FUSE_选用
- 格式:pdf
- 大小:208.45 KB
- 文档页数:1
SELECTION FUSE
Information
1. Working Current= 1.9A
2. Inrush Current = 40A
3. Use work Temperature=
70℃
3216TD TEMPERAYURE DERATING CURVE
(1) Rudimentary compute
Current Rating = Working Current / safety factor(de-rating 80%) / Temperature
70℃
Current Rating =
1.90A / 0.8 /0.92
Current Rating =
2.5815A
(2) Inrush Current compute
Fuse compute
Melting I ^ 2 * tfuse ≧ I ^ 2 * tpulse * Fp /0.92
Fp=4.5 (solid matrix fuse pulse factor)
1.Pulse I^2t=0.72*Ipeak^2*t0.5
Melting I^ 2 * tfuse ≧ I ^ 2 * tpulse *Fp /
0.92
Melting I^2 * tfuse ≧ 0.72 * Ipeak^2 * t0.5 * 4.5 /
0.92
Ipeak=40A
t0.5=0.2000mS
3216TD3-R
Melting I^2*tfuse=3.3
0.72 * Ipeak ^ 2 * t0.5 * 1.25 /
=
1.12696
I^2 *tfuse ≧ I^2 * tpulse * Fp/0.92
3.3>1.126957
合格FUSE
rating=1.1269/3.3=34%