海尔bd93说明书
- 格式:docx
- 大小:32.95 KB
- 文档页数:30
H-1H LOW FLOW MAGMETERFMG80A SeriesU No Moving PartsU R equires No Straight PipeU P ulse and/or 4 to 20 mA OutputU C hemical and Corrosion ResistantU I nsensitive to Fluid Density and Fluid Viscosity ChangesU NEMA 4X (IP66)FMG82A The FMG80A Series magmeter is designed for low-flow chemical injection or difficult-to-meter applications with pulsating meter-ing pumps in ¹⁄₄ to ³⁄₄" pipe/tube. The housing is made of sturdy splash-proof HDPE plastic.With no moving parts, the FMG80A Series can handle fluids containing particulate matter without clogging or jamming, keeping maintenance at a minimum. With no metallic parts (100% PVDF body and PVDF carbon fiber-filled electrodes), the meter is corrosion-resistant and compatible with a wide range of chemicals. Accuracy is maintained with conductive fluids (>20 micro Siemens) of varying viscosities and densities.The FMG80A Series meter is compact enough to fit most pump/injection systems. With zero straight pipe required after an elbow, it can be easily mounted in tight spaces. The mounting bracket adds stability.The FMG80A Series meter has opto-coupled current sinking or current sourcing pulse as well as a 4 to 20 mA output that can be connected to many OMEGA ® panel meters, controllers and data loggers; outputs and power are provided through a 6 m (19.7') cable with 8-pin female circular connector.SPECIFICAtIONS Pipe Sizes: 1⁄4, 3⁄8, ½, and ¾"Fittings: Fittings with two NPT threaded adaptors (included)Materials Body: PVDF Electrodes: PVDF carbon fiber-filled Ground: PVDF carbon fiber-filled Housing: HDPE with glass fiber Fittings: PVDF Adaptors (NPt): PVDF or polypropylene temperature: Ambient: -18 to 54ºC (0 to 130ºF) Fluid: 0 to 93ºC (32 to 200ºF)Pressure: 150 psi Flow Range: FMG81A, FMG82A: 3 GPM max (0.03 GPM cut off) FMG83A, FMG84A: 20 GPM max (0.2 GPM cut off)Accuracy: F MG81A, FMG82A: ±1%, ±0.002 GPM of reading across rated range FMG83A, FMG84A: ±1%, ±0.005 GPM of reading across rated range Output Signal: Optocoupled current sinking or current sourcing pulse output; 30 Vdc, 5 mA max, 4 to 20 mA current loop; 7 Vdc plus load voltage drop min; 50 Vdc max FMG81A, FMG82A: 1000 pulses/liter (3785 pulses/gallon) FMG83A, FMG84A: 500 pulses/liter (1892 pulses/gallon) Power: 10 to 15 Vdc, 150 mA (linear power supply recommended)Fluid Conductivity: >20 microSiemens Environmental: NEMA 4X (IP66)Cable Length: 6 m (19.7'), cable with 8-pin female circular connectorH-2Ordering Examples: FMG81A magmeter 1⁄4 NPT, 3 GPM and DPF701 1⁄8 DIN digital panel meter. For technical information on DPF701 visit OMEGA.FMG84A magmeter 3⁄4 NPT, 20 GPM and DPF65 1⁄8 DIN batch controller. For technical information on DPF65 visit OMEGA.。
Serie | 2, Forno da incasso, 60 x 60 cm, Acciaio inoxHBA510BR0CAccessori integrati1 x Griglia combinata1 x Leccarda universale smaltataAccessori specialiHEZ317000 Teglia per pizza, HEZ327000 Pietra per pane e pizza,HEZ333001 Coperchio per leccarda extra profonda, HEZ5300002 leccarde slim 455x188x39 mm (LxPxA), HEZ531000 Leccardabassa 455x375x30 mm (LxPxA), HEZ531010 Leccarda antiaderen455x375x30mm (LxPxA), HEZ532000 Leccarda profonda455x375x38 mm (LxPxA), HEZ532010 Leccarda antiaderen455x400x38mm (LxPxA), HEZ533000 Leccarda profonda455x375x81 mm (LxPxA), HEZ538000 Guide telescopiche clip a1 livello, HEZ538200 Guide telescopiche a2 livelli, HEZ538S00Guide telescop. a 2 livelli+1 guida clip, HEZ625071 Teglia pergrigliare adatta a pirolisi, HEZ633001 Coperchio per tegameprofessionale, HEZ633070 Tegame professionale, HEZ636000Leccarda in vetro 455x364x30 mm (LxPxA), HEZ638300 Setgriglie telesc.3 liv.ad pl, HEZ660050 Accessory,HEZ915003 Pirofila in vetro con coperchio 5,4 l.Un forno da incasso con funzioneventilata 3D: così ottenete cottureperfette cucinando su tre livelli diversi incontemporanea.Aria calda 3D: risultati perfetti grazie alla distribuzioneottimale del calore.Dati tecniciColore/materiale del frontale : Acciaio inoxDa incasso / a libera installazione : Da incassoSistema di pulizia : NoDimensioni del vano per l'installazione : 585-595 x 560-568 x550Dimensioni del prodotto (mm) : 595 x 594 x 548Dimensioni del prodotto imballato (mm) : 675 x 690 x 660Materiale del cruscotto : acciaio inoxMateriale porta : vetroPeso netto (kg) : 33.979Volume utile : 71Metodo di cottura : aria calda, Grill a superficie grande,grill ventilato, Hotair gentle, riscaldamento superiore/infer.Materiale della cavit : OtherRegolazione della temperatura : MeccanicoNumero di luci interne : 1Certificati di omologazione : CE, VDECodice EAN : 4242005139392Number of cavities (2010/30/EC) : 1Classe di efficienza energetica (2010/30/EC) : AEnergy consumption per cycle conventional (2010/30/EC) :0.97Energy consumption per cycle forced air convection (2010/30/EC) : 0.81Indice di efficienza energetica (2010/30/CE) : 95.3Dati nominali collegamento elettrico (W) : 3400Corrente (A) : 3*10Tensione (V) : 400Frequenza (Hz) : 50; 60Tipo di spina : collegamento fisso, senza spina'!2E20A F-b d j d j c!1/3Serie | 2, Forno da incasso, 60 x 60 cm,Acciaio inoxHBA510BR0CUn forno da incasso con funzione ventilata3D: così ottenete cotture perfette cucinandosu tre livelli diversi in contemporanea.Tipo di forno e modi di riscaldamento-Volume interno: 71 l-Riscaldamento rapidoSupporto per accessori / Sistema d`estrazione:-Guide telescopiche accessorio opzionaleDesign-Illuminazione interna alogena-XXL- Forno con email granitPuliziaComfortAccessorio:-1 x Griglia combinata, 1 x Leccarda universale smaltataAmbiente e SicurezzaInformazioni tecniche-Dimensioni nicchia (AxLxP): 585 mm - 595 mm x 560 mm -568 mm x 550 mm-Dimensioni apparecchi (AxLxP): 595 mm x 594 mm x 548 mm-Potenza max. assorb. (elettr.): 3.4 kW-Si prega di fare riferimento alle quote d'installazione mostratenel disegno tecnico-Classe di efficienza energetica (acc. EU Nr. 65/2014): AConsumo energetico per ciclo durante funzionamentoconvenzionale: 0.97 kWh Consumo energetico per ciclodurante funzionamento ventilato: 0.81 kWh Numero di cavità:1 Tipo di alimentazione: elettrica Volume della cavità: 71 l2/3Serie | 2, Forno da incasso, 60 x 60 cm,Acciaio inoxHBA510BR0C3/3。
本产品的用户使用手册文档版权归上海辉度智能系统有限公司所有,其保留所有权力。
上海辉度智能系统有限公司有权利在任何时间改进本文档涉及的产品内容。
任何个人或公司都不允许再版、拷贝、翻译及传播本文档的任何部分。
郑重承诺:凡上海辉度智能系统有限公司产品从购买即日起一年内无任何材料性缺损。
凡使用本系列产品除产品质量所造成的损害,上海辉度智能系统有限公司不承担任何法律责任。
上海辉度智能系统有限公司有义务提供本系列产品可靠而详尽资料,但保留修订权利,且不承担使用者非法利用资料对第三方所造成侵害构成的法律责任。
如果你有任何的问题,欢迎联系我们,我们会尽快回答您的问题。
公司:上海辉度智能系统有限公司网址:电话:(86-21)37774020传真:(86-21)37774010邮编:201100邮箱:****************地址:上海闵行区中春路7001号明谷科技园目录第一章基本介绍 (2)1.1概述 (3)第二章产品安装配置 (4)2.1产品正面图 (5)2.1.1安装尺寸 (5)2.1.2产品配件清单 (6)2.1.3产品安装向导 (7)第三章模块功能简介 (8)3.1功能参数说明 (9)3.1.1系统参数 (9)3.1.2端子功能描述 (10)3.1.3LED灯说明 (10)3.1.4技术规范 (10)第一章1.1概述WTD93LG网关是一款与Bosch的TDL模块联合使用,形成货物运输情况监控以及存储的一体解决方案。
WTD93LG通过低功耗蓝牙BLE协议采集Bosch的TDL采集到的震动,温湿度信息。
WTD93LG的GPS的定位系统快速定位运输过程中的温湿度异常变化,或者剧烈震动的地方,并通过无线通信技术向服务器定时发送采集到的数据。
WTD93LG网关内部集成了高性能和超低功耗为一体的CPU,具有快速的数据交换及逻辑处理能力。
射频核心硬件由世界知名通信厂商设计生产,具有很高的网络稳定性,内置看门狗保证设备运行安全可靠。
型号目录产品特点................2安全注意事项..........2技术数据与装箱单...3安装指导. (4)产品使用说明 (5)故障排除及处理.......8使用前请仔细阅读说明书本公司保留说明书解释权产品外观以实物为准如遇产品技术改进,恕不另行通知本产品只适合在中国大陆销售和使用本产品执行标准:GB 16410-2020 GB 30720-2014产品部件介绍..........4清洁保养................7告用户环境影响书....8保修说明. (9)系列QHA938U1系列QHA93T1系列QHA73T112意外熄火保护功能欧式风格设计当火焰因风吹、溢锅等发生意外熄火后,熄火保护装置会动作,自动切断燃气灶内部的燃气通路,避免燃气大量泄漏,确保用户使用安全。
瞬燃点火功能点火采用瞬燃点火技术,只需要将旋钮按压到底并旋转90°,燃气灶就能实现瞬间开阀,实现快速点火功能。
采用优质钢化玻璃灶面,高强度,易清洁。
联网APP 操控功能(仅QHA938U1机型有此功能)使用海尔智家APP 可以进行定时、关火等操控。
定时功能(仅QHA938U1机型有此功能)烹饪过程中,左右灶头均可设置(1~180)min 的超长定时。
干烧保护功能(仅左灶头具有此功能)在使用该燃气灶的时候,若在大火加热时忘记关火而造成锅底温度过热,超过保护警戒温度时,防干烧过热保护装置将启动,发出“滴2s 停1s ”蜂鸣声(持续约20s )并切断燃气,避免因烧干锅引发火灾等安全事故;(请确保锅底和传感器有效接触,否则干烧保护功能不能可靠启动;该功能一般在锅具彻底烧干几分钟内启动;当锅内食物刚刚烧干、烧糊时,并不能立即关火。
)干烧保护后,若立即进行重新点火,则不能点火成功,待干烧保护恢复后才能正常点火。
不坐锅智能关火功能(仅左灶头具有此功能)若您将左灶头处于大火燃烧一段时间后,并且在支锅架不放置锅具,那么不坐锅智能关火功能会启动,发出“滴2s 停1s ”蜂鸣声(持续约20s )并切断燃气,为您节省燃气并保证您的安全;(如果传感器探头没有和锅底有效的接触,不坐锅智能关火功能判断为无锅状态,可能会报警并切断燃气。
Series 8, Built-in oven, 60 x 60 cm, Stainless steelHBG672BS1BIncluded accessories2 x combination grid, 1 x universal panOptional accessoriesHEZ324000 Inlaid wire shelf for multipurpose pan, HEZ327000 Pizza stone, HEZ617000 Pizza pan, enamelled, HEZ625071 Grill tray, anthracite enamelled, HEZ631070 Baking tray, enamelled,HEZ632070 Multipurpose pan, enamelled, HEZ633001 Lid for professional pan, enamelled, HEZ633070 Professional pan, enamelled, HEZ634000 Baking and roasting grid (standard),HEZ636000 Glass pan, HEZ638170 1 level telescopic rail, full ext, pyro, HEZ638270 2 level telescopic rails, full ext,pyro, HEZ638370 3 level telescopic rails, full ext,pyro, HEZ660050 Cover Strip,HEZ6BCA0 Cookbook, HEZ864000 Glass tray, HEZ9020 Conversion cabinet, HEZ9041 Conversion cabinet, HEZ915001 Glass roasting dish, 5,1 L The built-in oven: you get perfect baking and roasting results.• 4D Hotair: even heat distribution for perfect results – on any level.• TFT display control: easy-to-use thanks to the control ring with full text and symbols.• Pyrolytic self-cleaning: Automatically cleans the oven, just wipe out the ash.• Drop down door with SoftOpen and SoftClose: the oven door opens and closes gently and quietly• Fast pre heatingTechnical DataInstallation type: ......................................................................Built-in Integrated Cleaning system: ..................................................Pyrolytic Min. required niche size for installation (HxWxD): 585-595 x 560-568 x 550 mmDimensions: ........................................................595 x 595 x 548 mm Dimensions of the packed product (HxWxD): .....670 x 680 x 670 mm Control Panel Material: ................................................Stainless steel Door Material: ............................................................................Glass Net weight: ..............................................................................37.7 kg Usable volume of cavity: ...............................................................71 l Cooking method: .....4D Hotair, Defrost, Full width grill, Hot Air-Eco, Conventional heat, Conventional heat ECO, Pizza setting, Hot air grillingOven control: ......................................................................electronic Number of interior lights: .. (1)Length of electrical supply cord: ..........................................120.0 cm EAN code: (4242002881539)Number of cavities (2010/30/EC): (1)Energy efficiency rating: ..................................................................A+ Energy consumption per cycle conventional (2010/30/EC): ........0.87 kWh/cycleEnergy consumption per cycle forced air convection (2010/30/EC):0.69 kWh/cycleEnergy efficiency index (2010/30/EC): .....................................81.2 % Connection rating: ..................................................................3600 W Fuse protection: ...........................................................................16 A Voltage: ...............................................................................220-240 V Frequency: ...........................................................................50; 60 Hz Plug type: .....................no plug (electrical connection by electrician) Included accessories: .............2 x combination grid, 1 x universal panSeries 8, Built-in oven, 60 x 60 cm, Stainless steelHBG672BS1BThe built-in oven: you get perfect baking and roasting results.Key Information- 2.5“-TFT colour and text display with direct select buttons- Drop down door, SoftClose, SoftOpen- Digital temperature display with proposal- Actual temperature display Heating-up indicator- Automatic programmes- Pyrolytic self-cleaning function- Pyrolytic proof baking trayDesign- Bosch control wheel- Straight bar handleFeatures- Electronic clock timer- Main on/off switch- 1 interior light- Interior halogen light, Light on/off when oven door opened/closed - Light on/off when oven door opened/closed- Control panel lock- Automatic safety switch off Residual heat indicator Start button Door contact switch- Cavity inner surface: enamel anthracite- Removable wire shelf support rails- 5 shelf positions- Full glass inner door- Info buttonProgrammes/functions- Oven with 8 cooking functions:, 8 cooking functions: heating methods: 4D Hotair, Hotair Gentle, conventional top and bottom heat, conventional heat Gentle, Hotair grilling, full width variable grill, pizza function, defrost- Fast pre-heating functionPerformance/technical information- Temperature range 30 °C - 275 °C- Cavity volume: 71 litre capacity- Integral cooling fan- Stainless-steel fan- 120 cm Cable length- Total connected load electric: 3.6 KW- Appliance dimension (hxwxd): 595 mm x 595 mm x 548 mm- Niche dimension (hxwxd): 585 mm - 595 mm x 560 mm - 568 mm x 550 mm- Please refer to the dimensions provided in the installation manual - Maximum window temperature 30° C- Energy efficiency rating (acc. EU Nr. 65/2014): A+- Energy consumption per cycle in conventional mode:81.2- Energy consumption per cycle in fan-forced convection mode:0.69 kwh - Number of cavities: 1 Cavity volume:71 litre capacity Standard accessories- Available as an additional accessory- 2 x combination grid, 1 x universal panSeries 8, Built-in oven, 60 x 60 cm,Stainless steel HBG672BS1B。
FOR SERVICE TECHNICIAN’S USE ONL YFOR SERVICE TECHNICIAN’S USE ONL YFOR SERVICE TECHNICIAN’S USE ONL Y324FOR SERVICE TECHNICIAN’S USE ONL YT ech SheetDo not discardFOR SERVICE TECHNICIAN’S USE ONLYPRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGYa. Do not operate or allow the oven to be operated with the dooropen.b. Make the following safety checks on all ovens to be servicedbefore activating the magnetron or other microwave source, and make repairs as necessary:1. Interlock Operation 2. Proper Door Closing3. Seal and Sealing Surfaces (Arcing, Wear and Other Damage)4. Damage to or Loosening of Hinges and Latches5. Evidence of Dropping or Abusec. Before turning on microwave power for any service test orinspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity and connections.d. Any defective or misadjusted components in the interlock,monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.e. A microwave leakage check to verify compliance with the FederalPerformance Standard should be performed on each oven prior to release to the owner.f. Do not attempt to operate the oven if the door glass is broken.FAILURE CODE INDICATIONSNOTE: Many of the problems listed in the chart below may be solved by power cycling: Unplug microwave oven or disconnect power. After 1 minute, plug in microwave oven or reconnect power.Display Likely Failure Condition Recommended Repair Procedure“Enter clock”Power failureAfter a power failure, “Enter clock” will be flashing. Press CANCEL to end this indication. The colon (:) will appear when in Standby mode.F1E4Microwave ACU failure 1. Unplug microwave oven or disconnect power.2. Replace ACU.3. Replace all parts and panels before operating.4. Plug in microwave oven or reconnect power.F2E1Stuck key failure1. Unplug microwave oven or disconnect power.2. Replace touch panel.3. Replace all parts and panels before operating.4. Plug in microwave oven or reconnect power.F4E4Humidity sensor error 1. Enter the Diagnostics mode (press CANCEL - CANCEL- START), and then press COOK TIME to display the humidity sensor reading. If display does not show “3789,” continue to Step 2. Press COOK POWER to display the RH sensor NTC reading. If display does not show “026,” continue to Step 2.2. Unplug microwave oven or disconnect power.3. Connect a new humidity sensor ACU to cable.4. Replace all parts and panels before operating.5. Plug in microwave oven or reconnect power.6. Enter the Diagnostics mode (press CANCEL - CANCEL - START), then press COOKTIME, and then press COOK POWER to see if failure code reappears.NOTE: There may be a delay (approximately 1 minute, 20 seconds) before the F4E4 failure code is displayed.7. If the F4E4 failure code reappears, unplug microwaveoven or disconnect power.8. Replace ACU.9. Replace all parts and panels before operating.10. Plug in microwave oven or reconnect power.F8E5Exhaust air templatedetection failure1. Enter the Diagnostics mode (pressCANCEL - CANCEL - START), and then press OPTIONS/CLOCK to display the exhaust air temperature sensor reading. Verify the sensor temperature reading is at room temperature (typically 50ºF to 90ºF [10ºC to 32ºC]) and verify failure code. If failure code matches complaint, continue to Step 2.2. Unplug microwave oven or disconnect power.3. Disconnect sensor from ACU.4. Measure sensor resistance between connector pinsand confirm reading is between 9.5 kΩ and 10.5 kΩ at room temperature. If measurement is not correct, or if a short or open circuit is found, replace sensor.5. Replace all parts and panels before operating.6. Plug in microwave oven or reconnect power.7. Enter the Diagnostics mode (pressCANCEL - CANCEL - START), and then pressOPTIONS/CLOCK to display the cavity temperature sensor reading. Verify the sensor temperature reading. If it is still not correct, replace ACU.8. If failure does not reappear, stop.PRIMARY , MONITOR, SECONDARY , AND DOOR INTERLOCK SWITCH CHECKOUT PROCEDURESIMPORTANT: Before checking the interlock switches, unplug microwave oven or disconnect power. Be sure to disconnect all of the wires at the switch being tested before making any continuity readings.NOTE: The Primary Interlock switch, Monitor Interlock switch, Secondary Interlock Switch, and Door Interlock Switch are mounted in the door lockswitch cradle. All the Interlock Switches can be identified by the wire colors that are connected to the terminals of the switches. See the chart below for wire color designation.SwitchCheck ByDoor OpenDoor ClosedPrimary Interlock1. Unplug microwave oven or disconnect power.2. Disconnect the wires at the Primary Interlock Switch.3. Check from the common terminal (black/brown wires) to the normally open terminal(black/white wires).4. Reconnect wires to switch.-+Monitor Interlock 1. Unplug microwave oven or disconnect power.2. Disconnect the wires at the Monitor Interlock Switch.3. Check from the common terminal (white wire) to the normally closed terminal(blue/white wires).4. Reconnect wires to switch.+-Secondary Interlock 1. Unplug microwave oven or disconnect power.2. Disconnect the wires at the Secondary Interlock Switch.3. Check from the common terminal (white/blue wires) to the normally open terminal(blue/blue wires).4. Reconnect wires to switch-+Door Interlock 1. Unplug microwave oven or disconnect power.2. Disconnect the wires at the Door Interlock Switch.3. Check from the common terminal (blue wire) to the normally closed terminal(orange wire).4. Reconnect wires to switch.+-(+) Continuity (-) No ContinuityM W O v e n R u n n i n g —A C V R e a d i n g sP i n N a m eW i r e C o l o rP o w e r O n , D o o rC l o s e dP o w e r O n , D o o r O p e nH o o d F a n M o t o r —H i g hH o o d F a n M o t o r —H i g h , D o o r O p e nH o o d F a n M o t o r —M e d -H i g hH o o d F a n M o t o r —M e d -H i g h , D o o r O p e nH o o d F a n M o t o r —M e d i u mH o o d F a n M o t o r —M e d i u m , D o o r O p e nH o o d F a nM o t o r —L o wH o o d F a n M o t o r —L o w , D o o r O p e nH o o d L i g h t —H ig hH o od L i g h t —H i g h , D o o r O pe nH o o d L i g h t —L o wH o o d L i g h t —L o w , D o o r O p e nM W O v e n S t a r t P1-1 (L)Brown 120120120120120120120120120120120120120120120P1-3 (N)White 00 0000000000000P2-3 (NFS)White 0120012001200120012001200120 3.6P2-2 (Door)Orange 012001200120012001200120012049P2-1 (N)Green 000000000000000P4-4 (HF)White 01200120012001200120012000120P4-5 (TTM)Red 0120012001200120012001200120120P4-1 (HL)Yellow 00000000001201206767 2.4P4-2 (HF-R)Gray 00120120120120585877770000 3.6P4-3 (HF-Hi)Black001201206868585839390000 3.7P4-6 (CL)Green151151120120555577773.7CONNECTORS ON ACUTOUCH P ANELT ouch Panel and ACU T estThe microwave hood combination is provided with a self-diagnostic routine that can be accessed through the touch keypad.T o initiate this routine:1. Plug in microwave oven or reconnect power, and press CANCEL tostandby (“:”).2. Close door, then press CANCEL - CANCEL - START within3 seconds.3. All display segments will be lit to indicate the Test mode has beenentered.NOTE: If CANCEL is pressed during this diagnostic routine, you will exit the Test mode.ACU21P41 2 3 4 5 6Relay 4903P11 3L N.P91 2P111 2 3 4P6 3 2 1P21 2 3P3 14 13 12 11 10 9 8 7 6 5 4 3 2 1P71234567891011Relay 490321NOTE: There are purposely emptyterminals between each of the numbered terminals on P1 connector.W11268419ANOTE: These diagrams are not intended to show a complete circuit; they represent the position of switches during “DOOR OPEN” or “DOOR CLOSED” (continuity checks only).NOTE: Interlock, Monitor switches and Door interlock switch cannot be adjusted and all these switches should be replaced if any one of them is found to be defective. After replacing interlock/monitor switches, reconnect wires to switch and check for continuity. Safety interlocks and monitor switches will actuate within 2 mm.Door ClosedDoor OpenNOT HEATING TROUBLESHOOTING INSTRUCTIONIMPORTANT: High-voltage is present at the magnetron and high-voltage capacitor terminals. Avoid direct contact when power is connected to these components to avoid serious injury or possible death. Always be sure that the high-voltage capacitor is discharged before accessing any of these components.For a no-heat condition, refer to the following step-by-step instructions:1. Unplug microwave oven or disconnect power.2. Discharge the high-voltage capacitor.3. Disconnect the high-voltage transformer primary windings.4. Attach the voltmeter leads to the high-voltage transformer primaryinput wires.5. Plug in microwave oven or reconnect power.6. Close door and program the microwave oven to operate for30 seconds.7. Press START.8. Check the input voltage at the high-voltage transformer primary inputwires. If the voltage is not close to the rating voltage 120 +/-15 VAC, unplug microwave oven or disconnect power. Check the circuitry as follows:■Measure resistance of the fuse, microswitches and thermostats. Replace any failed components. (Refer to the wiring diagram.)■Check for loose terminals. (Refer to the wiring diagram.) Check all of the terminals on the main route from the power supply to the high-voltage transformer.■Check for loose or failed connectors on the ACU (P1, P2, P4). Ifthese check out OK, plug in microwave oven or reconnect power. ■Check for ACU failure. Refer to the “ACU Pin Voltage Matrix” section.9. If the input voltage at the high-voltage transformer primary inputwires is close to the rating voltage 120 +/-15 VAC, unplug microwave oven or disconnect power.10. Check the power supply components. Refer to the “ComponentTests” section.■High-voltage transformer ■High-voltage capacitor■High-voltage diode11. If the power supply components check out OK, check the connectionbetween the magnetron and the high-voltage transformer.12. If all of the components check out OK, replace the magnetron.13. Reconnect the high-voltage transformer primary windings.ACU PIN VOLTAGE MATRIXCheck for proper voltage by completing the following steps:1. Unplug microwave oven or disconnect power.2. Connect voltage measurement equipment to the terminals listedbelow. (P1-3 and P2-3 are neutral.) 3. Plug in microwave oven or reconnect power, and confirm voltagereading.4. Unplug microwave oven or disconnect power.NOTE: For 50 V and over, the tolerance is +/-15 V . For 0 V , the tolerance is +/-3 V .AbbreviationsHL – Hood LightN – NeutralCL – Cavity LightHF – Hood FanL – Line VoltageTT – Turntable MotorNFS – Neutral for SwitchNOTE: When checking voltage readings on ACU, connect the grounding test lead of voltmeter to P1-3, P2-1. Use the positive test lead to probe connectors designated below.Door Interlock SwitchSecondary Interlock Switch(NO)Interlock SwitchDoor Interlock SwitchMW Oven Plugged In—Sitting Idle—ACV ReadingsFOR SERVICE TECHNICIAN’S USE ONL Y FOR SERVICE TECHNICIAN’S USE ONL YFOR SERVICE TECHNICIAN’S USE ONL Y FOR SERVICE TECHNICIAN’S USE ONL Y 57608/18FOR SERVICE TECHNICIAN’S USE ONLYW11268419A©2018 All rights reserved.Components Test/ResultsH.V. Transformer 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:■Primary winding: Less than 0.5 ohm (approximate)■Secondary winding: 120 ohms (approximate)■Filament winding: 0 ohms■Primary winding to grounding: Normal: Infinite■Filament winding to grounding: Normal: InfiniteMagnetron 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:■Filament terminal: Normal: Less than 1 ohm■Filament to chassis: Normal: InfiniteH.V. Capacitor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:■Terminal to terminal: Normal: Momentarily indicates several ohms and then gradually returns toinfinite.■Terminal to case: Normal: InfiniteH.V. Diode NOTE: Some inexpensive meters may indicate infinite resistance in both directions.1. Unplug microwave oven or disconnect power.2. Measure resistance:■Forward: Normal: Continuity■Reverse: Normal: InfiniteTurntable Motor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:■Normal: 2.4k to 3.2k ohms (approximate)Motor Capacitor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure motor capacitor:■Normal: Momentarily 0 ohms, then goes to infinite1. Unplug microwave oven or disconnect power.2. Remove the 4-pin connector from the cable.3. Measure resistance across pins 1 and 2.■Normal: 10k ohms +/-5% at 77°F (25°C)4. Measure capacity value across pins 3 and 4.■Normal: 180pF +/-5% at 55% RHHood Exhaust Fan Motor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:■High Speed—Normal: Red (RD) and Blue (BU) wires: 70 to 100 ohms (approximate); Blue (BU) andBlack (BK) wires: 30 to 60 ohms (approximate)■Low Speed—Normal: Red (RD) and Blue (BU) wires: 70 to 100 ohms (approximate); Blue (BU) andWhite (WH) wires: 50 to 80 ohms (approximate)HF NTC Thermistor 1. If “NTC SHORT, CALL FOR SERVICE” or “NTC OPEN, CALL FOR SERVICE” scrolls on display, unplugmicrowave oven or disconnect power.2. Measure resistance:■Normal: 10k ohms +/-5% at 77ºF (25ºC)Power Resistor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:■Normal: 65 ohms/65 WPrimaryFilament(orange/red wires)Secondary (whitewire - ground totransformer case)23Components Test/ResultsCooling Fan Motor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:■Normal: 40 to 60 ohms (approximate)AC Line Filter Board 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:■Normal: L-IN to L-OUT (coil): Less than 1 ohm; N-IN to N-OUT (coil): Less than 1 ohmThermostats NOTE: Refer to “Parts Layout” for opening and closing temperatures.1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure continuity:■Normal: ContinuitySCHEMATIC DIAGRAMCavity ThermostatMagnetron ThermostatCavityzH6V521/V21CAKey T ables for T est ModeKey Name Function Display BuzzerPopcorn-key 30 1 beepPotato orBaked Potato-key 31 1 beepVegetable-key 2E 1 beepFrozen Entrée-key 33 1 beepSteam Simmeror Steam Cook-key 2D 1 beepWarm Hold-key 06 1 beepReheat-key 24 1 beepDefrost-key 25 1 beepSoften/Melt-key 29 1 beepCook Time Humidity sensorcheckValue between2000 and 60001 beepCook Power RH NTC sensorcheckValue between10 and 401 beepCook key 07 1 beepTimer Set/Off-key 05 1 beepOptions/Clock HF NTC Thermistor XXX 1 beepStart or Software/Geeversion check*xx.xx.xx 1 beepAdd 30 Sec or +30Sec key 20 1 beepDinner Plate-key 32 1 beepBeverage-key 34 1 beepPizza-key 35 1 beep* Continuously pressing START or will respectively display SW Versionand Gee Version for each press.Key Name Function Display Buzzer1Cavity Light andCooling Fan OnCL 1 beep2Cavity Light, CoolingFan and Turntable OnCL TT 1 beep3-key 36 1 beep4-key 14 1 beep5-key 15 1 beep6Hood (Cooktop) LightOn (High)HL HIGH 1 beep7Hood (Cooktop) LightOn (Low)HL LOW 1 beep8Vent Fan On (HighSpeed)HF HIGH 1 beep9Vent Fan On (LowSpeed)HF LOW 1 beep0Microwave Oven(1000 W), CL, TT andCF On for 10 SecondsMW 1 beepLight or -key 03 1 beepTurntable -key 09 1 beepPOWER OUTPUT MEASUREMENTThe power output of the magnetron can be measured using the following“Voltage Measurement” and “Output Test” sections. Before you performthe test:■Make sure that the oven cavity is cool and clean.■Check the line voltage at the wall outlet while microwave oven isoperating. See the “Voltage Measurement at Power Source” section.T ools Needed■2-cup measuring cup■Thermometer■Voltmeter/ohmmeterVoltage Measurement at Power Source1. Fill the measuring cup with 2 cups (500 mL) of tap water.2. Place in the center of the microwave oven cavity.3. Operate the microwave oven on High speed for 1 minute.4. While the microwave oven is operating, measure the line voltage atthe power source. See “Measure Voltage” illustration.5. Verify the voltage is constant during microwave oven operation. Ifvoltage drops below 108V, contact a qualified electrician to checkyour electrical supply.6. Make note of the voltage while the microwave oven is running andproceed to the output test.Measure VoltageOutput T est1. Fill the measuring cup with 2 cups (500 mL) of 70ºF (21ºC) tap water.2. Stir the water with the thermometer to ensure uniform temperature.Add warm or cool water to bring the water to the correct temperature.3. Place the measuring cup in the center of the microwave oven cavity.4. Operate the microwave oven on High speed for 1 minute.5. Remove the measuring cup and stir the water with the thermometerfor about 20 seconds.6. Record the temperature of the water.7. Refer to the model serial tag on the microwave oven to acquirewattage output rating of the microwave oven.8. Using the following chart, determine if the output of the microwaveoven is within the range listed based on the line voltage and wattagerating of the microwave oven.Water Temperature for Line Voltage and Wattage RatingVoltage700 W1000 W1200 W120 V96ºF to 102ºF(36ºC to 39ºC)110ºF to 116ºF(43ºC to 47ºC)124ºF to 130ºF(51ºC to 54ºC)108 V91ºF to 97ºF(33ºC to 36ºC)101ºF to 107ºF(38ºC to 42ºC)111ºF to 117ºF(44ºC to 47ºC)COMPONENT TESTSAA. House power supply wall outletB. Voltmeter/Ohmmeter test leadsC. Microwave oven plugP ARTS LA YOUT (NOT TO SCALE)A. Line fuse (20 amp)B. AC line filter boardC. Hood fan motor assemblyD. Cavity lightE. Cavity light holderF. MagnetronG. Magnetron thermostat—opens at 257ºF (125ºC), closesat 185ºF (85ºC)H. Power resistorI. H.V. capacitorJ. H.V. diodeK. H.V. transformerL. Motor capacitorM. Cooling fan motorN. HF NTC thermistorO. ACUP. Touch panelQ. Secondary interlock switchR. Door interlock switchS. Monitor interlock switchT. Primary interlock switchU. Turntable motorV. Hood (cooktop) lightW. Hood (cooktop) light holderX. Cavity thermostat—opens at 257°F (125°C), non-resettableY. Humidity sensor ACUIMPORTANT:■Unplug microwave oven or disconnect power.■Discharge the high-voltage capacitor and remove thelead wires from the primary winding of the high-voltagetransformer before conducting any of the following tests.■Remove the lead wires from the related component beforeconducting any of the following tests.■All operational checks using microwave energy must be donewith the microwave oven loaded with a minimum of 8 oz(250 mL) of water in a microwave-safe container.■Conduct a microwave energy test after performing any testsor repairs to the microwave oven.■Check that all wire leads are in the correct positions beforeoperating the microwave oven.■Grasp wire connectors when removing the wire leads frommicrowave oven parts.■All testing must be done with an ohmmeter having asensitivity of 20,000 ohms per volt DC or greater andpowered by at least a 9 V battery.。
SuperPole™SuperBar™SuperTrapeze™SP-S SP-HDSPB-SSPB-HDSPB-AK(DC100 - RevE)STP-SSTP-AK89111012131457346212HW318HW323HW302202122232829301724252726182315181917163HW100SP102HW320HW300HW320HW112+++SP-SSPB-SSTP-SSP-SSPB-SSTP-SSP-HDSPB-HD12345 678910 42"/51mm6"/154mm3"/76mm10"/254mm ABC D EABCEDFACEBD45612351234 56 6HW318HW323HW30278910+(2-5)111271234HW100 56889101112HW100984"2134mm3+4567101289101111Ø 5" / 127mm 20"508mm93-99"2362-2515mm2.50" / 64mm1.0625" / 27mm8"203mm20"508mmØ 1.50" / 38.1mmFE / PVC / UHMW SP-P 13lbs / 5.9kgFE / NBR SP4034lbs / 1.8kgFE / NBR SP4021lbs / 0.4kg1216"406mm8"203mmØ 2.50"64mmØ 2"51mmØ 1.50"38.1mm3.875"98mm17"432mm8"203mm3-29"76-737mm12.25"311mm13.5"343mmPOMFEFE / PA / LDPE FE / PVC SP102.05lbs / .02kgFE / PVC SP4044.20lbs / 1.91kgSP4085.25lbs / 2.38kgSP411.85lbs / .39kgSP4092.05lbs / .93kgSUPERPOLE (SP-S)93-99"2362-2515mm 93-99"2362-2515mm 100-120"2540-3048mm 121-140"3073-3556mm < 93"2362mmSUPERBAR300lbs / 136kg450lbs / 205kg 300lbs / 136kg 300lbs / 136kg 300lbs / 136kgMAXANGLED CEILING PLATEUNI-FIT EXTENDERCEILING PLATE EXTENDERSUPER-TRAPEZESUPERPOLE HEAVY DUTY (SP-HD)UNI-FITEXTENDER (SP-UF)SUPERPOLEULTRA (SP-ULTRA)SUPERPOLE CUSTOM (SP-CUSTOM)SUPERPOLE CEILING PLATE EXTENDER (SP-CPE)SUPERPOLE ANGLED CEILING PLATE (SP-ACP)13OVERVIEWThank you for choosing the SuperPole System from HealthCraft. Please read and understand the instructions in this manual; keep manual for future reference. It is your responsibility to see that your SuperPole System is properly assembled, installed, and cared for. Failure to follow instructions in this manual could result in serious injury or death. If you are not equipped to undertake the outlined work, we would recommend that you have your SuperPole System installed by a qualified contractor.The SuperPole System is intended for moderate vertical load bearing to provide sitting and standing support for people with reduced mobility. The floor to ceiling range and maximum user weight dependent on model (see Page 13 for details and product / accessory compatibility chart). Product is not intended to support full body weight. The SuperPole System is not to be used in any other way than described above.The SuperPole is a high quality, commercial grade floor to ceiling safety pole. The SuperPole must be installed between a structural floor and ceiling by turning a jackscrew at the bottom of the pole. The pressure created by the jackscrew is strong enough for the SuperPole to support the user, yet it does not require drilling holes into the floor or ceiling. This is ideal for relocating or removing the pole. NOTE: The top plate has two holes that may be used to fix the plate directly to the ceiling joist if necessary. See Page 4 for details.The SuperBar is a high quality, commercial grade pivoting and locking horizontal bar that connects to the SuperPole (floor to ceiling safety pole). The horizontal bar can be lifted, pivoted and lowered to the next locking position around the SuperPole. In any of the 8 lowered position (every 45 degrees) the SuperBar can be used to support the user. It is important to set proper height and orientation of the SuperBar to optimize the user’s range of motion.The SuperTrapeze is a high quality, commercial grade over-bed trapeze that connects to the SuperPole (floor to ceiling safety pole). The SuperTrapeze handle features two offset ladder rungs to allow for improved use of arm strength and increased comfort. Additionally, it can hook around the pole to store out of the way when not in use. The support arm has an adjustable strap that attaches to the trapeze handle. It is important to set proper height and orientation of the SuperTrapeze to optimize the user’s range of motion.WARNING - PATIENT ENTRAPMENT (see additional guidelines)The potential risk of entrapment (limb, neck, head, torso) between the pole and adjacent item (i.e. bed, toilet, etc.) can be reduced or avoided by the following strategies:1. Situate the pole at a distance that is considerably smaller or larger than that which could result in entrapment.2. Consider situations that could change with time or usage such as mattress compression, patient movement, bed position changes due to electrically powered beds, etc.3. Realize that this product is not intended as a physical constraint or barrier to exiting the bed.LIMITED LIFETIME WARRANTYProducts are covered by a limited lifetime warranty against defects in materials and workmanship for the original purchaser. Warranty excludes products that have been damaged through misuse, accidental damage, alteration, normal wear and tear, wood material and stain, or the use of corrosive or abrasive cleaning products.Buyer hereby indemnifies, agrees to hold harmless and defend HealthCraft Products Inc. from and against any and all liabilities, claims, (founded and unfounded), losses, damages, costs and expenses (including without limitation consequential damages and reasonable professional fees) resulting from buyers specification, application, or improper use of goods described hereon; buyers omission or neglect. HealthCraft Products Inc. does not assume any liability for damage resulting from services performed by others or faulty installation, misuse or misapplication of goods sold by HealthCraft Products Inc. HealthCraft Products Inc. shall not be liable for prospective profits or special, indirect, or consequential damages, or for the cost of any corrective work done without HealthCraft Products Inc. prior approval. HealthCraft Products Inc. total liability hereunder shall in no event exceed the purchase price of the goods specified hereon. Specifications subject to change without notice.DELIVERY CONTENTS - SUPERPOLE FIGURE A.SP400 - POLE ASSEMBLY1. Pole2. Pole Grip, 20" length3. Cover Sleeve (with warning label)4. Threaded Collar5. Jam Nut6. Extension Screw7. Plastic WasherDELIVERY CONTENTS - SUPERBAR FIGURE B.SP404 - T-BAR ASSEMBLY15. T-Bar Weldment16. GripSP411 - COLLAR ASSEMBLY17. Spring Ring (with warning label)18. 5/16-24 Set Screw (x3)19. Castellated CollarSP403 - TOP PLATE ASSEMBLY8. Top Plate Rubber9. Top Plate10. Nylon Washer11. Cotter Pin12. Clevis PinSP402 - BASE PLATE ASSEMBLY13. Base Plate14. Base Plate RubberHARDWARE20. #8-32 Set Screw (x2)21. Pivot Bushing (x2)22. 3/32"Hex Key23. 5/32" Hex Key14DELIVERY CONTENTS - SUPERTRAPEZE FIGURE C. SP408 - SUPPORT ARM24. Support Arm Weldment25. Rectangular Plug26. Plastic Buckle27. Safety StrapSP409 - TRAPEZE ASSEMBLY28. Trapeze Handle29. Top Grip, 6" length30. Bottom Grip, 10" lengthINSTALLATION WARNINGS FIGURE D.1. Use caution while maneuvering pole during installation.2. Standard pole can be installed directly under 1 ceiling joist.3. Standard pole can be installed directly under 2 ceiling joists.4. Heavy Duty (HD) pole must be secured to ceiling joist (s).5. If subject to heavy usage, pole must be secured to ceiling joist (s).6. CAUTION - Damage may occur if extension screw is overtightened.7. CAUTION - Do not install if the structure above ceiling is unknown.8.CAUTION - Do not install on loose floor coverings.9. CAUTION - Do not install in rooms with radiant ceiling heat.10. CAUTION - Do not install on angled ceilings.SUPERPOLE PLACEMENT FIGURE E. 1. BEDROOM - Locate pole adjacent to waistline, and as close to bed as possible while allowing clearance for bed coverings.2. BATHTUB ONLY - Locate pole base against tub, approximately half way along its length3. SEATING (TOILET or CHAIR) - To provide clearance when standing, locate pole 3-10" / 76mm-254mm forward of the knees, and 2-6" /51mm-154mm to the side of knees when sitting.SUGGESTED SUPERBAR POSITIONS FIGURE E.4. BEDROOMA = side support / out of the wayB = in-bed supportC = sitting supportD = standing supportE = transfer support towalker / wheelchairSUPERPOLE INSTALLATION INSTRUCTIONS FIGURE F.1. On a flat horizontal surface, place top plate onto pole.2. Align holes and install clevis pin with washer on opposite side.3. Install cotter pin into clevis pin.4. Place base plate on floor at intended location, and tilt pole.5. When upright, install the pole into the base plate hole.6. Insert shaft of screwdriver thru drive hole of extension screw.7. Hold pole and turn screwdriver clockwise to raise pole.8. Top plate must contact ceiling squarely.9. Continue turning extension screw approx 2-5 turns until pole is secure.10. Turn jam nut until it is tight against bottom of pole.11. Turn both jam nut and extension screw together to jam tight.12. Remove screwdriver and lower cover sleeve to conceal screw.SUPERBAR INSTALLATION INSTRUCTIONS FIGURE G.1. Slide spring ring upwards on castellated collar to expose 3 set screws.2. Back off 3 cone point set screws with hex key so castellated collar canslide onto pole without set screws contacting pole.3. Install pivot bushing into T-bar assembly.4. Align hole and install screw with hex key.5. Remove cover sleeve from bottom of pole.6. Slide items onto bottom of pole (note order and orientation): T-Barassembly with installed pivot bushing top/first, spring ring withcastellated collar, pivot bushing and cover sleeve.7. Install SuperPole as per instructions Page 6-7.8. Install castellated collar to pole by tightening 3 set screws with hex key.The set screws MUST be tightened until the back of the screw is flushwith the collar or injury may result.9. Slide spring ring downwards on the castellated collar to retain set screws.10. Lower T-bar assembly onto castellated collar.11. Install bottom pivot bushing into T-bar assembly.12. Align hole and install screw with hex key.SUPERTRAPEZE INSTALLATION INSTRUCTIONS FIGURE H.1. Slide support arm onto top of pole with strap hook facing towards grip.Rest support arm on top of grip.2. Install SuperPole as per instructions Page 6-7.3. Rotate support arm over bed.4. Hold the trapeze handle under the support arm, such that the shorter rail of the handle is closest to the head of the bed.5. Rotate the strap 180° and slide onto the shorter rail of the trapezehandle until it reaches the top bend of the trapeze.6. Position support arm such that the trapeze handle hangs directly overthe user’s hands (on thighs) when they lay on the bed.7. Raise support arm approx 84"/2134mm from floor to top of support arm.8. Slide spring ring upwards on support arm to expose threaded holes.9. Install support arm to pole by tightening 3 set screws with hex key. Theset screws MUST be tightened until the back of the screw is flush withthe collar or injury may result.10. Slide spring ring downwards on the castellated collar to retain set screws.11. Adjust length of strap such that the user can comfortably grasp thebottom rail of the trapeze handle when laying down.TECHNICAL DATASee Figure I.PRODUCT COMPATIBILITY CHARTSee Figure J.PRODUCT USAGESee Figure I.HARDWARE18. 5/16-24 Set Screw (x4)23. 5/32" Hex Key5.BATHROOM or6.SITTINGA = side support / out of the wayB = standing or transfer supportC = standing supportD = standing or transfer supportE = standing or transfer supportF = transfer support in/out of bathtub1520。
双王子冰箱bd-93使用说明书那是冬天温度补偿开关,当冬天使用冰箱时,切换次开关。
其他功能:1、锁定/解锁非锁定状态下,同时按下冷冻调节和人工智慧键3秒,锁定图标显示,进入锁定状态。
锁定情况下,同时按下冷冻调节和人工智慧键3秒,锁定图标消失,锁定解锁,可进行以下各种设置。
2、人工智慧(如果您选择人为调节方式,此项可跳过)在环境温度波动较大时,人工智慧能确保冰箱自行正常工作。
冰箱根据环境温度的变化,自动调节温度设定,不再需要人为调节。
按下人工智慧键持续3秒,人工智慧图标显示,进入人工智慧状态。
如果人为退出该状态,在解锁状态下按下人工智慧键持续3秒,人工智慧图标消失即可。
人工智慧状态下,不能进行冷藏、冷冻温度调节或速冻设置,但可以进行变温室温度调节。
如果按下冷藏温度调节按键或冷冻温度调节按键,人工智慧图标闪烁3下,提示目前处于人工智慧状态。
3、假日功能锁定状态下,按下人工智慧键持续3秒,假日功能图标显示,进入假日功能,冰箱按设定运行;冷藏室会渐变到17℃,如要人为退出该状态,则在锁定状态下按下人工智慧键持续3秒,假日功能图标消失即可。
在人工智慧、冷藏关闭或速冻状态下,不能进入假日功能。
4、冷藏室温度调节(2-10℃)(含开关冷藏室)(如果您选择人工智慧方式,此项可跳过)按一下冷藏调节键,冷藏温度图标闪烁,进入冷藏室温度设定状态。
随后每按一下冷藏调节键,温度数值增加1℃,直到10℃。
再按该键,冷藏温度显示“OF”,进入预制关闭冷藏室功能;再按该键,温度数值回到2℃,如此循环;若设定后5秒内没有按键操作、或者立即进行其它按键操作,则冷藏温度显示区域停止闪烁并确定,冷藏温度显示出冷藏室的平均温度值或显示“OF”图标。
当选择“OF”档位并确定后,关闭冷藏室,当选择非“OF”档位并确定后,冷藏室恢复制冷。
5、变温室温度调节(10~-7℃)(含开关变温室)按一下变温调节键,变温室温度图标闪烁,进入变温室温度设定状态。
DC PANEL CONNECTORS for 39All connectors to be female pins with male connectors.11/21/2008 PLUG #1WIRE# (HULL)WIRED TO ON PANEL CONN. TYPE 1#51, 12ga Brown, WATER PUMP WATER PUMP BREAKER Deutsch -2#86, 10ga Brown/Pink, HEAD HEAD RESET DTP Series - 4pin 3#88, 12ga Brown/Yellow, SUMP PUMP SUMP PUMP RESET4#109, 10ga Brown/White, MACERATOR MACERATOR TOGGLE SWITCHPLUG #2WIRE# (HULL)WIRED TO ON PANEL CONN. TYPE 1#27, 12ga Tan, BILGE POWER BILGE TOGGLE SWITCH Deutsch -2#36, 12ga Brown/Red, BILGE MANUAL BILGE TOGGLE SWITCH DTP Series - 4 pin 3#37, 10ga Red/White, FREEZER REFRIGERATION BREAKER4#63, 10ga Red/Black, REFRIGERATOR REFRIGERATION BREAKERPLUG #3WIRE# (HULL)WIRED TO ON PANEL CONN. TYPE 1#42, 10ga Blue, MAIN LIGHTS CABIN LIGHT RESET #1Deutsch -2#55, 14ga Red, 12V OUTLET12V OUTLET RESET DTP Series - 4pin 3#84, 14ga Red, 12V OUTLET12V OUTLET RESET4#111, 14ga Red, 12V OUTLET12V OUTLET RESETPLUG #4WIRE# (HULL)WIRED TO ON PANEL CONN. TYPE 1#28, 16ga Red/White, START BATT TEST BATTERY VOLT TEST SWITCH Deutsch -2#73, 16ga Blue/White, ENG BOX LIGHT CABIN LIGHT RESET #1DT Series - 4pin 3#96, 16ga Blue/White, CHART LIGHT CABIN LIGHT RESET #14#120, 16ga Gray/White, BOW LIGHT RUNNING LIGHTS BREAKERPLUG #5WIRE# (DECK)WIRED TO ON PANEL CONN. TYPE 1#258, 14ga Gray/Red, ANCHOR LIGHT ANCHOR LIGHT SWITCH Deutsch -2#259, 14ga Gray/Green, STEAMING LIGHT STEAMING LIGHT SWITCH DT Series - 4pin 3#260, 14ga Gray/Red, ANCHOR LIGHT ANCHOR LIGHT SWITCH4#210, 14ga Gray/Yellow, STERN LIGHT RUNNING LIGHTS BREAKERPLUG #6WIRE# (DECK)WIRED TO ON PANEL CONN. TYPE 1#203, 14ga Blue, CABIN LIGHTS CABIN LIGHT RESET #2Deutsch -2#235, 14ga Blue, CABIN LIGHTS CABIN LIGHT RESET #1DT Series - 4pin 3#237, 14ga Blue, CABIN LIGHTS CABIN LIGHT RESET #24#246, 14ga Blue, CABIN LIGHTS CABIN LIGHT RESET #2WIRE# (PANEL TO PANEL)WIRED TO ON PANEL16ga Blue, PANEL LIGHTS PANEL LIGHT SWITCH16ga Yellow, PANEL LIGHTS (-)DC NEGATIVE BUS1。
P ortable b attery H ydraulic c utting u nits r adio c ontrolled B68RC3-85B68RC3-96B68RC3-120designed for remote cutting oPerations in man-Holesremote oPeration for smarter and safer workingOperating features:• 20 meters radio control operating range• Intelligent auto-return at the end of the cycle (Smart Release)• OLED multifunctional display with touch button • Electronic Pressure Sensor (EPS)• SMARTOOL technology for viewing and downloading operational data • Wireless blade sensor (no batteries)• Double acting with radio control or manual intervention • Pressure release button• Audible and visual indication of operational progress, completion and alarms • Anatomical shaping for more convenient and practical handling • Li-Ion 18.0 V-7Ah rechargeable high capacity battery • Automatic battery connection system with release buttonsignals that its blades have trav-elled fully.At this point the LED indicator and buzzer notify the operator of the successful completion of the cut-ting operation. For this reason, each pump is paired to its specific cutting head only and it must be considered as a complete unit.The heart of each unit is the new port-able pump B68M-P18-KV-RC3, bat-tery operated for independent use. Having the inherent strengths of the Cembre 18V tool range, the B68M-P18-KV-RC3 is a lightweight high capacity pump equipped with an in-novative radio remote control designed specifically for man-hole environments to allow operators to control and oper-ate the pump out of the man-hole at a safe distance.New Li-Ion 18V 7Ah batteries provide high c apacity w hile i mproved o perating speed results from a revitalized hydrau-lic system with double speed action. A maximum pressure sensor assures greater precision and repeatability of the pressure cycle, while a security valve doubles the provision for opera-tor safety.The u nit i s f itted w ith a p at-ented unique system for stopping the pump when the cutting head sensorThe unit has a manual pressure release button in case of emergency. Easy ac-cess to the oil reservoir is by means of an oil top-up inlet. The innovative remote control function is able to work in man-hole environment where radio commu-nication is normally more complicated. The unit features an OLED display to provide essential real time tool operat-N e w p o r t a b l e b a t t e r y h y d r a u l i c p u m p r a d i o c o n t r o l l e dLED indicators and buzzerPressure release buttonOLED multifunctional displayAutomatic battery connection system ing information including:- Operating mode selection (cutting or crimping)- Release mode selection (Smart re-lease, manual release)- Minimum set pressure and momen-tary pressure reached in bar/psi to allow verification of correct operation - Battery charge level - No. of cycles performed- No. of cycles before scheduled recom-mended maintenance - Motor temperature- Operating c ommand (radio o r m anual).The unit has a secondary operating trig-ger w hich c an b e s elected t hrough t he OLED display in case of need.B68M-P18-KV-RC3Data recording and intelli-gent control allow complete verification of operational parametersCEMBRE PROTECTUS, THE NAME FOR SAFETYNe w H y d r a u l i c C u t t i n g U n i t s R a d i o C o n t r o l l e d B68R C3S e r i e sB68RC3-85B68RC3-96B68RC3-120I n n o v a t i o n f i r s t a n d f o r e m o s t,i t’s i nElectronic Cut SensorT he ECS guarantees the precision of the cutting operation, checking the actual value of pressure and informing the operator about pos-sible errors.The operator is in full control of the pump at all times as the B68M-P18-KV-RC3 communicates the progress of the cutting operation by audible and visual indicators. All at a safe distance.The pump is equipped with intel- Radio Remote ControlT he B68M-P18-KV-RC3 pump in-troduces radio control to utilitycable cutting operations in limitedaccess locations, eg. in man-holes,to enable working from a safe dis-tance.Safe Cut TechnologyFitted with LED indicators and abuzzer to communicate duringprogress and at the completion ofthe cutting operation.E x a m p l e s o f u s e o f t h e u n i t sFitted by dielectric oil for operatorprotection in case of cutting cablesthat may be accidentally live.Each radio remote control is pairedto only its specific pump.Designed with improved handlingcharacteristics for convenience andmanagabiilty, B68M-P18-KV-RC3has a fibreglass-plastic shell withhigh resistance to wear and dam-age.Selecting the SMAR T RELEASEmode on the OLED display allowsthe operating pressure to be main-tained until the operating button isreleased, thus allowing blades toopen automatically at the end ofthe cutting cycle.When used in crimping mode thisfeature allows the operator to makea visual check of the crimped con-nection.SMARTOOL technology enables theuser to to store data from up to200,000 cycles on the integratedmemory card for transfer to a com-puter via a USB cable.The pump is also recommended foruse with Cembre KV type protectedcrimping heads.General features:TypeOperatingpressure bar Radio remote controlDimensions Pump mm Weight Pump kg (with Battery)Dimensions Heads mm frequency GHzoperatingrange meterslengthheightwidthlengthheightwidthB68RC3-857292,4204172362126,2409174140B68RC3-96498249147B68RC3-120536223140Supplied with:• Radio remote control (2405 ÷ 2480 MHz)• CB 1870L , Li-Ion 18.0 V 7.0 A h Battery (2 pcs)• ASC 30-36 EU 27044000, Battery charger(INPUT 220-240 V / 50-60 Hz; OUTPUT 12-42 V DC / 3.0 A MAX.)• USB cable • Shoulder strap• VAL-B68RC3 Metal Carring CaseCB 1870L 18 V - 7.0 Ah Li-Ion High Capacity Battery:•Equipped with LED indicators to show the remaining battery life at any time by pressing Provides 100 % of its energy between -15 and +50°CElectronic control of the individual cells to avoid under or overchargingAIR COOLED ventilated charging technology for a longer life and shorter recharge time N e w18VCembre Ltd.Tel.: +44 01675 470440 Fax: +44 01675 E-mail:***************.uk Cembre S.p.A.Telefono: +39 030 36921Telefax: +39 030 3365766www.cembre.itE-mail:****************Cembre S.a.r.l.Tél.: +33 01 60 49 11 90 Fax: +33 01 60 49 29 10www.cembre.frCembre España S.L.U.Teléfono: +34 91 4852580 Telefax: +34 91 4852581www.cembre.esE-mail:*******************Cembre GmbHTelefon: +49 089 3580676Telefax: +49 089 35806777www.cembre.deE-mail:***************Cembre Inc.Tel.: +1 732 225-7415Fax: +1 732 E-mail:**********************EK500PCVB-031EK100• CVB-031 Canvas bag• EK100 Earth cable for the pump (1 m length)• EK500P Earth cable for the head (5 m length) with earth rod and canvas bagA c c e s s o r i e s A v。
American Specialties, Inc. | 441 Saw Mill River Road, Yonkers, NY 10701 | (914) 476-9000 | Model:#0192-1-93Issued:11/1/2021Revised:8/22/2023Page:1 of 2Revision :R2/leedTURBO-Swift™ High-Speed ADA Hand – Satin Stainless Steel279Toilet Accessories CSI:10 28 13o Peration & M aintenancet echnical i nForMation / P roduct P roPertiesi nstallationo Ptionsw arrantySurface mount unit on wall with four (4) #10 x 1-3/16" [M5x36] self-threading Phillips pan-head screws and washers (supplied) through dryer chassis holes (provided) into suitable prepared mountings (by others) or other suitable mounting hardware (by others) to suit wall conditions. Electrical service is supplied and connected (by others) prior to installing cover. Cover is secured to back plate with recessed hex-socket flat-head screws (supplied) on sides. For compliance with 2010 ADA Accessibility Standards, 2015 ABA Standards and ICC/ ANSI A-117.1-2003 for adults install unit with bottom of sensor lens 48" [1219] maximum Above Finished Floor (AFF) if unobstructed reach access is provided or 44" [1118] max AFF if forward reach over an obstruction (e.g. vanity or commode) with reach depth greater than 20" [508] and less than 25" [635] is only provided. For general utility install unit so that sensor lens is 44" [1118] to 54" [1372] AFF . Mounting Template (MT) is supplied with unit with OM & IG and mounting heights for other age groups are shown on MT .Voltage0192-1-93: 110-120 VAC - 60 Hz - 8.3-9.1 A - 1000WMotorHPRPM (x1000)AirflowHeating Element Air Output T emperatureTimingDrying TimeN/ABrush T ype Dual Ball Bearings0.83082.4 CFM (140m3/h)Nichrome wire with auto reset circuit breaker104o F ± 5@77o F (40o C ±2.4 @ 25o C) Ambient room tempAutomatic 60second Shut-Off Less T han12 Seconds N/AManufacturer reserves the right to make changes to the design, dimensions or functionality of the product without formal notice.Automatic "No-Touch"Activate dryer by placing hands under sensor. The activation will turn on a blue LED light to guide user to the air flow. Dryer automatically shuts off after user removes hands from sensor zone. Complete OM & IG and MT are supplied with unit for future reference of Installation Requirements, Operating Conditions and Service.One (1) Y ear from date of InvoiceAmerican Specialties, Inc. | 441 Saw Mill River Road, Yonkers, NY 10701 | (914) 476-9000 | Model:CSI:#0192-1-9310 28 13Toilet Accessories Issued:11/1/2021Revised:8/22/2023Page:Revision :Type 304 Stainless Steel - Satin Finish 110-120V AC PropertyValueDimensions Construction 6-27/32" x 10-1/16" x 4" [174 x 256 x 102]Surface Mounted - "Touch Free" Operation 2 of 2R2Mounting Electrical。