61850-7-1h
- 格式:pdf
- 大小:2.88 MB
- 文档页数:92


Eaton 180701Eaton DE11 Variable speed starters, Rated operational voltage 400V AC, 3-phase, Ie 5 A, 2.2 kW, 3 HP, Radio interferencesuppression filter DE11-345D0FN-N20NN01General specificationsProduct Name Catalog NumberEaton DE11 Variable speed starter180701EAN Product Length/Depth4015081758661169 mmProduct Height Product Width230 mm90 mmProduct Weight Certifications1.6 kg IEC/EN 61800-3Specification for general requirements:IEC/EN 61800-2Safety requirements: IEC/EN 61800-5-1Catalog Notes Model CodeOverload cycle for 60 s every 600 s DE11-345D0FN-N20NN01Parameterization: Keypad Parameterization: Fieldbus Parameterization: drivesConnect Parameterization: drivesConnect mobile (App)Radio interference suppression filter C1 ≤ 5 m, Radio interference level, maximum motor cable lengthC3 ≤ 25 m, Radio interference level, maximum motor cable lengthC2 ≤ 10 m, Radio interference level, maximum motor cable lengthOP-Bus (RS485), built inModbus RTU, built inCANopen®, built inYesIn conjunction with DX-NET-SWD3 SmartWire DT moduleIP20NEMA Other1st and 2nd environments (according to EN 61800-3)FS2Variable speed starterFinger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)Other bus systemsEtherNet/IPMODBUSC1: for conducted emissions onlyC2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.15 g, Mechanical, According to IEC/EN 60068-2-27, 11 msBranch circuits, (UL/CSA)FeaturesFitted with:Cable lengthCommunication interfaceConnection to SmartWire-DTDegree of protectionElectromagnetic compatibilityFrame sizeProduct categoryProtectionProtocolRadio interference classShock resistanceSuitable forResistance: According to EN 61800-5-1Above 1000 m with 1 % derating per 100 mMax. 2000 m-10 °C60 °C-40 °C70 °C< 95 average relative humidity (RH), no condensation, nocorrosion7 A< 3.5 mA (AC-operated)< 10 mA (DC-operated)Maximum of one time every 30 seconds380 V480 VSpeed control with slip compensation U/f control0 Hz300 Hz 4.8 A5 A5 A4.8 A3 HP3 HP3.46 kVA4.16 kVAVibrationAltitudeAmbient operating temperature - minAmbient operating temperature - maxAmbient storage temperature - minAmbient storage temperature - maxClimatic proofingInput current ILN at 150% overload Leakage current at ground IPE - max Mains switch-on frequencyMains voltage - minMains voltage - maxOperating modeOutput frequency - minOutput frequency - maxOutput voltage (U2)Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload Assigned motor current IM at 230 V, 50 Hz, 150% overload Assigned motor current IM at 400 V, 50 Hz, 150% overload Assigned motor current IM at 440 - 480 V, 60 Hz, 150% overload Assigned motor power at 230/240 V, 60 Hz, 1-phaseAssigned motor power at 460/480 V, 60 Hz, 3-phaseApparent power at 400 VApparent power at 480 V400 V AC, 3-phase 480 V AC, 3-phase7.5 A10 V DC (Us, max. 0.2 mA)45 Hz66 Hz5 A at 150% overload (at an operating frequency of 16 kHz and an ambient air temperature of +50 °C)2.2 kW2.2 kW0.03 Hz (Frequency resolution, setpoint value)15 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring200 %, IH, max. starting current (High Overload), For 1.875 seconds every 600 seconds, Power section50/60 Hz16 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit480 V Max. 30 % MN, Standard - Main circuitAdjustable to 100 %, DC - Main circuit1 (parameterizable, 0 - 10 V DC, 0/4 - 20 mA)4 (parameterizable, 10 - 30 V DC)1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))65 W0 W0 W5 A0 WOperation (with 150 % overload)Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Overload current IL at 150% overloadRated control supply voltageRated frequency - minRated frequency - maxRated operational current (Ie)Rated operational power at 220/230 V, 50 Hz, 1-phase Rated operational power at 380/400 V, 50 Hz, 3-phase ResolutionShort-circuit protection ratingStarting current - maxSupply frequencySwitching frequencyVoltage rating - max Braking torqueNumber of inputs (analog)Number of inputs (digital)Number of outputs (analog)Number of relay outputsEquipment heat dissipation, current-dependent PvidHeat dissipation capacity PdissHeat dissipation per pole, current-dependent PvidRated operational current for specified heat dissipation (In) Static heat dissipation, non-current-dependent PvsHeat dissipation details10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Starting, Stopping and OperationElectromagnetic compatibility (EMC)Access to Parameter Level 2 Parameter Lock Load Default Quick-Start-Guide DE11 (english)I/O ConfigurationConnecting drives to generator suppliesMotor data Motor Protection V/f curves Slip CompensationSet point settingConformal CoatingFire modeQuick-Start-Guide DE1 (english)Start, Stopp und BetriebHow does the internal motor protection work?The OP System Bus - Parameterizing - ControlDX-COM-STICK3_ConnectionUpdate DX-COM-STICK3HVAC, water/wastewater and industrial mediums - brochure Number 1 in efficiency The easiest way of variable motor speed PowerXL DE1 Variable Speed StarterDA-SW-drivesConnect - installation helpDA-SW-Codesys 3 SWD for DC1 and DE1DA-SW-DE11 CANopen ConfigFile 203DA-SW-DE11 CANopen ConfigFile 210DA-SW-Driver DX-CBL-PC-3M0DA-SW-Codesys 2 SWD for DC1 and DE1DA-SW-drivesConnect - InstallationshilfeDA-SW-USB Driver PC Cable DX-CBL-PC-1M5DA-SW-DE11 CANopen CODESYS2 LibraryDA-SW-DE1 ModbusRTU V1_00 LibraryDA-SW-drivesConnectDA-SW-DE11 CANopen CODESYSV3 LibraryDA-SW-USB Driver DX-COM-STICK3-KITDA-SW-drivesConnect USB Driver DX-COM-PCKITProduct Range Catalog Drives Engineering10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components 10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material 10.10 Temperature rise10.11 Short-circuit rating Application notes Brochures CataloguesEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All rights reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaIs the panel builder's responsibility. The specifications for the switchgear must be observed.Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.Drives - Product range catalogDA-DC-00004551.pdfDA-DC-00004556.pdfeaton-frequency-inverter-dimensions-010.eps eaton-frequency-inverter-3d-drawing-018.epsDA-CE-ETN.DE11-345D0FN-N20NN01IL040005ZUPowerXL DE1 variable speed starterMN040011_ENMN040003_ENMN040019_ENMN040018_ENDA-CD-de1_fs2_ip20DA-CS-de1_fs2_ip2010.12 Electromagnetic compatibility 10.13 Mechanical function Certification reports DrawingseCAD model Installation instructions Installation videos Manuals and user guidesmCAD model。