RJ45可靠性试验项目、测试要求、判定标准、依据规范一览表保持力Plug retention 用20磅的轴向载荷,将带锁扣的插头以每分钟5英寸的速度插入,维持5秒的负荷。
Apply an axial load of 20 pounds to plug housing at a rate of .5inch per minute with plug mated in jack and latch engaged.Maintain load for 5 seconds.封闭型插座57.83N Min开口型插座30N Min,插头不脱出插口Closed socket 57.83n min, open socket30n min.Plug shall not dislodge fromjack.EIA-364-9810PASS振动试验Vibration 将产品包装好放入纸箱放在振动台上进行振动。
振动频率10~55HZ之间变化,振幅0.4英寸,10-55-10HZ为一个循环,3个相互垂直的轴向各扫频5次持续2小时Subject mated plug and terminated jack to frequency range of 10to 55Hz with displacement amplitude of .014 (0.356mm) inch. Sweepcycles per direction shall be 5 in each direction of 3 axis whichare mutually perpendicular planes for 2 hours .最大不得超过1微秒的信号瞬断,产品没有物料和特性伤害,插头高度5.89mm.No discontinuities of 1 microsecondmaximum. Shall remain mated and showno evidence of physical damage. Plugmust meet 5.89mm.EIA-364-2810PASS抗焊接热试验Resistance to soldering heattest 测试产品浸入焊内,260+10/0℃,5~10sThe test specimen immerge in tin,260+10/0℃,5~10s塑壳无熔化、变形现象Plastic without melting, deformationphenomenonsEIA-364-5610PASS温度冲击Thermal shock (-40 ℃与85 ℃)为一个循环,每个循环1个小时,共做5个循环。
RJ45集成磁性连接器的耐压特性说明及其测试原则性足够好,加在上面的电压就只会产生很小的漏电流。
如果一个被测设备绝缘体在规定的时间内,其漏电电流保持在规定的范围内,就可以确定这个被测设备可以在正常的运行条件下安全运行。
进行耐压测试时(如下图所示),技术规格不同的被测试品,测量标准也就不同。
对一般被测设备,耐压测试是测量火线与机壳之间的漏电流值。
测试系统有三大模块:程控电源模块、信号采集调理模块和计算机控制系统5.通用耐压测试程序介绍测试程序耐压测试(以华仪EXTECH7142为例:)程序设置及仪器操作方法详见《华仪EXTECH7142操作指南》5.1.1打开电源。
5.1.2 选择AC或DC耐压测试。
5.1.3设置测试电压值。
交流1500V 或直流2250V.5.1.4设置测试电流值。
最高测试电流限定值= 每个port交流1mA, 或所有port直流1mA.最低测试电流限定值= 交流, 或直流0mA.5.1.5 设置上升时间。
上升时间= 交流, 或直流5s.5.1.6 设置保持时间.保持时间=交流和直流60s。
5.1.7 设置电弧侦测功能。
电弧侦测灵敏度等级= 5关闭电弧侦测功能5.1.8 设置连续测试。
打开连接5.1.9用校准盒校验耐压机5.1.9.1连接方式Hi-pot tester(耐压机) Calibration Box(校准盒)HV Terminal(高压端子) /Return Terminal(低压返回端子) Ground(连续测试端子) AC/DC Continuity测试夹具仅5.1.9.2校验耐压机,所有测试应当提示不良。
当转到AC/DC fail 测试档时,耐压机器立即提示不良当转到AC/DC pass 测试档时,耐压机待电压爬升至,,或,时, 提示不良。
(Remove the High Voltage Test lead from the Hi-pot Test Failure box and retest. The Low level Failure will come on AC or DC)5.1.10耐压测试方法及连接首先,使用RJ45插头组(其终端被短接在一起)将产品的每个Port连接起来,然后再把它连接到耐压机的红色高压测试表笔。
3MHz and 30MHz.4.耐压测试原理及方框图4. 1 耐压测试原理:把一个高于正常工作的电压加在被测设备的绝缘体上,并持续一段规定的时间,如果其间的绝缘性足够好,加在上面的电压就只会产生很小的漏电流。
如果一个被测设备绝缘体在规定的时间内,其漏电电流保持在规定的范围内,就可以确定这个被测设备可以在正常的运行条件下安全运行。
进行耐压测试时(如下图所示),技术规格不同的被测试品,测量标准也就不同。
对一般被测设备,耐压测试是测量火线与机壳之间的漏电流值。
测试系统有三大模块:程控电源模块、信号采集调理模块和计算机控制系统5.通用耐压测试程序介绍测试程序耐压测试(以华仪EXTECH7142为例:)程序设置及仪器操作方法详见《华仪EXTECH7142操作指南》5.1.1打开电源。
5.1.2 选择AC或DC耐压测试。
5.1.3设置测试电压值。
交流1500V 或直流2250V.5.1.4设置测试电流值。
最高测试电流限定值 = 每个port交流1mA, 或所有port直流1mA.2 主审:饶利军(Lee Rao)编写人员:Karen Peng Fan Liang Zhi Lee Rao最低测试电流限定值 = 交流, 或直流0mA.5.1.5 设置上升时间。
上升时间 = 交流, 或直流5s.5.1.6 设置保持时间.保持时间=交流和直流60s。
5.1.7 设置电弧侦测功能。
电弧侦测灵敏度等级 = 5关闭电弧侦测功能5.1.8 设置连续测试。
打开连接5.1.9用校准盒校验耐压机5.1.9.1连接方式Hi-pot tester(耐压机) Calibration Box(校准盒)HV Terminal(高压端子) /Return Terminal(低压返回端子) Ground(连续测试端子) AC/DC Continuity测试夹具仅5.1.9.2校验耐压机,所有测试应当提示不良。
当转到AC/DC fail 测试档时,耐压机器立即提示不良当转到AC/DC pass 测试档时,耐压机待电压爬升至,,或,时, 提示不良。
技术文件技术文件名称:终端和家庭网关可靠性测试规范技术文件编号:版本:共57页(包括封面)拟制审核会签标准化批准修改记录目录1产品说明及试验类别 (5)2引用标准 (6)3试验项目 (7)3.1试验项目 (7)3.2样品要求 (8)3.3试验要求 (8)4测试配置 (9)5测试项目及指标要求 (11)6环境适应性试验 (12)6.1 低温冷启动 (12)6.2 低温工作 (13)6.3 高温开关电 (15)6.4 高温工作 (16)6.5 高低温循环 (18)6.6 交变湿热 (20)6.7 高温贮存 (21)6.8 低温贮存 (23)6.9 电源拉偏 (25)6.10 冲击试验(运行) (26)6.11 随机振动(运行) (27)6.12 正弦振动(运行) (28)6.13自由跌落(裸机) (29)6.14冲击试验(运输) (30)6.15 随机振动(运输) (31)6.16 自由跌落(运输) (32)6.17 随机振动(存储) (33)6.18 正弦振动(存储) (34)7EMC试验 (35)7.1传导骚扰 (35)7.2辐射骚扰 (36)7.3 静电抗扰 (38)7.4 辐射抗扰 (39)7.5 快速瞬变脉冲抗扰 (40)7.6 传导抗扰 (41)7.7 浪涌抗扰 (42)7.8 电力线感应 (44)7.9 电力线接触 (45)7.10 AC电源端口电压暂降以及短时中断 (46)8RF测试 (47)8.1 RF试验(2.4GHz) (47)8.2 RF试验(5GHz) (48)8.3 RF试验(DECT) (49)9安规试验 (51)9.1 温升测试 (51)9.2 通风孔堵塞测试 (53)9.3 通讯网络过电压保护测试 (54)9.4绝缘强度测试 (55)9.5 变压器的绝缘强度测试 (56)10热测试 (57)10.1 高温热测试 (57)11四角测试 (58)11.1 四角测试 (58)1 产品说明及试验类别DSL终端和家庭网关产品,包括ADSL终端产品、VDSL终端产品和网关系列产品。
网络连接器接触可靠性测试要求及设计总结【摘要】本文介绍了网络连接器在接触可靠性测试方面,业界和大厂的要求,就如何满足这些可靠性测试要求,在设计上关键点做一总结,让从事网络连接器设计者借鉴参考,避免在设计上走弯路。
【关键词】机械冲击;机械振动;摇摆测试;正向力;瞬断(discontinuity);可靠连接;连接器1.引言电子连接器是电子网络、电子设备、电子终端中完成电功率,电信号传输的精密组件,它的功能及整体质量好坏对系统影响极大。
连接接触可靠性是保证信号传输功能重要的环节,没有可靠的电子连接,就没有先进的电子学。
连接器最重要的功能要求是:将主板和接口设备能够进行可靠连接。
产品在客户端被抱怨的项目各种各样,但其中影响功能的缺陷最不能接受。
图1是机柜布线照片,我们可以看到网线被绑拽,这就对网口连接器母头接触可靠性方面提出更高的要求:包容公头,并能在恶劣状况下可靠连接,怎样才能从设计上保障?怎样测试确认?详见如下内容:图1 机柜布线和连接器公母头外形图图2 机械振动条件和机器图2.网口连接器接触可靠性测试介绍连接器信赖性测试包含机械性能测试,电性能测试,环境性能测试。
其中环境性能测试是考虑产品可靠性的方面,包含耐热性,耐冷性,冷热冲击,温湿循环,烟雾测试,插拔循环,耐焊接热,机械冲击,机械振动,混合气体等等。
针对很多信赖性测试项目,其前后均通过测试低功率接触阻抗项目来判断功能是否完好,其本质上也是考虑其接触性。
但机械振动和机械冲击是直接考虑接触可靠性,通过是否有信号瞬断来判断。
2.1 机械振动依据连接器测试标准:EIA364-28,测试条件:频率10赫兹~500赫兹~10赫兹,振幅1.5mm,测试时间:每个坐标系方向2小时,三个坐标系共计持续6小时,测试样品:母头和公头配合形成信号回路,加载100毫安电流,回路上串连瞬断显示器。
整个测试过程中测试样品不能发生机械损伤,电流信号保持持续畅通,出现电信号瞬断时间不得大于1微秒(百万分之一秒),否则判定不通过。
保持力Plug retention 用20磅的轴向载荷,将带锁扣的插头以每分钟5英寸的速度插入,维持5秒的负荷。
Apply an axial load of 20 pounds to plug housing at a rate of .5inch per minute with plug mated in jack and latch engaged.Maintain load for 5 seconds.封闭型插座57.83N Min开口型插座30N Min,插头不脱出插口Closed socket 57.83n min, open socket30n min.Plug shall not dislodge fromjack.EIA-364-9810PASS振动试验Vibration 将产品包装好放入纸箱放在振动台上进行振动。
振动频率10~55HZ之间变化,振幅0.4英寸,10-55-10HZ为一个循环,3个相互垂直的轴向各扫频5次持续2小时Subject mated plug and terminated jack to frequency range of 10to 55Hz with displacement amplitude of .014 (0.356mm) inch. Sweepcycles per direction shall be 5 in each direction of 3 axis whichare mutually perpendicular planes for 2 hours .最大不得超过1微秒的信号瞬断,产品没有物料和特性伤害,插头高度5.89mm.No discontinuities of 1 microsecondmaximum. Shall remain mated and showno evidence of physical damage. Plugmust meet 5.89mm.EIA-364-2810PASS抗焊接热试验Resistance to soldering heattest 测试产品浸入焊内,260+10/0℃,5~10sThe test specimen immerge in tin,260+10/0℃,5~10s塑壳无熔化、变形现象Plastic without melting, deformationphenomenonsEIA-364-5610PASS温度冲击Thermal shock (-40 ℃与85 ℃)为一个循环,每个循环1个小时,共做5个循环。
上海千测认证网提供无线通信设备测试规范1)半成品测试:在将POE、设备内部馈线、RJ-45插头以及其它半成品制作完毕以后,先观察半成品的制作是否良好,各个焊点是否有虚焊。
用万用表测试各点是否连接正常,网线连接是否良好,数据线以及电源线的连接是否正常。
测试完毕后,如发现问题及时补救并重新测试方能进入下一环节。
2)未封装的成品测试:成品制作完毕后,必须首先测试电源是否有短路方能进入带电测试。
按产品要求连接好成品后,接入电源。
检查成品的各指示灯是否正常。
(如电源指示灯不亮,则断电后检查电源模块以及成品的电源线路以及接头是否连接正常。
如数据灯或交换机指示灯不亮,断电后检查网线连接是否正常,RJ45插头是否插牢等。
)如指示灯正常便可通过计算机搜索设备。
(如不能找到则检查成品内部POE到模块之间的数据连接是否正常、RJ45插头是否插牢。
)在计算机上找到设备以后首先将默认的IP地址0,0,0,0修改为192,168,0,123。
然后进入管理界面查看是否能正常连接并修改设备配置。
将设备修改为网桥模式,利用软件测试设备的无线带宽(标准为4兆以上,底于该标准则测试不和格)。
将设备修改为AP模式,利用软件测试设备的无线带宽(标准为2兆以上,底于该标准则测试不合格。
测试设备在网桥点对点、点对多点、AP、AP-client模式下是否工作正常。
以及WEP加密、SNMP管理、信道变换、SSID加密等是否能正常运行。
3)封装成品测试:将通过未封装的测试的成品封装好以后再进行成品老化测试,将设备连续通电至少14小时以上,测试设备运行是否正常。
(每次老化测试可对10台设备同时进行测试)4)无线覆盖范围测试:将设备运到630厂外一条大约1公里的路上,将设备接入7db的车载天线。
测试人员手提笔记本站在设备标准最大覆盖范围的地方,测试是否能对设备进行有效连接。
如果可以则通过测试。
考虑到笔记本是用电池供电,每次测试可最多对20台设备进行测试注意事项:1、对设备进行带电测试时必须将天线接好,撤换设备配件或天线时不可带电操作。
网络连接器接触可靠性测试要求及设计总结【摘要】本文介绍了网络连接器在接触可靠性测试方面,业界和大厂的要求,就如何满足这些可靠性测试要求,在设计上关键点做一总结,让从事网络连接器设计者借鉴参考,避免在设计上走弯路。
【关键词】机械冲击;机械振动;摇摆测试;正向力;瞬断(discontinuity);可靠连接;连接器1.引言电子连接器是电子网络、电子设备、电子终端中完成电功率,电信号传输的精密组件,它的功能及整体质量好坏对系统影响极大。
连接接触可靠性是保证信号传输功能重要的环节,没有可靠的电子连接,就没有先进的电子学。
连接器最重要的功能要求是:将主板和接口设备能够进行可靠连接。
产品在客户端被抱怨的项目各种各样,但其中影响功能的缺陷最不能接受。
图1是机柜布线照片,我们可以看到网线被绑拽,这就对网口连接器母头接触可靠性方面提出更高的要求:包容公头,并能在恶劣状况下可靠连接,怎样才能从设计上保障?怎样测试确认?详见如下内容:图1 机柜布线和连接器公母头外形图图2 机械振动条件和机器图2.网口连接器接触可靠性测试介绍连接器信赖性测试包含机械性能测试,电性能测试,环境性能测试。
其中环境性能测试是考虑产品可靠性的方面,包含耐热性,耐冷性,冷热冲击,温湿循环,烟雾测试,插拔循环,耐焊接热,机械冲击,机械振动,混合气体等等。
针对很多信赖性测试项目,其前后均通过测试低功率接触阻抗项目来判断功能是否完好,其本质上也是考虑其接触性。
但机械振动和机械冲击是直接考虑接触可靠性,通过是否有信号瞬断来判断。
2.1 机械振动依据连接器测试标准:EIA364-28,测试条件:频率10赫兹~500赫兹~10赫兹,振幅1.5mm,测试时间:每个坐标系方向2小时,三个坐标系共计持续6小时,测试样品:母头和公头配合形成信号回路,加载100毫安电流,回路上串连瞬断显示器。
整个测试过程中测试样品不能发生机械损伤,电流信号保持持续畅通,出现电信号瞬断时间不得大于1微秒(百万分之一秒),否则判定不通过。
可靠性试验规范-试验方法目次1 范围 (1)2 术语和定义 (1)2.1实验室环境(Laboratory environment) (1)3 试验项目 (1)3.1 A组环境可靠性试验 (1)3.2 B组结构可靠性试验 (10)4 记录 (17)附录 A 外观检查项目 (18)附录 B 功能检查项目 (19)附录 C 射频检查项目 (20)图表目录表1 外观检查项目 (18)表2 功能检查项目 (19)表3 射频指标检查项目 (20)可靠性试验规范-试验方法1 范围2 术语和定义2.1 实验室环境(Laboratory environment)温度T = 20 – 25 ℃,相对湿度RH = 40 – 60 %。
3 试验项目3.1 A组环境可靠性试验3.1.1 气候环境试验3.1.1.1 低温运行a)试验目的:验证样品在低温环境下使用的适应性。
b)试验参数:1)温度要求:-30℃(CDMA手机,Gota产品,车载产品);-20℃(便携式手机);-10℃(网卡、接入盒、固定台、监视终端);2)持续时间:16H(温度稳定后开始计算);3)电压拉偏:在开机电压下进行试验(如在3.5 V 进行电压拉偏试验);4)测试样机数:不小于5台。
c)测试设备:综合测试仪,温度试验箱d)试验步骤:1)在室温下检查待测试验样机的结构,外观及电性能。
2)将待测样机放进温度试验箱,连接好充电器,开机,样机处于充电待机状态。
3)温度试验箱内温度以1℃/min的速率从常温下降到设定的温度。
4)温度达到稳定后持续运行4小时,对试验样机进行在线射频监测。
量测时,样机不应从试验箱中取出。
5)接着,使样机的处于开机电压(例如3.5 V)下进行电压拉偏试验,拉偏作用时间为4小时,然后对样机的射频性能按附录B进行测试。
量测完成后,温度试验箱内温度以1℃/min的速率从低温恢复到常温。
3.1.1.1.1 例图1:低温运行曲线6)将样机从箱内拿出来立即按附录A和附录B进行外观功能测试。
一、電壓測試
1.依圖連接線路
2.設定電源供應器輸入:48Vdc Tye
3.設定電子負載:CC Mode 0.35A
1.LED-1
2.LED-2
3.電源供應器輸入電流
4.電子負載電壓值
亮燈亮燈
0.4A Max 48Vdc ±10%
電源供應器(TOP 6603D) 電子負載
(Chroma 63010) ETU-1305 LF Terminal Unit
二、LINK 測試 1.確認測試環境正常
2.依圖連接線路
RJ45 Cable 25m RJ45 Cable 25m
100 base Link pass 100 base Link pass
PC-1 PC-2
二、電壓測試接線:
三、LINK 測試接線:
一、電壓測試
1.依圖連接線路
2.設定電源供應器輸入:
48Vdc Tye 3.設定電子負載:CC Mode 2.0A
1.LED-3
2.電源供應器輸入電流
3.電子負載電壓值
亮燈
0.35A Max 5Vdc ±2%
電源供應器(TOP 6603D) 電子負載(Chroma 63010) PA-1305 LF DC/DC CONVERTER
二、LINK 測試 1.確認測試環境正常
2.依圖連接線路
RJ45 Cable 25m RJ45 Cable 25m
100 base Link pass 100 base Link pass
PC-1 PC-2
二、電壓測試接線:
三、LINK 測試接線:。