GENSWITCH 30-1000 AMPERES
Cutler-HammerPRODUCT DESCRIPTIONAn economical line of transfer switches with micro-processor based logic, offering astandard feature package, for basic standbypower applications on 30-1000 ampere systemsup to 600 volts, 2, 3 or 4 pole.STANDARD FEATURES• UL 1008 Listed• Microprocessor Based Logic• Vertical In-Line Mechanism• Multi-Tap Voltage Selector• Normal/Standby Source Monitoring• Group 9 (see below for description)• Plant Exerciser with Fail Safe(Programmable)• High Withstand, Closing, andInterrupting Ratings• Manual Transfer Under Load• Engine Start ContactsFEATURE GROUP 9• Time Delay Normal to Emergency• Time Delay Engine Start• Time Delay Emergency to Normal• Time Delay Engine Cooldown• Emergency Source Sensing• Pilot Light – Normal• Pilot Light – Emergency• Auxiliary Contacts (4NO/4NC) – Normal• Auxiliary Contacts (4NO/4NC) – EmergencyOPTIONAL FEATURES• Time Delay Neutral• NEMA 3R Enclosure• NEMA 12 Enclosure • Pretransfer Signal Contacts (2NO/2NC) • Go To Emergency Contact(Area Protection)
For example, to order the following:Genswitch Automatic Transfer Switch, 480Volts, 60 Hz, 3 phase, 4 wire, 3 pole, 600amperes, NEMA 1 Enclosure, UL ListedThe ordering catalog sequence would be:ATVMMDA30600XSUCutler-HammerPittsburgh, Pennsylvania U.S.A.Publication No. PA.15A.02A.S.EJuly 1999Printed in U.S.A. / DLD2700Copyright Cutler-Hammer Inc., 1999All Rights Reserved.For more information on Cutler-Hammer products and services, call 1-800-525-2000 or 1-616-982-1059,For engineering services call 1-800-498-2678, or visit our web site at www.cutlerhammer.comGENSWITCH 30-1000 AMPERESCBG
ATop of Lugson Power PanelHF
Front View
Plan ViewSide ViewInterior of ATVMKDA20150WSU(deadfront removed)Switch TypePower PanelEnclosureGutter SpaceBolt PatternHWD1HWD2WDBend.Horiz.Vert.(In.)(In.)(In.)(In.)(In.)(In.)(In.)(In.)(In.)(In.)(In.)ABCDEFGHFD (30-150A)11.0017.006.81442118.132114.5411.0042.86KD (150-225A)24.5011.8817.5442119.6384.00611.0042.86KD (300A)24.5011.8817.5522119.6384.00911.0050.86LD (400A)26.0016.8817.5612619.6384.001116.0059.86MDL (600A)36.2516.8817.5732620.6384.751216.0071.86NB (800A)36.2516.8819.0792620.6384.751516.0077.86NB (1000A)36.2516.8819.0792620.6384.751516.0077.86Logic Panel38 in. H x 11 in. W x 6.5 in. DTransformer Panel22 in. H x 16.5 in. W x 6.5 in. D (30-150A)28.63 in. H x 8.25 in. W x 5.5 in. D (150-1000A)1Depth includes the interior handle extended.2Enclosure depth includes the exterior (or door) handle.330-150 Amperes Only.
* Use NB for 4-Pole 600A.AmperesApprox. ShippingWeight (lbs.)30-100210150-300380400430600525800-1000610PA15A02ASEPowerPanelTransformerPanelLogicPanelDEGutterSpace
TYPEPosition 1-2AT = Automatic ORIENTATIONPosition 3V= VerticalH = Horizontal 3LOGICPosition 4M = MicroprocessorFRAMEPosition 5-6Molded caseFD=30-150AKD=150-300ALD=400AMD=600A*NB=800-1000A
SWITCHPosition 7A = Fixed Mount,Molded Case Switch (MCS) BothPOLESPosition 82=2Poles3=3Poles4 = 4PolesAMPERESPosition 9-120030=30A0300=300A0070=70A0400=400A0100=100A0600=600A0150=150A0800=800A0225=225A1000 = 1000AVOLTAGEPosition 13A = 120V 60HzB =208V 60HzE = 600V 60HzG = 220V 50/60HzH = 380V 50HzK = 600V 50HzM = 230V 50HzN = 401V 50HzO = 415V 50HzW=240V 60Hzx = 480V 60HzZ = 365V 50HzENCLOSUREPosition 14R = NEMA 3RS = NEMA1J = NEMA 12LISTINGPosition 15U = ULListedVA TK D0225MA3BRUCATALOG NUMBERS