电磁流量计操作指南说明书
- 格式:docx
- 大小:37.61 KB
- 文档页数:4
FMG920B-SS-VO-NPTFMG90B Series- 2 -FMG90B SeriesTechnical changes reserved- 3 -Table of contents page0 About this operating manual ...................................................................................... 4 1 Device description ..................................................................................................... 5 1.1 Delivery, unpacking and accessories ...................................................................... 5 1.2 Intended use............................................................................................................ 6 1.3 Exclusion of liability ................................................................................................. 6 2 Safety instructions ..................................................................................................... 7 3 Construction and function .......................................................................................... 8 4 Installation of FMG90B .............................................................................................. 9 4.1 Installation instructions ............................................................................................ 9 4.2 Assembly ............................................................................................................... 10 5 Electrical connection ................................................................................................ 11 5.1 Wirings .................................................................................................................. 12 6 Commissioning and measuring operation ............................................................... 13 6.1 Commissioning ...................................................................................................... 13 6.2 Switching on and off .............................................................................................. 13 6.3 Measuring operation .............................................................................................. 13 7 Maintenance and cleaning ....................................................................................... 14 8 Disassembly and disposal ....................................................................................... 15 9 Technical data ......................................................................................................... 16 9.1 Characteristics FMG90B ....................................................................................... 16 9.2 Materials table ....................................................................................................... 17 9.3 Pressure drop ........................................................................................................ 18 9.4 Dimensions (20)Copyright notice:The reproduction, distribution and utilization of this operating manual as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.About this operating manual Series FMG90B- 4 -0 About this operating manual• The operating manual is aimed at specialists and semi-skilled personnel.•Before each step, read through the relevant advice carefully and keep to the specified order.• Thoroughly read and understand the information in the section “Safety instructions”. If you have any problems or questions, please contact your supplier or contact us directly at:Tel: (203) 359-1660 e-mail:**************Hazard signs and other symbols used:WARNING! / CAUTION! Risk of injury!This sign indicates dangers that cause personal injuries that can lead to health defects or cause considerable damage to property.CAUTION! Electric current!This sign indicates dangers which could arise from handling of electric current.CAUTION! Material damage!This sign indicates actions which could lead to possible damage to material or environmental damage.ADHERE TO OPERATING MANUAL! NOTICE!This symbol indicates important notices, tips or information. NO DOMESTIC WASTE!The device must not be disposed of together with domestic waste.Pay attention to and comply withinformation that is marked with this symbol. Follow the specified instructions and steps.Adhere to the given order.❑ Check the specified points or notices.Reference to another section, document orsource. • Item.FMG90B Series Device descriptionTechnical changes reserved - 5 -1 Device descriptionThe FMG90B series from Omega is a flow sensor without moving parts. The measurement is performed using magnetic induction.The FMG90B is used for measuring or metering water and electrically conductive fluids. The compact design and independence from the intake and discharge sections allows the FMG90B to be used under a variety of conditions.Versions:The FMG90B is available in different inner diameters from 0.12 in to 0.98 in. Type plate:You can find the type plate on the back of the FMG90B. It contains the most important technical data.1.1 Delivery, unpacking and accessoriesAll units have been carefully checked for their operational reliability before shipment. ❒ Immediately after receipt, please check the outer packaging for damages or any signs ofimproper handling.❒ Report any possible damages to the forwarder and your responsible sales representative.In such a case, state a description of the defect, the type and the serial number of the device.Report any in-transit damage immediately. Damage reported at a later date shall not be recognized. Unpacking:Carefully unpack the unit to prevent any damage.Check the completeness of the delivery based on the delivery note. Scope of delivery:❒ 1x FMG90B according to the order data. ❒ 1x Operating manual.IMPORTANT!Use the type plate to check if the delivered unit corresponds to your order.In particular, for devices with electrical components, check to see if the correct power supply voltage is specified.Device descriptionFMG90B Series- 6 -Accessories:❒ Connection cable with molded M12x1 coupling socket. ❒ M12x1 coupling socket as component.1.2 Intended useThe magnetic inductive flow sensor FMG90B must only be used for measuring and metering liquids with a minimum conductivity of 20 μS/cm.WARNING! No safety component!The magnetic inductive flow sensor of the FMG90B series is no safety component in accordance with Directive 2006/42/EC (Machine Directive). Never use the FMG90B as a safety component.The operational safety of the device supplied is only guaranteed by intended use. The specified limits (♑ § 9 "Technical data") may under no circumstances be exceeded.Before installing the device, check that the wetted materials of the device are compatible with the media being used (♑ § 9 “Technical data”).Measuring tube empty (or partially filled). / Conductivity too low.The green LED may blink irregularly if the measuring tube of the FMG90B is empty or partially filled or if the conductivity of the fluid being used is too low. Random pulses will be present at the output, but they do not represent an actual flow.Ensure that the measuring tube of the FMG90B is always completely filled (♑ § 4.1 "Installation instructions").Ensure that the conductivity of the fluid is at least 20 μS/cm.1.3Exclusion of liabilityWe accept no liability for any damage or malfunctions resulting from incorrect installation, inappropriate use of the device or failure to follow the instructions in this operating manual.FMG90B Series Safety instructionsTechnical changes reserved - 7 -2Safety instructionsBefore you install the FMG90B, read through this operating manual carefully. If theinstructions contained within it are not followed, in particular the safety guidelines, this couldresult in danger for people, the environment, and the device and the system it is connected to.The FMG90B corresponds to the state-of-the-art technology. This concerns the accuracy, the operating mode and the safe operation of the device.In order to guarantee that the device operates safely, the operator must act competently andbe conscious of safety issues.OMEGA provides support for the use of its products either personally or via relevant literature. The customer verifies that our product is fit for purpose based on our technical information. The customer performs customer- and application-specific tests to ensure that the product is suitable for the intended use. With this verification all hazards and risks aretransferred to our customers; our warranty is not valid. Qualified personnel:The personnel who are charged for the installation, operation and maintenance of theFMG90B must hold a relevant qualification. This can be based on training or relevanttuition.The personnel must be aware of this operating manual and have access to it at all times.The electrical connection should only be carried out by a fully qualified electrician. General safety instructions:In all work, the existing national regulations for accident prevention and safety in theworkplace must be complied with. Any internal regulations of the operator must also becomplied with, even if these are not mentioned in this manual. Degree of protection according to EN 60529:Please ensure that the ambient conditions at the site of use does not exceed the requirements for the stated protection rating (§ 9 "Technical data"). Prevent freezing of the medium in the device with appropriate measures.Only use the FMG90B if it is in perfect condition. Damaged or faulty devices must be checked without delay and, if necessary, replaced.When fitting, connecting and removing use only suitable appropriate tools.Do not remove or obliterate type plates or other markings on the device, as otherwise thewarranty is rendered null and void. Special safety instructions:Crystallizing liquids:Liquids which crystallize when dried out can cause a malfunction of the FMG90B. Make sure that the FMG90B is not run dry.Prevent the crystallization of the fluid in the device by taking appropriate measures.Further warnings that are specifically relevant to individual operating procedures or activities can be found at the beginning of the relevant sections of this operating manual.Construction and function FMG90B Series- 8 -3 Construction and functionComponents:① Housing:The Housing consists of plastic and has the IP65 degree of protection.② Electrical connection:The electrical connection is made via 4-pin plug M12x1.③ Operation / flow indicator LED.④ Process connection:The process connections are available in different sizes.Construction:The measuring tube with its grounding sleeves and electrodes passes through the housing and forms the external process connection of the FMG90B.A magnetic field for the measurement process is generated inside the housing, which also contains the sensor and signal conditioning circuitry.The two stainless steel electrodes are located in the middle of the measuring tube between the grounding sleeves.The FMG90B does not need any moving parts to make measurements. The inside of the measuring tube is completely open, allowing the fluid to flow unhindered through the measuring tube.Function:The magnetic inductive flow sensor functions according to the induction principle. A DC voltage is generated by the movement of a conductor in a magnetic field:The measuring tube of the FMG90B is located in a magnetic field (B).An electrically conductive medium (V) flows through the measuring tube. The positive and negative charge carriers are oppositely deflected.A voltage (U) is generated at right angles to the magnetic field, which is picked up by the two electrodes.Thereby, the induced voltage is proportional to the average flow velocity of the liquid.The electronics of the FMG90B converts the induced voltage into a flow-proportional frequency signal.FMG90B Series Installation of FMG90BTechnical changes reserved - 9 -4 Installation of FMG90BBefore installing, check that❒ the wetted materials of the device are suitable for the media being used( § 9 “Technical data”).❒ the equipment is switched off and is in a safe and de-energized state. ❒ the equipment is depressurized and has cooled down.SUITABLE TOOLS:Use only suitable tools of the correct size.4.1 Installation instructionsCAUTION! Risk of malfunction due to external magnetic fields! Magnetic fields close to the device can cause malfunctions and should be avoided.Ensure that no external magnetic fields are present at theinstallation site of the FMG90B.•The FMG90B can always be installed anywhere along the pipeline. However, straight sections of piping are preferable.Bubble-formation / run empty possibleDirt deposits possibleRun empty possibleDirt deposits possibleInstallation of FMG90BFMG90B Series• Installation can occur in horizontal and vertical pipes. The flow sensor is only suitable for application in completely filled pipe systems.•As a matter of principle magnetic inductive flow sensors are widely independent from the flow profile. An inlet section is not absolutely necessary.To reach a most highly accuracy of the measurement, you should use straight inlet and outlet sections according to the inner diameter. The inlet section has to be at least10 x inner diameter; the outlet section 5 x inner diameter in order to achieve the specified accuracy.•The inlet and outlet sections and the gaskets must have the same or a slightly larger inside diameter than the measuring tube in order to achieve the specified accuracy.•If two or more FMG90B devices are used side by side, maintain a separation of at least 1.0 in between adjacent devices.If adjacent devices are too close together, operation of both devices may be impaired due to mutual interference.4.2 AssemblyThe FMG90B is installed directly into the pipeline. The compact design and light weight of the unit make wall-mounting unnecessary.IMPORTANT NOTICES:• Only use suitable gaskets for installation.• Observe the flow direction indicated on the type plate. • Observe the mounting dimensions (♑ § 9.3 “Dimensions”).Select an appropriate location for installation(♑ § 4.1 "Installation instructions").To ensure the best possible measuring accuracy, a vertical installation position with increasing flow is preferable (no collecting of dirt deposits).Wrap the FMG90B connections with 1 to 2 wraps of threadtape (e.g. Teflon ® tape). Wrap tape in a clockwise direction, viewed form the end, leaving the first two threads uncovered. Make sure the tape does not intrude into the flow path.Attach the FMG90B with arrow pointed in the direction of flow. The fittings should be screwed into FMG90B hand tight.CAUTION! Material damage! Maximum torque 3.7 ft lb.While tightening, counter the FMG90B only by hand!If you use an open-end or a pipe wrench, the FMG90B can be damaged.To tighten the FMG90B, use an open-end or a pipe wrenchfor the fittings and only the hand for the FMG90B.FMG90B Series Electrical connection 5 Electrical connectionThe electrical connection of the FMG90B is made via the 4-pin plug M12x1 at the top of the housing.The wiring of the FMG90B depends on the ordered version. A distinction is made between frequency output or analog output and frequency output.CAUTION! Electric current!The electrical connection should only be carried out by a fully qualified electrician.De-energize the electrical system before connecting the FMG90B.Connection cable:Suitable connection cables with molded coupling socket M12x1 are available in different lengths as OMEGA accessories. The maximum permissible cable length is 10 m. Connection 4-pin plug M12x1:Screw the coupling socket of the connection cable to the plug of the FMG90B.Tighten the knurled nut of the coupling socket with a maximum torque of 1 Nm.Electrical connection FMG90B Series5.1 WiringsPinout:The pinout differs according to the chosen configuration of the device. Pinout:M12x1Possible pinout: Pin 1: +U BPin 2: n. c. (not connected) / Analog U/I Pin 3: GNDPin 4: FrequencyConnect the connection cable according to your version and the pinout on the type plate.Supply voltage:FMG90B with frequency output:Push-Pull:NPN Open Collector:PNP Open Collector:*1: Push-Pull switching outputs of several FMG90B may not be connected in parallel. *2: Recommendation Pull-Up / Pull-Down resistance R L ~2.5 k Ω (12 V) or ~5 k Ω (24 V). Ensure that the maximum signal current of 25 mA is not exceeded.Use of frequency and analog outputRecommendation for resistance R L ~2.5 k Ω (12 V) or ~5 k Ensure that the maximum signal current of 25 mA is not exceeded.FMG90B Series Commissioning and measuring operation6 Commissioning and measuring operationBefore switching on the FMG90B for the first time, please follow the instructions in the following section.6.1 CommissioningCheck that❒ the FMG90B has been installed correctly and that all screw connections are sealed. ❒ the electrical wiring has been connected properly. ❒ the measuring system is vented by flushing.6.2 Switching on and offThe FMG90B has no switch and cannot be switched on or off on its own. Switching on and off is carried out by the applied supply voltage. Switch on the supply voltage.The green LED lights up. The FMG90B is ready and goes into measuring mode.6.3 Measuring operationIn the measuring mode, the green LED flashes proportional to the measured flow.For the human eye, the flashing is no longer visible from a frequency of ~30...40 Hz.The green LED then seems to light up permanently.FMG90B with frequency output:The FMG90B provides according to the version a flow proportional NPN, PNP or Push-Pull square wave signal.The frequency of the pulse output changes according to the flow ( Fig.).FMG90B with analog output:According to the configuration of the FMG90B, the analog output provides a voltage or current signal.This signal is proportional to the measured flow. You will find the scaling of the analog output on the type plate.Maintenance and cleaning FMG90B Series7 Maintenance and cleaningMaintenance:The FMG90B is maintenance-free and cannot be repaired by the user. In case of a defect, the device must be replaced or sent back the manufacturer for repair.CAUTION! Material damage!When opening the device, critical parts or components can be damage. Never open the device and perform any repair yourself.Cleaning:Clean the FMG90B with a dry or slightly damp lint-free cloth. Do not use sharp objects or aggressive agents for cleaning.FMG90B Series Disassembly and disposal 8 Disassembly and disposalCAUTION! Risk of injury!Never remove the device from a plant in operation.Make sure that the plant is shut down professionally.Before disassembly:Prior to disassembly, ensure that❒the equipment is switched off and is in a safe and de-energized state.❒the equipment is depressurized and has cooled down.Disassembly:Remove the electrical connectors.Removethe FMG90B using suitable tools.Disposal:NO HOUSEHOLD WASTE!The FMG90B consists of various different materials. It must not be disposed of with household waste.Take the FMG90B to your local recycling plant.Technical data FMG90B Series9 Technical dataThe technical data of customized versions may differ from the data in these instructions. Please observe the information specified on the type plate.9.1 Characteristics FMG90B** Voltage output 0.5…10 V only available with 16…24 VDCFMG90B Series Technical data 9.2 Materials table* Available for FMG93B, FMG96B, FMG98BTechnical data FMG90B Series9.3Pressure dropFMG93BFMG96BFMG98B0.00.51.01.52.02.53.00.10.20.30.40.50.6P r e s s u r e d r o p ∆p [p s i ]Flow rate Q [GPM]0.00.51.01.52.02.50.250.50.7511.251.5P r e s s u r e d r o p∆p [p s i ]Flow rate Q [GPM]0.000.501.001.50123456P r e s s u r e d r o p ∆p [p s i ]Flow rate Q [GPM]FMG90B Series Technical dataFMG915B FMG920B FMG925B0.0000.1250.2500.3750.500024******** Pressuredrop∆p[psi]Flow rate Q[GPM]0.00.51.01.52.0010********Pressuredrop∆p[psi]Flow rate Q[GPM]0.00.10.20.30.40.5010203040506070 Pressuredrop∆p[psi]Flow rate Q[GPM]Technical data FMG90B Series9.4 DimensionsFMG90B:FMG925B:FMG90B Series For your notes For your notesFor your notes FMG90B Series For your notesM5759/0220FMG920B-SS-VO-NPT。
电磁流量计说明书目录一、产品概述二、工作原理三、产品特点四、外形尺寸五、流量选型及安装六、流量计接线图七、按键说明与菜单调试八、故障分析与排除九、电磁流量计电极内衬选择表一、产品概述智能电磁流量计是我公司采用先进技术研制、开发与生产的液体流量测量仪表,具有高精度、高可靠性与使用寿命k等优点。
为确保产品质量,我公司在设计产品结构、选材、制定工艺、生产装配与出厂测试等过程中,对每个环节细致研究与控制,并配套完整的流量标定检测系统。
产品执行标准:JB/T 9428-1999。
二、工作原理智能电磁流量计测量原理是基于法拉第电磁感应定律。
即当导电液体流过电磁流量计时,导体液体中会产牛与平均流速V(体积流量)成正比的电压,其感应电压信号通过两个与液体接触的电极检测,通过电缆传至放大器,然后转换成统一的输出信号。
基于电磁流量计的测量原理,要求流动的液体具有最低限度的电导率。
图1:结构原理图E=KBDK:比例常数B:磁感应强度D:测量管内径V:测量管截面的平均流速图2:信号流程图三、产品特点★低频三值矩形波恒流励磁,不受工频及现场各种杂散干扰的影响,性能稳定可靠。
★采用非均匀磁场的新技术及特殊磁路结构,磁场稳定可靠,且缩小了体积,减轻了重量,使流量计具有小型轻量化的特点。
★具有空管自动检测与电路处理功能。
★可根据用户实际需求现场在线修改量程。
★测量管内无阻流件,因此无附加压力损失。
★测量结果与液体的压力、温度、密度、粘度、电导率(小小于最低电导率)等物理参数无关。
★直管段相对要求较短★使用方便,安装后只需接上电源,不需其它任何操作,即可输出标准信号,便于非专业人员使用。
性能数据衬里及公称通径DN(mm):橡胶衬电:40,50,65,80,100,125,150,200,250,300,350,400,450,500,600,700,800. 900. 1000. 1200. 1400, 1600. 1800. 2000. 2200四氟衬里:10,15,20,25,32,40,50,65,80,100,125,150,200,250,300,350,400, 450. 500. 600. 700. 800. 900. 1000. 1200, 1400. 1600, 1800. 2000. 2200 注:特殊规格可订制测量误差:±0.5%、±1.0%、±1.5.被测介质温度:氯橡胶衬咀:-20℃~+65℃,聚四氟乙烯:-30℃~+180℃,聚氯脂橡胶:-20℃~+80℃,聚丙烯:-20℃~ +100℃环境温度:-25 ~+45℃相对湿度:5% - 95%额定压力:DN10-DN80: 4.0MPa DN100-DN150: 1 .6MPa DN200-DN1000: 1 .0Mpa DN1200-DN2000: 0.6MPa DN2200:0.25MPa流速范围:0. 3-12m/s电导率:被测流体电导率不小于5us/cm输出信号及负载电阻:0-10mADC,0-1000nΩ输出频率上限:l~ 5000Hz没定4-20rnADC,0-500 Ω具有防雷击保护串行通讯:可选RS232C或RS485脉冲输出上限5000CP/S;脉冲当量为0.0001~1.0 m3/CP;脉冲宽度:自动设置20ms或方波电级材料:含不锈钢(M02Ti)、钛(Ti)、钽(Ta)、哈氏合金(HB)、铀(Pt)防护等级:标准IP65、IP67、可选IP68直管段长度:上游≥10DN,下游≥5DN连接方式:管道法兰连接,符合标准:GB9119-88功耗:<25W供电电源:220V AC±10%,50HZ±5%、24VDC直流供电产品分类:管道式电磁流量计分一体型和分体型一体型分体型四、外形尺寸4.1产品的外形图34.2产品安装尺寸4.2.1平法兰型电磁流量计(含传感器的)外形及连接尺寸:(见图4、表1)图4表1平法兰型传感器连接尺寸和连接法兰安装尺寸(mm)4.2.2凹凸环槽法兰型电磁流量计(含传感器的)外形及连接尺寸(表2)表2凹凸环槽法兰型与管道连接尺寸:(mm)4.2.3螺纹连接型电磁流量计(含传感器的)外形及连接尺寸(表3)表3螺纹连接型与管道连接尺寸(mm)五、流量选型及安装如何选型正确选用电磁流量计是保证用好电磁流量计的前提条件,选用什么种类的电磁流量计应根据被测液体介质的物理性质和化学性质而决定。
北京铁强科技发展有限公司电磁流量计使用说明型号:TQ-EMF→注重仪器仪表事业的繁荣与发展←工作原理工作原理基于法拉第电磁感应定律。
即当导电液体渡过电磁流量计时,导体中会产生感应电动势,其感应电动势与导电液体流速、磁感应强度、导体宽度(流量计内径)成正比。
该感应电动势由流量计管壁上的一对电极检测到,通过运算就可以得到流量。
感应电动势议程为:E=D·V·B其中:E:感应电动势 D:测量管内径 V:流速 B:磁感应强度为了获得满意的测量精度,必须满足以下条件:(一)被测液体必须具有导电性;(二)液体必须充满管道;(三)液体成分必须均匀;(四)如果液体导磁,流量计磁场将改变,必须对流量计进行修正。
1北京铁强科技发展有限公司2口径10-3200口径10-3200励磁方式 双向恒流方波励磁 励磁方式 双向恒流方波励磁 安装形式 一体型 安装形式 分体型 衬里 氯丁橡胶,PTFE衬里 氯丁橡胶,PTFE电极材料316L ,HC ,HB ,钛,钽,铂铱电极材料SVS316L ,HC ,HB ,钛,钽,铂铱接地 内置接地电极 接地 内置接地电极 介质 导电性液体 介质 导电性液体 精确度等级 0.2, 0.5, 1.0 精确度等级 0.2, 0.5, 1.0 介质电导率 >5μS/cm 介质电导率 >5μS/cm 防爆等级ExdIICT6防爆等级 ExdIICT6 管道连接法兰 GB9119-2000或GB9115-2000管道连接法兰GB9119-2000 或GB9115-2000 管道连接 法兰连接管道连接 法兰连接介质温度氯丁橡胶:-10℃~+60℃; PTPE:-10℃~+120℃介质温度氯丁橡胶:-10℃~+60℃; PTPE:-10℃~+120℃额定压力 4 MPa,1.6 MPa, 1.0 MPa 额定压力 4 MPa,1.6 MPa, 1.0 MPa 防护类别 IP65,IP68防护类别 IP65,IP68输出信号4-20mA 电流,脉冲,上下限报警输出信号4-20mA 电流,脉冲,上下限报警电缆接口 G1/2内螺纹 电缆接口 G1/2内螺纹 通讯 RS485通讯协议通讯 RS485通讯协议显示器显示瞬时流量,百分比,流速,正反向累积流量和总累积量显示器显示瞬时流量,百分比,流速,正反向累积流量和总累积量电源 220V AC ,24V DC 电源 220V AC ,24V DC 使用类型 一般型,防水型 使用类型 一般型,防水型 *高压定做*高压定做特点:● 提高了流量测量的稳定性 ● 快速响应和高稳定性,甚至对于高浓度浆和低电导率液体也如此→注重仪器仪表事业的繁荣与发展←●高可靠性电极结构●通径从10mm到3200mm●交、直流电源均可使用●多功能智能转换器●断电时,EEPROM可保护设定参数和累积值●高清晰度LCD背光显示技术指标电磁流量转换器部件技术指标输入信号:来自检测器的与流量成正比的信号输出信号:4-20mA DC(负载电阴0-750)通过参数设定选择肪冲/报警输出脉冲输出/报警输出:(额定值:30VDC,200mA)通信信号(选择功能)电脑通信信号(叠加在4-20mA DC信号上)负载电阴:205-600(包括电缆电阻)负载电容:最大0.22μF负载电感:最大3.3mH电缆线间距:≥15cm(以避免平行布线)接收仪表的输入的阴抗:≥10K(在2.4Hz时)最大电缆长度:2Km(使用“CEV”电缆时)量程范围设定功能:●通过设定体积单位,流量值和流量计通径来设定体积流量●体积单位:m³●速度单位:m/s●流量计通径:mm●瞬时流量显示功能:显示流量单位显示,也显示量程百分比●累积流量显示功能:可以显示正、反向累积值和总累积值●脉冲输出功能:通过设定一个脉冲系数就可以输出代表任何流量单位所表示的脉冲量●脉冲宽度:占空比50%或固定脉冲宽度供用户选择●输出速率:10-400(脉冲数/秒)(只有在选择脉冲输出方式时使用)3北京铁强科技发展有限公司●失电数据保护:由EEPROM贮存数据,无需备用电池●正、反流量测量功能:在正、反流向测量模式中,可以测量反向流量●上限报警:流量大于上限设定值●下限报警:流量小于下限设定值●阴尼功能:可设定范围从0.2秒-100秒(63%响应时间)正常工作条件:环境温度:-20~60℃电源电压的额定值:220VAC型:100V~240V ACDC型:24V DC安装和结构:安装:分离型:转换器,50mm管道或平面安装组合型:与传感器装成一体导线连接口:ISO M20×1.5内螺纹接线端子:M3螺钉壳体材料:铝合金结构:一般型:防护等级IP65防水型:(IP68)如何正确选型:流量计的选型是仪表应用中非常重要的工作,据有关资料表明,仪表在实际应用中有2/3的故障是仪表的错误选型和错误的安装而造成的,请特别注意。
FLS F6.60电磁流量计安全说明通用说明• 必须按以下说明手册安装并使用产品。
• 此产品设计用于连接其他仪表,如果使用不当,这些仪表可能存在危险。
在使用前,应阅读所有相关仪表手册,并遵守相关规定。
• 产品安装与接线只能由有资质的人员完成。
• 请勿改动产品构造。
安装与调试说明• 在进行输入与输出接线之前,应切断仪表电源。
• 仪表使用不得超过极限值规定。
• 要清洁设备单元,请只使用兼容化学制品。
包装清单请核实产品完整,并且没有任何损坏。
必须包含以下物品:• F6.60 电磁流量计• F6.60 电磁流量计说明手册• 带接口软件的 USB 笔式驱动器• 用于仪表/电脑接口的 USB 电缆说明新型 FLS F6.60 是一种无移动机械部件的流量计,可以用于测量具有导电性的匀质污染液体。
F6.60可以提供三种不同的选项:与FLS流量监视器相连的频率输出,长距离传输和PLC连接的4-20mA输出,以及新的可自由设置的体积脉冲输出。
F6.60插入型电磁流量计装有USB接口和完整专用软件(可从FLS网站免费下载),可以通过电脑按照特殊的安装要求轻松设置所有参数(例如满刻度和截止参数)。
此特定设计可以在DN15(0.5”) - DN600(24”)的宽范围管道尺寸内实现精确的流量测量。
技术数据通用• 管道尺寸范围:DN15 至 DN600(0.5”至 24”)• 最大流量范围:0.05 - 8m/s(0.15 - 26.24 ft./s)• 满量程:8 m/s (26.24 ft/s)• 线性:读数的± 1% + 1.0 cm/s• 可重复性:读数的± 0.5%• 外壳:IP65• 材料:- 箱体:PC/ABS- 垫片:EPDM• 焊接材料:- 传感器本体:316L SS/PVDF;316L SS/PEEK;CuNi合金/PVDF- O形圈:EPDM或FPM- 电极:316L SS 或 CuNi 合金电气• 电源:- 12 - 24VDC±10% 稳压(逆极性和短路保护)- 最大电流:消耗量:250 mA- 保护性接地:< 10 Ω• 电流输出:- 4-20 mA,隔离- 最大环路阻抗:800Ω(24VDC)- 250Ω(12VDC)- 正流量指示或负流量指示• 固态继电器输出:- 用户可选择:最小值警报、最大值警报、体积测定、脉冲输出、窗口警报、关闭- 光隔离,50mA最大漏电流,24VDC最大上拉电压- 最大脉冲/分钟:300- 迟滞:用户可选择• 开路集电极输出(频率):- 类型:开路集电极NPN- 频率:0 – 800 Hz- 最大上拉电压:24 VDC- 最大电流:50 mA,限流- 与FLS M9.02、M9.03、M9.50兼容• 开路集电极输出(方向):- 类型:开路集电极NPN- 最大上拉电压:24 VDC- 最大电流:50mA,限流- 电流方向:0 VDC 箭头方向+ VDC 箭头反向环境• 存储温度:-30°C - +80°C(-22°F - 176°F)• 环境温度:-20°C - +70°C(-4°F - 158°F)•相对湿度:0 - 95%(无结露)• 液体条件:- 均质液体、糊剂或料浆,还有固体成份- 最小电导率:20 μS- 温度:PVDF底部版本:-10°C - +60°C(14°F - 140°F)PEEK底部版本:-10°C - +150°C(14°F - 302°F)• 最大工作压力:- 16 bar @ 25°C (232 psi @ 77°F)- 8.6 bar @ 60°C (124 psi @ 140°F)标准和认证•按照ISO 9001要求制造•按照ISO 14001要求制造•CE•RoHS合规性•GOST R尺寸A 传感器本体B F6.60 电磁流量计1 O形圈(EPDM 或 FPM)2 传感器本体(316L SS 或 CuNi)3 隔离板(PVDF 或 PEEK)4 电极(316L SS 或 CuNi)5 电缆填料盖6 管件内安装使用的 ABS 端帽7 电子盒安装管道位置• 图1中显示的六个最普通的安装配置有助于在管道中为转轮式流量传感器和电磁流量传感器选择最佳位置。
电磁流量计说明书目录一、产品概述二、工作原理三、产品特点四、外形尺寸五、流量选型及安装六、流量计接线图七、按键说明与菜单调试八、故障分析与排除九、电磁流量计电极内衬选择表一、产品概述智能电磁流量计是我公司采用先进技术研制、开发与生产的液体流量测量仪表,具有高精度、高可靠性与使用寿命k等优点。
为确保产品质量,我公司在设计产品结构、选材、制定工艺、生产装配与出厂测试等过程中,对每个环节细致研究与控制,并配套完整的流量标定检测系统。
产品执行标准:JB/T 9428-1999。
二、工作原理智能电磁流量计测量原理是基于法拉第电磁感应定律。
即当导电液体流过电磁流量计时,导体液体中会产牛与平均流速V(体积流量)成正比的电压,其感应电压信号通过两个与液体接触的电极检测,通过电缆传至放大器,然后转换成统一的输出信号。
基于电磁流量计的测量原理,要求流动的液体具有最低限度的电导率。
图1:结构原理图E=KBDK:比例常数B:磁感应强度D:测量管内径V:测量管截面的平均流速图2:信号流程图三、产品特点★低频三值矩形波恒流励磁,不受工频及现场各种杂散干扰的影响,性能稳定可靠。
★采用非均匀磁场的新技术及特殊磁路结构,磁场稳定可靠,且缩小了体积,减轻了重量,使流量计具有小型轻量化的特点。
★具有空管自动检测与电路处理功能。
★可根据用户实际需求现场在线修改量程。
★测量管内无阻流件,因此无附加压力损失。
★测量结果与液体的压力、温度、密度、粘度、电导率(小小于最低电导率)等物理参数无关。
★直管段相对要求较短★使用方便,安装后只需接上电源,不需其它任何操作,即可输出标准信号,便于非专业人员使用。
性能数据衬里及公称通径DN(mm):橡胶衬电:40,50,65,80,100,125,150,200,250,300,350,400,450,500,600,700,800. 900. 1000. 1200. 1400, 1600. 1800. 2000. 2200四氟衬里:10,15,20,25,32,40,50,65,80,100,125,150,200,250,300,350,400, 450. 500. 600. 700. 800. 900. 1000. 1200, 1400. 1600, 1800. 2000. 2200 注:特殊规格可订制测量误差:±0.5%、±1.0%、±1.5.被测介质温度:氯橡胶衬咀:-20℃~+65℃,聚四氟乙烯:-30℃~+180℃,聚氯脂橡胶:-20℃~+80℃,聚丙烯:-20℃~ +100℃环境温度:-25 ~+45℃相对湿度:5% - 95%额定压力:DN10-DN80: 4.0MPa DN100-DN150: 1 .6MPa DN200-DN1000: 1 .0Mpa DN1200-DN2000: 0.6MPa DN2200:0.25MPa流速范围:0. 3-12m/s电导率:被测流体电导率不小于5us/cm输出信号及负载电阻:0-10mADC,0-1000nΩ输出频率上限:l~ 5000Hz没定4-20rnADC,0-500 Ω具有防雷击保护串行通讯:可选RS232C或RS485脉冲输出上限5000CP/S;脉冲当量为0.0001~1.0 m3/CP;脉冲宽度:自动设置20ms或方波电级材料:含不锈钢(M02Ti)、钛(Ti)、钽(Ta)、哈氏合金(HB)、铀(Pt)防护等级:标准IP65、IP67、可选IP68直管段长度:上游≥10DN,下游≥5DN连接方式:管道法兰连接,符合标准:GB9119-88功耗:<25W供电电源:220V AC±10%,50HZ±5%、24VDC直流供电产品分类:管道式电磁流量计分一体型和分体型一体型分体型四、外形尺寸4.1产品的外形图34.2产品安装尺寸4.2.1平法兰型电磁流量计(含传感器的)外形及连接尺寸:(见图4、表1)图4表1平法兰型传感器连接尺寸和连接法兰安装尺寸(mm)4.2.2凹凸环槽法兰型电磁流量计(含传感器的)外形及连接尺寸(表2)表2凹凸环槽法兰型与管道连接尺寸:(mm)4.2.3螺纹连接型电磁流量计(含传感器的)外形及连接尺寸(表3)表3螺纹连接型与管道连接尺寸(mm)五、流量选型及安装如何选型正确选用电磁流量计是保证用好电磁流量计的前提条件,选用什么种类的电磁流量计应根据被测液体介质的物理性质和化学性质而决定。
电磁流量计操作使用说明书目录一、操作指南1.基本设置 (5)1.1 流量单位 (5)1.2 流量显示分辨率 (5)1.3 总量单位 (5)1.4 总量显示分辨率 (5)1.5 阻尼时间(s) (5)2.信号处理设置 (6)2.1 刻度流量 (6)2.2 小信号切除% (6)3.脉冲输出设置 (7)3.1 频率上限 (7)3.2 脉冲当量 (7)3.3 脉冲宽度 (7)3.4 脉冲电平 (8)3.5 频率/脉冲输出选择 (8)4.RS485输出设置 (8)4.1 通讯协议选择 (8)4.2 波特率 (8)4.3 数据位 (9)4.4 校验方式 (9)4.5 设备地址 (9)5.累计管理 (9)5.1 清累计 (9)5.2 预置累计 (9)6.仪表校准 (10)6.1 4mA校准 (10)6.2 20mA校准 (10)6.3 零点校准 (10)7.工厂设置 (11)7.1 传感器口径 (11)7.2 转换器系数 (11)7.3 传感器系数 (12)7.4 励磁频率 (12)7.5 低流量报警开关 (12)7.6 高流量报警开关 (12)7.7 空满管检测开关 (12)7.8 高流量报警点% (13)7.9 低流量报警点% (13)7.10 RS485功能开关 (13)7.11 非稳态时间 (13)7.12 响应极限........................................................................................ 1错误!未定义书签。
7.13 响应时间........................................................................................ 1错误!未定义书签。
7.14 保存设置........................................................................................ 1错误!未定义书签。
电磁流量计操作说明书第一章引言电磁流量计是一种用于测量导电液体流量的仪器,其原理基于法拉第电磁感应定律。
本操作说明书旨在帮助用户正确操作电磁流量计,确保其正常运行并获得准确的流量测量结果。
在使用本仪器之前,请仔细阅读本说明书并按照其中的操作步骤进行操作。
第二章仪器概述2.1 外观与结构电磁流量计主体由流量传感器和转换器组成。
流量传感器通常由两个平行的电极和一对辅助电极构成,其中两个平行电极用于产生磁场,辅助电极用于测量电导率。
转换器则负责接收传感器信号并进行处理,最终将流量值输出到显示屏或其他记录设备。
2.2 规格与参数根据不同型号的电磁流量计,规格和参数会有所差异。
在使用前,请查看所购买的电磁流量计的技术手册,了解其具体规格和参数。
第三章安装与调试3.1 安装3.1.1 安装环境电磁流量计的安装环境应满足以下条件:- 温度范围:XX℃至XX℃- 相对湿度:不大于XX%- 安装位置:远离磁场干扰和强电磁波辐射源- 安装方向:尽量保持垂直安装3.1.2 安装步骤根据安装环境特点和流量计型号的不同,具体的安装步骤可能会有所差异。
请按照以下一般步骤进行操作:1) 确保安装环境符合要求。
2) 将流量计与管道连接,确保连接牢固并无泄漏。
3) 连接电磁流量计的电缆至转换器。
4) 检查安装是否正确,确保传感器与管道之间没有间隙或阻塞物。
5) 安装完成后,检查各连接部位是否紧固。
3.2 调试完成安装后,进行如下调试步骤:1) 检查电源线是否连接正确并插入可靠。
2) 按照转换器说明书设置各参数。
3) 打开阀门,使介质流经流量计。
4) 根据需要进行校准,并记录相关参数。
5) 检查转换器显示的流量值是否与实际值一致。
第四章使用与维护4.1 使用注意事项在正常使用电磁流量计时,需注意以下事项:1) 请勿撞击仪器或使用硬物敲打仪器外壳。
2) 请勿让电磁流量计接触强酸、强碱等腐蚀性物质。
3) 请勿将电磁流量计放置在温度过高或过低的环境中。
LDG型电磁流量计用途、特点、工作原理 1 主要技术参数 2 选型参数及型号标记 2 结构与安装 5 电磁流量计转换器使用说明8 流量计在管线上的安装 20LDG 型电磁流量计用 途电磁流量计是一种测量导电介质体积流量的感应式仪表,适用于测量电导率大于5μs/cm 导电液体的体积流量,可广泛应用于石油、化工、冶金、自来水等领域的源水、净水、污水及其它导电液体的流量计量。
本厂生产的“津成牌”一体型和分体型电磁流量计是采用隔爆设计和普通型设计。
防爆标志为ExdmIIBT4特 点测量管内无活动及阻流部件,无压力损失。
测量不受液体的密度、粘度、温度、压力和电导率变化的影响。
选用不同衬里材料及电极材料,具有良好的耐腐蚀性和耐磨性。
选用不同衬里材料及电极材料,具有良好的耐腐蚀性和耐磨性。
转换器设计成小型低功耗模块,耗电仅0.3瓦。
转换模块安装在传感器的接线盒内即将传感器与转换器组装成一体省去传感器与转换器之间的连接电缆,安装简单方便。
它与显示仪表的连接只用双芯屏蔽电缆,用户十分方便。
用户不需要做任何调试。
不可自行拆装以免破坏密封性能。
出厂时已做好防水性能试验。
工作原理电磁流量计工作原理(见图1)是基于法拉第电磁感应定律。
即:导电液体在磁场中作切割磁力线运动时,在垂直于流速方向和磁场方向上就会产生感应电动势,其感应电动势为:E=BdV式中: B —磁感应强度 (T )D —电极间距 (m ) V —流体平均流速 (m/s) F —导管内截面积 (m 2)对于同一台流量计d 、F 、B 均是固定值,所以流量Q(或流速V),与感应电动势E 的大小成正比。
由此可见,感应电动势E 与流量Q(或流速V)成正比,经过处理运算后,进行瞬时流量和累积流量的计量。
图1 工作原理图主要技术参数1. 测量范围及精度:见表1流量:Q=3600VF (m 3/h)则:Q=3600)/(3h m E BdF表1测 量 范 围 (m/s )精 确 度 > 0.5~10 ±0.5%R ;±1.0%R 0.1~0.5±0.005m/s ;±0.0075m/s2.连接方式:法兰连接、法兰夹装3.外壳防护等级:IP65 Ip67 Ip68 现场显示型(也称一体型)防护等级为IP65。
电磁流量计(使用说明书)1 特点及用途1.1 特点电磁流量计是根据法拉第电磁感应定律制成的可测量导电液体、浆液体积流量的仪表,YMHLD电磁流量计具有以下特点:l 测量不受流体密度、粘度、温度、压力和电导率变化的影响;l 测量管内无阻碍流动部分、无压损,直管段要求低;l 全数字量处理,抗干扰能力强,测量可靠,精度高,流量范围可达1500:1;l 转换器采用16位嵌入式微处理器及表面安装技术参数设定方便.全汉字菜单操作,使用方便简单,具有自检与诊断功能.l 具有双向流量测量功能,能显示正、反向流量,并具备双向电流、频率输出,便于不同流向信号的分别纪录、保存.l 内部具有三个计算器,可分别显示正向累计、反向累计量及差值计算量.l 具有RS485或RS232数字通讯信号输出.1.2 主要用途可用于测量封闭管道中导电液体和浆液的体积流量.广泛适用于石油、化工、电力、矿冶、给排水、造纸、医药、食品等部门的生产工艺过程流量测量和控制.1.3 使用环境条件环境温度:分离型传感器 -25℃~+60℃ 一体型及转换器(工作温度) -10℃~+60℃ 相对温度:5℅~100℅ 1.4 工作条件 液体最高温度:一体型 70℃ 分离型 聚四氟乙烯衬里 100℃,150℃ 聚氯丁橡胶衬里 80℃,120℃ 聚氨酯衬里 80℃ 液体电导率:不低于5μS/cm; 公称压力:法兰型 4.0MPa、1.6MPa、1.0MPa 2 产品型式 2.1 级成及分类 转换器与传感器分离安装的组成分体式流量计;转换器与传感器一体安装的组成一体式流量计。
2.2 转换器与传感器外形及安装尺寸转换器外形尺寸(图1)图1传感器外型尺寸(表1)外 形 尺 寸 / mm 公称通径/mm 高A 宽B 长C 15 180 140 200 20 180 140 200 25 180 140 200 40 210 170 200 50 235 170 200 80 240 200 200 100 268 235 250 150 325 300 300 200 380 340 350 250 438 405 400 300 510 460 500 400 620 580 600 500 736 715 600 600 850 840 600 700 920 895 700 800 1318 1015 800 900 1140 1115 900 10001245 1230 1000图2表1连接法兰及安装尺寸法兰连接尺寸符合下列标准DN15—DN150 4.0MPa GB9119.10-88 DN200—DN600 1.6MPa GB9119.4-88 DN700—DN1000 1.0MPa GB9115.3-88连接法兰 图3表2压力 法兰标准公称直径/mm D D1 d0 Th n B 15 95 65 14 M12 4 16 20 105 75 14 M12 4 18 25110 85 14 M12 4 18 40150 110 18 M16 4 20 50 165 125 18 M16 4 20 80 200 160 18 M16 8 22 100 235 190 22 M20 8 26 4.0MPaGB9119.10-88150 300 250 26 M24 8 28 200 340 295 22 M20 12 26 250405 355 26 M24 12 32 300 460 410 26 M24 12 32 400580 525 30 M27 16 38 500 715 650 33 M30 20 44 1.6MPa GB9119.4-88 600 840 770 36 M33 20 52 700895 840 30 M27 24 46 800 1015 950 33 M30 24 52 9001115 1050 33 M30 28 56 1.0MPa GB9115.3-88 1000 1230116036M3328623 技术性能3.1 执行标准 JB/T9248-1999电磁流计 3.2 流量计和传感器公称通径:15 20 25 40 50 80 100 150 200 250300 400 500 600 700 800 900 1000最高流速:15m/s流量测量范围:流量上限值的流速可在0.3m/s ~15m/s 范围内选定,下限值的流速可为上限值的1% 精确度:示值的±0.5% ±3mm/s 衬里材料:聚四氟乙烯、聚氯丁橡胶、聚氨酯 电极材料:不锈钢0Cr18Ni12Mo2ti哈氏合金B、哈氏合金C、钛、钽、铂/铱合金、不锈钢涂覆碳化钨 连接法兰材料:碳钢 不锈钢 (订货时请注明) 衬里保护法兰材料:不锈钢 1CR18Ni9Ti; 20#合金钢(当流体为强腐蚀性介质时选用须在合同注明)接地法兰材料:不锈钢琴1CR18Ni9Ti进口保护法兰材料:不锈钢1Cr18Ni9Ti外壳防护:分离型橡胶或聚氨酯衬里传感器 IP68 水下10m其它传感器和所有转换器 IP65 间距:转换器与传感器间距一般不超过100米4 安装传感器可安装在任何位置,垂直水平也可倾斜,但安装应保证测量管内任何时候都能充满介质,不得有不满管现象或者有大量气泡能过传感器(图4)传感器水平安装时电极中心轴线尽量水平(图5)图4 图5对于液固两相介质,最好是垂直安装(图6)传感器应远离大功率变频器或强磁场源。
AXWD25电磁流量计说明书AXWD25电磁流量计使用说明书一、概述1适用范围本规程适用于石化企业中在线使用的IFM型电磁流量计,其他同类型仪表参照使用。
2工作原理及特点电磁流量计是基于电磁感应定律而工作的流量测量仪表。
当导电的被测介质垂直于磁力线方向流动时,在与介质流动和磁力线都垂直的方向上产生一个感应电动势EX,它与被测介质在磁场中运动的速度成正比,其关系式如下:EX=BDv式中B——磁感应强度,T;D——导管直径,即导体垂直切割磁力线的长度,m;D-v——被测介质在磁场中运动的速度,m/s。
流体流速v与管道截面积A相乘,即可得体积流量Q。
因此,它是一种速度式流量计。
它由检测和转换两个单元组成。
被测介质流经检测单元变换成感应电势,然后再由转换单元将感应电势放大,转换成4~20mADC的直流标准信号输出,或转换成脉冲信号输出。
电磁流量计适用于导电液体的测量,不能测量气体和导电率极低的油类、有机溶剂。
采用涂层或耐腐蚀衬里,可用于测量各种腐蚀性液体的流量,也可用来测量含有固体颗粒或纤维液体的流量。
电磁流量计测量时不受流体的温度、压力、密度、粘度及流动状态等参数的影响;检测部分无可动部件和突出于管道的部件;几乎没有压力损失;没有测量滞后现象,反应灵敏;输出信号与流量大小呈线性;测量范围宽,可测正反方向流体的流量。
二、技术标准1测量精度:±0.5%;±2.5%(与流速有关)。
2流速范围:0~10m/s。
3通径范围:2.5~3000mm。
4流体电导率:>5~20µS/cm(标准型)>0.1µS/cm(低导电率型)5输出信号:4~20mADC或脉冲信号。
6环境温度:-20~60℃。
7电源电压:24VDC、100~240VAC/48~63HZ。
上述技术指标及其他技术指标如:使用温度和压力、电缆线长度、电极和衬里材料、外壳密封类型、防暴等级以及电源电压等根据不同型号制造厂均有具体规定。
KA026D/06/zh/11.0971106919简明操作指南Proline Promag 50电磁流量测量系统68本《简明操作指南》不能替代供货范围中的《操作手册》。
详细信息请参考《操作手册》以及随附CD 上的其它文档。
完整的设备文档包括:•《简明操作指南》•与仪表型号相符的相关文档:–《操作手册》和《仪表功能描述》–防爆证书及安全证书–安装指南 - 与仪表型号相关(例如防爆证书、压力设备规程等)–其它相关信息目录Proline Promag 50目录1 安全指南. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 用途 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 安装、调试和操作 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.3 操作安全 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.4 安全图标 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.1 运往测量点 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.2 安装条件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.3 Promag W和Promag L传感器的安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.4 Promag P传感器的安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.5 Promag W、Promag P和Promag L的紧固扭矩 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.6 Promag H传感器的安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.7 变送器外壳的安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.8 安装后检查 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263 接线 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273.1 不同外壳类型的仪表连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283.2 分体式仪表的电缆连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293.3 电势平衡 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323.4 防护等级 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333.5 连接后检查 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334 硬件设置. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344.1 设备地址 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344.2 终端电阻 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365 调试 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375.1 开启测量设备 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375.2 运行 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385.3 浏览功能表 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395.4 调用快速设定 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405.5 软件设置 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415.6 故障检测 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 2Endress+HauserProline Promag 50安全指南1安全指南1.1用途•本测量设备仅用于测量密闭管道中导电介质的流量。
精心整理LDC 型 电磁流量计使用说明书1产品用途与适用范围1.1■ ■ 采用■ ■ 超低■ ■ ■ ■ ■ 具有■ ■ ■ 采用■ 1.2 水利1.3 1.4相对湿度:45%~85% 电源电压:220±2% 电源频率:50Hz ±5% 谐波含量小于5%。
预热时间:30min2 产品型式电磁流量计有分体型和一体型两种结构形式。
3 工作原理电磁流量计的工作原理基于法拉第电磁感应定律。
当一个导体在磁场内运动,在与磁场方向、运动方向相互垂直方向的导体两端,会有感应电动势产生。
电动势的大小与导体运动速度和磁感应强度大小成正比。
在图1-1中,当导电流体以平均流速V (s m /)通过装有一对测量电极的一根内径为D (m )的绝缘管子流动时,并且该管子处于一个均匀的磁感应强度为B (T )的磁场中。
那么,在一对电极上就会感应出垂直于磁场方和流动方向的电动势(E )。
由电磁感应定律可写做(1)式:V D B E ⋅⋅=(V ) (1)通常,体积流量可以写作V Dq4π=(s m /) (2)由公式(1)和(2)可得到:smq 因此电动势可表示为:/q 可见,流量q 与电动势成正比。
图1-2 转换器电路结构电磁流量转换器一方面向电磁流量传感器励磁线圈提供稳定的励磁电流,以达到B 是个常量;同时把传感器感应的电动势放大、转换成标准的电流信号或频率信号,便于流量的显示、控制与调节。
图1-2所示为转换器电路结构。
4 技术性能指标4.1执行标准JB/T9248-1999电磁流量计。
4.2基本参数与性能指标4.2.1传感器公称通经:3、6、10、15、20、25、32、40、50、65、80、100、125、150、200、250、300、350、400、450、500、600、700、800、900、1000、1200、1400、1600、1800、2000、2200、2400、2600、2800、3000;4.2.2流量测量范围流量测量范围上限值的流速可在0.3m/s~15m/s范围内选定,下限值的流速可为上限值的1%。
电磁流量计使用说明书1. 产品概述电磁流量计是一种测量导电液体流量的仪器,广泛应用于化工、水处理、食品加工等行业。
本说明书将详细介绍产品的安装、操作和维护等方面的内容,以确保用户正确地使用电磁流量计。
2. 安装与连接2.1 安装位置选择安装位置时,请确保离直管段足够远,避免管道弯曲、缩径等影响流量测量的因素。
2.2 连接在连接前,请先确保电磁流量计与电源之间断开电源,并根据接线图连接导线。
3. 操作与显示3.1 开机与关机打开电源开关,电磁流量计开始运行;关闭电源开关,电磁流量计停止运行。
3.2 参数设置按照设备说明书,使用相应按键进行参数设置,包括单位、流速范围等。
3.3 数据显示电磁流量计的显示屏将实时显示流量数据,用户可以通过触摸屏切换显示方式,如流速、流量等。
4. 维护与保养4.1 清洁定期清洁电磁流量计外壳,可使用软布蘸取清水轻轻擦拭,切勿使用腐蚀性溶剂。
4.2 校准根据使用情况,在规定的周期内进行校准操作,确保测量结果的准确性。
4.3 故障排除当电磁流量计出现故障时,请先检查电源是否正常,接线是否松动,并参照说明书进行故障排查。
5. 注意事项5.1 使用环境电磁流量计应在避免强磁场干扰的环境中使用,且温度范围应符合设备规定。
5.2 防雷防护安装时请注意防止雷击,可使用避雷装置进行防雷保护。
5.3 运输与存储妥善包装并避免重压,存放在干燥通风的地方,避免阳光直射和潮湿环境。
6. 技术支持与售后服务如需技术支持或售后服务,请联系我们的客服热线或发送邮件至指定邮箱,我们将竭诚为您提供帮助。
7. 免责声明本使用说明书中的内容仅供参考,如在实际使用中出现问题,请以最新的设备说明书为准。
电磁流量计使用说明书到此结束,感谢您的阅读与使用。
如有任何疑问,请及时联系我们。
科隆电磁流量计300说明书 IFC300一、概述IFC300有四种安装形式:一体型(信号转换器直接安装在传感器上),分体型(信号转换器安装在现场型外壳中),墙挂型(信号转换器安装在墙挂型外壳中),架装型(信号转换器安装在19英寸机架内)。
该信号转换器的电子机芯插件模块是相同的,不同的外壳型号,提供相同的功能和标准化的操作概念。
IFC300还有适用于危险场合使用的版本,满足相关的安全要求和认证。
本说明书旨在为用户提供IFC300的安装、电气连接、启动、操作、维护和故障排除等方面的指导。
请仔细阅读本说明书,并按照本说明书中的要求进行操作。
如有任何疑问或需要技术支持,请连系科隆中国或当地代理商。
二、安全要点请阅读本操作说明书,取得适用的国家标准、安全要求和事故处理规程。
计量仪表的安装和操作只能由具备资质的人员实施。
电源、励磁、信号电缆、输入/输出电缆应使用独立的电缆接入口。
避免太阳光直射,必要时安装遮阳罩。
信号转换器安装在开关箱内时,应有适当的冷却措施,例如用风扇或热交换器。
不要使转换器承受剧烈的振动。
警告符号:电击危险!可能会产生严重的烧伤和伤害!警告!使用在危险场合的仪表有特殊的规定,为了确保在这样的场合安全使用,请务必遵守。
接线、安装、操作和维护只能由经过防爆培训合格的人员实施。
警告!显示或出现时,如果不加关注可能导致人身伤害、危险的场面、带故障工作或仪表的损坏。
注意!显示或出现时,如果不加关注可能导致人身伤害和仪表带故障工作。
信息和提示:提供有用的信息和操作建议。
三、系统描述本章节介绍了IFC300的系统组成、信号转换器型式和铭牌、电源连接、分体型传感器的电气连接等内容。
3.1 系统组成信号转换器:用于将传感器的信号转换为流量信号,并提供显示、操作、输入/输出和自诊断等功能。
传感器:用于测量流体的流速和电导率,并将其转换为电信号。
传感器的型式和口径根据不同的应用而选择。
励磁电缆:用于将信号转换器的励磁电流传输到传感器的线圈,产生磁场。
电磁流量计使用方法说明书一、引言电磁流量计是一种广泛应用于工业生产中的流量测量仪器,本说明书旨在帮助用户准确并有效地使用电磁流量计。
请用户在使用前仔细阅读本文,并按照说明书的步骤进行操作。
二、产品概述电磁流量计是一种利用法拉第电磁感应原理进行流量测量的设备,具有测量范围广、精度高、抗干扰能力强等特点。
本款电磁流量计采用先进的数字信号处理技术,能够实时准确地测量液体介质的流量。
三、安装与连接1. 安装前,用户应确保电磁流量计与管道之间的连接方式正确,并且密封良好。
2. 在安装过程中,应留出足够的工作空间和维修空间。
3. 将电磁流量计的接线端口连接到相应的工控设备或显示器上,并确保连接牢固可靠。
四、操作方法1. 启动电磁流量计前,请确保供电电压符合要求,并检查仪表本身是否处于良好状态。
2. 打开开关,进入电磁流量计的主界面,通过触摸屏或按钮来进行仪表的操作。
3. 在主界面上,您可以选择不同的测量模式、单位、数据显示方式等。
4. 在测量过程中,您可以随时切换不同的显示界面并查看当前流量数据。
五、注意事项1. 请勿将电磁流量计直接暴露于高温、潮湿或者腐蚀性介质中,以免损坏设备。
2. 在操作过程中,应避免外界磁场或电磁干扰对仪表的影响,以免影响测量结果。
3. 定期对电磁流量计进行检测和校准,以保证测量的准确性。
4. 请勿擅自拆卸或修理电磁流量计,如有故障请联系售后服务中心。
六、维护与保养1. 定期清洁仪表表面及传感器部分,保持仪表的整洁外观和正常工作状态。
2. 检查仪表的电源线、接线端口等是否有松动,如有松动请及时固定。
3. 如长时间不使用电磁流量计,请将仪表存放在干燥通风的地方,并避免阳光直射。
七、故障排除如果在使用过程中遇到仪表故障,例如显示异常、测量不准确等情况,请按照以下步骤进行排除:1. 检查电源线是否接触良好,并检查供电电压是否符合要求。
2. 检查传感器接线端口是否松动,重新插拔连接线并固定牢靠。
电磁流量计操作指南说明书
1. 引言
电磁流量计是一种常用的流量测量仪表,广泛应用于工业生产、水处理、石油化工等领域。
本操作指南旨在帮助用户正确操作电磁流量计,提高测量准确性和工作效率。
2. 安装与连接
2.1 安装
根据现场实际情况选择合适的安装位置,确保电磁流量计与被测介质流向一致,并确保安装位置平整、无振动。
安装时应注意保持流量计的垂直放置,并留出足够的空间以便于维修和更换。
2.2 连接
将电磁流量计与管道系统连接,确保连接口紧固可靠,避免泄漏。
请按照电磁流量计与管道连接口的规格选用适当的密封件。
连接完成后,检查连接口是否有松动,若有松动应及时进行重新紧固。
3. 参数设定
在开始测量之前,需进行相关参数的设定,以确保电磁流量计的准确度。
3.1 测量范围
根据被测介质的流量范围,设置电磁流量计的测量范围。
请确保所设置的测量范围能够满足实际测量需求,并预留一定的余量,以防止超量程的发生。
3.2 温度和压力补偿
根据被测介质的实际温度和压力情况,设置电磁流量计的温度和压力补偿参数。
温度和压力补偿能够有效提高测量的准确性,确保测量结果的可靠性。
4. 运行操作
4.1 供电与启动
将电磁流量计与电源进行连接,并确保电源正常供电。
在供电后,按照操作面板上的启动指示进行操作,启动电磁流量计。
4.2 测量显示与记录
在启动后,电磁流量计将实时显示被测介质的流量值。
可以根据需要选择记录仪表或计算机系统进行流量数据的记录与存储,便于后期数据分析和处理。
4.3 异常处理与维护
在日常使用中,若发现电磁流量计的显示异常或其他问题,请及时进行检查和维护。
遇到故障时,应按照设备说明书进行相应的维修操作,或联系售后服务人员进行维修。
5. 注意事项
5.1 防护措施
在安装和操作电磁流量计时,应注意避免其接触任何化学物质,以
防损坏仪表。
同时,应做好防护措施,避免流量计受到外部环境的影响。
5.2 清洁与维护
定期对电磁流量计进行清洁和维护,以保持仪表的良好工作状态。
请使用干净柔软的布进行擦拭,避免使用有腐蚀性或磨损性的清洁剂。
5.3 定期校验
为确保电磁流量计的准确性,建议定期进行校验。
请参考设备说明
书中的校验程序,并按照相关要求进行操作。
6. 常见问题解答
在使用电磁流量计的过程中,常会遇到一些问题。
以下是一些常见
问题的解答,供用户参考:
6.1 为什么电磁流量计的测量结果与实际流量不符?
可能是参数设置不准确,建议重新设置参数。
如果问题依然存在,
可能是仪表故障,建议联系售后服务人员进行维修。
6.2 电磁流量计显示异常怎么办?
可以尝试重新启动电磁流量计,如果问题依然存在,建议检查电源
和连接线路是否正常,或联系售后服务人员进行维修。
7. 结语
本操作指南主要介绍了电磁流量计的操作指南与注意事项。
准确的操作和维护可以确保电磁流量计的工作准确性和使用寿命,希望本指南对用户在使用电磁流量计时有所帮助。
总字数:737字。