bp1133 HLT 23 Workshop 9 - Batch Process- Hexane(双语)2
- 格式:ppt
- 大小:58.00 KB
- 文档页数:2
REPLACEMENT PART REFERENCE GUIDE, YAT-20+AN-70-047aMECHANICAL DIMENSIONSCase Style: MC1630Replacement part uses same case style as original part.CONCLUSION:1) FORM-FIT-FUNCTIONAL ANALYSIS a :The Replacement Part is Form, Fit compatible.Following is a summary of changes/improvements in the Specification:ParameterFrequency (GHz) Original PartReplacement PartAttenuation Min (dB) Attenuation Max (dB) DC-5 19.0 21.52 19.7 20.4 Attenuation Min (dB) Attenuation Max (dB) 5-15 19.2 22.3 19.7 21.0 Attenuation Max (dB) 15-18 22.821.0Input PowerDC-181.5W** at 25°C **Derate linearly to1W at 85°C0.8W** at 25°C **Derate linearly to 0.6W at 85°CEvaluation Board redesigned to use 2.4 mm End-Launch connectors from Southwest to obtain repeatable electrical performanceFollowing is a summary of changes in Evaluation Board/Connectors/PL-Drawing:ParameterOriginal Part Replacement Part Evaluation Board TB-621-20+ TB-YAT-20A+ Connectors SMA End Launch2.4mm End LaunchPL-DrawingPL-349PL-5861 via hole 3 via holesFor typical performance and Graphs: See paragraphs 2 and 32)TYPICAL PERFORMANCE COMPARISON AT ROOM TEMPERATURE: MODEL: YAT-20+, YAT-20A+ (RF Parameters)3)© 2015 Mini-CircuitsIMPORTANT NOTICEThis document is provided as an accommodation to Mini-Circuits customers in connection with Mini-Circuits parts only. In that regard, this document is for informational and guideline purposes only. Mini-Circuits assumes no responsibility for errors or omissions in this document or for any information contained herein.Mini-Circuits may change this document or the Mini-Circuits parts referenced herein (collectively, the “Materials”) from time to time, without notice. Mini-Circuits makes no commitment to update or correct any of the Materials, and Mini-Circuits shall have no responsibility whatsoever on account of any updates or corrections to the Materials or Mini-Circuits’ failure to do so. Mini-Circuits customers are solely responsible for the products, systems, and applications in which Mini-Circuits parts are incorporated or used. In that regard, customers are responsible for consulting with their own engineers and other appropriate professionals who are familiar with the specific products and systems into which Mini-Circuits’ parts are to be incorporated or used so that the proper selection, installation/integration, use and safeguards are made. Accordingly, Mini-Circuits assumes no liability therefore.In addition, your use of this document and the information contained herein is subject to Mini-Circuits’ standard terms of use, which are available at Mini-Circuits’ website at /homepage/terms_of_use.html.Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation d/b/a Mini-Circuits. All other third-party trademarks are the property of their respective owners. A reference to any third-party trademark does not constitute or imply any endorsement, affiliation, sponsorship, or recommendation: (i) by Mini-Circuits of such third- party’s products, services, processes, or other information; or (ii) by any such third-party of Mini-Circuits or its products, services, processes, or other information.。
PMS133/ PMS1348bit OTP带12bit ADC单片机数据手册Version 0.02– Sep. 30, 2017Copyright 2017 by PADAUK Technology Co., Ltd., all rights reserved10F-2, No. 1, Sec. 2, Dong-Da Road, Hsin-Chu 300, Taiwan, R.O.C.TEL: 886-3-532-7598 重要声明应广科技保留权利在任何时候变更或终止产品,建议客户在使用或下单前与应广科技或代理商联系以取得最新、最正确的产品信息。
应广科技不担保本产品适用于保障生命安全或紧急安全的应用,应广科技不为此类应用产品承担任何责任。
关键应用产品包括,但不仅限于,可能涉及的潜在风险的死亡,人身伤害,火灾或严重财产损失。
应广科技不承担任何责任来自于因客户的产品设计所造成的任何损失。
在应广科技所保障的规格范围内,客户应设计和验证他们的产品。
为了尽量减少风险,客户设计产品时,应保留适当的产品工作范围安全保障。
PMS133/PMS134不适用AC阻容降压,强纹波或高EFT要求的产品应用。
提供本文档的中文简体版是为了便于了解,请勿忽视文中英文的部份,因为其中提供有关产品性能以及产品使用的有用信息,应广科技暨代理商对于文中可能存在的差错不承担任何责任,建议参考本文件英文版。
目录1.功能. (9)1.1. 特性 (9)1.2. 系统特性 (9)1.3. CPU 特性 (9)1.4. 封装信息 (10)2.系统概述和方框图 (11)3.引脚功能说明 (12)4.器件电器特性 (21)4.1. 直流交流电气特性 (21)4.2. 绝对最大值范围 (22)4.3. ILRC频率与VDD关系曲线图 (23)4.4. IHRC频率与VDD关系曲线图 (23)4.5. ILRC频率与温度关系曲线图 (24)4.6. IHRC频率与温度关系曲线图(校准到16MHz) (24)4.7. 工作电流vs. VDD与系统时钟= ILRC/n关系曲线图 (25)4.8. 工作电流vs. VDD与系统时钟= IHRC/n关系曲线图 (25)4.9. 工作电流vs. VDD与系统时钟= 4MHz EOSC / n关系曲线图 (26)4.10. 工作电流vs. VDD与系统时钟= 32KHz EOSC / n关系曲线图(保留) (26)4.11. 工作电流vs.VDD与系统时钟= 1MHz EOSC / n关系曲线图 (27)4.12. IO引脚输出的驱动电流(I OH)与灌电流(I OL)曲线图 (27)4.13. IO引脚输入高/低阀值电压(V IH/V IL)曲线图 (29)4.14. IO引脚上拉阻抗曲线图 (30)4.15. 掉电电流(I PD) /省电电流(I PS).vs VDD关系曲线图 (30)4.16. 开机时序图 (31)5.功能概述 (32)5.1. OTP程序存储器 (32)5.2. 启动程序 (32)5.3. 数据存储器-- SRAM (33)5.4. 振荡器和时钟 (33)5.4.1. 内部高频RC振荡器和内部低频RC振荡器 (33)5.4.2. 芯片校准 (33)5.4.3. IHRC频率校准和系统时钟 (34)5.4.4. 外部晶体振荡器 (35)5.4.5. 系统时钟和LVR基准位 (37)5.4.6. 系统时钟切换 (37)5.5. 比较器 (39)5.5.1. 内部参考电压(V internal R) (40)5.5.2. 使用比较器 (42)5.5.3. 使用比较器和band-gap 1.20V (42)5.6. VDD/2 LCD偏置电压产生器 (43)5.7. 16位计数器(Timer16) (44)5.8. 8位PWM计数器(Timer2/Timer3) (46)5.8.1. 使用Timer2产生周期波形 (47)5.8.2. 使用Timer2产生8位PWM波形 (49)5.8.3. 使用Timer2产生6位PWM波形 (50)5.9. 11位PWM计数器 (51)5.9.1. PWM 波形 (51)5.9.2. 硬件时序框图 (52)5.9.3. 11位PWM生成器计算公式 (53)5.10. 看门狗计数器 (53)5.11. 中断 (54)5.12. 省电与掉电 (56)5.12.1. 省电模式(“stopexe”) (56)5.12.2. 掉电模式(“stopsys”) (57)5.12.3. 唤醒 (57)5.13. IO 引脚 (58)5.14. 复位和LVR (59)5.14.1. 复位 (59)5.14.2. LVR 复位 (59)5.15. 模拟-数字转换器(ADC) 模块 (60)5.15.1. AD转换的输入要求 (61)5.15.2. 选择参考高电压 (62)5.15.3. ADC时钟选择 (62)5.15.4. 配置模拟引脚 (62)5.15.5. 使用ADC (62)5.16. 乘法器 (63)6.IO 寄存器 (64)6.1. ACC状态标志寄存器(flag), IO地址= 0x00 (64)6.2. 堆栈指针寄存器(sp), IO地址= 0x02 (64)6.3. 时钟模式寄存器(clkmd), IO地址= 0x03 (64)6.4. 中断允许寄存器(inten), IO地址= 0x04 (65)6.5. 中断请求寄存器(intrq), IO地址= 0x05 (65)6.6. Timer16控制寄存器(t16m), IO 地址= 0x06 (66)6.7. 乘法器运算对象寄存器(mulop), IO地址= 0x08 (66)6.8. 乘法器结果高字节寄存器(mulrh), IO地址= 0x09 (66)6.9. 外部晶体振荡器控制寄存器(eoscr), IO地址= 0x0a (66)6.10. 中断边缘选择寄存器(integs), IO地址= 0x0c (67)6.11. 端口A数字输入使能寄存器(padier), IO地址= 0x0d (67)6.12. 端口B数字输入使能寄存器(pbdier), IO地址= 0x0e (67)6.13. 端口C数字输入使能寄存器(pcdier), IO地址= 0x0f (67)6.14. 端口A数据寄存器(pa), IO地址= 0x10 (67)6.15. 端口A控制寄存器(pac), IO地址= 0x11 (68)6.16. 端口A上拉控制寄存器(paph), IO地址= 0x12 (68)6.17. 端口B数据寄存器(pb), IO地址= 0x13 (68)6.18. 端口B控制寄存器(pbc), IO地址= 0x14 (68)6.19. 端口B上拉控制寄存器(pbph), IO地址= 0x15 (68)6.20. 端口C数据寄存器(pc), IO地址= 0x16 (68)6.21. 端口C控制寄存器(pbc), IO地址= 0x17 (68)6.22. 端口C上拉控制寄存器(pcph), IO地址= 0x18 (68)6.23. ADC控制寄存器(adcc), IO地址= 0x20 (69)6.24. ADC模式寄存器(adcm), IO地址= 0x21 (69)6.25. ADC调节控制寄存器(adcrgc), IO地址= 0x24 (70)6.26. ADC数据高位寄存器(adcrh), IO地址= 0x22 (70)6.27. ADC数据低位寄存器(adcrl), IO地址= 0x23 (70)6.28. 杂项寄存器(misc), IO地址= 0x26 (70)6.29. 比较器控制寄存器(gpcc), IO地址= 0x2b (71)6.30. 比较器选择寄存器(gpcs), IO地址= 0x2c (71)6.31. Timer2控制寄存器(tm2c), IO地址= 0x30 (72)6.32. Timer2计数寄存器(tm2ct), IO地址= 0x31 (72)6.33. Timer2分频寄存器(tm2s), IO地址= 0x32 (72)6.34. Timer2上限寄存器(tm2b), IO地址= 0x33 (73)6.35. Timer3控制寄存器(tm3c), IO地址= 0x34 (73)6.36. Timer3 计数寄存器(tm3ct), IO地址= 0x35 (73)6.37. Timer3 分频寄存器(tm3s), IO地址= 0x36 (73)6.38. Timer3 上限寄存器(tm3b), IO地址= 0x37 (74)6.39. PWMG0控制寄存器(pwmg0c), IO地址= 0x40 (74)6.40. PWMG0分频Register (pwmg0s), IO地址= 0x41 (74)6.41. PWMG0占空比高位寄存器(pwmg0dth), IO地址= 0x42 (74)6.42. PWMG0 Duty Value Low Register (pwmg0dtl), IO address = 0x43 (75)6.43. PWMG0计数上限高位寄存器(pwmg0cubh), IO地址= 0x44 (75)6.44. PWMG0计数上限低位寄存器(pwmg0cubl), IO地址= 0x45 (75)6.45. PWMG1控制寄存器(pwmg1c), IO 地址= 0x46 (75)6.46. PWMG1分频Register(pwmg1s), IO地址= 0x47 (76)6.47. PWMG1占空比高位寄存器(pwmg1dth), IO地址= 0x48 (76)6.48. PWMG1占空比低位寄存器(pwmg1dtl), IO地址= 0x49 (76)6.49. PWMG1计数上限高位寄存器(pwmg1cubh), IO地址= 0x4a (76)6.50. PWMG1计数上限低位寄存器(pwmg1cubl), IO地址= 0x04b (76)6.51. PWMG2控制寄存器(pwmg2c), IO地址= 0x4C (77)6.53. PWMG2占空比高位寄存器(pwmg2dth), IO地址= 0x4E (77)6.54. PWMG2占空比低位寄存器(pwmg2dtl), IO地址= 0x4F (77)6.55. PWMG2计数上限高位寄存器(pwmg2cubh), IO地址= 0x50 (78)6.56. PWMG2计数上限低位寄存器(pwmg2cubl), IO地址= 0x51 (78)7.指令 (79)7.1. 数据传输类指令 (80)7.2. 算数运算类指令 (82)7.3. 移位运算类指令 (84)7.4. 逻辑运算类指令 (85)7.5. 位运算类指令 (87)7.6. 条件运算类指令 (88)7.7. 系统控制类指令 (90)7.8. 指令执行周期综述 (91)7.9. 指令影响标志综述 (92)8.代码选项(Code Options) (93)9.特别注意事项 (95)9.1. 警告 (95)9.2. 使用IC (95)9.2.1. IO引脚的使用和设定 (95)9.2.2. 中断 (95)9.2.3. 系统时间选择 (96)9.2.4. 看门狗 (96)9.2.5. TIMER 溢出 (96)9.2.6. IHRC (96)9.2.7. LVR (97)9.2.8. 指令 (97)9.2.9. BIT定义 (97)9.2.10. 烧录方法 (97)9.2.11. 烧录兼容性 (97)9.3 使用ICE (98)1. 功能1.1. 特性◆通用OTP系列◆请勿使用于AC阻容降压供电,强电源纹波,或高EFT要求之应用◆工作温度范围:-20°C ~ 70°C1.2. 系统特性◆一个硬件16位计数器◆两个8位硬件PWM生成器◆三个11位硬件PWM生成器(PWMG0,PWMG1 & PWMG2)◆一个硬件比较器◆Band-gap 电路提供1.2V参考电压◆最多13通道12位ADC◆ADC 参考高电压:外部输入,内部VDD,Band-gap 1.20V,4V,3V及2V◆一组1T 8x8硬件乘法器◆最多22个IO引脚并带有上拉电阻◆提供三种不同的IO驱动能力以满足不同的应用需求1. PB4,PB7驱动/灌电流= 30mA/35mA (Strong) and 13mA/17mA (Normal)2. 其他IO(除PA5外)驱动/灌电流= 10mA/(13 or 20) mA3. PA5灌电流= 10mA◆每个IO引脚都可设定唤醒功能◆内置1/2 V DD LCD偏置电压产生器,可支持最大4×10点的LCD屏◆时钟源:IHRC,ILRC及EOSC(XTAL)◆对所有带有唤醒功能的IO,都支持两种可选择的唤醒速度:正常唤醒和快速唤醒◆8段LVR复位电压设定:4.0V,3.5V,3.0V,2.75V,2.5V,2.2V,2.0V,1.8V◆两组Code Option可选的外部中断引脚1.3. CPU 特性◆8bit高性能RISC CPU◆提供87个有效指令◆大部分都是1T(单周期)指令◆可程序设定的堆栈指针和堆栈深度◆数据和指令都是直接和间接寻址模式◆所有的数据存储器都可以当作指针◆独立的IO地址和存储器地址注意:“保留”指留作后用。
HP ProDisplay P19A LED Backlit MonitorUser Guide© 2013 Hewlett-Packard Development Company, L.P.The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.This document contains proprietary information that is protected by copyright. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Hewlett-Packard Company.First Edition (April 2013)Document Part Number: 720604–001About This GuideThis guide provides information on monitor features, setting up the monitor, and technicalspecifications.CAUTION:Text set off in this manner indicates that failure to follow directions could result indamage to equipment or loss of information.Text set off in this manner provides important supplemental information.iiiiv About This GuideTable of contents1 Product Features (1)HP LED Monitor (1)2 Setting Up the Monitor (2)Attaching the Stand Base (2)Rear Components (3)Connecting the Cables (4)Front Panel Controls (5)Adjusting the Monitor (6)Turning on the Monitor (6)Using the Accessory Rails (7)Mounting the Monitor Panel (7)Locating the Rating Labels (9)Installing a Cable Lock (9)3 Finding More Information (10)Product Support (10)4 Technical Specifications (11)Preset Display Resolutions (11)Entering User Modes (12)vvi1Product FeaturesHP LED MonitorThe LED (light-emitting diode) monitor has an active matrix, thin-film transistor (TFT) panel. Themonitor features include:●48.2-cm (19-inch) diagonal viewable area display with 1280 x 1024 resolution, plus full-screensupport for lower resolutions; includes custom scaling for maximum image size while preservingoriginal aspect ratio●Non-glare panel with an LED backlight that consumes less energy than traditional CCFLbacklights●Wide viewing angle to allow viewing from a sitting or standing position, or moving side-to-side●Tilt capability●Removable stand for flexible monitor panel mounting solutions●Video signal input to support VGA analog●Accessory rail on monitor to accept optional mounted devices, such as an HP speaker bar●Plug-and-play capability if supported by the operating system●Privacy filter slots to insert filters (purchased separately) to block side screen viewing●Security slot provision on rear of monitor for optional cable lock●On-Screen Display (OSD) adjustments in several languages for easy setup and screenoptimization●HP Display Assistant for adjusting monitor settings and enabling the theft deterrence feature●Software and documentation CD that includes monitor drivers and product documentation●Energy saver feature to meet requirements for reduced power consumption●Safety guidelines, certifications, and regulatory notices for this product is available in the HPLCD Monitors Reference Guide on the CD included with this monitorHP LED Monitor12Setting Up the MonitorTo set up the monitor, ensure that the power is turned off to the monitor, computer system, and otherattached devices, then follow the instructions below.Attaching the Stand Base1.Lift the stand base from the monitor box and set it on a flat surface such as a table top.ing both hands, lift the monitor from its box, position the monitor stand over the stand base,and press down firmly to lock it in place. Be sure the stand base is securely locked in place andadjust the tilt angle to the desired position.normal condition.Figure 2-1 Attaching the Monitor Stand Base2Chapter 2 Setting Up the MonitorRear ComponentsFigure 2-2 Rear ComponentsComponent Function1AC Power Connector Connects the AC power cord to the monitor.2VGA Connects the VGA cable to the monitor.Rear Components3Connecting the Cables1.Place the monitor in a convenient, well-ventilated location near the computer.2.Connect the VGA signal cable.3.Connect one end of the power cord to the AC power connector on the back of the monitor, andthe other end to an electrical wall outlet.Figure 2-3 Connecting the CablesDo not disable the power cord grounding plug. The grounding plug is an important safetyfeature.Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at alltimes.Disconnect power from the equipment by unplugging the power cord from the electrical outlet.For your safety, do not place anything on power cords or cables. Arrange them so that no onemay accidentally step on or trip over them. Do not pull on a cord or cable. When unplugging fromthe electrical outlet, grasp the cord by the plug.4Chapter 2 Setting Up the MonitorFront Panel ControlsFigure 2-4 Monitor Front Panel ControlsTable 2-1 Monitor Front Panel ControlsControl Function1Menu Opens, selects or exits the OSD menu.If the OSD menu is on, press to select the highlightedmenu item.2Minus/Auto If the OSD menu is on, press to navigate backward throughthe OSD menu and decrease adjustment levels.If the OSD menu is inactive, press to activate the autoadjustment feature to optimize the screen image.3Plus If the OSD menu is on, press to navigate forward throughthe OSD menu and increase adjustment levels.4Power LED White = Fully powered.Amber = Sleep modeFlashing Amber = Sleep Timer mode5Power Turns the monitor on or off.at /go/sml.Front Panel Controls5Adjusting the MonitorTilt the monitor panel forward or backward to set it to a comfortable eye level.Figure 2-5 Tilting the MonitorTurning on the Monitor1.Press the power button on the computer to turn on the computer.2.Press the power button on the front of the monitor to turn on the monitor.should always activate a screen saver application or turn off the monitor when it is not in use for aprolonged period of time. Image retention is a condition that may occur on all LED screens. Monitorswith a “burned-in image” are not covered under the HP warranty.* A prolonged period of time is 12 consecutive hours of non-use.If pressing the power button has no effect, the power button lockout feature may be enabled.You can disable the power LED in the OSD menu. Press the Menu button on the front of theManagement > Bezel Power LED > Off.6Chapter 2 Setting Up the MonitorUsing the Accessory RailsThe monitor features accessory rails on the rear that can be used to mount optional devices, such asthe HP speaker bar, to attach to the monitor. Refer to the documentation included with the optionaldevice for detailed mounting instructions.Figure 2-6 Using the Accessory Rails FeatureMounting the Monitor PanelYou can remove the monitor panel from the pedestal base to install the panel on a wall, a swing arm(sold separately), or other mounting fixture. Four threaded mounting holes are provided on themonitor back panel to be used for mounting purposes.1.Disconnect and remove the signal and power cables from the back of the monitor.y the monitor face down on a flat surface covered by a dry, clean cloth.Using the Accessory Rails73.Remove the three screws from the back of the monitor that connect the monitor panel to thepedestal base (1) and slide the pedestal base from the monitor panel (2).Figure 2-7 Removing the Pedestal Base4.To attach the monitor to a swing arm (sold separately), insert four 10mm screws through theholes on the swing arm plate and into the mounting holes on the monitor.screws are required. Longer screws must not be used because they may damage the monitor. Itis important to verify that the manufacturer’s mounting solution is compliant with the VESAstandard and is rated to support the weight of the monitor display panel. For best performance, itis important to use the power and video cables provided with the monitor.Figure 2-8 Installing the Monitor on a Swing Arm (sold separately)To attach the monitor to other mounting fixtures, follow the instructions included with themounting fixture to ensure that the monitor is safely attached.5.Reconnect the cables to the monitor panel.8Chapter 2 Setting Up the MonitorLocating the Rating LabelsThe rating labels on the monitor provide the spare part number, product number, and serial number.You may need these numbers when contacting HP about the monitor model. The rating labels arelocated on the rear panel of the monitor.Figure 2-9 Locating the Rating LabelsInstalling a Cable LockYou can secure the monitor to a fixed object with an optional cable lock available from HP (soldseparately).Figure 2-10 Installing a Cable LockLocating the Rating Labels93Finding More InformationRefer to the HP LCD Monitors Reference Guide included on the CD with your monitor for additionalinformation on:●Optimizing monitor performance●Safety and maintenance guidelines●Installing software from the CD●Using the OSD menu●Downloading software from the Web●Agency regulatory information●Troubleshooting and recommended solutions to common problemsProduct SupportFor additional information on using and adjusting your monitor, go to /support.Select your country or region, select Product Support & Troubleshooting, and then enter yourmonitor model in the Search window.support.If the information provided in the guide or in the HP LCD Monitors Reference Guide does not addressyour questions, you can contact support. For U.S. support, go to /go/contactHP.For worldwide support, go to /country/us/en/wwcontact_us.html. Here you can:●Chat online with an HP technician●Find e-mail support●Find support telephone numbers●Locate an HP service center10Chapter 3 Finding More Information4Technical SpecificationsTable 4-1 P19A SpecificationsMaximum Weight (Unpacked) 3.47 kg7.65 lbsDimensions (include stand) HeightDepthWidth 41.82 cm20.64 cm41.40 cm16.46 inches8.13 inches16.3 inchesMaximum Graphic Resolution1280 x 1024 (60Hz) analog inputOptimum Graphic Resolution1280 x 1024 (60 Hz) analog inputPower Source100 – 240 VAC 50/60 HzInput Terminal One VGA connectorTilt–5° to 25°Operating Temperature5° to 35° C41° to 95° FOperating Altitude0 to 5,000 m0 to 16,400 ft.NOTE:For more information, go to /go/productbulletin and search for your specific display model to findthe model-specific QuickSpecs.Preset Display ResolutionsThe display resolutions listed below are the most commonly used modes and are set as factorydefaults. This monitor automatically recognizes these preset modes and they will appear properlysized and centered on the screenTable 4-2 Factory Preset ModesPreset Pixel Format Horz Freq (kHz)Vert Freq (Hz)1640 × 48031.4759.942720 × 40031.4770.093800 × 60037.8860.3241024 × 76848.3660.0051280 × 96060.0060.0061280 × 102463.9860.02Preset Display Resolutions11Entering User ModesThe video controller signal may occasionally call for a mode that is not preset if you are not using astandard graphics adapter.12Chapter 4 Technical Specifications。
100W isolated DC-DC converterUltra-wide input and regulated single outputCB Report RoHSCSA62368EN62368BS EN62368IEC62368-1EN50155EN45545FEATURES●Ultra-wide12:1input voltage range:14-160VDC●High efficiency up to90%●Reinforced insulation,I/O isolation test voltage3k VAC●Operating ambient temperature range-40℃to+105℃●Active hold-up control,programmable inputunder-voltage control●Input reverse polarity protection,Inputunder-voltage protection,output over-voltage,over-current,short-circuit protection,over-temperature protection●Industry standard1/4-Brick package●Design to meet AREMA standards●Design to meet UL62368standardsThe UWTH1D_QB-100W(H/F)R3series is a high-performance product specifically designed for a variety of railway applications.The output power can reach at100W.It features wide input voltage of14-160VDC,which is compatible with nominal input type of24V,48V,72V,96V and110V.Meets EN50155standard for voltage fluctuations.The reinforced high insulation3000V AC ensures that the system can still be used safely in5000m high altitude applications.The allowable operating temperature is up to105°C.It integrates multiple protection functions to ensure the safety and high reliability of the system,with functions of remote control and compensation,output voltage adjustment,etc., which perfectly matches the requirements of line loss and special voltage in the application.It is widely used in vehicle-mounted switches, train control systems and associated equipment.Selection GuideCertification Part No.①Input Voltage(VDC)Output Full LoadEfficiency(%)③Min./Typ.Max.CapacitiveLoad(µF)Nominal(Range)Max.②Voltage(VDC)Current(mA)(Max./Min.)CSA/EN/BS EN/IECUWTH1D12QB-100W(H/F)R3110(14-160)160128330/088/907000 UWTH1D15QB-100W(H/F)R3156670/04500UWTH1D24QB-100W(H/F)R3244160/087/891800 UWTH1D28QB-100W(H/F)R3283570/01300UWTH1D48QB-100W(H/F)R3482080/088/901000 UWTH1D54QB-100W(H/F)R3541850/0820 Note:①Use“F/H”suffix for heat sink mounting.We recommend to choose modules with a heat sink for enhanced heat dissipation and applications with extreme temperature requirements;②Exceeding the maximum input voltage may cause permanent damage;③Efficiency is tested at nominal voltage and full load at+25℃ambient;④When UWTH1D_QB-100W(H/F)R3series products input voltage is14V~16.8V,the converter can work100ms at full load.Input SpecificationsItem Operating Conditions Min.Typ.Max.Unit Input Current(full load)24V input voltage24V,28V output--47894902mA12V,15V,48V,54V output--4735484536V input voltage24V,28V output--3157323012V,15V,48V,54V output--3121319348V input voltage24V,28V output--2341239612V,15V,48V,54V output--2315236972V input voltage24V,28V output--1561159712V,15V,48V,54V output--1543157896V input voltage24V,28V output--1184121112V,15V,48V,54V output--11711197Patent ProtectionInput Current (full load)110V input voltage 24V,28V output--10331057mA12V,15V,48V,54V output--10221045Reflected Ripple Current Nominal input voltage--150--Surge Voltage (1sec.max.)-0.7--200VDC Start-up Voltage ----14Start-up Current Nominal 48input voltage,full load----5000mA Start-up Time Nominal input voltage,constant resistance load--50100ms Input Filter LC filterHot PlugUnavailableNo-load Input Power Ctrl pin open or pulled high,DC-DC ON (14-160VDC)-- 1.2 2.0WIdle Input Power Ctrl pin pulled low to -Vin,DC-DC OFF (14-160VDC)--0.71.6Ctrl①Module on Ctrl pin open or pulled high (3.5-12VDC)Module offCtrl pin pulled low to -Vin (0-1.2VDC)Input Under-voltage Protection 1011--VDCUVLO②Operating temperature range,UVLO pin open,module off 10----Operating temperature range,UVLO pin connect to -Vin,module off60----Note:①The Ctrl pin voltage is referenced to input -Vin;②The UVLO pin voltage is referenced to input -Vin,please refer to Fig.9.Output SpecificationsItemOperating ConditionsMin.Typ.Max.Unit Voltage Accuracy Nominal input voltage,0%-100%load----±2%Linear Regulation Input voltage variation from low to high at full load --±0.2±0.5Load Regulation Nominal input voltage,10%-100%load --±0.5±1Transient Recovery Time 25%load step change @25℃----500µs Transient Response Deviation --±3±5%Temperature Coefficient Nominal output voltage,full load ----±0.03%/℃Ripple &Noise ①20MHz bandwidth,10%-100%load--150300mVp-p Trim 90--110%Vo Sense----105Over-temperature Protection Max.Case Temperature --115125℃Over-voltage Protection Input voltage range (14-160V)110--160%Vo Over-current Protection 105160260%IoShort-circuit ProtectionHiccup,continuous,self-recoveryNote:①The “Tip and barrel method”is used for ripple and noise test,for details please refer to Fig.3.General SpecificationsItem Operating Conditions Min.Typ.Max.UnitIsolationElectric Strength Test for 1minute with a leakage current of 5mA maxInput-output 3000----V AC Input-case 2500----Output-case2100----Insulation Resistance Input-output resistance at 500VDC 1000----M ΩIsolation Capacitance Input-output capacitance at 100KHz/0.1V--1100--pF Operating Temperature -40--105℃Storage Temperature -55--125Pin Soldering Resistance TemperatureSoldering spot is 1.5mm away from case for 10seconds ----300Storage Humidity Non-condensing 5--95%RH Switching Frequency PWM mode --175--KHz MTBF IEC 61709@25℃1000----k hours Cooling Test EN60068-2-1Dry Heat EN60068-2-2Damp HeatEN60068-2-30Shock and Vibration Test IEC/EN61373Class B Pollution Level PD3Fire&Smoke Compliance EN45545-2,HL3 Salt Mist Test EN60068-2-11,Ka Cyclic Damp Heat Test EN60068-2,Db variant2 Altitude①5000mLow Temperature Start-up andStorage Test EN60068-1,Ad and Ab Note:①When the altitude is above2000m,the product surface max.temperature must be below105℃.Mechanical SpecificationsCase Material Aluminum alloy case;Black plastic bottom,flame-retardant and heat-resistant(UL94V-0)Dimension Without heat sink57.90x36.80x12.70mm With H heat sink57.90x36.80x25.40mm With F heat sink62.00x56.00x14.50mmWeight Without heat sink79.5g(Typ.) With H heat sink109.5g(Typ.) With F heat sink99.5g(Typ.)Cooling Method Conduction cooling or forced air coolingFree air convection cooling with additional heat sink Electromagnetic Compatibility(EMC)(EN50121-3-2)Emissions CEEN50121-3-2EN55016-2-1150kHz-500kHz99dBuV(see Fig.6for recommended circuit)500kHz-30MHz93dBuV(see Fig.6for recommended circuit)EN55032EN55032-11150kHz-500kHz79dBuV(see Fig.6for recommended circuit)500kHz-30MHz73dBuV(see Fig.6for recommended circuit) RE CISPR16-2-330MHz-230MHz40dBuV/m at10m(see Fig.6for recommended circuit)230MHz-1GHz47dBuV/m at10m(see Fig.6for recommended circuit)1GHz-6GHz47dBuV/m at10m(see Fig.6for recommended circuit)Immunity ESD EN61000-4-2Contact±6kV/Air±8kV perf.Criteria A RS EN61000-4-380–800MHz20V/m800–1000MHz20V/m1400–2000MHz10V/m2000–2700MHz5V/m5100–6000MHz3V/mperf.Criteria A EFT EN61000-4-4±2kV5/50ns5kHz(see Fig.6for recommended circuit)perf.Criteria A Surge EN61000-4-5line to line±1kV(42Ω,0.5μF)line to ground±2kV(42Ω,0.5μF)(see Fig.6for recommended circuit)line to line±1kV(2Ω,18μF)line to ground±2kV(12Ω,9μF)(see Fig.6for recommended circuit)perf.Criteria A CS EN61000-4-60.15MHz-80MHz10V r.m.s perf.Criteria AElectromagnetic Compatibility(EMC)(AREMA)Emissions CECISPR16-2-1150kHz-500kHz79dBuV(see Fig.6for recommended circuit)CISPR16-1-2500kHz-30MHz73dBuV(see Fig.6for recommended circuit)RE CISPR16-2-330MHz-230MHz230MHz-1GHz40dBuV/m at10m(see Fig.6for recommended circuit)47dBuV/m at10m(see Fig.6for recommended circuit)Immunity ESD IEC61000-4-2Contact±6kV/Air±8kV perf.Criteria ARS IEC61000-4-380–1000MHz10V/m160–165MHz20V/m450–470MHz20V/m800–960MHz20V/m1400–2000MHz20V/m2100–2500MHz5V/mperf.Criteria AEFT IEC61000-4-4±2kV5/50ns5kHz(see Fig.6for recommended circuit)perf.Criteria A Surge IEC61000-4-5line to line±2kV(2Ω,18μF)line to ground±2kV(12Ω,9μF)(see Fig.6for recommended circuit)perf.Criteria A CS IEC61000-4-60.15MHz-80MHz10V r.m.s perf.Criteria AMS IEC61000-4-860Hz100A/m(see Fig.6for recommended circuit)perf.Criteria A 60Hz300A/m(see Fig.6for recommended circuit)Typical Performance CurvesRemote Sense Application1.Remote Sense Connection if not usedFig.1Notes:(1)If the sense function is not used for remote regulation the user must connect the+Sense to+Vo and-Sense to-Vo.(2)The connections between Sense lines and their respective power lines must be kept as short as possible,otherwise they may be picking up noise,interference and/or causing unstable operation of the power module.2.Remote Sense Connection used for CompensationFig.2Notes:(1)Using remote sense with long wires may cause unstable output,please contact technical support if long wires must be used.(2)PCB-tracks or cables/wires for Remote Sense must be kept as short as possible.Twisted pair or shielded pairs are suggested for remote compensation and must be kept as short as possible.(3)We recommend using adequate cross section for PCB-track layout and/or cables to connect the power supply module to the load in order to keep the voltage drop below0.3V and to make sure the power supply's output voltage remains within the specified range.(4)Note that large wire impedance may cause oscillation of the output voltage and/or increased ripple.Consult technical support or factory for further advice of sense operation.Design ReferenceAll the DC-DC converters of this series are tested before delivery using the recommended circuit shown in Fig.3.Fig.3CapacitorsvalueOutput voltageC0(µF)C1(µF)C2(µF) 12VDC100µF,voltage≥200V1µF,voltage≥1.2*Vo330µF,voltage≥1.2*Vo 15VDC24VDC28VDC48VDC54VDC2.Typical application1.Mornsun EMC circuit is recommended,otherwise please ensure that at least a100µF electrolytic capacitors is connected at the input in order to ensure adequate voltage surge suppression and protection.2.Output ripple can be further reduced by appropriately increasing the output capacitor values C3and/or by selecting capacitors with a low ESR(equivalent series resistance).Also make sure that the capacitance is not exceeding the specified max.capacitance load value of the product.3.The UVLO pin can adjust the point of input under-voltage protection by the external resistance RUVLO.Please refer to Fig.9for the value of RUVLO,if the pin is left open,the under-voltage protection point is11V.4.Ctrl current-mode logic recommended circuit design refer to fig.4.Fig.4Components Value Recommended Component R010K--C30.1µF voltage≥25VQ1Ic≥10mA voltage≥30V Note:S1pin open,DC-DC ON.3.Trim Function for Output Voltage Adjustment (open if unused)Fig.5Trim resistor connection (dashed line shows internal resistor network)Calculation formula of Trim resistance:322T R a R R *a =R :up Trim -- 2.5-Vo R *2.5=a 1311T *=R :down Trim R bR R b --5.2R *)5.2o V (=b 2-Note :a ,b:self-defined parameter ,round to the nearest hundredth R T [k Ω]:Resistance of Trim.Vo:Output voltage change.V ref [VDC]:Reference voltage.Vo Res 12(VDC)15(VDC)24(VDC)28(VDC)48(VDC)54(VDC)R1(K Ω)1114.3524.828.85461R2(K Ω) 2.87 2.87 2.87 2.87 2.94 2.94R3(K Ω)20.220.223.123.118.218.2Practical Example trim up -10%for 12V output:53.9=5.287.2*)5.28.10(=b -ΩK 113.51=2.2053.91111*53.9=R T --R T according to E24≈51k ΩPractical Example trim up +10%for 12V output:57.2=5.22.1311*5.2=a -ΩK 386.4=2.2057.287.287.2*57.2=R T --R T according to E24≈4.3k Ω4.EMC compliance circuit1.The anti-reverse connection circuit is composed of a circuit breaker and a diode D1.The withstand voltage of the diode D1mustbe greater than 250V;2.The EMC filter part is composed of modular circuits.Please refer to Figure 6for recommended circuits and parameters.Self-built circuits can also be used;3.Resistor RUVLO is used to adjust the input under-voltage protection point.Refer to Figure 9for the value.Fig.6Matching Power output voltageC omponents ValueC4C2C1CY4,CY5,CY6D112V 330µFVoltage ≥200V330µFVoltage ≥1.2*Vo1µFVoltage ≥1.2*Vo3300pF /400V AC Y1safety capacitor20AVoltage ≥200V15V 24V 560µFVoltage ≥200V28V 48V 54V BreakerThe Breaker value varies with different power modules and must be selected in accordance with the specified input current of the corresponding power converter,but not exceeding the filter specifications.Note:A ferrite core on the power lines and load lines can ensures a better EMI test margin.EMC FilterComponentsValue Recommended ComponentC60.1µF Voltage ≥630V C80.22µF Voltage ≥250V C9 2.2µF Voltage ≥250V LCM1≧2mH FL2D-A2-202LCM2≧4mH COMMON MODE,≧4mH,35m Ω,-40to +125℃Ø1.2mm×24Ts LDM10.47µH Shielding Inductive LDM2150µH Differential MODE,150uH ±35%,30m Ω,-40to +125℃Core T10*6*4,Ø0.5mm×25TsCY1,CY22200pF /400V AC Y1safety capacitor CY31000pF /400V ACY1safety capacitorMOV17D221KVaristorNote:The emc filter recommended to use MORNSUN P/N:FC-C08D.Surge standardComponentsValue Recommended Component line to line ±1KV (42Ω,0.5μF)line to ground ±2kV (42Ω,0.5μF)C0100µF Voltage ≥250VC10,C11----line to line ±1KV (2Ω,18μF)line to ground ±2kV (12Ω,9μF)C0,C10100µF Voltage ≥250VC11----line to line ±2KV (2Ω,18μF)line to ground ±2kV (12Ω,9μF)C0,C10,C11100µFVoltage ≥250V5.Hold-up time setup capacitorFig.7Recommended circuit and PCB layout for hold-up timeThe hold-up time capacitor CExt.Cap is used to hold the output when the input power off.Note:1.If there is no requirement for the hold-up time,no additional capacitor CExt.Cap is required;2.For the hold-up time of 10ms and 30ms,please refer to table blow;3.Vq is Start-up voltage.Po (W)100Vin (V)2436487296110V q (V)13.219.526.940.353.461.1C Ext.Cap (µF)△t:10ms470470470470470470△t:30ms1410141014101410141014106.Recommended circuit for multi-module parallel redundant designFig.8Note:1.The function of capacitor C1,C2is filtering.It is used for margin design and cannot be used to increase power;2.The diodes D2and D3are used to protect the power module.In actual use,the user can choose the parameters of the diode or MOSFET according to the output current;3.Because the output impedance of the two modules is different,the output power of each module cannot be guaranteed to be equal;Pload =P1+P2<Pmax (100W).7.UVLO Function and R UVLO ValuesThe products with an ultra-wide input voltage range,covering a variety of nominal input voltages.Set the input under-voltage point adjustable function for different input systems,connect a resistor between UVLO pin and -Vin,adjust the under-voltage point of the product by adjusting the resistor value.Fig.9UVLO values for various nominal input voltage and R UVLO tableNominal input voltage (V)2436487296110Starting Voltage (V)13.219.526.940.353.461.1Shutdown Voltage (V)11.216.723.334.846.353.1UVLO setup resistance (K Ω)open15056.118.35.61.5UVLO setup calculation100nF/50V/0805Calculation formula of R UVLO setup resistance :20-c-182c*182=R UVLO 6.45-V 1272.35=c shutdown Note:c:self-defined parameter.R UVLO (K Ω):UVLO setup resistance.V shutdown:UVLO shutdown voltage.8.For additional information please refer to DC-DC converter application notes on Dimensions and Recommended Layout(without heat sink)Note:1.For additional information on Product Packaging please refer to .Packaging bag number:58010113(UWTH1DxxQB-100WR3);58220017(UWTH1DxxQB-100WHR3);58200069(UWTH1DxxQB-100WFR3);2.The maximum capacitive load offered were tested at input voltage range and full load;3.Unless otherwise specified,data in this datasheet should be tested under the conditions of Ta=25℃,humidity<75%RH with nominal inputvoltage and rated load;4.All index testing methods in this datasheet are based on our company corporate standards;5.Product customization is available,please contact below email directly for specific needs;6.Products are related to laws and regulations:see"Features"and"EMC";7.Our products shall be classified according to ISO14001and related environmental laws and regulations,and shall be handled byqualified units.Mornsun Guangzhou Science&Tech nolo gy Co.,Ltd.Address:No.5,Kehui St.1,Kehui Development Center,Science Ave.,Guangzhou Science City,Huangpu District,Guangzhou,P.R.ChinaTel:86-20-38601850Fax:86-20-38601272E-mail:***************。
©2022 Bose Corporation. All rights reserved. The Mountain, Framingham, MA 01701-9168 USA, All trademarks are the property of their respective owners AM772964 Rev. 01Limited WarrantyY our product is covered by a limited warranty, Visit for warranty details.Importer InformationChina Importer: Bose Electronics (Shanghai) Company Limited, Level 6, T ower D, No. 2337 Gudai Rd. Minhang District, Shanghai 201100UK Importer: Bose Limited Bose House, Quayside Chatham Maritime, Chatham, Kent, ME4 4QZ, United KingdomEU Importer: Bose Products B.V ., Gorslaan 60, 1441 RG Purmerend, The NetherlandsMexico Importer: Bose de México, S. de R.L. de C.V . , Paseo de las Palmas 405-204, Lomas de Chapultepec, 11000 México, D.F . For importer & service information: +5255 (5202) 3545T aiwan Importer: Bose T aiwan Branch, 9F-A1, No. 10, Section 3, Minsheng East Road, T aipei City 104, T aiwan. Phone Number: +886-2-2514 7676Safety InformationCAUTION: This product is intended for installation by professional installers only! PRECAUCIÓN: Solo un instalador profesional deberá montar este producto! ATTENTION: L’installation de ce produit est réservée à un technicien professionnel! ACHTUNG: Dieses Produkt darf nur von fachkundigen Monteuren installiert werden!CAUTION: Make no modification to system or accessories. Unauthorized alterations may compromise safety, regulatory compliance, and sys-tem performance. PRECAUCIÓN: No realice alteraciones no autorizadas a este producto; esto podría comprometer la seguridad, el cumplimiento de las normas y el rendimiento del sistema. ATTENTION: Ne pas faire des modifications non autorisées à ce produit; ce qui pourrait compromettre la sécurité, la conformité réglementaire et la performance du système. ACHTUNG: Keine nicht autorisierten Veränderungen am Produkt vornehmen. Diese können die Sicherheit, die Einhaltung von Richtlinien und die Systemleistung beeinträchtigen.CAUTION This accessory is intended for use with Bose ShowMatch DeltaQ Array loudspeakers only. PRECAUCIÓN: Este accesorio está diseñado para usarse únicamente con altavoces Bose ShowMatch DeltaQ Array. ATTENTION: Cet accessoire est destiné pour l’usage avec les haut-parleurs Bose ShowMatch Delta Q exclusivement. ACHTUNG:Dieses Zubehör ist ausschließlich zur Verwendung mit Bose ShowMatch DeltaQ Array Lautsprechern vorgesehen.Additional InformationFor additional information on ShowMatch DeltaQ Array loudspeaker modules and accessories, refer to the installation guide available at . T o request a printed copy, use the phone numbers provided.Contact InformationBose Corporation The Mountain Framingham, MA 01701 USACorporate Center: 508-879-7330 Americas Professional Systems, Technical Support: 800-994-2673To install the short quick pins, follow these instructions:1. Remove side end caps and tethered standard quick pins that are factory-installed on each loudspeaker module. See Fig. 1. For detailed instructions, see ShowMatch DeltaQ Array Loudspeaker Installation Guide on .2. Align pin in appropriate location on array assembly.3. Insert non-threaded end of tool into the top of the pin to press the button and insert the pin. The top of the pin should insert until flush with array assembly. See Fig. 2.4. T o remove the pin, screw threaded end of tool into the top of the pin, where the button is located. See Fig. 3.5. This presses the button to release the pin and provides a grip handle to allow the pin to be removed. See Fig. 4.Installation InformationThank you for selecting Bose ShowMatch DeltaQ array loudspeakers. This document is intended to provide professional installers with basic installation and safety guidelines for using the optional short quick pin accessory with ShowMatch loudspeakers. Please read this document before attempting installation.Each ShowMatch DeltaQ full-range array module (SM5, SM10, and SM20) and subwoofer module (SMS118) includes standard installation pins. Use the short quick pins (SMQPS) in place of the standard pins to reduce the width of the array assembly.Short quick pins and installation toolFig. 2. Insert pin using non-threaded end of tool Fig. 3. Remove pin using threaded end of tool Fig. 4. Use tool to remove pin Fig. 1. Remove loudspeaker module end caps。
PAGE 1 SNAP-SCM-CAN2B MODULEFeaturesTransmits and receives data packets on a Controller AreaNetworkCan be configured to encode data as ASCII Hex with framedelimitingStandard top-mounted connector for easy wiringBaud rates to 1 MbpsUp to eight SNAP-SCM-CAN2B modules per rackPAC Project integration kit available30-month warrantyUL approvedDESCRIPTIONThe SNAP-SCM-CAN2B serial communications module can transmit and receive data on a Controller Area Network (CAN).When transmit functionality is enabled, all transmit and receive data passed between the module and the SNAP PAC brain or controller over Ethernet is ASCII encoded and frame delimited for robust communications.The SNAP-SCM-CAN2B module is designed for use with Opto22’s SNAP PAC R-series controllers and SNAP PAC EB-series brains, both the standard wired models and the Wired+Wireless™ models. The brain or controller processes the data from the module and can communicate the data to other parts of an Opto 22 SNAP PAC System™ or to another system (such as a Modbus® system or an OPC client).NOTE: The R-series controller or EB-series brain must have firmware version 9.2a or newer. This module does not work with legacy brains or controllers. The SNAP-SCM-CAN2B module snaps into Opto22 SNAP PAC mounting racks, right beside other SNAP I/O modules, to provide the mix of analog, digital, and serial channels you need at any location. It uses the standard SNAP removable top-mounted connector for easy wiring. LEDs indicate CAN bus activity on the port, as well as power and operation status.SNAP racks have a retention rail locking system. Use two 4-40 by½-inch standard machine screws to hold each module securely in position on the SNAP rack.ConfigurationConfiguration of the SNAP-SCM-CAN2B module to transmit and receive data is normally done in PAC Control using sample subroutines from the Opto22 CAN RX/TX Integration Kit for PAC Project™ (part number PAC-INT-CAN-RXTX, a free download from our website).Using PAC Control, you add the integration kit’s sample subroutines into your PAC Control strategy. By modifying the samples as necessary, your Opto22 SNAP PAC System (equipped with one or more SNAP-SCM-CAN2B modules) can transmit data from a CAN network and receive data with encoding and frame delimiting.For information on using the integration kit, see form 2151, the CAN RX/TX Integration Kit for PAC Project Technical Note.If you wish, you can also use PAC Manager for configuration.For information on installing and configuring the module in PAC Manager, see form 1191, Serial Communications Module User’s Guide. PAC Project Basic (including PAC Control and PAC Manager) comes on a CD with every SNAP PAC brain and controller. Both PAC Project and the integration kit are also available for download from the Product section of our website, .>>>>>>>>Part NumbersPart DescriptionSNAP-SCM-CAN2B Serial communication module for transmitting and receiving CAN packetsPAC-INT-CAN-RXTX CAN RX/TX Integration Kit for PACProjectSNAP-SCM-CAN2B ModuleOPTO 22PAGE 2OPTO 22•800-321-6786•1-951-695-3000••****************DATA SHEETForm 1537-221026Backward CompatibilityThe SNAP-SCM-CAN2B was originally issued as a receive-only module but as of May 2015 includes transmit capability as well. Default behavior is still receive only; to also transmit you just need to configure the module in PAC Control or PAC Manager.To add transmit capability to a module with older firmware, update the module’s firmware to version R2.0b or higher. The new SNAP-SCM-CAN2B firmware is available on the Opto 22 website (follow the link or click the Support tab, choose Downloads, and filter by Firmware). For steps to update firmware, see the PAC Manager User’s Guide .PINS FOR EACH PORTPins 1-4 are in parallel to pins 5-8. V+ is not used by the module. See diagram on page 4 for location of pin 1.For complete installation information, see form 1191, the SNAP Serial Communication Modules User’s Guide .BUFFERSThe SNAP-SCM-CAN2B has two buffers, transmit and receive, that are 8192 bytes each, regardless of the mode (transmit and receive or receive only). If transmit is enabled (which implies ASCII Hex encoding and frame delimiting) then packet sizes range from 9–29 bytes, which translates to a buffer storing 282 to 910 CAN packets. In receive-only mode packet sizes are from 6–13 bytes and a buffer can store 613 to 1365 CAN packets. If the buffer is full and a new packet is received, the oldest packet will be dropped from the buffer.Modules now sold with transmit capability built in are backwards compatible with older module firmware version R1.0d. If you are using a new module in a PAC Control strategy designed for the older module, you should not need to change your strategy unless you want to use the transmit capability.Integration kits. There are two integration kits:•PAC-INT-CAN-RXTX is the new integration kit that includes sample subroutines and charts for transmitting and receiving CAN data. Use this integration kit for modules with firmware version R2.0b or higher.•PAC-INT-CAN-RX (formerly PAC-INT-CAN) is the older kit that includes sample charts only for receiving CAN data. Use this kit only for modules with firmware R1.0d and lower.SPECIFICATIONSPin Use 1,5V +2,6CAN +3,7CAN –4,8GNDBaud rates10–1000 Kbps*Logic supply voltage 5.0 VDC Logic supply current 250 mA DC Number of ports per module 1Max. number of modules per rack**8Processor compatibility SNAP PAC R-series controllers and SNAP PAC EB brains, both standard wired and Wired+Wireless models, with firm-ware 9.2a or newer.Operating temperature -20 to 70 °C Storage temperature -30 to 85 °CTorque, hold-down screws Not to exceed 1 in-lb (0.11 N-m)Torque, connector screws 5.22 in-lb (0.59 N-m)Agency Approvals UL, CE, FM, RoHS, DFARS Warranty30 months from date of manufacture* Module performance is limited by the number of serial modules on the SNAP rack. Each rack backplane pro-vides approximately 2.5 Mbps of bandwidth.** Maximum number of modules per rack assumes a 4A power supply (for example, SNAP-PS5).OPTO 22•800-321-6786•1-951-695-3000••****************PAGE 3DATA SHEETForm 1537-221026LEDsError LED Operation. The #4 LED indicates an error on the CAN bus. Error codes include:To clear the error, you can use PAC Manager or PAC Control to read the CAN module configuration from the memory map. (For the memory map addresses required to access the error codes, see form 1465, OptoMMP Protocol Guide , Appendix A: SNAP-SCM-CAN2B Serial Module Configuration-Read/Write.)If your device has SNAP-SCM-CAN2B Firmware R2.0b or higher , the Error LED also illuminates when any bits are set in either the CAN bus error flags register or the CAN transport error flags register. For information on error flags, see form 2151, the CAN RX/TX Integration Kit for PAC Project Technical Note , “CAN Module Status Reply.”In addition to clearing the error by reading from the memory map, with firmware R2.0b, you can also clear the error by issuing an “S” command from the O22Can2BModuleCtrlStat subroutine (in the CAN Integration Kit for PAC Project ). For more information, see form 2151, the CAN RX/TX Integration Kit for PAC Project Technical Note, “PAC Control Sample Subroutines.”LED Type Indicates1CAN Bus ActivityCommunication activity with the CAN module. This LED illuminates while the mod-ule is being configured and when CAN data is received.2STATUS 2 blinks: SNAP-SCM-CAN2B firmware has started.5 blinks: firmware error 8 blinks: CAN module error 3POWER Power is applied to the module.4ERRORError on the CAN bus. (For details, see next section.)Error CodesDescription0Error—Active State. The SNAP-SCM-CAN2B has received less than 96 errors.-1Error—Active State. The SNAP-SCM-CAN2B has received 96 or more errors but less than 128 errors.-2Receiver Overflow. A CAN packet was dropped. This happens when theSNAP-SCM-CAN2B can't keep up with the traffic on the CAN bus. This means the internal buffer on the CAN2B module is full. This can happen if the strategy isn't reading the data fast enough, or too many serial modules are on the rack. To resolve it, you can:• Configure the Data Masks and Filters to receive fewer CAN packets.•Reduce the number of serial modules on the rack.•Increase how frequently the strategy reads the module.-3Error—Passive State. The SNAP-SCM-CAN2B has received 128 or more errors but less than 255 errors.PAGE 4OPTO 22•800-321-6786•1-951-695-3000••****************DATA SHEETForm 1537-221026DIMENSIONSPin 1OPTO 22 • SALES •****************SUPPORT •******************43044 Business Park Dr. Temecula, CA 92590-3614800-321-6786 • 1-951-695-3000800-835-6786 • 1-951-695-3080More about Opto 22Form 1335-220705PRODUCTSOpto 22 develops and manufactures reliable, easy-to-use, open standards-based hardware and software products. Industrial automation, process control, remote monitoring, data acquisition, and industrial internet of things (IIoT) applications worldwide all rely on Opto 22.groov RIO ®groov RIO edge I/O offers a single, compact, PoE-powered industrial package with web-based configuration and IIoT software built in, support for multiple OT and IT protocols, and security features like a device firewall, data encryption, and user account control.Standing alone, groov RIO connects to sensors, equipment, and legacy systems, collecting and securely publishing data from field to cloud. Choose a universal I/O model with thousands of possible field I/O configurations, with or without Ignition from Inductive Automation®, or a RIO EMU energy monitoring unit that reports 64 energy data values from 3-phase loads up to 600 VAC, Delta or Wye.You can also use groov RIO with a Modbus/TCP master or as remote I/O for a groov EPIC system.groov EPIC ® SystemOpto 22’s groov Edge Programmable Industrial Controller (EPIC) system gives you industrially hardened control with a flexible Linux®-based processor with gateway functions, guaranteed-for-life I/O, and software for your automation and IIoT applications.groov EPIC ProcessorThe heart of the system is the groov EPIC processor. It handles a wide range of digital, analog, and serial functions for data collection, remote monitoring, process control, and discrete and hybrid manufacturing.In addition, the EPIC provides secure data communications among physical assets, control systems, software applications, and online services, both on premises and in the cloud. No industrial PC needed.Configuring and troubleshooting I/O and networking is easier with the EPIC’s integrated high-resolution color touchscreen. Authorized users can manage the system locally on the touchscreen, on a monitor connected via the HDMI or USB ports, or on a PC or mobile device with a web browser.groov EPIC I/Ogroov I/O connects locally to sensors and equipment. Modules have a spring-clamp terminal strip, integrated wireway, swing-away cover, and LEDs indicating module health and discrete channel status. groov I/O is hot swappable, UL Hazardous Locations approved, and ATEX compliant.groov EPIC SoftwareThe groov EPIC processor comes ready to run the software you need:•Programming: Choose flowchart-based PAC Control, CODESYS Development System for IEC61131-3 compliantprograms, or secure shell access (SSH) to the Linux OS for custom applications •Node-RED for creating simple IIoT logic flows from pre-built nodes•Efficient MQTT data communications with string or Sparkplug data formats •Multiple OPC UA server options•HMI: groov View to build your own HMI viewable on touchscreen, PCs, and mobile devices; PAC Display for aWindows HMI; Node-RED dashboard UI•Ignition or Ignition Edge® from Inductive Automation (requires license purchase) with OPC-UA drivers to Allen-Bradley®,Siemens®, and other control systems, and MQTT communicationsOlder productsFrom solid state relays, to world-famous G4 and SNAP I/O, to SNAP PAC controllers, older Opto 22 products are still supported andworking hard at thousands of installations worldwide. You can count on us for the reliability and service you expect, now and in the future.QUALITYFounded in 1974, Opto 22 has established a worldwide reputation for high-quality products. All are made in the U.S.A. at our manufacturing facility in Temecula, California.Because we test each product twice before it leaves our factory rather than testing a sample of each batch, we can afford to guarantee most solid-state relays and optically isolated I/O modules for life.FREE PRODUCT SUPPORTOpto 22’s California-based Product Support Group offers freetechnical support for Opto 22 products from engineers with decades of training and experience. Support is available in English and Spanish by phone or email, Monday–Friday, 7a.m. to 5 p.m. PST.Support is always available on our website, including free online training at OptoU, how-to videos , user’s guides , the Opto 22 KnowledgeBase, and OptoForums .PURCHASING OPTO 22 PRODUCTSOpto 22 products are sold directly and through a worldwide network of distributors, partners, and system integrators. For more information, contact Opto 22 headquarters at 800-321-6786 (toll-free in the U.S. and Canada) or +1-951-695-3000, or visit our website at .。
Certificate of AnalysisTakara Bio USA, Inc.2560 Orchard Parkway, San Jose, CA 95131, USAU.S. Technical Support: *******************************United States/Canada 800.662.2566 Asia Pacific+1.650.919.7300Europe+33.(0)1.3904.6880Japan+81.(0)77.565.6999Page 1 of 1(041023) SeqAmp™ CB PCR BufferCatalog No. Amount Lot Number638526 50 rxns Specified on product label.DescriptionSeqAmp CB PCR Buffer is designed for improved compatibility with DNA purification using Agencourt AMPure beads after amplification with SeqAmp DNA Polymerase and works with SMARTer® next-generation sequencing kits. Package Contents• 1.25 ml SeqAmp CB PCR Buffer (2X)Storage Conditions•Store at –20°C.Expiration Date•Specified on product label.Shipping Conditions•Dry iceProduct DocumentsDocuments for our products are available for download at /manualsThe following documents apply to this product:•SMARTer Stranded Total RNA-Seq Kit v2 - Pico Input Mammalian User Manual•SMART-Seq v4 Ultra Low Input RNA Kit for Sequencing User ManualQuality Control DataPCR TestSeqAmp DNA Polymerase with the SeqAmp CB PCR buffer performed well when used to amplify: •Fragments from a human genomic DNA template (12, 20, 24.1, 27 & 30 kb)•Fragments from a human genomic DNA template with high GC or AT content (0.5 kb with 75.4% GC, 4 kb with63.1% GC, 0.5 kb with 64.3% AT, and 4 kb with 61.8% AT)It is certified that this product meets the above specifications, as reviewed and approved by the Quality Department.CATALOG NO.638526NOTICE TO PURCHASER:Our products are to be used for Research Use Only . They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval.Your use of this product is also subject to compliance with the licensing requirements, listed below if applicable, and described on the product´s web page at . It is your responsibility to review, understand and adhere to any restrictions imposed by these statements.TRADEMARKS:©2023 Takara Bio Inc. All Rights Reserved.All trademarks are the property of Takara Bio Inc. or its affiliate(s) in the U.S. and/or other countries or their respective owners. Certain trademarks may not be registered in all jurisdictions.。
DimensionsW x D x H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .660 mm x 650 mm x 725 mm ( 26 in x 26 in x 29 in)Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103 kg (227 lb)Operating EnvironmentTemperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 – 35 °C Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 – 80%, non-condensing Altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3048 m (10,000 ft) max Heat Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4092 BTU/h Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1200 VA max Power Input Requirements . . . . . . . . . . . . . . . . . . . .100 – 240 V ~, 50 – 60 Hz User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Integrated LCD touchscreen Adapter/Ports■■Ethernet on RJ45 port ■■RS232 on DB9 port■■External DVI-I connectors (with VGA)■■ 6 External USB portsLiquid Waste Handling■■ 2 external waste bottles (5 L each)■■Can be connected to a laboratory drain Printing Options■■On-screen result review ■■Electronic printing to PDF ■■External printer (available)Required Maintenance■■Empty waste bottles (as needed)■■Clean surfaces, touchscreen, and racks (as needed)■■Perform the Clean System procedure (2 minute automated process, every 30,000 tests)LIS Specifi cations■■Bi-directional capability with broadcast download of test orders ■■Option to add patient demographics to printed results ■■LIS result output with option to include comment record ■■Chromatogram PDF can be sent automatically to a network folderD-100™ HbA 1c Elution Buffer A Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2600 mL Number of Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 1100 tests per bottle Storage Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 – 35°C Onboard Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 bottles D-100™ HbA 1c Elution Buffer B Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1400 mL Number of Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 3000 tests per bottle Storage Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 – 35°C Onboard Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 bottles D-100™ Wash Solution Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3300 mL Number of Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 1100 tests per bottle Storage Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 – 35°C Onboard Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 bottles D-100™ HbA 1c Analytical CartridgeNumber of Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10,000Storage Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 – 8°C Onboard Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 cartridge D-100™ HbA 1c Calibrator Pack Calibration Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .once per cartridge Storage Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 – 8°C D-100™ Prefi ltersNumber of Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,000Storage Requirements . . . . . . . . . . . . . . . . . . . . . .2 – 8°C, 120 days at 15 – 35°C Onboard Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 prefi lterGeneral Specifi cationsConsumable SpecificationsHbA1c Testing for DiabetesD-100™ Hemoglobin Testing SystemFor further information, please contact the Bio-Rad office nearest you or visit our website at /diagnosticsClinical Diagnostics Group Web site /diagnostics USA 180****6723Australia 61 2 9914 2800 Austria 43 1 877 8901 Belgium 32 03 710 53 00Brazil 55 31 3689 6600 Canada 151****4372China 86 21 61698500 Czech Republic 420 241 430 532 Denmark 45 4452 1000 Finland 358 9 804 22 00 France 33 1 47 95 60 00 Germany 49 0 89 318 840 Greece 30 210 7774396 Hong Kong 852 2789 3300 Hungary 36 1 459 6100 India 180****1224 Israel 972 3 9636050 Italy 39 02 216091 Japan 81 3 6361 7070 Korea 82 2 3473 4460 Mexico 52 55 5488 7670 The Netherlands 31 318 540666 New Zealand 64 9 415 2280 Norway 47 23 38 41 30 Poland 48 22 3319999 Portugal 351 21 472-7700 Russia 7 495 721 1404 Singapore 65 6415 3170 South Africa 27 11 442 85 08 Spain 34 91 590 5200 Sweden 46 8 555 127 00 Switzerland 41 0 26 674 55 05 06 Taiwan 886 2 2578 7189Thailand 662 651 8311 United Kingdom 44 0 20 8328 2000Bio-RadLaboratories, Inc.© 2016 Bio-Rad Laboratories, Inc. Printed in USA DG16-0012 A-318 Rev. 07/2016Printed on recycled paperwith soy-based inksD-100™ Hemoglobin Testing SystemSample Handling SpecificationsSample Throughput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80 tests/hour Time to First Result . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 minutes, 15 seconds Sample Analysis Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 seconds Sample Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .None required Sample Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 samples, continuous loading Stat Area Sample Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 samples (primary tube or microvial) Minimum Sample Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 mL (13 x 75 mm primary tube) Specimen Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Whole blood, capillary** Whole Blood Sample Aspiration Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 μL Prediluted Sample Aspiration Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .495 μL Acceptable Sample Tube Types■■K2-EDTA■■K3-EDTA■■Potassium Oxalate/Sodium Fluoride■■Sodium Citrate ■■Sodium Heparin ■■Lithium HeparinSupported Barcode Symbologies■■Code 39■■Code 128■■Codabar■■Interleaved 2 of 5■■EAN■■UPCPerformance SpecificationsTotal Precision* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≤1 .7% CV (NGSP units) Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Total Error <6% Linear Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 .5% – 20% HbA1c Minimum QC Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Once per day Sample Concentration Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50,000 – 350,000 mAU HbA1c Units Reported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IFCC and NGSP Hemoglobin Interferences■■No interference from hemoglobins S, C, D, or E ■■No interference from fetal hemoglobin up to 30%■■No interference from labile HbA1c■■No interference from carbamylated hemoglobin* Total precision is based on a 3-instrument, 60-day precision study using 3 lots of reagents to generate a total of 720 data points per sample . It includes the following sources of variation: within-run (repeatability), between-run, between-day, between-instrument, and between-lot .** Not available in US for the capillary collection kit .。
StarTool ® IOO 3.1 Patch 6 ReadmeJune 2022This Readme file contains information for StarTool IOO patch release 3.1 Patch 6.The StarTool IOO 3.1 Patch 6 patch release contains only the changes that have been made to product files since StarTool IOO 3.1.5. See “Installation Considerations” on page 4 for instructions on downloading and installing the StarTool IOO 3.1 Patch 6 patch release.General InformationProduct DescriptionStarTool ® Input/Output Optimizer (IOO) is an integrated performance optimizer that dynamically manages I/O buffering to improve throughput for batch and online processing. StarTool IOO gathers information during I/O requests to VSAM and SAM (QSAM, BSAM, and EXCP) data sets and uses this information to access a knowledge base of I/O processing rules. It implements selected rules to analyze all data set information available from the catalog, control blocks, and operating dynamics. StarTool IOO then builds an I/O environment for each data set that maximizes processing efficiency, and it adjusts performance criteria and operating conditions based upon I/O requests.Release SummarySee “New Features in StarTool IOO 3.1 Patch 6” on page 3 for a list of the enhancements in StarTool IOO 3.1 Patch 6. See "Fixes in StarTool IOO 3.1 Patch 6" on page 3 for links to the defects that have been fixed inStarTool IOO 3.1 Patch 6.NOTE In StarTool IOO release 3.1.4.02, the default bufferspace for non-VSAM buffers was changed from 160KB (with reblocking) and 256KB (without reblocking) to 384KB (for both cases). This increase allows IOO to optimize the buffer count for non-VSAM files more fully.Note that even with this controlled increase in the bufferspace values, it is possible for an application that (1) uses a very large number of non-VSAM data sets, and (2) is close to exceeding the maximum possible region size, to in fact receive region abends.In those cases, you can use the BUFNO parameter in IOO's Dynamic Control Facility (DCF) rules to reduce the non-VSAM bufferspace for those jobs. Otherwise, contact Customer Support for additional guidance.Customer Support⏹Online Support — The Micro Focus Support website at https:///en-us/support/StarTool%20IOO%20(Input%2FOutput%20Optimizer) provides an easy way for customers to manage their support cases, download software patches, or search the Knowledge base for the latest technical information about our products at any time.⏹ A user ID and password are required to access some of the resources on the Micro Focus Supportwebsite. To obtain a user ID and password, sign up online or contact Customer Support by email or telephone.⏹Telephone Support — Telephone contact numbers for Customer Support are posted by region at thefollowing URL:https:///support-and-services/serena/No password is needed to access Customer Support contact information.⏹Email Support — Customers can send support requests by email to***************************.⏹Authorized Support Representative — Some support contracts specify that support calls will becentrally managed within the customer organization. This practice enables related issues to beaggregated across multiple customer sites or functional groups, and it ensures accountability for the satisfactory resolution of open issues. You should determine whether you have such a support contract before contacting Customer Support. If you do have such a contract, submit your support request to the designated support manager within your organization and arrange for that person to contact Customer Support.New Features in StarTool IOO 3.1 Patch 6There are no new features for this release.Fixes in StarTool IOO 3.1 Patch 6Access the following link for a list of defects and description of the fixes in StarTool 3.1 Patch 6:https:///s/article/KM000003615New Features and Fixes in Previous StarTool IOO ReleasesYou can access the following links to review the features and fixes in previous StarTool IOO releases.New Features in StarTool IOO 3.1.5.02https:///s/article/KM000003614Fixes in StarTool IOO 3.1.5.02/InfoCenter/index?page=content&cat=STRIOO_3.1.5.02_RESOLV ED&channel=DEFECTSNew Features in StarTool IOO 3.1.5.01/InfoCenter/index?page=content&id=S143105Fixes in StarTool IOO 3.1.5.01/InfoCenter/index?page=content&cat=STRIOO_3.1.5.01_RESOLV ED&channel=DEFECTSNew Features in StarTool IOO 3.1.5/InfoCenter/index?page=content&id=S143104Fixes in StarTool IOO 3.1.5/InfoCenter/index?page=content&cat=STRIOO_3.1.5_RESOL VED&channel=DEFECTSInstallation ConsiderationsYou can download the distribution files for the StarTool IOO 3.1 Patch 6 release from the StarTool IOO Support Site (https:///en-us/support/StarTool%20IOO%20(Input%2FOutput%20Optimizer).Before installing StarTool IOO 3.1 Patch 6⏹Make sure you have installed StarTool IOO 3.1.5 before you install this patch. The StarTool IOO 3.1 Patch 6 is not a full installation package. The distribution files in the StarTool IOO 3.1 Patch 6 release contain only the changes that have been made to product files since the StarTool IOO 3.1.5 release.Upgrading from StarTool IOO 3.1.5, 3.1.5.01, or 3.1.5.02Download the patch⏹Copy the ioo-3-1-patch-6.zip file from the Micro Focus Product Download site to your PC and extract the contents.Apply the patchThis maintenance package contains 5 files which are in “TSO transmit” binary format. You will need to transmit each of these files to the mainframe as follows.•STRIOO.V3R1P06.CLIST •STRIOO.V3R1P06.LOAD •STRIOO.V3R1P06.MAC •STRIOO.V3R1P06.PANELS •STRIOO.V3R1P06.SRC1Transmit each file to the mainframe using an appropriate data transmission method or software (e.g. an FTP Client product). Each target dataset must have the following attributes: DSORG=PS,RECFM=FB,LRECL=80,BLKSIZE=31202Receive each of the five transmitted files on the mainframe using the following command format:TSO RECEIVE INDSNAME('')Prepare to implement the patchNOTE You can install the 3.1 Patch 6 over the 3.1.5.01 and 3.1.5.02 patches. (This patch includes the fixes from patch 3.1.5.01 and patch 3.1.5.02).The steps you need to perform to prepare for implementation depend on which release you are upgrading from (3.15, 3.1.5.01, or 3.1.5.02).The following macro and source members were changed in IOO 3.1.5.01 and IOO 3.1.5.02.IOO 3.1.5.01 ChangesIOO macros #BYPASS and ULTIGBL were changed in IOO 3.1.5.01: library IOO315.MACThe source for ULTIGBK0-5 and ULTITBK0-5 were also changed in IOO 3.1.5.01: library IOO315.SRC IOO 3.1.5.02 ChangesIOO macros #BYPASS was changed in IOO 3.1.5.02: library IOO315.MAC.Thus ULTITBK0-5 have been recompiled to pick up the new #BYPASS.1If you are upgrading from 3.1.5 GA (with no patch levels applied) to 3.1 Patch 6:a Copy forward any custom modifications to the new versions of #BYPASS, ULTIGBL, ULTIGBK0-5 andULTITBK0-5.b Reassemble your global options - IOO315.JCL(IOOGASM)c Reassemble your site options - IOO315.JCL(IOOTASM)2If upgrading from 3.1.5.01 to 3.1 Patch 6:a Copy forward any custom modifications to the new versions of #BYPASS and ULTITBK0-5.b Reassemble your site options - IOO315.JCL(IOOTASM).3If upgrading from 3.1.5.02 to 3.1 Patch 6, no pre-implementations steps are required. Simply copy forward any modified versions of the components listed above from your IOO 3.1.5.02 libraries.Implement the patch1Stop the IOO started task.2Make a backup copy of the running libraries affected by the fix.•IOO315.CLIST•IOO315.LOAD•IOO315.MAC•IOO315.PANELS•IOO315.SRC3Copy the members and load modules from the temporary data sets into your running libraries.4Perform an IPL or refresh LLA. This is recommended before starting StarTool IOO 3.1.5.02, and required if upgrading from a release prior to StarTool IOO 3.1.5. Performing an IPL is recommended. If you do not want to perform an IPL for any reason, refresh LLA.5Restart the IOO started task.Software CompatibilityFor a complete list of software requirements and product compatibility, see the product compatibility matrix spreadsheet on the Software Licenses and Downloads (SLD) website:https:///nidp/idff/sso?id=5&sid=2&option=credential&sid=2. Storage RequirementsStarTool IOO allocates approximately 500K of 31-bit Extended Common Storage (ECSA) and 30K of 24-bit Common Storage (CSA) at startup. Within an application's address space, IOO allocates 24K for each open VSAM Access Control Block (ACB). Additional storage requirements vary dynamically based on the startup option chosen, the current application workload, and the optimization rules currently in force.OtherOther compatibility requirements of StarTool IOO include:Feature or Standard Compatible VersionsCharacter Set EBCDIC - Latin 13270 Emulation Code Page 037 U.S. EnglishNo known issues exist in StarTool IOO 3.1 Patch 6 .Documentation UpdatesStarTool IOO documentation is provided in Adobe ® Portable Document Format (PDF). You can download it from the following Micro Focus website:https:///documentation/startool-ioo/Adobe ® Reader ® is available for free download at /reader/. Version 9 or higher is recommended.Additions and corrections to documentation can be issued after the product release date. Updated StarTool IOO Readme files and user manuals are published on the Micro Focus documentation website cited above with the rest of the documentation for the product release. Updated Readme files and user manuals are flagged with an Updated date in the file name or description.Searching the DocumentationThere is no cross-book index for the StarTool IOO documentation suite. You can use the Advanced Search facility in Adobe Reader to search all StarTool IOO manuals in the same or subordinate folders for information that you want.Documentation Changes Regarding StarTool IOO MessagesStarTool IOO messages now appear in the JESMSGLG. All references to messages appearing in JESYSMSG should be changed to JESMSGLG in the following StarTool IOO user manuals:⏹Installation and Setup Guide ⏹Messages ⏹User’s GuideNOTE Change bars in the left margin of StarTool IOO documentation identify substantive changes from the last published version, unless otherwise noted.。
871A includes 2 free 1 m (40") Type K insulated FreeThermocouples Included!L-50Thermocouple Thermometerwith Dual InputsSpecificationsAccuracy: ±(0.25% of rdg + 1.8°F) for 1 year, 18 to 28°C (64 to 82°F) ambient; includes NIST conformity (no data points), cold junction compensation and repeatability errors; excludes thermocouple errorsRepeatability: ±0.2°C typical for 1 week at constant ambient temperatureTemperature Coefficient: 18 to 28°C (64 to 82°F); included in accuracy specification; 0 to 18°C (32 to 64°F) and 20 to 50°C (82 to 122°F); less than ±(0.025% of reading) + 0.1°C/°C Linearization: Multislope A/D with 11 piece-wise linear segments from -40 to 1370°C (-40 to 1999°F)Display: 31⁄2 digit LCD, 15 mm(0.6") height, polarity, decimal point, open sensor, overrange and open thermocouple indicationReading Rate: 2.5 per secondTemperature Settings 200°F:Range: -40.0 to 199.9°F Resolution: 0.1°FAccuracy: (±0.25% rdg + 1.8°F)2000°F:Range: -40 to 1999°F Resolution: 1°FAccuracy: (±0.25% rdg + 1.8°F)200°C:Range: -40.0 to 199.9°C Resolution: 0.1°CAccuracy: (±0.25% rdg + 1°C)1370°C:Range: -40 to 1370°C Resolution: 1°CAccuracy: (±0.25% rdg + 1°C)Battery Life: 100 hours typical, with 9V alkaline battery (included)Battery Indicator: Display reads “BAT” when less than 10% of life remains Analog Output: 1 mV/°C (5/9 mV/°F) on 200° ranges; 0.1 mV/°C (5/90°F) on other rangesAnalog Output Accuracy: ±3% ±1 mV on 200° ranges; ±3% ±0.1 mV on other ranges (±5% for 872A)Environmental Limits:Operating: 0 to 50°C (32 to 122°F) Storage: -35 to 60°C (-31 to 140°F)Max Common Mode Voltage: 500V Dimensions:178 H x 78 W x 42 mm D (7 x 3.1 x 1.6")Net Weight: 300 g (10.6 oz)Accessories Supplied: 9V battery, operator’s manual, thermocouple, TAS adaptorthermocouples, TAS adaptor.Ordering Examples: 871A, Type K dual input thermometer, and KTSS-HH, Type K meter probe.OCW-3, OMEGACARE SM extends standard 1-year warranty to a total of 4 years.OMEGACARE SM extended warranty program is available for models shown on this page. Ask your sales representativefor full details when placingan order. OMEGACARE SMcovers parts, labor and equivalent loaners.U C ertificate Stating NIST-Traceability (No Points) Included U Type K Thermocouple U Heavy-Duty Construction U 0.1° and 1° Resolution U °C/°F Switchable U 0.25% AccuracyU Linearized Analog Output 871A shown smallerthan actual size.No PointsKTSS-HH 6" Type K thermocouple probe (sold separately).。