便携智能露点仪
- 格式:docx
- 大小:18.21 KB
- 文档页数:1
CERMAX ISIssue 11, March 2003 Manual No.97046 43Pages1.1 (4)1.2 (5)1.3 ATEX (5)2.CERMAX IS (7)2.1 (7)2.2 (7)2.2.1 (7)2.2.2 (7)2.3 (8)2.4 (8)2.4.1 (8)2.4.2 (9)3. CERMAX IS (10)3.1 (10)3.2 (11)3.3 (11)3.3.1 (12)3.4 (12)3.4.1 (12)3.4.2 DEW POINT( ) (13)3.4.3 PPM(W)( ) ( ) (14)3.4.4 PPM(V) 1b/mmscf g/m3 %RH (14)3.5 (14)3.5.1 (15)3.5.2 (15)3.5.3 (15)3.5.4 (16)3.5.5 (16)3.5.6 (17)3.5.7 (18)3.6 (19)3.6.1 (Test No.) (20)3.6.2 (20)3.6.3 (20)3.6.4 (21)3.6.5 (21)3.6.6 (21)3.6.7 (21)3.6.8 (22)3.6.9 (22)3.6.10 (23)3.6.11 (23)3.6.12 (23)3.7 (24)3.7.1 (25)3.7.2 (26)3.8 (27)3.9 (29)4.1 (31)4.2 (31)4.3 (32)4.4 (32)5. (33)5.1 (33)5.2 CERMAX IS (33)5.2.1 (34)5.2.2 (34)5.3 (35)6. (38)1 (39)2 MICHELL (40)3 CERMAX IS (42)1.CERMAX IS MICHELL LCD -100 20 -120o C~+30o CCERMAX IS CERMAX IS CERMAX IS CERMAX IS DISPLAY 3.6CERMAX IS CERMAX IS ON ( 4.3 )1.1(NPL) UKAS -75 ~+20ºC( 0179) (NIST)MICHELL MICHELL MICHELL 5.01.2BS EN ISO 9001:1994 Baseefa (2001)B.S.I.&Baseefa(2001)1.3 ATEXCERMAX IS ATEX (94/9/EC) Baseefa (2001) Ltd (Notified body 1180) BS EN 50 014T bs en 50 020 C.E.N.E.L.E.C. Ex II 1G EEx ia IIC 155o C (T3) Baseefa 03ATEX0090XCERMAX IS ATEX (94/9/EC) ATEX worker protection Directive (1999/92/EC)( )(Flat Battery)CERMAX IS(Logging memory full or incorrect instrument setup.) CERMAX IS CERMAX IS/ (Sensor over/under range or inaccurate sensor measurement)1)2)3)4.2.CERMAX IS2.1CERMAX IS2.2CERMAX IS2.2.1CERMAX IS 4.2CERMAX IS SWAGELOK 1/8” 0.5~5Nl/min 30MPa(300barg) 90o2.2.2on/off (Default) (Previous)3. CERMAX IS2.3CERMAX IS field mode laboratory mode 3.7 3.7.10 015 2 2 -80CERMAX IS 2LCD2.4CERMAX IS2.4.1CERMAX IS 4CERMAX ISCERMAX ISCERMAX IS CERMAX IS2.4.2CERMAX IS RS232 3.6 3.7 3 CERMAX IS 9 D3. CERMAX IS3.110 USER SETUP DEFAULT( ) PREVIOUS( )DEW POINT,OVER ICENONEo C o FpsigDEFAULT/PREVIOUSCERMAX ISSENSOR ID C123 C45 CALIBRATED 14:04:99SOFTWARE VERSION B1.80.00 I.S.COPYRIGHT MICHELL INSTRUMENTS LTD.1aUSER SETUP: DEFAULT PREVIOUSBATTERY CHECK OK1b3.2(MAIN DISPLAY) (AUXILIARY DISPLAY)2Stable DP @ Pressure 10.2ºC10.2 °C DPWARNING - LOW BATTERY33.7DATE 14:04:97 TIME 14:25NO LOGGED DATA AVAILABLE43.33CERMAX ISMain Display Main option3.3.1MENU3.4.DP PPM(V)PPM(W)g/m 3Ib/mmscf %RH 3.4.1MAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W)5aMAIN DISPLAY AUX DISPLAY LOGGINGg/m 3lb/mmscf %RHMAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W)63.4.2 DEW POINT( )o C o F KMAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W)7 o F0o C OVER WATER0o C OVER WATERMAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W) 83.4.3 PPM(W)( ) ( )PPM(W)MAIN DISPLAY AUX DISPLAY LOGGING DP PPM(V)PPM(W) N 2 AIR CO 2 H 2 SF 69 PPM(W) 3.4.4 PPM(V) 1b/mmscf g/m 3 %RH PPM(V) 1b/mmscf g/m 3 %rh3.5%rh%rhAuxiliary OptionsMain Option NoneSet Temp Set Press SensorDisplay DPxPPM(V) xPPM(W) xg/m 3x x x lb/mmscf x xx %RHx xxNone. ( ) NONE( ) 21oCSET TEMP CERMAX IS %rhSET PRESS ( ) Set PressSENSOR. DISPLAY.AUX DISPLAY LOGGING MAIN DISPLAY NoneSet Temp Set Press10aAUX DISPLAY LOGGING MAIN DISPLAY Set Press Sensor Display10b ( ) 3.5.1AUX DISPLAY LOGGING MAIN DISPLAY NoneSet Temp °C °F K Set Set Press11 3.5.2%rh (Set temp)(Set Temp) (Set)AUX DISPLAY LOGGING MAIN DISPLAYNoneSet Temp °C °F K Set Set Press12 F 3.5.3(Set)Maximum allowable values Minimum allowable values +200°C -100°C +392°F -148°F 473K +173KAUX DISPLAY LOGGING MAIN DISPLAY NoneSet Temp°C °F K Set -25 Set Press13 -25 3.5.4%rh Set Press PSIG BARG barkPa kPa kPa(Set Press) (Set)AUX DISPLAY LOGGING MAIN DISPLAY NoneSet TempSet Press PSIG BARG kPa Set 100014 BARG 3.5.5Maximumallowable values Minimum allowable values 5880 PSIG 0 PSIG 400 BARG 0 BARG 40,000 kPa 50 kPaAUX DISPLAY LOGGING MAIN DISPLAY NoneSet TempSet Press PSIG BARG kPa Set 3817 381b/mmscf g/m 3 CERMAX IS 1b/mmscf CERMAX IS 1958 kPa bar0 50psig 10 psig 75~300 psig 25 psig 350 500 psig 50 psig 600 1000 psig 100 psig 1200 1500 psig300 psigCEREMAX 13psig bar kPa 10psig CERMAX IS 540psig 500psig 3.5.6( 3.5.4) AUXILIARY DISPLAY( ) (Sensor)%RHg/m 3 lb/mmscf AT PRESSAUX DISPLAY LOGGING MAIN DISPLAY Set Temp Set PressSensor At Press At Atm16 3.5.7(Auxiliary Display)(Sensor)%RHg/m 3 lb/mmscf PRESSAUX DISPLAY LOGGING MAIN DISPLAY Set Press SensorDisplay Press DP17DP @ Pressure 36.5°C10.2°C DPFIELD MODE CAL DUE 04:9818Set Pressure 550 PSIG 10.2°C DPFIELD MODE CAL DUE 04:98233.6CERMAX IS 1000 10000 PC 3.7(LOGGING)Test No. Interval SamplesStart/StopLOGGING MAIN DISPLAY AUX DISPLAY Test No. TextInterval.20aLOGGING MAIN DISPLAY AUX DISPLAYIntervalSamplesStart/Stop20b ( )3.6.1 (Test No.)0 TEST NO 0 Test No.3.6.215 /-TEXT3LOGGING MAIN DISPLAY AUX DISPLAYTest No.Text QUALITY TESTS 3THIS IS MY TESTInterval.213.6.3LOGGING MAIN DISPLAY AUX DISPLAYTest No.TextInterval 1 2 3 5 10 15 30 45 60 mins223.6.4999 10000LOGGING MAIN DISPLAY AUX DISPLAY Test No. TextInterval Samples 2523 3.6.53.6.6START( )LOGGING MAIN DISPLAY AUX DISPLAY Interval SamplesStart/Stop Stop Start Delay Start 00:0024 3.6.7(Delay Start) (24 ) 8:00am 2 30 10:30 (Delay Start) 9 17:00(5:00pm) (Delay Start)Start/Stop(Delay Start)15LOGGING MAIN DISPLAY AUX DISPLAY Interval SamplesStart/Stop Stop Start Delay Start 14:3025 14:30(2:30pm) 3.6.8CERMAX ISStart/Stop STOPLOGGING MAIN DISPLAY AUX DISPLAY SamplesStart/Stop Stop Start Delay Start 14:3026 3.6.9/ ( )Date 14:04:97 Time 14:48NO LOGGED DATA AVAILABLE273.6.10( 3.7 PC )’None’ / (Stable/Responding) 0= (Stable) 1= (Responding) 3.6.114Enter Sample No:5 14:04:97 17% No Time Frostpoint°C PSIG 75 16:23 -15.38 0.0 76 16.24 -15.40 0.029 5 3.6.12Memory gaugeLOGGING MAIN DISPLAY AUX DISPLAYTest No. 5 TextInterval30Test Pt:5 QUALITY TEST 1 14:04:97 9% No Time Frostpoint°C PSIG 0 16:23 -23.39 0.0 1 16.24 -24.400.0313.7CERMAX IS RS232 9600baud 8data bits 1 start bits 1 stop bit no parity IDCERMAX IS COPYRIGHT MICHELL INSTRUMENT LTD. CERMAX IS UNIT ID FREDSERIAL NO.C123C45SOFTWARE VERSION R190.00HELPCLCK? READ THE REAL TIME CLOCK DATE=xx:xx:xx SET DATE TIME=xx:xx:xx SET TIME LANG=US US SETUP LANG=UK UK SETUPKDLY=xx SET KEY REPEAT DELAY IN 10mS UNITS (DEFAULT 100mS) KRPT=xx SET KEY REPEAT RATE IN 10mS UNITS (DEFAULT 100mS) ERAS CLEAR THE LOGGING MEMORY FIELD SPOT CHECK MODE LABUSELABORATORY MODEID= ENTER A MACHINE ID (MAXIMUM 20 CHARACTERS) LOAD DOWNLOAD LOGGED DATA TO TERMINAL 3.7.1CLCK? DATE IS 16:04:97 TIME IS 16:43:15 DATE=17:04:97 DATE IS 17:04:97TIME=10:30:00 TIME IS 10:30:00 LANG=UK or LANG=US LANGUAGE = UK or LANGUAGE = US FIELD UNIT CONFIGURED FOR SPOT CHECKLABUSE UNIT CONFIGURED FOR EXTENDEDMEASUREMENT MODECERMAX IS 10KDLY=10INITIAL KEY REPEAT DELAY SET TO 100 mS100CERMAX IS 10 100 KRPT=10 KEY REPEAT INTERVALSET TO100 mSPCLOAD DOWNLOADING LOGGINGFILES - PLEASE WAIT…DOWNLOAD SUCCESSFULCERMAX IS ERAS CLEARING THE LOGGINGMEMORY WILL TAKE AFEW SECONDS - PLEASEWAIT….LOGGING MEMORYCLEAREDID=FRED Unit ID is FREDLOCK OKUNLOCK OK3.7.2PC COM1 CERMAX IS RS232CERMAX ISWICDOWS 95 HYPER TERMINALHYPER TERMINAL CERMAX ISHYPER TRMCERMAX ISOKConnect COM1OKCOM1Baud 9600Data bits 8Parity NONEStop bits 1Flow control HardwareOKUNIT ID FREDTest Pt:0 MY TEST 15:04:97No Date Time LB/MMSCF PSIG0 15:04:97 14:59 2.30 1000.01 15:04:97 15:00 2.31 1000.0||8 15:04:97 15:02 2.28 1000.09 15:04:97 15:03 2.28 1000.03.8Cermax ISUKASTest HygrometerGenerated Dew point°CDew pointTemperature°CSensorTemperature°CCorrectionRequired°CExpandedUncertainty°C-39.89 -40.11 -20 +0.22 ±0.26-20.10 -20.31 0 +0.21 ±0.220.39 0.20 21 +0.19 ±0.18Generated Dew point°C Instrument Display°C-40.1 -40.2-20.1 -20.10.2 0.1Cermax IS(Calibration Correction)(Calibration Correction)Ref DP( ) ( )Cermax IS DP(Cermax IS ) Cermax IS ) +20o C~-100o C dp 13 Ref DP Cermax IS DP-20o C~+10o C Ref DP Cermax IS DP3.9CERMAX IS1.2.CERMAX IS 2.4.112 141.2. CERMAX IS LOW BATTERY WARNING MICHELL3.4.4.4.14.2CERMAX ISMICHELLCERMAX IS 1/8” PTFE0.5~5L/min4.34.2CERMAX IS 15~90 CERMAX ISON RESPONDINGRESPONDING STABLE( )84.4CERMAX IS MICHELLCERMAX IS IS5.5.1CERMAX IS UKASCermax IS Cermax ISCERMAX ISCERMAX IS CERMAX IS 5.25.2 CERMAX ISCERMAX ISMICHELL CERMAX IS5.2.1CERMAX IS1. RS2322. 8 363.CERMAX IS4. CERMAX IS 3 3 365.6. 1/8” CERMAX IS7. CERMAX IS MICHELL5.2.21. 1/8”2.3. 1/8”4.5. CERMAX IS6.85.3EPROM EPROM EPROM EPROM5.3.1 2.15.3.2 IC145.3.3 EPROM IC145.3.4 85.3.5SETUPMARKET=USLANG=US5.3.6 CERMAX ISMICHELL36 Cermax IS6.MICHELL3161/8” SWAGELOK240 64 LCD4 40 LCD-100o C~+20 o C-120o C~+30o C-60~+20o C, 1o C-100~60o C; 2o C0.1 o C 3o C , o F, Kppm(v)ppm(w)gm-3lb/mmscf0~20mA 4~20mA10,000 RS2326V2412 14250mm 300mm 150mm3kgIP65 NEMA4-20~+50o C-40~+70o C30MPa0.5~5L/min1MICHELL CERMAX IS MICHELL2 MICHELL Michell Instruments LtdNuffield Close, Cambridge, CB4 1SS, UK Tel: +44 (0)1223 434800Fax: +44 (0)1223 434895email: i nfo@web: Michell Instruments GmbH Industriestrasse 27, D-61381 Friedrichsdorf GermanyTel: +49 6172 5917-0Fax: +49 6172 591799email: info@michell.deweb: www.michell.deMichell Instruments SARL4 rue du Docteur Heulin, 75017 Paris FranceTel: +33 (0)1 42 26 01 24Fax: +33 (0)1 42 26 01 37email: i nfo@michell.frweb: www.michell.frMichell Instruments BVKastanjelaan 18M, 2982 CM RidderkerkThe NetherlandsTel:+31 (0)180 466460Fax:+31 (0)180 415623email: info@michell-instruments.nlweb: www.michell-instruments.nlMichell Italia SRLVia Capecelatro 10, 20148 MilanItalyPhone: +39 (0) 024 047194Fax: + 39 (0) 024 *******E-mail: info@michell.itWeb: www.michell.itMichell Instruments Shanghai OfficeUnit A9112, Jia Hua Shang Wu Zhong Xin 808 Hong Qiao Lu, Xu Hui, Shanghai 200030 P R ChinaPhone: +86 (0)21 6448 0152Fax: +86 (0)21 6447 9417E-mail: michellasia@Michell Japan KKMusashino Center Building, 1-19-18 Nakacho, Musashino Tokyo 180- 0006JapanPhone: +81 422 502600Fax: +81 422 521700E-mail: NokeiKWN@web: 3 CERMAX IS1) 1 2L/mina) CERMAX IS b) CERMAX IS,2) Field Mode( ) Lab Mode( ) USER SETUP:DEFAULT FIELD MODE LAB MODE3)RESPONDINGDEW POINT AT ATMOSPHERIC CERMAX IS4) 3 0.4 STABLE 5~105)MICHELL +86 0 21 64479417 64480152 michellasia@。
便携式露点仪的工作原理如何选择便携式露点仪以确保工作准确可靠【引言】露点是指在固定温度下,空气中所含水分饱和度达到100%时所对应的温度。
便携式露点仪是一种可以帮助我们测量和监控空气中的水分含量的仪器。
它的工作原理主要涉及温度和湿度的测量,通过计算水分的饱和度来得出露点温度。
本文将深度探讨便携式露点仪的工作原理,以及如何选择一款准确可靠的仪器。
【主体部分】【正文1】便携式露点仪是一种可以测量空气中水分含量的仪器。
它通过测量空气中的温度和湿度,计算出水分的饱和度,并通过相关算法得出露点温度。
这种仪器的工作原理基于气体的物理性质和空气中的水分分子的行为。
【正文2】便携式露点仪的工作原理可以简单分为三个步骤:温度测量、湿度测量和饱和度计算。
1. 温度测量:便携式露点仪内置了温度传感器,可以准确测量空气的温度。
温度传感器可以是热电偶或热敏电阻。
通过测量空气的温度,我们可以了解到达露点所需的条件之一。
2. 湿度测量:为了确定空气中水分含量的饱和度,便携式露点仪需要准确测量空气的湿度。
这通常通过湿度传感器来实现,湿度传感器可以是电容式、电阻式或电化学式的。
无论是哪种传感器,都可以根据气体中的水分分子与传感器表面之间的相互作用来测量湿度。
3. 饱和度计算:通过测量温度和湿度,便携式露点仪可以计算出空气中水分的饱和度。
饱和度是指空气中所含水分与饱和水含量的比值,通常以百分比表示。
根据相关的饱和度定表,仪器可以得出空气中水分的饱和度和对应的露点温度。
【正文3】在选择便携式露点仪时,我们应该考虑以下几个因素来确保仪器的准确性和可靠性。
1. 传感器质量:便携式露点仪的温度和湿度传感器是关键组件,直接影响仪器的测量精度和可靠性。
我们应选择品牌知名、质量可靠的传感器,以确保仪器的测量结果准确稳定。
2. 仪器精度:便携式露点仪的精度是另一个重要的选择因素。
我们应该选择具有较高精度的仪器,以确保测量结果的准确性。
通常,精度以±X℃或±X%RH表示,X代表具体数值。
便携式露点温度分析仪安全操作及保养规程1. 引言便携式露点温度分析仪是一种用于测量空气中水分含量的设备,广泛应用于工业生产、实验室研究等领域。
为了确保仪器正常运行和使用者的安全,本文档将介绍便携式露点温度分析仪的安全操作及保养规程。
2. 安全操作规程2.1 前期准备在使用便携式露点温度分析仪之前,需要做一些前期准备工作,以确保仪器和使用环境的安全。
2.1.1 检查仪器完整性在使用之前,仔细检查仪器外观是否完整,并检查所有配件是否齐全。
如发现任何损坏或缺失,应立即联系供应商进行维修或补充。
2.1.2 工作环境检查请确保使用环境符合以下条件:•温度:工作环境温度应在5°C至40°C之间。
•湿度:工作环境湿度应在20%RH至80%RH之间。
•电源:确保使用的电源符合仪器规格要求,并接地正常。
2.2 操作步骤在正式操作便携式露点温度分析仪时,请按照以下步骤进行。
2.2.1 通电前检查在通电前,请确保以下几点:•仪器连接正常:检查所有电缆、管道等连接是否牢固。
•无漏电现象:检查电缆是否磨损或暴露,如有损坏应立即更换。
•传感器检查:检查传感器是否清洁,如有沉积物应用干净的布擦拭。
2.2.2 仪器通电按照供应商提供的操作手册,按序打开仪器电源,并等待其启动完成。
2.2.3 设置参数根据实际需要,设置便携式露点温度分析仪的相关参数,如测量范围、报警值等。
2.2.4 进行测量将便携式露点温度分析仪放置在待测区域,等待足够时间进行测量。
期间请避免人为干扰。
2.2.5 记录结果根据仪器显示的数据,记录测量结果,并根据需要进行分析和处理。
2.3 关机及清洁2.3.1 关机步骤使用完毕后,应按照以下步骤关机:•停止测量:按停止测量按钮或关闭相应软件。
•断电:关闭仪器电源开关。
•断开连接:断开与外部设备的连接。
2.3.2 清洁操作定期清洁仪器可以保持其正常运行。
但在进行清洁前,请务必完全关机,并且按照以下步骤进行:•使用干净的软布轻轻擦拭仪器外壳和显示屏。
天燃气便携式露点仪安全操作及保养规程天燃气便携式露点仪是一种常用的仪器设备,它可以准确地检测出空气中的水分含量,并据此来计算空气的露点温度。
在使用天燃气便携式露点仪的过程中,我们需要严格遵守安全操作规程,以确保人身安全和仪器正常运行。
本文将详细介绍天燃气便携式露点仪的安全操作及保养规程,以供大家参考。
一、前期准备在使用天燃气便携式露点仪之前,我们需要做好一些准备工作,以确保仪器的正常运行和使用者的安全。
1. 环境准备在进行检测之前,应该确保检测场所的环境符合以下要求:•温度和湿度稳定且符合仪器使用说明书规定的范围。
•环境中无可燃气体、腐蚀性气体或其他有害气体。
2. 仪器检查在使用天燃气便携式露点仪之前,需要进行一次全面的检查,以确保仪器处于良好的运行状态:•检查仪器外观是否完好,电池是否齐全,连接线是否紧固。
•检查传感器是否干净,如有污垢应及时清洁。
•检查露点仪是否能够正常工作,如有异常应及时处理。
二、安全操作在使用天燃气便携式露点仪时,必须遵守以下安全操作规程,以确保人身安全和仪器正常运行。
1. 保持稳定在使用天燃气便携式露点仪时,应将其放置在平稳的表面上,不要放置在易滑动或不平稳的表面上,以免意外倾斜导致损坏仪器或其他意外事故。
2. 防止冲击天燃气便携式露点仪应存放在干燥、通风、无冲击的场所,不应受到剧烈的撞击或振动,以免损坏仪器或对检测结果产生影响。
3. 避免高温天燃气便携式露点仪应存放在阴凉、干燥的环境中,避免暴露在高温环境中,以免对仪器产生影响。
4. 防止水浸天燃气便携式露点仪不能接触水或其他液体,以免对仪器产生影响。
5. 避免振动在使用天燃气便携式露点仪时,应避免冲击、振动等可能影响检测精度的因素,以确保检测结果的准确性。
6. 充电注意事项•请使用原装充电器,避免使用不兼容的充电器。
•充电时,应选择阴凉和通风的地方,避免阳光直射和高温环境。
•充电时,请勿离开充电器和充电的设备,以防止电路短路等意外情况。
常见问题1.什么是露点?露点温度用于衡量气体中的水气含量。
水具备这样一种特性:能够在多种条件下以液体、固体或气体的形式存在。
为了解水蒸气的性质,首先要知道气体的一般性质。
对于任何气体混合物而言,总压等于所有组分气体的分压之和。
这就是道尔顿定律,其表示如下:P 总和 = P 1 + P 2 + P 3 …混合物中任何气体的量都可以用压力来表示。
空气的主要成分是氮气、氧气和水气,因此大气总压由这三种气体的分压组成。
虽然氮气和氧气的浓度较为稳定,但水气的浓度变化很大,必须通过测量来确定。
压缩空气中的露点常见问题1.什么是露点?2.露点与霜点有何区别?3.露点与“压力露点”有何区别?4.压力对露点有什么影响?5.为什么了解压缩空气中的露点很重要?6.压缩空气中露点温度的一般范围是多少?7.压缩空气的质量标准是什么?8.如何可靠地测量压缩空气中的露点?9.露点传感器出现故障的警告信号是什么?10.应该多久检查或校准一次露点传感器?维萨拉 DRYCAP ® DM70 便携式手持露点仪水气的最大分压随温度变化而变化。
例如,温度为 20 °C 时,水气的最大分压为 23.5 mbar 。
23.5 mbar 被称为 20 °C 时的“饱和水气压力”。
在 20 °C 的“饱和”环境下,添加更多水气会发生冷凝。
这种冷凝现象可用来测量水气含量。
水气浓度未知的气体经过一个温度受控的表面。
将表面冷却,直至形成冷凝。
冷凝形成时的温度称为“露点温度”。
因为温度与饱和水气压力之间存在独特的相关性(请注意,水气的最大分压,又称“饱和水气压力”,随温度变化而变化),所以测量气体的露点温度就可以直接测量水气的分压。
知道露点温度,就可以计算出或查到对应的饱和水气压力。
下表显示了一些温度值及其对应的饱和水气压力值:2.露点与霜点有何区别?露点 (Td) 是含水气的气体在恒压下达到饱和时的温度。
这是相对于冰点以上的温度而言的,此时表面冷凝物是液态水。
便携式露点仪安全操作规定在使用便携式露点仪进行测试之前,请务必按照以下安全操作规定进行操作。
这些规定将确保您和他人的安全,并防止仪器损坏。
1. 使用正确的电源便携式露点仪通常由电池供电。
请使用同样品牌和型号的电池,以确保设备能够持续稳定地工作。
如果您不确定哪种电池适合您的露点仪,请查看用户手册或者向制造商询问。
2. 避免电击露点仪可能面临电击风险。
在操作设备之前,请确保您的手部干燥,并避免手部接触另一个接地的表面。
要在使用仪器前执行接地最佳实践,例如在操作时使用静电消除器或接地垫。
3. 避免潮湿环境便携式露点仪通常用于测试水汽。
因此,避免在潮湿的环境中使用地址,这样可以保证精度,并延长设备的寿命。
如果您必须在潮湿环境下使用露点仪,请使用适当的保护措施,例如遮阳伞或人造覆盖物。
4. 避免高温、寒冷环境露点仪需要工作在设计温度范围内,以确保测试结果准确可靠。
在高温或寒冷环境下使用设备可能会损坏测试结果的准确性。
请在使用设备之前检查当前实验室或测试环境的温度,并确保仪器设计温度范围内。
5. 避免对设备造成物理损害便携式露点仪通常较为脆弱,必须小心使用。
在使用设备时,必须避免将其摔落或碰撞,并始终将设备放置在稳定的表面上。
如果您必须搬运设备,请遵守设备的操作手册中提供的有关设备搬运和运输的指示。
6. 保证清洁保证设备的清洁非常重要,因为灰尘和污垢可能会影响设备的性能。
用干净的棉布轻轻擦拭露点仪,并使用符合要求的溶液或化学剂进行清洁。
7. 确保良好的卫生条件露点仪常用于医疗、食品、制药和化工行业等领域。
因此,请在测试之前保证良好的卫生条件,在使用前使用适当的消毒剂和工具,消毒测试前需要接触试剂的所有区域。
8. 遵守设备选配规范在操作设备时,请遵守设备选择规范,不得依据个人喜好或偏见任意选择或更改设备。
此外,请严格遵守制造商提供的有关设备使用和保养的指示。
如果您有任何疑问,请联系制造商的客户服务人员或技术支持部门以获取更多信息。
便携式/台式露点仪DPT-600生产厂家:美国菲美特公司介绍:D P T-600便携式/台式露点仪是采用最先进的纳米微孔金属氧化膜露点传感器生产的现场露点分析仪,能够在-110℃~+20℃的露点温度范围内快速准确地测量气体的水分含量。
应用领域:石化、电力、制药、工业气体、热处理、航空、天然气、干燥设备和医疗。
主要特点:轻巧易于携带,同时可用于台式可编程数据记录可充电长寿命锂电池供电带USB数据输出,可选4~20mA电流输出可选PVA仿真软件在PC机上模拟仪器的操作多参数显示:℃(dp)、(dp)、ppmV、ppmW、μB水蒸气压力、克/每立方米、LBS等.BS等技术参数:露点传感器测量范围:-110℃~+20℃精度:±2℃响应时间:3分钟95%的阶跃变化(由干到湿)气体流量:>1L/M温度传感器测量范围:-40℃~+70℃精度:±2℃压力传感器(可选)测量范围:0~150PSIA(10bar)±1%,接触被测气体材质为316L不锈钢流量计材质大部分为苯乙烯丙烯晴,最大压力为3.4Bar(此压力限制是指排气口的压力)人机工程设计易于携带或台式摆放,重量仅为1.6公斤易读的图形,液晶显示,背光亮度用户可调自动缩放趋势图,可用来判断测量值是否稳定内置详细的帮助文件便于用户使用电池省电模式可由用户自定义自动关机时间,也可完全关闭此模式内置的压力测量和压力修正功能,可同时显示常压露点和压力露点用户可选择带或不带密码锁定内置备份电池电源支持的时钟日历数据记录:可记录单点或多点数据,内容包括:露点、温度和压力(内存>4000点)电路提供带有USB接口的通用外置交流电源适配器(100-240VAC50-60Hz)可充电的锂离子电池,用USB接口或电源适配器充电采样系统和传感器与电气接口和接地都是隔离的传感器分辨率:1pF产生小于0.01˚C外部电源和I/O:USB mini B插口,带密封帽达到IP67/IP68防护等级机械进/出器口采用1/8”Swagelok卡套接头内部管路全采用316不锈钢和聚四氟乙烯材质,不锈钢测量腔内部的面积小,便于快速响应仪器外壳采用挤压铝型材,尺寸:199×162×84mm(L×W×H)重量:1.6kg操作温度-20~+60℃应用领域:石化、电力、制药、工业气体、热处理、航空、天然气、干燥设备和医疗。
便携式露点仪有哪些运用场景?首先,让我们来了解一下便携式露点仪。
露点仪是一种测量空气湿度的设备,它可以通过测量空气中的露点温度,来反映空气的湿度状况。
而便携式露点仪,顾名思义,是一种可以随身携带的露点仪。
这种设备通常采用先进的传感器技术,能够快速、准确地测量空气湿度,并且具有体积小、重量轻、操作简便等优点。
那么,便携式露点仪有哪些应用呢?在工业领域,它被广泛应用于控制生产过程中的湿度。
例如,在制药、化工、食品等行业中,对生产环境的湿度要求非常严格。
通过使用便携式露点仪,可以实时监测环境湿度,及时调整设备运行状态,保证产品质量。
HT-PD310便携式露点仪采用进口薄膜电容传感器,结合了当今世界先进的超低功耗微控制器技术,具有响应速度快、灵敏度高、重复性好等特点。
广泛应用于石油、化工、干燥剂制造商和用户、电力系统露点检测、半导体制造、干燥工业、食品工业、塑料基片干燥、机械制造和空分和其它行业各种气体中微量水分含量的便携分析。
产品特点:段码屏显示,显示直观,操作简单方便;采用进口薄膜电容传感器,具有测量范围宽、精度高、稳定性好、响应速度快、抗冷凝等特点;结构设计新颖,体积小巧、造型美观;独特的气路设计,有良好的气密性、防渗透性和抗吸水性;测量方便,可在任何场合,对任何允许可测气体直接快速测量;用户可根据需要任意设置显示方式为℃或PPm;内置大容量锂电池,充一次电可连续使用7天(带泵型)以上,非带泵型可连续使用30天以上;配置干燥剂,有效保证低端测试的响应时间。
便携式露点仪是一种功能强大、应用广泛的设备。
特别是在工业生产能为我们提供实时的湿度信息,帮助我们更好地应对各种情况。
在未来,随着技术的不断发展,我们相信便携式露点仪将会在更多领域发挥出更大的作用,为我们的生活带来更多的便利和舒适。
便携智能露点仪
一、采购内容:便携智能露点仪(非手持)数量:1台
二、技术要求:
1.传感器:电容式露点仪
2.背景气体:N2或其他惰性气体、环境混合气体
3.量程:-80℃-﹢20℃
4.精度:≤±2℃
5.重复性:≤1℃
6.零点漂移:±1%FS/7d
7.量程漂移:±1%FS/7d
8.样气流量:≤1L/min
9.供电方式:可直接供电也可使用电池,充电一次可连续使用不小于8小时
10.采样方式:通入式和抽取式,
11.其他要求:a.配置内置泵
b.随机附省级计量机构检定证书
c.供货周期:≤10个工作日
三、验收标准:
1.符合技术要求。
2.随机附检定证书,检定结果为合格。
四、付款方式:
无预付款,产品验收合格以后,乙方开具全额增值税专用发票,收到发票以后,10个工作日付合同总额95%,质保金5% 。