AISE_FIM7e_ch10
- 格式:ppt
- 大小:130.50 KB
- 文档页数:38


SIM7600E-H 4G HATThe SIM7600E-H 4G HAT is a 4G/3G/2G communication and GNSS positioning module, which supports LTE CAT4 up to 150Mbps for downlink data transfer. it is pretty low power consumption.You can connect this 4G module with computer to surf the Internet, or attach it onto Raspberry Pi to enable functions like 4G high speed connection, wireless communication, making telephone call, sending SMS, global positioning, etc.Note: this is a region-specific module, please check the supported bands before placing order.●Raspberry Pi connectivity, compatible with Raspberry Pi Zero/Zero W/Zero WH/2B/3B/3B+●Supports dial-up, telephone call, SMS, MMS, mail, TCP, UDP, DTMF, HTTP, FTP, etc.●Supports GPS, BeiDou, Glonass, LBS base station positioning●Onboard USB interface, to test AT Commands, get GPS positioning data, and so on●Onboard CP2102 USB to UART converter, for serial debugging●Breakout UART control pins, to connect with host boards like Arduino/STM32●SIM card slot, supports 1.8V/3V SIM card●TF card slot for storing data like files, messages, etc.●Onboard audio jack and audio decoder for making telephone call●2x LED indicators, easy to monitor the working status●Onboard voltage translator, operating voltage can be configured to 3.3V or 5V via jumper●Baudrate: 300bps ~ 4Mbps (default: 115200bps)●Autobauding baudrate: 9600bps ~ 115200bps●Control via AT commands (3GPP TS 27.007, 27.005, and V.25TER command set)●Supports SIM application toolkit: SAT Class 3, GSM 11.14 Release 99, USAT●Comes with development resources and manual (examples for RaspberryPi/Arduino/STM32)1Note: Does not contain Raspberry PiCommunications SpecificationsGNSS Specifications●Receiver type⏹16-channel⏹C/A code2●Sensitivity⏹Tracking: -159 dBm (GPS) / -158 dBm (GLONASS) / TBD (BD)⏹Cold starts: -148 dBm●Time-To-First-Fix (open air)⏹Cold starts: <35s⏹Hot starts: <1s●Accuracy⏹Position: <2.5m CEP●SMS⏹Supported types: MT, MO, CB, Text, PDU⏹Storage: USIM card and ME (default)●Audio feature⏹Supports echo cancellation⏹Supports noise reduction●Power supply: 5V●Operating voltage: 5V/3.3V (configured via jumper)●Operating temperature: -30°C ~ 80°C●Storage temperature: -45°C ~ 90°C●Dimension: 56.21mm x 65.15mm31.SIM7600E-H2.CP2102 USB to UART converter3.NAU8810 audio decoder4.TXS0108EPWR voltage translator: translates 3.3V/5V into 1.8V5.MP2128DT power chip6.MP1482 power chip7.Raspberry Pi GPIO header: for connecting with Raspberry Pi8.SIM7600 control interface: for connecting with host boards like Arduino/STM329.SIM card slot: supports 1.8V/3V SIM card10.TF card slot: allows file/SMS/... storage11. 3.5mm earphone/mic jackB interface: for testing AT Commands, getting GPS positioning data, etc.B to UART interface: for serial debugging, or login to Raspberry Pi14.MAIN antenna connector15.AUX antenna connector16.GNSS antenna connector17.Power switchwork status indicator19.Power indicator20.Operating voltage selection jumper:VCCIO - 3.3V: set operating voltage as 3.3VVCCIO - 5V: set operating voltage as 5V421.UART selection jumper:A: access Raspberry Pi via USB to UARTB: control the SIM7600 by Raspberry PiC: control the SIM7600 via USB to UART5Overview (1)Features (1)1.Hardware configuration (7)1.1.Hardware configuration (7)2.GPRS Debugging ................................................................................................ 错误!未定义书签。
UNIS R9900-M路由器单板与光模块适配关系表Copyright © 2022 紫光恒越技术有限公司及其许可者版权所有,保留一切权利。
非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本文档内容的部分或全部,并不得以任何形式传播。
UNIS为紫光恒越技术有限公司的商标。
对于本手册中出现的其它公司的商标、产品标识及商品名称,由各自权利人拥有。
本文档中的信息可能变动,恕不另行通知。
本系列产品支持多种光模块或线缆,不同接口支持的光模块或线缆类型不同,具体请参见下表。
更多光模块或线缆属性信息,请参见《UNIS光模块手册》。
单板名称端口支持的光模块说明MIC-CLP4L-M-Z 1-4 SFP-FE-LX-SM1310-A-ZMIC-CQ1L-M-Z 1 QSFP-100G-ER4L-WDM1300-Z QSFP-100G-LR4L-WDM1300-Z QSFP-100G-LR4-WDM1300-Z QSFP-100G-SR4-MM850-Z QSFP-100G-SWDM4-MM850-ZMIC-CQ2L-M-Z 1-2 QSFP-100G-ER4L-WDM1300-Z QSFP-100G-LR4L-WDM1300-Z QSFP-100G-LR4-WDM1300-Z QSFP-100G-SR4-MM850-Z QSFP-100G-SWDM4-MM850-ZMIC-PSP4L-M-Z 1-4 SFP-2.5G-LX-SM1310-ZMIC-SP4L-M-Z 1-4 SFP-622M-LX-SM1310-Z SFP-FE-LX-SM1310-A-ZMIC-TCP8L-M-Z 1-8 SFP-622M-LX-SM1310-Z SFP-FE-LX-SM1310-A-Z SFP-GE-LX-SM1310-A-Z SFP-GE-SX-MM850-A-Z SFP-GE-T-ZMIC-XP10L-M-Z 1-10 SFP-XG-LH40-SM1550-Z SFP-XG-LX-SM1310-E-Z SFP-XG-SX-MM850-D-ZMIC-XP4L-M-Z 1-4 SFP-XG-LH40-SM1550-Z SFP-XG-LX-SM1310-E-Z SFP-XG-SX-MM850-D-Z1。
71 00 Series Data Center SwitchesDCS-7120T-4S DCS-7140T-4S DCS-7148SX DCS-7048T DCS-7124S DCS-7148SSwitches covered by this guide:© Copyright 2011 Arista Networks, Inc.Quick Start GuideArista PDOC-00010-03 : 7100 Series Quick Start GuideChapter 1 – Getting StartedStep 1Unpack and remove the device and the accessories from the shipping box. Please inspect the items for any shipping damage.All illustrations apply to each Arista switch covered by this guide unless stated otherwise.Step 2Review the hardware installation and safety instructions that appear in this guide. The switch supports 100-127V or 200-240V AC inputs at 50 or 60 Hz. You can connect to either AC power source.Step 3Identify the serial console and management Ethernet ports and understand cabling needs. You only need to connect one of the management Ethernet ports – the second port provides redundancy. The serial console and management Ethernet ports are shown below (Figure 1-1 and Figure 1-2).© Copyright 2011 Arista Networks, Inc.Figure 1-1: 7100S Management Connections 2Serial Management Port Serial Management Port Ethernet Management Ports Ethernet Management PortsSTATUS FAN PS2Figure 1-2: 7100T/7000T Management ConnectionsChapter 1 – Getting StartedStep 4Access the switch through the console. The accessory kit includes an RJ-45 to DB-9 adapter cable.The default console speed is 9600 baud.The default login username is ‘admin’ with no password set.The PC or Terminal Server should have the following settings:data•8bitsbitbaud •1stop•9600•No fl ow control •No parity bitsStep 5 (optional)Confi gure the switch for ssh access through the Management Port. User input is in bold.EOSAristalogin:adminlocalhostLast login: Fri Dec 14 13:17:13 on consoleEnter privileged Exec Mode.localhost>enableEnter Global Confi guration Mode.l ocalhost#configure terminalConfi gure one of the management interfaces to acquire an IP address using DHCP.localhost(config)#interface management 1localhost(config-if)#ip address 192.0.2.8/24(replace with the IP address assigned to the switch)Exit the confi guration mode.localhost(config-if)#endSave your confi g.localhost#copy running-config startup-configAlternate command to confi gure a static IP address for Management Port:localhost(config-if)#ip address 192.0.2.8 255.255.255.0Once the IP address for the management port has been confi gured, you can connect from a host as shownbelow:**************.2.8(replace with the IP address assigned to the switch)3Arista PDOC-00010-03 : 7100 Series Quick Start GuideChapter 1 – Getting StartedStep 6 (optional)Other confi guration changes you may want to consider:• hostname • ip name-server 192.0.2.1• ip domain-name • clock timezone America/Los_Angeles• interface management 2ip address 192.0.2.9/24• ntp server Please refer to the Arista Command Reference for a description of all supported commands.MTU Confi gurationThe default MTU confi guration is 9216 bytes on all interfaces supporting jumbo packets by default.© Copyright 2011 Arista Networks, Inc.4Chapter 2 – Important Saftey InstructionsThe following safety instructions and warnings apply to the installation and operation of this product.Statement 1001 – Read the installation instructions before connecting the system to the power source.Statement 1002 – To prevent the switch from overheating, do not operate it in an area with the ambienttemperature higher than 104ºF (40ºC).Statement 1005 – Installation of this equipment must comply with local and national electrical codes.If necessary, please consult with the appropriate regulatory agencies and inspectionauthorities to ensure compliance.Statement 1007 – Do not physically stack units on any other equipment.Statement 1009 – Never lift the chassis using handles on modules.Statement 1010 – This equipment must be grounded. Never defeat the ground conductor.Statement 1012 – When installing this equipment, connect the ground conductor fi rst.Statement 1015 – This unit may have more than one power supply connection. All power connectionsmust be removed to de-energize the unit.Statement 1020 – The power input plug-socket combination must be accessible at all times because itserves as the main disconnecting device.Statement 1025 – This unit requires overcurrent protection.Statement 1030 – Only qualifi ed personnel should install, service or replace this equipment.Statement 1035 – No user serviceable parts inside. Refer all servicing to qualifi ed service personnel.Statement 1040 – Ultimate disposal of this product should be handled according to all national laws andregulations.Statement 1050 – Class 1 Laser Product: This product has provisions to install Class 1 laser transceiversthat provides optical coupling to the communication network. Once a Class 1 laserproduct is installed, the equipment is a Class 1 Laser Product (Appareil à Laser de Classe1). The customer is responsible for selecting and installing the Class 1 laser transceiverand for insuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 60825, CSAE60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the la-ser transceiver have been installed. Do not install laser products whose class rating isgreater than 1. Refer to all safety instructions that accompanied the transceiver prior toinstallation. Only Class 1 laser devices, certifi ed for use in the country of installation bythe cognizant agency are to be utilized in this product.Statement 1055 – Do not stare into the laser beam.5Arista PDOC-00010-03 : 7100 Series Quick Start GuideChapter 3 – Rack MountingBefore you begin, verify that the following guidelines are met:• Clearance areas to the front and rear panels allow for unrestricted cabling• All front panel indicators can be easily read• The AC power cord can reach from the AC power outlet to the connector on the switch rear panel• Airfl ow around the switch and through the switch is unrestricted2-Post Rack MountUse four #8 Philips fl at head screws to attach the long side of the bracket to the switch in one of the threemounting positions (front-mounting, mid-mounting, or rear-mounting).Figure 3-1: Front-Mounting Position© Copyright 2011 Arista Networks, Inc.6Chapter 3 – Rack MountingFigure 3-2: Mid-Mounting PositionRear MountingFor the rear-mounting position, you can attach the mounting brackets to the rear of the switch.Next, use the mounting screws needed for your rack to attach the brackets to the rack.7Arista PDOC-00010-03 : 7100 Series Quick Start GuideChapter 3 – Rack Mounting4-Post Rack MountSome racks may not be suited for a 2-post mount. If that is the case, you should use the 4-post mounting kitincluded with the switch.The mounting procedure is shown below:Figure 3-3: 4-Post Rack Mount: Step 1© Copyright 2011 Arista Networks, Inc.8Figure 3-4: 4-Post Rack Mount: Step 2Figure 3-5: 4-Post Rack Mount: Step 3Chapter 3 – Rack MountingArista PDOC-00010-03 : 7100 Series Quick Start Guide9Chapter 3 – Rack MountingFigure 3-6: 4-Post Rack Mount: Step 4© Copyright 2011 Arista Networks, Inc.10Figure 4-1: 7100S Series System Indicators Figure 4-2: 7100T/7000T Series System IndicatorsChapter 4 – Status IndicatorsFront Panel System Status IndicatorsSystem Status LEDIndicator StatusBlinking Green System powering up.Green All power supplies and fans are good.Red A power supply or fan is missing or in a failed state.Fan Tray Status LEDIndicator StatusOff Fan inserted, but status is unknown.Green Fan is good.Red Fan not inserted or in a failed state.Power Supply Status LEDIndicator StatusOff Power supply inserted, but status is unknown.Green Power supply is good.Red Power supply not inserted or in a failed state.Arista PDOC-00010-03 : 7100 Series Quick Start Guide 11STATUS FAN PS 2Fan Tray Status LEDFan Tray Status LED System Status LEDSystem Status LED Power Supply Status LED Power Supply Status LEDAggregate Fan Status LED (7100T Only)Indicator StatusOff One or more fans are inserted, but the status is unknown.Green All fans are good.Red Fan tray not inserted or in a failed state.Chapter 4 – Status IndicatorsRear Panel System Status IndicatorsFan Tray Status LED on Rear PanelIndicator StatusOff Fan inserted, but status is unknown. Green Fan is good.Red Fan in a failed state.Figure 4-3: Fan Status LED on Rear Panel650W Power Supply Status LED on Rear PanelIndicator StatusOff No AC power to any power supply.Green Power supply operating normally.Amber AC loss to this power supply (in 1+1 mode).Blinking Green Power supply internal error. Re-insert the power supply.© Copyright 2011 Arista Networks, Inc.12Fan Status LEDArista PDOC-00010-03 : 7100 Series Quick Start GuideChapter 4 – Status IndicatorsRear Panel System Status Indicators760W Power Supply Status LED (OK) on Rear PanelIndicator StatusOff Power Supply is not providing power to the switch.Green Power Supply is providing power to the switch.Figure 4-5: 760W Power Supply LEDs on Rear Panel 13 760W Power Supply Alert LED on Rear PanelIndicator StatusOff Power Supply has no internal failure.Yellow Power Supply has experienced an internal failure.760W Power Supply ~ AC LED on Rear PanelIndicator StatusOff No AC power to this power supply.Green Power Supply is providing power to the switch.Power Supply Status LEDPower Supply Alert LEDPower Supply ~AC LEDChapter 4 – Status IndicatorsPort LEDs Port Status Indicators 7100SIndicator StatusOff Port link is down.Green Port link is up.Yellow Port link is disabled in software.Flashing Yellow Port failed diagnostics.Figure 4-6: 7124S Port LEDs 14Top Port IndicatorsBottom Port IndicatorsFigure 4-7: 7148S/SX Port LEDs© Copyright 2011 Arista Networks, Inc.Port IndicatorsTop Port Indicators Top Port Indicators Top Port IndicatorsTop Port IndicatorsBottom Port Indicators Bottom Port Indicators Bottom Port IndicatorsBottom Port Indicators222421233334353637383940182017194244414342444143Chapter 4 – Status IndicatorsPort LEDsPort Status Indicators (7000T/7100T)Indicator StatusOff Port link is down.Green Port link is up.Yellow Port link is disabled in software.Flashing Yellow Port failed diagnostics.Figure 4-8: 7048T-4S/7120T-4S 1/10G-BASE-T Port LEDs Arista PDOC-00010-03 : 7100 Series Quick Start Guide15Figure 4-9: 7140T-8S 1/10G-BASE-T Port LEDsFigure 4-10: 7048T-4S/7120T-4S SFP+ Port LEDs Figure 4-11: 7140T-8S SFP+ Port LEDsChapter 5 – Obtaining Technical AssistanceAny customer, partner, reseller or distributor holding a valid Arista Service Contract can obtain technicalsupport in one of the following ways:Email: **************************. This is the easiest way to create a new service request.Please include a detailed description of the problem and the output of “show tech-support”.Web: /en/support. A support case can be created via the support portal on our website. You may also download the most current software and documentation, as well as viewFAQs, Knowledge Base articles, Security Advisories, and Field Notices.Phone:866-476-0000 or 408-547-5502.© Copyright 2011 Arista Networks, Inc. All rights reserved.16© Copyright 2011 Arista Networks, Inc. The information contained herein is subject to change without notice. Arista Networks and the Arista logo are trademarks of Arista Networks, Inc. in the United States and other countries. Other product or service names may be trademarks or service marks of others. Support**************************408 547-5502 866 476-0000 Headquarters 5470 Great America Parkway Santa Clara, CA 95054 USA 408 547-5500Sales ************************408 547-5501 866 497-0000For more information, visit 。