2.2 楼面活荷载计算 (17) 3.3 风荷载计算 (18) 3.3.1 风荷载标准值计算 (18) 3.3.2 风荷载作用下的位移验算 (20) 3.4 力计算 (22) 3.4.1 恒荷载作用下的力计算 (22)

3.4.2 活荷载作用下的力计算 (27) 3.4.3 风荷载作用下的力计算 (31) 3.5 力组合 (39) 3.5.1 一般规定 (39)

3.5.2 框架梁柱力组合 (42) 3.6 框架梁、柱截面设计 (74) 3.6.1 框架梁的截面设计 (74) 3.6.2 框架柱的截面设计 (81) 3.7 现浇板的结构设计 (91) 3.7.1 板的结构计算简图 (91) 3.7.2 楼面现浇板设计 (91) 3.8 楼梯设计 (97) 3.8.1 平面布置图 (97) 3.8.2 楼梯梯段斜板设计 (98) 3.8.3 平台板设计 (100) 3.8.4 平台梁设计 (102) 3.9 框架结构柱下基础设计 (103) 3.9.1 设计资料 (103) 3.9.2 基础设计 (104) 3.10 PKPM 力计算 (111) 总结 (122) 参考文献 (123) 致谢 (124) 附录任务书 毕业设计指导书 开题报告 文献综述 外文原文与翻译 实习报告

某办公楼建筑、结构设计说明书

某办公楼建筑、结构设计说明书 1. 设计基本资料 1.1初步设计资料 1.1.1工程名称 某单位办公楼。 1.1.2工程概况 建筑面积5322.24卅,建筑总高为23.2m,主体大楼为六层, 室内外高差为0.45m. 1.1.3温度 冬季取暖室外计算温度-8 C,夏季通风室外计算温度32 C, 最热月平均气温28 C,最冷月平均气温-0.8 C。 1.1.4相对风向 全年主导风向为东北风,夏季主导风向为南风,当地基本风压是0.4KPa ,地面粗糙度为B类。 1.1.5年降雨量 年降雨量为631mm。 1.1.6建筑标准

建筑等级II级;防火等级II级 1.1.7水文资料 土壤最大冻结深度为30cm ,最大积雪厚度25cm ,基本雪压 0.35KPa 。常年地下水位为-2.0m ,水质对混凝土无侵蚀作用。 1.1.8地质条件 该建筑场地地基土层主要有粉土、粉质粘土、细砂等,详见附录。场地类别为II类,可不考虑地震液化影响。 1.1.9材料使用 混凝土:梁柱板均使用C30混凝土。 钢筋:纵向受力钢筋采用热轧钢筋HRB335,其余采用热轧 钢筋HPB300。 墙体: a. 外纵墙采用240厚灰砂砖(18KN/m3 ),一侧墙体为水刷石墙面(0.5KN/ m2),一侧为20伽厚抹灰(17KN/卅)。 b. 内隔墙采用200厚蒸压粉煤灰加气砼砌块(5.5KN/m3 ), 两侧均为20mm 厚抹灰。 c. 卫生间隔墙采用200厚蒸压粉煤灰加气砼砌块 (5.5KN/m3 ),两侧贴瓷砖(0.5KN/ m )。 .. 3 __ d. 女儿墙采用240厚加气砼砌块(5.5KN/m )两侧均为200 厚抹灰,墙高900mm。

混凝土框架结构课程设计

温州大学瓯江学院WENZHOUUNIVERSITYOUJIANGCOLLEGE 《混凝土结构课程设计<二)》 专 业:土木工程 班 级:08土木工程本一 姓 名:王超 学 号:08207023219 指导教 师:张茂雨 日2018年6月10号

期: 混凝土框架结构课程设计 一.设计资料 某三层工业厂房,采用框架结构体系。框架混凝土柱截面尺寸边柱为500mm× 500mm,中柱600mm×600mm。楼盖为现浇钢筋混凝楼盖,其平面如图所示。<图示范围 内不考虑楼梯间)。厂房层高分别为4.5,4.2,4.2M。地面粗糙度类别为B类。

2/45

梁、柱混凝土强度等级为C20,E c=2.55×10=25.5× 4N/mm2 10 6KN/m2。框架梁惯性矩增大系数:边框架取1.5,中框架取2.0。RTCrpUDGiT 中框架梁的线刚度: 1 ib 6 =αbEIb/l=2.0××25.5×10 ×0.3×0.7 3/6.6=66.28× 10 3KN·m 2 5PCzVD7HxA 边框架梁的刚度: 2 ib 6×0.3×0.7 αb EIb/l=1.5××25.5×10 3/6.6=49.70× 10 3KN·m 2 jLBHrnAILg 底层中柱的线刚度: i 6 底中=EI c/l=×25.5×10×0.6×0.6 3/4.5=61.44×103KN·m2 底层边柱的线刚度 i 底边=EI c/l=×25.5×106×0.5×0.5/4.5=29.51×103KN·m 6×0.5×0.5/4.5=29.51×103KN·m 2

某五层办公楼结构设计

某公司办公楼设计 摘要 本设计研究的内容是xx公司办公楼。采用框架结构,主体结构为五层,主楼标高18.55m,总建筑面积4000.36m2。在设计中楼﹑屋盖均采用现浇钢筋混凝土结构。本设计贯彻“实用、安全、经济、美观”的设计原则。按照建筑设计规范,认真考虑影响设计的各项因素。严格遵循相关的专业规范的要求,参考相关资料和有关最新的国家标准规范,对设计的各个环节进行综合全面的科学性考虑。 本设计主要包括建筑设计部分和结构设计部分。建筑设计部分主要包括建筑平面、立面、剖面的设计;结构设计方面包括了结构的布置、结构构件的配筋设计,具体有柱梁板设计、楼梯间计算、内力组合、框架配筋等方面。在确定框架布局之后,计算竖向荷载作用下的结构内力和水平荷载作用下的结构内力。进行内力组合找出最不利的一组或几组内力组合。选取最安全的结果计算配筋并绘图。 最后,使用专业软件和办公软件工具进行电脑输入,对手算的结果进行了分析和检查。最后依据计算结果,结合相应的结构构造要求,绘制结构施工图和建筑施工图,写出相应的设计说明以及结构设计计算书。 关键词:框架结构;抗震;结构设计;内力计算

Design of the Office Building of Xi'an Dinuo Pharmaceutical Co Ltd Abstract The design of the study content is xx company office building. Using frame structure, the main structure is divided into five layers, the elevation of 18.55m, the total construction area of 4000.36m2. In the design of the building, roof were using cast-in-place reinforced concrete structure. The design principle of "practical, safe, economic, beautiful" design. According to the architectural design standard, carefully consider the various factors affecting the design. Strict compliance with the relevant professional standard, reference to relevant information and the latest national standards, is a comprehensive scientific considerations on all aspects of the design. The design includes architectural design and structural design part. The design mainly includes building plane, elevation, section; structural design includes the reinforcement design of structural arrangement, structural components, specifically the column beam plate design, staircase, the combination of internal force calculation, the framework reinforcement etc.. In determining the distribution framework, internal force calculation of the structure internal force and the horizontal load function structure under vertical loads. Find a group or several groups of internal force combination of the most unfavorable combination of internal forces. Select the best safety results of the reinforcement and drawing. Finally, the use of professional software and office software tools for computer input, the opponent is the results of the analysis and examination. Finally, according to the calculation results, the corresponding structural requirements, drawing construction drawing and construction drawing design, write the corresponding and structure design calculations. Key Words:Frame structure; seismic; structural design; internal force calculation

某四层办公楼结构设计混凝土框架结构课程设计7380300

某四层办公楼结构设计混凝土框架结构课程设计7380300

建筑工程学院 混凝土结构课程设计项目名称:某四层办公楼结构设计

目录 一.设计任务书----------------------------------------------------(1)二.结构计算书----------------------------------------------------(2) 1.结构布置--------------------------------------------------(2) 2.计算简图--------------------------------------------------(2) 3.荷载计算-------------------------------------------------(3) (1)恒荷载------------------------------------------------(3) (2)活荷载------------------------------------------------(5) (3)风荷载------------------------------------------------(6) 4.内力分析--------------------------------------------------(7) (1)恒荷载作用下的内力计算------------------------(7) (2)活荷载作用下的内力计算------------------------(10) (3)风荷载作用下的内力计算------------------------(14) 5.内力组合--------------------------------------------------(16) 6.截面设计--------------------------------------------------(17) (1)梁的设计--------------------------------------------(24) (2)柱的设计--------------------------------------------(26)三.设计图纸 (一)梁柱配筋施工图-------------------------------------------(29)(二)各截面配筋详图-------------------------------------------(30)附:柱钢筋表-------------------------------------------------------(31)梁钢筋表-------------------------------------------------------(31)附录-------------------------------------------------------------------(32)致谢-------------------------------------------------------------------(33)

办公楼毕业设计开题报告|办公楼结构设计开题报告范文

设计(或研究)的依据与意义 本工程为某城区办公楼采用多层框架结构,为永久性建筑。该楼总建筑面积为8000㎡,拟建位置另行给定,抗震设防烈度为8度。 根据城市城市规划.建筑规模和要求以及现有的气象条件(气温.相对湿度.主导风向.基本雪压).工程场地地质条件.及材料供应和施工条件进行设计。西城区办公楼由主楼和会议中心两部分组成,主体结构为7层,内外装修均为一般装修。 相关设计依据 (1).《建筑地基设计规范》 gb50007-XX (2).《混凝土结构设计规范》 gb500010-XX (3).《建筑结构荷载规范》 gb50009-XX (4)、《建筑抗震设计规范》 gb500011-XX (5).《砌体结构设计规范》 gb50003-XX (6).《房屋建筑制图统一标准》 cb/t50001-XX (7).《建筑结构制图标准》、 gb/t50105-XX (8).《建筑设计防火规范》 gb50045-1995 (9).有关标准图集、相关教科书和及相关规定。 意义 近年来框架结构在世界各地又有了很大的发展,许多城市普遍兴建了包括商场、住宅、旅馆、办公楼和多功能建筑等各种类型的框架建筑。土木工程专业学生毕业后参加或从事框架结构设计已成为必须面对的现实之一。 通过毕业设计对大学期间所学的知识做一个系统的总结和应用,通过自己对在熟悉任务书的基础上参观、比较同类建筑,查阅、搜集有关设计资料使我的所学的知识得以综合的应用,提高综合知识的应用能力,对所学过的知识得以系统的深化。并培养我独立解决建筑设计、结构设计的内容和步骤,及掌握建筑施工图结构施工图绘制的方法,为今后工作打下良好的基础。 同时毕业设计是学生在毕业前半年的最后学习和综合训练的实践性学习环节,是学习深

4层行政办公楼毕业设计-行政办公楼毕业设计

职业技术学院办公楼框架结构设计 摘要 本设计为职业技术学院教学办公楼结构设计,四层框架结构。本地区抗震设防烈度为7度,场地类别为二类场地,基本风压为2 kN m。楼﹑屋 0.60/ 0.30/ kN m,基本雪压为2 盖均为现浇钢筋混凝土结构。 本设计贯彻“安全、适用、经济、美观”的设计原则。按照建筑设计规范,认真考虑了影响设计的各项因素。 本设计选取了结构方案中的一榀横向框架进行设计。先进行层间荷载代表值的计算,接着利用顶点位移法求出自震周期,进而按底部剪力法计算水平地震荷载作用下大小,同时计算出结构在风荷载作用下的荷载大小,进而求出在水平荷载作用下的结构内力(弯矩、剪力、轴力)。接着计算竖向荷载(恒载及活荷载)作用下的结构内力。找出最不利的一组或几组内力组合。选取最安全的结果计算配筋并绘图。此外还进行了结构方案中的室内楼梯的设计,完成了平台板,梯段板,平台梁等构件的内力和配筋计算及施工图绘制。 整个设计过程中,严格遵循相关的专业规范,参考相关资料和有关最新的国家标准图集,对设计的各个环节进行综合全面科学的考虑。总之,安全、实用、经济、美观是本设计的原则。设计计算整个过程中综合考虑了抗震要求、技术经济指标和施工工业化的要求。关键词:建筑设计,框架结构;抗震设计;荷载统计;内力组合

Abstract V ocational school building, using this as a four-story frame structure design, architectural layers. This region seismic intensity of 7 degrees, site category type venue, the basic wind pressure, the basic snow pressure. Floors, roofs using cast in-situ reinforced concrete structure. This design is to achieve "safe, practical, economic, aesthetic" design principles. According to the building design standards, carefully consider various factors designs. This design choice lateral framework program design. Between the first layer and the layer load calculation, it means that the value of using vertex displacement method, and then cut from the bottom of the seismic cycle method to calculate the size of horizontal seismic load, wind load and calculate the structure, and then find loads of load level structural forces (bending moment, shear force and the axial force) in size. Then calculate the vertical load (dead load and live load) under the action of the force structure. Identify the most unfavorable force of a group or several groups of combinations. Select the security reinforcement and calculated results animated addition to an indoor staircase structure design, complete flat bed board, bench boards, platforms beam forces and reinforcement calculation and construction drawings and other components. \ Throughout the design process, in strict compliance with the relevant professional regulations, refer to the relevant materials and the latest national standards related to all aspects of Atlas design, integrated comprehensive scientific considerations. In short, safe, practical, economic, aesthetic design principles. The whole process of design calculations considering seismic requirements, technical and economic indicators and industrialized construction requirements. Keywords: Architectural design ;Frame structure; Seismic design; Load statistics; Endogenic force combination

相关主题
文本预览
相关文档 最新文档