T h e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d /o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n .T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s .I t i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f t h e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f .N e i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n .Product data sheetCharacteristicsABL8WPS24200regulated SMPS - 3-phase - 380..500 V AC -24 V - 20 AProduct availability: Stock - Normally stocked in distribution facilityMainRange of product Phaseo Product or component typePower supplyPower supply type Regulated switch modeInput voltage 380...500 V AC three phase L1, L2, L3Output voltage 24 V DC Rated power in W 480 WProvided equipment Power factor correction filter IEC 61000-3-2Power supply output current20 AOutput protection typeAgainst overload manual or automatic reset Against overvoltage 30...32 V, manual reset Against short-circuits manual or automatic reset Against undervoltage tripping if U < 21.6 V Thermal automatic resetAmbient air temperature for operation122…140 °F (50…60 °C) with derating factor)-13…122 °F (-25…50 °C) without)ComplementaryInput voltage limits 320...550 V Network frequency 47...63 Hz Inrush current 25 A 2 ms Cos phi 0.65Efficiency92 %Output voltage limits 24...28.8 V adjustable Power dissipation in W 38.4 W Line and load regulation 1...3 %Holding time>= 18 ms 400 V Permissible temporary current boost 1.5 x In for 4 s)Connections - terminalsDiagnostic relay removable screw terminal block 2 x 2.5 mm²Input connection screw type terminals 3 x 0.5...3 x 4 mm² AWG 22...AWG 12Input ground connection screw type terminals 1 x 0.5...1 x 4 mm² AWG 22...AWG 12Output connection screw type terminals 4 x 0.5...4 x 10 mm² AWG 22...AWG 8MarkingCEMounting support 35 x 7.5 mm symmetrical DIN rail 35 x 15 mm symmetrical DIN rail Operating position VerticalOperating altitude 6561.68 ft (2000 m)Output coupling Series ParallelName of testElectrostatic discharges EN/IEC 61000-4-2Induced electromagnetic field EN/IEC 61000-4-6Magnetic field EN 61000-4-8Primary outage IEC 61000-4-11Radiated electromagnetic field EN/IEC 61000-4-3Rapid transient IEC 61000-4-4Surge EN/IEC 61000-4-5Conducted emissions on the power line EN 55022 class B Radiated emissions EN 55022 class BHarmonic current emission EN/IEC 61000-3-2Status LED Output voltage 1 LED green and red)Output current 1 LED green, red and orange)Depth 6.30 in (160 mm)Height 5.63 in (143 mm)Width 3.78 in (96 mm)Net weight 3.53 lb(US) (1.6 kg)EnvironmentMTBF reliability320 V with UTE C80-810550 V with UTE C80-810Product certifications CCSAusEACULRCMStandards CSA C22.2 No 60950-1UL 508Environmental characteristic EMC EN 61000-6-1EMC EN 61000-6-3EMC EN 55024EMC EN/IEC 61000-6-4EMC EN/IEC 61204-3Safety EN 61204-4Safety EN/IEC 60950-1Safety SELVIP degree of protection IP20 EN/IEC 60529Ambient air temperature for storage-40…158 °F (-40…70 °C)Relative humidity0…90 % during operation0…95 % in storageOvervoltage category Class I VDE 0106-1Dielectric strength3500 V between input and ground4000 V between input and output500 V between output and groundOrdering and shipping detailsCategory22525 - ABL8 AND ABL7 POWER SUPPLIEDiscount Schedule CP12GTIN00785901666363Package weight(Lbs) 2.12 kg (4.67 lb(US))Returnability YesCountry of origin PHOffer SustainabilitySustainable offer status Green Premium productREACh Regulation REACh DeclarationEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)EU RoHS Decla-rationMercury free YesRoHS exemption information YesChina RoHS Regulation China RoHS DeclarationEnvironmental Disclosure Product Environmental ProfileCircularity Profile End Of Life InformationContractual warrantyWarranty18 monthsDimensions DrawingsRegulated Switch Mode Power Supplies DimensionsConnections and SchemaRegulated Switch Mode Power SupplyInternal Wiring DiagramRegulated Switch Mode Power SupplyLine Supply Wiring DiagramThree-phase (L1-L2-L3) 3 x 380 to 500 VRegulated Switch Mode Power SuppliesSeries or Parallel ConnectionSeries Connection(1)Two Shottky diodes Imin = power supply In and Vmin = 50 VParallel ConnectionNOTE: Series or parallel connection is only recommended for products with identical references.For better availability, the power supplies can also be connected in parallel using the ABL8RED24400 Redundancy module.Performance CurvesRegulated Switch Mode Power SuppliesDeratingThe ambient temperature is a determining factor that limits the power an electronic power supply can deliver continuously. If the temperature around the electronic components is too high, their life will be significantly reduced.The nominal ambient temperature for the Universal range of Phaseo power supplies is 50°C. Above this temperature, derating is necessary up to a maximum temperature of 60°C.The graph below shows the power (in relation to the nominal power) that the power supply can deliver continuously, depending on the ambient temperature.X Maximum operating temperature (°C)ABL 8RPM, ABL 8RPS, ABL 8WPS mounted verticallyDerating should be considered in extreme operating conditions:●Intensive operation (output current permanently close to the nominal current, combined with a high ambient temperature)●Output voltage set above 24 Vdc (to compensate for line voltage drops, for example)●Parallel connection to increase the total powerRegulated Switch Mode Power SupplyLoad LimitManual Reset Protection Mode(1)Boost 4sAutomatic Reset Protection Mode(1)Boost 4s“Boost” Repeat AccuracyThis type of operation is described in detail in the user manual, which can be downloaded from the website.。
Installation InstructionsArmorPOINT™ 24V DC Analog Output ModulesCatalog numbers 1738-OE2CM12, 1738-OE2VM12, Series A Table of ContentsTopic Page Important User Information2 Environment and Enclosure3 Prevent Electrostatic Discharge3 About the Modules4 Mount the I/O Base5 Install the Module6 Remove the Module from the Mounting Base6 Wire the Modules7 Communicate with the Module8 Interpret Status Indicators9 Specifications112 ArmorPOINT™ 24V DC Analog Output ModulesImportant User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at/literature/) describes some important differences betweensolid-state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable.In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams.No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual.Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.Throughout this manual, when necessary, we use notes to make you aware of safety considerations.Publication 1738-IN004B-EN-E - July 2011ArmorPOINT™ 24V DC Analog Output Modules 3Publication 1738-IN004B-EN-E - July 2011Environment and Enclosure Prevent Electrostatic DischargeATTENTION: This equipment is intended for use in overvoltage Category IIapplications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft)without derating.This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11. Without appropriate precautions, there may be difficultieswith electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances.This equipment is supplied as enclosed equipment. It should not requireadditional system enclosure when used in locations consistent with theenclosure type ratings stated in the Specifications section of this publication.Subsequent sections of this publication may contain additional informationregarding specific enclosure type ratings, beyond what this product provides,that are required to comply with certain product safety certifications.In addition to this publication, see:•Industrial Automation Wiring and Grounding Guidelines, Rockwell Automation publication 1770-4.1, for additional installation requirements.•NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure.ATTENTION: This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelineswhen you handle this equipment:•Touch a grounded object to discharge potential static.•Wear an approved grounding wriststrap.•Do not touch connectors or pins on component boards.•Do not touch circuit components inside the equipment.•Use a static-safe workstation, if available.•Store the equipment in appropriate static-safe packaging when not in use.4 ArmorPOINT™ 24V DC Analog Output ModulesPublication 1738-IN004B-EN-E - July 2011About the ModulesThe ArmorPOINT I/O family consists of modular I/O modules. The sealed IP67 housing of these modules requires no enclosure. Note that environmental requirements other than IP67 may require an additional appropriate housing. I/O connectors are sealed M12 style. The mounting base ships with the module. The 1738-OE2CM12 module is shown here.Connector M12-A Connector M12-BLED indicatorsArmorPOINT™ 24V DC Analog Output Modules 5Publication 1738-IN004B-EN-E - July 2011Mount the I/O BaseT o mount the base on a wall or panel, use the screw holes provided in the base.A mounting diagram for the ArmorPOINT base with adapter is shown here.Install the mounting base as follows:y out the required points as shown above in the drilling dimension diagram.2.Drill the necessary holes for M4 (#8) machine or self-tapping screws.3.Mount the base using M4 (#8) screws.4.Ground the system using the ground lug connection. The ground lug connection is also a mounting hole.ATTENTION: The ArmorPOINT I/O module must be mounted on a groundedmetal mounting plate or other conductive surface.Mounting baseKeyswitch – set toposition 4 for 1738Ground lug connectionLatching mechanism6 ArmorPOINT™ 24V DC Analog Output ModulesInstall the ModuleT o install the analog output module, proceed as follows:ing a bladed screwdriver, rotate the keyswitch on the mounting base clockwiseuntil the number 4 aligns with the notch in the base.2.Position the module vertically above the mounting base. The module bridgestwo bases.3.Push the module down until it engages the latching mechanism. Y ou hear aclicking sound when the module is properly engaged. The locking mechanismlocks the module to the base.Remove the Module from the Mounting BaseT o remove the module from the mounting base:1.Insert a flat blade screwdriver into the slot of the orange latching mechanism.2.Push the screwdriver toward the I/O module to disengage the latch. The modulelifts up off the base.3.Pull the module off the base.Publication 1738-IN004B-EN-E - July 2011ArmorPOINT™ 24V DC Analog Output Modules 7Publication 1738-IN004B-EN-E - July 2011Wire the ModulesThe wiring instructions for the modules are shown here.IMPORTANT Analog modules have earth grounded metal rings. This should beconsidered when choosing shielded cables and grounding techniques.ATTENTION: Make sure all connectors and caps are securely tightened toproperly seal the connections against leaks and maintain IP enclosure type requirements.(View into connector)Pin 1 Output 0 (M12-A)Output 1 (M12-B)Pin 2 24V DCPin 3 CommonPin 4 CommonPin 5 No connect8 ArmorPOINT™ 24V DC Analog Output ModulesPublication 1738-IN004B-EN-E - July 2011Communicate with the ModuleI/O messages are sent to (consumed) and received from (produced) the ArmorPOINT modules. These messages are mapped onto the processor’s memory. The ArmorPOINT analog output modules produce 2 Bytes of input data (scanner Rx – fault status). They consume 4 Bytes of output data (scanner Tx).Default Data Map for Output ModulesMessage size: 2 Bytes 15141312111009080706050403020100Produces (Scanner Rx)High byte – channel 1 status Low byte – channel 0 status Not used HCA LCA CM CF Not used HCA LCA CM CF Where:HCA = High Clamp Alarm; 0 = No error, 1 = FaultLCA = Low Clamp Alarm; 0 = No error, 1 = FaultCM = Calibration Mode; 0 = Normal, 1 = Calibration modeCF = Channel Fault Status; 0 = No error, 1 = FaultMessage size: 4 Bytes15141312111009080706050403020100Consumes (Scanner Tx)Output channel 0 high byteOutput channel 0 low byte Output channel 1 high byte Output channel 1 low byteArmorPOINT™ 24V DC Analog Output Modules 9Publication 1738-IN004B-EN-E - July 2011Interpret Status IndicatorsIndicator Status for Modules StatusDescription Module status OffNo power applied to device.GreenDevice operating normally.Flashing greenDevice needs commissioning due to missing, incomplete, or incorrect configuration.Flashing redRecoverable fault.RedUnrecoverable fault – may require device replacement.Flashing red/green Device is in work status OffDevice is not online: - Device has not completed dup_MAC-id test. - Device not powered – check module status indicator.Flashing greenDevice is online but has no connections in the established state.GreenDevice is online and has connections in the established state.Flashing redOne or more I/O connections is in timed-out state.Red Critical link failure – failed communication device. Device detected error that prevents it from communicating on the network.Flashing red/green Communication faulted device – the device has detected a network access error and is in communication faulted state. Device has received and accepted an Identity Communication Faulted Request – long protocol message.1738-OE2CM12Module status indicator Network status indicatorI/O status indicators10 ArmorPOINT™ 24V DC Analog Output Modules Indicator Status for ModulesStatus DescriptionI/O status Off Module in CAL mode.Solid green Device operating normally.Flashing green Channel being calibrated.Flashing red1738-OE2VM12 – Low or high clamp.1738-OE2CM12 – Open wire or no power.Solid red1738-OE2VM12 only – No power. Publication 1738-IN004B-EN-E - July 2011ArmorPOINT™ 24V DC Analog Output Modules 11Publication 1738-IN004B-EN-E - July 2011SpecificationsArmorPOINT 24V DC Analog Output Modules – 1738-OE2CM12, 1738-OE2VM12AttributeValue Outputs per module2 single-ended, nonisolated Output voltage 1738-OE2V 0V output until communication established 0…10V (user-configurable; 0V under, 5V over) 10V (user-configurable; -0.5V under, 5V over)Output current 0 mA output until communication established 4…20 mA user configurable 0…20 mA user configurableResolution 1738-OE2C 13 bits – over 0…21 mA 2.5 μA/cnt (average value – typical range: 2.3…2.7 μA/cnt)1738-OE2V 14 bits (13 plus sign) 1.28 μV/cnt in unipolar or bipolar modeAbsolute accuracy (1)(1)Includes offset, gain, non-linearity and repeatability error terms0.1% full scale @ 25 °CAccuracy drift w/temp 1738-OE2C – 30 ppm/°C1738-OE2V – 5 ppm/°CResistive load on mA output 1738-OE2C – 0…750 ΩCurrent load on output, max 1738-OE2V – 3 mAConversion type Digital-to-analog converterConversion rate 1738-OE2C – 16 μs1738-OE2V – 20 μsData formatSigned integer12 ArmorPOINT™ 24V DC Analog Output ModulesPublication 1738-IN004B-EN-E - July 2011General Specifications AttributeValue CalibrationFactory-calibrated Mounting base screw torque #8 screw 0.85 Nm (7.5 lb-in.) in aluminum 1.8 Nm (16 lb-in.) in steelIndicators 1 green/red – module status indicator, logic side 1 green/red – network status indicator, logic side 2 green/red – output status indicators, logic sidePowerdissipation,***********1738-OE2C 750 Ω load on each output – 1.23 W 0 Ω load on each output – 1.83 W1738-OE2V 1.0 WThermaldissipation,***********1738-OE2C 750 Ω load on each output – 4.19 BTU/hr 0 Ω load on each output – 6.24 BTU/hr1738-OE2V 3.4 BTU/hrIsolation voltage 50V rms Tested @ 1250V AC rms for 60 sPOINTBus current 75 mA @ 5V DCExternal DC power supply voltage, nom 24V DCExternal DC power voltage range 10…28.8V DCExternal DC power supply current 1738-OE2C 70 mA @ 24V DC (including outputs @ 20 mA)1738-OE2V 35 mA @ 24V DC (including outputs @ 3 mA)Dimensions, HxWxD 31.75 x 66.80 x 107.95 mm (1.25 x 2.63 x 4.25 in.)Weight 0.289 kg (0.637 lb)Wiring category (1) 1 – on signal portsKeyswitch position 4Step Response to 63% of FS24 μs (1)Use this conductor category information for planning conductor routing. Refer to publication 1770-4.1, Industrial Automation Wiring and Grounding Guidelines.ArmorPOINT™ 24V DC Analog Output Modules 13Publication 1738-IN004B-EN-E - July 2011Environmental Specifications Attribute Value Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20…60 °C (-4…140 °F)Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -40…85 °C (-40…185 °F)Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Nonoperating Damp Heat): 5…95% noncondensingVibration IEC60068-2-6 (Test Fc, Operating): 5 g @ 10…500 HzShock, operating IEC60068-2-27 (Test Ea, Unpackaged Shock): 30 gShock, nonoperating IEC60068-2-27 (Test Ea, Unpackaged Shock): 50 gESD immunity IEC 61000-4-2: 6 kV contact discharges 8 kV air dischargesRadiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM @ 80 MHz…2000 MHz 10V/m with 200 Hz 50% pulse 100% AM @ 900 Mhz 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MhzEFT/B immunity IEC 61000-4-4: ±3 kV @ 5 kHz on signal portsSurge transient immunity IEC 61000-4-5: ±2 kV line-earth (CM) on shielded portsConducted RF immunity IEC 61000-4-6: 10Vrms with 1kHz sine-wave 80% AM @ 150 kHz…80 MHzEmissions CSPR 11: Group 1, Class AEnclosure type ratingMeets IP65/66/67 (when marked)14 ArmorPOINT™ 24V DC Analog Output ModulesPublication 1738-IN004B-EN-E - July 2011Certifications Certification (when product is marked)(1)Value CE European Union 89/336/EEC EMC Directive, compliant with:EN 50081-2; Industrial EmissionsEN 50082-2; Industrial ImmunityEN 61326; Meas./Control/Lab., Industrial RequirementsEN 61000-6-2; Industrial ImmunityEN 61000-6-4; Industrial EmissionsC-TickAustralian Radiocommunications Act, compliant with:AS/NZS CISPR 11; Industrial Emissions (1)See the Product Certification link at for Declaration of Conformity, Certificates, and other certification details.ArmorPOINT™ 24V DC Analog Output Modules 15 Notes:Publication 1738-IN004B-EN-E - July 2011Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At /support/, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools.For an additional level of technical phone support for installation, configuration and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit /support/.Installation AssistanceIf you experience a problem within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your product up and running.New Product Satisfaction ReturnRockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.Documentation FeedbackYour comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at /literature/.United States or Canada1.440.646.3434Outside United States or Canada Use the Worldwide Locator at /support/americas/phone_en.html , or contact your local Rockwell Automation representative.United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process.Outside United StatesPlease contact your local Rockwell Automation representative for the return procedure.Publication 1738-IN004B-EN-E - July 2011957824-30Supersedes Publication 1738-IN004A-EN-E - June 2004Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Allen-Bradley, Rockwell Automation, ArmorPOINT, and T echConnect are trademarks of Rockwell Automation, Inc.T rademarks not belonging to Rockwell Automation are property of their respective companies.。
MMT – DC24DP10-35BL使用说明书概述:DC 12V /24V /36V/48DP XXBL系列产品是采用专用模块,使控制和供电完全隔离,避免了低压大电流时对控制系统的干扰。
其优良的线性比例、比较宽的电压输入范围、突出的性能和调速比。
具有稳定、可靠的质量,使其得到广范的应用。
该系列产品适用于电瓶供电或直流供电的野外作业以及低压自动控制的场合。
目前已应用在军工、机器人、低压安全设备、教研设备等领域。
一、主要特点技术参数:1、输入电压:DC 24 V(工作范围18V-36V)2、输出电压:DC 0V----24V3、输出电流:DC 10A 20A 35A4、调速比1:805、环境温度:--10℃~+60℃6、环境湿度:相对湿度≤80RH。
(无结露)7、适用于稀土、永磁和他励电动机8、双闭环PI调节(电流电压)9、采用SMT技术、体积小10、电流设置和限制保护11、瞬时短路保护(50us)12、软启动/软停止设置功能13、快速停止功能14、低速启动力矩大15、可实现远程启停二、产品性能:1、具有较硬的机械特性,静差率1%。
2、具有较宽的调速范围(0—最大)。
3、具有较快的动态响应过程。
4、具有加、减速时自动平滑的过渡过程。
5、较好的挖土机特性,能将过载电流自动限止在设定值电流上。
6、可靠性高,结构紧凑,具有极高的性价比。
三、电位器调整说明(顺时针增大)1、限制调整:TORQUE可以限制驱动板最大输出电流,根据所选马达的额定电流调整该电位器,使驱动板的最大输出电流为马达额定电流的120%~200%。
2、力矩补偿调整:IR COMPIR COMP 电位器用于调整马达工作在不同的负载时,使其转速保持恒定。
3、软启动-----升速时间调整:ACCEL调整ACCEL可以确定马达从初始速度到设定速度的上升斜率(既上升时间,设定时间在0-10秒内可调)。
见图1图14、软停止------降速时间调整(内部已固定):DECEL调整DECEL可以确定电机从最高速度下降到最低转速的下降斜率(既下降时间,设定时间在0-10秒内可调)。
35PISA PISA is an innovative concept for current distribution and protection of 24V load circuits. First, it distributes the current ofa large power source to four lower current output channels and therefore, allows for smaller wires to be used. The second function is to permit only as much current on the outputs so that the input voltage of this unit (which corresponds to the output voltage of the power supply) does not fall below 21V . This ensures a safe and uninterrupted supply voltage for sensitiveequipment, such as PLCs, controls or sensors, when they are connected directly to the same power supply as the PISA module.Less critical loads, that are not affected by short voltage interruptions or that could even be the cause of a fault on the 24V power supply are connected to one of the four current controlled output channels of the PISA module. The protection is independent of the length of the wires or of the power supplies‘ characteristics. All four output channels shutdown simultaneously if the current of one channel or the maximum allowed current of the PISA module is exceeded.All PISA modules have an Output-OK relay contact to provide a status signal. The Reset function provides a means of turning the unit ON/OFF locally as well as remotely. Multiple PISA modules can be shut down simultaneously during a protection event by connecting the Sync terminals.Circuit Protection ModulesProtection ModulesProtection PISA11Controls, PLC(sensitive loads)Motor 1Motor 2Display, MonitorRelays, Solenoids Non NEC Class 2 Circuit NEC Class 2 Circuit 1NEC Class 2 Circuit 2NEC Class 2 Circuit 3NEC Class 2 Circuit 4All ModelsNEC Class 2 Models。
EVP30系列系列----------330W 宽压输入稳压输出DC DC--DC 模块电源模块电源产品产品特性特性特性◆宽输入电压范围: 2:1◆六面金属屏蔽,DIP 封装 ◆隔离1500VDC◆短路保护(自恢复)◆工作温度范围:-40℃~+85℃ ◆符合RoHS 指令 应用范围应用范围无线网络、电信/数据通信、电力系统、工业控制系统、测量仪器仪表、智能化领域等电源系统。
适合于需要实现输入范围波动大,需要电源隔离,布板空间小等设计,并实现产品功能模块化,提高产品可靠性。
产品型号型号型号 输入电压范围输入电压范围输出电压输出电压//输出电流Vo/Io最大容性负载大容性负载((uF)) 效率(TYP) EVP30-12S05 5V / 6000mA 2000 87% EVP30-12S12 12V / 2500mA 470 88% EVP30-12S15 9 – 18 VDC 15V / 2000mA 400 89% EVP30-24S05 5V / 6000mA 2000 86% EVP30-24S12 12V / 2500mA 470 88% EVP30-24S15 18 – 36 VDC 15V / 2000mA 400 90% EVP30-48S05 5V / 6000mA 2000 86% EVP30-48S12 12V / 2500mA 470 89% EVP30-48S15 36 – 72 VDC 15V / 2000mA 400 91% ★EVP30-12D05 ±5V / 3000mA ±1000 88% ★EVP30-12D12 ±12V / 1250mA ±220 90% ★EVP30-12D15 9 – 18 VDC ±15V / 1000mA ±100 91% ★EVP30-24D05 ±5V / 3000mA ±1000 87% ★EVP30-24D12 ±12V / 1250mA ±220 89% ★EVP30-24D15 18 – 36 VDC ±15V / 1000mA ±100 91% ★EVP30-48D05 ±5V / 3000mA ±1000 89% ★EVP30-48D12 ±12V / 1250mA ±220 90% ★EVP30-48D1536 – 72 VDC ±15V / 1000mA±10091%注:加“★”产品研发中,如有其它规格需求,请直接联系我司。
技术参数特性与优点
➢三路高精度电源独立可控输出:30V/3A×2,可切换
2.5V/
3.3V/5V/3A×1,总功率195W
➢5位电压、4位电流显示,最小分辨率:1mV,1mA
➢支持面板定时编程和定时输出功能
➢ 4.3寸真彩TFT-LCD 480×272像素显示
➢三种输出模式:独立、串联、并联模式,提高输出功率范围
➢110V/120/220/230V兼容设计,满足不同电网需求
➢智能型温控风扇,有效降低噪声
➢清晰的图像化界面,具有波形显示功能
➢内部5组系统参数保存/调取,并支持数据存储空间扩展。
➢可通过USB标准接口与PC连接,支持SCPI命令,满足控制和通信需求
设计特色
配备4.3英寸真彩TFT-LCD
显示屏,480x272
像素显示,电压、电流连续可
调。
可实现5组定时设置和输出控
制,可与上位机软件相配合,
满足通信和控制需求。
仪器内部提供5组系统参数保
存空间,支持数据存储器扩展。
01目 录1. 产品介绍 ………………………………………………1.1 产品概述…………………………………………… 1.2 产品展示……………………………………………2. 工作原理…………………………………………………2.1.电力UPS框架结构………………………………… 2.2.正常供电模式……………………………………… 2.3.直流供电模式……………………………………… 2.4.旁路供电模式………………………………………2.5.维修旁路供电模式…………………………………3. 功能单元...................................................... 3.1整流器...................................................... 3.2 逆变器................................................... 3.3 静态开关................................................... 3.4 主控制单元................................................ 3.5 人机操作界面控制单元 (1)4. 电气性能参数…………………………………………1 4.1 单相输入单相输出电气性能参数…………………1 4.2 三相输入单相输出电气性能参数………………15. 安装工程设计……………………………………………1 5.1 环境要求……………………………………………1 5.2电缆规格选择………………………………………… 5.3 UPS系统配电图……………………………………… 5.4 功率电缆连接………………………………………5.5 UPS信号电缆的安装……………………………… 5.5.1信号电缆安装位置示意图……………………… 5.5.2 Rs232监控系统的安装与使用…………………2 5.5.3 Rs485接口信号电缆连接………………………2 5.5.4 无源干接点接口的连接………………………26. 使用与维护……………………………………………………………………………………………4……………………………………………4……………………………………………5…………………………………………………6…………………………………6………………………………………6………………………………………6………………………………………7…………………………………7………………………………………………8………………………………………………8……………………………………………8………………………………………………………………………………………10……………………………0…………………………………………1…………………1………………3……………………………………………4……………………………………………4…………………………………………15………………………………………16………………………………………………………………………19 ………………………19…………………0………………………0...........................0 (2144566667788891010111113141415161819)1920202021026.1 开机前的检查事项………………………………… 6.2 第一次上电开机………………………………… 6.3 工作模式测试…………………………………… 6.4 操作界面介绍…………………………………… 6.5 日常运行管理…………………………………… 6.6日常维护……………………………………………7.ACTIVE POWER (艾泰沃)售前技术服务………………8.ACTIVE POWER (艾泰沃)服务承诺…………………… 8.1服务理念…………………………………………… 8.2服务业绩…………………………………………… 8.3售后服务…………………………………………… 8.4保修内的服务……………………………………… 8.5保修外的服务……………………………………….......................................21.......................................22..........................................22..........................................22..........................................25...................................................26..................27........................27...................................................27 ...................................................27 ...................................................27 .............................................28 (28)03艾泰沃(ACTIVE POWER)公司是领先的电力设备制造商,致力于为中国经济建设提供最可靠的电源支持与保证系统。
T-PB SERIES24VAC POWER SUPPLIESCLASS I & CLASS IIPRODUCT DESCRIPTIONThe T-PB series is comprised of UL Listed (–1 suffix units) and UL Recognized Component (–0 suffix units) power supplies which T -PB series unit includes a green pilot LED which, when illuminated, indicates that the 24VAC output is operational.A DPDT ON/OFF switch is provided in the 115VAC input. This switch disconnects or connects both the H & N of the input power for the 24VAC output.This convenience outlet IS NOT controlled by the ON/OFF switch.A circuit breaker is incorporated in the 24VAC output which must be manually reset if the rated 4.0A (Class I) or 3.0A (Class II)is exceeded and the breaker operates.FEATURES❖ Front visible green power-on (pilot) LED indicator ❖ ON/OFF power switch❖ Circuit breaker protected output❖ Auxiliary non-fused/non-switched convenience line power outlet ❖ 4.0A, 96VA (Class I) and 3.0A, 72VA (Class II) versions available❖ “–0” chassis sub-assembly mount and “–1” full enclosure mounted versions available ❖ Front access plate for controls and auxiliary convenience outlet on “–1” versions ❖ For continuous duty useINSTALLATION WIRING & CONTROLSSpecifications subject to change without notice. | DS-PS-1 B050115 | USA 150702 | Page 1 of 2Specifications subject to change without notice. | DS-PS-1 B050115 | USA 200204 | Page 1 of 2Power Supplies, Class I & II, 115 VAC : 24 VACPRODUCT SPECIFICATIONSMODEL NUMBERS:MAIN OUTPUT POWER:OUTPUT CAPACITY:SUPPLY CLASS:LISTINGS AND APPROVALS:UNIT CONSTRUCTION:OVERALL DIMENSIONS:CONDUIT KNOCKOUTS:(1 Top and 1 Bottom)FRONT ACCESS PLATE:METAL WORK: 16ga CRS (1.5mm) with beige painted fi nish and black silk-screened markings INPUT POWER: 115VAC @ 60HzINPUT CURRENT:1.0A Max for 24VAC main output power only6.0A Max total with 5.0A convenience outlet in full useCONVENIENCE OUTLET: Front accessible 115VAC @ 60Hz, 5.0A MaxMAIN OUTPUT PROTECTION: Front accessible 4.0A @ 32V manual reset circuit breaker MAIN OUTPUT CONTROL: Front accessible DPDT ON/OFF rocker switch POWER ON INDICATOR: Front visible green LED ENVIRONMENTAL: -13°F to 140°F (-25°C to 60°C) @ 85% RH, Non-condensing WIRING: Solid or stranded; #12 to #22 AWG terminals *QQFU = Power Supplies, General Purpose; /2 = Recognized ComponentT-PB 202-1*QQFU.E160579UL 1012Full Enclosure 6.125” (156mm)5.186” (132mm)4.125” (105mm)0.75” (22mm) 4.313” (110mm)1.5” (38mm)T-PB 202-0*QQFU2.E160579UL 1012Chassis Only 4.75” (121mm) 5” (127mm) 3.125” (80mm)T-PB 303-0*QQFU2.E160579UL 1012Chassis Only 4.75” (121mm) 5” (127mm)3.125” (80mm)T-PB 303-1*QQFU.E160579UL 1012Full Enclosure 6.125” (156mm)5.186” (132mm)4.125” (105mm)0.75” (22mm)4.313” (110mm) 1.5” (38mm)HWDHW**********72VA Class II **********96VA Class I Specifications subject to change without notice. | DS-PS-1 B050115 | USA 150702 | Page 2 of 2Specifications subject to change without notice. | DS-PS-1 B050115 | USA 200204 | Page 2 of 2T-PB。
DIN-PW24V1A 24V供电模块概述DIN-PW24V1A供电模块是我公司开发研制的一种智能化强转弱电转换器,功能齐全,适用于智能控制系统等领域。
功能特点♦一键更换模块,自动恢复模块数据和状态♦可设置为最多24个模式的组成部分♦每个回路可设自动控制或百分比控制♦设备可设置记忆保存功能,以记忆最近的回路状态♦采用485总线方式通讯♦标准35mm导轨式安装结构主要技术参数♦工作电压:AC220-250V♦输出电压:24V♦环境条件:工作温度0℃~45℃工作相对湿度20%~90%储存温度-40℃~+55℃储存相对湿度10%~93%♦外形尺寸:72mm×88mm×66mm外观说明①L N 为220V强电输入②DC24V、DA TA+、DATA-、COM为485总线接线端。
③模块指示灯:模块正常工作时,为稳定的1秒闪烁,当使能了记忆功能时,模块记忆状态,指示灯快闪3秒,模块出厂和检测状态过程中,指示灯保持常亮。
④复位和出厂按键单按该按键超过1秒时,识别为复位操作,执行模块复位功能,长按该按键超过5秒时,识别为出厂功能,模块出厂会清掉所有数据,数据清空后会自动向交换机申请恢复数据和状态,该功能用于一键更换非正常工作的模块,或恢复模块数据主要设置说明该模块接为220V-250V强电输入转换弱电24V输出。
安装连接♦安装条件安装位置要通风良好,注意防潮、防震、防尘。
接线规格本模块电机控制连接线:1.0mm2铜导线。
485总线连接线:工程专业4芯线。
安全使用与维护保养1.使用前详细阅读所有说明。
2.勿靠近干扰设备。
3.要建立良好通风散热环境。
4.在使用过程中,注意防潮、防震、防尘。
5.严禁雨淋、接触其它液体或腐蚀性气体。
6.定期除尘,不能用酒精、汽油等挥发性液体擦拭。
7.如受潮或被液体侵袭,应及时进行干燥处理。
8.定期检查线路的受损和老化程度,应及时更换不合格线路。
9.机器出现故障时,请与专业维修人员或本公司联系。
一、ACT24MD30III直流电力电源充电模块称说明概述
ACT24MD30III直流电力电源充电模块称可在工作电流范围内进行频繁的操作或多次开断短路电流;机械寿命可高达30,000次,满容量短路电流开断次数可达50次。
直流电力电源充电模块适于重合闸操作并有极高的操作可靠性与使用寿命。
直流电力电源充电模块(普通型)采用了立式的绝缘筒防御各种气候的影响;且在维护和保养方面,通常仅需对操作机构做间或性的清扫或润滑。
直流电力电源充电模块(极柱型)采用了固体绝缘结构—集成固封极柱,实现了免维护。
直流电力电源充电模块在开关柜内的安装形式既可以是固定式,也可以是可抽出式的,还可安装于框架上使用
动静触头允许磨损累计厚度mm 3
四、直流电力电源充电模块选型
用户可根据被保护对象选用不同型号的直流电力电源充电模块,对使用场所的不同可选用防污型和高原型。
为满足市场的需求我厂可根据用户的要求设计各种非标产品。
《直流电力电源充电模块ACT24MD30III》
五、直流电力电源充电模块使用条件:
1.适用于户内、外;
2.环境温度-40℃~+40℃;
3.海拔高度不超过3000m(瓷套式不超过1000m);
4.电源频率不小于48Hz、不超过62 Hz;
5.长期施加在直流电力电源充电模块端子间的工频电压不超过直流电力电源充电模块的持续运行电压;
6.地震烈度8度及以下地区;
7.大风速不超过35m/s。
8.直流电力电源充电模块保护发电厂、变电站的交流电气设备免受大气过电压和操作电压的损坏。
直流电
力电源充电模块是变电站被保护设备免遭雷电冲击波袭击的设备。
直流电力电源充电模块测量电流是否超过电动机的额定电流值,调整整定电流值。
电动机运行时过载,热继电器的辅助头,常闭点断开,常开点闭合的特性进行保护。
在继电控制中把常闭点与停止按钮串入,过载时停止电动机运行,并给出报警信号。
六、直流电力电源充电模块基本原理
直流电力电源充电模块是一种过电压(电流)保护器,主要用于保护电力系统、铁道电气化系统、通讯系统中的各种电气设备(变压器、开关、电容器、阻波器、互感器、发电机、电动力、电力电缆等)免遭大气过电压、电流操作过电压(电流)和工频暂态过电压(电流)等损坏,是电力系统绝缘配合的基础。
直流电力电源充电模块的其核心元件采用了以航空标准的先进配方,具有十分优异的非线性(伏一安)特性,即在正常工作电压、电流之下,通过的电流有微安级,当遭受到过电压时,通过的电流瞬间达到数千安培,使避雷器处于导通状态,释放过电压能量,从而有效地限制了过电压对输变电设备的侵害。
传统的直流电力电源充电模块有因放电电压高、操作波放电分散性大导致辞操作波放电电压高等缺点,而扬州福一开关有限公司研发的直流电力电源充电模块具有良好的陡波响应特性,对陡波电压电流无延迟,操作残压低,没有放电分散性等优点,使得陡波、操作波下的保护裕度大大提高,而且在绝缘配合方面,能够作到陡波,雷电波、操作波的保护裕度近接一致,从而对电力设备提供最佳的保护。
直流电力电源充电模块,密封性能良好、防爆性优异,耐污秽免清洗并能减少雾天温闪发生,耐电蚀、抗老化、体积小、重量轻,便于安装和维护。
是20世纪的更新换代产品。
七、直流电力电源充电模块技术标准
产品生产执行的标准为GB11032-2000(eqvIE60099-4.1991)《直流电力电源充电模块》、
JB/8952-20045《直流电力电源充电模块》
八、直流电力电源充电模块产品特点
1、体积小、重量轻、耐碰撞、运输无碰损,安装灵活,适合在开关柜内使用。
2、特殊结构,整体模压成形,无所隙、密封性良好、防潮防爆。
3、爬电距离大,憎水性好,耐污能力强,性能稳定,减少运行维护。
4、独特配方的航空技术标准,泄漏电流小,老化速度慢,使用寿命长。
5、实配直流参考电压、方波通流容量和大电流耐受能力都高于国家标准。
九、用户需知
1、直流电力电源充电模块在安装使用前,应存放在清洁、干燥的房间,不得受到腐蚀性气体或者液体的腐蚀。
2、直流电力电源充电模块在投入运行前,应作预防性试验,在投入运行后,也应定期(10KV以下直流电力电源充电模块5年一次,35KV及以上直流电力电源充电模块2年一次)做如下试验并参照附表与运行前的数据进行对比。
3:测量直流电力电源充电模块的绝缘;
4:测量直流电力电源充电模块的耐压;
十、直流电力电源充电模块出厂报告
直流电力电源充电模块出厂检验报告
检验方式出厂:检验
序号检验名称检验内容检验结果
1 主要配件入厂检验电压,电流,耐压,张力,拉力,合格
2 组装车间7S生产标准人员、机器,坏境合格
3 组装半成品一道检测材料,外观合格
合格4 组装半成品二道检测正常坏境测试(万次比倍测试)
(测试100次出现的损伤,*100是否
达标)
合格5 组装半成品三道检测极限坏境测试(万次比倍测试)
(测试100次出现的损伤,*100是否
达标)
合格6 组装完毕测试装入标准电器组件中(测试多种配套是
否兼容)
7 成品一道检测包装,外观合格
8 出厂检测拍照,扫描合格
经检验各项符合标准规定,准予出厂
检验员:质检公司:扬州福一开关有限公司。