NACV2R2K400V12.5x14TR13F中文资料
- 格式:pdf
- 大小:96.49 KB
- 文档页数:1
16®NIC COMPONENTS CORP. www www www www .SMTmagnetics.comSurface Mount Aluminum Electrolytic CapacitorsNACV SeriesFEATURES•CYLINDRICAL V-CHIP CONSTRUCTION FOR SURFACE MOUNT •HIGH VOLT AGE (160VDC AND 400VDC)•8 x10.8mm ~ 16 x17mm CASE SIZES •LONG LIFE (2000 HOURS A T +105O C)•DESIGNED FOR REFLOW SOLDERING CHARACTERISTICSDIMENSIONS (mm)CE MOUNT RoHSCompliantincludes all homogeneous materials *See Part Number System for DetailsNACV 100 M 200V 10x10.8 TR 13 FRoHS Compliant97% Sn (min.), 3% Bi (max.) 330mm (13”) Reel Tape & Reel Size in mm Working VoltageT olerance Code M=20%, K=10% Capacitance Code in µF , fi rst 2 digits are signifi cant Third digit is no. of zeros, “R” indicates decimal for values under 10mF SeriesPART NUMBER SYSTEM0.3mm max.D φL+ -IIWPABSTANDARD PRODUCTS AND CASE SIZES (mm)MAXIMUM RIPPLE CURRENT(mA rms AT 120Hz AND 105°C)MAXIMUM ESR (Ω AT 120Hz AND 20°C)Rated Voltage Range 160200250400Rated Capacitance Range 10 ~ 8210 ~ 68 3.3 ~ 47 2.2 ~ 22Operating Temperature Range-40 ~ +105°C Capacitance Tolerance ±20% (M)Max. Leakage Current After 2 Minutes0.03CV + 15µA 0.02CV + 25µAMax. Tan δ @ 120Hz0.200.200.200.25Low Temperature Stability(Impedance Ratio @ 120Hz)Z-25°C/Z+20°C 3336Z-40°C/Z+20°C66610High Temperature Load Life at 105°C2,000 hrs φD > 10mm 1,000 hrs φD = 8mm Capacitance Change Within ±25% of initial measured value Tan δLess than 200% of specifi ed value Leakage CurrentLess than the specifi ed valueCap. (µF)Working Voltage 1602002504002.2---253.3--31364.7--37386.8--444710576464572211211211211533137137150-47180180180-68215215--82235---Cap. (µF)Working Voltage 1602002504002.2---188.53.3--100.5125.74.7--70.688.26.8--48.861.01033.233.233.241.52215.115.115.118.83310.110.110.1-477.17.17.1-68 4.9 4.9--824.0---Cap. (µF)Code Working Voltage1602002504002.22R2---8x10.83.33R3--8x10.810x10.84.74R7--8x10.810x10.86.86R8--8x10.812.5x14101008x10.810x10.810x10.812.5x142222012.5x1412.5x1412.5x1416x173333012.5x1412.5x1416x17-4747016x1716x1716x17-6868016x1716x17--8282016x17---Case Size D φ±0.5L max.A±0.2B±0.2I±0.2W P±0.28x10.88.010.88.38.3 2.90.7~1.0 3.210x10.810.010.810.310.3 3.2 1.1~1.4 4.612.5x1412.514.012.812.8 4.5 1.1~1.4 4.616x1716.017.016.316.35.01.8~2.17.0PRECAUTIONSPlease review the notes on correct use, safety and precautions found on pages T10 & T11of NIC’s Electrolytic Capacitor catalog . Also found at /precautionsIf in doubt or uncertainty, please review your specifi c application - process details withNIC’s technical support personnel: tpmg@元器件交易网。
High Ohmic/High Voltage Resistors For technical questions contact: ff3dresistors@Document Number: 28732168Revision: 06-Dec-05VR25Vishay BCcomponentsFEATURES•High pulse loading capability •Small size•Lead (Pb)-free solder contacts•Pure tin plating provides compatibility with lead (Pb)-free and lead containing soldering processes•Compatible with "Restriction of the use of Hazardous Substances" (RoHS) directive 2002/95/EC (issue 2004)APPLICATIONS•Where high resistance, high stability and high reliability at high voltage are required •High humidity environment •White goods •Power suppliesA metal glazed film is deposited on a high grade ceramic body.After a helical groove has been cut in the resistive layer, tinned electrolytic copper wires are welded to the end-caps. The resistors are coated with a light blue lacquer which provideselectrical, mechanical, and climatic protection.The encapsulation is resistant to all cleaning solvents in accordance with “MIL-STD 202E, method 215” and “IEC 60068-2-45”.Note1.Ohmic values (other than resistance range) are available on request.TECHNICAL SPECIFICATIONSDESCRIPTION VALUE Resistance range 1)100k Ωto 22M ΩResistance tolerance and series:100k Ω to 15M Ω ± 1 %: E24/E96 series; ± 5 %: E24series 15M Ω to 22M Ω± 5 %: E24series; ± 10 %: E12seriesMaximum dissipation at T amb =70°C 0.25 W Thermal resistance, R th 140K/W Temperature coefficient≤ ± 200×10-6/KMaximum permissible voltage:DC 1600V RMS1150V Dielectric withstanding voltage of the insulation for 1 minute 700 V Basic specificationsIEC 60115-1B Climatic category (IEC 60068)55/155/56Stability after:load (1000hours)∆R/R max.:± 1.5 %+0.1Ωaccelerated damp heat test (6days)∆R/R max.:± 1.5 %+0.1Ωlong term damp heat test (56days)∆R/R max.:± 1.5 %+0.1ΩNoisemax.5µV/V12NC INFORMATION•The resistors have a 12-digit numeric code starting with 2322241•The subsequent:first digit for 1 % tolerance products (E24 and E96 series) or 2digits for 5 %(E24series)and 10 % (E12series)indicate the resistor type and packing.•The remaining digits indicate the resistance value:–The first 3digits for 1 % or 2digits for 5and 10 %tolerance products indicate the resistance value.–The last digit indicates the resistance decade.Last Digit of 12NC Indicating Resistance Decade12NC ExampleThe 12NC for a VR25, resistor value 7.5M Ω,5 % tolerance,supplied on a bandolier of 1000 units in ammopack, is:232224113755.RESISTANCE DECADELAST DIGIT100to 976k Ω41to 9.76M Ω5≥ 10M Ω6Document Number: 28732For technical questions contact: ff3dresistors@Revision: 06-Dec-05169VR25High Ohmic/High Voltage ResistorsVishay BCcomponents12NC - resistor type and packingTYPETOL.(%)ORDERING CODE 2322241.....BANDOLIER IN AMMOPACKBANDOLIER ON REELRADIAL TAPEDSTRAIGHT LEADS 4000 units52 mm 26 mm 52 mm 52 mm 1000 units 2000 units 5000 units 5000 units VR25± 10....8....-7.... 6....± 536...13...43...53...23...± 10-12...42...52...22...NoteProducts can be ordererd using either the 12NC or the PART NUMBER. The PART NUMBER is shown to facilitate the introduction of a unified part numbering system. Currently, this PART NUMBER is applicable in the Americas only.PART NUMBERPART NUMBER: VR25000001503JA100MODEL/SIZE SPECIAL CHARACTER TC/MATERIAL VALUE TOLERANCE PACKING 1)SPECIAL VR250000 = neutral Z = value overflow(Special)0 = standard3 digit value 1 digit multiplier Multiplier:3 = *1034 = *1045 = *105F = ± 1 %J = ± 5 %K = ± 10 %A5A2A1R5N4The 2 digits are used for all special parts.00 = standardPRODUCT DESCRIPTION: VR25 5 % A1 150KVR25 5 %A1150KMODEL/SIZETOLERANCEPACKING 1)RESISTANCE VALUEVR25± 1 %± 5 %± 10 %A1A547K = 47 K Ω50R1 = 50.1 Ω1) Please refer to table PACKING.PACKINGCODE PIECES DESCRIPTIONMODEL/SIZEA55000Bandolier in ammopack straight leads 52 mm VR25A22000Bandolier in ammopack straight leads 26 mm A11000Bandolier in ammopack straight leads 52 mm R55000Bandolier on reel straight leads 52 mm N44000Bandolier in ammopack radial taped502R V00001503J A 100 For technical questions contact: ff3dresistors@Document Number: 28732170Revision: 06-Dec-05VR25Vishay BCcomponentsHigh Ohmic/High Voltage ResistorsDIMENSIONSMARKINGThe nominal resistance and tolerance are marked on the resistor using four or five colored bands in accordance with IEC publication 60062 “Color codes for fixed resistors”.Yellow and grey are used instead of gold and silver because metal particles in the lacquer could affect high-voltage properties.OUTLINESThe length of the body (L 1) is measured by inserting the leads into holes of two identical gauge plates and moving these plates parallel to each other until the resistor body is clamped without deformation (“IEC publication 60294”).OutlineDIMENSIONS - resistor type and relevant physical dimensionsTYPE ∅ D MAX.L 1MAX.L 2MAX.∅ d VR252.56.57.50.58± 0.05MASS PER 100 UNITSTYPE MASS (g)VR25 52 mm 21.2VR25 26 mm14.8FUNCTIONAL PERFORMANCE PRODUCT CHARACTERIZATIONStandard values of nominal resistance are taken from the E96/E24/E12 series for resistors with a tolerance of ± 1 %, 5 % or 10 %. The values of the E96/E24/E12 series are in accordance with “IEC publication 60063”.Note1.The maximum voltage that may be continuously applied to the resistor element, see “IEC publication 60115-1”.The maximum permissible hot-spot temperature is 155°C.LIMITING VALUESTYPELIMITING VOLTAGE 1)(V)LIMITING POWER(W)DCRMS VR25160011500.25Document Number: 28732For technical questions contact: ff3dresistors@Revision: 06-Dec-05171VR25High Ohmic/High Voltage ResistorsVishay BCcomponentsDeratingPulse Loading CapabilityMaximum dissipation (P max ) in percentage of rated poweras a function of the ambient temperature (T amb )The power that the resistor can dissipate depends on the operating temperature.Maximum allowed peak pulse voltage in accordance with “IEC 60065 chapter 14.1”; 50discharges from a 1nF capacitor charged to ; 12discharges/minute (drift ∆R/R≤2 %)V max Application InformationHot-spot temperature rise (∆T) as a function of dissipated powerTemperature rise (∆T) at the lead end (soldering point) as a functionof dissipated power at various lead lengths after mounting For technical questions contact: ff3dresistors@Document Number: 28732172Revision: 06-Dec-05VR25Vishay BCcomponentsHigh Ohmic/High Voltage ResistorsTESTS AND REQUIREMENTSEssentially all tests are carried out in accordance with the schedule of “IEC publication 60115-1”, category LCT/UCT/56 (rated temperature range: Lower Category Temperature, Upper Category Temperature; damp heat,long term, 56days). The testing also covers the requirements specified by EIA and EIAJ.The tests are carried out in accordance with IEC publication 60068-2, “Recommended basic climatic and mechanical robustness testing procedure for electronic components” and under standard atmospheric conditions according to “IEC 60068-1”, subclause 5.3.In the Test Procedures and Requirements table the tests and requirements are listed with reference to the relevant clauses of “IEC publications 60115-1and 60068-2”; a short description of the test procedure is also given. In some instances deviations from the IEC recommendations were necessary for our method of specifying.All soldering tests are performed with mildly activated flux.TEST PROCEDURES AND REQUIREMENTSIEC 60115-1 CLAUSE IEC 60068-2 TEST METHOD TESTPROCEDUREREQUIREMENTS4.1621 (U)robustness of terminations:4.16.221 (Ua1)tensile all samples ∅ 0.6mm; load 10N;10s number of failures < 10×10-64.16.321 (Ub)bending half number of samples ∅ 0.6mm; load 5N;4×90°number of failures < 10×10-64.16.421 (Uc)torsion other half of samples 3×360° in opposite directionsno damage∆R/R max.:± 0.5 %+0.05Ω4.1720 (T a)solderability 2s; 235°Cgood tinning; no damage 4.1820 (Tb)resistance to soldering heatthermal shock: 3s; 350°C;3mm from body ∆R/R max.:± 0.5 %+0.05Ω4.1914 (Na)rapid change of temperature 30minutes at - 55°C and 30minutes at + 155°C; 5cycles ∆R/R max.:± 0.5 %+0.05Ω4.2029 (Eb)bump 3×1500 bumps in 3directions; 40g no damage∆R/R max.:± 0.5 %+0.05Ω4.226 (Fc)vibrationfrequency 10to 500Hz; displacement 1.5mm or acceleration 10g; 3directions;total 6hours (3×2hours)no damage∆R/R max.:± 0.5 %+0.05ΩDocument Number: 28732For technical questions contact: ff3dresistors@Revision: 06-Dec-05173VR25High Ohmic/High Voltage ResistorsVishay BCcomponents4.23climatic sequence:4.23.2 2 (Ba)dry heat16hours;155°C4.23.330 (Db)damp heat (accelerated) 1st cycle 24hours;55°C; 90to 100 %RH4.23.4 1 (Aa)cold2hours;- 55°C 4.23.513 (M)low air pressure2hours; 8.5kPa; 15to 35°C 4.23.630 (Db)damp heat (accelerated) remaining cycles 5days; 55°C; 95to 100 %RH R ins min.:103M Ω∆R/R max.:± 1.5 %+0.1Ω4.24.23 (Ca)damp heat (steady state)56days; 40°C; 90to 95 %RH;dissipation 0.01P n ; limiting voltage 100V (DC)∆R/R max.:± 1.5 %+0.1Ω4.25.1endurance1000hours at 70°C; P n or V max ∆R/R max.:± 1.5 %+0.1Ω4.8.4temperature coefficient between - 55°C and + 155°C(TC ×10-6/K)≤ ± 2004.7voltage proof on insulation 700V (RMS) during 1minute; V-blockmethodno breakdown 4.12noise“IEC publication 60195”max.5 µV/V 4.6.1.1insulation resistance 500V (DC) during 1minute; V-blockmethod R ins min.:104M Ω4.13short time overloadroom temperature;dissipation 6.25×P n (voltage not more than 2×limiting voltage); 10cycles;5s on and 45s off ∆R/R max.:± 2.0 %+0.05Ω4.26active flammability “Cheese-cloth test”steps of: 5/10/16/25/40 ×P n (RMS)duration 5minutesno flaming of gauze cylinderOTHER TEST IN ACCORDANCE WITH IEC 606952.2passive flammability “Needle-flame test”application of test flame for 20sno ignition of product;no ignition of under-layer;burning time less than 30sTEST PROCEDURES AND REQUIREMENTSIEC 60115-1 CLAUSE IEC 60068-2 TEST METHODTESTPROCEDUREREQUIREMENTSLegal Disclaimer NoticeVishay Document Number: Revision: 08-Apr-051NoticeSpecifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc., or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.Information contained herein is intended to provide a product description only. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Vishay for any damages resulting from such improper use or sale.。
Document Number: 28744For technical questions, contact: *************************** MCS 0402 VG01, MCT 0603 VG01, MCU 0805 VG01 andMCA 1206 VG01 thin film flat chip resistors with establishedreliability are the perfect choice for all high-reliabilityapplications typically found in military, aircraft and spacecraftelectronics. These versions supplement the families ofprofessional and precision thin film flat chip resistorsMCS 0402, MCT 0603, MCU 0805 and MCA 1206.∙Established reliability, failure rate level E6∙Advanced thin film technology ∙Pure Sn termination on Ni barrier layer ∙Single lot date code ∙Material categorization: For definitions of complianceplease see /doc?99912APPLICATIONS∙Military ∙Avionics ∙Space Notes•These resistors do not feature a limited lifetime when operated within the permissible limits. However, resistance value drift increasing over operating time may result in exceeding a limit acceptable to the specific application, thereby establishing a functional lifetime.•The failure rate level E6 (10-6/h, πQ = 0.3), corresponding to MIL Level P, is superior to level E5 (10-5/h, πQ = 1) and thus may be used as areplacement.METRIC SIZE IMPERIAL0402060308051206EN/CECC RR1005M RR1608M RR2012M RR3216M TECHNICAL SPECIFICATIONSDESCRIPTIONMCS 0402 VG01MCT 0603 VG01MCU 0805 VG01MCA 1206 VG01EN/CECC style (size)RR1005M RR1608M RR2012M RR3216MResistance range10 Ωto 1 M Ω; 0Ω 1 Ωto 1 M Ω; 0ΩResistance tolerance± 1 %; ± 0.1 %T emperature coefficient± 50ppm/K; ± 15 ppm/K Rated dissipation, P 700.063W 0.1W 0.125W 0.25W Operating voltage, U max. AC/DC50V 75 V 150V 200V Permissible film temperature, ϑF max.125︒C Operating temperature range- 55 °C to 125 °C Max. resistance change at P 70for resistance range, |∆R /R| max. after:10 Ωto 1 M Ω 1 Ωto 1 M Ω1000h≤ 0.25 %8000h≤ 0.5 %225000h≤ 1.5 %Permissible voltage against ambient(insulation):1 min; U ins75V 100V 200V 300V Continuous75V 75V 75V 75V Assessed failure rate levelE6 = 10-6/h Quality factor, πQ0.3Failure rate: FIT observed < 0.1 x 10-9/h For technical questions, contact: ***************************Document Number: 28744Notes•The products can be ordered using either the PART NUMBER or the PRODUCT DESCRIPTION.•Products within a packaging unit are single lot date code.TYPE/SIZEVERSION TCR RESISTANCE TOLERANCE PACKAGING MCS 0402MCT 0603MCU 0805MCA 1206H = EN 140401-801,“Version E”;failure rate level E6 C = ± 50 ppm/K E = ± 15 ppm/K Z = Jumper 3 digit value 1 digit multiplier MULTIPLIER8 = *10-29 = *10-10 = *1001 = *1012 = *1023 = *1034 = *1040000 = Jumper F = ± 1 %B = ± 0.1 %Z = JumperE1E0P1P5Product Description: MCT 0603-50 1% VG01 P5 287KProduct Description: MCT 0603 VG01 P5 0R0MCT 0603-50 1 %VG01P5287K MCT 0603--VG01P50R0TYPE/SIZETCR T OLERANCE VERSION PACKAGING RESISTANCE MCS 0402MCT 0603MCU 0805MCA 1206± 50 ppm/K ± 15 ppm/K ± 1 %± 0.1 %VG01 = EN 140401-801,“Version E”;failure rate level E6E1E0P1P549R9 = 49.9 Ω287K = 287 k Ω0R0 = JumperMC T 0603H Z 0000Z P 50006032873500Document Number: 28744For technical questions, contact: *************************** Note•The ordering information according to EN 140401-801:2007 shown above succeeds and replaces the ordering information according to earlier versions of the detail specification EN 140401-801 or its predecessor CECC 40401-801, for example:CECC 40401-801 EZ RR1608M C 287K F E6CECC 40401-801 S RR1608M C 287K F E6with EZ; S Assessment level, where EZ is successor to and superior replacement for SRR1608M Style, with suffix M for “metric”C Temperature coefficient, according to the detail specificationC = ± 50 ppm/K; E = ± 15 ppm/K Note•According to EN 140401-801, resistance values are to be selected from the E96 series for ±1% tolerance and from the E192 series for ±0.1 % tolerance.EN140401-801EZRR1608M-0R00-E6The elements used in the component number have the following meaning:EN140401-801EZRR1608MR287KF E6EN detail specification number Assessment level for the zero-defect approach Style (size)T emperature coefficient, according to EN 60062R = ± 50 ppm/K; P = ± 15 ppm/K Resistance, according to EN 60062, 4 characters T olerance on rated resistance, according to EN 60062F = ± 1 %; B = ± 0.1 %Failure rate level according to EN 60115-1, annex ZRTEMPERATURE COEFFICIENT AND RESISTANCE RANGEDESCRIPTIONRESISTANCE TCRTOLERANCE MCS 0402 VG01MCT 0603 VG01MCU 0805 VG01MCA 1206 VG01± 50 ppm/K± 1 %10 Ωto 1 M Ω 1 Ωto 1 M Ω1Ωto 1 M Ω1Ωto 1 M Ω± 15 ppm/K± 0.1 %100Ωto 33.2 k Ω100Ωto 47.5 k Ω100Ωto 100k Ω43.2Ωto 332k ΩJumper ≤ 20m Ω; I max. = 0.63 A ≤ 20m Ω; I max. = 1 A ≤ 20m Ω; I max. = 1.5 A≤ 20m Ω; I max. = 2 A PACKAGINGTYPECODE QUANTITY CARRIER TAPE WIDTH PITCH REEL DIAMETER MCS 0402 VG01E11000Paper tape acc. IEC 60286-3T ype I 8 mm 2 mm 180 mm/7"E010 000MCT 0603 VG01P110008 mm 4 mm P55000MCU 0805 VG01P11000P55000MCA 1206 VG01P11000P55000 For technical questions, contact: ***************************Document Number: 28744Note•Resistors MCA 1206 VG01 and MCU 0805 VG01 are marked using to the four-character code system of IEC 60062, 4.2.3.Resistors MCT 0603 VG01 and MCS 0402 VG01 do not show any marking on their light blue protective coating.Note•The given solder pad dimensions reflect the considerations for board design and assembly as outlined e.g. in standards IEC 61188-5-x, or in publication IPC 7351. They do not guarantee any supposed thermal properties, however, they will be found adequate for most general applications.DIMENSIONS AND MASSTYPEH (mm)L (mm)W (mm)W T (mm)T b (mm)T t (mm)MASS (mg)MCS 0402 VG010.32 ± 0.05 1.0 ± 0.050.5 ± 0.05> 75 % of W 0.2 ± 0.10.2 + 0.1/- 0.150.6MCT 0603 VG010.45 + 0.1/- 0.05 1.55 ± 0.050.85 ± 0.10.3 + 0.15/- 0.21.9MCU 0805 VG010.45 + 0.1/- 0.052.0 ± 0.11.25 ± 0.150.4 + 0.1/- 0.2 4.6MCA 1206 VG010.55 ± 0.1 3.2 + 0.1/- 0.2 1.6 ± 0.150.5 ± 0.259.2RECOMMENDED SOLDER PAD DIMENSIONSTYPE WAVE SOLDERINGREFLOW SOLDERING G(mm)Y (mm)X (mm)Z (mm)G (mm)Y (mm)X (mm)Z(mm)MCS 0402 VG01----0.350.550.55 1.45MCT 0603 VG010.551.10 1.102.750.650.700.95 2.05MCU 0805 VG010.801.25 1.50 3.300.900.90 1.402.70MCA 1206 VG011.40 1.50 1.90 4.40 1.50 1.15 1.753.80grade ceramic (Al2O3) substrate and conditioned to achieve the desired temperature coefficient. Specially designed inner contacts are deposited on both sides. A special laser is used to achieve the target value by smoothly cutting a meander groove in the resistive layer without damaging the ceramics. For the high ohmic range, optimized cermet products provide comparable properties. The resistor elements are covered by a protective coating designed for electrical, mechanical and climatic protection. The terminations receive a final pure tin on nickel plating.The result of the determined production is verified by an extensive testing procedure performed on 100 % of the individual resistors. This includes pulse load screening for the elimination of products with a potential risk of early life failures according to EN 140401-801, 2.1.2.2 (feasible for R≥ 10 Ω). Only accepted products are laid directly into the paper tape in accordance with EN 60286-3 (3), Type I.Products within a packaging unit are from the same production lot and carry the same date code.ASSEMBLYThe resistors are suitable for processing on automatic SMD assembly systems. They are suitable for automatic soldering using wave, reflow or vapour phase as shown in IEC61760-1 (3). Solderability is specified for 2 years after production or requalification. The permitted storage time is 20 years.The resistors are RoHS compliant; the pure tin plating provides compatibility with lead (Pb)-free soldering processes. The immunity of the plating against tin whisker growth has been proven under extensive testing.The encapsulation is resistant to all cleaning solvents commonly used in the electronics industry, including alcohols, esters and aqueous solutions. The suitability of conformal coatings, if applied, shall be qualified by appropriate means to ensure the long-term stability of the whole system.∙2000/53/EC End of Vehicle life Directive (ELV) and Annex II (ELV II)∙2011/65/EU Restriction of the use of Hazardous Substances directive (RoHS)∙2002/96/EC Waste Electrical and Electronic Equipment Directive (WEEE)APPROVALSThe resistors are approved within the IECQ-CECC Quality Assessment System for Electronic Components to the detail specification EN140401-801 which refers to EN60115-1, EN140400 and the variety of environmental test procedures of the IEC 60068 (3)series.Conformity is attested by the use of the CECC logo () as the mark of conformity on the package label.Vishay BEYS C HLAG has achieved “Approval of Manufacturer” in accordance with IEC QC001002-3, clause 2. The release certificate for “Technology Approval Schedule” in accordance with CECC240001 based on IEC QC001002-3, clause 6 is granted for the Vishay BEYSCHLAG manufacturing process.The Vishay BEYSC HLAG production facility is registered with the CAGE code D9539.RELATED PRODUCTSA wider range of TCR, tolerance and resistance values, plus the option of values from a different E series is available with products approved to EN 140401-801, Version A, without established reliability, nominal failure rate level E0 (quality factor πQ = 3). See the datasheets:∙“Professional Flat Chip Resistors”(/doc?28705)∙“Precision Flat Chip Resistors”(/doc?28700)Notes(1)Global Automotive Declarable Substance List, see .(2)CEFIC (European Chemical Industry Council), EECA (European Electronic Component Manufacturers Association), EICTA (European tradeorganisation representing the information and communications technology and consumer electronics), see /index.php?id=1053&id_article=340.(3)The quoted IEC standards are also released as EN standards with the same number and identical contents.Document Number: 28744For technical questions, contact: *************************** For technical questions, contact: ***************************Document Number: 28744Document Number: 28744For technical questions, contact: *************************** •“Precision Flat Chip Resistors”, document no. 28700EN 140400, sectional specificationEN 140401-801, detail specificationFor further information on the tests and requirements ofthese products please refer to the specifications mentionedabove, and to the following datasheets:•“Professional Flat Chip Resistors”(/doc?28705)•“Precision Flat Chip Resistors”(/doc?28700)HISTORICAL 12NC INFORMATION∙The resistors had a 12-digit code starting with 2312∙The subsequent 4 digits indicated the resistor type,specification and packaging; see the 12NC table∙The remaining 4digits indicate the resistance value:-The first 3digits indicated the resistance value-The last digit indicated the resistance decade inaccordance with the resistance decade table RESISTANCE DECADE Historical 12NC ExampleThe 12NC of a MC T 0603 VG01 resistor, value 287K andTCR 50 with ± 1 % tolerance, supplied in cardboard tape of5000units per reel was: 2312 215 02874.RESISTANCE DECADE LAST DIGIT 1Ω to 9.99Ω810Ω to 99.9Ω9100Ω to 999Ω11 k Ωto 9.99k Ω210k Ω to 99.9k Ω3100k Ω to 999k Ω41M Ω5HISTORICAL 12NC - Resistor type and packagingDESCRIPTION2312........CARDBOARD TAPE ON REEL TYPE TCRTOL.E1 1000 PIECES E0 10 000 PIECES MCS 0402 VG01± 50 ppm/K± 1 %260 0....275 0....± 15 ppm/K± 0.1 %262 0....277 0....Jumper262 90001277 90001TYPE TCRTOL.P11000 PIECES P5 5000 PIECES PW 20 000 PIECES MCT 0603 VG01± 50 ppm/K± 1 %200 0....215 0....205 0....± 15 ppm/K± 0.1 %202 0....217 0....-Jumper202 90001217 90001207 90001MCU 0805 VG01± 50 ppm/K±1 %240 0....255 0....245 0....± 15 ppm/K± 0.1 %242 0....257 0....-Jumper242 90001257 90001247 90001MCA 1206 VG01± 50 ppm/K± 1 %No 12NC assigned to MCA 1206 VG01± 15 ppm/K± 0.1 %Jumper“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product.Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein.Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.Material Category PolicyVishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant.Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards.Revision: 02-Oct-121Document Number: 91000。
1 OVERVIEW4 BEFORE OPERATING1.1 Meaning of Various LabelsThe precautions and things to note in this document involve very important information. Please read them carefully.2 SYSTEM INFORMATION3 USER INTERFACEThis unit can be used for heating/cooling.CAUTIONPlease contact the agent if you need to checkand adjust the internal components.The figure shown in this manual is forreference only and may be slightly differentfrom the actual product.This operation manual only provides information on the main functions of this system.This unit consists of electrical componentsand hot parts (danger of electric shock andscald).Before you operate this unit, make sure thatthe installation personnel have installed itproperly.This appliance is not intended for use bypersons (including children) with reducedphysical, sensory or mental capabilities, orlack of experience and knowledge, unlessthey have been given supervision orinstruction concerning use of the applianceby a person responsible for their safety.Children should be supervised to ensure thatthey do not play with the appliance.The air outlet must not be directed at anyhuman body as it is not conducive to theperson's health to be exposed to long periodsof moving cold/hot air.If the air conditioner is used together with adevice that comes with a burner, make surethe room is fully ventilated to prevent anoxia(oxygen insufficiency).Do not operate the air conditioner whenapplying fumigated insecti-cide in the room.This may cause chemicals to be depositedinside the unit, and pose a danger to thehealth of people allergic to chemicals. Thisunit should only be serviced and maintainedby a professional air conditioning serviceengineer. Incorrect servicing or maintenancecan cause electric shock, fire or leakage ofwater. Contact your dealer for servicing andmaintenance.A-weighted sound pressure of all the unitslevel are all below 70 dB. This appliance isnot intended for use by persons (includingchildren) with reduced physical, sensory ormental capabilities, or lack of experience andknowledge, unless they have been givensupervision or instruction concerning use ofthe appliance by a person responsi-ble fortheir safety.Cleaning and user maintenance shall not bemade by children without supervision.The appliance shall be installed inaccordance with national wiring regulations.This appliance is intended to domestic andused by expert or trained users in shops, inlight industry and on farms, or for commercialuse by lay persons.CAUTIONThis operation manual is suitable for air conditioning systems with standard controls. Before you start the system, please contact the agent for information on the things to note when operating the system. If the installed unit has a custom control system, please ask the agent5.2 Operating System5.2.1 About the system operations5.2.2 Cooling and heating operation of inverter central A/C5.2.3 About the heating operationThe operating program varies with different combina- tions of outdoor unit and controller.To protect this unit, please turn on the main power supply 12 hours before you start to operate this unit.If there is a power outage while the unit is running, the unit will automatically restart its operation when the power supply resumes.The indoor units of this air conditioner can be controlled separately. And the indoor units in the same system can operate in cooling and heating modes simultaneously.However, the indoor units connected to the same port of the mode selection (MS) box cannot operate in heating and cooling modes simultaneously. Under such cases:1. If the first turned on indoor unit is operated in cooling mode, indoor units turned on thereafter in the heating mode will display the “E0” (mode conflict).2. If the first turned on indoor unit is operated in heating mode, indoor units turned on thereafter in the cooling or fan mode will display the “E0” (mode conflict).Compared to the cooling operation, the heating operation takes a longer time.Need to perform the following operations to prevent the heating capacity from dropping or prevent cold air from coming out of the system.In the heating operation, as the outdoor temperature decreases, frost may be formed on the heat exchanger in the outdoor unit, making it more difficult for the heat exchanger to heat up the air. The heating capacity decreases, and a defrosting operation needs to be performed on the system in order for the system to provide sufficient heat to the indoor unit. At this point, the indoor unit will show the defrost operation on the display screen.The indoor fan motor will automatically stop running so as to prevent cold air from coming out of the indoor unit when the heating operation starts. This process will take some time. This is not a malfunction.Defrost Operation5.3 Using the Dry Program5.3.1 About the system operations5.3.2 Using the dry programThe function in this program uses the minimum temperature drop (minimum indoor cooling) to bring about a drop in humidity in the room.In the drying process, the system automatically determines the temperature and fan rotation speed (cannot use the user interface to implement the settings).5.2.4 Operating system1. Press the "switch" button on the controller.Result: The running light turns on and the system starts to run.2. Repeatedly press the mode selector on the controller to select the required operation mode.Press the "switch" button on the controller again.Result: The running light is now off, and the system stopped running.Stop1. Press the switch button on the controller.Result: The running light turns on and the system starts to run.2. Repeatedly press the mode selector on the controller.3. Press the button to adjust the air flow direction (this function is not available for all indoor units).Start4. Press the switch button on the user interface again.Result: The running light is now off, and the system stopped running.StopRefer to the user manual for the controller on how to set the required temperature, fan speed and air flow direction.AdjustDo not touch the air outlet or the horizontal blade when operating in the fan swing mode. Your fingers may be caught in the unit or the unit may be damaged.WARNINGThe refrigerant in the air conditioner is relatively safer, and usually does not leak. If the refrigerant leaks, and comes in contact with burning objects in the room, it will produce harmful gases.Shut down any flammable heating device, ventilate the room and contact the agent of the unit immediately.Do not use the air conditioner again until the maintenance personnel has confirmed that the refrigerant leakage has been sufficiently resolved.Do not attempt to modify, dismantle, remove, reinstall or repair this unit, as the improper dismantling or installation may result in electric shock or fire. Please contact the agent.If the refrigerant accidentally leaks, make sure that there is no fire around the unit. The refrigerant itself is completely safe, non-toxic and non-flammable, but it will produce toxic gases when it accidentally leaks and comes in contact with flammable substances generated by existing heaters, and burning devices in the room. You must get a qualified maintenance personnel to verify that the point of leakage has been repaired or rectified before you restore the operations of the unit.When any unusual situations arises (burning odour, etc.), stop the unit immediately and turn off the power.As a result of a certain situation, the unit has caused damage, an electric shock, or a fire. Please contact the agent.Clean the air filter and external shell of the unit. Please contact the installation or maintenance personnel to clean the air filter and external shell of the indoor unit. The installation/operation manual of the specialized indoor unit includes maintenance tips and cleaning procedures. Make sure that the clean air filter is installed in its original position.This product contains fluorinated greenhouse gases as stipulated in the Kyoto Protocol. Do not discharge the gas into the atmosphere.Refrigerant Type: R410A GWP Value: 2088Based on the applicable law, the refrigerant must be checked regularly for leakages. Please contact the installation personnel for more information.This product contains the warranty card that was completed by the agent during installation. The customer must check the completed warranty card and keep it properly.If you need to repair the air conditioner during the warranty period, please contact the agent and provide the warranty card.Complete model name of the air conditioner.Date of installation.Details on the fault symptoms or errors, and any defects.6.3 About the Refrigerant6.4 After-sales Service and Warranty6.4.1 Warranty periodAs the use of the unit for many years will eventually lead to a dust layer, the performance of the unit will degenerate to a certain extent. As professional skills are needed to dismantle and clean the unit, and for the optimal maintenance effects of this unit, please contact your agent for more details.When you request the agent for assistance, please remember to state:Temperature and humidity fluctuations are outside the normal ranges.Large power fluctuations (voltage, frequency, waveform distortion etc.) (must not use the unit if the power fluctuations exceed the allowed range). Frequent collisions and vibrations.The air may contain dust, salt, harmful gas or oil such as sulphite and hydrogen sulphide.Frequent on and off of unit or operating time is too long (in places where the air conditioning is on for 24 hours a day).In the following situations, the "maintenance cycle" and "replacement cycle" may be shortened.The unit is used in the following situations:The warranty does not cover the damage caused by dismantling or cleaning of the internal components by unauthorized agents.6.4.2 Recommended maintenance and inspection6.4.3 Shorter maintenance and replacement cycle7 TROUBLESHOOTINGThe following fault symptoms are not caused by the air conditioning:Air conditioner does not start immediately after pressing the switch button on the controller. If the operating indicator lights up, the system is working normally. In order to prevent overloading of the compressor motor, restart the air conditioner 12 minutes after the switch button is pressed to prevent it from shutting down immediately after it is on. The same start-up delay occurs after the mode selector is pressed.7.2 Fault Symptom: Non Air Conditioning Issues7.2.1 Fault symptom: System cannot runThis unit will absorb the odours of rooms, furniture, cigarettes and others, and then disperse the odours again.Small animals stray into the unit, which can also cause odors.7.2.10 Fault symptom: Strange odour from unitIn the course of operation. Control speed of fan motor to optimize the product operations.7.2.11 Fault symptom: ODU fan does not runIDifferent types of indoor units operating in the same system. When another unit is running, part of the refrigerant will still flow through this unit.7.2.12 Fault symptom: Hot air is felt when the indoor unit stopsEven if the fan speed regulation button is pressed, the fan speed does not change. During heating, when the indoor temperature reaches the set temperature, the outdoor unit will shut down, and the indoor unit switches to the quiet fan speed mode. This is to prevent cold air from blowing directly at the room user. The fan speed will not change even when another indoor unit is in heating operation, if the button is pressed.During cooling when the humidity is high. If the interior pollution of the indoor unit is severe, the indoor temperature distribution will be uneven. Need to clean the interior of the indoor unit. Ask the agent for detailed information on how to clean the unit. This operation must be carried out by qualified maintenance personnel.Surface immediately after cooling has stopped and when the indoor humidity is relatively low. This is due to the steam produced by the warm refrigerant gas on its return path to the indoor unit.The air direction is not consistent with the user interface display. The air direction does not swing. This is because the unit is controlled by the centralized controller.7.2.2 Fault symptom: Fan speed is not consistent with the setting7.2.3 Fault symptom: Fan direction is not consistent with the setting7.2.4 Fault symptom: White smoke from a certain unit (indoor unit)A "zeen" sound is heard the moment the system is powered on. This noise is produced by the electronic expansion valves inside the indoor unit as they begin to work. The sound volume will be reduced in about 1 minute.A soft and continuous "shah" sound can be heard when the system is in a cooling mode or has stopped running. This noise can be heard when the drainage pump is running (optional accessory).A loud creaking "pishi-pishi" sound can be heard once the system stops after it has heated up the room. The expansion and contraction of plastic parts caused by temperature changes will also make this noise. Once the indoor unit stops, a soft "sah" or "choro-choro" sound can be heard. This noise can be heard when another indoor unit is still running. Must maintain a small amount of refrigerant flow in order to prevent oil and refrigerant residues in the system.When the tone of the operating noise changes. This noise is caused by frequency changes.When using the unit for the first time. This is because there is dust inside the unit.7.2.6 Fault symptom: Noise from air conditioner (indoor unit)After the defrosting operation, switch the system to the heating mode. The moisture produced by the defrosting operation will become steam to be discharged out of the system.7.2.5 Fault symptom: White smoke from a certain unit (indoor unit, outdoor unit)A soft, continuous hissing sound can be heard when the system is in cooling or defrosting operation. This is the sound of the refrigerant gas flowing in the indoor and outdoor units.A hissing sound is heard the moment the system starts or stops operation or after the defrosting operation has been completed. This is the noise produced when the refrigerant flow is stopped or changed.7.2.7 Fault symptom: Noise from air conditioner (indoor unit, outdoor unit)7.2.8 Fault symptom: Noise from air conditioner (outdoor unit)7.2.9 Fault symptom: Dust and dirt in the unit8 CHANGE INSTALLATION SITE Please contact the agent to dismantle and reinstall all the units. You need specialized skills and technology to move the units.9 DISPOSALThis unit uses hydrogen fluorocarbons. Please contact the agent when you want to dispose this unit. Based on the requirements of the law, the collection, transportation and disposal of refrigerants must be in accordance with the regulations governing the collection and destruction of hydrofluorocarbons.16127000003268 V .CA版本变更为B版本封面VR改为V6R 此页不做菲林 仅作为电子文档说明封面封底:铜版纸105g内页:双胶纸100gA4规格印刷颜色为黑白。
东莞市旭枫电子科技有限公司Dongguan Xufeng Electronic Technology Co.,Ltd 客戶名稱:No. 承認書SPECIFICATION FOR APPROVAL Description:交流安規圓板陶瓷電容器CERAMIC DISC CAPACITORS SAFETY RECOGNIZEDXYCC SERIES X1:400VAC,Y1:400VACYour Part No. Your Model No. Maker Part No. Manufacturer: Approved By Date:Y1安规电容:Y1102K400V Y5P::::广东省東莞市橋頭鎮朗厦村华厦一環路22号Tel:86(769)-86290585Fax:86(769)-86290585貴公司承認欄Approval By核准Approval審核Check經辦PreparedSPECIFIC ATION SHEETCN12B102KL02NDESCRIPTION:1000PF﹢10%~-10%Y5P CLASS X1,Y1ELECRIPTICAL SPECIFICATIONCAPACITANCE:1000PF+10%~-10%AT1KHZ1.0VrmsWORKING VOLTAGE:X1:440V Y1:400V ACTEMPERATURE COEFFICIENT:Y5P1.LOWTEMPERATUREREQUIREMENT:﹣25℃2.HIGHTEMPERATURE REQUIREMENT:﹢85℃3.MAX.CAPACITANCE CHANGE OVERTEMPERATURE RANGE:﹢10%~-10%OPERATING TEMPERATURE:-25℃~﹢125℃PRODUCT SPECIFIC ATION:DIAMETER(D):9mm MAX THICKNESS(T):3.5--5.5mm MAX. LEAD SPACING(F):10.0﹢0.5/-0.5mm LEAD SIZE(d):0.6﹢0.1/-0.1mm LEAD LENGTH(L):25.0+0.5/-0.5mm LEAD STYLE:STraight DISSPATION FACTOR:2.5%MAX.INSOLUTLON RESISTANCE:10000M COATING:EPOXY TEST VOLTAGE:4KV AC FOR1MINUTES PACKING:BULKStandard No.UL/CSA Certificate No.E509457Rated VoltageF0WX2.E509457TUV CQCX1:400V AC Y1:400V ACIEC60384-14:2013CQC19001234621XYCC Safety Standard Recognized Ceramic Capacitor1.This specification is applied to following Safety Standard Recognized Ceramic Capacitor for Electronics Appliance.TUVX1,Y1Class baned on UL /CSAX1,Y1Class baned on FOWX2.E5094572.Approval Standard and Recognized No.3.Part No.Ex.CR09B221KY2NTypeBody T.C.Nominal Capacitance Lead Lead Lead RoHSDia.CapacitanceTolerance Style Spacin gLength X1:400V AC B:Y5P K:±10%L 0:10mm 2:25mm Min.H:HF Y1:400V ACE:Y5U M:±20%Y 7:7.5mm3:3.5±1mm N:RoHSF:Y5VK 5:5±1mmD4.Rating4.1Operating Temperature:25/125/214.2LeadStyle:Dongguan Xufeng Electronic Technology Co.,LtdMarking:pany Name Code :XYCC2.Type Designation :CR3.Nominal Capacitance:3-digit-system4.Capacitance Tolerance:Code5.Manufactured Date:AbbreviationEx.2019Ex.1(January)912(February)92::10(October)9O 11(November)9N 12(December)9DC:Made in DONG GUAN6.Approval Mark:TUV Approval Mark:UL Approval Mark:CQC Approval Mark:(On the Label)EN/UL F0WX2.E509457:X1,Y1Rated Voltage Mark:400V ~,400V ~XYCC Safety Standard Recognized Ceramic Capacitor :Performance“room condition”temperature :20~35℃,humidity:45~75%,atmospheric pressure 86~106kPa.No.Item SpecificationTest Condition1Dielectric StrengthBetween lead wiresNo failureThe capacitors shall not be damage when AC2600V(for Y2Class)and AC4000V (for Y1Class)are applied between the lead wires for 60sec.(charge/discharge current <50mA)Body insulationNo failureFirst the terminals of the capacitor shall be connected together.Then a metal foil shall be closely wrapped around the body of the capacitor distance of about 3to 4mm from each terminal.Then the capacitor shall be inserted into a container filled with metal balls of about 1mm diameter.Finally AC2600V is applied for 60sec.between the capacitor lead wires and metal balls.(charge/discharge current ≦50mA)2Insulation Resistance (I.R.)10000M ΩminThe insulation resistance shall be measured with500±50VDC with 60±5sec of charging.3CapacitanceWithin specified tolerance.Char Frequency Voltage NPO/SL 1MHz ±20%5.0Vrms MaxY5P/Y5U/Y5V 1KHz ±20%The measurement at reference temperature 25∘C 4Dissipation Factor(D.F.)Char.Specified The Capacitance shall be measured At 25℃with 1±0.1KHZ for X7R&Y5P,with 1±0.1MHZ for COG and 5Vrms max.NPO/SL Q ≧300Y5PD.F ≦2.5%Y5U/Y5V D.F ≦5.0%5Temperature CharacteristicChar.Cap.Change The Capacitance measurement shall be made at each stepspecified in Table.Pre-treatment:Capacitor shall be stored at max.temperature for 1hour.Then placed at room condition for (※)24±2hours before measurements.NPO Within ±60ppm SL +350~1000%Y5P Within ±10%Y5U -56%/+22%Y5V -82%/+22%6Robustness ofTerminationTensileLead wire shall not cut off Capacitor shall not be broken.With the termination in its normal position the specimen is held by its body in such a manner that the axis of the termination isvertical the tensile force of 10N shall be applied to thetermination in the direction of its axis and acting in a direction away from the body of the specimen.Bending Lead wire shall not cut off Capacitor shall not be broken.With the termination in its normal position the specimen is held by its body in such a manner that the axis of the termination isvertical :a mass applying a force of 5N is then suspended from the end of the termination.The body of the specimen is then inclined within a period of 2to 3sec.,through an angle of a approximately 90in the vertical plane and then returned to its initial position over the same period of time;this operation constitutes one bend.One bend immediately followed by a second bend in the opposite direction.StepTemperature P.F1+25±2℃2Min.operation temp.3+25±2℃4Max.operation temp.5+25±2℃1sec)by UL1414and CSA E384-14previous safety standards.(UL1414is deleted in this SPEC11Flame Test The capacitor flame discontinue asfollows.The capacitor shall be subjected to applied for 15sec.And thenremoved for 15sec,until 5cycle.(Unit:mm)12Active FlammabilityThe cheese-cloth shall not be on fireThe specimens shall be individually wrapped in at least one but more than two complete layers of cheese-cloth The specimens shall be subjected to 20discharges.The interval betweensuccessive discharges shall be 5sec.The Uac shall be maintained for 2min.after the last discharge.C1,2:1μF ±10%C3:0.33μF ±5%10KV Ct :3μF ±5%10KV Cx :CapacitorL1-10:1.5mH ±20%16A Rod core choke R :100Ω±2%,Uac :Ur ±5%Ur :Rated working voltage F :Fuse,Rated 10AUt :Voltage applied to CtCycleTime1to 430sec.max.560sec.Max.。
RER70I08D-5RFB - RER70JE-6327 - RER70K2 - RER70LT1 - RER70M1GO24L253B - RER70N06 - RER70N1002 - RER70R100R -RER70R301 - RER70R301M - RER70S2R49R - RER710 - RER7100110 - RER71001-10 - RER7100113 - RER71001-13 - RER7100116 -RER71001219 - RER71001-219 - RER71001231 - RER71001-231 - RER71001249 - RER7100125 - RER71001-25 - RER71001255 -RER71001-255 - RER71001255ERICSSON - RER71001-255ERICSSON - RER7100137 - RER71001-37 - RER7100155 - RER71001-55 - RER7100167 - RER71001-67 - RER710037 - RER7101SYCBE - RER71901-42 - RER74F1001R - RER74F48R30W - RER74F48R7R - RER75 - RER7511R8 - RER7511R8R - RER7515251 - RER751525-1 - RER75152547 - RER751525-47 - RER751OROM - RER7524R90 - RER75262525 - RER752625-25 - RER75262525C - RER752625-25C - RER753010R - RER7534R0R - RER753R40R - RER754R02R - RER75514421 -RER7551442-1 - RER755144222 - RER7551442-22 - RER75514422L - RER7551442-2L - RER755144233 - RER7551442-33 - RER755144247 - RER7551442-47 - RER755144312 - RER7551443-12 - RER755144322 - RER7551443-22 - RER75514441 - RER7551444-1 - RER755144433 - RER7551444-33 - RER755144447 - RER75514451 - RER7551445-1 - RER755144556 - RER7551445-56 - RER755144582 - RER756980M - RER75E6811R30M - RER75E-X - RER75F01R0R - RER75F0R75 - RER75F0R75R - RER75F100 - RER75F1001 - RER75F1001M -RER75F1001P - RER75F1001R - RER75F1001RC02 - RER75F1002 - RER75F1002M - RER75F1002R - RER75F102 - RER75F102R -RER75F1050 - RER70GR500IC供应:BIOS06716E、10NF121050V10、SMD59C11SNSO-26、RS-1-216R8、SR212C682MAT、BIOS067-16E、10NF-1210-50V-10、SMD59Kohm-1 116W、RS1217、SR212C821KAA、BIOS067177-08、10NF-1210-50V-10 、SMD5A-125V、RS-12-17、SR212C822KAA、BIOS-0677、10NF-1210-50V-5 -、SMD5C100835、RS12178、SR212C822KAATR、BIOS-067-77-08、10NF121050V5C0G、SMD5C1008-35、RS-1-2-178、SR212C822KAT。
各种贴片电容容值表X7R贴片电容简述X7R贴片电容属于EIA规定的Class 2类材料的电容。
它的容量相对稳定。
X7R贴片电容特性具有较高的电容量稳定性,在-55℃~125℃工作温度范围内,温度特性为±15%。
层叠独石结构,具有高可靠性。
优良的焊接性和和耐焊性,适用于回流炉和波峰焊。
应用于隔直、耦合、旁路、鉴频等电路中。
X7R贴片电容容量范围厚度与符号对应表符号A C E G J K M N P Q X Y Z最大厚度毫米(英寸)0201~1206 X7R贴片电容选型表封装尺020040060080120125112*********工作电2011125102050100A150A220330AJJJKJCGGJJ470ACGGJJJJJJK680电容(pFGGJJJJJJC1000AK1500CGGJJJJJJJJJJJJM2200GGJJJJJCCJJJJJJ3300JMCGJJJJJJJ4700JJJJJMJ JG J J J J CC P6800 J J J J J JJ J J J J J J G J J J CJ J PC G G J J J J J J J J J J J MC G MJ JJJJ J J J JJ MJ G M 电容量 J J J J J J J J MG G (uF)J J J J M J J J J J MJJJ J J G JJ J PJG G GJ J J J J J J J MJ J J J J J J GG J J M J J J JJ J M M M MN M M M MN M MQ M N MPQ1625501016255010010162550工作电压 1610020010162550100200500 0603080512060201封装尺寸04021210~2225 X7R贴片电容选型表封装尺121181182222222 1125102050510205051051020工作电510 10001500JJJJJJM2200电容(pF3300JJJJJJM4700JJJJJJM6800JJJJJJMKKKKMMXXXXMPJJJJJJPKKKPMMXXXXMPJJJJJJKKKXMMXXXXMPJJJJJJKKKZMMXXXXMPJJJJJMKKKMMXXXXMPJJJJMKKPMMXXXXMP电容(uFMJJZMKMPXXXMJJMMMMZKPMMXXXMPZMMMXZPNNXPNNMMXQZ1010162550工作电压 100200500501002005005010050100200501002225 封装尺寸1825181212102220NPO COG 贴片电容容量规格表默认分类 2009-07-15 16:28 阅读354 评论1字号:大大中中小小NPO贴片电容简述NPO(COG)贴片电容属于Class 1温度补偿型电容。
VRF产品参数表标准2015版型号RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) RFUT(D) 18MX 22MX 25MX 28MX 32MX 36MX 40MX 45MX 50MX 56MX 63MX 71MX 80MX 90MX 100MX 112MX 125MX 140MX电源(Ph/V/Hz)单相,220V,50Hz名义制冷能力(kW)※1 1.8 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6 6.3 7.1 8 9 10 11.2 12.5 14 制冷制冷输入功率(W)57 57 57 57 57 57 89 89 120 120 120 120 120 138×2138×2138×2138×2138×2制冷运行电流(A)0.26 0.26 0.26 0.26 0.26 0.26 0.4 0.4 0.55 0.55 0.55 0.55 0.55 1.25 1.25 1.25 1.25 1.25 名义制热能力(kW)※2 2.3 2.5 2.8 3.2 3.6 4 4.5 5 5.6 6.3 7.1 8 9 10 11 12.5 15 16 制热制热输入功率(W)57 57 57 57 57 57 89 89 120 120 120 120 120 138×2138×2138×2138×2138×2制热运行电流(A)0.26 0.26 0.260.26 0.26 0.26 0.4 0.4 0.55 0.55 0.55 0.55 0.55 1.25 1.25 1.25 1.251.25 辅助电电热能力(kW) 1 1 1 1 1 1 1.8 1.8 1.8 1.8 1.8 1.8 1.8 3.6 3.6 3.6 3.6 3.6 加热辅电电流(A) 4.6 4.6 4.6 4.6 4.6 4.6 8.2 8.2 8.2 8.2 8.2 8.2 8.2 16.4 16.4 16.4 16.4 16.4 低温制热能力(kW)※3 1.6 22.2 2.5 2.83.2 3.6 44.5 55.66.37.1 8 9 10 11.2 12.5 风扇类别及数量离心×1离心×1离心×1离心×1离心×1离心×1离心×2离心×2离心×2离心×2离心×2离心×2离心×2离心×4离心×4离心×4离心×4离心×4电机输出功率(kw)0.018 0.018 0.018 0.018 0.018 0.014 0.032 0.032 0.035 0.035 0.035 0.035 0.035 0.065×20.065×20.065×20.065×20.065×2风机特标准风量(m3/ h) 400 400 400 400 500 500 850 850 1250 1250 1250 1250 1250 1800 1800 1800 1800 1800 性标准静压(Pa)0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 最大静压(Pa)20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20室内机外形尺寸:长×宽610×500×2201105×500×2201656×520×220×高(mm)室内机装箱尺寸:长×宽707×548×2801174×549×2941696×523×255×高(mm)尺寸面板外形尺寸:长×宽×------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 高(mm)面板装箱尺寸:长×宽×------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 高(mm)15/17 15/17 15/17 15/17 16/18 16/18室内机净重/毛重(kg)((((((25/27 25/27 28/30 28/30 28/30 28/30 28/30 38/40 40/42 40/42 40/42 40/42重量15.5/17 15.5/17 15.5/17 15.5/17 16.5/18 16.5/18 (26/28) (26/28) (29/31) (29/31) (29/31) (29/31) (29/31) (40/42) (42/44) (42/44) (42/44) (42/44) .5).5).5).5).5).5)面板净重/毛重(kg)------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 节流方式电子膨胀阀线控器YR-E14/YR-E17/YR-E16/YR-E160控制器是否标配否遥控器YR-H005遥控器总成是否标配否气管(mm) φ9.52 φ9.52 φ9.52 φ9.52 φ12.7 φ12.7 φ12.7 φ12.7 φ12.7 φ12.7 φ15.88 φ15.88 φ15.88 φ15.88 φ19.05 φ19.05 φ19.05 φ19.05配管尺液管(mm) φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35φ6.35 φ6.35 φ6.35 φ9.52 φ9.52 φ9.52 φ9.52 φ9.52 φ9.52 φ9.52 φ9.52 寸水管(mm) φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24 φ24冷媒配管连接方式喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口噪音声压级(dB(A))35/32/ 35/32/ 35/32/ 35/32/ 35/32/ 35/32/ 35/32/ 35/32/ 39/37/ 39/37/ 39/37/ 39/37/ 39/37/ 47/45/ 47/45/ 47/45/ 47/45/ 47/45/ 30 30 30 30 30 30 30 30 35 35 35 35 35 43 43 43 43 43※4声功率级(dB(A))------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------※1 室内温度:27℃DB,19℃WB/室外温度:35℃DB,24℃WB /等效管长:7.5m,高低差:0m ※2室内温度:20℃DB,14.5℃WB/室外温度:7℃DB,6℃WB /等效管长:7.5m,高低差:0m ※3 室内温度:20℃DB,14.5℃WB/室外温度:2℃DB,1℃WB /等效管长:7.5m,高低差:0m ※4 本噪音值是在半消音室内测得的,因受周围噪音及反射声的影响,一般要高于本噪音值编制人:型号RFTS(D)18MX RFTS(D)22MX RFTS(D)25MX RFTS(D)28MX RFTS(D)32MX RFTS(D)36MX RFTS(D)40MX RFTS(D)45MX RFTS(D)50MX RFTS(D)56MX RFTS(D)63MX RFTS(D)71MX 电源(Ph/V/Hz)单相,220V,50Hz名义制冷能力(kW)※1 1.8 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6 6.3 7.1制冷制冷输入功率(W)50 50 50 50 56 56 65 65 80 80 117117 制冷运行电流(A)0.23 0.23 0.23 0.23 0.26 0.26 0.3 0.3 0.37 0.37 0.54 0.54 名义制热能力(kW)※2 2.3 2.5 2.8 3.2 3.6 4 4.5 5 5.6 6.3 7.1 8制热制热输入功率(W)50 50 50 50 56 56 65 65 80 80 117 117 制热运行电流(A)0.23 0.23 0.23 0.23 0.26 0.26 0.3 0.3 0.37 0.37 0.54 0.54辅助电电热能力(kW) 1 1 1 1 1 1 1 1 1.8 1.8 1.8 1.8加热辅电电流(A) 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 8.2 8.2 8.2 8.2 低温制热能力(kW)※3 1.6 2 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6 6.3 风扇类别及数量离心×2离心×2离心×2离心×2离心×2离心×2离心×2离心×2离心×3离心×3离心×3离心×3电机输出功率(kw)0.014 0.014 0.014 0.014 0.023 0.023 0.051 0.051 0.044 0.044 0.055 0.055风机特标准风量(m3/ h) 480 480 480 480 550 550 600 600 800 800 930 930性标准静压(Pa)0 0 0 0 0 0 0 0 0 0 0 0 最大静压(Pa)30 30 30 30 30 30 30 30 30 30 30 30室内机外形尺寸:长×宽850×420×1851170×420×185×高(mm)室内机装箱尺寸:长×宽1045×540×2701365×540×270×高(mm)尺寸面板外形尺寸:长×宽×------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 高(mm)面板装箱尺寸:长×宽×------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 高(mm)室内机净重/毛重(kg)16.5/21.5 16.5/21.5 16.5/21.516.5/21.5 17.5/22.5 17.5/22.5 18.5/23.5 18.5/23.5 22.2/28.5 22.2/28.5 24/30 24/30重量(17.5/22.5) (17.5/22.5) (17.5/22.5) (17.5/22.5) (18.5/23.5) (18.5/23.5) (19.5/24.5) (19.5/24.5) (23.7/30) (23.7/30) (25.5/31.5) (25.5/31.5) 面板净重/毛重(kg)------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 节流方式电子膨胀阀线控器YR-E14/YR-E17/YR-E16/YR-E160控制器是否标配否遥控器YR-H005遥控器总成是否标配否气管(mm) φ9.52 φ9.52 φ9.52 φ9.52 φ12.7 φ12.7 φ12.7 φ12.7 φ12.7 φ12.7 φ15.88 φ15.88配管尺液管(mm) φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ9.52 φ9.52 寸水管(mm) φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25冷媒配管连接方式喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口噪音声压级(dB(A))27/24/21 27/24/21 27/24/21 27/24/21 30/28/25 30/28/25 33/30/37 33/30/37 33/30/28 33/30/28 36/33/31 36/33/31 ※4声功率级(dB(A))------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------※1 室内温度:27℃DB,19℃WB/室外温度:35℃DB,24℃WB /等效管长:7.5m,高低差:0m ※2室内温度:20℃DB,14.5℃WB/室外温度:7℃DB,6℃WB /等效管长:7.5m,高低差:0m ※3 室内温度:20℃DB,14.5℃WB/室外温度:2℃DB,1℃WB /等效管长:7.5m,高低差:0m ※4 本噪音值是在半消音室内测得的,因受周围噪音及反射声的影响,一般要高于本噪音值编制人:型号RFTSA(D) RFTSA(D) RFTSA(D) RFTSA(D) RFTSA(D) RFTSA(D) RFTSA(D) RFTSA(D) RFTSA(D) RFTSA(D) RFTSA(D) RFTSA(D) 18MX 22MX 25MX 28MX 32MX 36MX 40MX 45MX 50MX 56MX 63MX 71MX电源(Ph/V/Hz)单相,220V,50Hz名义制冷能力(kW)※1 1.8 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6 6.3 7.1 制冷制冷输入功率(W)50 50 50 50 56 56 65 65 80 80 117 117 制冷运行电流(A)0.23 0.23 0.23 0.23 0.26 0.26 0.3 0.3 0.37 0.37 0.54 0.54 名义制热能力(kW)※2 2.3 2.5 2.8 3.2 3.6 4 4.5 5 5.6 6.3 7.1 8制热制热输入功率(W)50 50 50 50 56 56 65 65 80 80 117 117 制热运行电流(A)0.23 0.23 0.23 0.23 0.26 0.26 0.3 0.3 0.37 0.37 0.54 0.54辅助电电热能力(kW) 1 1 1 1 1 1 1 1 1.8 1.8 1.8 1.8 加热辅电电流(A) 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 8.2 8.2 8.2 8.2 低温制热能力(kW)※3 1.6 2 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6 6.3 风扇类别及数量离心×2离心×2离心×2离心×2离心×2离心×2离心×2离心×2离心×3离心×3离心×3离心×3电机输出功率(kw)0.014 0.014 0.014 0.014 0.023 0.023 0.051 0.051 0.044 0.044 0.055 0.055 风机特标准风量(m3/ h) 480 480 480 480 550 550 600 600 800 800 930 930 性标准静压(Pa)0 0 0 0 0 0 0 0 0 0 0 0 最大静压(Pa)30 30 30 30 30 30 30 30 30 30 30 30室内机外形尺寸:长×宽850×420×1851170×420×185×高(mm)室内机装箱尺寸:长×宽1045×540×2701365×540×270×高(mm)尺寸面板外形尺寸:长×宽×------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 高(mm)面板装箱尺寸:长×宽×------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 高(mm)室内机净重/毛重(kg)15.7/20.7 15.7/20.7 15.7/20.7 15.7/20.7 16.7/21.7 16.7/21.7 17.7/22.7 17.7/22.7 21.4/27.4 21.4/27.4 23.2/29.2 23.2/29.2重量(16.7/21.7) (16.7/21.7) (16.7/21.7) (16.7/21.7) (17.7/22.7) (17.7/22.7) (18.7/23.7) (18.7/23.7) (22.9/28.9) (22.9/28.9) (24.7/30.7) (24.7/30.7) 面板净重/毛重(kg)------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ 节流方式电子膨胀阀线控器YR-E14/YR-E17/YR-E16/YR-E160控制器是否标配否遥控器YR-H005遥控器总成是否标配否气管(mm) φ9.52 φ9.52 φ9.52 φ9.52 φ12.7 φ12.7 φ12.7 φ12.7 φ12.7 φ12.7 φ15.88 φ15.88配管尺液管(mm) φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ6.35 φ9.52 φ9.52 寸水管(mm) φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25 φ25冷媒配管连接方式喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口噪音声压级(dB(A))27/24/21 27/24/21 27/24/21 27/24/21 30/28/25 30/28/25 33/30/37 33/30/37 33/30/28 33/30/28 36/33/31 36/33/31 ※4声功率级(dB(A))------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------※1 室内温度:27℃DB,19℃WB/室外温度:35℃DB,24℃WB /等效管长:7.5m,高低差:0m ※2室内温度:20℃DB,14.5℃WB/室外温度:7℃DB,6℃WB /等效管长:7.5m,高低差:0m ※3 室内温度:20℃DB,14.5℃WB/室外温度:2℃DB,1℃WB /等效管长:7.5m,高低差:0m ※4 本噪音值是在半消音室内测得的,因受周围噪音及反射声的影响,一般要高于本噪音值编制人:相当马力2 2.53 3.2 3.64 4.5 5 5.3型号RFUM(D)56MX RFUM(D)71MX RFUM(D)80MX RFUM(D)90MX RFUM(D)100MX RFUM(D)112MX RFUM(D)125MX RFUM(D)140MX RFUM(D)150MX电源(Ph/V/Hz )单相,220V ,50Hz名义制冷能力(kW )※1 5.6 7.1 8 9 10 11.2 12.5 14 15 制冷制冷输入功率(W ) 235 235 235 280 280 280 280 280 280 制冷运行电流(A ) 1.1 1.1 1.1 1.4 1.4 1.4 1.4 1.4 1.4 名义制热能力(kW )※2 6.3 8 9 10 11.2 12.5 15 16 17制热制热输入功率(W ) 235 235 235 280 280 280 280 280 280制热运行电流(A ) 1.1 1.1 1.1 1.4 1.4 1.4 1.4 1.4 1.4辅助电电热能力(kW ) 1.8 1.8 1.8 2.4 2.4 2.4 2.4 2.4 2.4加热辅电电流(A )8.2 8.2 8.2 10.91 10.9110.91 10.91 10.91 10.91 低温制热能力(kW )※35 6 7.1 8 910 11.2 12.5 13风扇类别及数量离心×2 离心×2 离心×2 离心×3 离心×3 离心×3 离心×3 离心×3 离心×3电机输出功率(kw ) 0.088 0.088 0.088 0.14 0.140.14 0.14 0.14 0.14 风机特标准风量(m 3/ h)1200 1200 1200 1900 19001900 2100 2100 2100 性标准静压(Pa ) 50 50 50 50 5050 50 50 50最大静压(Pa )969696969696969696室内机外形尺寸:长×宽×高(mm )990×655×3001418×655×350室内机装箱尺寸:长×宽尺寸×高(mm )1180×743×3401610×765×400面板外形尺寸:长×宽×高(mm )------ ------ ------ ------ ------ ------ ------ ------ ------面板装箱尺寸:长×宽×高(mm )------ ------ ------ ------ ------------ ------ ------ ------ 重量室内机净重/毛重(kg ) 40/46 40/46 40/46 61/68 61/6861/68 61/68 61/68 61/68 面板净重/毛重(kg ) ------------------------------------------------------节流方式电子膨胀阀线控器YR-E14/YR-E17/YR-E16/YR-E160控制器是否标配否遥控器YR-H005遥控器总成是否标配否气管(mm)¢12.7 ¢15.88 ¢15.88 ¢15.88 ¢15.88 ¢15.88 ¢15.88 ¢15.88 ¢15.88 配管尺液管(mm)¢6.35 ¢9.52 ¢9.52 ¢9.52 ¢9.52¢9.52 ¢9.52 ¢9.52 ¢9.52 寸水管(mm)¢32 ¢32 ¢32 ¢32 ¢32¢32 ¢32 ¢32 ¢32冷媒配管连接方式喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口噪音※4声压级(dB(A))43/37/35 43/37/35 43/37/35 43/37/35 43/37/3543/37/35 44/40/36 44/40/36 44/40/36 声功率级(dB(A))------------------------------------------------------※1 室内温度:27℃DB ,19℃WB/室外温度:35℃DB ,24℃WB /等效管长:7.5m ,高低差:0m ※2 室内温度:20℃DB ,14.5℃WB/室外温度:7℃DB ,6℃WB /等效管长:7.5m ,高低差:0m ※3 室内温度:20℃DB ,14.5℃WB/室外温度:2℃DB ,1℃WB /等效管长:7.5m ,高低差:0m ※4 本噪音值是在半消音室内测得的,因受周围噪音及反射声的影响,一般要高于本噪音值编制人:高静压风管机RFU (D )-A 系列参数表相当马力2.02.53.04.05.08.010.0 型号RFU(D)56MX-A RFU(D)71MX-A RFU(D)80MX-ARFU(D)90MX-A RFU(D)112MX-A RFU(D)140MX-ARFU226MX-ARFU280MX-A电源(Ph/V/Hz )单相,220V ,50Hz单相,220V ,50Hz名义制冷能力(kW )※15.67.18.0 9.0 11.2 14.022.628.0 制冷制冷输入功率(W )450450 450560 560 560600 600制冷运行电流(A )2.05 2.052.052.55 2.55 2.553.0名义制热能力(kW )※26.38.09.010.0 12.5 16.025.0 31.0制热制热输入功率(W )450450450560 560 560600600制热运行电流(A )2.052.052.052.55 2.552.553.0 3.0辅助电电热能力(kW ) 2.6 2.6 2.6 3.8 3.8 3.8 ------ ------ 加热辅电电流(A )11.9 11.9 11.9 17.317.3 17.3 ------ ------低温制热能力(kW )※35.07.18.0 10.012.5 21.525.0风扇类别及数量离心×2离心×2离心×2 离心×2离心×2离心×2离心×4 离心×4电机输出功率(kw )0.26 0.26 0.26 0.2650.265 0.265 0.238×2 0.238×2 风机特标准风量(m 3 / h)15001500 1500156016002100 40504050 性标准静压(Pa )100 100100 100100 100100 100最大静压(Pa ) 196196 196196196 196196室内机外形尺寸:长×宽×高(mm )975×906×360 1355×876×3601725×876×360室内机装箱尺寸:长×宽尺寸×高(mm )1050×945×405 1386×966×4181830×985×490面板外形尺寸:长×宽×------------------------------------------------高(mm )面板装箱尺寸:长×宽×------------------------------------------高(mm )重量室内机净重/毛重(kg )48/5862/77120/140面板净重/毛重(kg )------------------节流方式电子膨胀阀线控器YR-E14/YR-E17/YR-E16/YR-E160 控制器是否标配否遥控器YR-H005遥控器总成是否标配否气管(mm)¢12.7¢15.88¢15.88¢15.88 ¢15.88¢15.88¢25.4¢25.4 配管尺液管(mm)¢9.52¢9.52 ¢9.52¢9.52¢9.52¢9.52 ¢9.52水管(mm) ¢36 ¢36 ¢36 ¢36 ¢36 ¢36 ¢36 ¢36寸冷媒配管连接方式喇叭口喇叭口喇叭口喇叭口喇叭口喇叭口液管喇叭口/气管液管喇叭口/气管焊接焊接噪音声压级(dB(A))42/40 42/40 42/40 45/4045/40 45/40 54/49 54/49 ※4声功率级(dB(A))------------------------------------------------※1 室内温度:27℃DB ,19℃WB/室外温度:35℃DB ,24℃WB /等效管长:7.5m ,高低差:0m ※2 室内温度:20℃DB ,14.5℃WB/室外温度:7℃DB ,6℃WB /等效管长:7.5m ,高低差:0m ※3 室内温度:20℃DB ,14.5℃WB/室外温度:2℃DB ,1℃WB /等效管长:7.5m ,高低差:0m ※4 本噪音值是在半消音室内测得的,因受周围噪音及反射声的影响,一般要高于本噪音值编制人:。
TR1420 直流电源系统说明书TR1420直流电源系统说明书北京泰瑞恒业科技有限公司ITR1420直流电源系统说明书2014年1月目录1 概述 (1)2 型号说明 (1)3 TR1420高频开关整流模块及监控器 (1)3.1整流模块 (1)3.1.1功能 (1)3.1.2技术特点 (1)3.2监控器 (2)3.2.1功能 (2)3.2.2性能参数 (2)3.3功能简介 (3)3.3.1智能充电管理 (3)3.3.2电池巡检单元 (4)3.3.3绝缘检测单元 (4)3.3.4馈线监控单元 (4)3.3.5双机切换单元 (4)3.3.6温度补偿单元 (4)3.3.7辅助监控单元 (5)3.3.8通讯管理单元 (6)3.3.9故障管理单元 (6)3.4操作说明 (7)3.4.1开机 (7)3.4.2设定参数 (7)3.4.3选择运行状态 (9)3.4.4消警设定 (10)3.4.5监控 (10)3.5 TR1420系列高频开关电源模块组成的直流电源屏 (14)TR1420 直流电源系统说明书5 订货须知 (14)IIITR1420 直流电源系统 说明书 11 概述该系列直流电源是按2000版电力工程直流系统典型设计,遵照DL/T5004-95《火力发电厂、变电所、直流系统设计技术规定》,结合计算机技术和电力电子技术而设计的新型电力工程用直流电源。
适用于大型发电厂、水电厂、超高压输电变电站、无人值守变电站作为控制、信号、保护、自动化装置、自动重合闸操作事故照明、直流油泵、交流不停电电源等用电装置的直流供电电源。
该系列电源系统结构新颖、组合方便、采取功能单元和模块化设计。
整套电源系统可由直流充电整流柜、直流馈线柜,直流电源进线柜、蓄电池屏(架)柜组合而成。
2 型号说明3 高频开关整流模块及监控器3.1 整流模块3.1.1功能:● 模块化、体积小、重量轻。
● 使用软开关技术,冲击小。
● 直插式结构,维护、更换方便。
16
®
NIC COMPONENTS CORP. www www www www .SMTmagnetics.
com
Surface Mount Aluminum Electrolytic Capacitors
NACV Series
FEATURES
•CYLINDRICAL V-CHIP CONSTRUCTION FOR SURFACE MOUNT •HIGH VOLT AGE (160VDC AND 400VDC)•8 x10.8mm ~ 16 x17mm CASE SIZES •LONG LIFE (2000 HOURS A T +105O C)•DESIGNED FOR REFLOW SOLDERING CHARACTERISTICS
DIMENSIONS (mm)
CE MOUNT RoHS
Compliant
includes all homogeneous materials *See Part Number System for Details
NACV 100 M 200V 10x10.8 TR 13 F
RoHS Compliant
97% Sn (min.), 3% Bi (max.) 330mm (13”) Reel Tape & Reel Size in mm Working Voltage
T olerance Code M=20%, K=10% Capacitance Code in µF , fi rst 2 digits are signifi cant Third digit is no. of zeros, “R” indicates decimal for values under 10mF Series
PART NUMBER SYSTEM
0.3mm max.
D φ
L
+ -I
I
W
P
A
B
STANDARD PRODUCTS AND CASE SIZES (mm)
MAXIMUM RIPPLE CURRENT
(mA rms AT 120Hz AND 105°C)MAXIMUM ESR (Ω AT 120Hz AND 20°C)
Rated Voltage Range 160
200250400Rated Capacitance Range 10 ~ 82
10 ~ 68 3.3 ~ 47 2.2 ~ 22Operating Temperature Range
-40 ~ +105°C Capacitance Tolerance ±20% (M)Max. Leakage Current After 2 Minutes
0.03CV + 15µA 0.02CV + 25µA
Max. Tan δ @ 120Hz
0.200.200.200.25Low Temperature Stability
(Impedance Ratio @ 120Hz)Z-25°C/Z+20°C 3336Z-40°C/Z+20°C
66610High Temperature Load Life at 105°C
2,000 hrs φD > 10mm 1,000 hrs φD = 8mm Capacitance Change Within ±25% of initial measured value Tan δLess than 200% of specifi ed value Leakage Current
Less than the specifi ed value
Cap. (µF)Working Voltage 1602002504002.2---25
3.3--3136
4.7--3738
6.8--4447
10576464572211211211211533137137150-47180180180-68215215--82
235---Cap. (µF)Working Voltage 1602002504002.2---188.5
3.3--100.5125.7
4.7--70.688.2
6.8--48.861.0
1033.233.233.241.52215.115.115.118.83310.110.110.1-477.17.17.1-68 4.9 4.9--82
4.0---
Cap. (µF)Code Working Voltage
160200250400
2.2
2R2---8x10.83.33R3--8x10.8
10x10.84.74R7--8x10.8
10x10.86.86R8--8x10.8
12.5x14101008x10.810x10.810x10.812.5x142222012.5x1412.5x1412.5x1416x173333012.5x1412.5x1416x17-4747016x1716x1716x17-6868016x1716x17--82
820
16x17---
Case Size D φ±0.5L max.A±0.2B±0.2
I±0.2W P±0.28x10.88.010.88.38.3 2.90.7~1.0 3.210x10.810.010.810.310.3 3.2 1.1~1.4 4.612.5x1412.514.012.812.8 4.5 1.1~1.4 4.616x17
16.0
17.016.3
16.3
5.0
1.8~
2.1
7.0
PRECAUTIONS
Please review the notes on correct use, safety and precautions found on pages T10 & T11
of NIC’s Electrolytic Capacitor catalog . Also found at /precautions
If in doubt or uncertainty, please review your specifi c application - process details with
NIC’s technical support personnel: tpmg@
元器件交易网。