YT-1200阀门定位器
- 格式:pdf
- 大小:1.22 MB
- 文档页数:24
●智能阀门定位器●电- 气阀门定位器●气 - 气阀门定位器●空气过濾减压阀●气动放大器●气锁阀●气控换向阀●电磁阀●阀位变送器●限位开关目录公司历史 3认证书4,5产品目录智能阀门定位器 6 YT-2300系列(本安型)7YT-2350系列(不锈钢型)8YT-2301L(直行程远传型)9YT-2301R(角行程远传型)10 YT-2400系列(隔爆型)11 YT-2500系列(断信号保位型)电-气阀门定位器12 YT-1300系列(电子式)直行程 13 YT-1000L角行程14 YT-1000R(标准型)15 YT-1000R(圆顶指示器)16 YT-1000R + 阀位变送器(内置型)17 YT-1000R + 阀位变送器(外置型)18 YT-1000R + 限位开关(内置型)19 YT-1000R + 限位开关(外置型)20 YT-1000R + 阀位变送器+ 限位开关(内置型)21 YT-1000R + 阀位变送器+ 限位开关(外置型)气-气阀门定位器直行程22 YT-1200L角行程23 YT-1200R 空气过濾减压阀24 YT-200, YT-205气动放大器25 YT-300,YT-305, YT-310, YT-315,YT-320气锁阀26 YT-400, YT-405气控换向阀27 YT-500,YT-505, YT-510, YT-515电磁阀28 YT-70030 PTM-6VL,R(隔爆型)31PTM-6VR + 限位开关(隔爆型)限位开关32 YT-85033 YT-860(隔爆型)支架,反馈杆 3435公司历史1996.01 成立YoungTech co.,Ltd.1996.05 生产电-气阀门定位器YT-1000L,R1996.08 生产空气过濾减压阀YT-200 ,2201997.07 生产气动放大器 YT-3001997.12 生产气-气阀门定位器YT-1200L,R1998.02 生产阀位变送器PTM-5L,R1998.08 电-气阀门定位器YT-1000L,R 获得CE证书1999.04 生产智能阀门定位器 YT-2000L,R1999.06 生产气动放大器YT-3101999.10 电-气阀门定位器YT-1000L,R 获得EM证书(韩国政府颁发)2000.01 获得ISO 9001认证2000.04 获得风险投资企业认证 (韩国政府颁发)2000.07 生产气锁阀YT-4002000.11 生产气控换向阀YT-500,5102001.01 生产阀位变送器PTM-6L, R2001.05 建新工厂2001.08 电-气阀门定位器YT-1000L,R 获得KEMA EExmdIIBT4防爆等级证书2001.11 电磁阀YT-700,710,720 获得ExdIICT6防爆等级证书2002.02 OEM生产日本本山(Motoyama)公司的EA91,EA90型电气阀门定位器2002.05 加入HART协会2002.07 获得出口有望中小型企业证书(韩国政府颁发)2002.09 生产不锈钢型空气过滤减压阀YT-2052003.02 升级为ISO 9001:20002003.10 电-气阀门定位器YT-1000L,R 获得ATEX EEx dm IIB T5防爆等级证书2003.11 生产智能阀门定位器YT-2003系列2004.01 设立研究所2004.01 生产阀位变送器PTM-5V,PTM-6V系列2005.01 电-气阀们定位器YT-1000系列获得CSA Ex md IIB T5防爆等级证书2005.01 电-气阀们定位器YT-1000L系列获得日本JIS IIB T5防爆等级证书2005.01 生产电子式阀门定位器YT-1300系列2005.08 生产不锈钢智能阀门定位器YT-1350系列和电子式阀门定位器YT-1350系列2005.09 获得韩国水利核电站供货资质。
电-气阀门定位器YT-1000系列使 用 说 明 书YTC Ver 1.02电-气阀门定位器 YT-1000系列说明书概要2安全注意事项2使用注意事项2质保期限2产品简介3标牌内容3特点4选型代码4主要参数5结构图6动作原理7外形尺寸8YT-1000L的外形尺寸图8 YT-1000R的外形尺寸图9安装10注意事项10安装时必要的工具10 YT-1000L的安装10利用支架安装YT-1000L11 YT-1000R的安装14利用支架安装YT-1000R15配管18注意事项18空压条件18配管条件18执行机构和气管的连接19电源连接-耐压防爆型 21耐压防爆型电线管的连接21耐压封闭型电缆的连接21接线端子连接22电源连接-本质安全型 22接线端子的连接22调节23零点调节23量程调节23自动/手动开关(旁路开关)24底座调节24节流孔调节25产品维护和检查25故障诊断和措施26目 录说明书概要z请充分阅读此说明书后,进行产品的安装,调试和使用。
z此说明书的内容未经事先通知的情况下可变。
z此说明书的内容未经我公司同意不得任意更改或替换。
z在此说明书未经说明的事项中出现的问题,请跟我公司或代理商联系。
z此说明书指定的参数适用于指定的型号和使用条件,有可能不能满足特殊的条件。
z为了产品的性能改进或升级,产品的参数,结构,部件等发生变动时,有可能没有反映到此说明书。
安全注意事项z为了安装人员,产品,系统的安全,安装本产品时请务必遵守本说明书注明的安全事项。
如果不正确遵守本说明书的安全事项,我公司不能保证其安全。
z因用户任意进行改造或维修本产品而发生的人身伤害或物质损失,我公司不给予赔偿。
需要维修或改造本产品时,请事先跟我公司联系。
z本产品是控制阀附件。
操作或运行时必须熟记相应控制阀的使用说明。
使用注意事项z搬运,安装或使用中,对产品过大的震动或撞击会成为产品故障的原因。
z超过规定参数范围使用也会成为产品故障的原因。
使用手册(YT-1000R/角行程) Young Tech Co., Ltd.1. 简介电-气阀门定位器YT-1000R是一种从控制器或控制系统中接受4~20mA电流信号,并向气动执行机构输送空气来控制阀门开度的装置。
2. 特征- 在5~200Hz范围内无共振现象。
- 不用更换零件只需简单操作即可进行1/2范围内的分程控制。
- 零调节和量程调节非常简单。
- 正作用和反作用,单作用和双作用之间可方便转换。
- 反馈杆连接非常简单。
- 反应速度快而准确。
- 空气消耗量小,经济性好。
- 在小型执行器也可利用先导阀的节流孔来防止振动现象。
3. 参数型号动作形式防爆等级反馈杆喷嘴连接形式环境温度选用配件1选用配件2Y T-1000RS单作用mExdmIIBT51M6×40L1小于90㎤1PTS-20℃~70℃标准指示器0无D双作用cExdmIICT52M6×63L290~180㎤2NPTH-20℃~120℃1圆顶指示器1+PTM(内置)IExiaIIBT63M8×40L3大于180㎤L-40℃~70℃2+PTM9(外置)n不防爆4M8×63L3+L/S(内置)5NAMUR4+L/S(外置)5+PTM+L/S(内置)<备注>以大气温度20℃,绝对压760㎜Hg,相对湿度65%为基准。
本产品的基本配置适用于耐压封闭防爆(ExdmⅡBT6)及容器保护等级IP66。
以单作用(Single Acting)为标准。
用量程调节旋扭可达到1/2范围内的分程控制。
标准类型以外的产品请另询问。
5. 结构图6. 动作原理为了改变阀门的位置增加输入电流。
由①力矩马达发生力,使②挡板和③喷嘴之间距离增加从而喷嘴背压急剧减小。
⑤阀芯向上移动,同时⑦气门被打开,把出口1导管空压送到⑩执行机构。
增加⑪执行机构腔内的压力而使⑫执行机构轴开始旋转。
随着⑫执行机构轴开始旋转,与反馈杆连接的反馈弹簧被拉伸。
一、 需要工具螺丝刀、活动扳手、内六角二、 具体内容电源:DC4-----20mA气源:压缩空气4kg------6kg电-气阀门定位器YTC-1000是一种从控制器或控制系统中接受4~20mA 直流直流电流信号,并向角行程气动执行机构输送空气来控制阀门位置的装置。
并且阀位变送器把当前的开启状态等比列转换成4~20mA 直流电流信号。
调节阀门的连接(配YTC---1000定位器)调节阀的反作用阀门处于反作用连接的时候,当通入定位器的电流升高时,定位器轴逆时针旋转,阀门开度增大;当通入定位器的电流降低时,阀门开度减小,,当通入定位器的电流为4mA 时,阀门应在全关位置,输入信号为20mA 时,阀门应在全开位置.具体连接方法为:气缸与定位器之间的气路连接应该为交叉接法(即两根气源管在空间上有交叉点),且反馈凸轮标有“RA ”字母的一面应向外。
连接方法见下图:100%RA●调节阀门的正作用阀门处于正作用连接的时候,当通入定位器的电流升高时,定位器轴顺时针旋转,阀门开度减小,在定位器通入20mA 电流时,阀门全关;当通入定位器的电流降低时,阀门开度增大,在电流为4 mA 时,阀门全开.具体连接方法为:气缸与定位器之间的气路连接应该为平行接法(即两根气源管在空间上无交叉点),且反馈凸轮标有“DA ”字母的一面应向外。
连接方法见下图:DA100%● 调节阀的零点调整与量程标定调节阀门的反作用输入信号4mA,调节零点,使阀门在全关位置,输入信号为20mA 时,调节量程,使阀门在接近全开的位置,输入信号为4m A 时,重新调节零点,使阀门在全关位置,输入信号为20mA 时,重新调节量程,使阀门在接近全开位置,反复几次,使4mA信号对应阀门全关,20mA信号对应全开位置。
调节阀门的正作用输入4mA信号,使阀门对应全开位置,输入信号为20mA时,调节量程,使阀门在接近全关的位置,输入信号为4 mA时,重新调节零点,使阀门在全开位置,输入信号为20mA时,重新调节量程,使阀门在接近全开位置,反复几次,使4mA对应阀门全开,20mA对应阀门全关.具体调整步骤:(以反作用接法为例)(1)零点:一般在4mA计算机显示0%时调整,逆时针调整零罗盘如上图所示,零点向关方向偏移,顺时针方向调整零点向开放向偏移。
YT-1000R定位器连接及调试方法:
一、先把连轴器连接到气动头的轴上,先不锁紧,再把定位器由支架定位在气动头气缸上。
注意调节定位器的高度,使定位器的主轴与连轴器在合适的高度位置。
观察定位器主轴与连轴器和气动头主轴在同一中心线上,然后锁紧定位器、支架与气动头的连接(连轴器先不锁紧)。
二、根据阀门是全开还是全关位置,用手转动接轴器,使上图中的扇形定位盘在相应的位置,然后把连轴器与气动头的轴锁紧。
三、按上图把气管接到气源和气动头上,注意气动头上哪个气嘴是开哪个是关。
四、接上4-20mA信号,(24VDC可以不接,也能正常工作。
如果需要位置信号反馈,可接上24VDC,中间串个电流表或电流计即可得到阀门位置反馈信号。
)4mA时,阀门是全关状态,20mA时,阀门是全开状态。
五、如果阀门未按提供的信号动作,则需调整定位器内的调节开关。
调节方法如下:
1、当信号源为4mA时,阀门未关到位,按上图“增加关”的方向调节,至合适位置即可。
2、如果信号源还未降到4mA时,阀门就已经关到位,按上图“增加开”的方向调节。
3、当信号源为20mA时,如果阀门未开到位,按上图“先松开”固定螺丝,再用螺丝刀调节旁边的调节螺丝向“增加开”的方向调节。
反之同理。
4、阀开调完后,再测试阀关的位置是否有变动,再按第1步微调。
六,阀门位置信号反馈的调节比较简单,请参考定位器说明书,按步骤即可完成。
七、调节完成后,锁好盖子。
电气阀门定位器Y T系列电气阀门定位器智能反馈模块详细调试说明 Document number【SA80SAB-SAA9SYT-SAATC-SA6UT-SA18】电气阀门定位器智能信号模块使用调试方法一、模块简介(电气)阀门定位器智能模块是新一代电气阀门定位器信号处理模块。
与电气阀门定位器配套使用,能够提高定位器的使用性能,并为远端控制系统提供精确的阀门开度信号。
模块采用新一代全数字技术研制,并采用全进口元件制作,具有精度高、抗干扰能力强、工作稳定等优点。
内部设计有LED工作状态指示,可以方便的识别模块的工作状态,并可以完全免工具进行精确调整。
一、电气连接如图所示,EP端为定位器指令输入端,用于输入4~20mA的指令信号。
PTM端接直流24V稳压电源,如串接电流表或电流传感器,可观察到电流变化。
注意事项:PTM端必须接直流稳压电源,严禁使用未经整流稳压的电源。
推荐使用直流24V开关稳压电源。
二、使模块正常工作当电气连接完成后,模块默认进入正常工作状态。
如由于运输等原因模块反馈信号偏差超出允许范围,可参照下面的“调试方法”进行调整。
三、调试方法1.电气连接分别在EP端和PTM端连接好4~20mA输入信号和24V直流稳压电源,并串接好电流表(或万用表直流100mA电流档)以便观察PTM端反馈信号电流。
注意事项:尽量不要直接连接DCS系统调试,除非能确保DCS系统是绝对完好,以便尽快完成智能模块的调试。
观察电流表读数:此时电流表读数应为4mA左右至20mA左右之间任意一个数值。
2.使模块进入调试状态按住如上图所示最右边一个按键不放,待模块上的指示灯亮起,然后放开该按键,指示灯闪烁即表示模块已进入调试状态。
观察电流表读数:此时电流表读数应为4mA,如有偏差,可按“+”或“-”键调整电流,使电流值符合要求。
3.反馈信号4mA(0%)位置调整调整EP端输入信号大小,使阀门处于需要反馈4mA信号(即0%)的位置。
使用手册(YT-1000R/角行程)Young Tech Co., Ltd.1. 简介电-气阀门定位器YT-1000R是一种从控制器或控制系统中接受4~20mA电流信号,并向气动执行机构输送空气来控制阀门开度的装置。
2. 特征- 在5~200Hz范围内无共振现象。
- 不用更换零件只需简单操作即可进行1/2范围内的分程控制。
- 零调节和量程调节非常简单。
- 正作用和反作用,单作用和双作用之间可方便转换。
- 反馈杆连接非常简单。
- 反应速度快而准确。
- 空气消耗量小,经济性好。
- 在小型执行器也可利用先导阀的节流孔来防止振动现象。
3. 参数型号动作形式防爆等级反馈杆喷嘴连接形式环境温度选用配件1选用配件2 YT-1000R单作用 ExdmIIBT5 M6×40L小于90㎤ PT -20℃~70℃标准指示器无双作用 ExdmIICT5 M6×63L 90~180㎤ NPT -20℃~120℃圆顶指示器 +PTM(内置)ExiaIIBT6 M8×40L大于180㎤ -40℃~70℃ +PTM9(外置)不防爆 M8×63L +L/S(内置)NAMUR +L/S(外置)+PTM+L/S(内置) <备注>以大气温度20℃,绝对压760㎜Hg,相对湿度65%为基准。
本产品的基本配置适用于耐压封闭防爆(ExdmⅡBT6)及容器保护等级IP66。
以单作用(Single Acting)为标准。
用量程调节旋扭可达到1/2范围内的分程控制。
标准类型以外的产品请另询问。
5. 结构图6. 动作原理为了改变阀门的位置增加输入电流。
由①力矩马达发生力,使②挡板和③喷嘴之间距离增加从而喷嘴背压急剧减小。
⑤阀芯向上移动,同时⑦气门被打开,把出口1导管空压送到⑩执行机构。
增加⑪执行机构腔内的压力而使⑫执行机构轴开始旋转。
随着⑫执行机构轴开始旋转,与反馈杆连接的反馈弹簧被拉伸。
当定位器的输入信号产生的电磁力矩与反馈弹簧的力矩相平衡时,⑫执行机构的轴停止旋转。
智能阀门定位器YT-3300,YT-3350系列使 用 说 明 书YTC V.1.05- 目 录(硬件)-说明书概要3安全注意事项和产品保证内容及保证期限3产品简介4主要特征和功能4铭牌内容和说明5型号标记方法6主要参数7内部结构8防爆认证9安装10注意事项10直行程产品外形尺寸图10角行程产品外形尺寸图11 YT-3300L的安装12 YT-3300L的安装例图 12利用支架安装YT-3300L12 YT-3300L无管路连接型的安装15 YT-3300R的安装16利用支架安装YT-3300R16气管连接17注意事项17使用的空压条件17接管的条件17执行机构和气管的连接17电源连接18注意事项18输入信号以及输出信号端子的连接18限位开关端子的连接19自动/手动开关20 PTM, HART选项模块的安装20- 目 录 (软件)-自动设定和基本操作方法22按钮说明22正常运行模式(RUN模式)的说明23自动设定 (AUTO CAL)23自动设定1 (AUTO 1) 24自动设定2 (AUTO 2)24自动设定HF (AUTO HF) 24手动模式(MANUAL)24参数模式 (PARAM)25死区(dEAdZONE)设定25 P 值设定(KP)25I 值设定(KI)25D 值设定(KD)25P_ 值设定(KP_)26 I_ 值设定(KI_)26 D_值设定(KD_)26 BIAS值设定26 KF值设定26手动设定模式 (HAND CAL)26手动设定模式的种类26阀门的零点和量程的设定26阀位反馈信号的零点和量程设定27按行程百分比降低阀门量程(PE TRIM)27设定反馈信号的正/反输出信号(TR_NORM/REV)28 HART通讯的正/反输出设定( HT NORM / REVS )28阀门模式(VALVE)28动作模式的变更 (ACT)28流量特性的变更 (CHAR)29用户自定义流量特性的设定 (USER SET)29正作用阀门紧密关闭功能的设定 (TSHUT OP)29反作用阀门紧密关闭功能的设定 (TSHUT CL)29分程控制 (SPLIT)30用户自定义零点信号设定(CST ZERO)30用户自定义量程信号设定(CST ENd)30角度补偿模式 (ITP OFF/ON)30查看模式(VIEW)31错误警告代码32主程序软件导航图33智 能 阀 门 定 位 器 YT-3300,YT-3350系列说明书概要感谢选用我公司产品。
Electro-pneumatic PositionersYT-1000L SeriesUSER'S MANUALYTC Ver 1.01Table of ContentsIntroduction3 Manufacturer Warranty3 Product Description4 Main Features and Functions4 Operation Logic4 Label Description5 Suffix Symbol5 Specification6 Parts and Assembly7 Dimension8 YT-1000L: Explosion-Proof Type8 YT-1000L: Intrinsically Safe Type8 Installation9 Safety Waring9 Tools for Installation9 YT-1000L Installation9 Piping Connection12 Supply Pressure Condition12 Pipe Condition12 Piping Connection with Actuator12 Power Connection13 Connection - Connection Port13 Connection - Cable Gland13 Connection - Power14 Connection - Ground14 Adjustment15 Adjustment - Zero15 Adjustment - Span15 Adjustment - A/M Switch (Automatic/Manual)15 Adjustment - Seat Adjuster15 Adjustment - Orifice16 Troubleshooting17IntroductionThank you for choosing YTC product. Each product is fully inspected after the production to offer you the highest quality. In order to fully utilize the product, we strongly recommend users to read this manual carefully and understood.z The manual should be provided to the end user.z The manual can be changed or revised without any prior notice. Any changes in product's specification, structure, and/or any components may not result immediate revised version of the manual.z The manual should not be duplicated or reproduced for any purpose without any approval from Young Tech Co., Ltd, South Korea.Manufacturer Warranty- For the safety, it is imperative to follow instructions in the manual. It is not manufacturer's liability for any damages which caused by users' negligences.- It is not manufacturer's liability for any damages or accidents which resulted by any alteration or modification of the product and parts. If alteration ormodification is necessary, please contact the manufacturer directly.- Manufacturer warrants the product from the date of original retail purchase of the product for one (1) year, except as otherwise stated.- Manufacturer warranty will not cover the products that the product have been subjected to abuse, accident, alteration, modification, tampering, negligence,misuse, faulty installation, lack of reasonable care, repair or service in any waythat is not contemplated in the documentation for the product, or if the modelor serial number has been altered, tampered with, defaced or removed;damages that occurs in shipment, due to act of God, failure due to powersurge, and cosmetic damage. Improper or incorrectly performed maintenance or report voids this Limited Warranty.- For detailed warranty information, please contact the corresponding local Young Tech Co., Ltd office or main office in South Korea.Product DescriptionMain Features and Functionsz It is designed for high durability and performance in high vibration environment.z Durability has proven after testing of 1 million times, at least.z Response time is very short and accurate.z Simple part change can set 1/2 Split Range.z It is economical due to less air-consumption.z Direct/Reverse action can be set easily.z Zero & Span adjustment process is simply.nozzle(③) and the flapper(②) increases, which results pressure in upper spool(⑤) exhaustion. This would cause spool(⑤) to rise upward. As the spool(⑤) rises, the air pressure will be supplied to the actuator(⑩). As the actuator's inner pressure increases, the actuator stem(⑫) will move. The movement will be transferred to cam(⑭) and pulls the span spring(⑮). The span spring(⑮)'s force will be balanced with torque motor(①), and this would cause to move flapper(②) to the normal position and reduce the gap between the nozzle(③). As the air pressure exhaustion level decreases through the nozzle(③), the pressure level in upper spool(⑤) increases again. The spool(⑤) would come back to the normal position and block the seat(⑦) which would lead to block the supply air from the actuator(⑩). When the actuator(⑩) stops the movement, the positioner would come back to the normal position. <Figure 1>Suffix SymbolYT-1000L series follows suffix symbols as follows.YT-1000L════════════════════════════════Motion Type S :LinearD :Double════════════════════════════════Explosion Proof m :Ex dm IIB T5C :Ex dm IIC T5:Ex ia IIB T6in :Non-Explosion════════════════════════════════Feedback Lever 1 :10 ~ 40mm:30∼ 70mm23 :60 ∼ 100mm4 : 100 ∼ 150mm════════════════════════════════Orifice 1 : Ø1Ø22:3 : None════════════════════════════════Connection Type 1 :PT2 :NPT════════════════════════════════Ambient Temperature S :-20 ~ 70℃H :-20 ~ 120℃L :-40 ~ 70℃════════════════════════════════* For special specification, please contact our sales department.Specification* Tested under ambient temperature of 20℃, absolute pressure of 760mmHg, and humidity of 65%.Please contact us for more detailed specification.* 1: For 1/2 Split Control, it can be applied by adjusting zero and span.*2: For inquiry regarding strokes under 10mm or above 150mm, please contact YTC.* 3: YT-1000L has different types of explosion proof certificates. Please make sure to check explosion proof grade.Parts and AssemblyInstallationSafety WarningWhen installing positioner, please ensure to read and follow safety instruction.z All input and supply pressure to valve, actuator, and other related devices must be turned off.z Use bypass valve or other equipment to avoid entire system "shut down."z Make sure there is no remaining pressure in the actuator.Tools for installation①Hexagonal wrench②Screw drivers (+) & (-)③Spanners for hexagonal-head boltsYT-1000L installationYT-1000L should be installed on linear motion valve such as globe valve or gate valve using spring return type diaphragm or piston actuator. Before installation, be sure to check for following installation components.①YT-1000L main body②Feedback lever and lever spring③Flange nut (bottom side of YT-1000L)④4 pcs. of hexagon head bolts (M8 X 1.25P)⑤4 pcs. of M8 plate washerInstallation Steps(1)Proper bracket must be made in order to attach positioner on the actuator yoke.Please consider following when making a bracket.① Feedback lever should be leveled at 50% of valve stroke. (Refer to Step 7)② Feedback lever connection bar of actuator clamp should be installed at the position that the valve stroke and numbers which indicated on the feedback lever must be fitted. (Refer to Step 8)produced in earlier step, by using bolts.<Figure 2> Please refer to backside of theavailable. Please contact YTC sales department.(3) Attach YT-1000L (with bracket) to the actuator yoke - DO NOT TIGHTENCOMPLETELY.(4) Connect YT-1000L feedback lever to the actuator clamp. The gap on theYT-1000L feedback lever is 6.5mm. The connection bar thickness should be less than(7) If connection bar does not point at 50% point, then adjust bracket or feedbacklink bar position. Failure to position at 50% would lower the linearity of the positioner. <Figure 6><Figure 6>(8) Check valve stroke. The stroke numbers are indicated on the feedback lever.Position connection bar at the number on the feedback lever according to the valve stroke. <Figure 7> To adjust, move the bracket or connection bar.Stroke 30mmStroke 70mm<Figure 7>NoteAfter instaling YT-1000L, operate the valvefrom 0% to 100% stroke by using air filterregulator on the actuator. Both of 0%and 100%, the feedback lever should nottouch the lever stopper, which is locatedon the backside of YT-1000L. <Figure 8>If the feedback lever touches the leverstopper, YT-1000L should be installedfurther away from the center of the yoke. <Figure 8>(9) After the proper installation, tighten all of the bolts on the bracket, thefeedback lever, and the connection bar.Piping ConnectionNotez To avoid entering moisture, oil, or dust into the product, please carefully make selection of supply pressure compressor.z It is recommended to attach air filter regulator before supply port of YT-1000.Supply Pressure Condition①Dry air with at least 10℃ lower than ambient temperature.②Avoid from dusty air. Filter can only sort 5 micron or larger.③Avoid any oil.④Comply with ANSI/ISA-57.3 1975(R1981)이나 ISA S7.3-1975(R1981).⑤Not to be used beyond the range of 1.4 - 7 kgf/cm2(140 - 700 kPA).⑥Set air filter regulator's supplied pressure 10% higher than actuator's spring rangepressure.Pipe Condition①Make sure inside of pipe is emptied.②Do not use pipeline that is squeezed or has hole.③To maintain flow rate, use the pipeline that has more than 6mm inner diameter.(10mm outer diameter)④Do not use extremely long pipeline system. It may affect flow rate due to thefriction inside of the pipeline.Piping connection with actuatorYT-1000 series single acting type is set to use OUT1 port. OUT1 port should be connected with supply pressure port from actuator when using single acting type of spring return actuator. For double acting type, the piping connection can be changedConnection - Power①Open terminal box cover.②Locate the poles and connect them properly. Make sure to fasten the connection.③Close back the terminal box cover. <Figure 15>Safety WarningYT-1000L designed under intrinsically safe procedures and restriction. However, intrinsically safe system can be damaged from electronic energies from other electronic devices. To avoid any system damages, please read the following.z Differentiate intrinsically safe type circuit with other types of circuit clearly.z Apply proper protection device to reduce frictions.z If possible, minimize the use of inductance and capacitance. If they must be used, set the devices at lower level than the maximum level.z Protect the wires from damages.zConnection - Ground① Open positioner's body cover.②properly. <Figure 16>AdjustmentAdjustment - Zero Point①and system must be taken account. Please refer to<Figure 17> for increase/decrease of the zero point.②When single acting actuator with spring is used, please check if the pressure levelwhich is indicated on the positioner is same to the supplied pressure level.Adjustment - Span①towards '-' direction. <Figure 18>②until both points are properly set.③Adjustment - A/M Switch (Auto/Manual)①A/M switch adjusts the valve operation toautomatic or manual.②When produced, YT-1000L is set at"A(Automatic)". If user prefers the positioner'ssetting as "M(Manual)," the setting can be<Figure 19>③If it is set as "M(Manual)", the air pressure will besupplied to the actuator directly. Always set backto "A(Automatic)" after setting change.④actuator is used, A/M Switch will not operate. <Figure 19>Adjustment - Seat Adjuster①Seat Adjuster is set according to the customer's request before the positioner isdelivered. Please do not adjust the Seat Adjuster.②Seat Adjuster is used for double acting actuator always and adjusted when theAdjustment - Orifice①If the size of actuator is too small relative to the flow rate, positioner can havehunting. In order to avoid hunting, orifice can be used. There are three types of the orifice.Actuator Size Orifice Size Suffix Symbol90 cm3less∅1190 ~ 180 cm3∅22180 cm3more none3②Remove the o-ring from OUT1 and OUT2 port and insert appropriate orifice. AfterTROUBLESHOOTING▶ Positioner does not respond to the input signal.(1)Check supply pressure level. The lever must be at least 1.4 kgf/cm2. Forspring-return type of actuator, the supply pressure level has to be larger than the spring's specification.(2)Check if input signal is properly supplied to the positioner. The signal should be4~20mA DC.(3)Check if zero point or span point is properly set.(4)Check if the positioner's nozzle has been blocked. Also, check if the pressure issupplied to the positioner and the pressure is being exhausted through the nozzle.If the nozzle has been block by any substances, please send the product forrepair.(5)Check if feedback lever has been installed properly.▶ The pressure of OUT1 reaches exhausting pressure level and does not come back down.(1)Check A/M Switch. If the switch has been damaged, replace the switch or pilotrelay valve.(2)Check for a gap or damages between the nozzle and the flapper. If damaged,please send the product to YTC for repair.▶ The pressure is exhausted only by A/M Switch.(1)Check if the positioner's nozzle has been blocked. Also, check if the pressure issupplied to the positioner and the pressure is being exhausted through the nozzle.If the nozzle has been blocked by any substances, please send the product toYTC for repair.▶ Hunting occurs.(1)Check if safety spring has been displaced. (Next to Pilot relay valve)(2)Check if the size of actuator is too small. If so, insert an orifice in order toreduce the pressure flow rate.(3)Check if there is any friction between the valve and the actuator. If so, increaseactuator's size or reduce the friction level.▶ Actuator only operates by On/Off.(1)Check actuator and positioner's acting type. Air pressure exhausts fromYT-1000L's OUT1 port as input signal level increases. Therefore, it is standard to connect to OUT1 port when single actuator is used. Make sure the spanadjustment is properly set according to the valve system.▶ Linearity is too low.(1)Check if positioner is properly positioned. Especially check if the feedback lever isparallel to the ground at 50% point.(2)Check if zero and span point have been properly adjusted. If either one of valuesis being adjusted, another one must be re-adjusted as well.(3)Check if supply air pressure level is stable from the regulator. If the level isunstable, the rgulator must be replaced.▶ Hysteresis is too low.(1)In case of double acting actuator, check if seat adjustment has been properlyperformed. Please contact YTC for any further inquiries regarding the seatadjustment.(2)Backlash can occur when the feedback lever and lever spring are loosen. Toavoid backlashing, please adjust the lever spring.(3)Check if the connection bar to the feedback lever is tightly fastened.Young Tech Co., LtdAddress:#662-8 Pungmu-Dong, Gimpo-City, Kyunggi-Do, South KoreaTelephone: +82-31-986-8545Fax: +82-31-986-2683Website: http://www.ytc.krUser Manual and other information on the documents are subjected to change without any notice. Please visit website for most updated information. Printed Date: June, 2007。
1. 简 介电-气阀门定位器YT-1000R是一种从控制器或控制系统中接受4~20mA电流信号,并向气动执行机构输送空气来控制阀门开度的装置。
2. 特 征- 在5~200Hz范围内无共振现象。
- 不用更换零件只需简单操作即可进行1/2范围内的分程控制。
- 零调节和量程调节非常简单。
- 正作用和反作用,单作用和双作用之间可方便转换。
- 反馈杆连接非常简单。
- 反应速度快而准确。
- 空气消耗量小,经济性好。
- 在小型执行器也可利用先导阀的节流孔来防止振动现象。
3. 参 数形 式 单 作 用 双 作 用输入信号 4~20mA DC阻 抗 250±15 Ohm输入压力 1.4~7kgf/㎠ (20~100Psi)行 程 0~900气源接口 PT (NPT) 1/4压力表接口 PT (NPT) 1/8电源接口 PF 1/2 (G 1/2)防爆等级 ExiaIIBT6, ExdmIIBT6, ExdmIICT6防护等级 IP 66环境温度 -20℃~70℃(标准)直 线 性 ±1% F.S ±2% F.S滞 后 度 1% F.S灵 敏 度 ±0.2% F.S ±0.5% F.S重 复 性 ±0.5% F.S空气消耗量 3LPM (Sup=1.4kgf/㎠ 20Psi)流 量 80LPM (Sup=1.4kgf/㎠ 20Psi)材 质 压 铸 鋁重 量 2.8kg4. 订 货 编 制 :YT-1000R型 号 动作形式 防爆等级 反 馈 杆 喷 嘴 连接形式 环境温度 选用配件1 选用配件2YT-1000R S 单作用 m ExdmIIBT6 1 M6×40L 1 小于90㎤1 PT S -20℃~70℃ 0 标准指示器 0 无D 双作用 c ExdmIICT6 2 M6×63L 2 90~180㎤2 NPT H -20℃~120℃ 1 圆顶指示器 1 +PTM(内置)I ExiaIIBT6 3 M8×40L 3 大于180㎤L -40℃~70℃ 2 +PTM9(外置)n 不防爆 4 M8×63L 3 +L/S(内置)5 NAMUR 4 +L/S(外置)5 +PTM+L/S(内置) <备注>z以大气温度20℃,绝对压760㎜Hg,相对湿度65%为基准。
●智能阀门定位器●电- 气阀门定位器●气 - 气阀门定位器●空气过濾减压阀●气动放大器●气锁阀●气控换向阀●电磁阀●阀位变送器●限位开关目录Young Tech Co., Ltd. Rev.C0804公司历史 3认证书4,5产品目录智能阀门定位器 6 YT-2300系列(本安型)7YT-2350系列(不锈钢型)8YT-2301L(直行程远传型)9YT-2301R(角行程远传型)10 YT-2400系列(隔爆型)11 YT-2500系列(断信号保位型)电-气阀门定位器12 YT-1300系列(电子式)直行程 13 YT-1000L角行程14 YT-1000R(标准型)15 YT-1000R(圆顶指示器)16 YT-1000R + 阀位变送器(内置型)17 YT-1000R + 阀位变送器(外置型)18 YT-1000R + 限位开关(内置型)19 YT-1000R + 限位开关(外置型)20 YT-1000R + 阀位变送器+ 限位开关(内置型)21 YT-1000R + 阀位变送器+ 限位开关(外置型)气-气阀门定位器直行程22 YT-1200L角行程23 YT-1200R空气过濾减压阀24 YT-200, YT-205气动放大器25 YT-300,YT-305, YT-310, YT-315,YT-320气锁阀26 YT-400, YT-405气控换向阀27 YT-500,YT-505, YT-510, YT-515电磁阀28 YT-700阀位变送器29 PTM-5VL,R(本安型)30 PTM-6VL,R(隔爆型)31PTM-6VR + 限位开关(隔爆型)限位开关32 YT-85033 YT-860(隔爆型)支架,反馈杆 34351996.01 成立YoungTech co.,Ltd. 1996.05 生产电-气阀门定位器YT-1000L,R 1996.08 生产空气过濾减压阀YT-200 ,220 1997.07 生产气动放大器 YT-3001997.12 生产气-气阀门定位器YT-1200L,R 1998.02 生产阀位变送器 PTM-5L,R1998.08 电-气阀门定位器YT-1000L,R 获得CE 证书 1999.04 生产智能阀门定位器 YT-2000L,R 1999.06 生产气动放大器YT-3101999.10 电-气阀门定位器YT-1000L,R 获得EM 证书(韩国政府颁发) 2000.01 获得ISO 9001认证2000.04 获得风险投资企业认证 (韩国政府颁发) 2000.07 生产气锁阀YT-4002000.11 生产气控换向阀YT-500,510 2001.01 生产阀位变送器PTM-6L, R 2001.05 建新工厂2001.08 电-气阀门定位器YT-1000L,R 获得KEMA EExmdIIBT4防爆等级证书 2001.11 电磁阀YT-700,710,720 获得ExdIICT6防爆等级证书2002.02 OEM 生产日本本山(Motoyama )公司的EA91,EA90型电气阀门定位器 2002.05 加入HART 协会2002.07 获得出口有望中小型企业证书(韩国政府颁发) 2002.09 生产不锈钢型空气过滤减压阀YT-205 2003.02 升级为ISO 9001:20002003.10 电-气阀门定位器YT-1000L,R 获得ATEX EEx dm IIB T5防爆等级证书 2003.11 生产智能阀门定位器YT-2003系列 2004.01 设立研究所2004.01 生产阀位变送器PTM-5V,PTM-6V 系列 2004.11 生产智能阀门定位器YT-2400系列2005.01 电-气阀们定位器YT-1000系列获得CSA Ex md IIB T5防爆等级证书 2005.01 电-气阀们定位器YT-1000L 系列获得日本JIS IIB T5防爆等级证书 2005.01 生产电子式阀门定位器YT-1300系列2005.08 生产不锈钢智能阀门定位器YT-1350系列和电子式阀门定位器YT-1350系列 2005.09 获得韩国水利核电站供货资质。
电气阀门定位器智能信号模块使用调试方法一、模块简介(电气)阀门定位器智能模块是新一代电气阀门定位器信号处理模块。
与电气阀门定位器配套使用,能够提高定位器的使用性能,并为远端控制系统提供精确的阀门开度信号。
模块采用新一代全数字技术研制,并采用全进口元件制作,具有精度高、抗干扰能力强、工作稳定等优点。
内部设计有LED工作状态指示,可以方便的识别模块的工作状态,并可以完全免工具进行精确调整。
一、电气连接如图所示,EP端为定位器指令输入端,用于输入4~20mA的指令信号。
PTM端接直流24V稳压电源,如串接电流表或电流传感器,可观察到电流变化。
注意事项:PTM端必须接直流稳压电源,严禁使用未经整流稳压的电源。
推荐使用直流24V开关稳压电源。
二、使模块正常工作当电气连接完成后,模块默认进入正常工作状态。
如由于运输等原因模块反馈信号偏差超出允许范围,可参照下面的“调试方法”进行调整。
三、调试方法1.电气连接分别在EP端和PTM端连接好4~20mA输入信号和24V直流稳压电源,并串接好电流表(或万用表直流100mA电流档)以便观察PTM端反馈信号电流。
注意事项:尽量不要直接连接DCS系统调试,除非能确保DCS系统是绝对完好,以便尽快完成智能模块的调试。
观察电流表读数:此时电流表读数应为4mA左右至20mA左右之间任意一个数值。
2.使模块进入调试状态按住如上图所示最右边一个按键不放,待模块上的指示灯亮起,然后放开该按键,指示灯闪烁即表示模块已进入调试状态。
观察电流表读数:此时电流表读数应为4mA,如有偏差,可按“+”或“-”键调整电流,使电流值符合要求。
3.反馈信号4mA(0%)位置调整调整EP端输入信号大小,使阀门处于需要反馈4mA信号(即0%)的位置。
按“+”或“-”键调整电流,使电流值符合要求,然后按一下上图所示最右边的按键。
观察电流表读数:如电流表读数从4mA跳至8mA左右,即表示需要反馈4mA信号(即0%)的位置已确认完毕。
智能阀门定位器YT-3400系列使 用 说 明 书YTC V.1.04- 目 录(硬件)-说明书概要3安全注意事项和产品保证内容及保证期限3危险区域使用时注意事项3产品简介4主要特征和功能4铭牌内容和说明5型号标记方法6主要参数7内部结构8安装9注意事项9 YT-3400L 外形尺寸图9 YT-3400R 外形尺寸图10排水接头的位置调整10 YT-3400L的安装11 YT-3400L的安装例图 11利用支架安装YT-3400L11 YT-3400R的安装15 YT-3400R的安装例图15利用支架安装YT-3400R15气管连接18注意事项18使用的空压条件18接管的条件19执行机构和YT-3400气管的连接19单作用执行机构和气管的连接19双作用执行机构和气管的连接19电源连接20注意事项20电流输入信号端子的连接21反馈信号端子的连接21限位开关端子的连接22接地端子的连接22自动/手动开关23流量调节旋钮的使用方法23- 目 录 (软件)-自动设定和基本操作方法24按钮说明24正常运行模式(RUN模式)的说明25自动设定 (AUTO CAL)25自动设定1 (AUTO 1) 26自动设定2 (AUTO 2)26自动设定3 (AUTO 3) 26自动设定HF(AUTO HF)26 BIAS设定26 V_0设定26手动模式(MANUAL)27参数模式 (PARAM)27参数种类27死区(dEAdZONE)设定28 P 值设定(KP)28I 值设定(KI)29D 值设定(KD)29P_ 值设定(KP_)30 I_ 值设定(KI_)30 D_ 值设定(KD_)30 HF启动(HF Off / On)30手动设定模式 (HAND CAL)31手动设定模式的种类31阀门的零点和量程的设定31阀位输出信号的零点和量程设定32按行程百分比降低阀门量程(PE TRIM)33设定反馈信号的正/反输出信号(TR_NORM/REV)33 HART通讯的正/反输出设定(HT NORM / REVS)33阀门模式(VALVE)34动作方式的变更 (ACT)34流量特性的变更 (CHAR)34用户自定义流量特性的设定 (USER SET)35正作用阀门紧密关闭功能的设定 (TSHUT OP)35反作用阀门紧密关闭功能的设定 (TSHUT CL)36分程控制 (SPLIT)36用户自定义零点信号大小设定(CTS ZERO)37用户自定义量程信号设定(CTS END)37角度补偿模式(ITP OFF / ON)37查看模式(VIEW)38错误警告代码39主程序软件导航图40智 能 阀 门 定 位 器 YT-3400系列说明书概要感谢选用我公司产品。
电气阀门定位器YT-1000系列使用说明书YT-1000系列使用说明书目录1 结构 (1)先导阀 (3)2 作用 (3)反馈部分 (4)4 反馈信号调整: (5)2作用 (7)3 动作原理 (7)安装 (9)注意事项 (9)安装时必要的工具 (9)YT-1000L的安装 (9)利用支架安装YT-1000L (9)配管 (13)注意事项 (13)使用的空压条件 (13)配管条件 (14)执行机构和气管的连接 (14)调节 (14)零点调节 (14)量程调节 (15)自动/手动开关(旁路开关) (15)底座调节 (16)节流孔调节 (17)产品维护和检查 (17)故障诊断和措施 (18)1 结构先导阀先导阀为定位器关键核心零部件,极易损坏,本公司生产的YT-1000系列先导阀可替代原装定位器先导阀。
厂家直销高仿韩国永泰YT-1000型系列电气阀门定位器此宝贝名称:先导阀,行业内称:放大器,2 作用作用是:力平衡原理通过喷嘴调节气体流量的输出大小。
先导阀是阀门定位器的主要部件之一。
先导阀就像是人的心脏一样,非常关键。
好的先导阀可以保证定位器的精确动作和使用寿命。
是电气阀门定位器的核心部件。
也是易损坏部件。
欢迎新老客户购买备件使用。
反馈部分反馈部分模块结构简图:YT-1000系列电气阀门定位器为我厂引进国外先进技术,并采用进口元件研制而成。
该系列定位器除原有阀门定位器功能外,另有阀门位置信号反馈功能、还可以带阀门开度LCD现场显示功能。
4 反馈信号调整:调整反馈信号以前,需先调整好定位器,并正确连接DC24v反馈用电源。
如需要在给定信号4mA的位置返回20mA反馈信号,可在第一步时给定定位器输入信号为20mA,然后每步调整时按20mA-16mA-12mA-8mA-4mA 依次递减定位器的输入信号。
注意:反馈信号电流在出厂时已经过整定,误差不会超过0.5mA。
2作用3 动作原理为了打开阀门增加电流信号,力矩马达(①)产生电磁场,挡板(②)受电磁场力远离喷嘴(③)。