TC7S02F(TE85L,F), 规格书,Datasheet 资料
- 格式:pdf
- 大小:228.06 KB
- 文档页数:7
SPECIFICATION:Electrical Rating……………………………. …. …100~240V AC 50/60HZ Fan Relay Amps inductive…………………….. …8A Heat/Cool Relay Amps inductive………………3AAccuracy …………………………………………±0.5°C (1 °F) Set point Temperature Range……………………..5℃to 60℃Dimensions…………………….. ….. ….. ….. …..120.9mm ×82.9mm ×28mmFEATURES:● New vertical design, crosswise installation or vertical installation ● Temperature adjustments are simple● Display shows both set points and room temperature simultaneously ● Maintains the temperature to within 1 degree set point ● Auto fan with adjustable 3-fan speed.● Permanent user setting retention during power loss, no batteries are required ● External sensor, Remote control ● RS485 communication functionIMPORTANT SAFETY INFORMATION:● Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the offposition before installing, removing, cleaning, or servicing this thermostat. ● Read all of the information in this manual before installing this thermostat. ● Only a professional contractor should install this thermostat.● All wiring must conform to local and national building and electrical codes and ordinances.OPERATIONThermostat Buttons and Switches① Display area② System button (COOL, HEAT)In switch on state, long press this button for 3 seconds, can start or close sleep modeIn switch off state, long press this button for 3 seconds, can enter to menu setting③ Fan speed option button (HI MED LOW AUTO)In switch on state, long press this button for 3 seconds, will enter to switch off timer mode; In switch off state, long press this button for 3 seconds, will enter to switch on timer mode ④ Raises temperature setting ⑤ Lowers temperature settingThe Display①Shows working mode②Shows setting temperature③Shows measure temperature④Shows sleep mode⑤Temperature unit mark⑥Shows fan speed option⑦Shows fan rotate in Auto speed⑧Shows fan speed option⑨Shows heating output⑩Shows cooling output⑪Shows room card modeINSTALL THE THERMOSTATATTACH THERMOSTAT BASE TO WALLWIRING DIAGRAM485 Communication Function InstructionWhen 485 communication distance is more than 300m, need to increase terminal resistance in 485 the beginning of the communication terminal and end. Especially, if communication equipment quantity is less in trunk(less thanCONFIGURATIONThe configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements. Switch off the thermostat , long press button②over 4 seconds, till power on again means you have entered the first configuration menu item. There are 6 menu items. Press button ② to change to the next item and press button ④ or ⑤ to select.In implicit parameter menu mode, long press button ⑥for 3 seconds, all parameter will back to the initial value.1) Adjust temperature coefficient 4 LO to 4 HIYou can adjust the room temperature display up to 3 higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat.2) Select maximum temperature for heatingThis feature provides a maximum setpoint temperature for heat. The default setting is 35℃, It can be changed between 20℃to 50℃.3) Select minimum temperature for coolingThis feature provides a minimum setpoint temperature for cooling. The default setting is 5℃, It can be changed between 5℃ to 20℃.4) Select temperature unit°C or ℉, the factory default is °C5) Display backlight mode option1: The light will keep the light off continuously.2: The display will be on when any button of the thermostat is touched, light off automatically after 10 seconds 3: The display will keep the light on continuouslyThe factory default is 26) Memorize switch on/off option before power lossUsing button ④or ⑤to select “rE” or “rd”. “rd”: The thermostat is switched on or off before power loss, after the power supply comes to normal again the thermostat will keep switch off; “rE”: The thermostat will Memorize its ON or OFF status before power loss. The factory default is “rd”7) Fan stop optionUsing button ④or ⑤to select “ON” or “OFF”. If you select “O N the thermostat will turn on the fan at a speed provided by the Fan Switch and will not stop the fan when there is no call for heat or cool. If you select “OFF”, the thermostat will stop the fan when there is no call for heat or cool.8) Select control systemPress button ④or ⑤to select 4 or 2. 4 means four pipe; 2 means two pipe. The factory default is 4.9) 485 communication addressThe setting range is 1——255, the factory default is 1, press button ④ or ⑤ to select.10) Select energy saving setpoint for heatingThis feature allows you to set energy saving setpoint temperature for heating. The default setting is 18℃, It can be changed between 10℃to 18℃.11) Select energy saving setpoint for coolingThis feature allows you to set energy saving setpoint temperature for cooling. The default setting is 25℃, It can be changed between 25℃to 30℃.12) Activate Window Card function mode optionThis feature allows you to select the way to activate the energy saving mode.Select OC to activate the energy mode by open circuit.Select SC to activate the energy mode by close circuit.Select 00 to cancel the energy mode.Timer switch on/off function and relay delay protection functionIn switch off state, long press button for 3 seconds, will enter into set the automatically switch on time, press button ④or ⑤to set the time, the time value will raise or lower 0.5; In switch on state, long press button for 3 seconds, will enter into set the automatically switch off time, similarly press the raise button or lower button to set the time value.In timer switch on/off mode, the setting value is the countdown value. For example: when you set the time value is 3.5 in switch on state, your thermostat will switch off automatically after three and a half hours. If the time value is 0, means you have closed the timer switch on/off function. In switch on state, if you have open the timer switch off function, the LCD will display the timer mark and the remaining time.The thermostat also have relay delay protection, remote control and 485 communication function.。
DN-7060:B4 • 09/29/2023 — Page 1 of 2NFN-GW-PC-HNW-2NFN-GW-EM-3ONYXWorks ®Gateways - NFN Fire MonitoringGeneralThe NOTI•FIRE•NET™ (NFN) Gateway is an intelligent gateway interface for the ONYXWorks ® fire monitoring workstation. This gateway facilitates complete monitoring and control of a standard or high-speed NFN network and is available in a PC version and an embedded version. In addition, it supports full panel programming and network diagnostics.The PC version of the gateway is the network interface for a true peer-to-peer network and resides in ONYXWorks workstations. The embedded version is a standalone gateway and is equipped with IP capability thus enabling ONYXWorks users to monitor multi -ple sites over an Ethernet network without the need for remote work -stations.Features•Enables ONYXWorks workstation to monitor alarm, prealarm,trouble, and disabled events for NOTIFIER fire alarm control panels on a standard or high-speed NFN network.•Adds acknowledge, silence, reset, enable/disable, and activate/deactivate control capability to the workstation.•Supports fire alarm control panel programming upload/downloads and modifications.•Standalone embedded version for: ability to scale, remote IP connections.•Supervised IP connections for remote workstations and gateways.• Multiple workstations can access the gateway at the same time.•PC versions support standard (wire or multimode fiber options) or high-speed (wire, singlemode or multimode fiber).• Gateway redundancy for network survivability.CompatibilityThe NFN Gateway is compatible with ONYXWorks and ONYX FirstVision ® and interfaces to NFN version 5.0 and higher for the following panels and devices:•ONYX ® Series•N16 NOTIFIER INSPIRE™ Series (PC version NFN Gateways only)•BACnet Gateway•NCA-2/NCA Network Control Annunciator •NCD (PC Version NFN Gateways only)SpecificationsPC VERSION:•Requires an ONYXWorks Workstation (see ONYXWorks data sheet DN-7048)•Operating temperature: 0°C to 49°C (32°F to 120°F)EMBEDDED VERSION:•Input current: 450 mA @ 24 VDC•Input voltage range: 19 VDC to 29 VDC. NFPA Class B or Class A operation•Operating temperature: 0°C to 49°C (32°F to 120°F)•Mounts on a CHS-4L chassis in a CAB-4 Series cabinet (see data sheet DN-6857)•Direct connection to NFS2-640, NFS-640, NFS-320, NFS2-3030,and NFS-3030 fire alarm control panels•The embedded version NFN-GW-EM-3 is not compatible with NOTIFIER INSPIRE series (N16/NCD)•NCM-W or NCM-F required for connection to the NOTI•FIRE•NET (see data sheet DN-6861)HIGH-SPEED NFN CONNECTIVITY:In order to connect to the High-Speed NFN (see data sheet DN-60455), one of the following high-speed network control modules (see data sheet DN-60454) is required:•HS-NCM-W-2 (twisted-pair wire)•HS-NCM-WMF-2 (wire and multimode fiber-optic)•HS-NCM-WSF-2 (wire and singlemode fiber-optic)•HS-NCM-MF (multimode fiber-optic)•HS-NCM-MFSF (multimode and single-mode fiber-optic)•HS-NCM-SF (singlemode fiber-optic)Standards and CodesThe NFN Gateway complies with the following standards: •UL 864, 10th Edition •UL 2017, 2nd Edition •UL 2572, 2nd Edition •UL 2610, 2nd Edition •ULC S527-11•ULC S559-13 •NFPA 72NOTIFIER ®, ONYX ®, ONYXWorks ®, and FirstVision ® are registered trademarks, and NOTIFIER INSPIRE™ and NOTI•FIRE•NET™ aretrademarks of Honeywell International Inc. Microsoft ® and Windows ® are registered trademarks of the Microsoft Corporation. IBM ® is a registered trademark of International Business Machines Corp.©2023 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice.Country of Origin: USANOTIFIER12 Clintonville Road Northford, CT 06472 203.484.7161Agency Listings and ApprovalsThe following listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult Honeywell for the latest listing status.•UL/ULC: S5526 (PC Gateways), S5697 (NFN-GW-EM-3)•CSFM: 7300-1525:103, 7300-0028:0514•FM Approved •FDNY:–COA # 2020-TMCOAP-003337-AMND (NFS2-3030)–COA # 2020-TMCOAP-003349-AMND (NFS-320, NFS2-640)Ordering InformationNFN-GW-EM-3: NOTI•FIRE•NET Gateway, Embedded. Includes PC board, and Surge Suppressor (PNET-1).NFN-GW-PC-W: NOTI•FIRE•NET Gateway PC card for wire media (PCI card).NFN-GW-PC-F: NOTI•FIRE•NET Gateway PC card for multimode fiber media (PCI card).NFN-GW-PC-HNMF: High-Speed NFN Gateway PC card for multi -mode fiber mediaNFN-GW-PC-HNSF: High-Speed NFN Gateway PC card for single mode fiber mediaNFN-GW-PC-HNW-2: High-Speed NFN Gateway PC card for wire mediaADDITIONAL PC VERSION GATEWAY REQUIRED COMPONENTS:•ONYXWorks Workstation (P/N ONYXWORKS-WS)ADDITIONAL EMBEDDED VERSION GATEWAY REQUIRED COMPONENTS:• IBM ®-compatible PC with Microsoft ® Windows ®10。
T-1 (3mm) INFRARED EMITTING DIODE 4. The specifications, characteristics and technical data described in the datasheet are subject to change without prior notice.Selection GuideAbsolute Maximum Ratings at TA=25°CElectrical / Optical Characteristics at TA=25°CPart No.Emitting Color (Material)Lens TypePo (mW/sr) [2] @ 20mA *50mA Viewing Angle [1] Min. Typ. 2θ1/2L-34SF4CInfrared (GaAlAs)Water Clear3 16 *5 *2050°Parameter P/N Symbol Typ. Max. Units Test ConditionsForward Voltage [1] SF4 V F 1.3 1.6 VI F =20mAReverse CurrentSF4I R 10 uA V R = 5VCapacitance SF4 C 90 pF V F =0V;f=1MHz Peak Spectral Wavelength SF4λP 880 nm I F =20mASpectral BandwidthSF4 Δλ1/2 50 nmI F =20mAParameter Symbol Values UnitsPower dissipation P D 80 mWDC Forward Current I F 50 mAPeak Forward Current [1] i FS 1.2A Reverse Voltage V R 5V Operating Temperature T A -40 To +85 °C Storage Temperature T STG-40 To +85°CLead Solder Temperature [2] 260°C For 3 Seconds Lead Solder Temperature [3]260°C For 5 SecondsNotes:1. Forward Voltage: + / -0.1V.2. Wavelength value is traceable to CIE127-2007 standards.3. Excess driving current and / or operating temperature higher than recommended conditions may result in severe light degradation or premature failure.Notes:1. θ1/2 is the angle from optical centerline where the luminous intensity is 1/2 of the optical peak value.2. *Radiant intensity with asterisk is measured at 50mA;Radiant Intensity / luminous flux: +/-15%.3. Radiant intensity value is traceable to CIE127-2007 standards.Notes:1. 1/100 Duty Cycle, 10μs Pulse Width.2. 2mm below package base.3. 5mm below package base.4. Relative humidity levels maintained between 40% and 60% in production area are recommended to avoid the build-up of static electricity – Ref JEDEC/JESD625-A and JEDEC/J-STD-033.Ki ng br i g ht。
非常感谢您购买飞世龙机电有限公司的开关,以下注意事项是有关安全的重要内容。
请在使用本产品之前,一定要全部阅读本说明书的注意事项、附属的安装使用说明以及其他附属内容后再正确使用。
请了解开关的相关知识,注意事项以及安全事项后再使用本开关。
本说明书按照安全注意事项危险程度区分为「危险」,「警告」,「注意」。
安装使用错误时可能会发生死亡或重大灾害的紧急情况。
安装使用错误时可能会引起死亡或重大灾害的隐患。
安装使用错误时可能会引起轻伤或小事故的引患。
◆ 搬运时注意事项◆ 安装(适用、连接)时注意事项 ◆ 操作时注意事项目录1.概要 51.1保管1.2搬运2.额定 53.构造 64.设置 62.定格 32.1“CT” TYPE3.设置 43.1 设置及连接3.2 设置3.3 panel加工尺寸3.5 主电路接头尺寸4.组做74.1 手动组做4.2 自动组做5.保修清点116.定期清点127.其他131.使用关于开关的保管、搬运及设置,请在使用前详细阅读说明书,全面熟知开关的知识、安全信息及注意事项后再进行。
1.1保管开关的安装设置是在到达后即时使用,不得已需要进行一定时间的保管时,请留意下面注意事项。
1.1.1 在高温或潮湿的场所对开关功能会有所降低,要在干燥的场所保管。
1.1.2 要避开有灰尘及会产生有害气体的场所,否则会产生腐蚀开关的现象。
1.1.3 开关要放在平坦的场所保管,不要直接接触地面。
1.2搬运1.2.1 搬运开关时,请确认开关是否在“OPEN”状态。
1.2.2 为了避免开关受到冲击,搬运时请轻拿轻放。
2.额定2.1“CT”TYPE备注1,辅助开关的开关容量是:AC110V 5A,AC220V 2.5A,DC110V 0.5A。
3安装安装时请注意以下事项。
3.1设置3.1.1 CTTS的构造特性设计是以固定方向安装而成,如果安装方向发生变化,它的特性会有变化,所以要正确的安装。
3.1.2 根据配线及开关配置现状,在不能正常安装的情况下,请与本公司联系和商谈。
USB2.0 HUB控制器集成电路USB 2.0 HIGH SPEED 4-PORT HUB CONTROLLERSL2.2s数据手册Data Sheet内容目录第一章管脚分配 (3)1.1 SL2.2S管脚图 (3)1.2 SL2.2S管脚定义 (3)第二章 功能叙述 (5)2.1综述 (5)2.2指示灯 (5)2.2.1单灯方案 (5)2.2.2多灯方案 (6)2.2.3 LED指示定义 (6)2.3过流保护 (6)2.4充电支持 (6)2.5I2C接口 (7)2.6EEPROM设置 (7)第三章电气特性 (8)3.1极限工作条件 (8)3.2工作范围 (8)3.3直流电特性 (8)3.4HS/FS/LS电气特性 (8)3.5ESD特性 (8)附录一封装 (9)表格目录表格1: 端口LED定义 (6)表格 2 : ACTIVE LED定义 (6)表格3:EEPROM数据结构定义 (7)表格4: 最大额定值 (8)表格5: 工作范围 (8)表格6: 直流电特性 (8)插图目录图1:SSOP28 管脚图 (3)图2:单灯方案配置 (5)图3: 5灯方案配置 ............................................................................... (6)图 4:附录 封装图 ................................................................................... .9第一章管脚分配1.1SL2.2s管脚图图1:SSOP28 管脚图1.2SL2.2s管脚定义管脚名称28Die IO类型定义Pin#VSS 1 P 芯片地XOUT 2 O晶振PAD XIN 3 IDM4 4 B下行口4的USB信号DP4 5 BDM3 6 B下行口3的USB信号DP3 7 BDM2 8 B下行口2的USB信号DP2 9 BDM1 10 B下行口1的USB信号DP1 11 BVDD18 12 P 模拟1.8vVDD33 13 P 模拟3.3v - 14 NCUDM 15 B上行口的USB信号UDP 16 BRESET_N 17 I,Pu 芯片外部复位输入- 18 NCPSELF 19 I,Pu 高为自供电,低为总线供电VDD5 20 P 5v输入VDD33 21 P 3.3v输出DRV 22 B,Pu 点灯驱动信号LED1 23 B,Pu 点灯驱动信号LED2 24 B,Pu 点灯驱动信号PWRN 25 B,Pu 下行口电源输出控制,低有效OVCRN/SDA 26 B,PuI2C SDA数据线,内部上拉;芯片初始化完成后作为过流保护输入脚,低有效SCL 27 B,Pu I2C SCL时钟输出VDD18 28 P 数字1.8v注释:O,输出;I 输入;B 双向;P 电源/接地;Pu 上拉;Pd 下拉;NC 悬空;第二章 功能叙述2.1综述SL2.2s 是一颗高集成度,高性能,低功耗的USB2.0集线器主控芯片;该芯片采用STT 技术,单电源供电方式,芯片供电电压为5v , 内部集成5V 转3.3V,只需在外部电源添加滤波电容;芯片自带复位电路,低功耗技术让他更加出众。
ULTRA COOL PRODUCTS889 BARTON ST. UNIT #1STONEY CREEK, ON L8E 5V1905-643-0060PRODUCT: Ultra Flame Propane Canister 8ozCODE: UF-4949SECTION 01: IDENTIFICATIONProduct Identifier.......................................Ultra Flame Propane Canister 8ozOther means of Identification....................UF-4949Chemical Family........................................Propane.Recommended use and restrictions..........Soldering, braising.Initial Supplier Identifier.............................Ultra Cool Products889 Barton St. Unit #1Stoney Creek, ON L8E 5V1Tel: 905-643-0060Fax: 905-828-8070Email: info@ultracooEmergency telephone number and any ...Ultra Cool Products: 905-643-0060 (9:00 - 5:00; M-F) . In the event of a transportrestrictions on the use of that number emergency contact CANUTEC at (613) 996-6666. .SECTION 02: HAZARD IDENTIFICATIONSignal Word...............................................DANGER.Hazard Classification................................. Flammable Gases — Category 1. Gases Under Pressure — Liquefied Gas. FlammableLiquid - Category 2. Skin Sensitizer — Category 1. Skin Irritation — Category 2.Hazard Statements....................................H220 Extremely flammable gas . H225 Highly flammable liquid and vapour. H280 Containsgas under pressure; may explode if heated . H315 Causes skin irritation. H317 May causean allergic skin reaction. Prevention.................................................P210 Keep away from all sources of heat, sparks, open flames, hot surfaces. No smoking.P233 Keep container tightly closed. P240 Ground and bond container and receivingequipment. P241 Use explosion-proof equipment . P242 Use only non-sparking tools. P243Take precautionary measures against static discharge. P261 Avoid breathing dust, vapor,mist or spray. P264 Wash thoroughly after handling. P272 Contaminated work clothingshould not be allowed out of the workplace. P280 Wear protective gloves/protectiveclothing/eye protection/face protection. Response..................................................P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely . P381 In caseof leakage, eliminate all ignition sources . P303+P361+P353 IF ON SKIN (or hair)immediately take off all contaminated clothing, rinse skin with water or use emergencyshower. P370+P378 In case of fire - use dry chemical powder, CO2 or foam to extinguish.P302+P352 IF ON SKIN: Wash with plenty of water. P333+P313 If skin irritation or rashoccurs: Get medical attention. P362+P364 Take off contaminated clothing and wash beforereuse. Storage......................................................P403+P235 Store in well ventilated place. Keep cool. P410 + P403 Protect from sunlight.Store in a well-ventilated place . Disposal.....................................................P501 Dispose of contents and empty containers in accordance with local regulations.Other hazards............................................H400 Very toxic to aquatic life . H410 Very toxic to aquatic life with long lasting effects.Avoid release to the environment. Collect spillage.Mixture Statement.....................................This product has been classified based upon the information provided by the supplier.SECTION 03: COMPOSITION / INFORMATION ON INGREDIENTSCHEMICAL NAME AND SYNONYMS CAS #WT. %Petroleum gases, liquefied 68476-85-799.7Ethyl Mercaptin75-08-10.28Cyclohexene, 1-methyl-4-(1-methylethenyl)- 138-86-30.02SECTION 04: FIRST-AID MEASURESFIRST AID MEASURES:Skin Contact.............................................Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes.To avoid the risk of static discharges and gas ignition, soak contaminated clothingthoroughly with water before removing it. Get medical attention if symptoms occur. In caseof contact with liquid, warm frozen tissues slowly with lukewarm water and get medicalattention. Do not rub affected area. Wash clothing before reuse. Clean shoes thoroughlybefore reuse.Eye Contact..............................................Check for an remove any contact lenses. Immediately flush eyes with plenty of water for atleast 15 minutes, occasionally lifting the upper and lower eyelids. . Get medical attentionimmediately.Ingestion...................................................Remove victim to fresh air and keep at rest in a position comfortable for breathing. Getmedical attention if adverse health effects persist or are severe. Ingestion of liquid cancause burns similar to frostbite. If frostbite occurs, get medical attention. Never giveanything by mouth to an unconscious person. . If unconscious, place in recovery positionand get medical attention immediately. Maintain an open airway. Loosen tight clothing suchas a collar, tie, belt or waistband. As this product rapidly becomes a gas when released,refer to the inhalation section.Inhalation..................................................If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing isdifficult, give oxygen. Get medical attention. It may be dangerous to the person providingair to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and getmedical attention immediately. Maintain an open airway. Loosen tight clothing such as acollar, tie, belt or waistband.Symptoms and effects...............................May cause an allergic skin reaction. Liquid can cause burns similar to frostbite. Dermalcontact with rapidly evaporating liquid could result in freezing of the tissues or frostbite.Harmful if inhaled. Asphyxiant gas.Medical attention and special treatment....Adverse symptoms may include frostbite. Treat symptomatically. In the event of an incidentinvolving this product ensure that medical authorities are provided a copy of this safetydata sheet.SECTION 05: FIRE-FIGHTING MEASURESSuitable and unsuitable extinguishing e an extinguishing agent suitable for the surrounding fire.mediaSpecific hazards arising from the .............Contains gas under pressure. Extremely flammable gas. In a fire or if heated, a pressure hazardous product, such as the nature of increase will occur and the container may burst, with the risk of a subsequent explosion. any hazardous combustion products The vapor/gas is heavier than air and will spread along the ground. Gas may accumulate inlow or confined areas or travel a considerable distance to a source of ignition and flashback, causing fire or explosion. By fire: Protect against potentially toxic and irritating fumes. Special protective equipment and ............Promptly isolate the scene by removing all persons from the vicinity of the incident if there precautions for fire-fighters is a fire. No action shall be taken involving any personal risk or without suitable training.Move containers from fire area if this can be done without risk. Use water spray to keepfire-exposed containers cool. Cool fire-exposed containers with cold water spray. Heat willcause pressure build up and may cause explosive rupture . Eliminate all ignition sources ifsafe to do so. Use self-contained breathing apparatus and full firefighting gear.Decomposition and combustion products may be toxic. Fire-fighters should wearappropriate protective equipment and self-contained breathing apparatus (SCBA) with a fullface-piece operated in positive pressure mode. Contact supplier immediately for specialistadvice.SECTION 06: ACCIDENTAL RELEASE MEASURESPersonal precautions, protective .............No action shall be taken involving any personal risk or without suitable training. Evacuate equipment and emergency procedures surrounding areas. Keep unnecessary and unprotected personnel from entering. Do nottouch or walk through spilled material. Avoid breathing vapor or mist. Provide adequateventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriatepersonal protective equipment (see section 8). No flares, smoking or flames in hazardarea. Avoid dispersal of spilled material and runoff the contact with soil, waterways, drainsand sewers. Ensure emergency procedures to deal with accidental gas releases are inplace to avoid contamination of the environment.Methods and materials for containment ..Immediately contact emergency personnel. Stop leak if without risk. Use spark-proof tools and cleaning up and explosion-proof equipment. Ventilate area. Prevent product from entering sewers orwaterways.SECTION 07: HANDLING AND STORAGEPrecautions for safe handling....................Exposure to this product requires prior training and information. Read the information onthe label and the safety data sheet before handling this product. Contains gas underpressure. Put on appropriate personal protective equipment. Wear appropriate respiratorSECTION 07: HANDLING AND STORAGEPrecautions for safe handling....................when ventilation is inadequate. Avoid contact with skin and eyes. Do not swallow. Do notbreathe gas/fumes/vapor/spray. Use only in well-ventilated areas. Handle and opencontainer with care. Launder contaminated clothing before reuse. When using, do not eator drink. Wash hands before eating, drinking, or smoking. Do not enter storage areas andconfined spaces unless adequately ventilated. Store and use away from heat, sparks, openflame or any other ignition source. Use explosion-proof electrical (ventilating, lighting andmaterial handling) equipment. Use only non-sparking tools. Take precautionary measuresagainst electrostatic discharges. Empty containers retain product residue and can behazardous. Do not reuse container. Close valve after each use and when empty. Protectcylinders from physical damage; do not drag, roll, slide or drop.Conditions for safe storage, including any Store in accordance with local regulations. Store in a segregated and approved area. Store incompatibilities away from all sources of heat and ignition. Store away from direct sunlight. Store awayfrom incompatible materials . Keep container tightly closed in a well ventilated area.SECTION 08: EXPOSURE CONTROLS / PERSONAL PROTECTIONACGIH TLV OSHA PEL NIOSH INGREDIENTS TWA STEL PEL STEL RELPetroleum gases, 1000 ppm Not established1800 mg/m³ (1000 Not established1800 mg/m³ (1000 liquefied ppm)ppm)Ethyl Mercaptin0.5 ppm0.5 ppm10 ppm (25 mg/m3) 0.5 ppm (1.3ceiling mg/m3L) ceiling Cyclohexene, 30 ppm (WEEL)Not established Not established Not established Not established1-methyl-4-(1-methylethenyl)-Appropriate engineering e local exhaust ventilation to maintain airborne concentrations below the TLV. Suitablerespiratory equipment should be used in cases of insufficient ventilation or whereoperational procedures demand it. For guidance on engineering control measures refer topublications such as the ACGIH current edition of 'Industrial Ventilation, a manual ofRecommended Practice. The engineering controls also need to keep gas, vapor or dustconcentrations below any lower explosive limits. Use explosion -proof ventilationequipment.Individual protection measures, such aspersonal protective equipmentEye/Type..................................................Face shield and safety glasses Use equipment for eye protection tested and approvedunder appropriate government standards such as NIOSH (US) or EN 166(EU).Gloves/Type.............................................Wear skin protection equipment. The selection of skin protection equipment depends onthe nature of the work to be performed. Wear chemical resistant gloves to prevent skincontact. Contact glove supplier for additional information.Footwear/Type.........................................Wear safety boots per local regulations.Clothing/Type ..........................................Wear adequate protective clothing to prevent skin contact.Respiratory/Type......................................Where risk assessment shows air-purifying respirators are appropriate use a full-facerespirator with multi- purpose combination (US) or type ABEK (EN 14387) respiratorcartridges as a backup to engineering controls.Other/Type...............................................Handle in accordance with good industrial hygiene and safety practice. Take offimmediately all contaminated clothing. Wash contaminated clothing before reuse.Emergency eye wash station and shower should be available. Anyone handling thisproduct should wash their hands and face before eating, drinking or using tobaccoproducts.SECTION 09: PHYSICAL AND CHEMICAL PROPERTIESAppearance / physical state .....................Gas, compressed. Colour........................................................Colorless. Odour........................................................Odour added. Sulphur like.Odour Threshold (ppm).............................Not available. pH..............................................................Not applicable.Melting/Freezing Point...............................-166.11°C (-267°F) .Initial Boiling Point/Boiling Range..............-34.66°C (-30.4°F) .Flash Point (deg C), Method.....................-60°C (-76°F).Evaporation Rate.......................................Rapid.Flammability (solid/gas).............................Extremely flammable gas.Upper Flammable Limit (% Vol)................8.5.Lower Flammable Limit (% Vol)................ 1.9.Vapour Pressure (mm Hg)........................70 @ 70°F.Vapour Density (Air=1).............................. 1.76.Relative Density/Specific Gravity..............0.54. Solubility....................................................Not available.SECTION 09: PHYSICAL AND CHEMICAL PROPERTIESCoefficient of Water/Oil Distribution..........Not available.Auto Ignition Temperature (deg C)............862.77°C (1585°F).Decomposition temperature......................Not available. Viscosity....................................................Not applicable.SECTION 10: STABILITY AND REACTIVITYReactivity...................................................Contains gas under pressure; may explode if heated. Reacts with oxidants causing fire andexplosion hazard.Chemical stability......................................Stable at normal temperatures and pressures.Possibility of hazardous reactions.............Will not polymerize.Conditions to avoid, including static .........Avoid all sources of ignition: heat, sparks, open flame. Avoid sunlight. Avoid extreme discharge, shock or vibration temperatures.Incompatible materials..............................Strong oxidizing agents.Hazardous decomposition products..........No hazardous decomposition products if stored and handled as prescribed/indicated.SECTION 11: TOXICOLOGICAL INFORMATIONINGREDIENTS LC50LD50Petroleum gases, liquefied 658 mg/L (4 hr.)Not determinedEthyl Mercaptin4420 ppm (4 hr.)682 mg/kg (oral, rat) Cyclohexene, 1-methyl-4-(1-methylethenyl)- Not determined5300 mg/kg (oral, rat)Route of Exposure.....................................Skin contact, eye contact, inhalation. ATEs..........................................................Not determined.Symptoms related to the physical,chemical and toxicological characteristicsEffects of Acute Exposure.........................Harmful if inhaled. Causes skin, eye and respiratory irritation . Exposure may causerespiratory and / or skin sensitization. Skin contact may cause severe irritation. Liquid cancause burns similar to frostbite. Harmful if absorbed through the skin .Effects of Chronic Exposure......................Intentional misuse by deliberately concentrating and inhaling this product may be harmfulor fatal. Sensitization..............................................May cause an allergic skin reaction. May cause allergy or asthma symptoms or breathingdifficulties if inhaled. Mutagenicity..............................................No known mutagenicity effects.Reproductive Effects.................................No known reproductive effects. .Carcinogenicity of Material........................None of the components present in this material at concentrations equal to or greater than0.1% are listed by IARC, NTP, OSHA OR ACGIH as a carcinogen.Specific Target Organ Toxicity - single .....This information, if applicable, can be found in Section 2.exposureSpecific Target Organ Toxicity - repeated This information, if applicable, can be found in Section 2.exposureSECTION 12: ECOLOGICAL INFORMATIONEcotoxicity.................................................H400: Very toxic to aquatic life. H410 Very toxic to aquatic life with long lasting effects .Discharge into the environment must be avoided.Persistence and degradability...................Product data not available.Bioaccumulation Potential.........................Product data not available.Mobility in soil............................................Product data not available.Other adverse effects................................Product data not available.SECTION 13: DISPOSAL CONSIDERATIONSInformation on safe handling for disposal .Dispose of waste in accordance with all applicable Federal, Provincial/State and localand methods of disposal, including any regulations.contaminated packagingSECTION 14: TRANSPORT INFORMATIONTDG Classification.....................................UN1075 - PETROLEUM GASES, LIQUEFIED, 2.1. Limited Quantity: 0.125 L .Refer to Part 1 of Transportation of Dangerous Goods Regulations for additionalinformation.Transport in bulk / IBC Code.....................No data available.SECTION 15: REGULATORY INFORMATIONCEPA Status.............................................Not reviewed.TSCA Inventory Status..............................All components are listed on TSCA .SECTION 16: OTHER INFORMATIONPrepared by ..............................................Trivalent Data Systems Ltd. . Information based on suppliersSDS. rmation for this material safety data sheet was obtained from sources consideredtechnically accurate and reliable. While every effort has been made to ensure fulldisclosure of product hazards, in some cases data is not available and is so stated. Nowarranty, expressed or implied, is made and supplier will not be liable for any losses,injuries for consequential damages, which may result from the use or reliance on anyinformation contained in this form. .Date of the latest revision of the safety ...2019-09-23data sheet。
®TinyLogic UHS Two-Input AND GateFeaturesUltra-High Speed: t PD 2.7ns (Typical) into 50pF at 5V V CCHigh Output Drive: ±24mA at 3V V CCBroad V CC Operating Range: 1.65V to 5.5VMatches Performance of LCX Operated at 3.3V V CC Power Down High Impedance Inputs/OutputsOver-Voltage Tolerance inputs facilitate 5V to 3V TranslationProprietary Noise/EMI Reduction CircuitryUltra-Small MicroPak™ PackagesSpace-Saving SOT23 and SC70 Packages DescriptionThe NC7SZ08 is a single two-input AND gate from Fairchild’s Ultra-High Speed (UHS) series of TinyLogic®. The device is fabricated with advanced CMOS technology to achieve ultra-high speed with high output drive while maintaining low static power dissipation over a broad V CC operating range. The devise is specified to operate over the 1.65V to 5.5V V CC operating range. The inputs and output are high impedance when V CC is 0V. Inputs tolerate voltages up to 6V, independent of V CC operating voltage.Ordering InformationPart Number Top Mark Eco Status Package Packing MethodNC7SZ08M5X 7Z08 RoHS 5-Lead SOT23, JEDEC MO-178 1.6mm 3000 Units on Tape & ReelNC7SZ08P5X Z08 RoHS 5-Lead SC70, EIAJ SC-88a, 1.25mm Wide 3000 Units on Tape & ReelNC7SZ08L6X GG RoHS 6-Lead MicroPak™, 1.00mm Wide 5000 Units on Tape & ReelNC7SZ08FHX GG Green 6-Lead,MicroPak2, 1x1mm Body, .35mm Pitch 5000 Units on Tape & ReelFor Fairchild’s definition of Eco Status, please visit: /company/green/rohs_green.html.NC7SZ08 — TinyLogic ® UHS Two-Input AND GateFigure 1. Logic SymbolPin ConfigurationsFigure 2. SC70 and SOT23 (Top View)Figure 3. MicroPak (Top Through View)Pin DefinitionsPin # SC70 / SOT23Pin # MicroPakNameDescription1 1 A Input2 2 B Input3 3 GND Ground4 4 Y Output56 V CC Supply Voltage5 NC No ConnectFunction TableY=ABInputs OutputNC7SZ08 — TinyLogic ® UHS Two-Input AND GateSymbol Parameter Min. Max. UnitV CC Supply Voltage -0.5 6.0 V V IN DC Input Voltage -0.5 6.0 V V OUT DC Output Voltage -0.56.0 V V IN < -0.5V -50 I IK DC Input Diode Current V IN > 6.0V +20 mAV OUT < -0.5V-50I OK DC Output Diode Current V OUT > 6V, V CC =GND+20 mAI OUT DC Output Current±50 mA I CC or I GND DC V CC or Ground Current±50 mA T STG Storage Temperature Range -65 +150 °C T J Junction Temperature Under Bias+150 °C T LJunction Lead Temperature (Soldering, 10 Seconds)+260°CSOT-23 200SC70-5 150MicroPak-6 130 P DPower Dissipation at +85°CMicroPak2-6 120mWHuman Body Model, JESD22-A114 4000 ESD Charged Device Model, JESD22-C1012000VRecommended Operating ConditionsThe Recommended Operating Conditions table defines the conditions for actual device operation. Recommendedoperating conditions are specified to ensure optimal performance to the datasheet specifications. Fairchild does not recommend exceeding them or designing to Absolute Maximum Ratings.Symbol ParameterConditions Min. Max. UnitSupply Voltage Operating 1.65 5.50 V CCSupply Voltage Data Retention1.50 5.50 V V IN Input Voltage 0 5.5VV OUT Output Voltage0 V CC V T A Operating Temperature-40 +85 °C V CC at 1.8V, 2.5V ± 0.2V 0 20® UHS Two-Input AND Gate1.65 1.55 1.65 1.55 1.80 1.70 1.80 1.702.30 2.20 2.30 2.203.00 2.90 3.00 2.904.50V IN =V IH , I OH =-100µA 4.40 4.504.401.65 I OH =-4mA 1.29 1.52 1.292.30 I OH =-8mA 1.90 2.15 1.903.00 I OH =-16mA 2.50 2.80 2.40 3.00 I OH =-24mA 2.40 2.68 2.30VV OHHIGH LevelOutput Voltage4.50 I OH =-32mA 3.90 4.20 3.801.65 0.00 0.10 0.10 1.80 0.00 0.10 0.102.30 0.00 0.10 0.103.00 0.00 0.10 0.104.50V IN =V IL , I OL =100µA 0.00 0.10 0.10 1.65 I OL =4mA 0.80 0.24 0.24 2.30 I OL =8mA 0.10 0.30 0.30 3.00 I OL =16mA 0.15 0.40 0.40 3.00 I OL =24mA 0.22 0.55 0.55 VV OLLOW LevelOutput Voltage4.50 I OL =32mA0.22 0.55 0.55 I IN Input LeakageCurrent0 to 5.5V IN =5.5V, GND±1±10µAI OFF Power OffLeakage Current0 V IN or V OUT =5.5V 1 10 µAI CCQuiescent SupplyCurrent1.65 to 5.50 V IN =5.5V, GND220µA® UHS Two-Input AND Gate5.00 ± 0.500.5 2.2 4.1 0.5 4.4 3.30 ± 0.30 1.53.3 5.2 1.5 5.55.00 ± 0.50 C L =50pF,R L =500Ω0.8 2.7 4.5 0.84.8C IN Input Capacitance 0.00 4 pF 3.30 20 C PDPower DissipationCapacitance (2)5.0025pF Figure 6Note:2. C PD is defined as the value of the internal equivalent capacitance which is derived from dynamic operatingcurrent consumption (I CCD ) at no output lading and operating at 50% duty cycle. C PD is related to I CCD dynamic operating current by the expression: I CCD =(C PD )(V CC )(f IN )+(I CC static).Notes:3. C L includes load and stray capacitance.4. Input PRR=1.0MHz; t W 500ns.Figure 4. AC Test CircuitFigure 5. AC Waveforms=1.8ns; PRR=10MHz; Duty Cycle=50%.Test Circuit® UHS Two-Input AND Gate132LAND PATTERN RECOMMENDATIONC 0.10C0.20C A B0.60 REF0.550.35SEATING PLANE0.25GAGE PLANE8°0°NOTES: UNLESS OTHEWISE SPECIFIEDA) THIS PACKAGE CONFORMS TO JEDEC MO-178, ISSUE B, VARIATION AA,B) ALL DIMENSIONS ARE IN MILLIMETERS. 1.45 MAX1.300.900.150.051.900.950.500.301.502.600.701.00SEE DETAIL A0.220.08C) MA05Brev5TOP VIEW (0.30)Figure 7. 5-Lead SOT23, JEDEC MO-178 1.6mmPackage drawings are provided as a service to customers considering Fairchild components. Drawings may change in any manner without notice. Please note the revision and/or date on the drawing and contact a Fairchild Semiconductor representative to verify or obtain the most recent revision. Package specifications do not expand the terms of Fairchild’s worldwide terms and conditions, specifically the warranty therein, which covers Fairchild products.Always visit Fairchild Semiconductor’s online packaging area for the most recent package drawings: /packaging/.Tape and Reel Specifications®UHS Two-Input AND GateFigure 8. 5-Lead, SC70, EIAJ SC-88a, 1.25mm WidePackage drawings are provided as a service to customers considering Fairchild components. Drawings may change in any mannerwithout notice. Please note the revision and/or date on the drawing and contact a Fairchild Semiconductor representative to verifyor obtain the most recent revision. Package specifications do not expand the terms of Fairchild’s worldwide terms and conditions, specificallythe warranty therein, which covers Fairchild products.Always visit Fairchild Semiconductor’s online packaging area for the most recent package drawings:/packaging/.Tape and Reel Specifications® UHS Two-Input AND Gate2. DIMENSIONS ARE IN MILLIMETERS1. CONFORMS TO JEDEC STANDARD M0-252 VARIATION UAAD MAC06AREVCNotes:3. DRAWING CONFORMS TO ASME Y14.5M-1994TOP VIEWRECOMMENED LAND PATTERNBOTTOM VIEWA0.55MAX0.05C(0.75)(0.52)(0.30)6X 1X6X PIN 1DETAIL A0.075 X 45CHAMFER0.250.150.350.250.400.300.5(0.05) 1.0DETAIL APIN 1 TERMINAL0.400.300.450.350.100.000.10C B A 0.05CC0.05C0.050.005X 5X 6X(0.13)4X6XFigure 9. 6-Lead, MicroPak™, 1.0mm WidePackage drawings are provided as a service to customers considering Fairchild components. Drawings may change in any manner without notice. Please note the revision and/or date on the drawing and contact a Fairchild Semiconductor representative to verify or obtain the most recent revision. Package specifications do not expand the terms of Fairchild’s worldwide terms and conditions, specifically the warranty therein, which covers Fairchild products.Always visit Fairchild Semiconductor’s online packaging area for the most recent package drawings: /packaging/.®UHS Two-Input AND Gate DETAIL A5XFigure 10. 6-Lead, MicroPak2, 1x1mm Body, .35mm PitchPackage drawings are provided as a service to customers considering Fairchild components. Drawings may change in any mannerwithout notice. Please note the revision and/or date on the drawing and contact a Fairchild Semiconductor representative to verifyor obtain the most recent revision. Package specifications do not expand the terms of Fairchild’s worldwide terms and conditions, specificallythe warranty therein, which covers Fairchild products.Always visit Fairchild Semiconductor’s online packaging area for the most recent package drawings:/packaging/.NC7SZ08 — TinyLogic ® UHS Two-Input AND Gate。
C O NF ID EN T IA LNSi8120/NSi8121/NSi8122: High ReliabilityDual-Channel Digital IsolatorsDatasheet (EN) 1.8Product OverviewThe NSi812x devices are high reliability dual-channel digital isolator. The NSi812x device is safety certified by UL1577 support several insulation withstand voltages (3.75kV rms , 5kV rms ), while providing high electromagnetic immunity and low emissions at low power consumption. The data rate of the NSi812x is up to 150Mbps, and the common-mode transient immunity (CMTI) is up to 150kV/us. The NSi812x device provides digital channel direction configuration and the default output level configuration when the input power is lost. Wide supply voltage of the NSi812x device support to connect with most digital interface directly, easy to do the level shift. High system level EMC performance enhance reliability and stability of use. AEC-Q100 (Grade 1) option is provided for all devices.Key Features• Up to 5000V rms Insulation voltage• Date rate: DC to 150Mbps• Power supply voltage: 2.5V to 5.5V • All devices are AEC-Q100 qualified • High CMTI: 150kV/us • Chip level ESD: HBM: ±6kV• High system level EMC performance:Enhanced system level ESD, EFT, Surge immunity• Default output high level or low level option • Isolation barrier life: >60 years• Low power consumption: 1.5mA/ch (1 Mbps) • Low propagation delay: <15ns • Operation temperature: -40℃~125℃ • RoHS-compliant packages:SOIC-8 narrow body SOIC-16 wide bodySafety Regulatory Approvals• UL recognition: up to 5000V rms for 1 minute per UL1577• CQC certification per GB4943.1-2011• CSA component notice 5A • DIN VDE V 0884-11:2017-01Applications• Industrial automation system • Isolated SPI, RS232, RS485• General-purpose multichannel isolation • Motor controlFunctional Block DiagramsC O NF ID EN T IA LIndex1.0 ABSOLUTE MAXIMUM RATINGS .............................................................................................................................. 3 2.0 SPECIFICATIONS ........................................................................................................................................................... 3 2.1. E LECTRICAL CHARACTERISTICS .................................................................................................................................................. 3 2.2. TYPICAL PERFORMANCE CHARACTERISTICS ........................................................................................................................... 7 2.3. P ARAMETER M EASUREMENT I NFORMATION . (8)3.0 HIGH VOLTAGE FEATURE DESCRIPTION (9)3.1. INSULATION AND SAFETY RELATED SPECIFICATIONS (9)3.2. DIN VDE V 0884-11(VDE V 0884-11):2017-01 INSULATION CHARATERISTICS ....................................................................... 9 3.3. R EGULATORY INFORMATION ................................................................................................................................................... 11 4.0 FUNCTION DESCRIPTION ..........................................................................................................................................11 5.0 APPLICATION NOTE ................................................................................................................................................... 12 5.1. PCB L AYOUT ...................................................................................................................................................................... 12 5.2. H IGH SPEED PERFORMANCE ................................................................................................................................................... 12 5.3. T YPICAL S UPPLY C URRENT E QUATIONS ..................................................................................................................................... 13 6.0 PACKAGE INFORMATION ......................................................................................................................................... 13 7.0 TAPE AND REEL INFORMATION ............................................................................................................................. 17 8.0 ORDER INFORMATION .............................................................................................................................................. 20 9.0 REVISION HISTORY . (21)C O NF ID EN T IA L1.0 ABSOLUTE MAXIMUM RATINGSPower Supply Voltage VDD1, VDD2 -0.5 6.5 V Maximum Input Voltage VINA, VINB -0.4 VDD+0.41 V Maximum Output Voltage V OUTA , V OUTB -0.4 VDD+0.41 VMaximum Input/Output Pulse VoltageVINA, VINB, V OUTA , V OUTB-0.8VDD+0.8VPulse width should be less than 100ns, and the duty cycle should be less than 10%Common-Mode Transients CMTI ±150 kV/us Output currentIo -15 15mAMaximum Surge Isolation VoltageV IOSM5.3kVOperating Temperature Topr -40125 ℃Storage Temperature Tstg -40150℃Electrostatic dischargeHBM±6000VCDM±2000V1 The maximum voltage must not exceed 6.5V.2.0 SPECIFICATIONS2.1. ELECTRICAL CHARACTERISTICS(VDD1=2.5V~5.5V, VDD2=2.5V~5.5V, Ta=-40℃ to 125℃. Unless otherwise noted, Typical values are at VDD1 = 5V, VDD2 = 5V, Ta =25℃)Power on ResetVDD POR2.2 V POR threshold as during power-upVDD HYS 0.1 V POR threshold Hysteresis Input ThresholdV IT1.6 V Input Threshold at rising edge V IT_HYS 0.4 V Input Threshold Hysteresis High Level Input Voltage V IH 2 V Low Level Input Voltage V IL 0.8 V High Level Output Voltage V OH VDD-0.3 V I OH ≤ 4mA Low Level Output VoltageV OL0.3VI OL ≤ 4mAC O NF ID EN T IA LOutput Impedance R out 50 ohm Input Pull high or low CurrentI pull 8 15 uA Start Up Time after POR trbs 40 usec Common Mode Transient ImmunityCMTI±100±150kV/us(VDD1=5V± 10%, VDD2=5V± 10%, Ta=-40℃ to 125℃. Unless otherwise noted, Typical values are at VDD1 = 5V, VDD2 = 5V, Ta = 25℃)Supply currentNSi8120 I DD1(Q0) 0.58 0.87 mAAll Input 0V for NSi8120x0 Or All Input at supply for NSi8120x1 I DD2(Q0) 1.18 1.77 mA I DD1(Q1) 2.92 4.38 mA All Input at supply for NSi8120x0 Or All Input 0V for NSi8120x1I DD2(Q1) 1.241.86mAI DD1(1M) 1.71 2.56 mA All Input with 1Mbps, C L =15pFI DD2(1M)1.382.07mAI DD1(10M) 1.78 2.67 mA All Input with 10Mbps, C L =15pF I DD2(10M)3.24.8mA I DD1(100M)2.103.15 mA All Input with 100Mbps, C L =15pFI DD2(100M)21.031.5mANSi8121/ NSi8122 I DD1(Q0) 1.031.55 mA All Input 0V for NSi812xx0 Or All Input at supply for NSi812xx1 I DD2(Q0) 1.00 1.5 mA I DD1(Q1)2.203.3 mA All Input at supply for NSi812xx0Or All Input 0V for NSi812xx1 I DD2(Q1)2.133.2 mA I DD1(1M) 1.72 2.58 mA All Input with 1Mbps, C L =15pFI DD2(1M) 1.68 2.52 mA I DD1(10M) 2.62 3.93 mA All Input with 10Mbps, C L =15pFI DD2(10M) 2.71 4.06 mA I DD1(100M) 11.01 16.5 mA All Input with 100Mbps, C L = 15pF I DD2(100M)12.8 19.2 mA Data RateDR 0 150 MbpsC O NF ID EN T IA LPropagation Delayt PLH 5 8.20 15 ns See Figure 2.7 , C L = 15pF t PHL 5 10.56 15 ns See Figure 2.7, C L = 15pF Pulse Width Distortion |t PHL – t PLH | PWD5.0nsSee Figure 2.7 , C L = 15pFRising Time t r 5.0 ns See Figure 2.7 , C L = 15pF Falling Timet f 5.0 ns See Figure 2.7 , C L = 15pFPeak Eye Diagram Jitter t JIT (PK) 350 ps Channel-to-Channel Delay Skewt SK (c2c) 2.5 nsPart-to-Part Delay Skewt SK (p2p)5.0ns(VDD1=3.3V± 10%, VDD2=3.3V± 10%, Ta=-40℃ to 125℃. Unless otherwise noted, Typical values are at VDD1 = 3.3V, VDD2 = 3.3V, Ta =25℃)Supply currentNSi8120 I DD1(Q0) 0.550.83mA All Input 0V for NSi8120x0 Or All Input at supply for NSi8120x1 I DD2(Q0) 1.12 1.68 mA I DD1(Q1) 2.87 4.3 mA All Input at supply for NSi8120x0 Or All Input 0V for NSi8120x1 I DD2(Q1)1.18 1.77mA I DD1(1M)1.72.55mA All Input with 1Mbps, C L = 15pFI DD2(1M)1.271.91 mA I DD1(10M) 1.732.6 mA All Input with 10Mbps, C L = 15pF I DD2(10M)2.413.6 mA I DD1(100M) 2.05 3.08 mA All Input with 100Mbps, C L = 15pF I DD2(100M)14.0521.08mANSi8121/ NSi8122 I DD1(Q0) 0.98 1.47 mA All Input 0V for NSi812xx0 Or All Input at supply for NSi812xx1 I DD2(Q0) 0.95 1.43 mA I DD1(Q1) 2.14 3.21 mA All Input at supply for NSi812xx0 Or All Input 0V for NSi812xx1 I DD2(Q1) 2.08 3.12 mA I DD1(1M) 1.63 2.45 mA All Input with 1Mbps, C L = 15pFI DD2(1M) 1.59 2.39 mA I (10M)2.223.33mAAll Input with 10Mbps,C O NF I D EN T IA LI DD2(10M) 2.25 3.38 mA C L = 15pFI DD1(100M) 7.57 11.36 mA All Input with 100Mbps, C L = 15pF I DD2(100M)8.5 12.75 mA Data RateDR 0 150 Mbps Minimum Pulse Width PW 5.0 nsPropagation Delayt PLH 5 9.20 15 ns See Figure 2.7 , C L = 15pF t PHL5 10.40 15 ns See Figure 2.7, C L = 15pF Pulse Width Distortion |t PHL – t PLH | PWD5.0nsSee Figure 2.7 , C L = 15pFRising Time t r 5.0 ns See Figure 2.7 , C L = 15pF Falling Timet f5.0 nsSee Figure 2.7 , C L = 15pFPeak Eye Diagram Jitter t JIT (PK) 350psChannel-to-Channel Delay Skewt SK (c2c)2.5nsPart-to-Part Delay Skew t SK (p2p)5.0ns(VDD1=2.5V± 10%, VDD2=2.5V± 10%, Ta=-40℃ to 125℃. Unless otherwise noted, Typical values are at VDD1 = 2.5V, VDD2 = 2.5V, Ta =25℃)Supply currentNSi8120I DD1(Q0) 0.53 0.8 mA All Input 0V for NSi8120x0 Or All Input at supply for NSi8120x1 I DD2(Q0) 1.11.65 mA I DD1(Q1)2.85 4.28 mA All Input at supply for NSi8120x0 Or All Input 0V for NSi8120x1 I DD2(Q1)1.15 1.73 mA I DD1(1M) 1.632.45 mA All Input with 1Mbps, C L = 15pFI DD2(1M) 1.21 1.82 mA I DD1(10M) 1.68 2.52 mA All Input with 10Mbps, C L = 15pFI DD2(10M) 2.05 3.08 mA I DD1(100M) 1.95 2.93 mA All Input with 100Mbps, C L = 15pFI DD2(100M)10.415.6mANSi8121/ NSi8122I DD1(Q0) 0.96 1.44 mA All Input 0V for NSi812xx0 Or All Input at supply for NSi812xx1I (Q0)0.931.395mAF ID EN T IA LI DD1(Q1) 2.11 3.165 mA All Input at supply for NSi812xx0Or All Input 0V for NSi812xx1 I DD2(Q1) 2.05 3.075 mA I DD1(1M) 1.58 2.37 mA All Input with 1Mbps, C L = 15pFI DD2(1M) 1.54 2.31 mA I DD1(10M) 2.02 3.03 mA All Input with 10Mbps, C L = 15pFI DD2(10M) 2.04 3.06 mA I DD1(100M) 6.03 9.045 mA All Input with 100Mbps, C L = 15pF I DD2(100M)6 9 mAData RateDR 0 150 Mbps Minimum Pulse Width PW 5.0 nsPropagation Delayt PLH 5 10 15 nsSee Figure 2.7 , C L = 15pF t PHL5 10 15nsSee Figure 2.7, C L = 15pFPulse Width Distortion |t PHL – t PLH | PWD5.0nsSee Figure 2.7 , C L = 15pFRising Time t r5.0ns See Figure 2.7 , C L = 15pF Falling Timet f5.0 ns See Figure 2.7 , C L = 15pFPeak Eye Diagram Jitter t JIT (PK)350ps Channel-to-Channel Delay Skewt SK (c2c)2.5ns Part-to-Part Delay Skew t SK (p2p)5.0ns2.2. TYPICAL PERFORMANCE CHARACTERISTICSFigure 2.1 NSi8120 VDD1 Supply Current vs Data Rate Figure 2.2 NSi8120 VDD2 Supply Current vs Data RateC OE2.3. PARAMETER MEASUREMENT INFORMATIONC LFigure 2.7 Switching Characteristics Test Circuit and WaveformFigure 2.8 Common-Mode Transient Immunity Test CircuitC O NF ID EN T IA L3.0 HIGH VOLTAGE FEATURE DESCRIPTION3.1. INSULATION AND SAFETY RELATED SPECIFICATIONSMinimum External Air Gap (Clearance)L(I01) 4.0 8.0 mm Shortest terminal-to-terminal distance through air Minimum External Tracking (Creepage)L(I02)4.08.0mmShortest terminal-to-terminal distance across the package surfaceMinimum internal gap DTI 20 um Distance through insulationTrackingResistance(Comparative Tracking Index) CTI>400VDIN EN 60112 (VDE 0303-11); IEC 60112Material GroupⅡ3.2. DIN VDE V 0884-11(VDE V 0884-11):2017-01 INSULATION CHARATERISTICSSOIC-8 SOIC-16 Installation Classification per DIN VDE 0110For Rated Mains Voltage ≤ 150V rms Ⅰto Ⅳ Ⅰto Ⅳ For Rated Mains Voltage ≤ 300V rms Ⅰto Ⅲ Ⅰto Ⅳ For Rated Mains Voltage ≤ 400V rms Ⅰto Ⅲ Ⅰto Ⅳ Climatic Classification10/105/2110/105/21 Pollution Degree per DIN VDE 0110, Table 122Maximum repetitive isolation voltageVIORM 565 849 Vpeak Input to Output Test Voltage, Method B1V IORM × 1.5 = V pd (m) , 100%production test, t ini = t m = 1 sec, partial discharge < 5 pCV pd (m)8471273VpeakInput to Output Test Voltage, Method AAfter Environmental Tests Subgroup 1V IORM × 1.2= V pd (m) , t ini = 60 sec, t m = 10 sec, partial V pd (m)6781018VpeakC O N T IA LAfter Input and /or Safety Test Subgroup 2 and Subgroup 3 V IORM × 1.2= V pd (m) , t ini = 60 sec, t m = 10 sec, partialdischarge < 5 pC V pd (m)6781018VpeakMaximum transient isolation voltage t = 60 sec VIOTM 5300 7000 Vpeak Maximum Surge Isolation VoltageTest method per IEC60065,1.2/50uswaveform, VTEST=VIOSM×1.3VIOSM53845384VpeakIsolation resistance VIO =500V RIO >109 >109 Ω Isolation capacitance f = 1MHzCIO 0.6 0.6pFInput capacitanceCI22pF Total Power Dissipation at 25℃Ps1499 mW Safety input, output, or supply currentθJA = 140 °C/W, V I = 5.5 V, T J = 150 °C, T A = 25 °C Is160mAθJA = 84 °C/W, V I = 5.5 V, T J = 150 °C, T A = 25 °C237 mA Case TemperatureTs150150℃Figure 3.2 NSi8120W/NSi8121W/NSi8122W Thermal Derating Curve, Dependence of Safety Limiting Values with Case Temperature per DIN VDE V 0884-11C O NF ID EN T IA L3.3. REGULATORY INFORMATIONThe NSi8120N/NSi8121N/NSi8122N are approved by the organizations listed in table.UL 1577 Component Recognition Program 1Approved under CSA ComponentAcceptance Notice 5ADIN VDE V 0884-11:2017-012Certified by CQC11-471543-2012 GB4943.1-2011Single Protection, 3750V rms Isolation voltageSingle Protection, 3750V rms IsolationvoltageBasic Insulation 565Vpeak, V IOSM =5384VpeakBasic insulation at 400V rms (565Vpeak)File (E500602)File (E500602)File (5024579-4880-0001)File (pending)1 In accordance with UL 1577, each NSi8120N/NSi8121N/NSi8122N is proof tested by applying an insulation test voltage ≥ 4500 Vrms for 1 sec.2 In accordance with DIN VDE V 0884-11, each NSi8120N/NSi8121N/NSi8122N is proof tested by applying an insulation test voltage ≥ 847 V peak for 1 sec(partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN VDE V 0884-11 approval.The NSi8120W/NSi8121W/NSi8122W are approved by the organizations listed in table.UL 1577 Component Recognition Program 1Approved under CSAComponent Acceptance Notice5ADIN VDE V 0884-11(VDE V 0884-11):2017-012 Certified by CQC11-471543-2012 GB4943.1-2011Single Protection, 5000V rms Isolation voltageSingle Protection, 5000V rmsIsolation voltageBasic Insulation 849Vpeak, V IOSM =5384Vpeak Basic insulation at 800V rms (1131Vpeak) Reinforced insulation at 400V rms (565Vpeak)File (E500602)File (E500602)File (5024579-4880-0001)File (pending)1 In accordance with UL 1577, each NSi8120W/NSi8121W/NSi8122W is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec.2 In accordance with DIN VDE V 0884-11, each NSi8120W/NSi8121W/NSi8122W is proof tested by applying an insulation test voltage ≥ 1273 V peak for 1 sec(partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN VDE V 0884-11 approval.4.0 FUNCTION DESCRIPTIONThe NSi812x is a Dual-channel digital isolator based on a capacitive isolation barrier technique. The digital signal is modulated with RF carrier generated by the internal oscillator at the Transmitter side. Then it is transferred through the capacitive isolation barrier and demodulated at the Receiver side.The NSi812x devices are high reliability dual-channel digital isolator with AEC-Q100 qualified. The NSi812x device is safety certified by UL1577 support several insulation withstand voltages (3.75kV rms , 5kV rms ), while providing high electromagnetic immunity and low emissions at low power consumption. The data rate of the NSi812x is up to 150Mbps, and the common-mode transient immunity (CMTI) is up to 150kV/us. The NSi812x device provides digital channel direction configuration and the default output level configuration when the input power is lost. Wide supply voltage of the NSi812x device support to connect with most digital interface directly, easy to do the level shift. High system level EMC performance enhance reliability and stability of use.The NSi812x has a default output status when VDDIN is unready and VDDOUT is ready as shown in Table 4.1, which helps for diagnosis when power is missing at the transmitter side. The output B follows the same status with the input A within 1us after powering up.C O NF ID EN T IA LCopyright © 2019, NOVOSENSEPage 12 Table 4.1 Output status vs. power statusH Ready Ready H Normal operation.L Ready Ready L XUnreadyReadyL HThe output follows the same status with the input within 60us after input side VDD1 is powered on.X Ready Unready XThe output follows the same status with the input within 60us after output side VDD2 is powered on.5.0 APPLICATION NOTE5.1. PCB LAYOUTThe NSi812x requires a 0.1 µF bypass capacitor between VDD1 and GND1, VDD2 and GND2. The capacitor should beplaced as close as possible to the package. Figure 5.1 to Figure 5.4 show the recommended PCB layout, make sure the space under the chip should keep free from planes, traces, pads and via. To enhance the robustness of a design, the user may also include resistors (50–300 Ω ) in series with the inputs and outputs if the system is excessively noisy. The series resistors also improve the system reliability such as latch-up immunity.The typical output impedance of an isolator driver channel is approximately 50 Ω, ±40%. When driving loads where transmission line effects will be a factor, output pins should be appropriately terminated with controlled impedance PCB traces.Figure5.1 Recommended PCB Layout — Top Layer Figure5.2 Recommended PCB Layout — Bottom LayerFigure5.3 Recommended PCB Layout — Top Layer Figure5.4 Recommended PCB Layout — Bottom Layer5.2. HIGH SPEED PERFORMANCEFigure 5.5 shows the eye diagram of NSi812x at 200Mbps data rate output. The result shows a typical measurement on the NSi812x with 350ps p-p jitter.C O NF ID EN T IA LFigure5.5 NSi812x Eye Diagram5.3. TYPICAL SUPPLY CURRENT EQUATIONSThe typical supply current of NSi812x can be calculated using below equations. I DD1 and I DD2 are typical supply currents measured in mA, f is data rate measured in Mbps, C L is the capacitive load measured in pFNSi8120:I DD1 = 0.19 *a1+1.45*b1+0.82*c1. I DD2 = 1.36+ VDD1*f* C L *c1*10-9When a1 is the channel number of low input at side 1, b1 is the channel number of high input at side 1, c1 is the channel number of switch signal input at side 1.NSi8121/ NSi8122:I DD1 = 0.87 +1.26*b1+0.63*c1+ VDD1*f* C L *c2*10-9I DD2 = 0.87 +1.26*b2+0.63*c2+ VDD1*f* C L *c1*10-9When b1 is the channel number of high input at side 1, c1 is the channel number of switch signal input at side 1, b2 is the channel number of high input at side 2, c2 is the channel number of switch signal input at side 2.6.0 PACKAGE INFORMATIONVDD GND 22VDD INA GND 2VDD 2Figure 6.1 NSi8120N Package Figure 6.2 NSi8121N PackageC O NF ID EN T IA LVDD INBGND 22Figure 6.3 NSi8122N PackageFigure 6.4 SOIC8 Package Shape and Dimension in millimeters (inches)Table6.1 NSi8120N/ NSi8121N/ NSi8122N Pin Configuration and DescriptionNSi8121N PIN NO.NSi8122N PIN NO.SYMBOL FUNCTION1 1 1 VDD1 Power Supply for Isolator Side 12 7 2 INA Logic Input A3 3 6 INB Logic Input B4 4 4 GND1 Ground 1, the ground reference for Isolator Side 15 5 5 GND2 Ground 2, the ground reference for Isolator Side 26 6 3 OUTB Logic Output B7 2 7 OUTA Logic Output A888VDD2Power Supply for Isolator Side 2C O NFVDD GND GND 2VDD 2GND 2GND NC NCNC VDD GND GND 2VDD 22GND NC NC NCFigure 6.5 NSi8120W Package Figure 6.6 NSi8121W PackageVDD INB GND GND 2VDD 2GND 2GND NC NC NCFigure 6.7 NSi8122W PackageFigure 6.8 WB SOIC16 Package Shape and Dimension in millimeters and (inches)C O NF ID EN T IA LTable 6.2 NSi8120W/ NSi8121W/ NSi8122W Pin Configuration and Description1 1 1 GND1 Ground 1, the ground reference for Isolator Side 12 2 2 NC No Connection.3 3 3 VDD1 Power Supply for Isolator Side 14 13 4 INA Logic Input A5 5 12 INB Logic Input B6 6 6 NC No Connection.7 7 7 GND1 Ground 1, the ground reference for Isolator Side 18 8 8 NC No Connection. 9 9 9 GND2 Ground 2, the ground reference for Isolator Side 210 10 10 NC No Connection. 11 11 11 NC No Connection. 12 12 5OUTB Logic Output A 13 4 13OUTALogic Output B 14 14 14 VDD2 Power Supply for Isolator Side 215 15 15 NC No Connection.161616GND2Ground 2, the ground reference for Isolator Side 27.0TAPE AND REEL INFORMATIONLAITNEDIFNOCC O NF ID EN T IA LFigure 7.1 Tape and Reel Information of SOIC8LAITNEDIFNOCFigure 7.2 Tape and Reel Information of WB SOIC16NF ID EN T IA L8.0 ORDER INFORMATIONNSi8120N0 3.75 2 0 150 Low -40 to 125℃ NO SOIC8 NSi8120N1 3.75 2 0 150 High -40 to 125℃ NO SOIC8 NSi8121N0 3.75 1 1 150 Low -40 to 125℃ NO SOIC8 NSi8121N1 3.75 1 1 150 High -40 to 125℃ NO SOIC8 NSi8122N0 3.75 1 1 150 Low -40 to 125℃ NO SOIC8 NSi8122N1 3.75 1 1 150 High -40 to 125℃ NO SOIC8 NSi8120W0 5 2 0 150 Low -40 to 125℃ NO WB SOIC16 NSi8120W1 5 2 0 150 High -40 to 125℃ NO WB SOIC16 NSi8121W0 5 1 1 150 Low -40 to 125℃ NO WB SOIC16 NSi8121W1 5 1 1 150 High -40 to 125℃ NO WB SOIC16 NSi8122W0 5 1 1 150 Low -40 to 125℃ NO WB SOIC16 NSi8122W1 5 1 1 150 High -40 to 125℃ NO WB SOIC16 NSi8120N0Q 3.75 2 0 150 Low -40 to 125℃ YES SOIC8 NSi8120N1Q 3.75 2 0 150 High -40 to 125℃ YES SOIC8 NSi8121N0Q 3.75 1 1 150 Low -40 to 125℃ YES SOIC8 NSi8121N1Q 3.75 1 1 150 High -40 to 125℃ YES SOIC8 NSi8122N0Q 3.75 1 1 150 Low -40 to 125℃ YES SOIC8 NSi8122N1Q 3.75 1 1 150 High -40 to 125℃ YES SOIC8 NSi8120W0Q 5 2 0 150 Low -40 to 125℃ YES WB SOIC16 NSi8120W1Q 5 2 0 150 High -40 to 125℃ YES WB SOIC16 NSi8121W0Q 5 1 1 150 Low -40 to 125℃ YES WB SOIC16 NSi8121W1Q 5 1 1 150 High -40 to 125℃ YES WB SOIC16 NSi8122W0Q 5 1 1 150 Low -40 to 125℃ YES WB SOIC16 NSi8122W1Q 5 1 1 150 High -40 to 125℃YES WB SOIC16 NOTE: All packages are RoHS-compliant with peak reflow temperatures of 260 °C according to the JEDEC industry standard classifications and peak solder temperatures. All devices are AEC-Q100 qualified.Part Number Rule:NSi(81)(2)(1)(N)(1)(Q)C O NF ID EN T IA LNSi8120/NSi8121/NSi81229.0 REVISION HISTORY1.0 Original2017/11/15 1.1 Change to Ordering information2018/3/26 1.2 Add maximum operation current specification. 2018/6/20 1.3 Change block diagram 2018/7/28 1.4 Correct Table 6.2 Pin No.2018/8/20 1.5 Add specification “Input Pull high or low Current” 2018/9/10 1.6 Add “Maximum Input/Output Pulse Voltage” 2018/10/91.7 Change to Ordering information 2018/12/20 1.8 Change Certification Information2019/06/17。
Product datasheetCharacteristicsLC1F185U7TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 185 A - coil 240 V ACPrice* : 564.59 GBPMainRange TeSys Product nameTeSys F Product or component type Contactor Device short name LC1F Contactor application Resistive load Motor control Utilisation categoryAC-4AC-1AC-3Poles description3P Power pole contact composition 3 NO[Ue] rated operational voltage <= 460 V DC<= 690 V AC 50/60 Hz[Ie] rated operational current 275 A (at <40 °C) at <= 440 V AC-1185 A (at <55 °C) at <= 440 V AC-3Motor power kW90 kW at 380...400 V AC 50/60 Hz (AC-3)100 kW at 415 V AC 50/60 Hz (AC-3)100 kW at 440 V AC 50/60 Hz (AC-3)110 kW at 500 V AC 50/60 Hz (AC-3)110 kW at 660...690 V AC 50/60 Hz (AC-3)55 kW at 220...230 V AC 50/60 Hz (AC-3)33 kW at 400 V AC 50/60 Hz (AC-4)[Uc] control circuit voltage240 V AC 40...400 HzComplementary[Uimp] rated impulse withstand voltage 8 kV Overvoltage categoryIII[Ith] conventional free air thermal current275 A (at 40 °C)Rated breaking capacity1480 A conforming to IEC 60947-4-1i s c l a i m e r : T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s[Icw] rated short-time withstand current1500 A 40 °C - 10 s920 A 40 °C - 30 s740 A 40 °C - 1 min500 A 40 °C - 3 min400 A 40 °C - 10 minAssociated fuse rating200 A aM at <= 440 V315 A gG at <= 440 VAverage impedance0.33 mOhm - Ith 275 A 50 Hz[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group CPower dissipation per pole12 W AC-325 W AC-1Mounting support PlateStandards IEC 60947-1JIS C8201-4-1EN 60947-1IEC 60947-4-1EN 60947-4-1Product certifications LROS (Lloyds register of shipping)ULCSABVCBDNVRMRoSRINAABSConnections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mmPower circuit: lugs-ring terminals 1 cable(s) 150 mm²Power circuit: connector 1 cable(s) 150 mm²Power circuit: bolted connectionTightening torque Control circuit: 1.2 N.mPower circuit: 18 N.mControl circuit voltage limits Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)Drop-out: 0.35...0.55 Uc 40...400 Hz (at 55 °C)Inrush power in VA1070 VA 40...400 Hz cos phi 0.9 (at 20 °C)Hold-in power consumption in VA9.9 VA 40...400 Hz cos phi 0.9 (at 20 °C)Heat dissipation8…9.8 WOperating time35 ms closing (at Uc)130 ms opening (at Uc)Mechanical durability10 McyclesMaximum operating rate2400 cyc/h 55 °CCompatibility code LC1FMotor power range30…50 kW at 200…240 V 3 phases55…100 kW at 200…240 V 3 phases55…100 kW at 380…440 V 3 phases55…100 kW at 480…500 V 3 phases110…220 kW at 480…500 V 3 phasesMotor starter type Direct on-line contactorContactor coil voltage240 V AC standardEnvironmentIP degree of protection IP2x front face with shrouds conforming to IEC 60529IP2x front face with shrouds conforming to VDE 0106Protective treatment THAmbient air temperature for operation-5…55 °CAmbient air temperature for storage-60…80 °CPermissible ambient air temperature-40…70 °Caround the deviceOperating altitude3000 m withoutHeight174 mmWidth168.5 mmDepth181 mmProduct weight 4.65 kgOffer SustainabilitySustainable offer status Green Premium productREACh Regulation REACh DeclarationEU RoHS Directive CompliantEU RoHS DeclarationMercury free YesRoHS exemption information YesChina RoHS Regulation China RoHS declarationProduct out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Product Environmental ProfileCircularity Profile End of Life InformationWEEE The product must be disposed on European Union markets following specific waste collection andnever end up in rubbish binsContractual warrantyWarranty18 monthsProduct datasheetLC1F185U7Dimensions DrawingsDimensions and DrawingsLC1 F115 to F330(1)Power terminal protection shroudX1 (mm) = Minimum electrical clearance according to operating voltage and breaking capacity.TeSys F reversing contactors and changeover contactor pairs, vertically mountedNOTE: For customer assembly, with mechanical interlock (MI) LA9 F, fixing recommended on AM1 EC uprights (please consult your Regional Sales Office). 2 x LC1 identical or different ratings (LC1 F115 to F630 and F800).Assembly A(1)Mechanical interlock shaft.(2)For assembly of contactors of different ratings only.(3) 4 x Ø6.5 for LC1 F115 to F225.(7)Assembly B(4) 4 x Ø6.5 for LC1 F265.(5)Mechanical interlock guide bracket.(7)Assembly C(6) 4 x Ø8.5 for LC1 F400, F500 or 4 x Ø10.5 for LC1 F630 and F800.(7)Only 3P for F800.(8)In this case, G4 is greater than G5.Assembly C(7)Product datasheetLC1F185U7 Connections and SchemaConnections and Schema2, 3, and 4-pole ContactorsLC1 F115 to F630, F1250(coil LX1 F )LC1 F115 to F630 , F1250 (coil LX4 F )LC1 F115 to F265 (coil LX9 F )LC1 F800 (coil LX8 F / )。