G5.Control PC-Software for Operating and Service of the G5 Family G5.Control allows complete and easy control of the power supply unit or entire master-slave system and also offers a whole range of service functions. In addition to basic control, configuration and update functions, G5.Control has a powerful integrated 8-channel digital scope. The high-resolution real-time display of numerous internal system signals allows the engineer to optimize the overall system in a targeted manner. Different application specific settings of parameters for single devices or master-slave systems can be saved on the devices and either recalled by G5.Control, an API or CAN message or digital I/O signals. Firmware updates can be carried out quickly and easily for individual units as well as for master-slave systems with a single command. When handling support cases concerning the application of the power supplies, the built-in diagnostic functions help to quickly identify the problem. Key Features & Functionality ▪ G5.Control softwarre included in the scope of delivery of every G5 programmable DC power supply ▪ Upper and lower output value limiters for voltage, current and power with dynamic change of the control mode ▪ Upper and lower trip and warning limit values for voltage, current and power allows the user to programm a digital fast-acting fuse and to protect electrial installation and device under test (DUT) ▪ Programming of optional function generator TFE and AAP ▪ Digital 8-channel scope functionality for data analysis and application specific system control optimization ▪ Activation and saving of application specific configuration settings on the device ▪ Free configuration of all analog and digital I/O channels ▪ Graphical supported multi-device system configuration ▪ Firmware updates of a single unit as also of multi-device systems ▪ Option enabling allows remote activation of additional functionalities at a later stage ▪ Tabs can be arranged individually on the screen by the user Product Description G5.Control
CONTROLEDGE™
HC900
Process Control and Safety Made Easy
The ControlEdge HC900 is fully
validated to perform its safety tasks,
and is certified by TUV for use in a SIL-
2 environment. The system isideal for a
process/safety environment. Its non-interfering software means
that the ControlEdge HC900 system is
capable of hosting process control and
safety applications, providing control,
monitoring, password protection for configuration, alarm processing
and data acquisition for process
applications thus adding to reliable
data and information being stored and
protected.TUV ComplianceTYPICAL INDUSTRIES
• Chemicals (including specialty and
fine chemicals, plastics and rubber)
• Life sciences and Cosmetics
• Power (excluding nuclear)
• Cement and Glass
• Pulp and Paper
• Mining and Metals
• Water and Wastewater
• Food and Beverage
GEH-908P SUPERSEDES GEH-908N CONTROL AND INSTRUMENT SWITCHES @ TY pes SB-1, SB-9, and SB-IO INSTRUCTIONS CONTROL AND INSTRUMENT SWITCHES TYPES SB-1, SB-9, AND SB-10 INTRODUCTION The Type SB-1 switches (see cover illustration and Fig. 1) are multi-pole rotary switches with cam- operated contacts. They have their positioning devices or return springs located between the front support and first barrier while the Type SB-9 (see Fig. 2) has the positioning device or return spring located at the rear of the switch. The Type SB-9 also has better insulation to ground, more substantial bearings, and long life cams. The Type SB-10 switches (see Fig. 3) combine contacts operated by rotation of the shift, as in the SB-1 and 9 switches, with contacts operated by a lateral motion (push or pull) of the shaft. Only two lateral positions of the shaft are possible. Interlocks are usually provided so the push-pull contacts can be oper- ated only in specific rotary positions of the switch, and also the rotary contacts can be operated in only one lateral position of the shaft, either push or pull. NOTE: Instructions for Type SB-1 switches also apply to superseded Type SB-7 switches. APPLICATION The Type SB-1 , SB-9 and SB-10 switches are primarily intended for the control of electrically operated circuit breakers, small motors, magnetic switches and similar devices, and for the transfer of meters, in- struments and relays. The Type SB-1 switch is suitable for most applications, but where the switch is sub- ject to abnormally frequent operation (approximately 100 operations or more per hour, more durable cams are required, in which case the Type SB-9 switch should be ordered. RATINGS All switches are rated 600 volts, 20 amperes continuous, and 250 amperes for three seconds. The interrupting rating depends on several factors; namely, voltage, current, and inductance of the circuit. It is often necessary to connect several contacts in series to secure sufficient interrupting capacity. The interrupting ratings in the table below are based on the inductance of the average trip coil. INTERRUPTING RATINGS - AMPERES 1 These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred to the General Electric Company. To the extent required the products described herein meet applicable ANSI, IEEE and NEMA standards~ but no such assurance is given with respect to lzal codes and ordinances because they vary greatly. CIRCUIT VOLTS 24 DC 48 DC 125 DC 250 DC 600 DC 115 AC 220 AC 440 AC 550 AC 1 NON-INDUCTIVE CIRCUIT I I INDUCTIVE CIRCUIT NUMBER OF CONTACTS 4 in Series 30.0 25.0 9.5 6.5 1.25 40.0 20.0 15.0 1 6.0 5.0 2.7 0.75 0.25 40.0 25.0 12.0 6.0 2 in Series 30.0 25.0 11 .O 2.0 0.45 75.0 50.0 25.0 12.0 2 in Series 20.0 15.0 6.25 1.75 0.35 50.0 25.0 12.0 10.0 4 in Series 40.0 25.0 8.0 1.35 1 4.0 3.0 2.0 0.7 0.15 24.0 12.0 5.0 4.0
September 2015, Rev. 2, 1/20 (Simplified Chinese)
©2015-2020 Fluke Corporation. All rights reserved.
All product names are trademarks of their respective companies.1736/1738Power Logger
用户手册有限保证和责任限制
在正常使用和维护条件下,Fluke 公司保证每一个产品都没有材料缺陷和制造工艺问题。保证期为从产品发货之日起二(2)年。部件、产品修理和服务的保证期限
为 90 天。本项保证仅向授权零售商的原始买方或最终用户提供,并且不适用于保险丝和一次性电池或者任何被 Fluke 公司认定由于误用、改变、疏忽、意外非正常
操作和使用所造成的产品损坏。Fluke 公司保证软件能够在完全符合性能指标的条件下至少操作 90 天,而且软件是正确地记录在无缺陷的媒体上。Fluke 公司并不
保证软件没有错误或无操作中断。
Fluke 公司仅授权零售商为最终客户提供新产品或未使用过产品的保证。但并未授权他们代表 Fluke 公司提供范围更广或内容不同的保证。只有通过 Fluke 授权 的销
售商购买的产品,或者买方已经按适当的国际价格付款的产品,才能享受 Fluke 的保证支持。在一个国家购买的产品被送往另一个国家维修时,Fluke 公 司保留向买
方收取修理/更换零部件的进口费用的权利。
Fluke 公司的保证责任是有限的,Fluke 公司可以选择是否将依购买价退款、免费维修或更换在保证期内退回到 Fluke 公司委托服务中心的有缺陷产品。
要求保修服务时,请与就近的 Fluke 授权服务中心联系,获得退还授权信息;然后将产品连同问题描述寄至该服务中心,并预付邮资和保险费用(目的地离岸价
格)。Fluke 对运送途中发生的损坏不承担责任。在保修之后,产品将被寄回给买方并提前支付运输费(目的地交货)。如果 Fluke 认定产品故障是由于疏忽、误