UIS-Cell3000超融合一体机部署手册
- 格式:docx
- 大小:1.34 MB
- 文档页数:38
H3C UIS-Cell 3000 SeriesHyper-Converged InfrastructureCompliance and Safety Manual New H3C Technologies Co., Ltd.Document version:5W101-20170315Copyright © 2016-2017, New H3C Technologies Co., Ltd. and its licensorsAll rights reservedNo part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co., Ltd.TrademarksH3C, , H3CS, H3CIE, H3CNE, Aolynk, , H 3Care, , IRF, NetPilot, Netflow, SecEngine, SecPath, SecCenter, SecBlade, Comware, ITCMM and HUASAN are trademarks of New H3C Technologies Co., Ltd.All other trademarks that may be mentioned in this manual are the property of their respective owners NoticeThe information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.Technical supportservice@Obtaining documentationYou can access the most up-to-date H3C product documentation on the World Wide Web at this URL: .The following are the columns from which you can obtain different categories of product documentation:[Products & Solutions]: Provides information about products and technologies, as well as solutions.[Technical Support & Document > Technical Documents]: Provides several categories of productdocumentation, such as installation, operation, and maintenance.[Technical Support & Document > Product Support > Software]: Provides the documentation released with the software version.Documentation feedbackYou can e-mail your comments about product documentation to info@.We appreciate your comments.Environmental protectionThis product has been designed to comply with the environmental protection requirements. The storage, use, and disposal of this product must meet the applicable national laws and regulations.ContentsSafety Information/Sicherheits informationen/安全信息 (1)Overview/Überblick/概述 (1)Warning Symbol Conventions/ Erläuterung der Symbole/应用惯例 (2)Important Safety Information/Wichtige Sicherheitshinweise/重要安全信息 (3)Electricity Safety/Elektrische Sicherheit/用电安全 (6)Hazardous Voltage/Gefährliche Spannungen /危险电压 (6)Regulatory Compliance Information (7)Regulatory compliance standards (7)European Directives compliance (7)USA regulatory compliance (7)FCC Part 15 (7)Canada regulatory compliance (8)ICES-003 (8)Japan regulatory compliance (8)VCCI (8)EN55022, CISPR22 compliance (8)EN55032, CISPR32 compliance (8)中国Class A声明 (8)Environmental notices (9)Waste Electrical and Electronic Equipment (WEEE) statements (9)English recycling notice (9)Bulgarian recycling notice (9)Czech recycling notice (10)Danish recycling notice (10)Dutch recycling notice (10)Estonian recycling notice (11)Finnish recycling notice (11)French recycling notice (11)German recycling notice (12)Greek recycling notice (12)Hungarian recycling notice (12)Italian recycling notice (13)Latvian recycling notice (13)Lithuanian recycling notice (13)Polish recycling notice (14)Portuguese recycling notice (14)Romanian recycling notice (14)Slovak recycling notice (15)Spanish recycling notice (15)Swedish recycling notice (15)RoHS material content declarations (16)Turkey RoHS material content declaration (16)Ukraine RoHS material content declaration (16)India RoHS material content declaration (16)Perchlorate material — Special handling may apply (16)List of TablesTable 1 Safety symbol and description/Sicherheitssymbole und Beschreibung/安全标识和描述 (2)Table 2 Regulatory compliance standards (7)Safety Information/Sicherheits informationen/安全信息Overview/Überblick/概述WarningInstallation and removal of the unit and its accessories must be carried out by qualified personnel.You must read all of the Safety Instructions supplied with your equipment before installation andoperation.WarnungInstallation und Ausbau der Anlage und ihrer Zubehörteile müssen von qualifiziertem Personalrealisiert werden. Sie müssen vor der Installation oder Bedienung allen beiliegendenSicherheitshinweise lesen.警告负责安装和日常维护本设备及其配件的人员必须具备安全操作基本技能。
H3C超融合整体解决方案介绍安全应用网络计算存储安全应用网络计算资源池存储资源池存储资源池网络资源池计算资源池安全资源池应用u 计算、存储虚拟化;u 资源利用率提升;u 管理与IT交付模式没有改变;u 网络、安全需要人工配置;u 集中管理u 孤岛式建设;u IT资源无法灵活调度;u IT资源利用率低;u 计算、存储、网络、安全、应用等IT资源作为服务交付u 自动化,所有操作由云平台自动化操作u IT资源能够由云平台弹性伸缩u 可运营的云计算中心云操作系统数据中心发展趋势传统数据中心虚拟化数据中心云化数据中心1、建设维护成本高、资源利用率低2、管理复杂,维护工作量大3、业务部署慢,不灵活数据中心发展的两大趋势Google 数据中心•去小机•分布式存储•NFV技术技术驱动业务驱动•快速部署•灵活变更•易扩展•提升资源利用率超融合软件定义基础架构数据中心向X86架构迁移H3C UIS超融合整体解决方案UIS 3000UIS 8000UIS 4000计算(CAS)UIS OS超融合管理平台(深度融合全虚拟化平台))存储(ONEStor)网络(SDN/NFV)安全(vFW/vLB)云桌面(VDI)亚信安全(DS)爱数备份数据库一体机UIS基础架构层应用层云层超融合带来的价值全快省全——存储、计算、网络、安全四维一体四维一体资源全虚拟化单一X86平台高密设计计算存储ONEStor网络vSwitch/vRouter安全vFW/vLBUIS-Cell 3000CASUIS-Cell 4000Ø数据中心X86化,便于运维及大规模管理ØUIS manager实现业务自动化部署及管理Ø超融合横向扩展,可适应未来IT业务的扩容需求ØIT资源全虚拟化,使业务部署更加灵活、快速、易扩展UIS8000Web服务器文件服务器邮件服务器认证服务器OA服务器ERP服务器CRM服务器DNS服务器DB服务器u 提高服务器资源利用率u 降低硬件投资成本u 节省机房使用空间u 节能降耗u 业务快速统一部署u 提高系统可用性10%10%10%10%20%10%35%10%……Hypervisor(VMM:Virtual Machine Monitor)虚拟机操作系统业务系统硬件(CPU、内存、硬盘、网卡、USB、串口、…)虚拟机操作系统业务系统虚拟机操作系统业务系统UIS软件定义计算——CAS187K •VEPA解决方案•Overlay解决方案(VxLAN)•DRX解决方案(LB,vLB)•PoC云点解决方案•OVS功能增强(QoS,双向ACL…)兼容性28K•兼容VMware vSphere•兼容自研/第三方服务器•兼容第三方存储设备•兼容第三方软件(OS,App)•兼容RAID卡、网卡、HBA卡标准与开放90K•OpenStack H/J/K版本Plugin•北向REST API接口•IEEE 802.1Qbg、IEEE 802.1BR•OVF•SR-IOV总计1052K行HA59K•业界最大规模(128台)•物理主机和虚拟机HA•操作系统及应用HA•跨DC在线迁移安全性63K•管理接入安全•虚拟磁盘安全销毁•备份和快照•虚拟化防病毒内核深度优化38K •虚拟时钟性能优化•虚拟CPU调度优化•虚拟磁盘/内存优化•虚拟网络内核加速可管理性587K•CVM•CIC•SSV 源于KVM,优于KVM云网融合7年研发创新5年成熟商用400+项国家发明专利No.1SPECvirt性能业界最佳3000+累计服务客户2688单项目CPU授权中国最好的虚拟化平台企业级特性丰富克隆、数据精简、快照、纠删码、数据分层、读写加速等数据高可靠11个9高可靠性统一存储同时提供块、对象、NAS对象服务 块存储服务NAS服务业务处理数据库大数据备份门户邮件云计算虚拟桌面云存储/云网盘文件存储ONEStorOpenStack VMVMVMVMUIS超融合存储组件——ONEStorONEStor高可靠-分布式存储卷卷1卷2卷3……Server 1Server 2Server 3Server 4 Server 5Server 6数据随机打散分布在不同的物理节点上,每个节点同时提供存储服务,全分布式架构ONEStor高可靠-多副本技术卷1卷2卷3……Server 1Server 2Server 3Server 4 Server 5Server 6DEFFEDA B C G H IGHIABC 多副本存储技术类似RAID,数据存多份,保障节点级宕机时的数据可靠性ONEStor高可靠-数据自动重构机制卷1卷2卷3……Server 1Server 2Server 3Server 4 Server 5Server 6DEFD E FE DA B C G H IA B C G H I H GBC AI F 当有节点发生故障,数据可自动进行重构,保障存储集群的数据完整性CA BBA 数据块C BC A BC A节点1节点2节点3节点5节点4l 多副本存储空间利用率则为1/N, N=K+M纠删码的空间利用率是K/N,如上图同样是5个节点,做3+2纠删码,空间利用率是3/5l 两种存储方式的使用场景不同,两者只能选其一;多副本方式主要用于生产系统,性能和可靠性要求高;纠删码方式主要用于冷数据存储,例如备份,归档等,对空间利用率高,性能无要求的场景。
超融合一体机家族丰富的硬件款型硬件服务器全自研,可满足用户特定化、个性化需求硬件款型齐全,用户可按需搭配,供应链按需集成安装。
实验室预优化、预验证,软硬件一体化交付。
随需选配超融合一体机硬件款型解析UIS 3000G3系列UIS 9000系列UIS 6000G3系列UIS 5000G3系列UIS 4500G3系列UIS 5300系列Copyright ©2019 新华三技术有限公司版权所有,保留一切权利本文中的内容为通用性技术信息,某些信息可能不适用于您所购买的产品新华三资料开发部出品这么多种型号,我们很为难啊到底哪个型号才适合我们呢?这么说来,还真是各种需求都难不倒你们啊。
客户B针对客户B 的这种情况推荐使用H3C UIS 4500 G3系列超融合一体机它的优势在于大容量存储空间,支持机箱入侵报警4U2路提供最大40LFF+4SFF 存储空间如果塞满3.5寸的硬盘你将拥有单台0.5Pb 的存储容量它可以解决云备份需求融媒云需求大容量存储需求HDM 防火墙功能,可基于MAC 地址,IP 定义访问规则我们公司数据量很大,又需要备份,而且对数据的安全性要求也较高,该怎么办好呢?客户C针对客户C 的这种情况我们推荐H3C UIS 5000 G3系列超融合一体机它的特点是可以在2U 机箱中集成4颗CPU 基于最新Intel Purly 平台CPU 26块SFF 硬盘,含16个NVMe SSD满足了高密度计算需求低成本高性能计算需求我们公司想要选购计算性能强的云计算服务器,但是我们的机柜位置紧张,你们有什么合适的产品吗?客户D针对客户D 的这种情况推荐使用H3C UIS 5300 G3系列超融合一体机因为高密GPU8*双宽GPU 或者20*单宽GPU 支持OCP 3.0网卡,支持AEP所以它适用于视频编解码二维、三维图形处理科学研究我们是一家设计院,现在三维设计软件的应用越来越广泛,在做模型渲染的时候很痛苦,你们有什么好的建议吗?客户E针对客户E 的这种情况我们推荐H3C UIS-Cell 6000 G3系列超融合一体机它的优点是基于最新Intel Skylake 架构CPU 2路4路架构灵活扩展最大48个2.5寸硬盘,或最大16个NVMe 硬盘所以它解决了关键业务高性能高可靠性的需求高性能计算的需求我们公司有些关键业务,我们需要更可靠的设备,并且对于计算性能和存储容量都有较高的要求,该怎么才能让老板满意啊?客户F针对客户F 的这种情况推荐使用H3C UIS-Cell 9000 G3系列超融合一体机因为它具有最大16片两路刀片,或8片全宽存储节点,或8片4路刀片6+2个网络交换模块,背板带宽最高达42T 独有的HDD BAY 设计,支持最高288块硬盘它可以做到多框级联,统一管理云网安融合独有的OM100管理模块:硬件统一管理,集成2*万兆+2*千兆端口,可作超融合管理网独立的UISM 管理模块数据中心虚拟化高扩展性一框即云我们公司的规模比较大,以上的需求我们都有,但是为了节省后期运维的成本,我们不太想上很多的设备,这可怎么办呢?客户A 针对客户A 这种情况我们推荐H3C UIS-Cell 3000 G3系列超融合一体机因为灵活多变,可以按需选配最大支持25SFF+8SFF(内置)+3LFF+4SFF 共40块硬盘所以它适合中小型数据中心分支机构密集存储服务器虚拟化我们公司规模不大,预算有限,近期想要给公司总部和分支机构选择支持云计算业务的服务器,该选择哪一款呢?性价比极高,可在预算有限的情况下,提供高性能的服务管理节点与业务节点分离大家不要急,提出你们的需求,我们来做一个详细的分析。
H3C UIS超融合基础架构解决方案建议书2018年12月新华三集团1、项目背景1.1传统架构面临的问题自上世纪90年代中后期开始,以大型机、小型机、大型数据库、集中式存储与业务高可用软件组成的IT架构适应了当时的数据大集中趋势,传统IT设备制造商在这一阶段得到了迅猛的发展,集中式的部署模式带来了对硬件性能、高可靠性及扩展性的需求增加。
2003年左右,服务器虚拟化技术开始普及,以VMware为代表的虚拟化软件厂商引领数据中心由物理硬件数据中心向虚拟化数据中心转变。
服务器虚拟化技术有效控制了数据中心内服务器数量规模的膨胀,提高了服务器的利用效率,并且,利用虚拟机迁移等技术大大降低了数据中心对服务器RAS 特征的依赖。
服务器虚拟化技术的大规模应用使得业务系统的部署呈现由Unix小型机平台迁移到x86 + 虚拟化 + 集中存储架构的趋势,x86刀片服务器 + 虚拟化 + 集中式存储阵列成为这一时期数据中心的主宰。
主流传统IT架构如下图:其要特点是:(1) X86服务器虚拟化已经得到普遍应用和认可。
小机用户集中在部分金融、医疗、和制造业等客户,而且因为成本高昂、架构封闭、不易运维等痛点,也正在逐步切换至X86服务器平台。
同时客户普遍使用虚拟化技术来提高可靠性和可用性,提升了服务器的资源利用率。
(2)使用集中式外部存储。
服务器本地没有存储能力,通过FC交换机连接至集中式存储,集中式存储的特点是通过双控机头或者多控机头连接磁盘柜,所有IO路径通过机头来控制。
(3)以方案集成的形式交付。
IT架构通常涉及众多厂商和品牌,设备种类多。
通常由集成商做系统集成来交付完整解决方案,后续运维无法实现一个管理软件实现全部配置、管理、监控功能。
随着企业业务规模的不断扩张,尤其是云计算大潮来临,IT平台的规模和复杂程度出现大幅度的提升,业务对IT基础架构的灵活性、可扩展性以及快速上线的能力提出了更高的要求,传统IT数据中心架构的弊端也逐渐显现,具体表现为:(1)架构复杂,管理困难,策略分散存储、服务器、网络安全设备三层堆栈部署存在明显的复杂性,需要对多层软硬件结构进行组装和调试,才能使其正常工作。
SX-3000独立媒体模块和便携型/企业级存储系统用户手册SMS版本 9.02015年4月20日目录目录1. 前言 (9)1.1. 关于本手册 (10)1.2.安全说明 (11)1.2.1. 一般安全说明 (11)1.2.2.电气安全 (11)2. SMS (12)2.1. 关于SMS 界面 (12)2.2.访问 SMS 界面 (12)2.3. 了解SMS 界面 (13)2.3.1.主菜单 (13)2.3.2. 放映表菜单 (15)2.3.3.排程菜单 (18)2.3.4.配置菜单 (19)2.3.4.1.一般选项 (19)2.3.4.2.字幕功能 (22)2.3.4.3.遥控支援 (23)2.3.4.4. 音频选项 (24)2.3.4.5. 隐藏式字幕选项 (25)2.3.4.6. 流媒体选项 (26)2.3.4.7IMB 网络选项卡 (27)2.3.4.8 IMB 存储选项卡 (29)2.3.5.SNMP配置 (30)2.3.5.1.简介 (30)2.3.5.2.访问 SNMP配置界面 (30)2.3.5.3.了解 SNMP配置界面 (32)2.3.5.3.1.一般选项 (32)2.3.5.3.2.存储 (33)2.3.5.3.3.视频卡 (34)-2-SX-3000独立媒体模块和便携型/企业级存储系统2015年4月20日目录SX-3000独立媒体模块和便携型/企业级存储系统2015年4月20日-3 -2.3.5.3.4. PCI ....................................................................................................................................................... 35 2.3.5.3.5. 传感器 ................................................................................................................................................ 36 2.3.5.3.6. 以太网 ................................................................................................................................................ 37 2.3.5.3.7. 重启/存储/取消 ................................................................................................................................. 38 2.3.6. 自动化 ...................................................................................................................................................... 39 2.4. 节目播放列表 ................................................................................................................................ 47 2.4.1. 创建节目播放列表 .................................................................................................................................. 47 2.4.1.1. 访问播放列表菜单 ............................................................................................................................... 47 2.4.1.2. 创建播放列表 ....................................................................................................................................... 48 2.4.1.3. 编辑线索 ............................................................................................................................................... 49 2.4.1.4. 保存播放列表 ..................................................................................................................................... 54 2.5. 放映时间表 ................................................................................................................................... 55 2.5.1. 编排放映时间表 ...................................................................................................................................... 55 2.6.同步节目........................................................................................................................................ 61 2.6.1. 同步剪辑以进行 3D 放映 (MPEG2)......................................................................................................... 61 2.7.服务器配置 .................................................................................................................................... 63 2.7.1.CineCanvas™ 和 CineLink™ 配置 ............................................................................................................... 63 2.7.2.杜比 3D 设置 ............................................................................................................................................. 67 2.8.第二代 DLPCINEMA ®放映机设置 .................................................................................................. 69 2.8.1.自动化设置 ............................................................................................................................................... 69 2.8.2.字幕渲染 ................................................................................................................................................... 71 2.8.2.1. 字幕渲染设置 ..................................................................................................................................... 71 2.8.2.2. 字幕语言选择 ..................................................................................................................................... 71 2.8.3.第二代放映机支持CineCanvas TM ............................................................................................................ 75 2.9.关机/重启应用程序......................................................................................................................... 76 2.9.1.关机或重启 .. (76)3.控制面板 (77)3.1.关于控制面板................................................................................................................................. 77 3.2.控制面板菜单 ................................................................................................................................. 78 3.3.自动化执行菜单 .. (79)目录3.4.重启控制面板 (81)3.5.关闭系统 (82)4.内容管理 (83)4.1. 关于内容管理 (83)4.1.1.简介 (83)4.1.2.访问内容管理 (83)4.2.内容管理 (84)4.2.1.载入内容 (84)4.2.2.从USB 磁盘载入内容 (86)4.2.3.载入 KDMs(密钥) (88)4.2.4.监控载入进度 (89)4.2.5.取消载入 (90)4.2.6.删除内容 (91)4.2.7.检查内容完整性 (92)4.3密钥管理 (97)4.3.1.管理密钥( KDM) (97)4.4.节目源管理 (98)4.4.1.添加节目源 (98)4.4.2.删除节目源 (101)4.4.3.编辑节目源 (102)5.管理面板 (104)5.1.简介 (104)5.2.用户界面 (UI) (105)5.2.1.简介 (105)5.2.2.访问管理面板 (105)5.2.2.1.通过控制面板访问 (105)5.2.2.2. 进入Admin Panel 按钮 (106)5.2.2.3.主菜单 (107)5.3.配置和维护 (109)5.3.1.存储系统管理 (109)-4-SX-3000独立媒体模块和便携型/企业级存储系统2015年4月20日目录SX-3000独立媒体模块和便携型/企业级存储系统2015年4月20日-5 -5.3.1.1. 创建新的 RAID 阵列.......................................................................................................................... 109 5.3.1.2. 监控 RAID 状态 ................................................................................................................................... 113 5.3.1.3. 硬盘信息 ............................................................................................................................................. 114 5.3.1.4. 磁盘使用情况 ..................................................................................................................................... 116 5.3.1.5. 存储性能 ............................................................................................................................................. 117 5.3.1.6. 提高重建速度 ..................................................................................................................................... 118 5.3.2.诊断 /维护 ............................................................................................................................................... 119 5.3.2.1. 访问诊断/维护 .................................................................................................................................... 119 5.3.2.2. 提取日志和配置 ................................................................................................................................. 120 5.3.2.3. 备份配置 ........................................................................................................................................... 121 5.3.2.4. 恢复配置 ............................................................................................................................................. 122 5.3.2.5. 设置时区 ............................................................................................................................................. 124 5.3.2.6. 软件升级 ........................................................................................................................................... 125 5.3.3.系统信息 ................................................................................................................................................. 127 5.3.3.1. 访问系统信息 ................................................................................................................................... 127 5.3.3.2.软件/操作系统版本 ............................................................................................................................ 128 5.3.3.3.硬件信息 .............................................................................................................................................. 129 5.3.3.4.补丁信息 .............................................................................................................................................. 130 5.3.4.触控屏 ..................................................................................................................................................... 131 5.3.4.1. 访问触控屏 ....................................................................................................................................... 131 5.3.4.2. 选择触控屏类型 ................................................................................................................................. 132 5.3.4.3. 校准触摸屏 ......................................................................................................................................... 134 5.4.用户管理...................................................................................................................................... 135 5.4.1.访问用户管理 ......................................................................................................................................... 135 5.4.2.添加/编辑用户........................................................................................................................................ 135 5.4.3 删除用户 ................................................................................................................................................. 137 5.4.4.更改当前用户密码 ................................................................................................................................. 139 5.5. DCI 功能 ..................................................................................................................................... 140 5.5.1. 访问DCI 功能 ......................................................................................................................................... 140 5.5.2. 微调时钟校准 . (141)目录5.5.3. 获取 SM(安全管理)日志 (142)5.6.退出/关机 (143)6. IMB操作注意事项 (145)6.1. 开机顺序 (145)6.2. 关机顺序 (145)-6-SX-3000独立媒体模块和便携型/企业级存储系统2015年4月20日感谢您购买环球数码创意科技有限公司的SX-3000 独立媒体模块和便携型 /企业级存储系统。
H3C UIS超融合基础架构解决方案建议书2018年12月新华三集团1、项目背景1.1传统架构面临的问题自上世纪90年代中后期开始,以大型机、小型机、大型数据库、集中式存储与业务高可用软件组成的IT架构适应了当时的数据大集中趋势,传统IT设备制造商在这一阶段得到了迅猛的发展,集中式的部署模式带来了对硬件性能、高可靠性及扩展性的需求增加。
2003年左右,服务器虚拟化技术开始普及,以VMware为代表的虚拟化软件厂商引领数据中心由物理硬件数据中心向虚拟化数据中心转变。
服务器虚拟化技术有效控制了数据中心内服务器数量规模的膨胀,提高了服务器的利用效率,并且,利用虚拟机迁移等技术大大降低了数据中心对服务器RAS 特征的依赖。
服务器虚拟化技术的大规模应用使得业务系统的部署呈现由Unix小型机平台迁移到x86 + 虚拟化 + 集中存储架构的趋势,x86刀片服务器 + 虚拟化 + 集中式存储阵列成为这一时期数据中心的主宰。
主流传统IT架构如下图:其要特点是:(1) X86服务器虚拟化已经得到普遍应用和认可。
小机用户集中在部分金融、医疗、和制造业等客户,而且因为成本高昂、架构封闭、不易运维等痛点,也正在逐步切换至X86服务器平台。
同时客户普遍使用虚拟化技术来提高可靠性和可用性,提升了服务器的资源利用率。
(2)使用集中式外部存储。
服务器本地没有存储能力,通过FC交换机连接至集中式存储,集中式存储的特点是通过双控机头或者多控机头连接磁盘柜,所有IO路径通过机头来控制。
(3)以方案集成的形式交付。
IT架构通常涉及众多厂商和品牌,设备种类多。
通常由集成商做系统集成来交付完整解决方案,后续运维无法实现一个管理软件实现全部配置、管理、监控功能。
随着企业业务规模的不断扩张,尤其是云计算大潮来临,IT平台的规模和复杂程度出现大幅度的提升,业务对IT基础架构的灵活性、可扩展性以及快速上线的能力提出了更高的要求,传统IT数据中心架构的弊端也逐渐显现,具体表现为:(1)架构复杂,管理困难,策略分散存储、服务器、网络安全设备三层堆栈部署存在明显的复杂性,需要对多层软硬件结构进行组装和调试,才能使其正常工作。
超融合数据中心管理操作手册目录Contents1.登录虚拟化平台 (3)1.1.使用vSphere Client登录 (3)1.1.1.多种视图查看虚拟化环境 (5)1.2.使用vSphere Web Client登录 (8)2.部署虚拟机 (9)2.1.新建虚拟机 (9)2.1.1.挂载系统镜像 (27)2.1.2.安装VMware Tools (32)2.2.从模板部署虚拟机 (37)3.管理虚拟机 (55)3.1.编辑虚拟机设置 (55)3.1.1.虚拟机连接USB设备 (57)3.2.使用虚拟机快照 (70)3.3.迁移虚拟机 (72)3.3.1.在线迁移虚拟机到其他主机 (73)3.3.2.在线迁移虚拟机到其他存储位置 (77)3.4.克隆虚拟机 (81)3.5.删除虚拟机 (82)4.管理虚拟机操作系统 (83)4.1.Windows Server (83)4.1.1.关闭系统防火墙 (83)4.1.2.禁用密码安全策略 (85)4.1.3.禁用IPv6 (86)1. 登录虚拟化平台可使用安装vSphere Client方式和vSphere Web Client(Web浏览器方式)登录虚拟化平台进行管理操作;其中vSphere Client可登录中央管理器vCenter Server或单台ESXi主机,vSphere Web Client只能登录vCenter Server。
1.1. 使用vSphere Client登录a)安装VMware vSphere 5.5后点击如下图标;b)输入vCenter Server地址和用户名密码后点击登录,或输入单台ESXi主机地址和用户名密码后连接;c)忽略安全警告,进入管理界面;1.1.1. 多种视图查看虚拟化环境vSphere Client提供多种视图查看虚拟化环境,包括主机和群集、虚拟机和模板、数据存储和数据存储集群、网络。
可点击地址栏进入主页界面进行切换;主机和群集视图下,左栏可显示ESXi主机、资源池和虚拟机,点击相应对象可在右栏多个标签下查看其详细信息;如点击CLUSTER(群集),摘要标签页下显示vSphere HA、vSphere DRS概要信息;点击地址栏切换到其他视图;虚拟机和模板视图;数据存储和数据存储集群视图;网络视图;1.2. 使用vSphere Web Client登录打开网页浏览器(要求较新的IE版本或Chrome、Firefox,并安装有Adobe Flash插件),输入vCenter Server地址https://192.169.110.50:9443/vsphere-client下载安装客户端基础插件后可在浏览器内打开虚拟机控制台登录完成后进入欢迎界面;点击左上角红色方框内图标,进入主页或vCenter Server界面进行查看;2. 部署虚拟机可通过新建虚拟机、从模板部署虚拟机等方式进行虚拟机的部署。
UIS配置指导选择机箱(必配)9801A0LM VC-UIS8000-Z数据通信-H3C UIS8000-4*FAN,1*POWER,1*OA,单相电源输入,统一基础架构系统-国内版说明:已标配1个电源、4个风扇、1个OA管理模块增配电源模块(选配,总共6个电源槽位)0202A0CE PWR-2400W-P2400W热插拔高级电源模块注意:单片B390满配功耗小于350W,单片B590满配功耗小于550W,单台刀片存储功耗130W,单台网络模块功耗小于120W,刀箱风扇电源等满配功耗小于710W,通过简单计算即可得出需要配置的电源数量。
一般情况下,UIS满配的情况下,4个电源模块可以提供N+1的冗余。
精确功耗可以使用HP Power Advisor计算0202A0CG OA-KVM-C8000BLc8000刀片机箱带KVM 的管理模块增配冗余OA 模块(选配,总共2个OA 槽位)0202A0D3PDU-32A 32A PDU 供电模块0404339616A 国标线外部电源线-国标交流220V16A-3m-3*1.5mm^2-黑-(PI 弯公)-(227IEC53-1.5^2(3C))-(C19直母)选择电源线(选配其中之一)说明:如果客户使用PDU 供电模式,且用户没有C19/C20标准的PDU 供电模块,则需要配置PDU-32A 供电模块,配合电源出厂自带的PDU 电源线工作。
如果客户不使用PDU 供电模式,则需要每个电源配置一条16A 国标线即可。
选择刀箱风扇(选配,总共10个风扇槽位)0202A0CF FAN-C8000BLc8000刀片机箱风扇注意:刀箱从左至右总共8个全高槽位,刀箱风扇配置依据刀箱槽位使用情况而定。
如果使用了1个槽位,至少配置4个风扇;如果使用了2~4个槽位,至少配置6个风扇;如果使用了4个以上的槽位,至少配置8个风扇;刀箱满配风扇为10个如果刀箱中配置刀片存储,则必须配置10个风扇增配光驱(选配)0202A0CR DVD-RW-Mobile-USB移动USB接口可读写光驱选择刀片服务器,支持16片B390或8片B590,可混插(必配)9801A0HS VC-FSR-B390-Z-L1H3C FlexServer B390,2*E5-2620,2*8GB,2*10GE Flex10 FLB网卡,刀片服务器9801A0HT VC-FSR-B390-Z-L2H3C FlexServer B390,2*E5-2620,2*8GB,2*10GE FlexFabric FLB网卡,刀片服务器9801A0HU VC-FSR-B390-Z-H1H3C FlexServer B390,2*E5-2650,2*8GB,2*10GE Flex10 FLB网卡,刀片服务器9801A0HV VC-FSR-B390-Z-H2H3C FlexServer B390,2*E5-2650,2*8GB,2*10GE FlexFabric FLB网卡,刀片服务器9801A0HW VC-FSR-B590-Z-L1H3C FlexServer B590,4*E5-4607,2*8GB,2*10GE Flex10 FLB网卡,刀片服务器9801A0HX VC-FSR-B590-Z-L2H3C FlexServer B590,4*E5-4607,2*8GB,2*10GE FlexFabric FLB网卡,刀片服务器9801A0HY VC-FSR-B590-Z-H1H3C FlexServer B590,4*E5-4620,2*8GB,2*10GE Flex10 FLB网卡,刀片服务器9801A0J0VC-FSR-B590-Z-H2H3C FlexServer B590,4*E5-4620,2*8GB,2*10GE FlexFabric FLB网卡,刀片服务器说明:Flex-10网卡和FlexFabric网卡的唯一区别在于FlexFabric比Flex-10网卡多了FCOE功能。
CHANGHONG CHI3000超融合系统 技术手册本技术手册从概念和体系结构方面介绍采用VMware vSAN和Intel Inside的CHANGHONG CHI超融合系统。
本技术手册首先介绍超融合基础架构如何推动数字转型,然后重点介绍作为业界卓越的超融合技术解决方案的CHANGHONG CHI系统。
2022年1月四川长虹佳华信息产品有限责任公司1目 录前言 (4)IT 面临的新挑战:引领数字转型 (4)数字转型:更快获得成果,简化IT (5)利用CHANGHONG CHI超融合基础架构加快IT转型 (6)完全转型为混合云 (7)创新而不是集成 (7)超融合基础架构 (8)CHANGHONG超融合基础架构平台 (11)CHI3000超融合系统 (12)CHI3000超融合系统安全性与合规性 (15)CHI3000超融合系统硬件体系结构 (16)CHI3000超融合系统群集 (17)CHI3000超融合系统型号和规格 (17)CHI3000超融合系统节点 (18)CHI3000超融合系统扩展 (20)CHI3000超融合系统网络 (20)CHI3000超融合系统软件体系结构 (22)系统管理 (23)HCI Manager系统软件 (23)HCI Manager (24)可由客户升级的软件 (24)2VMware vSphere (25)VMware vCenter Server (25)VMware vSphere ESXi (26)vCenter Server与ESXi主机之间的通信 (26)虚拟机 (27)虚拟网络 (28)vMotion 和虚拟机移动性 (29)vSphere High Availability (HA) (30)vSAN (33)磁盘组 (34)混合和全闪存差异 (35)闪存耐用性 (36)见证组件 (36)复制副本 (36)基于存储策略的管理 (SPBM) (37)vSAN 高可用性和故障域 (37)vSAN 延伸群集 (38)使用重复数据消除和压缩的存储效率 (39)擦除编码 (41)集成软件 (42)VMware vSphere Replication (42)CHANGHONG DR RP400VE连续数据保护产品 (43)3前言本技术手册从概念和体系结构方面介绍采用VMware vSAN和 Intel Inside的CHANGHONG CHI超融合系统。
超融合:一体机部署准备工作1. 拿到超融合一体机后,开箱检验,确认一体机型号是否跟客户采购相符,硬盘数量、容量是否相符。
按“装箱单”上面的内容逐项检查。
2. 根据客户业务做好网络规划,请先阅读:超融合几种典型的网络部署方式,下面步骤中所提到的网络部署方案1-6都来源于该文档。
3. 准备交换机和网线,千兆网口对应用千兆交换机,万兆网口对应用万兆交换机,网线要用超六类线。
一般情况(不超过10 台主机)下准备4台24口交换机就够用了,想了解的更详细请查看几种部署方案对交换机的要求4. 跟IT管理员一起做IP规划,分配一些IP地址给超融合使用。
集群通信口:用于主机之间的数据通信,也用于集群管理要考虑3个因素:1.集群通信部分数据通信是广播模式,主机IP必须在同一个子网,尽量使用独立的IP网段,最好用VLAN跟其他网络隔离。
2.要能够在办公区连接到集群IP(与主机IP在同一网段)进行管理。
3.考虑到以后扩容,请预留一定数量的同一网段IP地址。
VXLAN通信口:只用于超融合服务器之间通信,跟外部是物理隔离的,选择比较生僻的IP段即可,不要跟其他网口冲突。
存储通信口:只用于超融合服务器之间通信,跟外部是物理隔离的,选择比较生僻的IP段即可,不要跟其他网口冲突。
业务通信口:物理网口不用配置IP。
如果要用到aNET,比如虚拟路由器,需要找管理员规划IP,在配置虚拟网络时要用到。
上架布网1.建议集群的规模不超过8台主机,放在同一个机柜上,同时在机柜上固定好交换机。
2.集群最大规模20台主机,也建议放在一个机柜。
如果在两个机柜,存储通信的交换机不能串联,也就是所有主机的存储通信口1都接在同一个24口交换机上,存储通信口2接另一24口交换机,或者都接到一个48口交换机。
3.集群规模大于10台主机时,要求虚拟存储通信使用万兆网口和万兆交换机连接。
4.服务器上机柜要用导轨,查看导轨安装指南。
5.按照上一节做好的网络规划来连接网线,如果交换机的数量不足,优先保证存储通信网络用独立交换机,其他网络用不同的VLAN隔离。
H3C UIS-Cell 3000超融合一体机部署手册目录1产品简介······································1-11.1 产品组成······································1-21.2 部署流程······································1-2 2环境搭建······································2-12.2 准备工作······································2-12.2.1 网络规划···································2-12.2.2 网段规划···································2-22.3 搭建集群硬件环境··································2-22.4 首次使用前的配置··································2-32.4.1 修改root 密码·································2-32.4.2 修改系统时间·································2-52.4.3 修改管理网IP 地址·······························2-6 3部署虚拟化集群···································3-13.1 登录管理系统····································3-13.2 配置网络参数····································3-13.3 注册License(可选)································3-43.3.1 设置浏览器··································3-43.3.2 客户端可正常访问互联网注册License ····································································3-63.3.3 客户端无法正常访问互联网注册License ······························································· 3-113.4 创建集群·····································3-15 4部署存储集群···································4-184.1 配置存储网络···································4-184.2 创建集群·····································4-194.2.1 主机存储网络配置······························4-194.2.2 创建集群··································4-214.3 注册License(可选)·······························4-225 集群扩容·····································5-22 6虚拟机使用····································6-256.1 创建虚拟机参数与CAS 对比····························6-256.1.1 存储位置··································6-256.1.2 系统····································6-256.1.3 配置····································6-266.1.4 网络····································6-266.2 虚拟机支持功能··································6-26 7常见问题列表···································7-267.1 各管理软件页面端口································7-267.2 UIS-Cell 页面登陆长时间无响应···························7-261产品简介H3C UIS-Cell 3000 系列超融合一体机包括以下5 款型号:∙H3C UIS-Cell 3010∙H3C UIS-Cell 3010-C1∙H3C UIS-Cell 3010-C2∙H3C UIS-Cell-3020-25SFF-C∙H3C UIS-Cell 3030∙若无特殊说明,本手册中的UIS-Cell 3000 指代H3C UIS-Cell 3000 系列超融合一体机中的任意一款型号。