CISPR14 Household Applicances

  • 格式:pdf
  • 大小:492.96 KB
  • 文档页数:9

下载文档原格式

  / 9
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

CISPR14

Electromagnetic compatibility-

requirements for household appliances,electric tools and similar

apparatus

Overview

CISPR14Introduction Main Tests involved Test System

Introduction

CISPR14-1

Emission

Latest edition:5.0released2005

Applies to the conduction and radiation of radio-frequency(RF)

disturbances from appliances whose main functions are performed by motors and switching or regulatory devices,unless the RF

energy is intentionally generated or intended for illumination

Covers such equipment as household electrical appliances,

electric tools,regulating controls employing semiconductor devices, motor-driven electro-medical apparatus,electric toys,automatic

dispensing machines and cinema or slide projectors.

Frequency range covered are from9KHz to400GHz

Mains terminal continuous disturbance voltage Frequency Range 150KHz to 30MHz

Need to use LISN,Eg.ENV216

Disturbance power

Frequency Range 30MHz to 300MHz

Absorbing clamp MDS21is needed

For automatic system,Guiderail and

guiderail controller is needed

Discontinuous disturbance terminal voltage Frequency Range 150KHz to 30MHz

CL55C Click analyser is needed

Disturbance Field (30–1000MHz)

Only applicable to toys

Main Test Involved

R&S ENV 216R&S MDS21CL55C

Test System

Basic Configuration

Test Receiver

ESU40for Up to40GHz Accessories

ENV216LISN up to16A or ENV42003-phase LISN100A

Switching panel is needed TS-RSP with RSP-EMI to switch between voltage and power disturbance measurement

Click analyser if needed

Art.Hand is needed for Handheld devices

MDS21absording clamp and guiderail

HL526Antenna R&S ESU40 R&S TS-RSP

Test System

System Overview Radiated Test Setup(Up to1GHz)

Test Receiver

ESU40R11.05

R11.03W12.03W13.03Antenna HL562

W14.03

RP1AP1CP1 Switch Unit

TS-RSP

Conducted Test Setup(150kHz–30MHz/30MHz–300MHz)

Test Receiver ESU40 Switch Unit

TS-RSP

R11.04

R11.13W12.04W13.04

Conducted

Transducer RP1AP4

System Overview

相关主题