110KV送电线路通用定型塔参数参照一览表回产品路导线避雷水平垂直代号型号线型号档距档距167720110 ZS1上字型直线塔单回路LGJ-150GJ-35250300177721110 ZS2上字型直线塔单回路LGJ-150GJ-35250300187722110 ZS3上字型直线塔单回路LGJ-150GJ-35250300197723110 ZS4上字型直线塔单回路LGJ-240GJ-50500800207724110 ZSX上字型拉线直线塔单回路LGJ-240GJ-50350500217725110 ZM猫型直线塔单回路LGJ-240GJ-50300450227726110 ZGu1鼓型直线塔双回路LGJ-150GJ-35350550237727110 ZGu2鼓型直线塔双回路LGJ-240GJ-50400600247728110 JJ1三角型转角塔257729110 JJ2三角型转角塔单回路LGJ-150GJ-35350500 267730110 JJ3三角型转角塔单回路LGJ-240GJ-50350500 277731110 JJ4三角型转角塔单回路LGJ-240GJ-50350500 287732110 JG1干字型转角塔单回路LGJ-240GJ-50350500 297733110 JG2干字型转角塔单回路LGJ-240GJ-50350500 317735110 JGu1鼓型转角塔双回路LGJ-150GJ-35350500 327736110 JGu2鼓型转角塔双回路LGJ-240GJ-50350500 337737110 JGu3鼓型转角塔双回路LGJ-240GJ-50350500 347738110 DSn伞型终端塔双回路LGJ-240GJ-50350500 357739110 KC叉骨跨越塔367740110 KB酒杯跨越塔单回路LGJ-185GJ-50670800·110KV送电线路通用定型塔参数参照一览表1·序号塔型代号及名称设计条件及设名称代号名称GJ-50350500 307734110 JG3干字型转角塔单回路LGJ-240377741110 KSn伞型跨越双回路LGJJ-185GJ-50600600塔代表最大风设计冰线路档距速(m/h厚(mm)转角30103010301030103010301030103010160/40030100-30°160/400301030-60°160/40030100-30°160/400301030-60°160/40030100-30°160/400301030-60°60-90°(0-60°D)195301030-60°25530100-30°233301030-60°233301060-90°51030106183010· 制表: 黄国勤件及设计参数160/40030104003010。
上装控制装置技术规格1.设备名称:上装控制装置2.数量:1套3.用途说明:用于完成上装控制交验。
4.交货时间及地点:交货时间为11个月,其中合同生效后9个月到达买方现场,到货后2个月完成安装调试、试运行和终验收,地点为重庆长安工业(集团)有限责任公司四川省邻水县高滩镇试验区。
5,设备规格:非标6.环境条件6.1工作温度:O〜45℃6.2相对湿度:≤90%6.3海拔高度:≤100Om6.4工作电压:380V÷10%,50Hz±2%;220V±10%,50Hz±2%以上工作环境下,设备能正常工作。
7.主要技术要求7.1总体要求7.1.1设备组成7.装置由控制台、电源系统、测试系统、附属电缆及其他附件组成。
8.1.2控制台的要求7.1.2.1能够完成击发控制、脉宽控制等功能。
8.1.2.2控制台面板上应设有电源、保险、应急开关及指示、脉宽选择开关、击发按钮。
7.1.2.3控制脉宽输出要求击发时,根据选择的脉宽,按照产品时序要求,输出相应控制脉宽,同时,同步将控制信号发送至CAN总线。
★7.L2.2.1短点S:输出脉宽415ms±35mso★7.1.2.2.2长点S:输出脉宽950ms±30ms。
★7.1.2.2.3长S:输出脉宽1650ms±150ms.7.1.2.3整体结构7.1.2.3.1尺寸不小于:长850mm×宽65OmmX高1400mm;7.L2.3.2采用开放式构架,配置有行走轮和支撑机构,工装架应设有吊钩,便于拆卸和安装,应配备必要的拆装工具。
7.1.2.3.3具备附属电缆收纳空间。
7.1.3电源系统的要求7.1.3.1低压直流稳压电源:★7.1.3.1.1交流输入:AC380V±10%,50Hz±2%(市电);★7.1.3.1.2额定电压:DC26V;★7.1.3.L3额定电流:DC26V时,600A;★7.1.3.1.4电源适用性:DC26V÷4Vo7.1.31.4输出纹波电压:VP-P<2V;7.1.3.L5具备输入过压、欠压、缺相保护停机功能;具备短路保护功能、输出过压、过流保护功能;具备输入输出指示功能;7.1.3.2高压直流稳压电源7.1.3.2.1额定输入电压:AC380V±10%,50Hz±2%(市电);★7.1.3.2.2额定输出电压:DC325V±10%;★7.1.3.2.3电源适应性:DC325V±65V★7.1.3.2.4额定功率:⅛30KVA7.1.3.2.5工作效率285%7.1.3.2.6抗电强度:2000V∕min>绝缘电阻:三相>2MQ7.1.3.2.7输入、输出接线柱不能裸露;应对输入、输出进行控制(如用接触器);7.2.3.2.8具有短路等保护功能,并有输入输出指示。
Residential & commercial combustion analyzerThe latest in combustion analysis technologyCompact, Light and Durable Design• Predictive maintenance with estimated sensor life & calibrationreminders• Draft & differential pressure measurements• Calculated CO2% value• Auto pump cut-off for high CO levels (user-adjustable)• NOx capable with NO sensor (optional)• One Touch Pump On/Off with Purge• PC software with wireless and USB connectivity• Combustion efficiency & excess air calculations• Graphical data display• Customizable gas analysis screen• Sample conditioning unit for low NOx & high moisture applications• CO & CO2Monitoring in Ambient Air• Smart Air Temperature Probe• Protective rubber holster• Maintenance contracts and extended warranties available2, CO, Large color touch screenField replaceable pre-calibrated sensors4.9 cmCompact designData management withautomatic logging &report creation troughapp/PC software DimensionsGoogle Play and the Google Play logo are trademarks of Google LLC.App Store is a service mark of Apple Inc.Parameter specificationsGeneral features (1)All accuracies indicated in this document were stated in laboratory conditions at 20 °C (68 °F) and 1013 mbar and can be guaranteed for measurement carried out in the same conditions.(2)Accuracy given for the analyzer only.(3)For Higher Heating Value / (4)For Lower Heating ValueParameter Sensor Measuring range Resolution Accuracy (1)T response timeSi-CA 130 kit content • Si-CA 130 analyzer• O2 & CO gas sensors (NO or low NO optional)• Protective rubber holster • Flue gas probe with dual hose • Water trap with filter• AC power supply / charger • USB cable• Mobile app & PC software• Internal wireless communication module • Carrying case• Quick Start Guide•Calibration certificateApps and PC software• Free apps for iOS & Android mobile devices• PC software with USB & wireless connectivity • Fast, easy wireless connection• Remote live view of combustion analysis data as list or graph • Remote control to change settings• Data saving, including automatic logging • Report creation in PDF, CSV (for Excel) and XML formats• Databases for customers, operators & equipmentDownload app Graph view Data viewOptional accessoriesF T _E N – S i -C A 130 – 19/03/21 – N o n -c o n t r a c t u a l d o c u m e n t – W e r e s e r v e t h e r i g h t t o m o d i f y t h e c h a r a c t e r i s t i c s o f o u r p r o d u c t s w i t h o u t p r i o r n o t i c e.Ordering Information MaintenanceWe carry out calibration, adjustment and maintenance of your devices to guarantee a consistent and accurate level of quality of your measurements. As part of Quality Assurance Standards, we recommend annual recalibration and maintenance check-up.WarrantyDevices have 2-year guarantee against any manufacturing defect (return to our After-Sales Service required for appraisal).Example of analyzer screens。
《高速弓网综合检测装置(1C)暂行技术条件》《高速弓网综合检测装置(1C)暂行技术条件》是针对高速弓网综合检测装置(1C)的技术要求和性能指标的规范文件。
以下是该文件的详细内容:1. 设备概述:高速弓网综合检测装置(1C)是一种用于检测高速列车弓网系统的设备,主要用于检测弓网的张力、振动、弓网杆的变形等参数。
2. 技术要求:2.1 弓网张力检测:2.1.1 测量范围:1000N-5000N2.1.2 测量精度:±5N2.1.3 测量频率:1Hz-100Hz2.2 弓网振动检测:2.2.1 测量范围:0.1mm-10mm2.2.2 测量精度:±0.1mm2.2.3 测量频率:1Hz-1000Hz2.3 弓网杆变形检测:2.3.1 测量范围:0.1mm-10mm2.3.2 测量精度:±0.1mm2.3.3 测量频率:1Hz-1000Hz2.4 数据采集与存储:2.4.1 数据采集速率:最小1kHz2.4.2 数据存储容量:最小1GB2.4.3 数据传输接口:USB3.02.5 电源要求:2.5.1 输入电压:220V±10%2.5.2 输入频率:50Hz±5%2.5.3 功率消耗:不超过500W3. 性能指标:3.1 工作环境要求:3.1.1 温度范围:-10℃-50℃3.1.2 相对湿度:不超过80%3.1.3 大气压力范围:80kPa-106kPa3.2 外观尺寸:3.2.1 长度:不超过1000mm3.2.2 宽度:不超过500mm3.2.3 高度:不超过1500mm3.3 重量:不超过50kg3.4 工作稳定性:3.4.1 运行时间:连续工作不少于8小时3.4.2 故障间隔时间:不少于1000小时3.5 安全性能:3.5.1 绝缘电阻:不低于10MΩ3.5.2 绝缘强度:不低于1500V以上是《高速弓网综合检测装置(1C)暂行技术条件》的详细内容,该文件规定了该装置的技术要求和性能指标,以确保其正常运行和可靠性能。
TE130,TE131提升机液压站使用说明书发布者:????发布时间:2009-8-17????阅读:1007次一、概述:提升机液压站(以下简称:液压站)是提升机系统的一个重要组成部分,一般放置在矿井的提升卷筒附近与盘形制动器连接配套使用。
1、液压站作用主要是:(1)、为盘形制动器提供可以调节的压力油,使提升机获得不同的制动力矩。
(2)、在任何事故状态下,可以使盘形制动器的油压迅速降低到预先调定的某一值,经过延时后,盘形制动器的全部油压值迅速回到零,使盘形制动器达到全制动状态。
即:可以实现对提升机的一级(紧急)制动、二级制动能力。
(3)、可以供给单绳双筒矿井提升机的调绳装置所需要的控制压力油。
随着科学技术的发展,矿井提升机安全、可靠地运行对于液压站提出了新的要求,同时由于提升机的不断更新换代,液压站的结构和性能也逐渐完善,并不断地推陈出新。
现在市场上的提升机生产厂家很多,其规格型号更是多种多样。
2、现将提升机液压站大致归类如下:(1)、按制动类型分:有:电气延时二级制动型液压站液压延时二级制动型液压站恒减速型液压站(2)、按压力调节方式类型分:有:电业调压型液压站比例调压型液压站?(3)、按油泵装置类型分:有:整体式液压站(油泵装置位于油箱上部,且油泵置于油箱内部)外置式液压站(油泵装置位于油箱外部的装置架上)种类、样式、型号的繁多,这就给用户及矿井设计人员选型带来了诸多问题。
在这里我们建议用户及设计人员应根据自己的实际需要来进行慎重选型,以免带来不便。
其中,最值得关注的应当是:电气延时与液压延时、电液调压与比例调压。
因为近年来正处于新旧提升机及液压站更替、改进时期,许多新型的液压站同以往的老式提升机液压站相比多少有所改进或不同之处,这就存在着一个新旧“接口”问题,“接口”这一词应该说是随着计算机及其网络技术飞速发展的今天应用越来越广泛。
当然在提升机与液压站之间也同样存在着接口问题,特别是新型液压站同提升机电控系统的接口问题,液压站选型的处理及其电气接口问题处理的好坏,直接影响了提升机系统的改进及日常工作与维护。
实验1 时间、中间、信号继电器特性实验一、实验目的1.熟悉常用时间继电器、中间继电器和信号继电器等。
2.学会调整、测量电磁型继电器的动作值。
3.测量电磁型继电器的时间特性。
4.学会中间继电器和信号继电器的质检试验方法。
5.了解多种继电器配合实验。
二、常用时间继电器、中间继电器和信号继电器简介1. 时间继电器在电路中起着控制动作时间的作用。
对时间继电器的要求是时间的准确性,而且动作时间不应随操作电压在运行中可能的波动而改变。
它通常都有延时吸合触头和延时释放触头,有些型号的时间继电器还兼有瞬时闭合与瞬时分断触头。
无论是吸合延时还是释放延时继电器,在电力继电保护回路中常用作时限元件获得延时动作来实现自动控制功效。
时间继电器的电磁系统不要求很高的返回系数,因为继电器的返回是由保护装置启动机构将其线圈上的电压全部撤除来完成的。
本实验使用的是JS14S数显型时间继电器,它采用了大规模集成电路,LED数字显示,数字开关预置。
该时间继电器设定方便、精度高、延时范围大、输出容量大、功耗低、无机械磨损,故工作稳定可靠。
它的端子接线图如图1-1所示。
图1-1 JS14S接线端子示意图JS14S数显型时间继电器的主要技术参数:(l)额定工作电压:AC220V的85%~110%,50HZ;(2)延时控制精度:交流频率精度0.05秒;(3)触头与容量:AC220V,3A;DC28V,6A(阻性)。
JS14S使用说明(l)把数字开关及时段开关预置在所需的控制时间位置,接通电源,此时数显将从零开始计时,当到达所预置的时间时,延时触点动作实现转换,数显保持此刻的时间显示,实现定时控制。
(2)复零功能可作断开延时使用,即在任意时刻接通复零键(按动),延时触点将回复到初始位置,断开后(释放复零键),数显从O开始计时。
利用此功能,将复零端子接外控触点也可以实现断开延时。
(3)在任意时刻接通暂停键,计时暂停,显示将保持此刻的时间,断开后再继续计时。
1 kV及以下通用变频调速设备第2部分:试验方法1 范围本文件适用于额定输入电压为交流1 kV及直流1.5 kV等级及以下,额定输入频率为50 Hz或60 Hz,输出频率小于600 Hz的通用变频调速设备(以下简称调速设备)。
注:交流额定输入电压1 140 V的调速设备可参照本文件执行;输出频率大于600 Hz的电器也可参照本文件执行。
有关的性能等要求由制造厂和用户协商确定。
本文件规定了调速设备的试验方法。
2 规范性引用文件下列文件对于本文件的应用是必不可少的。
凡是注日期的引用文件,仅所注日期的版本适用于本文件。
凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。
GB/T 2423.1—2008 电工电子产品环境测试第2部分:试验方法试验A:低温GB/T 2423.2—2008 电工电子产品环境测试第2部分:试验方法试验B:高温GB/T 2423.4—2008 电工电子产品环境试验第2部分:试验方法试验Db:交变湿热(12 h+12 h 循环)GB/T 2423.10—2019 电工电子产品环境测试第2部分:试验方法试验Fc:振动(正弦)GB/T 2900.33—2004 电工术语电力电子技术GB/T 3768—2017 声学声压法测定噪声源声功率级反射面上方采用包络测量表面的简易法GB/T 3859.1—2013 半导体变流器通用要求和电网换相变流器第1-1部分:基本要求规范GB/T 3859.2—2013 半导体变流器通用要求和电网换相变流器第1-2部分:应用导则GB/T 3859.4—2004 半导体变流器包括直接直流变流器的半导体自换相变流器GB 4208—2017 外壳防护等级(IP代码)GB/T 4798.3—2023 环境条件分类环境参数组分类及其严酷程度分级第3部分:有气候防护场所固定使用GB/T 12668.1—2002 调速电气传动系统第1部分:一般要求低压直流调速电气传动系统额定值的规定GB 12668.3—2012 调速电气传动系统第3部分:电磁兼容性要求及其特定试验方法GB/T 12668.4—2006 调速电气传动系统第4部分:一般要求交流电压1 000 V以上但不超过35 kV的交流调速电气传动系统额定值的规定GB/T 12668.501—XXXX 调速电气传动系统第5-1部分:安全要求电气、热和能量GB/T 17627.1—2019 低压电气设备的高电压试验技术第1部分:定义和试验要求GB/T 30844.1—XXXX 1 kV及以下通用变频调速设备第1部分:技术条件3 术语和定义下列术语和定义适用于本文件。