SRS1620_1中文资料
- 格式:pdf
- 大小:159.25 KB
- 文档页数:2
Dimensions in inches and (millimeters)Version: C07SRS1620 - SRS1615016.0 AMPS. Surface Mount Schottky Barrier RectifiersD 2PAKFeaturesFor surface mounted application Low forward voltage drop High current capability High reliabilityHigh surge current capabilityMechanical DataCases: D 2PAK molded plasticEpoxy: UL 94V-0 rate flame retardant Terminals: Pure tin plated, lead free.solderable per MIL-STD-202, Method 208 guaranteedPolarity: As markedHigh temperature soldering guaranteed:260oC/10 seconds at terminals Weight: 1.70 gramsMaximum Ratings and Electrical CharacteristicsRating at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%Type NumberSymbol SRS 1620 SRS 1630SRS 1640 SRS 1650 SRS1660 SRS 1690 SRS 16100 SRS 16150Units Maximum Recurrent Peak Reverse Voltage V RRM20 304050 60 90 100150V Maximum RMS Voltage V RMS 14 212835 42 63 70 105V Maximum DC Blocking Voltage V DC 20 304050 60 90 10 150V Maximum Average Forward RectifiedCurrent See Fig. 1I (AV) 16 A Peak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC method )I FSM 150AMaximum Instantaneous Forward Voltage@8.0AV F 0.55 0.70 0.90 1.00 V 0.5 0.1 Maximum D.C. Reverse Current @ Tc=25 oC at Rated DC Blocking Voltage @ Tc=100 oCI R 15 10 5.0mAmA Typical Junction Capacitance (Note 2) Cj700 460 320 pFTypical Thermal Resistance (Note 1) R θJC 2.0oC/W Operating Junction Temperature RangeT J -65 to +125-65 to +150o C Storage Temperature Range T STG-65 to +150 o CNotes: 1. Thermal Resistance from Junction to Case Per Leg2. Measured at 1MHz and Applied Reverse Voltage of 4.0V D.C.RATINGS AND CHARACTERISTIC CURVES (SRS1620 THRU SRS16150)FIG.2- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER LEGP E A K F O R W A R D S U R G E C U R R E N T . (A )125102010050 050200150100250300NUMBER OF CYCLES AT 60HzFIG.1- MAXIMUM FORWARD CURRENT DERATI NG CURVEA V E R A G E F O R W A R D C U R R E N T . (A )oCASE TEMPERATURE. (C)Version: C07FIG.4- TYPICAL REVERSE CHARACTERISTICSI N S T A N T A N E O U S R E V E R S E C U R R E N T . (m A )204060801001201401.010PERCENT OF RATED PEAK REVERSE VOLT AGE. (%)FIG.6- TYPICAL TRANSIENT THERMAL CHARACTERISTICSO T R A N S I E N T T H E R M A L I M P E D A N C E . (C /W )10.010.1101000.1101100PULSE DURATION. (sec)FIG.5- TYPICAL JUNCTION CAPACIT ANCE PER LEGC A P A C I T A N C E .(p F )200400800REVERSE VOLTAGE. (V)FIG.3- TYPICAL FORWARD CHARACTERISTICS I N S T A N T A N E O U S F O R W A R D C U R R E N T . (A )INSTANTANEOUS FORW ARD VOLTAGE. (V)。
PRODUCT FEATUREoMulti-input and multi-range performanceo Small instrument depths (62 mm–65 mm) save space, thus securing a larger installation area.o Large 13.8 mm bright display (SRS1 & SRS4), 21.8 mm (SRS3) & 22mm (SRS5)o 1 Pattern, 10 step program function available (option)n DisplayDigital display:Measured value (PV):7-segment red LED, 4 digitsTarget set value (SV):7-segment green LED, 4 digitsSRS1 PV height of character: Approx. 13.8mm/ SV height of character: Approx. 10.65mmSRS3 PV height of character:Approx. 21.8mm/ SV height of character: Approx. 14.6mmSRS4 PV height of character:Approx. 13.8mm/ SV height of character: Approx. 10.65mmSRS5 PV height of character:Approx. 22.0mm/ SV height of character: Approx. 10.6mmAction display: LED lamp display: ColorAuto tuning (AT): Lights during standby (flashes during execution): GreenAction display (RUN): Lights during fixed value control operation (FIX):GreenFlashes during program RUN program control operation (RUN):Green Control output (OUT): Lights during contact or SSR drive voltage output: GreenFor voltage/current output, lights when output is 100%In other cases, flashes at intervals of 0.5 sec. (multiples of 0.5 sec.).Manual control output (MAN): Flashes during manual output is ON: GreenEvent (EV1, EV2):Lights during event output: OrangeDisplay resolution:Differs according to input range (0.001, 0.01, 0.1, 1)Display accuracy:TC: ±(0.3%FS + 1 digit + 2 °C)Pt: ±(0.3%FS + 1 digit + 0.1 °C)mV: ±(0.3%FS + 1 digit)V: ±(0.3%FS + 1 digit)Display accuracy maintainingrange:23 °C±5 °CMeasured value display range:-10–110% of measuring range (not below -273.15 °C : T/C input) -10–110% of measuring range (not below -240 °C : RTD input)Display cycle:500 ms (0.5 seconds)n SettingSetting method:Target value setting range:Same as measuring range (within setting limiter)Setting limiter:Individual setting for higher & lower limits are possibleWithin measuring range (lower limit value < higher limit value)Setting lock:OFF, 3-stage setting (1-3)n Input● Input common specificationinput type:Multi range input (T/C, RTD, mV, V)● Input scaling:Settable within measurement range, span 10 digits or more● Display scaling Settable at voltage input (mV, V)Scaling range-1999–9999 digitSpan 10–9999 digit● Thermocouple input (TC)Input type:B, R, S, K, E, J, T, N, PL ll, C (WRe 5-26), AuFe-Cr, {U, L (DIN43710) }Display range:Within PV limiter (provided that minimum temperature does not fall below -273.15 °C)With or without a decimal point is selectable.Input resistance:500kΩExternal resistancetolerable range:100Ω or belowCold junctioncompensation:InternalInternal cold junctioncompensation accuracy:±2°C (5–45°C)Burnout function:Only upscale● Resistance temperaturedetector input (RTD):Pt100 Three-wire typeDisplay range:Within input range setting (provided that minimum temperature does not fall below -240°C)With or without a decimal point is selectable.Lead wire tolerableresistance range:Below 10Ω/1 wire (All wires should have the same resistance.)Amperage:Approx. 0.25 mA (All wires should have the same resistance.)● Voltage input (mV)Input type:-10–50 mV DCDisplay:Programming scaling (Within PV limiter, rounded off to the lowest displayed place from the next lower place.) Input resistance:Approx. 500kΩ or aboveScaling:Valid when voltage inputScaling range:-1999–9999 digitSpan:10–9999 digitDecimal point position:Without, settable from 0.1, 0.01, or 0.001Sampling cycle:0.5 secondsPV bias:-1999–2000 digitsPV ramp:0.500–1.500 times input valuePV filter:OFF, 1–100 sec.Scaleover display:LLLL, HHHHIsolation:Uninsulated from system and DI, but insulated from other inputn Control modeExpert PID control with auto-tuning function● Control outputContact (Y):Contact (1a), 240V AC, 2.5 A: Resistive load/1 A: Inductive loadSSR drive voltage (P):12 V ± 1.5 V DC (max. load current 20 mA)Current (I):4–20 mA, max. load resistance 600ΩVoltage (V):0–10 V, max. current 2 mAOutput resolution:0.01% (1/10000 )No. of SV:2No. of PID: 2 classesProportional band:OFF, 0.1–999.9% (ON-OFF action when OFF)Integral time:OFF, 1–6000 sec. (P or PD action when OFF)Derivative time:OFF, 1–3600 sec. (P or PI action when OFF)Target value function:OFF, 0.01–1.00Output limiter:Lower limit0.0%–99.9%, higher limit 0.1–100.0% (lower limit value < Higher limit value)Manual reset:-50.0–50.0% (Valid when I = OFF)ON-OFF hysteresis:1–999 digits (Valid when P = OFF)Proportional cycle:1–120 sec., 1 sec. stepControl outputcharacteristics:Reverse/direct selectable● Manual controlOutput setting range:0.0–100.0 %, 0.1% stepOutput update cycle:500 ms (0.5 sec.)Manual n auto tuning:Balanceless/bumpless action (switch through front panel key switch or external control input [DI])n Event output (EV)No. of output:Standard 2 points (EV1-EV2)Constant rating:Contact (1a), 240 V AC, 1 A: Resistive load (common)Function:Display:ActionHd:Higher limit deviation value actionLd:Lower limit deviation value actionod:Outside higher/lower limit deviation actionid:Inside higher/lower limit deviation actionHA:Higher limit absolute value actionLA:Lower limit absolute value actionSO:Scale overRUN:Control executionROT1:Control output inverted output (contact output only)STPS:Step signalPTNS:Pattern signalENDS:Program end signalHOLD:Hold signalPROG:Program signalU_SL:Upslope signalD_SL:Downslope signalGUA:Guarantee soak● Setting rangeAbsolute value:Within both measuring range and PV limiter (both higher and lower limit) Deviation:-1999–2000 digits (both higher and lower limit)Higher/lower deviation:0–2000 digits (both inside and outside)Action:ON-OFF actionHysteresis:1–999 digitsAction delay time:OFF, 1–9999 sec.Standby action:Separate setting (separate output), selectable from any of 4 types below1) Without2) Standby 1 (when starting power, when RST ON g OFF)3) Standby 2 (when starting power, when RST ON g OFF, when execution SV is changed)4) Standby 3 (Does not output when there is input abnormality.)Latching:Selection from ON/OFFOutput characteristics:Selection from NO/NCOutput update cycle:500 ms (0.5 sec.)Isolation:Insulated from all input and output (uninsulated within EV)n External control input (DI)● No. of input:Standard 1 point● Input type:Level input, edge input● Input rating:Voltage 5 V DC (2.5 mA/1 input)● Input action:Non-voltage contact or open collector● Input holding time:500 ms (0.5 sec.)● Function:Display:Action:NON No selectionRUN1:Starts control when ON: LevelRUN2:Starts control when ON: EdgeMAN:Manual control output mode: LevelAT:AT execution: EdgeSV:SV switch:RAMP:Ramp halt:ACT:Output characteristics: LevelL_RS:Event latching release: EdgePROG:Program switch: LevelHLD:Hold signal:ADV:Advance signal: Edge● Isolation:Uninsluated from input and system, but insulated with othern Program (option)● No. of pattern:1● No. of step:10● Power failurecompensation:Without● Guarantee soak zone:oFF, 1–999 digits● Standard mode:Start SV value/PV value Selectable● No. of pattern execution:1–9999● Time accuracy:Set value × 0.3%n General specifications Data storage:By non-volatile memory (EEPROM)● Operating ambient Ambient temperature:-10–50 °CHumidity range:Below 90%RH (no condensation)Storage temperature:-20–65 °C Over voltage category:IIElevation:Max. 2000 m Pollution class: 2 (IEC 60664)Supply voltage:100–240 V AC ± 10% (50/60 Hz)● Power consumption:10 VA● Input noise removal ratio:Normal mode: 50 dB or above (50/60 Hz)● Common mode:120 dB or above (50/60 Hz)● Applicable standard:Safety: IEC61010-1 and EN61010-1 IEC61010-2-030 and EN61010-2-030EMC: EN61326-1RoHS: EN50581● Power supply short-break time:Within 50 ms, normal action continuation (when 200V)● Insulation resistance:Input-output terminal and power terminal interval, 500 V DC, 20MΩ or above ● Dielectric strength:Input-output terminal and power terminal interval, 2300 V AC, 1 min.● Material of case:Resin mold (UL94V-1 equivalent)● External dimensions/External dimensions, panel depth Panel cutoutWeight Applicable panel thicknessSRS1H48 × W48 × D66 mm, 62 mm H45×W45 mm Approx. 100 g 1.0–3.5 mmSRS3H96 × W96 × D69 mm, 65 mm H92×W92 mm Approx. 190 g SRS4H96 × W96 × D69 mm, 62 mm H92×W45 mm Approx. 120 g SRS5H48 × W96 × D66 mm, 62 mmH45×W92 mmApprox. 120 gPanel cutout/Weight/Applicable panel thickness:● Mounting:Panel flush mountingTERMINAL COVERMEASURING RANGE CODESInput Type Measuring range (°C)Measuring range (°F)Multi input ThermocoupleB*601*10–1800°C0–3300°FR02-50–1700°C0–3100°FS030–1700°C0–3100°FK04*2-199.9–800.0°C-300–1500°F050–1370°C0–2500°F E060–700°C0–1300°FJ07*2-200–600°C-320–1100°FT*608*2-270–400°C-450–750°FN090–1300°C0–2300°FPLII*3100–1300°C0–2300°FC (WRe 5-26)110–2300°C0–4200°FU*312*2-199.9–400.0°C-300–750°FL130–600°C0–1100°FKelvin K14*410.0–350.0 KAuFe-Cr15*50.0–350.0 KR.T.D.Pt10033-200–600°C-300–1100°F34-199.9–300.0°C-300–600°F mV-10–50 mV72Scaling range: -1999–9999Span: 10–9999 digitVoltage V0–10 V86*1 Thermocouple B: Accuracy guarantee is not applicable to 400 °C and 750 °F or below.*2 Thermocouple K (Celsius, Fahrenheit), E, J, T, U: Accuracy of indicated values below -100 °C and -148 °F is ± (1.5%FS + 1 digit).*3 Thermocouple PL ll, U: Accuracy of indicated values is ±(1.5%FS + 1 digit + 1 °C).*4 Thermocouple K (Kelvin) accuracy temperature range:10.0–30.0K: ±(2.0%FS + 1 digit ) Provided the wire resistance is 10Ω or below31.0–70.0K: ±(1.5%FS + 1 digit ) Provided the wire resistance is 10Ω or below71.0–350.0K: ±(1.0%FS + 1 digit )*5 Thermocouple AuFe, Cr: Accuracy of indicated values is ±(1.0%FS + 1 digit).*6 Thermocouple B, T: Accuracy of indicated values below these temperatures is subject to wire resistance below 50Ω: B: 500 °C and 930 °FT: -240 °C and -400 °F*7 Temperatures below -273 °C and -459 °F are subject to scaleover display.*8 With or without a decimal point is selectable for TC and Pt.NOTE: Unless otherwise specified, the measuring range will be set as follows when shipped from the factory:Input range Code Measuring rangeMulti-input 05K 0–1370 °CVoltage input860–10 VNOTE: For current input install input terminals of the specified receiving impedance (250Ω) and use code 86 (0–10 V).Unit: mmCrimp-type terminals fit M3 screws. Use crimp-type terminals that are no wider than 6.0 mm.■ SRS3/4Crimp-type terminals fit M3 screws. Use crimp-type terminals that are no wider than 6.0 mm.Crimp-type terminals fit M3 screws. Use crimp-type terminals that are no wider than 6.0 mm.en_SRS0_C_201224。
TD-001622-01-A*TD-001622-01*Axon DTH1620 Themed Attraction AmplifierUser ManualModel: DTH1620®EXPLANATION OF SYMBOLSThe term “WARNING!” indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily injury or death.The term “CAUTION!” indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, it may result in damage to the equipment that may not be covered under the warranty.The term “IMPORTANT!” indicates instructions or information that are vital to the successful completion of the procedure.The term “NOTE” is used to indicate additional useful information.The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-insulated«dangerous» voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans.The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important safety, and operating and maintenance instructions in this manual.IMPORTANT SAFETY INSTRUCTIONSTO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN ORWARNING!MOISTURE.Elevated Operating Ambient Temperature – If installed in a closed or multi-unit rack assembly, the ambient operatingtemperature of the rack environment may be greater than room ambient. Consideration should be given to ensure that the maximum operating temperature range -10°C to 50°C (14°F to 122°F ) is not exceeded. Reduced Air Flow – Installationof the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.1. Read these instructions.2. Keep these instructions.3. Heed all warnings.4. Follow all instructions.5. Do not use this apparatus near water.6. Clean only with a dry cloth.7. Do not block any ventilation opening. Install in accordance with the manufacturer’s instructions.8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.9. To reduce the risk of electrical shock, the power cord shall be connected to a mains socket outlet with a protective earthingconnection.10. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than theother. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.11. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where theyexit from the apparatus.12. Only use attachments/accessories specified by the manufacturer.13. Unplug this apparatus during lightning storms or when unused for long periods of time.14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such aspower-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.15. The appliance coupler, or the AC Mains plug, is the AC mains disconnect device and shall remain readily operable after installation.16. Adhere to all applicable, local codes.17. Consult a licensed, professional engineer when any doubt or questions arise regarding a physical equipment installation.18. Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. Clean only with a dry cloth.19. Do not unplug the unit by pulling on the cord, use the plug.20. Do not submerge the apparatus in water or liquids.21. Keep ventilation opening free of dust or other matter.iiTD-001622-01-AiiiTD-001622-01-AMaintenance and RepairWARNING! Advanced technology, e.g., the use of modern materials and powerful electronics, requires specially adapted maintenance and repair methods. To avoid a danger of subsequent damage to the apparatus, injuries to persons and/or the creation of additional safety hazards, all maintenance or repair work on the apparatus should be performed only by a QSC authorized service station or an authorized QSC International Distributor. QSC is not responsible for any injury, harm or related damages arising from any failure of the customer, owner or user of the apparatus to facilitate those repairs. In the event of malfunction, contact QSC Customer Support for assistance.FCC StatementNOTE: NOTE: This equipment has been tested and found to comply with the limits for a Class A or Class B digital device when ferrite clamps are installed on the output cables, pursuant to Part 15 of the FCC Rules. To meet Class A or Class B emission requirements two Ferrite 0431176451 clamps are required to be on the customer-supplied output cables connected to J1 and J5. Place the ferrite clamps as close to connectors J1 and J5 as possible.These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•Consult the dealer or an experienced radio/TV technician for help.EnvironmentalLife cycle 10 years / Storage temperature -20 ° C to + 70 ° C / Relative humidity 5 - 85% RH Service life - 10 years. Storage conditions: temperature from -20 ° C to + 70 ° C, humidity 5% - 85%.If you wish to discard electronic equipment, please contact your dealer or supplier for further information.RoHS StatementThe QSC DTH1620 Series Amplifier is in compliance with “China RoHS” directives. The following chart is provided for product use in China and its territories:QSC DTH1620 and DTH1620 Series Amplifiers有毒有害物质或元素(Toxic or hazardous Substances and Elements)部件名称(Part Name)铅(Pb)汞(Hg)镉(Cd)六价铬(Cr(vi))多溴联苯(PBB)多溴二苯醚(PBDE)电路板组件(PCB Assemblies)XOOOOO 机壳装配件(Chassis Assemblies)X O O O OOO: 表明这些有毒或有害物质在部件使用的同类材料中的含量是在 SJ/T11363_2006 极限的要求之下。
srs安全仪表规格书摘要:1.引言:了解SRS安全仪表规格书的重要性2.SRS安全仪表规格书的主要内容概述3.SRS安全仪表规格书的编写步骤与技巧4.SRS安全仪表规格书在项目中的应用实例5.总结:SRS安全仪表规格书在项目中的重要作用正文:**引言**在现代工业领域,安全仪表系统越来越复杂,为确保项目的安全性和稳定性,SRS(System Requirements Specification,系统需求规格书)安全仪表规格书成为了不可或缺的重要文档。
本文将简要介绍SRS安全仪表规格书的概念、内容、编写方法以及在项目中的应用实例,帮助大家更好地理解和应用这一重要文档。
**SRS安全仪表规格书的主要内容概述**SRS安全仪表规格书是对项目需求的一种详细描述,涵盖了项目目标、功能需求、性能需求、接口需求、安全性需求等方面。
在安全仪表项目中,SRS 文档主要包含以下几个部分:1.项目背景和目标:阐述项目背景、项目目标以及项目预期成果。
2.功能需求:详细描述各个功能模块的作用和功能实现。
3.性能需求:列举项目的性能指标,如响应时间、精度、可靠性等。
4.接口需求:说明各个模块之间的接口关系和数据传输方式。
5.安全性需求:阐述项目的安全目标、安全等级和安全措施等。
6.环境需求:描述项目在各种环境条件下的适应性。
7.法规和标准:列举项目需要遵循的国内外法规、标准和规范。
**SRS安全仪表规格书的编写步骤与技巧**1.明确项目目标:在编写SRS文档前,首先要明确项目目标和预期成果。
2.细化功能需求:针对项目目标,详细描述各个功能模块的作用和实现方式。
3.确定性能指标:结合项目特点,设定合理的性能指标。
4.分析接口关系:梳理各个模块之间的接口关系,明确数据传输方式。
5.撰写安全性需求:依据项目风险评估结果,制定相应的安全措施。
6.考虑环境适应性:分析项目在不同环境下的运行情况,提出相应的要求。
7.遵守法规和标准:确保项目符合相关法规、标准和规范。
2C D C 251 055 V 0011Current monitoring relays CM-SRS.1For single-phase AC/DC currentsThe CM-SRS.1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent from 3 mA to 15 A.All devices are available with two different terminal versions. You can choose between the proven screw connection technology (double-chamber cage connecting terminals) and the completely tool-free Easy Connect Technology (push-in terminals).Characteristics–Monitoring of DC and AC currents (3 mA to 15 A) –TRMS measuring principle–One device includes 3 measuring ranges–Over- or undercurrent monitoring configurable –Hysteresis adjustable (3-30 %) – 3 control supply voltage versions–Precise adjustment by front-face operating controls –Screw connection technology orEasy Connect Technology available–Housing material for highest fire protection classificationUL 94 V-0–Tool-free mounting on DIN rail as well as demounting – 1 c/o (SPDT) contact –22.5 mm (0.89 in) width – 3 LEDs for status indicationApprovals / MarksA C R E L /a bClassifcations:EN 50155, IEC 60571, NF F 16-101/102, EN 45545-2EN 50155, IEC 60571Temp. class Voltage supply Vibration and shockacc to IEC/EN 61373Coated pcb.S1S2C1C2T3nnn-Cat 1, Class BnoNF F 16-101/102EN 45545-2Flammability index Opticity and toxicity of smoke index Risk level achieved I2F2HL3Order dataCurrent monitoring relaysType Rated control supply voltage Connection technology Measuring ranges Order code CM-SRS.11P24-240 V AC/DC Push-in terminals3-30 mA, 10-100 mA, 0.1-1 A1SVR740840R0200 110-130 V AC1SVR740841R0200220-240 V AC1SVR740841R1200 CM-SRS.11S24-240 V AC/DC Screw type terminals3-30 mA, 10-100 mA, 0.1-1 A1SVR730840R0200 110-130 V AC1SVR730841R0200220-240 V AC1SVR730841R1200 CM-SRS.12S24-240 V AC/DC Screw type terminals0.3-1.5 A, 1-5 A, 3-15 A1SVR730840R0300 110-130 V AC1SVR730841R0300220-240 V AC1SVR730841R1300AccessoriesType Description Order code ADP.01Adapter for screw mounting1SVR430029R0100 MAR.12Marker label for devices with DIP switches1SVR730006R0000 COV.11Sealable transparent cover1SVR730005R01002 - Current monitoring relays CM-SRS.1 | Data sheetData sheet | Current monitoring relays CM-SRS.1 - 3Connection technologyMaintenance free Easy Connect Technology with push-in terminalsType designation CM-xxS.yyPApproved screw connection technology with double-chamber cage connecting terminals Type designation CM-xxS.yySPush-in terminals–Tool-free connection of rigid and flexible wires withwire end ferrule–Easy connection of flexible wires without wire endferrule by opening the terminals –No retightening necessary–One operation lever for opening both connectingterminals–For triggering the lever and disconnecting of wiresyou can use the same tool (Screwdriver according to DIN ISO 2380-1 Form A 0.8 x 4 mm (0.0315 x 0.157 in), DIN ISO 8764-1 PZ1 ø 4.5 mm (0.177 in))–Constant spring force on terminal point independentof the applied wire type, wire size or ambientconditions (e. g. vibrations or temperature changes) –Opening for testing the electrical contacting –Gas-tightDouble-chamber cage connecting terminals–Terminal spaces for different wire sizes–One screw for opening and closing of both cages –Pozidrive screws for pan- or crosshead screwdriversaccording to DIN ISO 2380-1 Form A 0.8 x 4 mm (0.0315 x 0.157 in), DIN ISO 8764-1 PZ1 ø 4.5 mm (0.177 in)Both the Easy Connect Technology with push-in terminals and screw connection technology with double-chamber cageconnecting terminals have the same connection geometry as well as terminal position.2C D C 253 025 F 00112C D C 253 026 F 00114 - Current monitoring relays CM-SRS.1 | Data sheetFunctions Operating controls2C D C 251 055 V 00111 Adjustment of the hysteresis (MIN = Default)2 Adjustment of the threshold value (MIN = Default)3 Indication of operational states U/T: green LED – control supply voltage R: yellow LED – relay status I: red LED – over- / undercurrent4 DIP switches (see DIP switch functions)ApplicationThe current monitoring relays CM-SRS.1 are designed for use in single-phase AC and/or DC systems for over- orundercurrent monitoring. The devices are available with different supply voltage ranges and work according to the open-circuit principle. Operating modeThe CM-SRS.1 with 1 c/o (SPDT) contact are available in 2 versions with 3 measuring ranges: 3-30 mA, 10-100 mA, 0.1-1 A (CM-SRS.11) and 0.3-1.5 A, 1-5 A, 3-15 A (CM-SRS.12). The measuring range is selected by connecting the monitored wire to the corresponding terminal B1/B2/B3-C.The units are adjusted with front-face operating controls. The selection of over- b or undercurrent monitoring a ismade with a DIP switch. Potentiometers, with direct reading scale, allow the adjustment of the threshold value I and of the hysteresis %. The hysteresis % is adjustable within a range of 3 to 30 % of the threshold value.Function diagramsOvercurrent monitoring bThe current to be monitored (measured value) is applied to terminals B1/B2/B3-C. The control supply voltage applied to terminals A1-A2 is displayed by the glowing green LED.If the measured value exceeds the adjusted threshold value, the output relay energizes and the red LED (overcurrent) andthe yellow LED (relay energized) glow.If the measured value drops below the threshold value minus the adjusted hysteresis, the output relay de-energizes and the red and yellow LEDs turn off.Undercurrent monitoring aThe current to be monitored (measured value) is applied to terminals B1/B2/B3-C. The control supply voltage applied to terminals A1-A2 is displayed by the glowing green LED.If the measured value drops below the adjusted threshold value, the output relay energizes, the red LED flashes W (undercurrent) and the yellow LED (relay energized) glows.If the measured value exceeds the threshold value plus the adjusted hysteresis, the output relay de-energizes and the red and yellow LEDs turn off.Data sheet | Current monitoring relays CM-SRS.1 - 5Electrical connectionDIP switches6 - Current monitoring relays CM-SRS.1 | Data sheetTechnical dataData at T a = 25 °C and rated values, unless otherwise indicatedInput circuitsSupply circuit A1-A2Rated control supply voltage U s110-130 V AC220-240 V AC24-240 V AC/DC Rated control supply voltage U s tolerance-15...+10 %Rated frequency50/60 Hz50/60 Hz or DC Typical current / power consumption24 V DC--30 mA / 0.75 W115 V AC24 mA / 2.6 VA-17 mA / 1.9 VA230 V AC-12 mA / 2.6 VA11 mA / 2.6 VA Power failure buffering time20 msTransient overvoltage protection varistorsMeasuring circuit B1/B2/B3-CMonitoring function over- or undercurrent monitoring configurableMeasuring method TRMS measuring principleMeasuring inputs CM-SRS.11CM-SRS.121)terminal connection B1-C B2-C B3-C B1-C B2-C B3-Cmeasuring range3-30 mA10-100 mA0.1-1 A0.3-1.5 A1-5 A3-15 Ainput resistance 3.3 Ω 1 Ω0.1 Ω0.05 Ω0.01 Ω0.0025 Ωpulse overload capacity t < 1 s500 mA 1 A10 A15 A50 A100 Acontinuous capacity50 mA150 mA 1.5 A 2 A7 A17 A Threshold value adjustable within the indicated measuring range Tolerance of the adjusted threshold value10 % of the range end valueHysteresis related to the threshold value3-30 % adjustableMeasuring signal frequency range DC / 15 Hz - 2 kHzRated measuring signal frequency range DC / 50-60 HzMaximum response time AC80 msDC120 msAccuracy within the rated control supply voltage toleranceΔU ≤ 0.5 %Accuracy within the temperature rangeΔU ≤ 0.06 % / °CTiming circuitTime delay T V noneRepeat accuracy (constant parameters)±0.07 % of full scaleUser interfaceIndication of operational statesControl supply voltage U/T: green LED V: control supply voltage appliedMeasured value I: red LED V: overcurrentW: undercurrentRelay status R: yellow LED V: output relay energized1) For usage of the current monitoring relays according to UL, following limitations for the measuring circuits are applicable: The load on any single measuring circuit should not exceed15 A at 51-150 V, 10 A at 151-300 V or 5 A at 301-600 V.This limitation is only valid for application according to UL and not for IEC applications.Data sheet | Current monitoring relays CM-SRS.1 - 7Output circuitsKind of output1115-1216/1418relay, 1 c/o (SPDT) contactOperating principle open-circuit principle (output relay energizes if themeasured value exceeds b / falls below a theadjusted threshold value)Contact material AgNiRated operational voltage U e250 VMinimum switching voltage / Minimum switching current24 V / 10 mAMaximum switching voltage / Maximum switching current250 V AC / 4 A ACRated operational current I e AC-12 (resistive) at 230 V 4 AAC-15 (inductive) at 230 V 3 ADC-12 (resistive) at 24 V 4 ADC-13 (inductive) at 24 V 2 AAC rating (UL 508)utilization category (Control Circuit Rating Code) B 300max. rated operational voltage300 V ACmax. continuous thermal current at B 300 5 Amax. making/breakingapparent power at B 3003600/360 VAMechanical lifetime30 x 106 switching cyclesElectrical lifetime AC-12, 230 V, 4 A0.1 x 106 switching cyclesMaximum fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-actingGeneral dataMTBF on requestDuty time100 %Dimensions (W x H x D)product dimensions22,5 x 85,6 x 103,7 mm (0,89 x 3,37 x 4,08 in)packaging dimensions97 x 109 x 30 mm (3,82 x 4,29 x 1,18 in)Weight Screw connectiontechnology Easy Connect Technology (Push-in)net weight CM-SRS.11Version 24-240 V AC/DC0.145 kg (0.320 lb)0.137 kg (0.302 lb)Version 110-130 V AC 0.161 kg (0.355 lb)0.153 kg (0.337 lb)Version 220-240 V AC0.161 kg (0.355 lb)0.153 kg (0.337 lb)CM-SRS.12Version 24-240 V AC/DC0.137 kg (0.302 lb)-Version 110-130 V AC 0.168 kg (0.370 lb)-Version 220-240 V AC0.168 kg (0.370 lb)-gross weight CM-SRS.11Version 24-240 V AC/DC0.147 kg (0.324 lb)0.159 kg (0.351 lb)Version 110-130 V AC 0.183 kg (0.403 lb)0.175 kg (0.386 lb)Version 220-240 V AC0.183 kg (0.403 lb)0.175 kg (0.386 lb)CM-SRS.12Version 24-240 V AC/DC0.159 kg (0.351 lb)-Version 110-130 V AC 0.200 kg (0.441 lb)-Version 220-240 V AC0.200 kg (0.441 lb)-Mounting DIN rail (IEC/EN 60715),snap-on mounting without any tool Mounting position anyMinimum distance to other units10 mm (0.39 in) at measured current > 10 A Material of housing UL 94 V-0Degree of protection housing IP50terminals IP208 - Current monitoring relays CM-SRS.1 | Data sheetElectrical connectionEnvironmental dataAmbient temperature ranges operation-25...+60 °C (-13...+140 °F)storage-40...+85 °C (-40...+185 °F)Damp heat, cyclic (IEC/EN 60068-2-30)55 °C, 6 cyclesVibration, sinusoidal Class 2Shock Class 2Isolation dataRated insulation voltage U i supply / measuring circuit / output 600 Voutput 1 / output 2250 VRated impulse withstand voltage U imp supply / measuring circuit / output 6 kV 1.2/50 μsoutput 1 / output 2 4 kV 1.2/50 μsPollution degree3Overvoltage category IIIStandards / DirectivesStandards IEC/EN 60947-5-1, IEC/EN 60255-27, EN 50178 Low Voltage Directive2014/35/EUEMC Directive2014/30/EURoHS Directive2011/65/EURailway application standardsEN 50155, IEC 60571“Railway applications – Electronic equipment used on rolling stock”temperature class T3 supply voltage category S1, S2, C1IEC/EN 61373“Railway applications – Rolling stock equipment – Shock and vibration tests”Category 1, Class BEN 45545-2 Railway applications – Fire protection on railway vehicles – part 2:Requirements for fire behavior of materialsHL3and components ISO 4589-2LOI 32.3 %NF X-70-100-1 C.I.T. (T12) 0.45EN ISO 5659-2Ds max (T10.03) 104NF F 16-101: Rolling stock. Fire behaviour. Materials choosingNF F 16-102: Railway rolling stock. Fire behaviour. Materials choosing, application forelectric equipmentI2 / F2DIN 5510-2 Preventive fire protection in railway vehicles. Part 2: Fire behaviour and fireside effects of materials and partsfullfilledData sheet | Current monitoring relays CM-SRS.1 - 9Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2Level 3radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3Level 3electrical fast transient / burst IEC/EN 61000-4-4Level 3surge IEC/EN 61000-4-5Level 3conducted disturbances, induced byIEC/EN 61000-4-6Level 3 radio-frequency fieldsInterference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022Class Bhigh-frequency conducted IEC/CISPR 22, EN 55022Class BTechnical diagramsLoad limit curvesDC load (resistive)AC load (resistive)Derating factor F for inductive AC loadContact lifetime10 - Current monitoring relays CM-SRS.1 | Data sheetDimensionsin mm and inchesAccessoriesin mm and inchesCOV.11 - Sealable transparent coverADP.01 - Adapter for screw mounting MAR.12 - Marker label for deviceswith DIP switchesFurther documentationDocument title Document type Document numberElectronic products and relays Technical catalogue2CDC 110 004 C02xxCM-SRS.1, CM-SRS.2Instruction manual1SVC 730 610 M0000You can find the documentation on the internet at /lowvoltage-> Automation, control and protection -> Electronic relays and controls -> Measuring and monitoring relays.CAD system filesYou can find the CAD files for CAD systems at -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls.Data sheet | Current monitoring relays CM-SRS.1 - 11ABB STOTZ-KONTAKT GmbHP. O. Box 10 16 8069006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0Fax: +49 (0) 6221 7 01-13 25E-mail:*****************.comYou can find the address of your local sales organisation on theABB home page/contacts-> Low Voltage Products and Systems Contact usNote:We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in wholeor in parts – is forbidden without prior written consent of ABB AG.Copyright© 2019 ABBAll rights reserved D o c u m e n t n u m b e r 2 C D C 1 1 2 1 6 7 D 0 2 0 1 R e v D ( 0 3 / 2 0 1 9 )。
收音环绕扩音机AVR-1620操作说明书注意:·不能用报纸、桌布、窗帘等物品覆盖通风口,以免妨碍通风。
·不能在设备上放置明火火源,如点亮的蜡烛等。
·应注意电池处置的环保问题。
·设备不能暴露在滴水或溅水的环境下使用。
·不能在设备上放置注有液体的物品(如花瓶)。
Ⅰ「根据电子信息产品污染控制管理办法的有毒·有害物质或元素的标识表」零部件名称对象零部件有毒有害物质或元素备注铅(Pb)汞(Hg)镉(Cd)六价铬(Cr6+)多溴联苯(PBB)多溴二苯醚(PBDE)电路板印刷配线板组件,安装·插入零部件,印刷配线板(不包括特定电子零部件)×○×○○○筐体顶盖,底盖,底壳,框架,垫片,小螺丝等(金属,塑胶),(包含的接合材料)×○○○○○显示器FL,LCD显示器×○○○○○特定电子零部件变压器,插入物,电源插座,电源用大型电解质电容器等电子零部件,机内电缆×○○○○○附件遥控器/AC适配器、电源线、RCA电缆等附件,封装×○○○○○备注:○:在该零部件的所有均质材料中的有毒有害物质的含量不超过在SJ/T11363-2006标准规定的限量要求×:在该零部件中至少一种均质材料中的有毒有害物质的含量超过在SJ/T11363-2006标准规定的限量要求(×判定:包括EU RoHS的豁免项目)此标志是根据2006/2/28颁布的「电子信息产品污染控制管理办法」,以及「电子信息产品污染控制标识要求」,适用于在中国销售的电子信息产品的环保使用期限。
在此产品相关的安全和使用上遵守注意事项,在从生产日期起计算的此年限内,产品中的有害物质不会往外泄漏,或者引起突然变异而给环境污染,人体或财产带来重大影响。
另外,包装在一起的电池等消耗品的环保期限是技术寿命5年。
适当地使用完后废弃的情况,请协助遵守各自治体的电子信息产品回收·再利用相关的法律·规定。
数字化口腔全景X光机数字口腔全景X光机壹台(1)、主要技术参数:1.1适用患者范围:成人、小儿、老人、残疾人1.2电源电压:230~240V± 10, 50/60HZ;1.3球管:*1.3.1 X 线球管:高频直流电,最高140kHZ1.3.2电压&电流:60~90KV, 2~15mA (1mA步阶可调);1.3.3焦点大小:0.5mm;(国际电工委员会IEC336标准)1.3.4主要部件球管、传感器与整套系统为同一工厂生产。
1.3.5两种X线发射方式:锥形线束和锥体散射束满足全景和头颅成像需要1.3.6独特的散热设计,可以连续拍摄超过100个患者无需特殊散热保护1.3.7球管采用符合国家及国际标准最安全的过滤系统:大于2.5mm AL(2)全景功能的要求:1.程序:标准成人全景、全口三分区成像、儿童全景、上颌窦全景、2-截面双侧颞合关节、4-截面双侧颞开合关节、鼻窦全景等;2.预设的病人拍片数据:从三个人头骨的大小及大小体型配合成最符合病人所需的拍片数据3.曝光时间:10.6-13.9 秒4.自动KV补偿技术:在经过颈部时按骨密度自动调整KV,保证前牙区影像清晰;5.三激光束系统定位;6.图像放大倍数:全景为1.27倍放大7.具有患者面对面定位的结构和功能;8.X线发射方式:锥形线束满足全景成像需要(3)头颅测量功能的要求:1.程序:头影测量正位(后前/前后位)、侧位片、眼眶正位、颅底位、掌骨影像、蝶鞍侧位、柯、瓦氏位、鼻骨侧位、环枢椎开口位2.头颅测量区域:可成像(8x10寸)尺寸的侧位片,减少病人曝光的面绩,3.曝光时间:0.1-3.2 秒3.X光接收装置:内置大光圈定焦镜头,将X光投射到头颅成像使用的CCD 传感器上,传感器不用花时间扫描头颅,*4.曝光时间:1秒曝光完成拍摄,大大缩短拍片时间,避免因病人移动而重拍或图像畸变,减少病人吸收射线的时间,延长球管及传感器的使用寿命5.定位光束:单激光束头颅定位6.图像放大倍数:头颅测量为1.5倍放大、7.X线发射方式:锥体散射束满足头颅成像需要(4) 定位方式:1.具有三光束定位2.两个有弹性头额两侧固定支架3.全开放式病人定位:病人背靠升降柱面向外站立时,医生可与患者面对面定位,(4)数字化系统:1.灰度:4096,12比特高灰度,可看出更多层次2.分辨率:2.1二维全景成像:2500*1244 像素2.2二维头颅成像:840*1360像素5.全景图像区域》15X 30厘米,头颅测量图象区域》8X 10英寸;6.图像显示时间:全景在暴光结束后,小于5秒即显示图像;头颅成像曝光后1秒计算机显示图像;*7.两个全景和头颅成像使用的CCD专感器8.固定安装式:所有传感器不用人手拆装,侧位为内置式,全景为可升高式。
srs安全仪表规格书(原创版)目录1.SRS 安全仪表规格书概述2.SRS 安全仪表规格书的主要内容3.SRS 安全仪表规格书的重要性正文一、SRS 安全仪表规格书概述SRS 安全仪表规格书,全称为 Safety Instrumentation Specification,是指针对工业自动化控制系统中的安全仪表设备,所编写的技术规格说明书。
它是确保工业自动化控制系统安全稳定运行的重要依据,对于保障生产安全、防止事故发生具有重要意义。
二、SRS 安全仪表规格书的主要内容1.设备概述:包括设备名称、型号、功能、主要技术参数等基本信息。
2.系统要求:详细描述安全仪表与其他系统之间的接口要求、通信协议、数据格式等。
3.硬件要求:列出安全仪表所需的硬件配置、性能指标、工作环境等要求。
4.软件要求:包括软件功能、性能、兼容性、运行环境等方面的要求。
5.功能要求:详细说明安全仪表需要实现的功能,如报警、联锁、控制、监视等。
6.性能要求:对安全仪表的响应速度、精度、稳定性、可靠性等性能指标作出具体要求。
7.接口和通信要求:描述安全仪表与其他设备或系统之间的接口和通信方式、协议等。
8.电气要求:包括电源、信号、接地等方面的电气性能要求。
9.机械要求:包括设备尺寸、重量、安装方式、防护等级等要求。
10.环境要求:对安全仪表的工作温度、湿度、振动、电磁干扰等环境条件作出要求。
三、SRS 安全仪表规格书的重要性1.确保设备选型准确:SRS 安全仪表规格书明确了设备的技术要求,有助于采购人员正确选择合适的安全仪表设备。
2.保障系统安全稳定运行:详细的规格书可以确保工程技术人员正确安装、调试和维护安全仪表,从而保障整个自动化控制系统的安全稳定运行。
3.提高设备兼容性:SRS 安全仪表规格书有助于确保设备之间的接口兼容性,避免因设备不兼容导致的系统故障。
4.便于后期维护和管理:规格书提供了设备的详细技术参数,有助于运维人员进行设备维护和管理。
(项目名称)需求规格说明书XXXXXXX公司文档修订记录1Software Requirements SpecificationXerox Singapore Software Centre2目 录1 引言 ...................................................................................................................................... 错误!未定义书签。
1.1 背景 ........................................................................................................................... 错误!未定义书签。
1.2 参考资料 ................................................................................................................... 错误!未定义书签。
1.3术语、缩略语 ........................................................................................................... 错误!未定义书签。
2 项目总体概述 ...................................................................................................................... 错误!未定义书签。
2.1 项目描述 ................................................................................................................... 错误!未定义书签。
SRS WOWSRS WOW能显著提升压缩音频的动感音质表现力、扩展音域并强化重低音震撼力。
这些改善让听众获得了无与伦比的高质量优美音色享受。
SRS WOW使用一种全景三维音象,从水平和垂直方向扩展了音场,同时使听众能感受到的低音频率远远低于驱动系统所能支持的低频段。
WOW是SRS实验室原先的四种处理技术完美的集合体。
首先,由一组人头传递函数将立体声场进行扩展与提升,从而使得它与实际扬声器位置相比远远得宽广和生动得多。
然后,通过一种专利心理声学技术,有选择性地将一些在所用扬声器实际承受范围能力之内的低频成分谐波进行增益提升,强化低音表现力。
对于单声道音源,有一种专利技术能合成一个非常自然的立体声场,并没有传统的立体声合成技术不自然的缺陷。
最后,由第二组人头传递函数对声音中的空间信息进行均衡,把声场从扬声器或耳机的水平边界外进一步扩展。
这些人头传递函数的校正曲线能使人脑将音源的位置分析成在其他的特定位置,即便实际扬声器放置在人的前方。
这样一来,整个房间内对音源中各种乐器、歌手的空间定位性都非常好,并且有明显的环绕立体声感受。
对于耳机系统,所使用的人头传递函数将音场从耳机内部扩展到了整个头部的外围。
这一强大的音频处理技术包括了大量的控制与设置,可以使其适用于各种具体产品及回放环境。
不仅如此,WOW中的各个组成部分可随意组合,以适应不同场合的特殊需要。
SRS 3D能恢复声音中的空间信息、导向信息以及其他的细微差别。
这些差别极可能在播放或录制的过程中被错位或丢失。
SRS Focus能纵向提升立体声场并改善语音清晰度。
它可以在很多扬声器位置较低的不理想场合(如汽车或背投电视)中将整个声场提升到一个合适的听觉高度。
而TruBass的心理声学提升技术营造了比扬声器最低截止频率还要低频的深沉、润泽的低音感受。
它能应用于任何扬声器或耳机上,而对于非常小型的扬声器系统特别有效,因为它使得无需再要额外的低音扬声器或附件了。
srs安全规格说明书SRS安全规格说明书1. 简介SRS(Software Requirements Specification)安全规格说明书是为了确保软件系统在安全方面能够满足所有要求而制定的。
它描述了软件系统的安全需求和安全方面的指导方针,确保软件系统的安全性能和可靠性。
2. 安全目标SRS安全规格说明书的安全目标是确保软件系统的机密性、完整性、可用性和可控性。
具体而言,必须满足以下安全要求:2.1 机密性:对软件系统的任何机密信息实行保密管理,防止机密信息被泄露给未经授权的第三方。
2.2 完整性:对软件系统的所有数据、程序和文档实行完整性控制,确保不会被恶意篡改、破坏或损害。
2.3 可用性:确保软件系统始终处于可用状态,在任何情况下都能够正常工作。
2.4 可控性:确保软件系统能够被严格控制和管理,确保仅被授权的人员能够访问和操作系统。
3. 安全措施为了确保软件系统的安全性,必须采取以下安全措施:3.1 访问控制针对软件系统的权限和角色进行访问控制,确保仅被授权的人员可以访问和操作系统。
3.2 数据加密对软件系统中所有机密信息进行加密存储和传输,确保在传输过程中不被泄露或篡改。
3.3 安全审计对软件系统的操作记录进行审计,确保可以追溯所有操作记录,防止恶意操作或人为造成的错误。
3.4 安全培训对参与软件系统开发、维护和使用的人员进行安全培训,确保能够正确使用系统和避免安全风险。
4. 安全测试和评估在软件系统开发完成后,必须进行安全测试和评估。
安全测试应检查是否存在安全漏洞和风险,安全评估应评估系统是否符合所有安全要求和规范。
5. 结论本文所述的SRS安全规格说明书是确保软件系统在安全方面能够满足所有要求而制定的。
对于软件系统的开发、维护和使用,必须严格遵守该规格说明书中所列出的安全要求和指导方针,确保系统安全性能和可靠性。
Dimensions in inches and (millimeters)
Version: C07
SRS1620 - SRS16150
16.0 AMPS. Surface Mount Schottky Barrier Rectifiers
D 2
PAK
Features
For surface mounted application Low forward voltage drop High current capability High reliability
High surge current capability
Mechanical Data
Cases: D 2
PAK molded plastic
Epoxy: UL 94V-0 rate flame retardant Terminals: Pure tin plated, lead free.
solderable per MIL-STD-202, Method 208 guaranteed
Polarity: As marked
High temperature soldering guaranteed:
260o
C/10 seconds at terminals Weight: 1.70 grams
Maximum Ratings and Electrical Characteristics
Rating at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%
Type Number
Symbol SRS 1620 SRS 1630
SRS 1640 SRS 1650 SRS
1660 SRS 1690 SRS 16100 SRS 16150
Units Maximum Recurrent Peak Reverse Voltage V RRM
20 304050 60 90 100150V Maximum RMS Voltage V RMS 14 212835 42 63 70 105V Maximum DC Blocking Voltage V DC 20 304050 60 90 10 150
V Maximum Average Forward Rectified
Current See Fig. 1
I (AV) 16 A Peak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC method )
I FSM 150
A
Maximum Instantaneous Forward Voltage
@8.0A
V F 0.55 0.70 0.90 1.00 V 0.5 0.1 Maximum D.C. Reverse Current @ Tc=25 o
C at Rated DC Blocking Voltage @ Tc=100 o
C
I R 15 10 5.0
mA
mA Typical Junction Capacitance (Note 2) Cj
700 460 320 pF
Typical Thermal Resistance (Note 1) R θJC 2.0
o
C/W Operating Junction Temperature Range
T J -65 to +125
-65 to +150
o C Storage Temperature Range T STG
-65 to +150 o C
Notes: 1. Thermal Resistance from Junction to Case Per Leg
2. Measured at 1MHz and Applied Reverse Voltage of 4.0V D.C.
RATINGS AND CHARACTERISTIC CURVES (SRS1620 THRU SRS16150)
FIG.2- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER LEG
P E A K F O R W A R D S U R G E C U R R E N T . (A )
12
51020100
50 0
50200
150
100
250
300
NUMBER OF CYCLES AT 60Hz
FIG.1- MAXIMUM FORWARD CURRENT DERATI NG CURVE
A V E R A G E F O R W A R D C U R R E N T . (A )
o
CASE TEMPERATURE. (C)
Version: C07
FIG.4- TYPICAL REVERSE CHARACTERISTICS
I N S T A N T A N E O U S R E V E R S E C U R R E N T . (m A )
204060801001201401.0
10
PERCENT OF RATED PEAK REVERSE VOLT AGE. (%)
FIG.6- TYPICAL TRANSIENT THERMAL CHARACTERISTICS
O T R A N S I E N T T H E R M A L I M P E D A N C E . (C /W )
1
0.010.1
10100
0.1
10
1
100
PULSE DURATION. (sec)
FIG.5- TYPICAL JUNCTION CAPACIT ANCE PER LEG
C A P A C I T A N C E .(p F )
200
400
800REVERSE VOLTAGE. (V)
FIG.3- TYPICAL FORWARD CHARACTERISTICS I N S T A N T A N E O U S F O R W A R D C U R R E N T . (A )
INSTANTANEOUS FORW ARD VOLTAGE. (V)。