ET5120
- 格式:pdf
- 大小:586.67 KB
- 文档页数:9
FULL FEATURED AC/DC TIG SYSTEMS.®BUILT TOUGH FOR EXTREME USAGE. LIGHT& PORTABLE.the ESAB® Et 220i Ac/dc and Et 301i Ac/dc are high output, full digital control, Ac/dc, Stick/Lift tIG/HF tIG inverter power supplies with expanded input voltage capabilities for maximum flexibility. Standard features include: High frequency start,Lift tIG start, automatic downslope, pulse, repeat (latch) function, memory function and automatic gas management. the Et Ac/dc power supplies provide the ultimate in precision tIG and Stick welding for ferrous and non-ferrous metals.ADVANCEDn Inverter t echnologyEmbedded microprocessor with digital controls delivers ultimate performance and perfect welding characteristics.n tiptronic Memory FunctionStore up to 100 exact optimized welding parameters then digitally recall them with perfect repeatability.n Automatic Input Voltage SelectionOperates on 208-230/460V Single or Three Phase.n Robust caseCrash proof with protection at 9 individual crash points. n Highly PortableCompact size and light weight ensure a small workspace footprint and job site portability.CONTROLS.Parameter Scroll ButtonsDepress button to scroll through available welding parametersWelding Type FunctionDepress to change type:HF TIG, Lift TIG, Output + or -, AC or DC outputTiptronic Save/Load ButtonsSaves up to 100 welding programsSimple to use Operator InterfaceScrolls through selections for parameter valuesMulti-Function ControlAdjusts available process parametersGas Purge ButtonEnsures gas lines are purged at start of weldWelding Mode FunctionSelects welding process mode. GTAW 2T, GTAW 4T, GTAW Spot, GTAW Pulse, Tiptronic, SMAWFEATURES.Digital MetersDisplays both the pre-set current and actual output current of the power source. Also displays Welding Parameter Codes.Output Terminals50 mm Dinse welding output terminals with polarity reversal capabilityExtreme DurabilityStainless Steel Handle, Heavy-Duty Base Plate and Strong Feet built toughIP23S Approved DesignSuitable for outdoor useRecessed Front PanelProtects multi-function knob and controls8 Pin Remote ReceptacleEasy to connect to remote controlsAPPLICATIONS.The ESAB ET AC/DC range of inverter welding power supplies deliver outstanding arc characteristics thanks to advanced embedded microprocessor technology and digital control.Market-leading features combined with a compact, portable inverter design and a full range of packaged accessories address the needs of the growing aluminum and stainless steel fabrication and repair and maintenance sectors. ESAB ET power supplies meet the rigorous demands of a broad scope of welding applications:n G eneral Aluminum and Stainless SteelFabricationn Stainless Steel Tank and Pipe Fabricationn Boat Building / Shipyardsn Automotive Components and Repairsn Technical Schoolsn Custom Job Shopsn Aerospacen A pplications Requiring Stringent WeldingProcedure AdherenceMACHINE FEATURES.n Ac and dc output for aluminum and non-ferrous alloys, stainless, mild steel and chrome molys.n Process selection between tIG or Stick.n Ac Frequency: Adjustable frequency of the AC square wave when welding aluminum for optimized set up.n Wave Balance: Adjustable for optimized penetration or cleaning action when welding aluminum.n tIG Pulser: Changes the weld current from high to low at a specified frequency, reduces heat input on thin material.n Rapid Pulse: Focus the arc, increase amperage, run faster and shrink the heat-affected zone – all while maintaining excellent penetration.n Preflow & Postflow: Enables independent control over shielding gas before and after the weld.n tIG Sloper / Initial current / Upslope / downslope & crater modes: Eliminates blow holes on starting and cracking at the end of the weld.n HF Arc Start: Provides non-contact arc starting that eliminates tungsten or material contamination.n trigger Hold: 4T (Latch) eliminates operator fatigue.n Lift tIG Start: Provides optimized TIG arc starting without the use of high frequency.n digital Meters: Voltage and Amperage; Preview and hold capability for easy set up.n Remote Receptacle Fitted: Allows remote devicesto be connected for controlling amperage and output contactor.n tungsten Size: Select tungsten size for optimum starting performance.n Spot Mode: Enables timer functions for consistent spot welds.n thermal Overload Protection: Alerts the operator if the duty cycle is exceeded or airflow is blocked. Shuts down the power source to protect the internal electrical components from overheating.n Excellent MMA (Stick) Welding: Hot start, anti-stick and arc force regulation allow the operator to achieve excellent MMA welding results.n Intelligent Heat Sensing Fan: Operates as needed to cool components and reduce airborne contaminants pulled through the power source.Et 220i AC/DCHF tIG Inverter Power SourcePart No. W1009300nEt 220i Ac/dc HF tIG Inverter Power Source includes two 50 mm Dinse Adapters and DVD with Quick Start Guide & Operating ManualEt 220i AC/DCtIG torch trolley PackagePart No. W1009302nIncludes Et 220i Ac/dc HF tIG Inverter (W1009300)PLUSnRunning Gear/cylinder Rack trolley n 200 Amp 15 ft (4.6 m) tIG t orch n Electrode Holder & Lead n Ground clamp & Leadn Victor Flowgauge/Regulator n Gas Hosen 15 ft (4.6 m) Foot controlEt 220i AC/DCtIG t orch PackagePart No. W1009301nIncludes Et 220i Ac/dc HF tIG Inverter (W1009300)PLUSn200 Amp 15 ft (4.6 m) tIG t orch n Electrode Holder & Lead n Ground clamp & Leadn Victor Flowgauge/Regulator n Gas Hosen 15 ft (4.6 m) Foot controlSYSTEM PACkAGES.Et 301i AC/DCHF tIG Inverter Power SourcePart No. W1009400n Et 301i Ac/dc HF tIG Inverter Power Sourceincludes two 50 mm Dinse Adapters and DVDwith Quick Start Guide & Operating ManualEt 301i AC/DCWater cooled tIG SystemPart No. W1009401n Includes Et 301i Ac/dc HF tIG Inverter (W1009400)PLUSn coolant Recirculator and Interface cablen Running Gear/cylinder Rack trolleyn 300 Amp 25 ft (7.6 m) Water cooled tIG t orchn Electrode Holder & Leadn Ground clamp & Leadn Victor Flowgauge/Regulatorn Gas Hosen 15 ft (4.6 m) Foot controltIG t orchPARt NO. W4013600TIG T orch 26 w/Hand Remotes, 12.5 ft (3.8 m), 50 mm & Accessory KitWater cooled tIG t orchPARt NO. W4013604TIG T orch 25 ft (7.6 m), Water Cooled with Accessoriest weco Electrode HolderPARt NO. 9110-1177T weco 200 Amp Electrode Holder & Lead Accessory, 13 ft (4 m) Length, 50 mm Dinset weco Ground clampPARt NO. 9255-1140T weco 200 Amp Ground Clamp & Lead Accessory, 10 ft (3 m) Length, 50 mm DinseVictor Flowgauge RegulatorPARt NO. 0781-5120Victor ESS3-RG-580 EDGE Argon Flowgauge RegulatorGas HosePARt NO. W4013900Gas Hose, 12.5 ft (3.8 m) Length, Male 5/8"-18unf gas fittingsFoot controlPARt NO. 600285Foot Control Contactor On/Off& Current Control w/8-pin Male Plug & 15 ft (4.6 m) CableFoot controlPARt NO. 10-4016Foot Control Contactor On/Off& Current Control w/8-pin Male Plug & 25 ft (7.6 m) CableHand PendantPARt NO. 10-4014HP-100 Hand Held Remote Control PenantWater RecirculatorPARt NO. W4001303110VAC Water RecirculatorInterface cablePARt NO. W4001350Water Recirculator to power supply interface cableIndustrial trolley cartPARt NO. W4010003Running Gear / Cylinder Rack Trolley Cart holds ESAB power source, water recirculator and accessoriesdinse connectorPARt NO. 9425-1431Dinse Male Connector 50 mmt orch Mounted contactorsPARt NO. 10-4006T orch Mounted Contactor On/Off w/8-pin Male Plug & 15 ft (4.6 m) CablePARt NO. 10-4007T orch Mounted Contactor On/Off w/8-pin Male Plug & 25 ft (7.6 m) CablePARt NO. 10-4008T orch Mounted Contactor On/Off & Current Control w/8-pin Male Plug & 15 ft (4.6 m) Cable, Fits CK9 Style HandlePARt NO. 10-4009T orch Mounted Contactor On/Off & Current Control w/8-pin Male Plug & 15 ft (4.6 m) Cable, Fits CK17 Style HandlePARt NO. 10-4010T orch Mounted Contactor On/Off & Current Control w/8-pin Male Plug & 15 ft (4.6 m) Cable, Fits CK26 Style HandlePARt NO. 10-4011T orch Mounted Contactor On/Off & Current Control w/8-pin Male Plug & 25 ft (7.6 m) Cable, Fits CK9 Style HandlePARt NO. 10-4012T orch Mounted Contactor On/Off & Current Control w/8-pin Male Plug & 25 ft (7.6 m)) Cable, Fits CK17 Style HandlePARt NO. 10-4013T orch Mounted Contactor On/Off & Current Control w/8-pin Male Plug & 25 ft (7.6 m) Cable, Fits CK26 Style HandlePARt NO. 600296T orch Mounted Rotary ContactorOn/Off & Amperage Control 5k w/8-Pin Plug & 15 ft (4.6 m) Cable for TD8PARt NO. 600297T orch Mounted Rotary ContactorOn/Off & Amperage Control 5k w/8-Pin Plug & 25 ft (7.6 m) Cable for TD8* Subject to change without noticeOPTIONS& ACCESSORIES11UNRIVALED SERvICEAnD SUPPORT.ET AC/DC power supplies, like all ESAB products, are backed by our commitment to superior customer service and support. Our skilled customer service department is prepared to quickly answer any questions, address problems, and help with the maintenance and upgrading of your machines. And our products are backed with the most comprehensive warranty in the business.With ESAB, you can be sure you purchased a machine that will meet your needs today and in the future. Product and process training is also available. Ask your ESAB sales representative or distributor for acomplete ESAB solution.For more information visit .3-Year Warranty.ESAB’s industry-leading service and support means that if you do need help, you’ll beprotected by the most comprehensive warranty in the business.ESAB/ARC-23318 6/15©2015 ESAB Printed in U.S.。
SUN T5120服务器创建RAID并安装solaris 10系统安装手册由于业务需要,公司买了一台sun T5120服务器,不过打开一看,里面并没有直接接显示器的接口,而且必须通过转换器进行转换,转换后也是无法显示,上官网查了一下,需要通过它的ser mrt接口来连接。
它的ser mrt接口是rj45的,sun提供一个rj45到串口的转换器。
第一部分、服务器启动:1、用串行电缆连接终端设备(笔记本)和服务器的SER MGT端口,以9600波特、8位、无奇偶校验、1个停止位的方式通信。
2、插上电源,此时SP (service processor, SP)会进行初始化,电源LED灯亮起,可在终端看到初始化过程,几分钟后终端上出现SP登陆提示符。
此时主机尚未接通电源和初始化。
3、在终端上以root/changeme登陆到SP,显示ILOM提示符->。
SUNSP00144FAC732F login:rootPassword:changeme。
->此时ILOM固件运作并以默认ILOMshell方式与SP通信(或ILOM浏览器界面或ALOM CMT兼容shell 方式,ALOM CMT兼容shell方式适用于诊断和修复操作),可以使用ILOM命令。
ILOM2.0固件(无人值守管理系统)安装在SP模块上提供硬件与系统地接口。
4、创建ALOM CMT兼容shell方式的用户,名为admin/密码admin,账户角色设置为Administrator,将CLI模式设置为alom->create /SP/users/admin role=Administrator cli_mode=alomEnter new password:*******Enter new password again:*******Created /SP/users/admin完成后可以退出登陆,在SP登陆提示符下以admin用户名登陆,显示sc>提示符。
Eaton 265721Eaton Moeller series NZM - Molded Case Circuit Breaker. Circuit-breaker, 3p, 80A, N1-M80General specificationsEaton Moeller series NZM molded case circuit breaker thermo-magnetic265721NZMN1-M80401508265721588 mm 145 mm 90 mm 1.021 kg RoHS conformIEC IEC/EN 60947Product NameCatalog NumberModel Code EANProduct Length/Depth Product Height Product Width Product Weight Compliances Certifications80 AIs the panel builder's responsibility. The specifications for the switchgear must be observed.7.5 kA35 kAMeets the product standard's requirements.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Built-in device fixed built-in techniqueFixed80 ADoes not apply, since the entire switchgear needs to be evaluated.Min. 2 segments of 9 mm x 0.8 mm at box terminalMax. 9 segments of 9 mm x 0.8 mm at box terminalRocker leverMeets the product standard's requirements.40 °CThermal protectionFinger and back-of-hand proof to VDE 0106 part 100eaton-feerum-the-whole-grain-solution-success-story-en-us.pdfeaton-digital-nzm-brochure-br013003en-en-us.pdfeaton-digital-nzm-catalog-ca013003en-en-us.pdfDA-DC-03_N1eaton-circuit-breaker-nzm-mccb-characteristic-curve.epseaton-circuit-breaker-let-through-current-nzm-mccb-characteristic-curve-002.epseaton-circuit-breaker-nzm-mccb-characteristic-curve-058.epseaton-circuit-breaker-switch-nzm-mccb-dimensions-014.epseaton-circuit-breaker-nzm-mccb-dimensions-017.epseaton-general-ie-ready-dilm-contactor-standards.epsMN1-M80eaton-circuit-breakers-nzm-pn1-nzmbc-nzmbn-circuit-breaker-switch-disconnector-instruction-leaflet-il01203004z.pdfThe new digital NZM RangeIntroduction of the new digital circuit breaker NZMDA-CS-nzm1_3pDA-CD-nzm1_3peaton-nzm-technical-information-sheeteaton-manual-motor-starters-starter-msc-r-reversing-starter-wiring-diagram.epseaton-manual-motor-starters-starter-nzm-mccb-wiring-diagram.epsRated operational current for specified heat dissipation (In) 10.11 Short-circuit ratingRated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 HzRated short-circuit breaking capacity Icu (IEC/EN 60947) at 400/415 V, 50/60 Hz10.4 Clearances and creepage distances10.12 Electromagnetic compatibilityMounting MethodAmperage Rating10.2.5 LiftingTerminal capacity (copper strip)Handle type10.2.3.1 Verification of thermal stability of enclosuresAmbient storage temperature - minFitted with:Protection against direct contact BrochuresCatalogs Certification reports Characteristic curveDrawingseCAD model Installation instructions Installation videos mCAD model Technical data sheets Wiring diagramsTerminal capacity (copper busbar)Min. 12 mm x 5 mm direct at switch rear-side connection M6 at rear-side screw connectionMax. 16 mm x 5 mm direct at switch rear-side connection10.8 Connections for external conductorsIs the panel builder's responsibility.Special featuresMaximum back-up fuse, ifthe expected short-circuitcurrents at the installationlocation exceed theswitching capacity of thecircuit breaker (Rated short-circuit breaking capacity Icn)Rated current = rateduninterrupted current: 80 ATerminal capacity hint: Up to95 mm² can be connecteddepending on the cablemanufacturer.With phase-failure sensitivityTripping class 10 AIEC/EN 60947-4-1, IEC/EN60947-2The circuit-breaker fulfills allrequirements for AC-3switching category.Ambient operating temperature - max70 °CClimatic proofingDamp heat, constant, to IEC 60068-2-78Damp heat, cyclic, to IEC 60068-2-30Terminal capacity (aluminum stranded conductor/cable)25 mm² - 35 mm² (2x) direct at switch rear-side connection 25 mm² - 95 mm² (1x) at tunnel terminal25 mm² - 35 mm² (1x) direct at switch rear-side connectionTerminal capacity (copper stranded conductor/cable)6 mm² - 25 mm² (2x) at box terminal10 mm² - 70 mm² (1x) at box terminal10 mm² - 70 mm² (1x) direct at switch rear-side connection 25 mm² - 95 mm² (1x) at 1-hole tunnel terminal25 mm² (2x) direct at switch rear-side connection Lifespan, electrical7500 operations at 415 V AC-310000 operations at 400 V AC-17500 operations at 690 V AC-110000 operations at 415 V AC-15000 operations at 690 V AC-37500 operations at 400 V AC-3Electrical connection type of main circuitOtherShort-circuit total breaktime< 10 msRated impulse withstand voltage (Uimp) at main contacts6000 VRated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz35 kA10.9.3 Impulse withstand voltageIs the panel builder's responsibility.Utilization categoryA (IEC/EN 60947-2)Number of polesThree-poleAmbient operating temperature - min-25 °C10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.Terminal capacity (control cable)0.75 mm² - 1.5 mm² (2x)0.75 mm² - 2.5 mm² (1x)Equipment heat dissipation, current-dependent20.83 WInstantaneous current setting (Ii) - min640 A10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.Rated operational current68 A (400 V AC-3)Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz85 kAApplicationUse in unearthed supply systems at 690 V10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.Rated short-circuit making capacity Icm at 240 V, 50/60 Hz187 kARated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz35 kADegree of protection (IP), front sideIP66 (with door coupling rotary handle)IP40 (with insulating surround)Rated short-circuit making capacity Icm at 525 V, 50/60 Hz40 kARated short-circuit making capacity Icm at 690 V, 50/60 Hz17 kAInstantaneous current setting (Ii) - max1120 AOverload current setting (Ir) - min63 A10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.Lifespan, mechanical20000 operationsOverload current setting (Ir) - max80 AVoltage rating690 V - 690 VTerminal capacity (copper solid conductor/cable)10 mm² - 16 mm² (1x) direct at switch rear-side connection16 mm² (1x) at tunnel terminal10 mm² - 16 mm² (1x) at box terminal6 mm² - 16 mm² (2x) at box terminal6 mm² - 16 mm² (2x) direct at switch rear-side connectionDegree of protection (terminations)IP10 (tunnel terminal)IP00 (terminations, phase isolator and strip terminal)10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.Short-circuit release non-delayed setting - min640 ADegree of protectionIP20IP20 (basic degree of protection, in the operating controls area)Overvoltage categoryIIIRated impulse withstand voltage (Uimp) at auxiliary contacts 6000 VTerminal capacity (aluminum solid conductor/cable)10 mm² - 16 mm² (2x) direct at switch rear-side connection10 mm² - 16 mm² (1x) direct at switch rear-side connection16 mm² (1x) at tunnel terminalSwitch off techniqueThermomagneticAmbient storage temperature - max70 °CRated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz10 kAOptional terminalsConnection on rear. Screw terminal. Tunnel terminalRelease systemThermomagnetic releasePollution degree310.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.Rated operating power at AC-3, 230 V22 kW10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.FunctionsMotor protectionPhase failure sensitiveShort-circuit release non-delayed setting - max1120 AStandard terminalsBox terminalRated short-circuit making capacity Icm at 400/415 V, 50/60 Hz 105 kARated operating power at AC-3, 400 V45 kWTypeCircuit breaker10.2.2 Corrosion resistanceMeets the product standard's requirements.10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2.7 InscriptionsMeets the product standard's requirements.Rated short-circuit making capacity Icm at 440 V, 50/60 Hz74 kAIsolation300 V AC (between the auxiliary contacts)500 V AC (between auxiliary contacts and main contacts)Number of operations per hour - max120Circuit breaker frame typeNZM1Eaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaAs required 20 g (half-sinusoidal shock 20 ms)690 VDirection of incoming supply Shock resistanceRated insulation voltage (Ui)。
题目:锂电池充放电系统的设计所在院系:信息与通信技术系专业:电气工程及其自动化摘要随着电子技术的快速发展使得各种各样的电子产品都朝着便携化和小型轻量化的方向发展,也使得更多的电气化产品采用基于电池的供电系统。
目前为止,较多使用的电池有镍镉、镍氢、铅蓄电池和锂电池。
由于不同类型电池的充电特性不同,通常对不同类型,甚至不同电压、容量等级的电池使用不同的充电器,但这在实际使用中有很多不便。
本设计是一种基于单片机的锂离子电池充电器,在设计上,选择了简洁、高效的硬件,设计稳定可靠的软件,说明了系统的硬件组成,包括单片机电路、充电控制电路、电压转换及光耦隔离电路,并对充电器的核心器件MAX1898充电芯片、AT89C2051单片机进行了较详细的介绍。
阐述了系统的软硬件设计。
以C 语言为开发工具,进行了设计和编码。
保证了系统的可靠性、稳定性、安全性和经济性。
该充电器具有检测锂离子电池的状态;自动切换充电模式以满足充电电池的充电需求;充电器短路保护功能;充电状态显示的功能。
在生活中更好的维护了充电电池,使电池更好被运用到生活中。
关键词:单片机、MAX1898、AT89C51AbstractElectronic technology's fast development causes various electronic products develops toward portable and the small lightweight direction, It also causes the more electrification products to use based on battery's power supply system. At present, the many use's batteries have the nickel cadmium, the nickel hydrogen, the lead accumulator and the lithium battery. Their respective characteristic had decided they will coexist in a long time develop. Because the different type battery's charge characteristic is different, usually to different type, even different voltage, capacity rank battery use different battery charger, but this has many inconveniences in the actual use.This topic design is one kind lithium ion battery charger which is based on Single Chip, in the design, it has chosen succinctly, the highly effective hardware, the design stable reliable software, explained in detail system's hardware composition, including the monolithic integrated circuit electric circuit, the charge control electric circuit, the voltage transformation and the light pair isolating circuit, and to this battery charger's core component - MAX1898 charge chip, at89C2051 monolithic integrated circuit has carried on the detailed introduction. Elaborated system's software and hardware design. Take the C language as the development kit, has carried on the detailed design and the code. Has realized system's reliability, the stability, the security and the efficiency.The intelligence battery charger has the examination lithium ion battery's condition; The automatic cut over charge pattern meets when rechargeable battery's charge needs; Battery charger has short circuit protection function; The charge condition demonstration's function. The battery charger has made the better maintenance rechargeable battery in the life,and lengthened the rechargeable battery’s service life.Key words: SCM,STC89c51, MAX1898目录引言 (5)第1章绪论 (6)1.1课题研究的背景 (6)1.2课题研究的主要工作 (7)第2章电池的充电方法与充电控制技术 (9)2.1电池的充电方法和充电器 (11)2.1.1 电池的充电方法 (11)2.1.2 充电器的要求和结构 (15)2.1.3单片机控制的充电器的优点 (16)2.2充电控制技术 (16)2.2.1 快速充电器介绍 (16)2.2.2 快速充电终止控制方法 (17)第3章锂电池充电器硬件设计 (20)3.1单片机电路 (20)3.2电压转换及光耦隔离电路 (23)3.3电源电路 (24)3.4充电控制电路 (26)3.4.1MAX1898充电芯片 (26)3.4.2充电控制电路的实现 (30)第4章锂电池充电器软件设计 (32)4.1程序功能 (32)4.2主要变量说明 (32)4.3程序流程图 (32)结论与展望 (35)致谢 (35)参考文献 (36)附录A 电路原理图 (37)附录B 外文文献及其译文 (38)附录C 主要参考文献的题录及摘要 (40)附录D 主要源程序 (42)引言电池是通过能量转换获得电能的一种器件,电池可以分为一次电池与二次电池,一次电池是一次性的,二次电池可以反复循环使用。
浪潮英信服务器NE3120M5技术白皮书文档版本V1.4发布日期2022-12-01版权所有© 2022浪潮电子信息产业股份有限公司。
保留一切权利。
未经本公司事先书面许可,任何单位和个人不得以任何形式复制、传播本手册的部分或全部内容。
环境保护请将我方产品的包装物交废品收购站回收利用,以利于污染预防,共同营造绿色家园。
商标说明Inspur浪潮、Inspur、浪潮、英信是浪潮集团有限公司的注册商标。
本手册中提及的其他所有商标或注册商标,由各自的所有人拥有。
安全声明服务器产品安全一直是浪潮关注的焦点,保障产品安全是浪潮的关键战略之一。
为使您更清晰地了解服务器产品,请注意如下安全风险声明。
●在调整用途或淘汰服务器时,为了保护数据隐私,建议从BIOS、BMC中恢复固件出厂设置、删除信息、清除日志。
同时,建议采用第三方安全擦除工具对硬盘数据进行全面安全擦除。
●您购买的产品、服务或特性在业务运营或故障定位的过程中将可能获取或使用用户的某些个人数据(如告警邮件接收地址、IP地址),故您有义务根据所适用国家的法律制定必要的用户隐私政策并采取足够的措施,以确保用户的个人数据受到充分的保护。
●服务器开源软件声明的获取,请直接联系浪潮客户服务人员咨询。
●部分用于生产、装备、返厂检测维修的接口、命令,定位故障的高级命令,如使用不当,将可能导致设备异常或者业务中断,故不在本资料中说明。
如需要,请向浪潮申请。
●浪潮服务器的外部接口未使用私有协议进行通信。
●浪潮建立了产品安全漏洞应急和处理机制,保证第一时间及时处理产品安全问题。
若您在浪潮产品中发现任何安全问题,或者寻求有关产品安全漏洞的必要支持,可以直接联系浪潮客户服务人员。
浪潮将一如既往的严密关注产品与解决方案的安全性,为客户提供更满意的服务。
内容声明您购买的产品、服务或特性等应受浪潮集团商业合同和条款的约束。
本文档中描述的全部或部分产品、服务或特性可能不在您的购买或使用范围之内。
以太网业务测试方法目录一、系统适应性测试 (4)1.1、上电测试 (4)1.2、各槽位适应性测试 (5)1.3、混插测试 (5)1.4、满框测试 (6)1.5、时钟盘切换测试 (6)1.6、交叉盘切换测试 (7)1.7、SDH保护倒换测试 (8)1.8、盘保护倒换测试 (9)二、网管测试 (10)2.1、告警功能测试 (10)2.2、性能统计测试 (10)2.3、配置参数测试 (11)2.4、状态上报测试 (11)2.5、控制命令测试 (12)2.6、交叉功能测试 (12)三、功能测试 (13)3.1、最小帧长度 (13)3.2、最大帧长度 (13)3.3、异常包检测 (14)3.4、特殊包传输特性 (14)3.5、端口自适应功能 (15)3.6、自动协商功能 (15)3.7、以太网帧格式测试 (16)3.8、单播帧测试 (17)3.9 组播帧测试 (18)3.10、广播帧测试 (18)3.11、静态MAC地址配置功能 (19)3.12、MAC地址动态学习功能 (20)3.13、MAC地址老化时间测试 (20)3.14、MAC地址表容量测试 (21)3.15、MAC地址学习速度测试 (22)3.16、VLAN功能测试 (23)3.16.1、用户安全隔离测试 (23)3.16.2、VLAN Trunk功能 (23)3.16.3、设备VLAN条目数量 (24)3.16.4、VLAN支持的ID标识 (25)3.16.5、VLAN优先级测试 (25)3.16.6、PVID功能 (26)3.16.7、VMAN功能 (27)3.17、水平分割测试 (27)3.18、GFP封装测试 (29)3.18.1、GFP封装帧格式 (29)3.18.2、GFP告警检测和产生 (29)3.18.3、GFP误码监测和处理 (30)3.19、LCAS功能测试 (30)3.19.1、多径传输及最大时延差测试 (30)3.19.2、多径保护 (31)3.19.3、LCAS标准性测试 (31)3.19.4、LCAS保护时间 (32)3.19.5、时隙告警保护功能 (33)3.20、流量控制(仪表到设备) (33)3.21、流量控制(设备到仪表) (34)3.22、流量控制(拥塞形成流控) (34)3.23、端口聚合 (35)3.24、端口镜像功能 (36)3.25、生成树测试 (37)3.26、快速生成树测试 (38)3.27、基于端口优先级测试 (39)3.28、二层流功能 (39)3.29、端口接收包类型配置 (40)3.30、PING功能测试 (41)3.31、端口环回检测测试 (41)3.32、LPT功能 (42)四、指标性能测试 (43)4.1、吞吐量 (43)4.2、时延 (44)4.3、过载丢包率 (45)4.4、背靠背 (45)4.5、GE光口指标 (45)4.5.1、平均发送光功率 (46)4.5.2、接收灵敏度 (46)4.5.3、中心波长测试 (47)4.5.4、光谱宽测试 (47)4.5.5、消光比测试 (48)4.5.6、上升时间测试 (48)4.5.7、下降时间测试 (49)4.5.8、数据相关抖动测试 (49)4.5.9、发送眼图 (50)五、稳定性测试 (51)六、对通组网测试 (52)6.1、常规组网测试 (52)6.2、数据文件传送 (54)6.3、多媒体应用 (54)七、环境测试 (54)7.1、温循试验 (54)7.2、高低温性能测试 (55)7.3、电源拉偏试验 (55)7.4、单盘功耗 (56)7.5、单盘重量 (56)八、一致性测试 (56)一、系统适应性测试系统适应性测试主要针对单盘与能够使用的系统和各单盘是否进行良好的配合,单盘是否能适应各种不同的组网方式和环境变化。
IT-180ABS/IT-180ATCHigh Tg, Low CTE, Multifunctional Filled Epoxy Resin and Phenolic-Cured Laminate & PrepregIT-180A is an advanced high Tg (175℃ by DSC) multifunctional filled epoxy with low CTE, high thermal reliability and CAF resistance. It’s design for high layer PCB and can pass 260℃ Lead free assembly and sequential lamination process.Key Features =============================== Advanced High Tg Resin TechnologyIndustrial standard material with high Tg (175℃ by DSC) multifunctional filled epoxy resin and excellent thermal reliability.Lead-Free Assembly CompatibleRoHS compliant and suitable for high thermal reliability needs, and Lead free assemblies with a maximum reflow temperature of 260℃. Friendly Processing and CAF ResistanceFriendly PCB process like high Tg FR4. Users can short the learning curve when using this material.CAF ResistanceLow thermal expansion coefficient (CTE) helps to excellent thermal reliability and CAF resistance providing long-term reliability for industrial boards and automobile application.Available in Variety of ConstructionsAvailable in a various of constructions, copper weights and glass styles, including standard(HTE), RTF and VLP copper foil. ApplicationsMultilayer and High Layer PCB AutomobileBackplanesServers and Networking TelecommunicationsData StorageHeavy Copper ApplicationIndustrial ApprovalUL 94 V-0IPC-4101C Spec / 99/ 101/ 126 RoHS CompliantGlobal AvailabilityArea Address Contact e-mail TELTaiwan 22,Kung Yen 1st Rd. Ping Chen Industry Zone. Ping Chen,Taoyuan, Taiwan, R.O.C.Sales: *************.twTechnician: *****************.tw886-3-4152345 #3168886-3-4152345 #5300East China Chun Hui Rd., Xishan Economic Development Zone,Wuxi City, Jiangsu Province, ChinaSales : ****************Technician: *********************86-510-8223-5888 #516886-510-8223-5888 #3000South China168, Dongfang Road, Nanfang Industrial Park, BeiceVillage, Humen Town, Dongguan City, Guangdong Province, China Sales: ***********.cnTechnician : ***************.cn86-769-88623268 #32086-769-88623268 #550Japan No.2, Huafang Rd, Yonghe Economic Zone, Economic andTechnological Development Zone, Guangzhou,Guangdong Province, ChinaSales: ****************.cnTechnician : *****************.tw86-20-6286-8088 #8027886-3-4152345 #5388USA Tapco Circuit Supply1225 Greenbriar Drive, Suite AAddison, IL 60101, USASales: *******************************Technician : ********************************1-614-937-52051-310-699-8028Europe ITEQ Europe,Via L. Pergher, 16 38121 Trento, Italy Sales: ********************Technician : *********************39-0461-82052639-0461-820526REV 06-12ITEQ Laminate/ Prepreg : IT-180ATC / IT-180ABS IPC-4101C Spec / 99 / 101 / 126LAMINATE( IT-180ATC)Thickness<0.50 mm[0.0197 in] Thickness≧0.50 mm[0.0197 in] Units T est MethodPropertyTypical Value Spec Typical Value SpecMetric(English)IPC-TM-650(or as noted)Peel Strength, minimumA. Low profile copper foil and very low profile copperfoil - all copper weights > 17µm [0.669 mil]B. Standard profile copper foil1.After Thermal Stress2.At 125°C [257 F]3.After Process Solutions 0.88 (5.0)1.23 (7.0)1.05 (6.0)1.05 (6.0)0.70 (4.00)0.80 (4.57)0.70 (4.00)0.55 (3.14)0.88 (5.0)1.40 (8.0)1.23 (7.0)1.23 (7.0)0.70 (4.00)1.05 (6.00)0.70 (4.00)0.80 (4.57)N/mm(lb/inch)2.4.82.4.8.22.4.8.3Volume Resistivity, minimumA. C-96/35/90B. After moisture resistanceC. At elevated temperature E-24/125 3.0x1010--5.0x1010106--103--3.0x10101.0x1010--104103MΩ-cm 2.5.17.1Surface Resistivity, minimumA. C-96/35/90B. After moisture resistanceC. At elevated temperature E-24/125 3.0x1010--4.0x1010104--103--3.0x10104.0x1010--104103MΩ 2.5.17.1Moisture Absorption, maximum -- -- 0.12 0.8 % 2.6.2.1 Dielectric Breakdown, minimum -- -- 60 40 kV 2.5.6 Permittivity (Dk, 50% resin content)(Laminate & Laminated Prepreg)A. 1MHzB. 1GHzC. 2GHzD. 5GHzE. 10GHz 4.44.44.24.14.05.44.44.44.34.14.15.4 --2.5.5.92.5.5.13Loss Tangent (Df, 50% resin content) (Laminate & Laminated Prepreg)A. 1MHzB. 1GHzC. 2GHzD. 5GHzE. 10GHz 0.0150.0150.0150.0160.0170.0350.0140.0150.0150.0160.0160.035 --2.5.5.92.5.5.13Flexural Strength, minimumA. Length directionB. Cross direction ----------------500-530(72,500-76,850)410-440(59,450-63,800)415(60,190)345(50,140)N/mm2(lb/in2)2.4.4Arc Resistance, minimum 125 60 125 60 s 2.5.1 Thermal Stress 10 s at 288°C [550.4F],minimumA. UnetchedB. Etched PassPassPass VisualPass VisualPassPassPass VisualPass VisualRating 2.4.13.1Electric Strength, minimum(Laminate & Laminated Prepreg)45 30 -- -- kV/mm 2.5.6.2 Flammability,(Laminate & Laminated Prepreg)V-0 V-0 V-0 V-0 Rating UL94 Glass Transition Temperature(DSC) 175 170 minimum 175 170 minimum ˚C 2.4.25Decomposition Temperature-- -- 345 340 minimum ˚C2.4.24.6 (5% wt loss)X/Y Axis CTE (40℃ to 125℃) -- -- 10-13 -- PPM/˚C 2.4.24 Z-Axis CTEA. Alpha 1B. Alpha 2C. 50 to 260 Degrees C ------------452102.760 maximum300 maximum3.0 maximumPPM/˚CPPM/˚C%2.4.24Thermal ResistanceA. T260B. T288 -------->60>3030 minimum15 minimumMinutesMinutes2.4.24.1CAF Resistance -- -- Pass AABUS Pass/Fail 2.6.25The above data and fabrication guide provide designers and PCB shop for their reference. We believe that these information are accurate, however, the data may vary depend on the test methods and specification used. The actual sales of the product should be according to specification in the agreement between ITEQ and its customer. ITEQ reserves the right to revise its data at any time without notice and maintain the best information available to users.REV 06-12。
1200AP40 1200AP60、1203P60200D6、203D6 DAP8A 可互代203D6/1203P6 DAP8A2S0680 2S08803S0680 3S08805S0765 DP104、DP7048S0765C DP704加24V的稳压二极管ACT4060 ZA3020LV/MP1410/MP9141ACT4065 ZA3020/MP1580ACT4070 ZA3030/MP1583/MP1591MP1593/MP1430 ACT6311 LT1937ACT6906 LTC3406/AT1366/MP2104AMC2576 LM2576AMC2596 LM2596AMC3100 LTC3406/AT1366/MP2104AMC34063A AMC34063AMC7660 AJC1564AP8012 VIPer12AAP8022 VIPer22ADAP02 可用SG5841 /SG6841代换DAP02ALSZ SG6841DAP02ALSZ SG6841DAP7A、DP8A 203D6、1203P6DH321、DL321 Q100、DM0265RDM0465R DM/CM0565RDM0465R/DM0565R 用cm0565r代换(取掉4脚的稳压二极管)DP104 5S0765DP704 5S0765DP706 5S0765DP804 DP904FAN7601 LAF0001LD7552 可用SG6841代(改4脚电阻)LD7575PS 203D6改1脚100K电阻为24KOB2268CP OB2269CPOB2268CP SG6841改4脚100K电阻为20-47KOCP1451 TL1451/BA9741/SP9741/AP200OCP2150 LTC3406/AT1366/MP2104OCP2160 LTC3407OCP2576 LM2576OCP3601 MB3800OCP5001 TL5001OMC2596 LM2596/AP1501PT1301 RJ9266PT4101 AJC1648/MP3202PT4102 LT1937/AJC1896/AP1522/RJ9271/MP1540SG5841SZ SG6841DZ/SG6841DSM9621 RJ9621/AJC1642SP1937 LT1937/AJC1896/AP1522/RJ9271/MP1540STR-G5643D STR-G5653D、STR-G8653DTEA1507 TEA1533TEA1530 TEA1532对应引脚功能接入THX202H TFC719THX203H TFC718STOP246Y TOP247YVA7910 MAX1674/75 L6920 AJC1610VIPer12A VIPer22A[audio01]ICE2A165(1A/650V.31W);ICE2A265(2A/650V.52W);ICE2B0565(0.5A/650V.23W):ICE2B165(1A/650V.31W);ICE2B265(2A/650V.52W);ICE2A180(1A/800V.29W);ICE2A280(2A/800.50W).KA5H0365R, KA5M0365R, KA5L0365R, KA5M0365RN# u) t! u1 W1 B) R, PKA5L0365RN, KA5H0380R, KA5M0380R, KA5L0380R1、KA5Q1265RF/RT(大小两种体积)、KA5Q0765、FSCQ1265RT、KACQ1265RF、FSCQ0765RT、FSCQ1565Q这是一类的,这些型号的引脚功能全都一样,只是输出功率不一样。
Enhanced Low Power Half-DuplexRS-485 Transceivers SP481E / SP485EFEATURES ■5V only■Low power BiCMOS■Driver / receiver enable for multi-drop configurations■Low power shutdown mode (SP481E) ■Enhanced ESD specifications: ■±15kV Human Body Model■±15kV IEC61000-4-2 Air Discharge ■±8kV IEC61000-4-2 Contact Discharge■Available in RoHS compliant, lead free packaging.DescriptionThe SP481E and SP485E are a family of half-duplex transceivers that meet the specifications of RS-485 and RS-422 serial protocols with enhanced ESD performance. The ESD tolerance has been improved on these devices to over ±15kV for both H uman Body Model and IEC61000-4-2 Air Discharge Method. These devices are pin-to-pin compatible with MaxLinear’s SP481 and SP485 devices as well as popular industry standards. As with the original versions, the SP481E and SP485E feature Maxlinear’s BiCMOS design allowing low power operation without sacrificing performance. The SP481E and SP485E meet the requirements of the RS-485 and RS-422 protocols up to 10Mbps under load. The SP481E is equipped with a low power shutdown mode.Block DiagramOrdering Information - Back PageSP481E and SP485ERORE DE DI VCC B A GNDMarch 17, 2022Absolute Maximum RatingsThese are stress ratings only and functional operation of the device at these ratings or any other above those indicated in the operation sections of the specifications below is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability.V CC ................................................................... ............7.0V Input VoltagesLogic ........................-0.3V to (V CC + 0.5V) Drivers......................-0.3V to (V CC + 0.5V) Receivers........ ...................................±15VOutputLogic ........................-0.3V to (V CC + 0.5V) Drivers ...............................................±15V Receivers..................-0.3V to (V CC + 0.5V)Receiver output current ..................±95mA Storage Temperature .................................-65˚C to +150˚C Power Dissipation8-pin NSOIC ............................................................550mW(derate 6.60mW/°C above +70°C)Electrical CharacteristicsT AMB = T MIN to T MAX and V CC = 5V ±5% unless otherwise noted.ESD RatingsHBM - Human Body Model (A and B pins).................±15kV HBM - Human Body Model (All other pins)................. .±3kV IEC61000-4-2 Air Discharge (A and B pins)...............±15kV IEC61000-4-2 Contact Discharge (A and B pins).........±8kVT AMB = T MIN to T MAX and V CC = 5V ±5% unless otherwise noted.T AMB = T MIN to T MAX and V CC = 5V ±5% unless otherwise notedSP481E and SP485E Pinout (Top View)Pin FunctionsRO RE DE DI VCC B A GNDTest CircuitsFigure 1: RS-485 Driver DC Test Load Circuit Figure 2: Receiver Timing Test Load CircuitFigure 3: RS-485 Driver/Receiver Timing Test CircuitFigure 4: Driver Timing Test Load #2 CircuitABReceiver OutputV CCOutput Under TestSwitching Waveforms+3V0V DRIVER INPUTAB DRIVEROUTPUTV O +DIFFERENTIAL OUTPUT V A – V B 0VV O –t SKEW = |t DPLH - t DPHL |Figure 5: Driver Propagation DelaysFigure 6: Driver Enable and Disable TimesFigure 7: Receiver Propagation DelaysFigure 8: Receiver Enable and Disable TimesSwitching Waveforms (Continued)+3V 0V DE5V V OL A, B0VV OHA, BV OH V OLRV OD2+V OD2–A – B+3V 0V 5V 0VRV IL V IH RREDescriptionThe SP481E and SP485E are half-duplex differential transceivers that meet the requirements of RS-485 and RS-422. Fabricated with an Maxlinear proprietary BiCMOS process, this product requires a fraction of the power of older bipolar designs.The RS-485 standard is ideal for multi-drop applications and for long-distance interfaces. RS-485 allows up to 32 drivers and 32 receivers to be connected to a data bus, making it an ideal choice for multi-drop applications. Since the cabling can be as long as 4,000 feet, RS-485 transceivers are equipped with a wide (-7V to 12V) common mode range to accommodate ground potential differences. Because RS-485 is a differential interface, data is virtually immune to noise in the transmission line.DriversThe driver outputs of the SP481E and SP485E are differential outputs meeting the RS-485 and RS-422 standards. The typical voltage output swing with no load will be 0 Volts to 5 Volts. With worst case loading of 54Ω across the differential outputs, the drivers can maintain greater than 1.5V voltage levels. The drivers of the SP481E and SP485E have an enable control line which is active HIGH. A logic HIGH on DE (pin 3) will enable the differential driver outputs. A logic LOW on the DE (pin 3) will tri-state the driver outputs.The transmitters of the SP481E and SP485E will operate up to at least 10Mbps.ReceiversThe SP481E and SP485E receivers have differential inputs with an input sensitivity as low as ±200mV. Input impedance of the receivers is typically 15kΩ (12kΩ minimum). A wide common mode range of -7V to +12V allows for large ground potential differences between systems. The receivers of the SP481E and SP485E have a tri-state enable control pin. A logic LOW on RE (pin 2) will enable the receiver, a logic HIGH on RE (pin 2) will disable the receiver.The receiver for the SP481E and SP485E will operate up to at least 10Mbps. The receiver for each of the two devices is equipped with the fail-safe feature. Fail-safe guarantees that the receiver output will be in a H IGH state when the input is left unconnected. Shutdown ModeThe SP481E is equipped with a Shutdown mode. To enable the shutdown state, both driver and receiver must be disabled simultaneously. A logic LOW on DE (pin 3) and a Logic HIGH on RE (pin 2) will put the SP481E into Shutdown mode. In Shutdown, supply current will drop totypically 1µA.Table 1: Transmit Function Truth TableTable 2: Receive Function Truth TableMechanical DimensionsNSOIC8Drawing No:Revision: ATop ViewPOD-00000108The content of this document is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by MaxLinear, Inc. MaxLinear, Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in the informational content contained in this guide. Complying with all applicable copyright laws is the responsibility of the user. Without limiting the rights under copyright, no part of this document may be reproduced into, stored in, or introduced into a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), or for any purpose, without the express written permission of MaxLinear, Inc.MaxLinear, Inc. does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless MaxLinear, Inc. receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of MaxLinear, Inc. is adequately protected under the circumstances.MaxLinear, Inc. may have patents, patent applications, trademarks, copyrights, or other intellectual property rights covering subject matter in this document. Except as expressly provided in any written license agreement from MaxLinear, Inc., the furnishing of this document does not give you any license to these patents, trademarks, copyrights, or other intellectual property.MaxLinear, the MaxLinear logo, any MaxLinear trademarks (MxL, Full-Spectrum Capture, FSC, G.now, AirPHY, Puma, and AnyWAN), and the MaxLinear logo on the products sold are all property of MaxLinear, Inc. or one of MaxLinear’s subsidiaries in the U.S.A. and other countries. All rights reserved. Other company trademarks and product names appearing herein are the property of their respective owners.© 2022 MaxLinear, Inc. All rights reservedCorporate Headquarters: 5966 La Place Court Suite 100Carlsbad, CA 92008 Tel.:+1 (760) 692-0711 Fax: +1 (760) 444-8598 Ordering InformationNOTE: For more information about part numbers, as well as the most most up-to-date ordering information and information rating, go to /SP481E and /SP485E .Revision History。
Eaton 118701Eaton ESR5 Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling pathsEspecificaciones generalesEaton ESR5 Safety relay 1187014015081168415114.5 mm 99 mm 22.5 mm 0.218 kgUL Category Control No.: NKCR; NKCR7Certified by UL for use in Canada CSA-C22.2 No. 14-95 IEC 62061 ULCSA Class No.: 3211-83; 3211-03 UL File No.: E29184 IEC 61508, Parts 1-7 EN ISO 13849-1 EN 50178 2014/30/EU IEC/EN 60204 CE UL 508UL report applies to both US and CanadaMachines 2006/42/EGESR5-NO-41-24VAC-DCProduct NameCatalog Number EANProduct Length/Depth Product Height Product Width Product Weight CertificationsModel CodeScrew connection4 Non-delayed enable current pathsAutomatic startReinforced insulation6 kV between input circuit / NC contacts, and enable current pathsManual startSafe insulationBasic insulationFeedback circuitApproval for TÜVDetachable clampsStart inputApproval according to UL1-channelEnclosure: Polyamide (PA), not reinforcedContacts: silver tin oxide, gold plated (AgSnO2, 0.2 µ m Au)M3 screw terminals140 mA, AC65 mA, DCIP20Installation location: ≥ IP54Terminals: IP20Enclosure: IP20100 %According to EN 61000-6-4According to EN 61000-6-2Status indication of SmartWire-DT network: Green LED 10,000,000 OperationsBasic deviceRail mounting possibleTop-hat rail fixing (according to IEC/EN 60715, 35 mm) 22.5 mmIII2Normally 5.16 WElectronic safety relaysElectric connection type FeaturesFitted with:FunctionsMaterial Connection type Current consumption Degree of protection Duty factorEmitted interference Interference immunity LED indicator Lifespan, mechanical ModelMounting method Mounting width Overvoltage category Pollution degree Power lossProduct category ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)4000 V AC1000 msLevel cSIL 1, Safety integrity level, In accordance with IEC 61508 SILCL 1, Safety integrity level claim limitCat. 1, Category4.05 x 10-10, PFHd, Probability of failure per hourModule used to safely interrupt electrical circuitsMonitoring of position switchesMonitoring of emergency-stop circuitsSafety relay for monitoring emergency stop and protective door switchMax. 0.5 Hz, Input dataAC/DC As required240 Months (High Demand)167 Months (Low Demand)3 A at 3600 O/h, AC-15 at 230 V, Outputs0.4 W4 A at 360 O/h, AC-15 at 230 V, OutputsIn accordance with IEC 60947-5-1, Outputs4 A at 360 O/h, DC-13 at 24 V, Outputs2.5 A at 3600 O/h, DC-13 at 24 V, Outputs10 - 150 Hz, Amplitude: 0.15 mm, Acceleration: 2 g, (IEC/EN 60068-2-6)795 - 1080 hPa (operation)Max. 2000 m-20 °C55 °C-40 °C70 °CDry heat to IEC 60068-2-2Damp heat, constant, to IEC 60068-2-3Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 14-95Condensation: Non-condensingRated impulse withstand voltage (Uimp) Recovery timeSafety performance level (EN ISO 13849-1) Safety parameter (IEC 62061)Stop category (IEC 60204)Suitable forSwitching frequencyTypeVoltage type Mounting positionProoftestSwitching capacityVibration resistanceAir pressureAltitudeAmbient operating temperature - min Ambient operating temperature - max Ambient storage temperature - min Ambient storage temperature - max Climatic proofingEnvironmental conditionsOperating temperature - minEmergency stop category 0; emergency switching off Feedback circuitProtective door-20 °C 55 °C< 75 %2 x (0.2 – 1) mm², solid1 x (0.25 – 2.5) mm², flexible with ferrule2 x (0.25 – 1) mm², flexible with ferrule 24 - 12 AWG, solid or stranded1 x (0.2 – 2.5) mm², solid7 mm0.6 x 3.5 mm, Terminal screws2, Terminal screw, Pozidriv screwdriver 0.6 Nm, Screw terminals0.025 - 6 A1.6 W (DC operated)3.4 W (AC operated 50/60 Hz) 0 V26.4 V20.4 V24 V0 V24 V250 V24 V AC/DC (power supply) 1500 VA, max., resistive load (τ = 0 ms), at 250 V AC 42 W max., inductive load (τ = 40 ms), at 24 V DC 88 W max., resistive load (τ = 0 ms), at 220 V DC 288 W max., resistive load (τ = 0 ms), at 48 V DC 144 W max., resistive load (τ = 0 ms), at 24 V DC42 W max., inductive load (τ = 40 ms), at 220 V DC 42 W max., inductive load (τ = 40 ms), at 48 V DC 110 W max., resistive load (τ = 0 ms), at 110 V DC 42 W max., inductive load (τ = 40 ms), at 110 V DC∞ ms, Simultaneity for inputs 1/265 AOne- and two-channel4Operating temperature - maxRelative humidityTerminal capacityStripping length (main cable)Screwdriver sizeTightening torqueInrush currentPower supply circuitRated control supply voltage (Us) at AC, 50 Hz - min Rated control supply voltage (Us) at AC, 50 Hz - max Rated control supply voltage (Us) at AC, 60 Hz - min Rated control supply voltage (Us) at AC, 60 Hz - max Rated control supply voltage (Us) at DC - minRated control supply voltage (Us) at DC - max Rated insulation voltage (Ui)Rated operational voltage Breaking powerInputNominal currentNumber of inputsNumber of outputs (safety related, delayed) with contact Number of outputs (safety related, undelayed) with contact Number of outputs (signaling function, delayed) with contact230 V ACApprox. 24 V DC at input, starting and feedback circuit2.3 A, Input dataShort-circuit proof, 24 V, Fuse for control circuit supply, Control circuitMiniature circuit-breaker with characteristic C: 24 V AC/DC 6 A, For output circuits, ExternalFuse 6 A gL/gG, For output circuits, External6 A, Output fuse, Output data 122 Ω (input and starting circuits for UN)65 ms typ. (K1, K2 - for UN automatic mode) 20 ms typ.72 A² (ITH² = I1² + I2² + I3² + I4²)45 ms22 Ω (impedance)250 V6 A N/O, Limiting continuous current3 A N/C, Limiting continuous current0 W0 W0 W0 A5.16 WMeets the product standard's requirements. Meets the product standard's requirements. Meets the product standard's requirements.eaton-safety-relays-esr5-safety-relay-characteristic-curve-009.eps eaton-safety-relays-esr5-safety-relay-characteristic-curve-008.epseaton-safety-relays-relay-esr5-safety-relay-dimensions-002.eps eaton-safety-relays-relay-esr5-safety-relay-3d-drawing.eps eaton-general-esr5-safety-relay-symbol.epseaton-general-technology-esr5-safety-relay-symbol.epsDA-CE-ETN.ESR5-NO-41-24VAC-DCeaton-safety-relays-esr5-safety-relay-wiring-diagram-005.eps eaton-safety-relays-esr5-safety-relay-wiring-diagram-004.eps eaton-safety-relays-esr5-safety-relay-wiring-diagram-006.epsDA-DC-00004584.pdfDA-DC-00004576.pdfShort-circuit currentShort-circuit protection Short-circuit protection rating Number of outputs (signaling function, undelayed) with contact Permissible total cable resistancePick-up timeQuadratic summation currentReset timeResistanceSwitching voltageUninterrupted currentEquipment heat dissipation, current-dependent PvidHeat dissipation capacity PdissHeat dissipation per pole, current-dependent PvidRated operational current for specified heat dissipation (In) Static heat dissipation, non-current-dependent Pvs10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heat Characteristic curve DibujoseCAD model Esquemas eléctricosInformes de certificaciónMeets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.IL05013028ZDA-CS-esr5_no41_nz21 DA-CD-esr5_no41_nz2110.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material10.10 Temperature rise10.11 Short-circuit rating Instrucciones de montaje mCAD modelEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaIs the panel builder's responsibility. The specifications for the switchgear must be observed.Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.12 Electromagnetic compatibility10.13 Mechanical function。