当前位置:文档之家› 暖通专业毕业设计开题报告

暖通专业毕业设计开题报告

暖通专业毕业设计开题报告
暖通专业毕业设计开题报告

河南理工大学本科毕业设计开题报告

暖通空调设计毕业设计说明书

摘要 本设计为哈尔滨望江集团办公楼空调系统工程设计。哈尔滨望江集团办公楼属中小型办公建筑,本建筑总建筑面积4138m2,空调面积2833m2。地下一层,地上八层,建筑高度33.9m。全楼冷负荷为191千瓦,全楼采用水冷机组进行集中供给空调方式。 此设计中的建筑主要房间为办公室,大多面积较小,且各房间互不连通,应使所选空调系统能够实现对各个房间的独立控制,综合考虑各方面因素,确定选用风机盘管加新风系统。在房间内布置吊顶的风机盘管,采用暗装的形式。将该集中系统设为风机盘管加独立新风系统,新风机组从室外引入新风处理到室内空气焓值,不承担室内负荷。风机盘管承担室内全部冷负荷及部分的新风湿负荷。风机盘管加独立新风系统由百叶风口下送和侧送。水系统采用闭式双管同程式,冷水泵三台,两用一备;冷却水泵选三台,两用一备。 在冷负荷计算的基础上完成主机和风机盘管的选型,并通过风量、水量的计算确定风管路和水管路的规格,并校核最不利环路的阻力和压头用以确定新风机和水泵。 依据相关的空调设计手册所提供的参数,进一步完成新风机组、水泵、热水机组等的选型,从而将其反应在图纸上,最终完成整个空调系统设计。 关键词:风机盘管加独立新风系统;负荷;管路设计;制冷机组:冷水机组

Abstract The design for the Harbin Wangjiang Design Group office building air conditioning system. Harbin Wangjiang Group is a small and medium-sized office building office buildings, the total floor area of building is 4138m2, air-conditioned area is 2833m2. There are eight floor of the building, building height is 33.9m. Cooling load for the entire floor, 191 kilowatts, the whole floor using Central Cooling Chillers to focus on the way . This design of the main room of the building for office, most of them is very small, and the rooms are not connected, the selected air-conditioning system should be able to achieve independent control of each room, considering the various factors to determine the selection of fan-coil plus fresh air system. Arrangement in the room ceiling fan coil units, using the dark form of equipment. Set the focus on fan-coil system, plus an independent air system, fresh air from the outdoor unit to deal with the introduction of a new wind to the indoor air enthalpy value, do not bear the load of indoor. All bear the indoor fan-coil cooling load and part of its new rheumatoid load. Fan-coil plus an independent air system sent by the Venetian and the under side air delivery. Closed water system with a dual-track program, three cold-water pump, dual-use a prepared; cooling pumps three elections, one prepared by dual-use. In the cooling load calculation based on the completion of the selection of host and fan coil units, and air volume, the calculation of water, the wind pipe and water pipes to determine the specifications of the road and check the resistance to the most disadvantaged and the loop to determine the pressure head new fans and pumps. Based on the relevant manuals provided by air-conditioning design parameters, and further completion of the new air units, water pumps, hot water units, such as the selection, which will be reflected in their drawings, the final design of the entire air-conditioning system Key words: PAU+FCU systems; load; pipeline design; refrigeration machine; Chillers

暖通空调毕业设计

1.工程概况及主要设计参数 (1) 1.1 工程概况 (1) 1.2 基本设计参数 (1) 1.3 设计依据 (3) 2.空调系统的负荷计算 (3) 2.1空调房间的冷负荷计算 (3) 2.2湿负荷计算 (8) 2.3热负荷计算 (9) 3系统方案确定 (18) 3.1系统的分区 (18) 3.2空调系统的分类 (19) 3.3空调系统的比较 (20) 3.4空调系统方式的确定 (24) 3.4 空调房间送风量的确定 (27) 3.5空气处理设备选型 (29) 4.室内气流组织形式的确定及计算 (33) 4.1 送、回风口的型式 (33) 4.2 气流组织形式 (35) 4.3 气流组织的设计计算 (38) 5水系统设计 (44) 5.1水系统简介 (44) 5.2水系统的管路设计计算 (49) 5.4空调水系统水力计算 (51) 5.5系统管材的选择 (54) 6.风管的布置及其水力计算 (55) 6.1风管设计的基本知识 (55) 6.2风管的水力计算 (58) 7.空调制冷机房设计 (63) 7.1空调冷水系统 (63) 7.2热水循环系统.................................................................................. - 66 - 7.3冷冻水系统设计.............................................................................. - 68 - 7.4冷却水系统...................................................................................... - 71 - 7.5循环水系统的补水、定压与膨胀.................................................. - 74 - 7.6 管道的水力计算............................................................................. - 76 -8系统保温及消声、减震........................................................... - 79 - 8.1管道及设备的保温.......................................................................... - 79 -

暖通空调毕业设计开题报告

1.课程设计的意义 通过本次的课程设计,使自己拥有一定的暖通空调设计能力;了解一些相关的规范和条例;熟悉并掌握暖通空调设计流程;同时使自己的思维更加的严谨,态度更加的认真,为以后的社会工作奠定了扎实的基础。 2.文献综述 随着国民经济的快速持续发展,作为支柱产业之一的建筑业也得到迅猛发展。而作为建筑业的重要组成部份的暖通空调业,其新产品、新技术、新材料更是层出不穷。暖通空调业发展所遵循的原则,概括起来就是:节能、环保、可持续发展,保证建筑环境的卫生与安全,适应国家的能源结构调整战略,贯彻热、冷计量政策,创造不同地域特点的暖通空调发展技术。因此,如何结合设计的需要,重视相关技术,并有选择而合理的应用在我们的设计中,满足业主要求,提高设计水平,是我们必须努力做到的。 2.1.暖通空调变工况点优化控制及能量管理探讨 2.1.1.工况点优化控制 暖通空调变工况点优化控制问题的研究近年来在我国被重视。S.W.Wang 提出了一种基于整个系统环境的预测响应及能量运行来改变暖通空调系统控制,设定点的系统方法,并用遗传算法对系统进行优化控制,同时优化多个设定点来改善系统响应和降低系统能耗[1],后来他又采用自适应性控制理论对某海水冷却。空调系统进行了优化控制研究,采用带指数遗忘的最小二乘法参数辨识方法和基因遗传优化算法,对空调系统的空气处理单元进行了优化控制研究[2]。罗启军等人提出了一项动态的优化技术在一个指定期间内,能得到使目标函数( 运行成本或者峰值能耗) 最小的房间温度曲线,该算法还给出了暖通空调设备的最佳开/关时间[3]。K.T.Chan 等人提出用遗传算法对风冷制冷机的冷凝温度设定点进行优化控制以提高制冷机的效率[4]。此外,有许多研究者用人工神经网络来模拟暖通空调系统中各个设备的非线性特性,用于实现对整个空调系统的优化控制。目前,研究者们将更多先进的建模方法和智能优化方法引入到了暖通空调的优化控制中,更加注重变工况点的在线优化控制。何厚建等人对已建的暖通空调各关键设备的静态模型采用用实数编码的遗传算法建立了水系统工作点优化控制策略[5]杨晓平等人采用模糊聚类和RBF方法建立了空气处理单元的动态数学模型,以最终舒适性为目标优化空气处理单元的温湿度和送风压力[6]。孙一坚根据空调负荷变化对一级泵水系统进行变流量控制,取得了显著效果[7]。总之国内的学者更多探讨的是把智能方法引入控制系统的优化中,仿真研究多,实践成果少。

2021年暖通空调毕业设计开题报告模板

暖通空调毕业设计开题报告模板 暖通空调毕业设计开题报告模板 无论是课题的,还是的写作,都是与开题报告密切相关的,今 天带来一篇暖通空调毕业设计开题报告,希望给大家提供一定的帮助。 通过本次的课程设计,使自己拥有一定的暖通空调设计能力; 了解一些相关的规范和条例;熟悉并掌握暖通空调设计流程;同时使 自己的思维更加的严谨,态度更加的认真,为以后的社会工作奠定了扎实的基础。 随着国民经济的快速持续发展,作为支柱产业之一的建筑业也 得到迅猛发展。而作为建筑业的重要组成部份的暖通空调业,其新产品、新技术、新材料更是层出不穷。暖通空调业发展所遵循的原则,概括起来就是:节能、环保、可持续发展,保证建筑环境的卫生与安全,适应国家的能源结构调整战略,贯彻热、冷计量政策,创造不同地域特点的暖通空调发展技术。因此,如何结合设计的需要,重视相关技术,并有选择而合理的应用在我们的设计中,满足业主要求,提高设计水平,是我们必须努力做到的。 暖通空调变工况点优化控制问题的研究近年来在我国被重视。S.W.Wang 提出了一种基于整个系统环境的预测响应及能量运行来改

变暖通空调系统控制,设定点的系统方法,并用遗传算法对系统进行优化控制,同时优化多个设定点来改善系统响应和降低系统能耗???,后来他又采用自适应性控制理论对某海水冷却。空调系统进行了优化控制研究,采用带指数遗忘的最小二乘法参数辨识方法和基因遗传优化算法,对空调系统的空气处理单元进行了优化控制研究???。罗启军等人提出了一项动态的优化技术在一个指定期间内,能得到使目标函数( 运行成本或者峰值能耗) 最小的房间温度曲线,该算法还给出了暖通空调设备的最佳开/关时间???。K.T.Chan 等人提出用遗传算法对风冷制冷机的冷凝温度设定点进行优化控制以提高制冷机的效率???。此外,有许多研究者用人工神经网络来模拟暖通空调系统中各个设备的非线性特性,用于实现对整个空调系统的优化控制。目前,研究者们将更多先进的建模方法和智能优化方法引入到了暖通空调 的优化控制中,更加注重变工况点的在线优化控制。何厚建等人对已建的暖通空调各关键设备的静态模型采用用实数编码的遗传算法建 立了水系统工作点优化控制策略???杨晓平等人采用模糊聚类和RBF 方法建立了空气处理单元的动态数学模型,以最终舒适性为目标优化空气处理单元的温湿度和送风压力???。孙一坚根据空调负荷变化对一级泵水系统进行变流量控制,取得了显著效果???。总之国内的学者更多探讨的是把智能方法引入控制系统的优化中,仿真研究多,实践成果少。

毕业设计开题报告及文献综述

毕业设计开题报告及 文献综述 Revised on November 25, 2020

华北电力大学 毕业设计(论文)开题报告 学生姓名:宗均恺班级:建环13K2 所在院系:动力工程系 所在专业:建筑环境与能源应用工程 设计(论文)题目:石家庄某接待中心中央空调系统设计指导教师:刘志坚 2017年 3月 5 日 毕业设计(论文)开题报告

保定某中型商场暖通空调系统设计 1 选题背景及意义 暖通空调(HVAC)技术发展概况和前景[8] 建筑是人们生活与工作的场所。现代人类大约有五分之四的时间在建筑中度过。人们已经逐渐认识到,建筑对人类寿命、工作效率、产品质量起到极为重要的作用。人类在从穴居到居住现代环境的漫长发展道路上,始终不懈的改善室内环境,以满足人类自身生活、工作对环境的要求和生产、科学实验对环境的要求。人们对建筑的要求不只有挡风遮雨的功能,而且还应是一个温湿度怡人、空气清新、光照柔和、宁静舒适分环境。生产与科学是经验对环境提出了更为严苛的条件,如计算室或标准量具生产环境要求温度恒定,纺织车间要求湿度恒定,有些合成纤维的生产要求恒温恒湿,半导体期间、磁头、磁鼓生产要求对环境的灰尘有严格的控制,抗菌素生产与分装、大输液生产、无菌试

验动物饲养等要求无菌环境,等等。这些人类自身对环境的要求和生产、科学实验对环境的要求导致了建筑环境的控制计术的产生与发展,并且已形成了一门独立的学科。建筑按环境学指出,建筑环境由热湿环境、室内空气品质、室内光环境和声环境组成。采暖通风与空气调节是控制建筑热湿环境和室内空气品质的技术,同时也包含对系统本身所产生的噪声的控制。 随着时代的发展,人们对生产生活的建筑环境提出了越来越高的要求,同时由于能源紧缺,环境污染严重等问题也对建筑提出了节能减排的要求。等等这些问题就要求我们暖通人把握自身专业,顺应潮流发展,在未来利用所学成就自我成就暖通这个行业。 现代中大型接待中心的空调设计探讨 随着改革开放及经济建设的发展,我国商业建筑大量兴建,招待所、宾馆的数量也与日俱增。我国早期建起的招待所以及宾馆普遍存在着忽略室内环境品质或者夏季空调不足、能耗过大、室内空气品质差等问题。近年来,由于人们对居住品质的高要求以及旅游业的带动和宾馆产业的发展,大型宾馆,连锁旅店得到了迅速的发展,同时对宾馆环境提出了更高要求。 宾馆、酒店不同于商场等场所,它具有它自身的特点; 1)宾馆是由大厅和客房组成,由于大厅和多功能厅和客房的使用情况不同就对空调系统提出了不同的要求,要分别采用合适其特点的的系统和机组; 2)客房是个相对封闭的环境对新风要求比较高,需要不同于其他建筑的新风品质。 3)由于客房是居住环境以及宾馆品级,对室内温湿度要求比较严格。

暖通空调毕业设计(论文)任务书

毕业设计(论文)任务书 毕业设计(论文)题目:某市某综合楼空调系统设计 系别能源与动力学院班级建环本121/122 学生姓名学号 指导教师职称 毕业设计(论文)进行地点:校内 任务下达时间: 2015年 12 月 24 日 起止日期:2016年 3 月1日起——至 2016年 6 月日止 教研室主任年月日批准 1、论文的原始资料及依据:

(一)题目来源:某市某综合楼建筑结构图 (二)设计主要技术参数 (1)土建资料 详见建筑图纸。 (2) 气象参数:根据本市的气象资料确定; (3)建筑参数: 外墙体结构:根据地区自行选定,如δ=370 m m红砖,内外抹灰20mm 屋面:根据地区自行选定,如200mm厚混凝土板加12.5mm厚加气混凝土保温层。 外窗:根据地区自行选定,如标准玻璃的单层钢窗,全部挂淡色窗帘,(4)室内空调设计参数:温度t n=26℃; 湿度φn=60%; 风速不大于0.3 m/s。 (5)照明容量: 40W/m2 (6)房间人数:0.5人/m2,群集系数0.92 (三)设计主要技术关键 正确进行空调负荷和新风量的计算,确定出冷气方案,合理地布置管道,并进行水力计算,合理选择及布置设备,做好气流组织。 2、设计(论文)主要内容及要求 通过本次设计使学生系统地掌握空调系统设计的主要方法和步骤,能根据实际情况合理确定空调方案,会计算空调系统的负荷量和新风负荷量,能合理布置管道和设备,了解空调设备的型式及用途,会进行设备的选型,合理进行气流组织,会计算水管、风道的阻力,选取水泵、风机等。使学生能把所学知识灵活运用到实际当中去,让理论与实际相结合,为学生毕业以后的工作打下坚实基础。 主要内容: 空调系统的设计 (1)、由建筑物所在地区确定室内外气象参数; 夏季室内外设计计算参数;室内温度、湿度、风速、新风量等参数。

暖通毕业设计开题报告

暖通毕业设计开题报告 Document serial number【KKGB-LBS98YT-BS8CB-BSUT-BST108】

毕业设计(论文)开题报告 题目:永州商业广场综合楼中央空调系统设计 学院:建筑工程学院 专业:建筑环境与设备工程 学生姓名: xx 学号: 14 指导老师: xxx 2016年 3月 30日 开题报告填写要求 1.开题报告(含“文献综述”)作为毕业设计(论文)答 辩委员会对学生答辩资格审查的依据材料之一。此报告应在指 导教师指导下,由学生在毕业设计(论文)工作前期内完成, 经指导教师签署意见及所在专业审查后生效。 2.开题报告内容必须用黑墨水笔工整书写或按此电子文档 标准格式(可从教务处网页上下载)打印,禁止打印在其它纸 上后剪贴,完成后应及时交给指导教师签署意见。 3.“文献综述”应按论文的格式成文,并直接书写(或打 印)在本开题报告第一栏目内,学生写文献综述的参考文献应 不少于10篇(不包括辞典、手册),其中至少应包括1篇外文 资料;对于重要的参考文献应附原件复印件,作为附件装订在 开题报告的最后。 4.统一用A4纸,并装订单独成册,随《毕业设计(论 文)说明书》等资料装入文件袋中。 毕业设计(论文)开题报告

3、冰蓄冷中央空调 冰蓄冷中央空调是由冰提供冷源的中央空调系统,相对于常规中央空调增加一个蓄冰装置。冰蓄冷中央空调可以减缓用电高峰紧张,而且比常规空调系统每年节约运行费用10%-30%。 目前世界发达国家都已经或正在使用冰蓄冷空调,我国目前实施推广的省、市有北京、湖北、河南、湖南、江苏、浙江、广东等,尤其是在以广东为中心的华南地区,每年使用中央空调的时间长达9-10个月,使用冰蓄冷空调无论在经济效益上,还是社会效益上,意义更为重大。 四、中央空调的发展趋势 中央空调系统有三种主要形式: 中央空调是集中处理空调负荷的系统型式,其冷/热量是通过一定的介质输送到空调房间里去的。按照家用小型中央空调的输送介质的不同,常见的家用小型中央空调可以分成以下三种主要型式。 风管式系统:风管式系统以空气为输送介质,其原理与大型全空气中央空调系统的原理基本相同,是一个小型化的全空气中央空调系统。它利用室外主机集中产生冷/热量,将从室内引回的回风进行冷却/加热处理后,再送入室内消除其空调冷/热负荷。相对于其它的家用小型中央空调型式,风管式系统初投资较小。如若引入新风,其空气品质能得到较大的改善。但风管式系统的空气输配系统所占用建筑物空间较大,一般要求住宅要有较大的层高。而且它采用统一送风的方式,在没有变风量末端的情况下,难以满足不同房间不同的空调负荷要求。而变风量末端的引入将会使整个空调系统的初投资大大增加。 冷/热水机组:冷/热水机组的输送介质通常为水或乙二醇溶液,它的基本原理与通常所说的风机盘管系统类似。通过室外主机产生出空调冷/热水,由管路系统输送至室内的各末端装置,在末端装置处冷/热水与室内空气进行热量交换,产生出冷/热风,从而消除房间空调负荷。它是一种集中产生冷/热量,但分散处理各房间负荷的空调系统型式。该系统的室内末端装置通常为风机盘管。目前风机盘管一般均可以调节其风机转速,从而调节送入室内的冷/热量,因此该系统可以对每个空调房间进行单独调节,满足不同房间不同的空调需求,同时其节能性也较好。此外,由于冷/热水机组的输配系统所占空间很小,因此一般不受住宅层高的限制。但此种系统一般难以引进新风,因此对于通常密闭的空调房间而言,其舒适性较差。

暖通空调专业-毕业设计外文翻译

Refrigeration System Performance using Liquid-Suction Heat Exchangers S. A. Klein, D. T. Reindl, and K. BroWnell College of Engineering University of Wisconsin - Madison Abstract Heat transfer devices are provided in many refrigeration systems to exchange energy betWeen the cool gaseous refrigerant leaving the evaporator and Warm liquid refrigerant exiting the condenser. These liquid-suction or suction-line heat exchangers can, in some cases, yield improved system performance While in other cases they degrade system performance. Although previous researchers have investigated performance of liquid-suction heat exchangers, this study can be distinguished from the previous studies in three Ways. First, this paper identifies a neW dimensionless group to correlate performance impacts attributable to liquid-suction heat exchangers. Second, the paper extends previous analyses to include neW refrigerants. Third, the analysis includes the impact of pressure drops through the liquid-suction heat exchanger on system performance. It is shoWn that reliance on simplified analysis techniques can lead to inaccurate conclusions regarding the impact of liquid-suction heat exchangers on refrigeration system performance. From detailed analyses, it can be concluded that liquid-suction heat exchangers that have a minimal pressure loss on the loW pressure side are useful for systems using R507A, R134a, R12, R404A, R290, R407C, R600, and R410A. The liquid-suction heat exchanger is detrimental to system performance in systems using R22, R32, and R717. Introduction Liquid-suction heat exchangers are commonly installed in refrigeration systems With the intent of ensuring proper system operation and increasing system performance.Specifically, ASHRAE(1998) states that liquid-suction heat exchangers are effective in: 1) increasing the system performance 2) subcooling liquid refrigerant to prevent flash gas formation at inlets to expansion devices 3) fully evaporating any residual liquid that may remain in the liquid-suction prior to reaching the compressor(s) Figure 1 illustrates a simple direct-expansion vapor compression refrigeration system utilizing a liquid-suction heat exchanger. In this configuration, high temperature liquid leaving the heat rejection device (an evaporative condenser in this case) is subcooled prior to being throttled to the evaporator pressure by an expansion device such as a thermostatic expansion valve. The sink for subcooling

暖通毕业设计开题报告

题目:永州商业广场综合楼中央空调系统设计 学院:建筑工程学院 专业:建筑环境与设备工程 学生姓名: xx 学号: 201209010114 指导老师: xxx 2016年3月30日

开题报告填写要求 1.开题报告(含“文献综述”)作为毕业设计(论文)答辩委员会对学生答辩资格审查的依据材料之一。此报告应在指导教师指导下,由学生在毕业设计(论文)工作前期内完成,经指导教师签署意见及所在专业审查后生效。 2.开题报告内容必须用黑墨水笔工整书写或按此电子文档标准格式(可从教务处网页上下载)打印,禁止打印在其它纸上后剪贴,完成后应及时交给指导教师签署意见。 3.“文献综述”应按论文的格式成文,并直接书写(或打印)在本开题报告第一栏目内,学生写文献综述的参考文献应不少于10篇(不包括辞典、手册),其中至少应包括1篇外文资料;对于重要的参考文献应附原件复印件,作为附件装订在开题报告的最后。 4.统一用A4纸,并装订单独成册,随《毕业设计(论文)说明书》等资料装入文件袋中。

毕业设计(论文)开题报告 文献综述 一、引言 随着我国人民生活水平的不断提高,购买力增强。近年来修建了不少商业建筑,并且向多元化方向发展,建筑规模越来越大。装饰豪华、营销全面、多维服务,集商贸、娱乐、居住、办公为一体的高级商城也层出不穷。 商业建筑是一个流动人口众多的公共场所,室内空气的温湿度、洁净度和新鲜空气量等,对顾客和商场职工的身体健康影响很大。因此,商业建筑的空气环境越来越被商业部门所重视。我国卫生防疫部门对商业建筑提出了卫生要求,对较大的重点商场还进行过监测,对一些已建的大中商场要求进行改造,增设通风设施或加建空气调节装置。新建的大中商业建筑纷纷安装了空调系统,以提高商场的档次,吸引更多的顾客。各大城市中频频展开的“商战”更加速了空调系统在商业建筑中的普及。 商业建筑不断的增多,以及人们对室内空气的温湿度、洁净度和空气品质问题越来越重视,加上能源的紧缺,节能问题越来越引起人们的重视。因此迫切需要为商业建筑物安装配置节能、健康、舒适的中央空调系统来满足人们对高生活水平的追求。目前,随着我国经济的快速增长,生活条件日益改善,人们对生活环境的舒适性的要求越来越高,对中央空调的需求越来越大,对中央空调节能、舒适、健康更加关注。 国际标准规定,商用空调是3HP以上空调机组的统称,因此商用空调种类颇多。包括风冷热泵型中央空调机组,水冷螺杆式冷水机组、离心式冷水机组等等。 因此,设计一项节能、舒适、健康的中央空调工程是很有实际意义的。 二、研究现状 中央空调在世界上已有百年的发展历史,在中国也有20多年的应用时间,然而真正引起国内企业关注还是近几年。目前国内市场中央空调领域竞争已经进入白热化阶段,随着价格战连绵不断,在家用空调领域几乎已经无利可图的企业纷纷开始在中央空调领域寻找新的发展空间和利润增长点。 2003年中央空调市场容量将达到85亿元,2005年达到200亿元以上。市场空间迅

暖通空调开题报告

河北工程大学 建筑环境与设备工程专业毕业设计开题报告南京市某综合楼空调系统设计 学生姓名:李雪玉 学院:城建学院 专业:建筑环境与设备工程 班级: 11级03班 学号: 110220314 指导教师:张伟捷 2015年5月

1.工程概况 该建筑为南京市某综合办公楼楼,共11层。地下一层,地上十层,地下为停车厂、机房,地上一层为土地办证大厅,空间较大,五层有文体活动室,冷负荷较大,其余各层多为办公室,此综合办公楼建筑面积为17423㎡ , 其中空调面积9112㎡ ,高度46.8m 。该建筑的主要功能为办公用。 2.设计内容 2.1负荷计算 2.1.1 通过外围护结构传热形成的冷负荷 外围护结构冷负荷可按下式计算: )()()(R c c t t AK Q -=? ττ (2-1-1) 式中 K ——屋面或外墙传热系数W/( m 2 ·℃); A ——屋面或外墙面积。 )(τc t ——屋面的逐时冷负荷计算温度,℃; R t ——室内计算温度。 2.1.2外窗日射得热冷负荷 透过外窗的太阳辐射形成的冷负荷,按下式计算: ττn z g c J X AX Q =? )( (2-1-2) 式中 g X ——窗的构造修正系数。 z X ——内遮阳系数。 τn J ——计算时刻下透过有内遮阳设施窗玻璃太阳辐射的冷负荷强度,W/m 2。 2.1.3 外玻璃窗逐时传热形成的冷负荷 外窗传热形成的冷负荷,按下式计算: )()()(R c c t t aAK Q -=? ττ (2-1-3) 式中 a ——窗框修正系数; K ——窗玻璃的传热系数,; )(τc t ——计算时刻下的冷负荷温度。 2.1.4通过内围护结构传热形成的冷负荷

暖通毕业设计文献综述

暖通毕业设计文献综述 【篇一:暖通毕业文献综述】 文献综述 题目家用中央空调的研究与发展前景 学生姓名 专业班级 学号院(系) 指导教师(职称) 完成时间 家用中央空调的研究与发展前景 1 家用中央空调具有的特点 1.1 家用中央空调的优点 (1)具有单台房间空调器的优势。如质量可靠、故障率低、使用灵活、安装方便、维护简单等。 (2)具有中央空调的优势,如房间内温度分布均匀,不占有房间的 使用面积,能和装修较好的配合,室内噪音低等。 (3)具有较好的个性化,~方面要体现在住户个人购买、个人使用,另一方面室内空调机布置能够灵活多样,可根据房间的布局、个人 喜好有多种方案可供选择。 (4)家用中央空调消费群体不光是针对高消费群体,而逐步针对普 通的工薪阶层。随着空调厂家大规模生产、开发,其价格会逐渐回落,使家用中央空调能落户于普通百姓家庭成为可能。 1.2家用中央空调的缺点 (1)比分体空调贵不少,但是配合装修效果非常好。 (2)耗电量比较大,不容易清洗。机组噪音比较大。噪音方面主要 影响的是夜间睡眠,可以调成最低风速运行。另外,在选择中央空 调品牌时可以关注室内机噪音值。 (3)不同品牌价格差距很大,制冷效果也有差距。 2 家用中央空调方式的分析比较 2.1几种家用中央空调输送介质方式的分析比较 中央空调是集中处理空调负荷的系统型式,其冷/热量是通过一定 的介质输送到空调房间里去的。按照家用小型中央空调的输送介质 的不同,常见的家用小型中央空调可以分成以下三种主要型式。 2.1.1风管式系统

风管式系统以空气为输送介质,其原理与大型全空气中央空调系统 的原理基 本相同。它利用室外主机集中产生冷/热量,将从室内引回的回风(或回风和新风的混风)进行冷却/力d热处理后,再送入室内消除其 空调冷/热负荷。相对于其它的家用小型中央空调型式,风管式系 统初投资较小。如若引入新风,其空气品质能得到较大的改善。但 风管式系统的空气输配系统所占用建筑物空间较大,一般要求住宅 要有较大的层高。而且它采用统~送风的方式,在没有变风量末端 的情况下,难以满足不同房间不同的空调负荷要求。而变风量末端 的引入将会使整个空调系统的初投资大大增加。 2.1.2冷/热水机组 冷/热水机组的输送介质通常为水或乙二醇溶液。它通过室外主机 产生出空调冷,热水,由管路系统输送至室内的各末端装置,在末 端装置处冷,热水与室内空气进行热量交换,产生出冷/热风,从 而消除房间空调负荷。它是一种集中产生冷/热量,但分散处理各 房间负荷的空调系统型式。该系统的室内末端装置通常为风机盘管。目前风机盘管一般均可以调节其风机转速(或通过旁通阀调节经过盘 管的水量),从而调节送入室内的冷/热量,因此该系统可以对每个 空调房间进行单独调节,满足各个房间不同的空调需求,同时其节 能性也较好。此外,由于冷/热水机组的输配系统所占空间很小, 因此一般不受住宅层高的限制。但此种系统一般难以引进新风,因 此对于通常密闭的空调房间而言,其舒适性较差。 2.1.3 vrv系统 变制冷剂流量(varied refrigerant volume,简称vrv)空调系统是一 种冷剂式空调系统,它以制冷剂为输送介质,室外主机由室外侧换 热器、压缩机和其他制冷附件组成,末端装置是由直接蒸发式换热 器和风机组成的室内机。一台室外机通过管路能够向若干个室内机 输送制冷剂液体。通过控制压缩机的制冷剂循环量和进入室内各换 热器的制冷剂流量,可以适时地满足室内冷、热负荷要求。vrv系统 具有节能、舒适、运转平稳等诸多优点,而且各房间可独立调节, 能满足不同房间不同空调负荷的需求。但该系统控制复杂,对管材 材质、制造工艺、现场焊接等方面要求非常高,且其初投资比较大。除了风管式系统、冷/热水机组、vrv系统这三种基本的系统型式外,还可以互相交叉,衍生出一些新型的系统。例如,将冷/热水机组 和风管式系统进行组合,往室内送冷热水处理房间空调负

暖通空调毕业设计(论文)任务书解答

毕业设计(论文)任务书 毕业设计(论文)题目:某市某综合楼空调系统设计 系别能源与动力学院班级建环本121/122 学生姓名___________________ 学号 ________________________ 指导教师________ 职称_______________________ 毕业设计(论文)进行地点:校内 _______________________ 任务下达时间:2015 年12 月24 日 起止日期:2016年3月1日起——至2016年6月日止 教研室主任_________________ 年月日批准 1、论文的原始资料及依据:

(一)题目来源:某市某综合楼建筑结构图 (二)设计主要技术参数 (1)土建资料 详见建筑图纸。 (2 )气象参数:根据本市的气象资料确定; (3 )建筑参数: 外墙体结构:根据地区自行选定,如S =370 m m红砖,内外抹灰20mm 屋面:根 据地区自行选定,如200mm 厚混凝土板加12.5mm 厚加气混凝土保温层。 外窗:根据地区自行选定,如标准玻璃的单层钢窗,全部挂淡色窗帘,(4)室内空调设计参数:温度t n=26C; 湿度? n=60% 风速不大于0.3 m/s 。 (5)照明容量:40W/m (6)房间人数:0.5人/m2,群集系数0.92 (三)设计主要技术关键 正确进行空调负荷和新风量的计算,确定出冷气方案,合理地布置管道,并进 行水力计算,合理选择及布置设备,做好气流组织。 2、设计(论文)主要内容及要求通过本次设计使学生系统地掌握空调系统设计的主 要方法和步骤,能根据实际情况合理确定空调方案,会计算空调系统的负荷量和新风负荷量,能合理布置管道和设备,了解空调设备的型式及用途,会进行设备的选型,合理进行气流组织,会计算水管、风道的阻力,选取水泵、风机等。使学生能把所学知识灵活运用到实际当中去,让理论与实际相结合,为学生毕业以后的工作打下坚实基础。 主要内容: 空调系统的设计 1)、由建筑物所在地区确定室内外气象参数; 夏季室内外设计计算参数;室内温度、湿度、风速、新风量等参数。 (2)、空调房间热湿负荷计算;

暖通毕业设计论文

毕业设计说明书 题目:上海市某宾馆中央空调系统设计 (四层夜总会) 所属系、部:建筑工程学院 年级、专业:建筑设备工程技术 101 姓名: x x x 学号: 2010 0809 xxxx 指导教师: x x x 老师 完成时间: 2013年5月

摘要 本工程为上海市某宾馆中央空调系统设计,该建筑是包含办公室、大堂、客房、夜总会、餐厅等于一身的多功能建筑。根据各层建筑的构造及功能,办公楼部分和客房部分选用风机盘管加新风系统,夜总会部分、大堂部分和餐厅部分选用全空气系统。 设计内容:1、空调冷负荷计算2、系统方案确定3、冷源选择4、辅助设备选型5、空调末端处理设备的选型6、风系统设计与计算7、水系统设计,布置及计算 技术参数:1、上海市的气象参数2、设计参数 设计依据:1、技术参数2、相关设计规范手册 关键词:负荷计算;方案选定;设备选型;全空气系统;风系统;水系统;

Abstract This works for a Shanghai hotel central air conditioning system design, the building is office, lobby, guest rooms, nightclubs, restaurants as a multifunctional building.According to each layer architecture and function in the construction of the building parts, lobby and guest room part selects fan-coil unit plus fresh air system, nightclubs and restaurants part selects the all-air system. Design content: 1, the air condition cold load calculation 2, the scheme in the system 3, choice of cold source 4, auxiliary equipment selection 5, air terminal handling equipment selection 6, the wind system design and calculation 7, water system design, layout and calculation technical parameters: 1, the Shanghai meteorological parameters 2, the design parameters Design basis: 1, the technical parameters 2, the related design specifications manual Key words: load calculation; Scheme is selected; Equipment selection; All air system; The wind system; Water system;

办公楼暖通空调系统工程设计_毕业设计说明书

办公楼暖通空调系统工程设计 摘要 本设计为哈尔滨望江集团办公楼空调系统工程设计。哈尔滨望江集团办公楼属中小型办公建筑,本建筑总建筑面积4138m2,空调面积2833m2。地下一层,地上八层,建筑高度33.9m。全楼冷负荷为191千瓦,全楼采用水冷机组进行集中供给空调方式。 此设计中的建筑主要房间为办公室,大多面积较小,且各房间互不连通,应使所选空调系统能够实现对各个房间的独立控制,综合考虑各方面因素,确定选用风机盘管加新风系统。在房间内布置吊顶的风机盘管,采用暗装的形式。将该集中系统设为风机盘管加独立新风系统,新风机组从室外引入新风处理到室内空气焓值,不承担室内负荷。风机盘管承担室内全部冷负荷及部分的新风湿负荷。风机盘管加独立新风系统由百叶风口下送和侧送。水系统采用闭式双管同程式,冷水泵三台,两用一备;冷却水泵选三台,两用一备。 在冷负荷计算的基础上完成主机和风机盘管的选型,并通过风量、水量的计算确定风管路和水管路的规格,并校核最不利环路的阻力和压头用以确定新风机和水泵。 依据相关的空调设计手册所提供的参数,进一步完成新风机组、水泵、热水机组等的选型,从而将其反应在图纸上,最终完成整个空调系统设计。 关键词:风机盘管加独立新风系统;负荷;管路设计;制冷机组:冷水机组

Abstract The design for the Harbin Wangjiang Design Group office building air conditioning system. Harbin Wangjiang Group is a small and medium-sized office building office buildings, the total floor area of building is 4138m2, air-conditioned area is 2833m2. There are eight floor of the building, building height is 33.9m. Cooling load for the entire floor, 191 kilowatts, the whole floor using Central Cooling Chillers to focus on the way . This design of the main room of the building for office, most of them is very small, and the rooms are not connected, the selected air-conditioning system should be able to achieve independent control of each room, considering the various factors to determine the selection of fan-coil plus fresh air system. Arrangement in the room ceiling fan coil units, using the dark form of equipment. Set the focus on fan-coil system, plus an independent air system, fresh air from the outdoor unit to deal with the introduction of a new wind to the indoor air enthalpy value, do not bear the load of indoor. All bear the indoor fan-coil cooling load and part of its new rheumatoid load. Fan-coil plus an independent air system sent by the Venetian and the under side air delivery. Closed water system with a dual-track program, three cold-water pump, dual-use a prepared; cooling pumps three elections, one prepared by dual-use. In the cooling load calculation based on the completion of the selection of host and fan coil units, and air volume, the calculation of water, the wind pipe and water pipes to determine the specifications of the road and check the resistance to the most disadvantaged and the loop to determine the pressure head new fans and pumps. Based on the relevant manuals provided by air-conditioning design parameters, and further completion of the new air units, water pumps, hot water units, such as the selection, which will be reflected in their drawings, the final design of the entire air-conditioning system Key words:PAU+FCU systems; load; pipeline design; refrigeration machine;Chillers

相关主题
文本预览
相关文档 最新文档