7”7”40.5” Fixed Position90°Securely mount a control box near the actuator armwith appropriate hardware (notsupplied).Gate Hinge Pivot Point Coaxial CableAntenna Actuator CableP o w e r C o n d u i tL o o p s C o n d u i tFront Bracket Pivot PointFront BracketRear Bracket(Adjustable, See Manual)Rear Bracket Pivot PointClosed PositionOpen to the Inside PositionControl BoxActuator arm and brackets MUST be level !6003-066-P-6-17LimitSlow DownU ns c re w 4 s cr e ws t or em o v ec o ve r .L o os e n nu tt o ad j u s t l i mi t se n s o r .Note: This illustration shows NO gate hinge inset. If gate hinge is inset on wall, see “Rear Bracket Configurations for Different Gate Hinge Insets” in the 6003 Actuator Arm and Control Box Mounting manual.Circuit board power must be ON to adjust limit sensors, LEDs will light.Cut Off Excess BracketCut Off Excess BracketBottomMiddle TopThe 6003 is intended for installation only on swing gates used for vehicles.Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to 6003 Actuator Arm and Control Box Mounting manual, 115 VAC or Solar Control Box Wiring/Owner’s manuals .3 Li m i t5 L i m it 4 Sl oD w n 6 Sl o D wn 120 S. Glasgow Avenue Inglewood, California 90301U.S.A.THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY . Visit to find a professional installing and servicing dealer in your area.M anually release the arm and fully extend the powered shaft. Rotate it back two full turns before installing the arm.Unlock operator to manually move gate.Prevent Powered Shaft from Bottoming OutRotate back 2 turns before installing.Manual ReleaseFully Extended (Bottomed Out)Powered ShaftBrown wire Blue wire Orange wire Red wire Yellow wire Green wire Green/Yellow wireNOT USED7-Wire Operator Actuator CableA support bar must be installed the entire length of the gate to support the pickets.Coaxial Cable Antenna Kit P/N 1514-073 (Sold separately)G a t e C l o s e d21”Typical27.5”Max Photo Sensors HeightClose BeamOpen BeamOpen BeamClose BeamReversing EdgePhoto SensorPhoto SensorSensor mounted just below actuator arm cable.G a t e O p e n e dCopyright 2017 DoorKing, Inc. All rights reserved.External Entrapment Protection DevicesOutside PropertyInside PropertyDO NOT cycle operator before limit sensors andDIP-switches have been adjusted, damage could occur to gate and operator.Single operator connects to PRIMARY connection ONLY on the 115 VAC OR Solar control box circuit board.17865432PRIMARY4302430243025” or lessOpening Direction DIP-Switch 1 (SW 1)Refer to YOUR chosen 115 VAC OR Solar powered control box manuals for complete DIP-switch settings.Manually move the gate to the desired open or closed position. Loosen the limit nuts and slowly slide the limit assemblies until the LIMIT LEDs on the circuit board light up.Rear Bracket ConfigurationsWall2”21/2”3”Straight51/2”Reversing Edge is mounted along ENTIRE end of gate.Potential Entrapment AreaFactory wired jumpers MUST be removed.Operator Opens to the InsideOperator Opens to the InsideNote: Only 1 monitored Device can be connected for each cycling direction. An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices.Refer to YOUR chosen 115 VAC OR Solar powered control box manuals to wire entrapment protection devices.Open to the InsideOpen to the Outside - Refer to 6003 manualNote: Refer to 6003 manual for “Open to the Outside” installation.The operator MUST OPEN GATE upon initial power up and OPEN command.If the operator closes gate after giving open command, shut off power and reverse this switch setting otherwise operator will NOT function correctly.。
QS8005型流程式尿沉渣分析仪管理使用经验苏冰;郭瑞林;杨红霞【期刊名称】《实验与检验医学》【年(卷),期】2009(027)004【摘要】QS8005型流式尿沉渣分析仪是南京千盛医疗设备制造有限公司生产的仿手工法尿沉渣自动分析仪器.符合2002年中华医学会检验分会“血液和体液学专家委员会”通过的《尿沉渣检查标准化建议》的相关规定,采用自动控制尿液浓缩、智能扫描识别尿沉渣形态、计算机图像识别软件等一系列新技术,能快速准确地给出分析结果.提供定量分析结果,使医院检验人员从传统繁重手工尿常规检查的劳动中彻底解放出来,实现了检验部门在尿液分析的全自动化.产品由程控组合式离心系统、抽吸尿上清、沉渣机械手、显微镜检盘、尿沉渣图像自动摄像及识别处理系统组成.各系统装置由可编程控制器(PLC)为主的电气系统控制,【总页数】2页(P414,422)【作者】苏冰;郭瑞林;杨红霞【作者单位】陕西中医学院第二附属医院检验科,陕西,咸阳,712000;陕西中医学院第二附属医院检验科,陕西,咸阳,712000;陕西中医学院第二附属医院检验科,陕西,咸阳,712000【正文语种】中文【中图分类】R446.12+1;R169.39【相关文献】1.“森创”步进及交流伺服系统在流程式尿沉渣分析仪上的应用 [J], ;2.尿沉渣分析仪、尿液干化学分析仪测定及尿沉渣镜检红细胞对比分析 [J], 白士丽;刘长青;王晓丽;郎国华3.QS8005流程式尿沉渣分析仪与尿镜检尿RBC、WBC结果分析 [J], 毛鸿华4.尿干化学分析仪、尿沉渣分析仪及尿沉渣镜检结果对比观察 [J], 张慧丽5.尿干化学分析仪、尿沉渣分析仪和尿沉渣镜检联合应用在尿液红细胞检测中的意义 [J], 康星星;刘娟因版权原因,仅展示原文概要,查看原文内容请购买。
Eaton 198557Eaton Moeller® series Rapid Link - Speed controller, 4.3 A, 1.5 kW, Sensor input 4, AS-Interface®, S-7.4 for 31 modules, HAN Q5, with braking resistanceGeneral specificationsEaton Moeller® series Rapid Link Speed controller1985574015081964321157 mm 270 mm 220 mm 3.42 kg RoHS UL approval IEC/EN 61800-5-1 CE UL 61800-5-1Product NameCatalog NumberEANProduct Length/Depth Product Height Product Width Product Weight Certifications Catalog Notes can be switched over from U/f to (vector) speed control Connection of supply voltage via adapter cable on round or flexible busbar junction Diagnostics and reset on device and via AS-Interface Four fixed speeds integrated PTC thermistorParameterization: drivesConnect mobile (App) Parameterization: drivesConnectDiagnostics and reset on device and via AS-Interface Parameterization: FieldbusParameterization: KeypadSelector switch (Positions: REV - OFF - FWD)Key switch position HANDPC connectionPTC thermistor monitoringInternal DC linkIGBT inverterFour fixed speedsControl unitBreaking resistanceKey switch position AUTOTwo sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operationThermo-click with safe isolationKey switch position OFF/RESETBraking resistance4-quadrant operation possibleBrake chopper with braking resistance for dynamic braking IP65NEMA 121st and 2nd environments (according to EN 61800-3)IIISpeed controllerASIAS-Interface profile cable: S-7.4 for 31 modulesC1: for conducted emissions onlyC2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.2000 VCenter-point earthed star network (TN-S network)AC voltagePhase-earthed AC supply systems are not permitted.Vertical15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaftResistance: 57 Hz, Amplitude transition frequency on accelerationResistance: 6 Hz, Amplitude 0.15 mmResistance: 10 - 150 Hz, Oscillation frequencyResistance: According to IEC/EN 60068-2-6Above 1000 m with 1 % performance reduction per 100 m Max. 2000 m-10 °C40 °C-40 °C70 °CFeatures Fitted with:Functions Degree of protectionElectromagnetic compatibility Overvoltage categoryProduct categoryProtocolRadio interference classRated impulse withstand voltage (Uimp) System configuration typeMounting position Shock resistance Vibration AltitudeAmbient operating temperature - min Ambient operating temperature - max Ambient storage temperature - min Ambient storage temperature - maxIn accordance with IEC/EN 50178 < 95 %, no condensation0.4 - 4.3 A, motor, main circuit Adjustable, motor, main circuit < 10 ms, Off-delay < 10 ms, On-delay 98 % (η)4.1 A3.5 mA120 %Maximum of one time every 60 seconds 380 V480 V380 - 480 V (-10 %/+10 %, at 50/60 Hz)Sensorless vector control (SLV) U/f control BLDC motorsSynchronous reluctance motors PM and LSPM motors 0 Hz500 HzFor 60 s every 600 s At 40 °C6.5 AClimatic proofingCurrent limitationDelay timeEfficiency Input current ILN at 150% overload Leakage current at ground IPE - max Mains current distortion Mains switch-on frequencyMains voltage - min Mains voltage - max Mains voltage toleranceOperating modeOutput frequency - min Output frequency - max Overload current Overload current IL at 150% overload45 Hz66 Hz1.5 kW400 V AC, 3-phase480 V AC, 3-phase0.1 Hz (Frequency resolution, setpoint value)200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section50/60 Hz8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuitCenter-point earthed star network (TN-S network)AC voltagePhase-earthed AC supply systems are not permitted.2 HP≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brakeAdjustable to 100 % (I/Ie), DC - Main circuit765 VDC10 kAType 1 coordination via the power bus' feeder unit, Main circuit 24 V DC (-15 %/+20 %, external via AS-Interface® plug)AS-InterfacePlug type: HAN Q5Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mANumber of slave addresses: 31 (AS-Interface®) Specification: S-7.4 (AS-Interface®)C1 ≤ 1 m, maximum motor cable length C2 ≤ 5 m, maximum motor cable length C3 ≤ 25 m, maximum motor cable lengthMeets the product standard's requirements. Meets the product standard's requirements.Rated frequency - minRated frequency - maxRated operational power at 380/400 V, 50 Hz, 3-phase Rated operational voltageResolutionStarting current - maxSupply frequencySwitching frequencySystem configuration type Assigned motor power at 460/480 V, 60 Hz, 3-phase Braking currentBraking torqueSwitch-on threshold for the braking transistorRated conditional short-circuit current (Iq)Short-circuit protection (external output circuits) Rated control voltage (Uc)Communication interfaceConnectionInterfacesCable length10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise Rapid Link 5 - brochureDA-SW-drivesConnect - InstallationshilfeDA-SW-drivesConnect - installation helpDA-SW-USB Driver PC Cable DX-CBL-PC-1M5DA-SW-Driver DX-CBL-PC-3M0DA-SW-USB Driver DX-COM-STICK3-KITDA-SW-drivesConnectMaterial handling applications - airports, warehouses and intra-logisticseaton-bus-adapter-rapidlink-speed-controller-dimensions-003.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-002.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-004.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions.epsETN.RASP5-4400A31-5120100S1.edzIL034085ZUramo5_v19.dwgrasp5_v19.stpConfiguration to Rockwell PLC for Rapid LinkGeneration Change RA-SP to RASP5Generation change from RA-SP to RASP 4.0Generation change RAMO4 to RAMO5Generation change from RA-MO to RAMO 4.0Generation Change RASP4 to RASP5DA-DC-00004184.pdfDA-DC-00004514.pdfDA-DC-00003964.pdfDA-DC-00004508.pdf10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material10.10 Temperature rise BrochureDisegnieCAD modelIstruzioni di installazione mCAD modelNote per l'applicazione Report di certificazioneEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. Tutti i diritti riservati. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediacalculation. Eaton will provide heat dissipation data for the devices.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.11 Short-circuit rating10.12 Electromagnetic compatibility10.13 Mechanical function。
QS8005流程式尿沉渣分析仪与尿镜检尿RBC\WBC结果分析目的探讨尿液常规检测中尿沉渣分析仪和尿镜检法的作用。
方法用QS8005流程式尿沉渣分析仪对500例临床病人的尿液进行RBC、WBC2个指标进行检测,并与人工镜检法进行比较,将测定数据进行统计分析。
结果红细胞检测阳性符合率为66.2%,阴性符合率为65.9%;白细胞检测阳性符合率为47.5%,阴性符合率为82.6%。
结论显微镜检查检测速度缓慢,耗时较长,尿液分析仪扩大了尿液检测范围,提高了尿液检查的临床价值,但是会受到许多因素的影响,因此,必须两者结合检查,以提高尿液分析的检测质量。
标签:尿液检测尿液分析仪显微镜尿液检测是一项快捷、方便的三大常规检验项目之一,可为临床疾病诊断提供依据。
特别是红细胞,白细胞两项指标的检测意义较大。
2009年5月~2010年5月,笔者对我院500份送检尿液采用尿沉渣分析仪检测尿标本中红细胞和白细胞,并与人工镜检结果进行比较,以了解两种方法的符合率和影响因素。
现将研究结果报告如下。
1材料与方法1.1标本收集门诊及住院病人新鲜中段尿液500例(女性特别注意避免阴道分泌物污染),留尿后1h内完成RBC、WBC的检测及尿液沉渣镜检。
1.2仪器与方法:1.2.1QS8005流程式尿沉渣分析仪(南京千盛医疗设备制造有限公司产),试剂组成:QS8005流程式尿沉渣分析仪专用染色液。
取l0mL尿液,倒入刻度离心管,充分混匀,将进样针插入试管,按进样开关,自动吸取尿标本800μ1,定量分析红细胞、白细胞等参数,记录分析数据。
正常值WBC:0~20/1、RBC:0~20/1。
超出此范围视为阳性。
1.2.2人工镜检。
采用日本欧林巴斯CHK型双目显微镜。
严格按全国临床检验操作规程规定方法操作[1],以RBC小于3个/HP、WBC小于5个/HP为参考值。
检测结果大于正常值为阳性,在正常值内为阴性。
1.3统计学分析用SPSS13.0软件进行分析。
声光启停 手动/自动 急启/急停主控室消防联动NT8005控制系统操作指南一、控制器简介:JB-QB-NT8005火灾报警控制器集报警、消防联动于一体的分布式智能型控制器,采用无极性两总线、2片CPU 同步处理、CAN 总线 通讯、智能算法,具有全数字量、单回路容量大、报警点和联动点任意混接等优点,完全满足风电场消防工作的需要。
二、【火警指示】灯亮时表示有火灾发生。
【启动指示】灯常亮表明系统中有模块正处于启动状态,闪亮表明未收到反馈的信号【反馈指示】表明系统中有设备已启动。
【监管指示】表明系统中有监管信号输入。
【自检指示】表明系统正在进行自检操作。
【故障指示】表明系统中有故障发生。
【屏蔽指示】表明系统中有器件或模块被屏蔽。
备注:红色圈内。
【延时指示】表明系统中有模块正处于延时启动状态。
【模块请启】表明系统发出请求启动信号,有模块正处于等待启动状态。
【主电工作】表明主电工作正常,系统目前正由主电供电。
【备电工作】灯亮时表明目前正由备电供电。
【系统故障】表明程序不能正常运行。
【声光故障】表明系统中有火灾声光警报器故障。
【声光屏蔽】表明系统中有火灾声光警报器被屏蔽。
【传输发送】、【传输接收】、【传输故障】无用。
备注:黄色圈内。
按钮 按钮【声光启动】表明系统中有火灾声或光警报器启动。
【手动/自动】这是一个状态转换键,用来设定系统当前的联动状态。
系统启动后默【声光停止】表明系统中有火灾声或光警报器被启动后停止。
认为手动,按下可切换为自动。
按钮【急启键】当模块处在延时启动或请求启动状态下,按下【急启键】立即启动。
【急停键】当火警页面当模块处在延时启动或启动状态时,按下【急停键】将取消此模块的启动命令,模块恢复正常状态。
【消音键】当有警情发生时,控制器上的扬声器会发出相应的声音,可以按下【消音键】取消报警声音;如果有新的警情,扬声器会重新发出报警声音。
另外,消音键只能消除本控制器扬声器的报警声音,显示盘等设备的报警声音,应使用“操作”的“关闭音响”菜单项。
RD5100 SeriesPrecision water industry pipe and cable locator kitsProvided by: (800)404-ATECAdvanced Test Equipment Rentals®RD5100 range overviewThree products specifically addressing the concerns and challenges of users in the Water Industry locating buried pipes and cables.RD5100H2OA precision locator/transmitter pair offering 83kHzGuidance mode and Power mode with depth.83kHz is very well suited to disjointed pipesand cables, and plastic pipes with tracer wire.The signal can be applied either by direct connectionor by induction, which is also an excellent way of lightingup all nearby conductors for blind locates.RD5100SA precision locator of 3 different sonde frequencies for tracingall types of non-metallic pipe. Upgrade with up to 4 active linelocating frequencies later as your needs develop.RD5100H2O+A precision locating kit offering a suite of active, passive andsonde frequencies specifically targeting the needs of Water Industry users. Guidance mode helps you trace your target with user-friendly visual and audio guides, while iLOC™ allows you to control the transmitter remotely using the locator.iLOCSave time on site by controlling your transmitter from distances of up to 1400 feet / 450 meters.Built for on-site use – IP65 Shock resistant, ingress protected casing protects against knocks, drops, water and dust.34iLOC™RD5100H 2O + locatorGuidance mode – TPI turned offLeft/right arrows, plus a Numerical indication from 0 to 999 of the strength of the field from the target, helps you pinpoint its position. Compass, depth and current, when relevant, are also shown in this mode.Locate over longer distances90V signal output and automatic impedance matching 3 YEAR WARRANTYON REGISTRATION AND AGLOBAL SERVICE NETWORK PROVIDE PEACE OF MINDGuidance modeThe length of the arrow tails is proportional to the distance from the target as the RD5100 guides you towards the pipe or cable of interest. The T arget Position Indicator also indicates the direction to the target.CompassSplash-proof keypadLeft / Right arrowsCurrent, in active modeTarget Position IndicatorSignal strength DepthAlkaline battery pack (2 x LR20 D-cells)Headphone connectionBase tray for accessoriesLight weight and ergonomic design for comfortable useRD5100H 2O + T x transmitterHigh contrast screen provides clarity even in bright sunlight5RD5100H 2O locatorRD5100H 2O Tx transm itterRD5100S locator Internal Li-ion batteries and 4 x D-Cell (LR-20) battery compartmentSonde mode:Detects the signal radiated by a compatible sondeHigh visibility reflective design helps protect operators and equipmentInduction mode alignment arrow:Line arrow up with the target pipe or cable to achieve the best couplingMulti use socket:Direct connection outputAccessory outputLi-ion battery charging inputAlkaline battery pack (2 x LR20 D-cells)Li-Ion rechargeable battery pack(standard on RD5100 H 2O)Signal clamping (Optional)Applies a transmitter signal safely to a pipe or live cable up to 125mm /5" diameter without interrupting the supply.InductionA convenient and quick way of applying the transmitter signal to a pipe or cable, where direct connection or signal clamping is not possible.CD (Current Direction) Identify your target amongsta number of parallel utilities.CD arrows confirm you are tracing your target line.7Copyright © 2018 Radiodetection Ltd. All rights reserved. Radiodetection is a subsidiary of SPX Corporation. Radiodetection, RD5100, TruDepth, Strike Alert and iLOC are trademarks of Radiodetection in the United Kingdom and/or other countries. Due to a policy of continued development, we reserve the right to alter or amend any published specification without notice. This document may not be copied, reproduced, transmitted, modified or used, in whole or in part, without the prior written consent of Radiodetection Ltd.90/RD5100/ENG/02Radiodetection is a leading global developer and supplier of test equipment used by utility companies to help install, protect and maintain their infrastructure networks.Visit Global locationsRadiodetection (USA)28 Tower Road, Raymond, Maine 04071, USAToll Free: +1 (877) 247 3797 T el: +1 (207) 655 8525 *******************Pearpoint (USA)39-740 Garand Lane, Unit B, Palm Desert, CA 92211, USAToll Free: +1 800 688 8094 T el: +1 760 343 7350 **************************Radiodetection (Canada)344 Edgeley Boulevard, Unit 34, Concord, Ontario L4K 4B7, CanadaToll Free: +1 (800) 665 7953 T el: +1 (905) 660 9995 *******************Radiodetection Ltd. (UK)Western Drive, Bristol, BS14 0AF, UKTel: +44 (0) 117 976 7776 *******************Radiodetection (France)13 Grande Rue, 76220, Neuf Marché, France Tel: +33 (0) 2 32 89 93 60 *******************Radiodetection (Benelux)Industriestraat 11, 7041 GD ’s-Heerenberg, Netherlands Tel: +31 (0) 314 66 47 00 *******************Radiodetection (Germany)Groendahlscher Weg 118, 46446 Emmerich am Rhein, Germany Tel: +49 (0) 28 51 92 37 20 *******************Radiodetection (Asia-Pacific)Room 708, CC Wu Building, 302-308 Hennessy Road, Wan Chai, Hong Kong SAR, China Tel: +852 2110 8160 ****************************Radiodetection (China)13 Fuqianyi Street, Minghao Building D304, Tianzhu T own, Shunyi District, Beijing 101312, China Tel:+86(0)1081463372 *********************Radiodetection (Australia)Unit H1, 101 Rookwood Road, Yagoona NSW 2199, Australia Tel: +61 (0) 2 9707 3222 *******************。
五合一编码器1.1 概述五合一编码器是符合MPEG-2/DVB 标准的广播级高品质数字压缩编码设备,可同时对模拟/数字视频和音频信号进行数字压缩处理,通过DVB标准的ASI及SPI接口与其它设备互联互通,编码器增加了前卫电路和内置时基校正电路,对信号源的要求大大降低,保证第一流的视音频质量,并提供完美的画质。
五合一编码器支持各种标准的视频和音频信号接口,包括模拟分量S-VIDEO、模拟复合视频以及单声道或模拟立体声等。
压缩数据输出格式为ASI/SPI。
压缩输入采用MPEG-2 MP@ML编码,编码器对音频信号进行MPEG-2实时编码和复用并产生DVB传输流。
完全符合MPEG-2标准,具有极强的兼容性。
1.2 特点✧对4路音视频信号编码并复用产生1路MPTS流✧支持MPEG-2 MP@ML (4:2:0)编码;✧高保真音频处理技术R/L声道,立体声输入;✧输出码率连续可调,使用灵活方便;✧丰富的输出输入接口,实现自由接入;✧可本地和远程控制网管;✧液晶显示,操作方便灵活;✧高可靠性设计,运行稳定。
✧码流复用功能✧PID 显示和设置✧SDT,节目名和提供商设置应用范围有线电视数字前端;卫星数字电视广播;地面数字电视;图像监控;视频点播(VOD);远程教学;会议电视。
1.3 性能指标1.4原理框图1.5外形图与说明前面板示意图:后面板示意图:第2章安装指南2.1 收货检查打开设备包装箱校验物品,务必检查小部件的包装材料,对照产品装箱清单或者下列项目检查包装箱中的物品:五合一编码器1台用户手册1份模拟音、CVBS复合视频输入线3根交流输入电源插线1根如果这些物品与项目或者清单不符合,请立即与公司联系。
2.2 安装准备安装设备时,应按以下步骤。
设备安装时每个细节将在这一章的其余部分描述,具体的位置可参照后面板示意图。
本章主要包括以下内容:∙ 检查运输期间,可能发生的设备的丢失或损坏;∙ 准备装机的合适环境;∙ 安装编码器;∙ 信号线的连接;∙ 通讯端口连接(可选)。
Safe Manifold OperationsThe family of Wide-Pattern Five-Valve Manifolds was developed as an added safety feature, uniquely positioning the valves at an increased distance compared to standard designs. Theadded space between the valves reduces the accidental opening of nearby valves due to close proximity . Not only does the valve positioning improve functionality , but it also helps avoid “finger pinching” for the field technicians.The Wide-Pattern Manifolds also feature our patented Pressure-Core ® Stem Seal technology that requires no bonnet adjustment and eliminates leaks that would result in measurement drift and fugitive emissions. Parker takes great pride in extending a five-year limited warranty on our Pressure-Core Stem Seal, far exceeding the industry standard.Product Features:• Unique configuration for “no finger pinching” operation of all five valves • Easy access to both high and low side test / pressure ports • Down or back oriented vent port for safetyWide-Pattern ™ ManifoldsEliminates Finger PinchingContact Information:Parker Hannifin Corporation PGI Division16101 Vallen DriveHouston, TX 77041 USA phone 713 466 0056fax 800 568 9228********************/pgi2M-575Chart Recorder Manifold1/2" FNPT x 1/2" FNPT x 1/4" NPT• Integrated block valves for fewer leak points than “bar” type construction • Down oriented vent port for safety • Compact one-piece design for fast, easy installation • Easy access to both high and low side test / pressure ports • 1/2" NPT inlet connection with 2-1/8" centersEqualizeIsolateVent(2) 1/4" NPT Test/Pressure Ports (on back)1/2" NPT Inlet 2-1/8" Centers1/4" NPT Vent PortOrdering InformationPatented3M-6755-Valve Manifold1/2" FNPT x Flange x 1/4" FNPTM-7755-Valve ManifoldFlange x Flange x 1/4" NPT• Down oriented vent port for safety • Easy access to both high and low side test / pressure ports • 1/2" NPT inlet connection with 2-1/8" centersOrdering InformationEqualizeIsolate(2) PTFE Face Seals on 2-1/8" Centers1/2" NPT Inlet 2-1/8" Centers1/4" NPT Vent PortVentIsolate(2) 1/4" NPT Test/Pressure Ports(4) Instrument Mounting BoltsAdapted for Bracket MountingPatented4M3-5755-Valve Large Bore Manifold1/2" FNPT x 1/2" FNPT x 1/4" NPTM3-6755-Valve Large Bore Manifold1/2" FNPT x Flange x 1/4" FNPT• .375" diameter through bore to minimize gauge line error • Down oriented vent port for safety • Easy access to both high and low side test / pressure ports • 1/2" NPT inlet connectionOrdering InformationEqualizeIsolate(2) PTFE Face Seals on 2-1/8" Centers1/2" NPT Inlet1/4" NPT Vent PortVentIsolate(2) 1/4" NPT Test/Pressure Ports(4) Instrument Mounting BoltsAdapted for Bracket MountingPatented5M3-775Valve ManifoldFlange x Flange x 1/4" NPT• .375" diameter through bore to minimize gauge line error • Back oriented vent port for safety • Easy access to both high and low side test / pressure ports • Flange inlet on 2-1/8" centersEqualizeIsolate(2) PTFE Face Seals on 2-1/8" CentersFlange Inlet on 2-1/8" Centers1/4" NPT Vent Port on BackVentIsolate(2) 1/4" NPT Test/Pressure Ports(4) InstrumentMounting BoltsOrdering InformationPatentedM-5813-Valve Instrument Mounted Equalizer Manifold1/4" FNPT x Flange x 1/4" NPT• .136" diameter through bore to minimize gauge line error• Angled vent valve for ease of operation • Down oriented vent port for safety • Easy access to both high and low side test / pressure ports• 1/4" NPT inlet connectionOrdering InformationEqualize(2) PTFEFace Seals1/4" NPTVent PortAngled Vent(2) 1/4" NPT Test/Pressure Ports(on back)(4) InstrumentMounting BoltsEqualize.136"ThroughBore67Pressure & Process Temperature RatingsTo determine the pressure and temperature rating of your product, choose your body, seat, and then seal. Then use the lowest maximum pressure and temperature rating of the three selected criteria.To determine the low temperature rating, use the highest minimum rating.Parker Hannifin Corporation PGI Division16101 Vallen Drive Houston, TX 77041USAphone 713 466 0056fax 713 744 9897*************************/pgi Parker Hannifin Corporation PGI Division18 Huashan Road, New District Changzhou, Jiangsu 213022Chinaphone +86 519 8980 7258fax +86 519 8980 7212Parker Hannifin Corporation PGI Division11, Fourth Chin Bee Rd 619702Singaporephone +65 6887 6300fax +65 6265 5125Parker Hannifin Corporation PGI Division2620 21st Street NE Calgary, Alberta T2E 7L3Canadaphone 403 291 3154fax 403 291 3292Sales Offices WorldwideYour Local Authorized Parker DistributorParker Hannifin Corporation PGI Division16101 Vallen Drive Houston, Texas 77041phone 713 466 0056fax 713 744 /pgiPGI-WPM Nov 2014© 2014 Parker Hannifin CorporationSafety Guide – See /safety.。
©W e s t e r m o T e l e i n d u s t r i A BUser Guide6644-2240Legal informationThe contents of this document are provided “as is”. Except as required by applicablelaw, no warranties of any kind, either express or implied, including, but not limited to,the implied warranties of merchantability and fitness for a particular purpose, are madein relation to the accuracy and reliability or contents of this document. Westermoreserves the right to revise this document or withdraw it at any time without priornotice.Under no circumstances shall Westermo be responsible for any loss of data or incomeor any special, incidental, and consequential or indirect damages howsoever caused.More information about Westermo can be found at the following Internet address:26644-224036644-2240SafetyBefore installation:Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.This unit should only be installed by qualified personnel.This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.This unit uses convection cooling.T o avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section).Before mounting, using or removing this unit:Prevent access to hazardous voltage by disconnecting the unit from power supply.Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.Class 1 Laser ProductDo not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations.Care recommendationsFollow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.This unit must not be operating with removed covers or lids.Do not attempt to disassemble the unit. There are no user serviceable parts inside.Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.Do not paint the unit. Paint can clog the unit and prevent proper operation.Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo T ech support.Fibre connectors are supplied with plugs to avoid contamination inside the optical port.As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied.SPECIAL CONDITION FOR SAFE USEAmbient temperature:This unit is designed for use in extreme ambient temperature conditions according to the following: –40 ºC to +74 ºC (–40 ºF to +165 ºF)Note. Fibre Optic HandlingFibre optic equipment needs special treatment. It is very sensitive to dust and dirt. Ifthe fibre will be disconnected from the modem the protective hood on the transmitter/ receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.If this recommendation is not, it jeopardises the warranty.Cleaning of the optical connectorsIn the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick.Recommended cleaning fluids:• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol• Hexane• NaphthaMaintenanceNo maintenance is required, as long as the unit is used as intended within the specified conditions.Agency approvals and standards compliance46644-2240Declaration of ConformityWestermo Teleindustri ABPierre Öberg6644-22405Type tests and environmental conditions66644-2240DescriptionThe SDW-541-F1G-T4G is an unmanaged 5-port switch with one SFP fibre port and four copper ports, all supporting 100 Mbit/s or Gbit Ethernet. The Westermo rangeof 100Mbit or Gbit Small Form-factor Pluggable (SFP) transceivers are available as multimode, singlemode or Bi-Di transceivers with distance up to 120 km.The SDW-550-T5G is an unmanaged 5-port Array switch with five copper ports, all supporting 10Mbit/s, 100 Mbit/s or Gbit Ethernet. Both aredesigned for easy use in heavy duty industrial,maritime and rail trackside applications. Theunits support 802.1Q long packets which allowall standard industrial Ethernet protocols tobe used.The units are designed for use in industrialapplications with dual 10 to 57 VDC powerinput. The unique “tri-galvanic” isolationprovides isolation between all ports, powersupply and between each chassis screenavoiding ground loop currents. The IP21rating ensures that the unit can be installed inlocations where condensed water may occur.Only industrial grade components are usedwhich gives an MTBF of 1.182.000 hours forthe SDW-541-F1T4G and 1.121.000 hours forthe SDW-550-T5G and thus ensures a longservice life. A wide operating temperaturerange of –40 to +74 °C (–50 to +165 °F) canbe achieved with no moving parts.The units have been tested both by Westermo and external test houses to meet EMC, isolation, vibration and shock standards, all to the highest levels suitable for heavy industrial, trackside and maritime environments.Network diagnostics are simplified with the inclusion of port mirroring on one port allowing data flow through the switch to be monitored using a network analyzer. All five ports can have data rate and flow control locked by DIP switch which can eliminateproblems with old legacy Ethernet equipment that is unable to support auto negotiation.6644-22407Interface specifications* Refer to Safety section.** T o minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.86644-224096644-2240ConnectionsPower connectionNetworkfibre connectionLED indicatorsAvailable models:… SDW-541-F1G-T4G 10/100/1000Base-T/TX: 4 ports, 100/1000Base-FX: 1 port … SDW-550-T5G 10/100/1000Base-T/TX: 5 portsSDW-541-F1G-T4G SDW-550-T5G106644-22401234PowerThe SDW-500 series supports redundant power connection. The positive inputs are DC1 and DC2, the negative inputs for both supplies are –COM. The power is drawn from the input with the highest voltage.TXEthernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover.CAT 5 cable is recommended.Unshielded (UTP) or shielded (STP) connector might be used.87654321F1G, 1 SFP slotsThe F1G interface has one SFP slot supporting Ethernet 10/100/1000 BaseFX/X. Each slot can hold one SFP transceiver for copper or fibre cable. For supported transceivers see SFP transceivers user guide (art no. 6100-0000) available at www.westermo. com.DIP switch settings SDW-541-F1G-T4G and SDW 550-T5GDIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit.Warning!discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed.Warning! Do not open connected equipment.Prevent access to hazardous voltages by disconnecting the unit from AC/DC mainssupply and all other electrical connections.NOTEWhen configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).Observe this when the DIP-switches are configured… S peed and duplex setting only valid when auto-negotiation is disabled.… W hen monitoring selected all outgoing packets from the switch is also copied to the port 1.… S peed and duplex switch settings are ignored for FX ports.… I f auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.… I f Hub mode is selected, all incoming and outgoing packets are distributed on all other ports.ONLY VALID FOR SDW-541-F1G-T4G… S peed and duplex switch settings are ignored for FX ports.… I f auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.6644-224011126644-2240Port settings136644-2240G ig ab it T ra n sc00 seLED indicatorsLEDSFP T ransceiversThe unit supports Westermo labelled transceivers only.See Westermo's modular transceivers datasheets 100 Mbit and 1 Gbit for supportedSFP transceivers. See T ransceiver User Guide "6100-0000" for transceiver handlinginstructions.100 M b it TRe dF ox, L ynx se00 s er ie s146644-2240MountingCoolingThis unit uses convection cooling.T o avoid obstructing the airflow around the unit, use the following spacing rules. Minimum spacing 25 mm (1.0 inch) above / below and 10 mm (0.4 inches) left / right the unit. Spacing is recommended for the use of unit in full operating temperature range and service life.* S156644-2240REV . B 6644-2240 2016-02 Westermo T eleindustri AB, SwedenFor complete contact information, please visit our website at /contact or scan the QR codeChina********************* France*****************www.westermo.fr Germany****************www.westermo.deNorth America **************** Singapore******************.sg Sweden************************www.westermo.seUnited Kingdom *****************.uk Other OfficesSales UnitsWestermo Data Communications Westermo • SE-640 40 Stora Sundby, Sweden T el +46 16 42 80 00 Fax +46 16 42 80 01E-mail:*****************。
感谢您购买 产品!请仔细阅读本手册,它将帮助你妥善设置并运行您的系统,使其发挥卓越的性能。
并保留这些说明以供日后参照。
警告:为了降低火灾与电击的风险,请不要将产品暴露在雨中或潮湿环境中。
警告:为了降低电击的风险,非专业人士请勿擅自拆卸该系统。
仅供专业人士操作。
等边三角形中的闪电标记,用以警示用户该部件为非绝缘体,系统内部存在着电压危险,电压。
可能足以引起触电。
可能足以引起触电如系统标有带惊叹号的等边三角形,则是为提示用户严格遵守本用户指南中的操作与维护规定。
注意:请勿对系统或附件作擅自的改装。
未经授权擅自改装将造成安全隐患。
警告:燃不得将明火源(如点的蜡烛)放在器材上面。
1. 请先阅读本说明。
2. 保留这些说明以供日后参照。
3. 注意所有警告信息。
4. 遵守各项操作指示。
5. 不要在雨水中或潮湿环境中使用本产品。
6. 不要将产品靠近热源安装,例如暖气管、加热器、火炉或其它能产生热量的装置(包括功放机 )。
7. 不要破坏极性或接地插头的安全性设置。
如果提供的插头不能插入插座,则应当请专业人员更换插座。
8. 保护好电源线和信号线,不要在上面踩踏或拧在一起(尤其是插头插座及穿出机体以外的部分 )。
9. 使用厂商规定及符合当地安全标准的附件。
10.雷电或长时间不使用时请断电以防止损坏产品。
12. 不要让物体或液体落入产品内——它们可能引起火灾或触电。
13. 请注意产品外罩上的相关安全标志。
. 仅与厂商指定或与电器一同售出的推车、架子、三脚架、支架或桌子一起使用。
推动小车/电器时,应谨防翻倒。
11注意事项产品的安装调试须由专业人士操作。
在使用非本厂规定的吊装件时,要保证结构的强度并符合当地的安全规范。
警告:1扬声器及扬声器系统的产品有限保修期为自正式购买日起的3年。
由于用户不合理的应用而导致音圈烧毁或纸盆损坏等故障,不包含于产品保修项目。
产品吊附件(包括音箱装配五金件和吊挂配件)的有限保修期为自正式购买日起的1年。
探讨尿液有形成分检验如何标准化摘要】随着高科技时代的到来,检验仪器的自动化发展,尿液有形成分的检验方法也随之发生了根本性的变化。
从过去简单的物理目测、显微镜检查已发展到全自动尿液流式细胞分析仪,极大地提高了尿液检验的准确度。
然而我国地域辽阔,医院之间技术水平不均衡,经济水平差距较大,还有在现实中存在着临床科室急于要求检验科迅速发出报告的急诊情况,这种急诊与规范性检验要求相矛盾,使得检验科无法进行尿液有形成分标准化检查。
本文就近年来国内尿液有形成分检验如何标准化作以探讨。
【关键词】尿液有形成分标准化1 尿液有形成分检验的概述在尿液形成过程中,泌尿道常有组织的脱落物和细胞渗出,尿离体离心或自行沉降,其沉降物称为尿沉渣,是尿液中的有形成分,包括细胞、管型、细菌、霉菌、结晶、药物等。
尿沉渣检查是尿液分析的重要组成部分,对肾脏疾病、泌尿道疾病、循环系统疾病以及感染性疾病等有重要的诊断价值和鉴别价值。
以往直接将尿液离心,取沉渣在显微镜下检查,称为“尿沉渣检查”[1],而开展的流式原理自动化检查方法,无需离心即可直接分析尿中有形成分,称为尿有形成分分析[2]。
同样中华检验医学大辞典对尿液分析(Urinalysis)下了明确定义:“用目测、理学、化学(应强调定性、定量)、显微镜及其他仪器(各种尿分析仪、渗透压计等)对尿液标本进行分析,以达到对泌尿、循环、肝、胆、内分泌等疾病进行诊断、疗效观察及预后判断等目的。
[3]”因此,尿液有形成分检验对疾病进行诊断、定位、鉴别和病情预后的判断均有不可替代的作用。
2 尿液有形成分检验的方法及仪器临床应用的差异性2.1传统尿液有形成分的检验尿液有形成分分析尽管有多种方法,但在一些欠发达地区的基层医院目前临床任然常用的包括显微镜检查法、干化学方法。
传统的离心后显微镜检查法,即取混匀的新鲜尿液10ml于一刻度管内,用回转半径15cm的水平离心机以1500r/ min(RCF=378G)沉淀5min,取出离心管倾去上层液体使剩约0.2ml,混匀管底沉淀物,用吸管吸出沉淀物的20μl,滴于载玻片上,用盖玻片覆盖后镜检。
T E C H N O L O G Y G M B Hflowtronic S8005C 油耗仪含传感器, 信号调制单元, 热交换器和附件flowtronic S8005C流量传感器,信号调节单元、热交换器和燃料消耗测量附件。
说明S8005C流量传感器是一种测量内燃机耗油量的传感器,由于它操作简单,持久耐用,品质优良,目前已广泛用于各种燃料如:汽油、柴油、酒精和生物燃料等消耗量的测量。
30年以来,起初作为瑞士级精度标准的Flowtronic油耗测试设备已被世界广泛接受,而德国的GREGORY技术公司拥有着该设备的全部生产线,并一直致力于把它作为一种产品和服务来开发。
新一代的流量传感器S8005引进了最新的传感技术以及热交换单元、信号处理技术,适用于汽油、柴油、现在也可以用于酒精燃料和生物燃料的消耗量测量。
该传感器有三个不同的最大测量范围:100,150,250升/小时,用户可根据自己的实际需要来进行选择。
它的使用范围也覆盖了乘用车,货车,重型车辆,特殊用途车辆,摩托车以及轮船等移动的车辆,而且也可以在静止的台架上试验中使用,这种流量传感器几乎适用于所有的供油系统。
带回油系统的发动机需要对供油系统额外的调制。
为了达到这个目的,我们有可选的热交换器HE8005。
它使得传感器适用于更广泛的先进的燃料供应系统发动机(例如:共轨柴油发动机)。
同时,也能防止高温工况下在发动机供油回路中产生气泡。
Flowtronic流量传感器S8005C需要一个外部信号处理器SE8005D或S8005ADT E C H N O L O G Y G M B H配合使用。
结合信号调制单元,S8005C传感器具有以下特点:●已在全世界广泛使用并被验证的flowtronic 流量传感器,在分辨率和精确度也有改进。
●牢固的模块化结构,尺寸紧凑,需要的维护少●测量范围0.1到240l/h,与最大流量170l/h的热交换器结合使用●内部燃油泵可提供的循环流量170h/h●可对供有系统进行调制●适用于汽油、柴油、酒精燃料和生物燃料发动机●热交换单元和压力调节单元(可选)●带触摸屏显示器的外部信号调制单元,操作简单,带数字和模拟信号输出到RS232/USB接口与外部PC或打印机,带距离传感器或基于GPS的系统的信号输入,已进行距离有关的油耗测量,用于外部PC的数据传输和存储的软件●燃油温度和压力传感器(可选)●通过LCD触摸屏简易操作(只有SE8005D信号调节单元才有)。
声光Q开关电源使用说明书(适用于QSD5027、QSD7527)桂林市飞鹰激光应用技术有限公司欢迎您使用我公司生产的QSD系列Q开关电源。
在使用QSD系列Q开关电源之前,请您务必仔细阅读本使用手册。
本手册适用于QSD系列标准产品。
对于用户有特殊要求的特制产品,请仔细阅读手册中另附的特别说明。
请您打开包装箱,核对随机附件。
电源线一根15芯计算机针式插头一只Q9插头一套目录一、简介 1 1.概述....................... 错误!未定义书签。
2.型号说明................... 错误!未定义书签。
3.主要性能和技术指标......... 错误!未定义书签。
二、工作原理及结构. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 31.Q开关元件结构及工作原理.... 错误!未定义书签。
1.1.结构.................. 错误!未定义书签。
1.2.Q开关关断激光原理 ..... 错误!未定义书签。
1.3. Q开关进行Q调制 ........ 错误!未定义书签。
1.4.Q开关的等效阻抗....... 错误!未定义书签。
2.Q电源结构与原理............ 错误!未定义书签。
2.1.开关电源及射频功率的调节 .. 错误!未定义书签。
2.2.射频单元.............. 错误!未定义书签。
2.3.主控单元 (8)2.3.1.控制电源 (8)2.3.2.控制方式 (8)2.3.3.调制脉冲及出光控制有效电平的设置122. 3. 4. 保护逻辑 (12)2.3.4.1.超温保护 (12)2.3.4.2.外控保护 (12)2.3.4.3.反射保护 (13)2.4.对外接口 (13)2.5.控制面板.............. 错误!未定义书签。
2.5.1.数显表.................................... ..17 2.5.2.RUN/STOP指示灯. (17)2.5.3.ALARM(报警)指示灯 (18)2.5.4.TEST(测试)指示灯 (18)2.5.5.M1、M2、M3 指示灯 (18)2.5.6.按键说明 (18)2.5.7.电源开关 (20)三、电源与Q开关元件的阻抗匹配 20四、安装及操作说明 211.安装条件 (21)2.电气安装连线 (21)3.操作流程说明 (23)五、异常现象释疑…………………………………………. ..23附图 (26)一、简介1.概述QSD系列Q开关电源是针对不同的应用领域精心设计的高品质的声光Q开关(Acousto-Otipc Q-switch)驱动电源。
T E C H N O L O G Y G M B Hflowtronic S8005C 油耗仪含传感器, 信号调制单元, 热交换器和附件flowtronic S8005C流量传感器,信号调节单元、热交换器和燃料消耗测量附件。
说明S8005C流量传感器是一种测量内燃机耗油量的传感器,由于它操作简单,持久耐用,品质优良,目前已广泛用于各种燃料如:汽油、柴油、酒精和生物燃料等消耗量的测量。
30年以来,起初作为瑞士级精度标准的Flowtronic油耗测试设备已被世界广泛接受,而德国的GREGORY技术公司拥有着该设备的全部生产线,并一直致力于把它作为一种产品和服务来开发。
新一代的流量传感器S8005引进了最新的传感技术以及热交换单元、信号处理技术,适用于汽油、柴油、现在也可以用于酒精燃料和生物燃料的消耗量测量。
该传感器有三个不同的最大测量范围:100,150,250升/小时,用户可根据自己的实际需要来进行选择。
它的使用范围也覆盖了乘用车,货车,重型车辆,特殊用途车辆,摩托车以及轮船等移动的车辆,而且也可以在静止的台架上试验中使用,这种流量传感器几乎适用于所有的供油系统。
带回油系统的发动机需要对供油系统额外的调制。
为了达到这个目的,我们有可选的热交换器HE8005。
它使得传感器适用于更广泛的先进的燃料供应系统发动机(例如:共轨柴油发动机)。
同时,也能防止高温工况下在发动机供油回路中产生气泡。
Flowtronic流量传感器S8005C需要一个外部信号处理器SE8005D或S8005ADT E C H N O L O G Y G M B H配合使用。
结合信号调制单元,S8005C传感器具有以下特点:●已在全世界广泛使用并被验证的flowtronic 流量传感器,在分辨率和精确度也有改进。
●牢固的模块化结构,尺寸紧凑,需要的维护少●测量范围0.1到240l/h,与最大流量170l/h的热交换器结合使用●内部燃油泵可提供的循环流量170h/h●可对供有系统进行调制●适用于汽油、柴油、酒精燃料和生物燃料发动机●热交换单元和压力调节单元(可选)●带触摸屏显示器的外部信号调制单元,操作简单,带数字和模拟信号输出到RS232/USB接口与外部PC或打印机,带距离传感器或基于GPS的系统的信号输入,已进行距离有关的油耗测量,用于外部PC的数据传输和存储的软件●燃油温度和压力传感器(可选)●通过LCD触摸屏简易操作(只有SE8005D信号调节单元才有)。
Pool and spa ventilation modelsHeat Recovery VentilatorsfantechSHR 8005R • SHR 14105RYour ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of such requirements, with the current edition of the National Building Code, and / or ASHRAE’s “Good Engineering Practices”.Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position. Please visit our website for more detailed technical information.United States10048 Industrial Blvd., Lenexa, KS, 66215Tel.: 800.747.1762 • Fax: 800.487.9915Canada50 Kanalflakt Way, Bouctouche, NB, E4S 3M5Tel.: 800.565.3548 •Fax: 877.747.81162PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT Before installation, careful consideration must be given to how this system will operate if connected to any other piece of mechanical equipment, i.e. a forced air furnace or air handler, operating at a higher static. After installation, the compatibility of the two pieces of equipment must be confirmed by measuring the airflow’s of the Heat / Energy Recovery Ventilators. It is always important to assess how the operation of any HRV/ERV may interact with vented combustion equipment (i.e. Gas Furnaces, Oil Furnaces, Wood Stoves, etc.).Install a ventilator in a situation where its normal operation, lack of operation or partial failure may result in the backdrafting or improper functioning of vented combustion equipmentProducts are designed and manufactured to provide reliable performance, but they are not guaranteed to be 100% free of defects. Even reliable products will experience occasional failures, and this possibility should be recognized by the user. If these products are used in a life support ventilation system where failure could result in loss or injury, the user should provide adequate back-up ventilation, supplementary natural ventilation or failure alarm system, or acknowledge willingness to accept the risk of such loss or injury.Your ventilation system should be installed in accordance with the local building code that is in effect, in absence of such requirements, it is recommenced to check with local authorities having jurisdiction in your area prior to installing this product.fantech3fantechTABLE OF CONTENTSINSTALLATIONLocation ...........................................................................5 Port Configuration.....................................................................6 Installing Drain Line....................................................................6 Installing Duct Connections (7)AIRFLOW BALANCING.........................................................................8INSTALLING BYPASS MODULE (BPM)..............................................................9INSTALLATION EXAMPLES......................................................................9MODES OF OPERATION.......................................................................10 Speed Setting .......................................................................10LOW VOLTAGE CONTROL SYSTEMS..............................................................11MAINTENANCE.............................................................................12ELECTRICAL CONNECTIONS....................................................................13INSTALLATION VERIFICATION TEST (14)fantech5 Installationfantech6fantechPort configurationThe unit has access doors on the front and back. Also, the main control panel may be moved from front to back allowing for ducting layout.Standard Configuration as shipped from factory.Factory Setting. Unit may be easily reversed in field.7 Installing ducts going to / from outsideINSTALLING THE DUCTING TO THE WEATHERHOODSOUTSIDE WEATHERHOODS – The weatherhoods must have built-in "bird" screens with 6.35 mm (1/4 inch) minimum mesh to prevent birds and rodents from entering into the ductwork. Do not use smaller mesh as it will be very susceptible to plugging up. The preferred location of the weatherhoods is:• N o less than 3 m (10 ft.) apart from each other.• A t least 457.2 mm (18 inches) snow line or ground level.• S upply hood must be kept away from sources of contaminant, such as automobile exhaust fumes, gas meters, garbage cans, containers, cooling towers, tar roofs, etc.• A void prevailing winds, whenever reasonably possible.The outside perimeter of the weatherhood must be sealed to prevent leakage into the building.DUCTING FROM THE WEATHERHOODS –TO AND FROM THE HRV – Galvanized sheet metal ducting with sufficient cross section with an integral single piece of insulated wrap with vapor barrier should be used to connect the HRV to the weatherhoods. The R-value of the insulation should be adequate for condensation control. Insulated flex duct may be used in moderation, if sized and installed properly. (Consult local codes)All ducts should be sealed using a good bead of high quality caulking (preferably acoustical sealant) and a high quality aluminum foil tape, or other approved duct sealant.fantech8fantech A The duct’s airflow velocityis generally measuredwith a magnehelic gaugeand a pitot tube.• To avoid airflow turbulenceand incorrect readings, theairflow velocity should bemeasured on steel ductinga minimum of 3 ductcross-section from the unitor elbow and before anytransition.• The balancing procedure consists of measuring the exhaust air leaving the system and the supply air entering the system and ensuring that these two are equal. A deviation of 10% or less is acceptable.AIR FLOW BALANCINGA professional air balancer should be contacted to commission the system properly. A skilled HVAC Tech may complete the bal-ance of air providing they possess the proper equipment. Call Fantech Technical support for assistance.Exhaust Air ductingThe stale air exhaust system is used to draw air from the points in the building where the worst air quality problems occur. ( See installation examples in the manual.)Installing ducts to / from insideDirect Connection to Furnace/ Air handler return duct• Should you wish to hard duct the supply air directly into the cold air return of the HVAC systems, remember to check the airflow balance of the HRV with the HVAC systems fan both “on”and “off” to determine that it does not imbalance the HRV more than 10%. Make sure you respect the minimum distance from the supply air in of the HRV and the HVAC systems.• I t may be necessary to install a separate fresh air supply ductwork system if the heating is other than forced air.When installing an HRV, the designer and installer should be aware of local codes that may require smoke detectors and/or firestats in the HVAC or HRV ductwork.Because an HRV is designed to bring fresh air into the building, structures may require supply voltage interrupt when smoke or flame sensors are triggered, or when a central fire alarm system is activated.To maximize airflow in the ductwork system, all ducts should be kept short and have as few bends or elbows as possible. Forty-five degree are preferred to 90Þ elbows. Use “Y” tees instead of 90Þ elbows whenever possible.All duct joints must be fastened with screws or duct sealant and wrapped with a quality duct tape to prevent leakage. Aluminum foil duct tape is recommended.SUPPLY AIR DUCTINGIn buildings without a forced air HVAC systems, fresh air should be supplied to all habitable areas. It should be supplied from high wall or ceiling locations. The grilles that are to be used should be designed to properly and comfortably sweep cold surfaces.Optional inline duct heaters may be used to add heat if required. Typically the reheat is best done using a coil off the same boiler that heats the pool water.9fantechInstallation examplesInstalling BYPASS Module (BPM)Refer to BPM Installation, Operation and Maintenance documentfor InstructionsEXTERIOR WALLEXTERIOR WALLEXTERIOR WALLEXTERIOR WALLInstallation with Grille10fantech1. Continuous / Ventilation ModeIn this mode of operation, both fans are operating and exchanging air with the outside. The heat recovery ventilator (HRV) constantly exchanges the air at the rate you select, either at low or medium speed, and switches to high speed when activated by an optional remote control. The "Low" and "Med" fan speed selection will cause the unit to operate in continuous exchange mode at a reduce exchange rate. Continuous mode is recommended, since pollutants are slowly but constantly being generated in a building. 2. Recirculation ModeIn recirculation mode, the supply motor continues to run and a damper moves to block off air entering from outside, drawing air instead from the conditioned space. The exhaust to outside motor is OFF when in recirculation mode.3. Intermittent / Standby ModeThe system is always on standby and operates at high speed when activated by an optional remote control (required): "Standby" should be selected if the user wishes to stop the unit from continuous exchange.4. Defrost by RecirculationA preset defrost sequence is activated at an outdoor air temperature of -5ºC (23ºF) and lower .During the defrost sequence, the motorized damper in the bypass module (BPM) temporarily blocks the incoming fresh air stream so that the warm air from the room can circulate through the HRV. The exhaust blower shuts down and the supply blower switches into high speed to maximize the effectiveness of the defrost strategy. During this cycle, the unit will not create a negative pressure. Please note that these systems are configured to defrost with the BPM devices installed on the fresh air from outside port. Alternate configuration are available by contacting our technical support department.Modes of operationThe ERV is shipped from the factory on low speed, intermittent operation can be obtained by toggling switch located on outside of cabinet. External low voltage contacts allow for high speed operation when optional remote control is used.Setting speed11fantechLow Voltage Control Systems* Please see instruction manuals for individual controls for proper wiring and set up of control systems.CENTRAL CONTROLS –These control options can only be used individuallyCONTROLS FEATURESCONNECT TOECO-Touch• Our most complete, yet easy to use control system • Sleek design with backlight touchscreen LCD• ECO mode selects the best operating mode and speed for the season, minimizing energy use associated with ventilation • Set preferred indoor relative humidity range and ventilation mode for day and night conditions• No battery to replace, all programmed settings are retained during power outage• Maintenance reminder indicator• Error code messages reduce troubleshooting time EDF7• MODE button provides 3 modes of operations: Ventilation , Recirculation and Standby• User selected fan speed: Low, Medium, Normal and 20 minutes per hour• AUTO setting allows the homeowner to deactivate the dehumidistat• When the humidity exceeds the desired setpoint, the venti-lation system operates at Normal speed.• Once the desired humidity level is achieved, your ventilation system resumes to its previous mode of operation EDF1R• Press button once for continuous LOW speed• Press button twice and the unit will cycle 20 minutes ON/ 40 minutes OFF and repeat• Press button a third time and the system will run recircula-tion on HIGH speedRTS2**Maintain polarity between control and HRV(+→ + ; - → -)EDF EDFEDF EDFEDF EDF12fantechMaintenanceThe filters need to be checked and cleaned once a month or when they appear dirty.FILTERSThe motor - The motors are factory balanced and lubricated for life. They require no maintenance.The unit - The inside of the unit should be wiped clean as needed.Condensation Pan - Units with drain hoses should have their line and connection checked regularly.Outside hoods - The outside hoods need to be checked every season to make sure there are no leaves or insects blocking the airflow. Check regularly that there are no pollutants near the intake hood. Make sure they are clear of any snow accumulation during the winter months.Clean cores on a average every 3-6 months or as needed. a) Open access door & remove filters.b) C arefully pull on handle of core and pull evenly outward. Coresmay be snug, but will slide out of the channel.c) Wash the cores in warm soapy water or light coil solution.d) Install clean cores making sure the matting surfaces haveone sealing edges between each cores to minimize leaks.e) Install the clean filters f) Replace access doorNote : Core installation label on the outer end of the core.To install the clean Core and Filters.a) First mount the bottom flange of the core guide into thebottom channel approximately 6mm (1/4")b) Mount the left or right side flange of the core guideapproximately 6mm (1/4") followed by the other side c) Mount the top flange of the core guide into the topchannel approximately 6mm (1/4")d) With all four corners in place and the core straight and even,push hard in the centre of the core until the core stops onthe back of the cabinet.CAUTION MAKE SURE UNIT IS UNPLUGGED BEFORE ATTEMPTING ANY MAINTENANCE WORKThe following components should also be inspected regularly and well maintained.FIXED PLATE13 Wiring diagram SHR 8005R and SHR 14105Rfantech14fantechSHR 8005R, SHR 14105R Models Without External Control1. Fan speed selector switch• Set fan Speed selector switch to Standby.2. Start-up• Apply power to unit• Unit should enter Recirculation mode for a 30 second duration and the following should occur:3. Standby• Following the start-up unit should enter Standby mode. The following should occur:4. LOW speed• Set fans speed selector switch low speed. The following should occur.5. Medium speed• Set fans speed selector switch MED speed. The following should occur.6. Test completion• Set fan speed selector switch to desired setting • Installation Verification test is completeWith external control1. Start-up• Apply power to unit• Unit should enter Recirculation mode for a 30 second duration and the following should occur:2. External control• Following start-up unit will respond to external control• Consult user manual/instruction provided with external controller and ensure unit responds appropriately.3. Test completion• Installation Verification test is completeInstallation Verification Test15 L imited Warranty• The heat recovery aluminum core has a lifetime warranty. Fantech offers a lifetime warranty on the heat recovery core when installed in high humidity applications such as indoor pools and spas. During its lifetime oxidation may occur on the surface of the plates which is considered normal and does not need replacing. Fantech limits defects to condensation leaks as a result of perforation due to corrosion caused by normal use.• Fantech HRV's have a warranty that is limited to 3 years on all parts from the date of purchase, including parts replaced during this time period. If there is no proof of purchase available, the date associated with the serial number will be used for the beginning of the warranty period.• The motors found in all Fantech HRVs require no lubrication, and are factory balanced to prevent vibration and promote silent operation.• The limited warranty covers normal use. It does not apply to any defects, malfunctions or failures as a result of improper installation, abuse, mishandling, misapplication, fortuitous occurrence or any other circumstances outside Fantech’s control.• Inappropriate installation or maintenance may result in the cancellation of the warranty.• Any unauthorized work will result in the cancellation of the warranty.• Fantech is not responsible for any incidental or consequential damages incurred in the use of the ventilation system.• Fantech is not responsible for providing an authorized service centre near the purchaser or in the general area.• Fantech reserves the right to supply refurbished parts as replacements.• Transportation, removal and installation fees are the responsibility of the purchaser.• The purchaser is responsible for adhering to all codes in effect in his area.* This warranty is the exclusive and only warranty in effect relative to the ventilation system and all other warranties either expressed or implied are invalid.fantechFantech reserves the right to make technical changes.For updated documentation please refer to Fantech®fantech。
ATT7025/7027单口编程器使用手册Tel: 021-********Fax: 021-********Email: sales@ Web: 目录1概述 (4)2适用范围 (4)3单口编程器配件 (4)4单口编程器功能 (4)5单口编程器硬件示意图 (4)6单口编程器原理框图 (5)7联机模式操作规程 (5)7.1硬件连接 (5)7.2PC端软件外观 (5)7.3操作流程(具体请看后面的图示说明) (6)7.4详细操作图示说明 (6)8脱机模式操作规程 (11)9编程中会出现的错误 (11)9.1第一类错误情况 (11)9.2第二类错误情况 (11)1概述单口编程器是针对ATT7025 / 7027在量产的时候编程使用的工具,电脑通过串口将用户需要下载的程序以及校验和传送到编程器内主控芯片的外部Flash中,当用户将需要烧写的目标芯片放入socket内的时候,通过点击编程器面板的红色按钮或者使用软件中的相应按钮,主控芯片会将其外部Flash中的数据烧写到目标芯片中,并计算校验和与之前存在主控芯片外部flash的数据比较,从而保证程序烧写的正确性。
2适用范围ATT7025 / 7027 系列芯片3单口编程器配件ATT7025/7027单口编程器硬件公-母串口连接线单口串行编程器软件单口串行编程器软件使用说明(在公司网站下载)AC-DC电源适配器:9V---12V4单口编程器功能支持使用PC对目标芯片编程支持脱机编程编程完成后自动校验5单口编程器硬件示意图6单口编程器原理框图7联机模式操作规程7.1 硬件连接将编程器与PC用串口线相互连接,接入AC-DC电源适配器,打开编程器电源,此时电源指示灯应该点亮,说明电源供电正常。
7.2 PC端软件外观(1) OpenPort ――― 打开串口(2) OpenFile ——― 打开一个Hex文件,以Bin文件的形式在左边窗口中显示(3) FlashErase ――― 擦除主控芯片的Flash(4) FlashWritten ――― 将要烧写的的程序内容写入主控芯片外挂的Flash内,同时会计算写入程序的校验码,并将其显示在Checksum1窗口,校验码是32K地址空间所有数据的累加和。
仪器定位使用前的检查1.仪器送达目的地卸车后首先目测检查仪器的外观、台面、开关、插座等在运输过程中有无损坏。
2.仪器通电前用万能表测量仪器插座L与N之间的电阻值大约 1.5KΩ,接地线(双色)分别与L、N之间应该“∽”,用万能表测量PLC24V+与公共端之间的阻值应该是750Ω左右。
3.目测检查高分断断路器、光耦等线路有无松动或脱落。
4.用万能表检查医院插座交流220V市电是否正常,三相插座左眼孔应是N,右眼孔应是L,上面中间眼孔应是接地孔(接地孔应与大地有充分联接)。
5.通电后打开侧面总电源开关,注意观察有无异常现象(如:有无电器烧焦的异味、打火等),过几秒钟后打开电脑,然后再打开前面不锈钢六鍵开关的交流220V、直流24V开关。
6.生理盐水储槽加生理盐水、染色剂储槽加染色剂。
7.加载玻片,取尿样杯加水后放到离心盘上。
8.打开界面开始调试仪器。
操作部分一、启动前准备工作1、检查电源线是否连接好;2、检查生理盐水、染色剂是否处在液位的有效位置(大约不低于储糟的1/2、1/3);3、检查罩壳内是否有异物;废物桶、管道的放置是否处在有效位置;4、检查玻片、打印纸是否准备充分;5、检查显微镜粗调位置是否处在图象显示的有效位置,即看一下显微镜的物镜是否低于移动盘的位置,若低的话稍微向上抬一点,以防止镜检盘旋转时碰到物镜。
二、启动1、打开仪器右侧方的总电源开关(警示:是否有异常情况,如焦味。
若有则停止对仪器的使用,检查主控电路。
)2、分别开启电脑,打印机及风扇开关。
3、依次打开220V和24V (220V控制离心盘、摄像头;24V控制机械手1、手2、玻片、镜检盘),打开仪器机盖。
三、样杯放置1、先给尿样杯依次编号,在其对应的化验单上也相应地编号,以防检验顺序错乱,造成检验错误。
把尿液倒入专用的尿样杯中,使其尿量10ml(即在样杯液位标记处)误差保证在±0.2ml。
2、把尿样杯放入离心盘,为保持离心盘的平衡,尿样杯必须对称放置。
系统默认从1号杯位开始做起,若有偶数个样本则对称放置,若有奇数个样本则在相应位置加一个内装水四、操作1、软件的启动与复位(1)启动软件在桌面上双击QS8005图标,即可启动本软件同时进入操作界面,如图(1)(图1)(2)复位系统在操作区中点击“复位”按纽,此时机械手和镜检盘自动复位。
(如图2)(图2)(3)启动系统初始化系统完成后,在操作区中点击“启动”按钮,弹出“离心标本数量输入”对话框,如(图3)。
输入此次检验的样本数量(默认值为12),点击“确定”按钮开始离心,离心进度条显示离心进度,如(图4)。
(离心时间3min,离心转数1540r/min)离心时间和离心速度都符合国家卫生部组织标准规定。
(图3)(图4)(3)当离心结束后,离心盘自动将1号标本定位到吸尿清位置,1号机械手也同时转到吸尿清的位置。
2、吸取尿上清液、滴加染色剂、吹气混匀、吸沉渣、滴加尿样、镜检(1)1号机械手自动向下吸取1号标本的尿上清液,并留下约0.5ml的尿沉渣;(2)1号机械手自动向上复位;(3)离心盘自动旋转使1号标本到达滴染色剂处,手1自动滴一滴染色剂(25ul);(4)离心盘旋转到2号机械手吸沉渣处;(5)2号机械手自动旋转到取尿样处,同时镜检盘也自动加载一片玻片后旋转到滴沉渣处;(6)2号机械手自动向下吹气、混匀1号标本,吸取沉渣、抓取尿样杯;(7)2号机械手自动转到丢杯处将尿杯丢至废物桶中,此过程中离心盘自动转到下一个样本,重复手1的动作;(8)2号机械手旋转至滴沉渣处,自动向玻片池中滴加1号标本的沉渣(20ul);(9)2号机械手自动转至清洗处,自动向下吸取生理盐水以清洗管道内的残余沉渣(为防止交叉感染,每做完一例标本,都要进行清洗);(10)2号机械手自动向上复位;(11)仪器按照以上步骤自动完成12个标本的吸取尿上清液、滴加染色剂、吹气混匀、吸取尿沉渣、自动扔杯、滴加尿样、清洗的过程;(12)当所有的标本取样结束,且标本染色3分钟时间到之后,镜检盘自动旋转到显微镜下面进行调焦、镜检、摄像(此时可将风扇暂时关闭,以防拍图时图像抖动)。
注1:手动调焦情况下:一般先点“快速下调”或“快速上调”进行粗调,使之到达细胞层;再点“上调”或“下调”进行初次微调,再点“上一步”或“下一步”进行再次微调,如果当前视野图像不清晰,可点击“前进”换下一个视野,总共有6个视野可供选择(待到图像调到完全清晰后可点“抓图”,仪器会自动抓取10幅图像并保存);通过物镜和高精度模拟摄像头将细胞的形态、大小、数量清晰地反映到电脑显示屏上,在反映到电脑显示屏的细胞已放大1120倍,在这同时细胞识别软件开始对每个标本所拍的10幅图进行自动分析,并自动打印报告单(系统默认打印所拍10幅图中的第一幅)。
反映到电脑显示屏上的细胞,无需人工识别和点数。
当您对分析结果有疑问时,请再重新打开其标本所拍的10幅图,看分析结果是否正确;注2:“快速上调”和“快速下调”,“上调”和“下调”点一下则一直在工作(此时显微镜处的灯亮),再点一下时则停止工作(此时灯不亮);“上一步”和“下一步”点一下则工作一下,当“快速下调”和“下调”到一定位置时灯不再亮,证明不能再往下调了,此时可以点“快速上调”或“上调”来继续调焦、抓图。
(如图5)(图5)(13)镜检盘自动丢弃已镜检的玻片,并自动按照以上步骤对下一个标本进行镜检摄像,直到完成所有的标本;(14)单独调焦镜检时请将待检样本放到物镜下,点击“单独检查”,即可开始调焦拍图。
(注:如果有几例标本需单独调焦镜检,后面的样本需隔一个位置放置)。
3、基本资料的输入和修改(1)点击界面中的“基本资料输入”按钮,输入病员的基本资料(如图6),输入完毕后点击“添加记录”或是按回车键,资料即可保存并自动转入下一个,即可直接输入病员的基本资料(注:在离心过程中,为节省时间,即可对病员的基本资料进行输入)。
(图6)(2)如需修改某项记录,可先点击“基本资料输入”,找到所要修改的记录,修改完毕后点击“修改记录”即可。
(3)如需修改检验结果,可先点击“数据查询”,找到所要修改的记录,(其中管型和上皮细胞只能显示3种,结晶、细菌、滴虫、精子计数需手动输入)修改完毕后点击“退出”即可。
4、病员尿沉渣分析信息的操作(1)数据显示:界面中的数据栏可显示病员实时数据,并显示当前数据为第几条数据,按“向前一个记录”或“向后一个记录”,可显示当前记录的前一个或是后一个记录。
(2)实时数据查询(可查询当天所做的相关数据):点击菜单栏上的“数据查询”——>“实时数据查询”(或是直接点击界面上的按钮“数据查询”),弹出实时数据查询对话框,选择查询方法(病历号、样本、姓名)并输入关键字,点击“查询”按钮即可,双击查询所得记录可跳出对话框,显示该记录的详细信息。
(3)历史数据查询(可查询当天以前所做的标本):点击“历史数据查询”,弹出历史数据查询对话框,选择查询方法(病历号、姓名)及输入关键字,点击“查询”按钮即可,双击查询所得记录可跳出对话框,显示该记录的详细信息。
(如图7)(图7)(4)病员尿沉渣信息分析报告的打印a)若病员的基本资料输入完成,镜检结果已分析完毕后,且系统设置中已设置为自动打印,电脑则自动打印报告单。
b)如果想对特定某个病员的信息进行打印,查询找到此病员的信息,然后点击“报表单个打印”按钮(系统默认打印第一幅图片);若第一幅图片不清晰,可点击“前一幅图”或“后一幅图”来选择较满意的一幅图片进行打印(并点击“保存”按钮即可)。
5、图片查询(1) 当天所做标本的图片查询点击“我的电脑”——>“本地磁盘(D:)”——>“picture”,可查看当天所做的每个标本的10幅图片;(2) 历史图片查询点击“我的电脑”——>“本地磁盘(D:)”——>“historypicture”,可查看今天以前所做标本的图片(每个标本只有1幅图片,系统默认保存每个标本的第一幅图片),数据库可存50万例。
6、界面“系统设置”中,可设置是否自动打印、自动扔杯,系统自动调焦(如图8)(图8)7、退出(1)点击“退出系统”按钮或是关闭QS8005界面;(2)关闭计算机、打印机;(3)依次关掉24V和220V电源;(4)关掉整机电源。
五、保养1、每天关机前需清洗一次两个机械手(点击界面中“系统控制”——>“机械手1清洗”——>“清洗结束”、“机械手2清洗”——>“清洗结束”)2、关机后及时用酒精棉擦洗仪器表面、吸液(渣)针管、光电开关等;3、生理盐水清洗杯不能用酒精擦洗,可用干酒精棉擦拭;4、每天要倒空废物桶并检查管道的放入;5、每周擦拭一次显微镜、摄像头等。
六、注意事项1、确定供电系统使用的电压稳定,电源线完好无损;2、添加玻片时必须孔位向上;3、离心杯必须平衡放置于离心盘上;4、仪器运行时,严禁将手或其他物体伸入机内,确保机内无异物,离心时禁止打开机盖;5、离心时不能关掉电源,防止发生离心故障,打碎杯子;若离心时突然断电,先关掉220V开关,再关掉24V;若点击离心后,发现220V未打开,应先关掉24V,再依次打开220V、24V;6、启动前必须检查生理盐水、染色剂、玻片、打印纸是否准备充分;废物桶放置是否到位,管道是否处于有效位置;7、使用后的废弃玻片、尿样杯等应及时清理,避免污染;8、电脑必须正常打开和关闭,软件必须正常退出;9、异常情况下必须检查系统状态,必要时重新启动系统;10、关机时,必须先关掉电脑、打印机的电源,随后关掉24V和220V电源,最后再关掉整机电源;11、紧急情况下,操作人员应及时切断电源。
机械部分一、仪器机械部分组成(如图一)QS8005尿沉渣分析仪是由1、台板2、吸尿清机械手3、离心盘机构、4、吸沉渣机械手5、镜检盘6、摄像头7、生理盐水储槽及染色液储槽8、摄像机构9、玻片机构(图一)1.吸尿清机械手(如图二)吸尿清机械手是由步进电机控制,可以左右旋转并上下升降运动。
主要功能:a.从尿样杯中吸取尿清液;b.从染色剂储槽中吸取染色剂并定量加入到尿样杯中;组成结构:直线电机、丝杠支架、吸尿清管、加染色剂悬臂、染色剂光电开关等作用:a.吸取尿上清液,保证沉渣剩余量约为0.5mlb.滴加染色剂( 图二)2.离心盘机构(如图三)QS8005仪器上有一个离心盘,离心盘上带有12个尿样杯套。
(如图三)主要性能:对尿样进行智能编号、高速离心尿中有形成分。
分离后尿沉渣细胞形态完整,定量准确,离心力可控制、噪音小。
组成结构:离心盘、杯套、伺服驱动器、伺服电机等。
作用:自动编号、分离尿有形成分等(图三)3.吸沉渣机械手(如图四)吸沉渣机械手是由步进电机控制,可以左右旋转并上下升降运动主要功能:a.向尿样杯中吹入气体使染色剂与尿沉渣充分混匀;b.从尿样杯中吸取尿沉渣;c.抓取尿样杯并丢入废物桶;d.向载玻片定量滴加尿沉渣;e.吸入生理盐水对滴沉渣管进行冲洗组成结构:直线电机、丝杠支架、吸尿清管、加染色剂悬臂、染色剂光电开关等作用:吹气混匀尿沉渣并吸取足量尿沉渣,并向玻片计数池滴加一滴尿沉渣(图四)4.镜检摄像机构(如图五镜检摄像装置示意图)主要性能:自动加载计数池、定量取样定位;自动调焦显微、高速摄像,图像清晰;自动丢弃一次性计数池并复位。