摘要

某矿上企业行政办公大楼,总共5层。建筑总高为15.6m,共5层。其中底层层高为3.9m,其余各层层高为3.4m。局部突出屋面的塔楼为楼梯间,高3.0m。

建筑部分:根据建筑的地理位置,所有的功能分区等设计依据进行平面布置、立面、剖面等方面的建筑设计,力求建筑物的实用、经济、美观。

结构部分:结构形式为框架结构,所有的梁、柱及板均采用现浇,基础采用柱下独立基础,绘出结构施工图。

关键词:框架结构现浇

Abstract

Group locates in AnHui Province. It consists of five stories, 15.6m high. The first story is 3.6m high, and the others stories are 3.0m high. In the top story, there is a stairwell 3.0m high.

Architectural part: According to its geography situation and all requisite functions and others conditions, we carry out architecture about the plane layout, vertical plane and vertical sections, etc. At this time, we try our best to make the building beautiful, economical and useful.

Structural part: The structure form is a frame structure, all of the columns, beams, and slabs are cast-in-site. Foundations are independent foundations under columns, and we finish the drawing of the structural design for the next construction at last.

Key word: Frame structure Cast-in-site

第1章建筑设计

建筑设计是在总体规划的前提下,根据任务书的要求综合考虑基地环境,使用功能,结构施工,材料设备,建筑经济及建筑艺术等问题。着重解决建筑物内部各种使用功能和使用空间的合理安排,建筑与周围环境,与各种外部条件的协调配合,内部和外表的艺术效果。各个细部的构造方式等。创造出既符合科学性又具有艺术的生产和生活环境。

建筑设计在整个工程设计中起着主导和先行的作用,除考虑上述各种要求以外,还应考虑建筑与结构,建筑与各种设备等相关技术的综合协调,以及如何以更少的材料,劳动力,投资和时间来实现各种要求,使建筑物做到适用,经济,坚固,美观,这要求建筑师认真学习和贯彻建筑方针政策,正确学习掌握建筑标准,同时要具有广泛的科学技术知识。

建筑设计包括总体设计和个体设计两部分。

1.1 设计任务和主要要求

1.1.1 设计任务

本设计的主要内容是办公楼的设计,办公楼属于行政办公建筑类。作为一个办公空间设计,要在平面规划中自始至终遵循实用、功能需求和人性化管理充分结合的原则。在设计中,既结合办公需求和工作流程,科学合理的划分职能区域,也考虑员工与领导之间、职能区域之间的相互交流。材料运用简洁,大方,耐磨,环保的现代材料,在照明采光上使用全局照明,能满足办公的需要.经过精心设计,在满足各种办公需要的同时,又简洁,大方,美观,能充分体现出企业的形象与现代感.

1.1.2 设计要求

建筑法规、规范和一些相应的建筑标准是对该行业行为和经验的不断总结,具有指导意义,尤其是一些强制性规范和标准,具有法定意义。建筑设计除了应满足相关的建筑标准、规范等要求之外,原则上还应符合以下要求:

(1)满足建筑功能要求:

(2)符合所在地规划发展的要求并具有良好的视觉效果;

(3)采用合理的技术措施;

(4)提供在投资计划所允许的经济范畴内运作的可行性。

1.2.1 气象条件

建设地区的温度、湿度、日照、雨雪、风向、风速等是建筑设计的重要依据,例如:炎热地区的建筑应考虑隔热、通风、遮阳、建筑处理较为开敞;在确定建筑物间距及朝向时,应考虑当地日照情况及主要风向等因素。

1.2.2 地形、地质及地震烈度

基地的地形,地质及地震烈度直接影响到房屋的平面组织结构选型、建筑构造处理及建筑体型设计等。

地震烈度,表示当发生地震时,地面及建筑物遭受破坏的程度。烈度在6度以下时,地震对建筑物影响较小,一般可不做抗震计算,9度以上地区,地震破坏力很大,一般应尺量避免在该地区建筑房屋,建筑物抗震设防的重点时7、8、9度地震烈度的地区。

1.2.3 水文

水文条件是指地下水位的高低及地下水的性质,直接影响到建筑物基础及地下室。一般应根据地下水位的高低及底下水位性质确定是否在该地区建筑房屋或采用相应的防水和防腐措施。

1.3 建筑设计文件的内容及要求

建筑初步设计内容:绘制“3平2立1剖”:“3平”即1个底层平面图,1个楼层平面图,加1个屋顶平面图;“2立”指1个南侧或北侧立面图,加1个东侧或西侧立面图;“1剖”必须剖到楼梯。

建筑设计文件要求:以上图纸均需达到施工图深度,弄清建筑平面、立面和剖面之间的关系,熟悉建筑施工图的表达方式及深度要求,掌握常用的建筑构造措施等。建议用2号图绘制,绘图比例、布局和张数自定,以表达清楚且符合制图习惯为原则。

2.1 设计资料

工程名称:

建设地点:

工程概况:建筑总高为 m,共层。其中底层层高为 m,其余各层层高为 m。局部突出屋面的塔楼为楼梯间,高 m。基本风压:0.50kN/m2

基本雪压:0.40kN/m2

抗震设防烈度:6度,不考虑抗震设防计算。

2.2 结构设计的一般原则

2.2.1 结构设计目的

工程设计是工程建设的首要环节,是整个工程的灵魂。先进合理的设计对于改建、扩建、新建项目缩短工期、节约投资、提高经济效益起着关键作用,使项目达到安全、适用、经济、美观的要求。因而建筑结构设计的基本目的就是要在一定经济条件下赋予结构以适当的可靠度,使结构在预定的基准期内能满足设计所预期的各种功能要求。

2.2.2 结构设计的一般原则

为了达到建筑设计的基本目的,结构设计中应符合以下一般原则:符合设计规范;选择合理的结构设计方案;减轻结构自重;采用先进技术。

2.3 结构选型

2.3.1 结构体系选型

对于一般多层民用建筑,根据使用和工艺要求、材料供应情况和施工技术条件,常选用的结构形式有混合结构、钢筋混凝土框架结构和框架剪力墙结构等结构体系。

由于混合结构整体性差,难于满足大空间的使用要求,而框架剪力墙结构多用于10—25层的高层建筑。而框架结构强度高、结构自重轻,可以承受较大楼面荷载,在水平作用下具有较大的延性。此外框架结构平面布置灵活,能设置大空间,易于满足建筑功能要求。

2.3.2 框架施工方法

钢筋混凝土框架结构按施工方法不同,有现浇式、装配式和整体装配式三种。

现浇式框架的全部构件都在现场整体浇筑,其整体性和抗震性能好,能较好的满足使用要求。

故框架采用现浇施工方法。

2.3.3 其他结构选型

1. 屋面结构:采用现浇钢筋混凝土肋形屋盖,屋面板厚120mm。

2. 露面结构:采用现浇钢筋混凝土肋形楼盖,露面板厚120mm。

3. 楼梯结构:采用钢筋混凝土板式楼梯。

4. 过梁:门窗过梁均采用钢筋混凝土梁,并采用纵向框架兼做窗过梁。

5. 墙基础:因持力层不太深,承载力高,采用自乘墙基大放脚。

6. 基础:因基础持力层不太深,地基承载力高,采用钢筋混凝土柱下独立基础。2.4 框架结构计算简图及构件尺寸

2.4.1 简化假定

建筑物是复杂的空间结构体系,要精确地按照三维空间结构来进行内力和位移分析十分困难。为简化计算,对结构体系引入以下基本假定:

(1).在正常设计、正常施工和正常使用的条件下,结构物在设计基准期内处于弹性工作阶段,其内力和位移均按弹性方法计算;

(2).楼面(或屋面)在自身平面内的刚度无限大,在平面外的刚度很小,可忽略不计。

2.4.2 计算单元

多层框架结构是由纵、横向框架结构组成的空间结构体系,在竖向荷载作用下,各个框架之间的受力影响较小。本设计中取KJ—2作为计算单元,如图2—1所示:

图2—1 结构平面布置图

2.4.3 计算简图

现浇多层框架结构设计计算模型是以梁、柱截面几何轴线来确定,并认为框架柱在基础顶面为固接,框架各节点纵、横向均为刚接。一般情况下,取框架梁、柱截面几何轴线之间的距离作为框架的跨度和柱高度。底层柱高从基础顶面算至二层楼面,基础顶面标高根据地质条件、室内外高差,定为-1.1m,二层楼面标高为 3.6m,故底层柱高为4.7m。其余各层柱高为楼层高3.0m。由此可绘出框架计算简图,如图2—2所示:

图2—2 框架结构计算简图

2.4.4 梁柱截面尺寸及惯性矩

多层框架结构是超静定结构,在计算内力前必须先确定杆件的截面形状、尺寸和

1. 初估构件截面尺寸及线刚度

(1). 梁截面尺寸

边跨 mm l h 500~7506000121~81121~81=???? ??=???? ??=

取h=600mm mm h b 200~30060031~2131~21=???? ??=???? ??=

取b=250mm

则取边跨截面尺寸为:h ?b=250mm ?600mm 中跨 mm l h 200~3002400121~81121~81=???? ??=???? ??=

考虑刚度因素,取mm h 500=

mm h b 167~25050031~2131~21=???? ??=???? ??=

取mm b 250=

则取边跨截面尺寸为:h ?b=250mm ?500mm

(2). 柱截面尺寸

底层柱尺寸 按轴压比要求计算,由公式 :

[][]E s N c N c Fg n N A f f βμμ≥= 式中:

[]N μ——轴压比取1.0;

β——轴压比增大系数,本设计取β=1.0;

F ——柱的荷载面积;

E g ——单位建筑面积上重力荷载值,近似取12-15 kN/m 2;

n ——验算截面以上楼层层数。

对于顶层中柱: 321.08.4 4.214105172699[][] 1.014.3

E s N c N c Fg n N A mm f f βμμ?????≥===? 如取柱截面为正方形,则其边长为416mm 。

根据以上计算结果,并考虑其他因素,本设计中所有柱子截面尺寸都取500mm ?500mm 。

非计算单元的内梁截面尺寸初估方法如上,计算从略。

2. 框架梁、柱线刚度计算

由于现浇楼面可以作为梁的有效翼缘,增大梁的有效刚度,减少框架侧移。考虑这一有利因素,边框架梁取05.1I I =,对中框架梁取00.2I I =。(0I 为梁矩形截面惯性矩) 边跨梁:33

340.250.62.0 2.09.00101212

bh I m -?=?=?=?边

43.010910 4.50106

EI i kN m l ???===? 边 中跨梁:3

3

340.250.52.0 2.0 5.21101212

bh I m -?=?=?=?中 73

43.010 5.2110 6.51102.4

EI i kN m l -???===? 中 柱: 3

3

340.50.5 5.21101212

bh I m -?===? 73

41 3.010 5.2110 3.33104.7

EI i kN m l -???===? 73

425 3.010 5.2110 5.21103.0

EI i kN m l --???===? 相对线刚度:

取25 1.0i -=。则其余各杆件相对线刚度为:

14

'

43.33100.645.2110

i ?==? 4

'46.5110 1.255.2110

i ?==?中 4

'4

4.50100.86

5.2110i ?==?边 框架梁、柱的相对线刚度如图2—3所示,将作为计算节点杆端弯矩分配系数的依据。

图2—3 梁柱相对线刚度图

2.5.1 恒载标准值计算

1. 屋面

防水层(刚性):30mm厚C20细石混凝土防水 1.00kN/m2防水层(柔性):三毡四油铺小石子0.40kN/m2找平层:15mm厚水泥砂浆0.015?20kN/m3=0.30kN/m2找坡层:平均40mm厚水泥焦渣找坡0.040?14kN/m3=0.56kN/m2保温层:60mm厚1:10水泥膨胀珍珠岩0.060?12kN/m3=0.72kN/m2 结构层:120mm厚现浇钢筋混凝土板0.120?25kN/m3=3.00kN/m2抹灰层:10mm厚混合砂浆0.010?17 kN/m3=0.17kN/m2合计 6.15kN/m2 2. 各层楼面(含走廊)

水磨石地面(10mm厚面层,20mm厚水泥砂浆打底)0.65kN/m2 结构层:120mm厚现浇钢筋混凝土板0.120?25kN/m3=3.00kN/m2抹灰层:10mm厚混合砂浆0.010?17kN/m3=0.17kN/m2

合计 3.82kN/m2

3. 梁自重

h?b=300mm?700mm

梁自重:0.3?(0.7-0.12)?25kN/m3=4.35kN/m 抹灰层:10mm厚混合砂浆0.01?(0.7-0.12+0.25/2) ?2?17kN/m3=0.25kN/m

合计 4.60kN/m h?b=250mm?600mm

梁自重:0.25?(0.6-0.12)?25kN/m3=3.00kN/m 抹灰层:10mm厚混合砂浆0.01?(0.6-0.12+0.25/2) ?2?17kN/m3=0.21kN/m

合计 3.21kN/m h?b=250mm?500mm

梁自重:0.25?(0.5-0.12)?25kN/m3=2.38kN/m 抹灰层:10mm厚混合砂浆0.01?(0.5-0.12+0.25/2) ?2?17kN/m3=0.17kN/m

合计 2.55kN/m 4. 柱自重

h?b=500mm?500mm

柱自重:0.5?0.5?25kN/m3=6.25kN/m 抹灰层:10mm厚混合砂浆0.01?(0.5+0.5) ?2?17kN/m3=0.34kN/m 合计 6.59kN/m

标准层

纵墙:[(3.0-0.6)?(8.4-0.5)-1.5?1.5?2] ?0.24?18 kN=62.46kN 铝合金窗(1.5?1.5): 1.5?1.5?2?0.35 kN=1.58kN 贴瓷砖外墙面:[3.0?(8.4-0.5)-1.5?1.5?2] ?0.5 kN=9.60kN 水泥粉刷内墙面:[3.0?(8.4-0.5)-1.5?1.5?2] ?0.36 kN=6.91kN

合计80.55kN 底层

纵墙:[(4.7-0.6)?(8.4-0.5)-1.5?1.5?2] ?0.24?18 kN=120.48kN 铝合金窗(1.5?1.5): 1.5?1.5?2?0.35 kN=1.58kN

贴瓷砖外墙面:[3.6?(8.4-0.5)-1.5?1.5?2] ?0.5 kN=11.97kN 水泥粉刷内墙面:[3.6?(8.4-0.5)-1.5?1.5?2] ?0.36 kN=8.62kN

合计142.65kN 6. 内纵墙自重

标准层

纵墙:[(3.0-0.6)?(8.4-0.5)-0.9?2.1?2] ?0.24?18 kN=123.60kN 门(h?b=0.9?2.1):0.9?2.1?2?0.15 kN=0.57kN 粉刷墙面:[(3.0-0.6)?(8.4-0.5)-0.9?2.1?2] ?0.36?2 kN=10.93kN 合计78.08kN/m

底层

纵墙:[(4.7-0.6)?(8.4-0.5)-0.9?2.1?2] ?0.24?18 kN=123.60kN 门(h?b=0.9?2.1):0.9?2.1?2?0.15 kN=0.57kN 粉刷墙面:[(3.6-0.6)?(8.4-0.5)-0.9?2.1?2] ?0.36?2 kN=14. 34kN 合计138.51kN/m 7. 内隔墙自重

标准层

墙重:(3.0-0.6)?(6.0-0.5)?0.24?18 kN=57.02kN 粉刷墙面:(3.0-0.6)?(6.0-0.5) ?0.36?2 kN=9.05kN

合计66.07kN

底层

墙重:(4.7-0.6)?(6.0-0.5)?0.24?18 kN=97.42kN 粉刷墙面:(3.6-0.6)?(6.0-0.5) ?0.36?2 kN=11.88kN 合计109.30kN

2.5.2 活荷载标准值计算

1. 屋面和楼面活荷载标准值

上人屋面:2.0kN/m2

2.雪荷载:

基本雪压:0.45kN/m 2

雪荷载标准值:0 1.00.450.45k r s u s kN ==?=

屋面活荷载和雪荷载不同时考虑,二者中取大值。

2.5.3 竖向荷载下框架受荷总图

1. B —C,D —E 轴间框架梁

屋面板传荷载:

板传至梁上的三角形或梯形荷载为均布荷载,荷载的传递示意图,如图2—4所示:

图2—4 荷载传递示意图

恒载:

236.15 2.1(120.350.35)220.61/kN m ??-?+?= 活载:

232.0 2.1(120.350.35)2 6.70/kN m ??-?+?= 楼面板传荷载:

荷载传递示意图如图2——4所示

恒载:

233.82 2.1(120.350.35)212.80/kN m ??-?+?= 活载:

232.0 2.1(120.350.35)2 6.70/kN m ??-?+?=

梁自重: 3.21/kN m

2.B —C,D —E 轴间框架梁均布荷载为:

屋面梁:恒载=梁自重+板传荷载

=

活载=板传荷载

=6.70/kN m

楼面梁:恒载=梁自重+板传荷载

=3.21/12.80/16.01/kN m kN m kN m +=

活载=板传荷载

=6.70/kN m

C ——

D 轴间框架梁均布荷载为:

梁自重: 2.55/kN m

屋面梁:恒载=梁自重

=2.55/kN m

活载=0

楼面梁:恒载=梁自重

=2.55/kN m

活载=0

3. B 、E 轴柱纵向集中荷载的计算

顶层柱:

女儿墙自重(做法:墙高1100mm ,混凝土压顶100mm )

330.24 1.118/0.240.125/(1.220.24) 6.67/m m kN m m m kN m m m kN m ??+??+?+= 天沟自重:

现浇,如图2——5所示

3225/[0.6(0.20.08)]0.08(0.60.2)0.5/ 1.84/kN m m m m m m kN m kN m ?+-?++?= 顶层柱恒载=女儿墙及天沟自重+纵梁自重+板传荷载

(6.67 1.84)8.4 4.60(8.40.5) 2.5560.5

10.3060.58.078.4214.16kN

=+?+?-+??+??+?=

顶层柱活载=板传荷载

=3.3560.5 2.638.432.14kN ??+?=

标准层柱恒载=外纵墙自重+纵梁自重+板传荷载+横隔墙 80.55 4.60(8.40.5)8.9560.5

5.018.46

6.52219.08kN

=+?-+??+?+=

顶层柱活载=板传荷载

=3.3560.5 2.638.432.14kN ??+?=

4. C 、D 轴柱纵向集中荷载的计算

4.60(8.40.5)12.8560.5

6.15 1.28.48.078.4204.67kN =?-+??+??+?=

顶层柱活载=板传荷载

=3.3560.5 2.638.4 2.0 1.28.450.30kN ??+?+??=

标准层柱恒载=内纵墙自重+纵梁自重+板传荷载+横隔墙

78.08 4.60(8.40.5)8.9560.5

5.018.4 3.82 1.28.4255.12kN =+?-+??+?+??=

顶层柱活载=板传荷载

=3.3560.5 2.638.4 2.5 1.28.457.34kN ??+?+??=

由上可作出框架在竖向荷载作用下的受荷总图,如图2——6所示:

图2——6 竖向荷载作用下受荷总图

2.5.4 竖向荷载下框架受荷总图

作用在屋面梁和搂面梁节点处的集中风荷载标准值:

0()/2k z s z i j W u u h h B βω=+

为了简化计算,通常将计算单元范围内外墙面的分布荷载化为等量的作用于楼面的集中风荷载。

式中:基本风压200.35/w kN m =

z u ——风压高度变化系数。因建设地点处于大城市郊区,地面粗糙程度为B 类;

s ——风荷载体型系数,查表取s =1.3;

z β——风振系数。由于结构高度小于30m ,且高宽比18.4/14.4=1.26<1.5,则

取z β=1.0;

i h ——下层柱高;

j h ——上层柱高,顶层取女儿墙高度的两倍;

B ——计算单元迎风面宽度(B=8.4m )

计算过程见表2——1

2.5.5 竖向荷载下框架受荷总图

1. 侧移刚度

见表2——2和表2——3

2. 风荷载下框架位移计算

水平荷载作用下框架的层间侧移可按下式计算:

j j ij V u D ?=∑

式中:

j V ——第j 层的剪力;

ij D ∑——第j 层所有柱的抗侧刚度之和;

j u ?——第j 层的层间位移。

第一层的层间位移值求出以后,就可以计算各楼板标高处的侧移值的顶点侧移值,各层楼板标高处的侧移值应该是该层以下各层层间侧移之和,顶点侧移是所有各层层间侧移之和。

j 层侧移 1

j j j

j u u ==?∑

顶点侧移 1n j

j u u ==?∑

框架在风荷载下侧移的计算见表2——4,如下:

层间最大侧移值为: 1/3060<1/550,满足要求

顶点侧移 10.00241j

j j j u u m ==?=∑

且 u/H=1/7510<1/650,满足要求

2.6 荷载计算

为简化计算,考虑如下几种单独受荷情况:

(2) 活载分跨布置作用(分左布活载、中布活载、右布活载)

(3) 风荷载作用(分左风和右风)

对于第(1)种情况,采用分层法计算;第(2)种情况利用PF 程序计算;第(3)情况,采用D 值法计算。

2.6.1 恒载作用下的内力计算

在竖向荷载作用下框架内力采用分层法进行简化计算,此时每层框架梁同上、下层柱组成基本计算单元。竖向荷载产生的梁端弯矩只在本层内进行弯矩分配,单位之间不再进行传递。

计算步骤如下:

(1) 根据各杆件的线刚度计算各节点杆端弯矩分配;

(2) 计算竖向荷载作用下各跨梁的固端弯矩,并将各节点不平衡弯矩进行第一次分

配;

(3) 将所有杆端的分配弯矩向远端传递;

(4) 将个节点因传递弯矩而产生的不平衡弯矩进行第二次分配,使得各节点处于平

衡状态;

(5) 将各杆件的固端弯矩,分配弯矩和传递弯矩相加即可得各杆端弯矩。

1. 计算分配系数

说明:计算时除底层柱以外,其它各层柱的线刚度先乘以0.9,取传递系数为1/3(梁和底层柱的传递系数为1/2)。 分配系数按以下式计算:

1ik

ik n ik i S u S ==∑

式中: ik S 为节点k第i根杆件的相对转动刚度;

1n ik

i S =∑为节点k各杆件相对转动刚度之和。

由于本榀框架结构、受力对称,在分层法计算时可取半结构进行计算。

2. 梁的固端弯矩

均布恒载和柱顶集中活载偏心引起的固端弯矩构成节点不平衡弯矩,利用以下公式计算: 2

12

ql M =

可求得各梁端弯矩,如表2——5和表2——6

3. 固端弯矩第一次分配

计算过程见图2——7(括号中为不平衡弯矩)

(a)顶层

(b)中间层

(c)底层

图2——7恒载作用下分层法计算

将图2——7中(a)、(b)、(c)结果叠加组合后得到框架弯矩图2——8,可以看出节点存在不平衡弯矩。

图2——8恒载作用下弯矩一次分配图4. 节点不平衡弯矩二次分配

计算过程见图2——9所示:

(顶层)

结构毕业设计计算书

目录 第一部分设计原始资料 0 第二部分结构构件选型 0 一、梁柱截面的确定 0 二、横向框架的布置 (1) 三、横向框架的跨度和柱高 (2) 第三部分横向框架内力计算 (2) 一、风荷载作用下的横向框架(KJ-14)内力计算 (2) 三、竖向恒载作用下的横向框架(KJ-14)内力计算 (10) 四、竖向活载作用下的横向框架(KJ-14)内力计算 (21) 第四部分梁、柱的内力组合 (28) 一、梁的内力组合 (28) 二、柱的内力组合 (30) 第五部分梁、柱的截面设计 (34) 一、梁的配筋计算 (34) 二、柱的配筋计算 (35) 第六部分楼板计算 (38) 第七部分楼梯设计 (40) 第一节楼梯斜板设计 (40) 第二节平台板设计 (41) 第三节楼梯梁设计 (41) 第八部分基础设计 (43) 第一节地基承载力设计值和基础材料 (43) 第二节独立基础计算 (43) 参考文献 (48) 致谢 (49)

第一部分 设计原始资料 建筑设计图纸:共三套建筑图分别为:某办公楼全套建筑图:某五层框架结构。 1.规模:所选结构据为框架结构,建筑设计工作已完成。总楼层为地上3~5层。各层的层高及各层的建筑面积、门窗标高详见建筑施工图。 2.防火要求:建筑物属二级防火标准。 3.结构形式:钢筋混凝土框架结构。填充墙厚度详分组名单。 4.气象、水文、地质资料: (1)主导风向:夏季东南风、冬秋季西北风。基本风压值W 0详分组名单。 (2)建筑物地处某市中心,不考虑雪荷载和灰荷载作用。 (3)自然地面-10m 以下可见地下水。 (4)地质资料:地质持力层为粘土,孔隙比为e=0.8,液性指数I 1=0.90,场地覆盖层为1.0 M ,场地土壤属Ⅱ类场地土。地基承载力详表一。 (5)抗震设防:该建筑物为一般建筑物,建设位置位于6度设防区,按构造进行抗震设防。 (6)建筑设计图纸附后,要求在已完成的建筑设计基础上进行结构设计。 第二部分 结构构件选型 一、梁柱截面的确定 1、横向框架梁 (1)、截面高度h 框架梁的高度可按照高跨比来确定,即梁高h=)8 1 ~121(L 。 h=)81~121( L 1=)8 1 ~121(×9200=767~1150mm 取h=750mm (2)、截面宽度 b=)2 1~3 1(h=)2 1~3 1(×750=250~375mm 取b=250mm 2、纵向连系梁 (1)、截面高度 h=11( ~)1218L 1=11 (~)1218×3600=300~200mm 取h=300mm (2)、截面宽度

【6层】6000平米框架结构办公楼毕业设计板计算书

办公楼设计计算书 设计简介: 拟建建筑多层办公楼为永久性建筑,能满足350左右的人工作,该建筑所在地使用面积(红线面积)2 72151080m ?=位于攀枝花市区,建筑周围配有休闲广场,绿化带。 办公楼实际占地面积69.6114.4L B ?=?=,分为六层。总建筑面积为2 6000m , 采用现浇楼板,现浇框架纵横向承重,各层层高均3.3m ,在设计计算时考虑抗震设防要求。 各层楼的布局中有普通办公室、专用办公室、会议室、接待室、陈列室、卫生间和 开水房等满足使用要求。 第一部分 双向板的设计 板采用现浇整体式楼板,板厚100h mm =,采用25C 混凝土,板中钢筋采用235HPB 级钢筋,在该多层办公楼设计中,除中间两跨为单向板外其余楼板均为双向板。采用弹性理论计算的方法来计算板和支座中的内力,采用弯矩调幅法对结构按弹性理论方法所求的弯矩值和剪力值进行适当的调整,以考虑结构非弹性变形所引起的内力重分布。 一.梁的截面尺寸和板的计算跨度及荷载确定 拟定板厚100h mm =,板的保护层厚度20mm , 则板的有效高度为01002080h mm =-=。纵横向主次梁确定: 主梁高1111 ( )()(60008400)5001050128128h l mm ==?=,取700h mm =, 1111( )()7003502332323b h mm ==?=,取300b mm =。 次梁高1 111( )()60005003331281218h l mm ==?=,取500h mm =, 1111( )()500250166.72 323 b h mm ==?=,取250b mm =。 所以主梁截面尺寸为300700b h mm mm ?=?, 次梁截面尺寸为250500b h mm mm ?=?。 二.板荷载的确定 (一)荷载设计值 1.楼面的做法如图所示:

某高校教学楼计算书毕业设计_说明

华中科技大学土木工程2001级毕业设计 ——某高校教学楼 计算书 (下册) 设计: 指导教师 华中科技大学土木工程与力学学院

4 第⑨轴横向框架力组合及配筋计算 (86) 4.1 力组合....................................... 错误!未定义书签。 4.2 截面设计 (91) 5 部分板设计 (153) 5.1 七层板设计................................... 错误!未定义书签。 5.2 底层板设计................................... 错误!未定义书签。 6 1号楼梯设计 (160) 6.1 梯段板设计 (160) 6.2 平台板设计 (161) 6.3 平台梁设计 (162) 6.4 构造措施 (164) 7 主楼电算 (164) 7.1 PKPM电算 .................................... 错误!未定义书签。 7.2 电算、手算结果比较与分析..................... 错误!未定义书签。 7.3 基础设计荷载................................. 错误!未定义书签。 7.4 BIS隔震设计分析 ............................. 错误!未定义书签。 8 部分基础设计 (164) 8.1 基础隔震设计................................. 错误!未定义书签。 8.2 条形基础设计 (165) 9 全文总结 (176) 10 致 (178) 11 参考文献 (179)

毕业设计结构计算书(格式模板)

湖南科技大学 毕业设计(论文) 题目 作者 学院 专业 学号 指导教师 二〇〇年月日

湖南科技大学 毕业设计(论文)任务书 院系(教研室) 系(教研室)主任:(签名)年月日 学生姓名: 学号: 专业: 1 设计(论文)题目及专题: 2 学生设计(论文)时间:自年月日开始至年月日止 3 设计(论文)所用资源和参考资料: 4 设计(论文)应完成的主要内容: 5 提交设计(论文)形式(设计说明与图纸或论文等)及要求: 6 发题时间:年月日 指导教师:(签名) 学生:(签名)

湖南科技大学 毕业设计(论文)指导人评语 [主要对学生毕业设计(论文)的工作态度,研究内容与方法,工作量,文献应用,创新性,实用性,科学性,文本(图纸)规范程度,存在的不足等进行综合评价] 指导人:(签名) 年月日指导人评定成绩:

湖南科技大学 毕业设计(论文)评阅人评语 [主要对学生毕业设计(论文)的文本格式、图纸规范程度,工作量,研究内容与方法,实用性与科学性,结论和存在的不足等进行综合评价] 评阅人:(签名) 年月日评阅人评定成绩:

湖南科技大学 毕业设计(论文)答辩记录 日期: 学生:学号:班级: 题目: 提交毕业设计(论文)答辩委员会下列材料: 1 设计(论文)说明书共页 2 设计(论文)图纸共页 3 指导人、评阅人评语共页 毕业设计(论文)答辩委员会评语: [主要对学生毕业设计(论文)的研究思路,设计(论文)质量,文本图纸规范程度和对设计(论文)的介绍,回答问题情况等进行综合评价] 答辩委员会主任:(签名) 委员:(签名) (签名) (签名) (签名)答辩成绩: 总评成绩:

混凝土结构设计毕业设计计算书

混凝土结构设计毕业设 计计算书 This model paper was revised by LINDA on December 15, 2012.

本科毕业设计 河南省郑州市企业办公楼的设计 学院:城市建设学院 专业:土木工程 学号:1162 学生姓名:郑健 指导教师:唐红 日期:二○一七年六月 摘要 本设计的题目是:河南省郑州市企业办公楼的设计,结构建筑规模为6层框架结构,各层层高(底层层高),建筑物总高度为 ,总建筑面积为。 对本课题的研究将分为毕业实习、建筑设计、结构设计、毕业设计整理四个方面。毕业实习阶段,收集必要的设计原始资料,做好设计前的调查研究工作,参考同类型设计的文字及图纸资料。学习有关的国家法规及规范。建筑设计分为初步设计及施工图设计两个阶段,在此阶段将拟定建筑方案,确定建筑使用的材料及做法,确定建筑的总体形状及各种尺寸,绘出平、立、剖、总平面图、详图、写出施工说明并列出门窗明细表。结构设计

阶段主要是进行结构计算简图的确定、荷载计算、内力分析、内力组合、梁、柱截面配筋、板的设计、楼梯的设计、基础的设计以及结构施工图的绘制等;毕业设计整理阶段则是对毕业设计所需资料的装订,按学校毕业设计条例及教研室实施细则整理毕业设计成果,做好毕业答辩准备工作。 关键词:结构设计;框架结构;荷载;配筋

Abstract This design topic is the design of Zhengzhou city enterprise office building, construction scale of 6 storey frame structure, each layer of (bottom height , the building’s height is , and the total construction area are . The study on this subject will be divided into graduation practice, architectural design, structural design, from four aspects of the design of finishing. The graduation practice stage, collecting the original design information necessary to do research work, before the design, drawings and documents with reference to the text type design. Learn about the national regulations and architectural design specifications. The design of the two stages of preliminary design and construction drawing, this stage will draw the construction plan, determine the use of materials and construction practices, to determine the overall shape and size, building paint Ping, Li, section, general layout, construction details, write instructions and lists the windows list. The structure design stage is mainly determined. The structure calculation diagram load calculation, internal force analysis, the combination of internal forces, beam, column reinforcement, plate design, stair design, foundation design and construction drawing design; finishing The stage is the information needed in the graduation design of binding rules for the

高层办公楼-框架结构毕业设计计算书

摘要 本设计为高层综合办公楼,其现实意义和迫切性不言而喻。该设计结合现代的办公观念,突出“以人为核心”的设计理论,采用大面积自主布置、两端部设置交通核、环形布置房间等设计手法,在外观上将主体分为三大部分,努力创造高耸的视觉效果。本结构采用使用部分的大空间布置,具有平面灵活,使用性强,安全合理等特点。在满足近期使用功能的同时兼顾今后的改建,从结构上做到为用户创造方便舒适优美的办公休息空间。在总平面的布置中采用主体建筑位于中心,四周布置娱乐休闲设施的方式,并保证了交通的合理性与防火要求。 高层建筑已经成为当今不可回避的生存方式之一,这是城市人口聚集的必然趋势,所以做好高层设计的意义重大。 关键词高层办公楼框架结构 word文档可自由复制编辑

Abstract This graduation design is a high-rise office building, the realism meaning and the imminency are self-evident. This design is combined with the concept of modern official business work,giving prominence to the theory of “all for user”. It adopt the technique of large-area independence disposal、central communication、annular dispose room and so on.In the appearance,the principal part contains three parts, trying to create towering vision impression.This structure adopts the picket-foundation.Thus it has the advantages such as agility plane 、better using capability、safe and logical etc. It can fulfil the using function in the near future, at the same time, it gives attention to rebuild in the future, consequently it provides the consumers a convenient 、comfort and concinnity space. In the disposal of total plane, we adopt the fashion that the main construction lies in the centre with the entertainment establishment in the around, and it can also guarantee the rationality of traffic and the require of fireproofing. High-rise building has become one of the survival manners that can’t be evasive nowadays. This is the trend of population-assemble in the city, so it’s significant to design the high-rise building well. Keywords high-rise office building picket-foundation word文档可自由复制编辑

四层办公楼教学楼宿舍楼毕业设计

办公楼、教学楼、宿舍楼、旅馆毕业设计 一、设计资料: 建设地点:南方某城市。 场地面积:长×宽=110×70m,建筑平面设计可不考虑场地周边影响。 总建筑面积:3000±10%平方米。 最高气温:41℃。 最低气温:-8℃。 主导风向:夏季东南风,冬季西北风。 基本风压:0.35KN/m2。 基本雪压:0.5 KN/m2。 最大降雨量:60mm/h。 场地地震效应:建筑物所在地区抗震设防烈度为6度,设计基本地震加速度为0.05m/ s2,设计地震分组为第一组,拟建场地土类型中软场地土,Ⅱ类建筑场地。 地质水文情况:场地平坦,周围无相邻建筑物。自上而下土层分布情况为: 1、填土(Qm l),褐黄色,松散,湿,以粘性土为主,局部含快石和植物根系,层厚1m,不宜作为拟建建筑物的基础持力层。 2、粉质黏土(Qa l+p l), 褐黄色,可塑,湿,含褐色铁锰氧化物结核,层厚1m,f ak=200kPa,E S =7.7Mpa。 3、粉质黏土(Qa l+p l), 褐黄色,硬塑,湿,含褐色铁锰氧化物结核,该层未穿透,f ak=200kPa, E S=7.7Mpa。场地土15m深度X围内无液化土层。 二、建筑设计功能要求: 设计题目(一):某办公楼设计 (一)、层数为不超过4层,净高为3.6米。 (二)、建筑主要组成用房: 门厅:80平方米×1 传达值班:36平方米×1 展览室(含储藏室):120平方米×1(可与门厅结合布置) 接待室:30平方米×2 保健室:20平方米×2 办公室:20平方米×40(可考虑部分为大开间办公室) 套间办公室(带接待室):40平方米×5 小会议室:40平方米×2

某淀粉厂废水处理毕业设计-说明书计算书

某淀粉厂废水处理毕业设计-说明书计算书

一、前言 (一)设计任务来源 学院下达设计任务。 (二)原始资料 原始资料见设计任务书。 (三)设计要求 设计要求按扩大初步设计要求完成设计文件。 (四)设计指导思想 毕业设计的目的是使学生综合运用所学的理论知识,根据“环境保护法”和设计规范以及党和政府颁布的各项政策和法令,依据原始资料,设计一座城市或工业企业的污水处理厂,具体指导思想如下: 1.总结、巩固所学知识,通过具体设计,扩大和深化专业知识,提高解决实际工程技术问题的独立工作能力; 2.熟悉建造一座现代化污水处理厂的设计程序,掌握各类处理构筑物的工艺计算,培养分析问题的能力; 3.广泛阅读各类参考文献及科技资料,正确使用设计规范,熟练应用各种设计手册,标准设计图集以及产品目录等高等工具书,进一步提高计算、绘图的技能和编写好设计说明书,完成工程师的基本训练。 (五)设计原则 “技术先进、经济合理、安全使用、确保质量”。 二、概述 淀粉属多羟基天然高分子化合物,广泛地存在于植物的根、茎和果实中。淀粉是食物的重要成分,是食品、化工、造纸、纺织等工业部门的主要原料。 目前,我国淀粉行业有600多家企业,其中年产万吨以上的淀粉企业仅60多家。该行业1979—1992年的13年中,年产量从28万t增加到149万t,平均年递增率14%。1998年淀粉产量为300多万t。每生产13 m废水,在淀粉、酒 m淀粉就要产生10—203

精、味精、柠檬酸等几个较大的生物化工行业中,淀粉废水的总排放量占首位。淀粉废水中的主要成分为淀粉、蛋白质和糖类,随生产工艺的不同,废水中的Cr COD 浓度在2 000—20 000mg/L 之间。这些淀粉废水若不经处理直接排放,其中所含的有机物进入水体后会迅速消耗水中的溶解氧,造成水体因缺氧而影响鱼类和其他水生生物的生存,同时还会促使水底的有机物质在厌氧条件下分解而产生臭味,恶化水体,污染环境,损害人体健康。因此废水必须进行处理。 淀粉生产的主要原料作物有甘薯类、玉米和小麦。 (一)以甘薯类为原料的淀粉生产工艺是根据淀粉不溶于冷水和其密度大于水的性质,采用专用机械设备,将淀粉从水中的悬浮液中分离出来,从而达到生产淀粉的目的。作为原料的马铃薯等都是通过流水输送到生产线的,在流送过程中,马铃薯等同时得到了一定程度的洗净。除此之外,淀粉厂内还设有专门清除马铃薯等表皮所沾染的污物和砂土的洗净工序。这两工段(洗净和流送工段)流出的废水含有大量的砂土、马铃薯碎皮碎片以及由原料溶出的有机物质。因而这种废水悬浮物含量多,Cr COD 和5BOD 值都不高。 原料马铃薯经洗净后,磨碎形成淀粉乳液。乳液中含有大量的渣滓,需使淀粉乳与渣滓分离,淀粉乳进入精制、浓缩工段。这时,分离废水中含有大量的水溶性物质,如糖、蛋白质、树脂等,此外还含有少量的微细纤维和淀粉。Cr COD 和5BOD 值很高,并且水量较大,因而这一工段是马铃薯原料淀粉厂主要污染废水。 在精制淀粉乳脱水工序产生的废水水质与分离废水相同。 淀粉生产过程中,产生大量渣滓,长期积存在贮槽内,会产生一定量酸度较高的废水。另外,还有蛋白分离废水、生产设备洗刷废水、厂区生活废水等。 (二)以玉米为原料的生产工艺其废水主要来源于浸泡、胚芽分离、纤维洗涤和脱水等工序。此工艺主要表现为耗水量大和淀粉提取率低,这就造成了玉米淀粉废水量大,且污染物浓度高。工艺用水量一般为5—123m /t 玉米。玉米淀粉废水中的主要成分为淀粉、糖类、蛋白质、纤维素等有机物质,Cr COD 值为8 000—30 000mg/L ,5BOD 值为5 000—20 000mg/L ,SS 值为3 000—5 000mg/L 。 (三)以小麦为原料的生产工艺其废水由两部分组成:沉降池里的上清液和离心后产生的黄浆水。前者的有机物含量较低,后者的含量较高。生产中,通常将两部分的废水混合后称为淀粉废水。

钢框架结构计算书-毕业设计

摘要 该计算书为滨岛医疗中心门诊楼建筑方案及钢框架结构设计计算书,本设计依据建筑方案及给出的结构类型。参照规范有《建筑结构荷载规范》(GB 50009-2012)、《建筑抗震规范》(GB 50011-2010)、《混凝土结构规范》(GB 50010-2010)、《钢结构设计规范》(GB 50017-2003)等。完成设计内容有:建筑方案、结构平面布置、结构计算简图确定、荷载统计、内力计算、内力组合、主、次梁、柱选取及布置连接截面验算以及节点设计、楼梯设计、基础设计、工程概预算。结构类型为钢框架结构,梁、柱为钢梁、钢柱,板为组合楼板,柱脚采用埋入式,楼梯为板式钢筋混凝土楼梯、基础采用锥形独立基础。本计算书中列出了框架在恒荷载、活荷载、地震荷载、风荷载作用下的弯矩、剪力、轴力图以及内力组合表。 关键词结构设计;钢框架;独立基础;医用建筑

Abstract The calculations for the BinDao medical center clinic building steel frame building solutions and design calculations, based on the design and construction program structure given type. Design process based on structural loads standard (GB50009-2012) determine the structure of the load, in accordance with the Seismic Design of Buildings (GB50011-2010), design of steel structures (GB50017-2003) and the relevant requirements for structural design and calculation. The main work to complete the structure diagram layout and calculation of the identification, load statistics, internal force calculation and combination of primary and secondary beams and floor cross-section design and checking, node connection design, staircase design, basic design as well as project budget.Type of structure is steel frame structure, beams, columns of steel beams, steel columns, plates of composite slabs, column foot buried, reinforced concrete slab staircase stairs, independent foundation with a tapered base. Meanwhile, The calculations in the framework of the book lists the dead load, live load, seismic loads, wind loads bending moment, shear, axial force, and force combination table. Keywords Structural Design; Steel Frame;single footing medical building;

框架结构办公楼荷载计算书非常详细.doc

某办公楼工程荷载计算书 一、楼面荷载 楼面恒载 办公室、接待室、会议室、走廊、展厅、仓储用房、配电间、照明控制、智能化控制机房:130 厚面层(地暖) 2.5 吊顶或底粉0.4 恒载: 2.9 kN/m 2 卫生间 3.0 楼面活载 办公室、接待室、会议室: 2.0 走廊:2.5 展厅:3.5 仓储用房、配电间、照明控制: 5 智能化控制机房:7 公共卫生间: 4.0,其他卫生间、清扫间: 2.5 不上人屋面 块瓦型钢板彩瓦0.13kN/ m 2 冷弯型钢挂瓦条0.5kN/ m 2 2 100 厚保温层(水泥珍珠岩)4*0.1=0.4kN/m 2 1.5mm 厚防水层0.1 kN/ m 15 厚1:3 水泥砂浆找平层20*0.015=0.3 kN/m 2 底粉或吊顶0.4 kN/ m 2 恒载: 1.83kN/ m 2*cos22=1.96 kN/ m 2 活载:0.5kN/ m 2 二、墙荷载 非承重空心砖内墙 240 厚非承重空心砖墙体12.5*0.24=3.0 kN/m 2 2 40 厚粉刷20*0.04=0.8 kN/m 合计: 3.8 kN/m 2 承重多孔砖外墙(包石材) 240 厚承重多孔砖墙体15.5*0.24=3.72 kN/m 2 外挂石材 1 kN/m2 内墙20 厚粉刷20*0.02=0.4 kN/m 2 合计: 5.12 kN/m 2 多孔砖内墙(卫生间) 2 240 厚承重多孔砖墙体15.5*0.24=3.72 kN/m

内墙40 厚粉刷20*0.04=0.8 kN/m 2 合计: 4.52 kN/m 2 多孔砖内墙(楼梯间、展厅) 2 240 厚承重多孔砖墙体15.5*0.24=3.72 kN/m 干挂石材 1.0 kN/m 2 面砖20*0.04=0.8 kN/m 2 合计: 5.32 kN/m 2 120 多孔砖墙 120 厚多孔砖墙15.5*0.12=1.96kN/m 2内墙40 厚粉刷20*0.04=0.8 kN/m 2合计: 2.66 kN/m 2 通高窗 1.0 kN/m 2,洞窗0.5 kN/m 2 外墙外挂石材 1.0 kN/m 2 门0.5 kN/m 2 1、二~三层墙荷载 700 高框梁下空心砖内墙 3.8 * (3.9-0.7)= 12.2 kN/m 750 高框梁下空心砖内墙 3.8 * (3.9-0.75)= 12.0 kN/m 600 高次梁下空心砖内墙 3.8 * (3.9-0.6)= 12.6 kN/m 650 高次梁下空心砖内墙 3.8 * (3.9-0.65)= 12.4 kN/m 950 高次梁下空心砖内墙 3.8 * (3.9-0.95)= 11.2 kN/m 120 板下空心砖内墙 3.8 *(3.9-0.12)= 14.4 kN/m 700 高框梁下承重多孔砖内墙 4.52 * (3.9-0.7)= 14.5 kN/m 750 高框梁下承重多孔砖内墙 4.52 * (3.9-0.75)= 14.3 kN/m 600 高次梁下承重多孔砖内墙 4.52 * (3.9-0.6)= 15.0 kN/m 400 高梁下120 多孔砖墙 2.66* (3.9-0.4)= 9.3 kN/m 通高承重多孔砖外墙 5.12*3.9=20 kN/m 通高窗1*3.9=3.9 kN/m B 轴外墙(3*20+4.2*3.9 )/7.2=10.6 kN/m A 轴外墙(7.12*20+5.88*3.9 )/13=12.7 kN/m E 轴外墙(4.6*20+8.4*3.9 )/13=9.6 kN/m 1 轴外墙(10.96*20+3*3.9 )/13.96=16.6 kN/m 1 轴悬挑板自重及板面荷载: 120 厚板25*0.12*0.82=2.46 kN/m 板面恒载+活载(3.0+2.0)*0.82=4.1kN/m 合计: 6.56 kN/m

毕业设计教学楼计算书1

3.5.1 柱截面尺寸的确定 柱截面高度可以取,H为层高;柱截面宽度可以取为。选定柱截面尺寸为500 mm×500mm 3.5.2 梁尺寸确定 框架梁截面高度取梁跨度的l/8~l/12。该工程框架为纵横向承重,根据梁跨度可初步确定框架梁300mm×600mm 3.5.3 楼板厚度 楼板为现浇双向板,根据经验板厚取130mm。 3.6 基本假定与计算简图 3.6.1 基本假定 第一:平面结构假定:该工程平面为正交布置,可认为每一方向的水平力只由该方向的抗侧力结构承担,垂直于该方向的抗侧力结构不受力。 第二:由于结构体型规整,布置对称均匀,结构在水平荷载作用下不计扭转影响。 3.6.2 计算简图 在横向水平力作用下,连梁梁对墙产生约束弯矩,因此将结构简化为刚结计算体系,计算简图如后面所述。 3.7荷载计算 作用在框架结构上的荷载通常为恒载和活载。恒载包括结构自重、结构表面的粉灰重、土压力、预加应力等。活荷载包括楼面和屋面活荷载、风荷载、雪荷载、安装荷载等。 高层建筑水平力是起控制作用的荷载,包括地震作用和风力。地震作用计算方法按《建筑结构抗震设计规范》进行,对

高度不超过40m以剪切为主且质量和刚度沿高度分布比较均匀的结构,可采用底部剪力法。 竖向荷载主要是结构自重(恒载)和使用荷载(活载)。结构自重可由构件截面尺寸直接计算,建筑材料单位体积重量按荷载规范取值。使用荷载(活荷载)按荷载规范取值,楼面活荷载折减系数按荷载规范取用。 3.8 侧移计算及控制 框架结构的侧移由梁柱杆件弯曲变形和柱的轴向变形产生的。在层数不多的框架中,柱轴向变形引起的侧移很小,可以忽略不计。在近似计算中,一般只需计算由杆件弯曲引起的变形。 当一般装修标准时,框架结构在地震作用下层间位移和层高之比、顶点位移与总高之比分别为1:650,1:700。 框架结构在正常使用条件下的变形验算要求各层的层间侧移值与该层的层高之比不宜超过1/550的限值。 3.9 内力计算及组合 3.9.1 竖向荷载下的内力计算 竖向荷载下内力计算首先根据楼盖的结构平面布置,将竖向荷载传递给每榀框架。框架结构在竖向荷载下的内力计算采用分层法计算各敞口单元的内力,然后在将各敞口单元的内力进行叠加;连梁考虑塑性内力重分布而进行调幅,按两端固定进行计算。 3.9.2 水平荷载下的计算 利用D值法计算出框架在水平荷载作用下的层间水平力,

土木工程毕业设计范文,图纸计算书、建筑说明书外文翻译、开题报告书

- - -. 毕业设计(论文) 开题报告 题目XX雅筑地产中天锦庭6号住宅楼设计 专业土木工程 班级 学生 指导教师教授 讲师

一、毕业设计(论文)课题来源、类型 本论文课题来源于XX雅筑地产中天锦庭6号住宅楼设计,本设计来自工程实际,结构类型为钢筋混凝土剪力墙结构。该建筑分十三层,耐火等级为一级,主体结构为二级耐久年限,抗震设防为八级。二、选题的目的及意义 随着我国经济发展和城市化进程,人们对住宅的需求量逐渐增多,住宅物业管理日益为人们所关注。住宅小区已经成为人们安家置业的首选,几十万到几百万的小区住宅比比皆是。尤其近几年,高层小高层已然成为现代开发商与消费者选择的主流。这是由高层和小高层的特点所决定的,高层建筑可节约城市用地,缩短公用设施和市政管网的开发周期。人们花的钱越多,不但对住宅的本身的美观质量要求越来越高,同时对物业小区的服务和管理也要求越来越高,比如对小区的绿化,保安,停车场,维修甚至对各项投诉的要求小区管理者做的好。信息时代的今天,住宅小区的硬件设施也必须跟得上时代的步伐,对现代化住宅小区建设的要求越来越高。小区楼的艺术美更要符合现代人的需求,此外还必须有较高的实用性、经济性。住宅小区的居住环境安全与否,是小区居民极其关心的问题,要创建一个安全的居住环境不仅要有科学的小区管理制度,而且在很大程度上也依赖于小区规划的安全性,这其中涉及到居民的生理、心理安全和社会安全等因素。在住宅小区的规划设计中应充分考虑居民的有效防X行为,通过控制小区和组团入口、明确划分空间领域等措施来提高小区的安全防卫能力。一是在小区和组团的入口处设置明显标志,使住宅小区具有较强的领域性和归属性。二是注重院落空间的强化,使居民之间既有充分了解和相互熟悉的机会,又可以使住户视线能够触及到住宅入口,便于对陌生人进行观察、监视。三是注重小区交通网络的合理组织。在小区主干道的规划设计上要做到“顺而不穿,通而不畅”,减少交通环境的混乱交杂,提高安全系数,在小区级道路的规划上尽量作曲形设计,限制车辆穿行的速度,达到安全与降低噪音的目的。同时,规划时应尽量减少组团的出入口,一般设置两个即可,以便有效控制外来行人任意穿行,从而起到安全防卫的作用。我这次选择的是高层住宅楼的设计,目的就是为了设计一栋满足居住需求和美观要求的住宅楼。并且也可以通过这次的毕业设计,把以前学习的专业课的知识运用到实践中,以及对它们更加深入的学习和系统化的总结。在这个过程中需要查阅、搜集许多的资料,将提高我运用图书馆的资料文献和互联网上大量信息的能力。office办公软件的综合运用使我的电脑基本功有了很大的提高。从建筑设计到结构的计算设计都是由自己单独完成,这就培养了我们独立解决设计中的问题以及娴熟使用auto CAD和PKPM系列软件的能力。综合性地运用几年内所学知识去分析、解决一个问题,在作毕业设计的过程中,所学知识得到疏理和运用,它既是一次检阅,又是一次锻炼。

框架结构中学教学楼毕业设计计算书

框架结构中学教学楼毕业设计计算书 篇一:土木工程毕业设计五层教学楼框架结构计算书安徽建筑大学 摘要 本工程是费县晨光高中教学楼,为多层钢筋混凝土框架结构,共五层,层高为3.6米,建筑物总高度为19.100米。在遵循“适用、安全、经济、美观”的设计原则和国家有关现行建筑结构设计规范与标准的基础上,进行了教学楼的建筑与结构初步设计,获得了该建筑物初步设计阶段的建筑CAD设计图纸与技术指标,确定了结构布置方案与结构计算模型。 先进行了层间荷载代表值的计算,然后按底部剪力法计算水平地震荷载作用下大小,进而求出在水平荷载作用下的结构内力(弯矩、剪力、轴力)。接着计算竖向荷载(恒载、活荷载以及雪荷载)作用下的结构内力,找出最不利的一组或几组内力组合。选取最安全的结果计算配筋并绘图。此外还进行了结构方案中的室内楼梯的设计(完成了平台板,梯段板,平台梁等构件的内力和配筋计算)、楼盖的设计(完成了板的配筋和梁的配筋)、基础的设计(完成了基础的配筋) 关键词:钢筋混凝土,框架,结构设计 安徽建筑大学

Abstract This is a teaching building of a Chenguang chool in Feixian. It is a multi-layer reinforced concrete frame. It has five stories, the height of the storey is 3.6 meters.The height of the whole building is 18.75 meters. In accordance with the design principle of “applicability、safety、economy、aesthetic”and the present codes and standards of the architectural and structural design, the primary architectural and structural design of building is carried out. After getting the architectural drawing from CAD design, the anthor decides the structural scheme and the structural calculation model of the bottom-shear force method. The seismic force can be assigned according to the shearing stiffness of the frames of the different axis. Then the internal force in the structure under the horizontal loads can be easily calculated. After the determination of the internal force under the dead and live loads, the xxbination of internal force can be made by using the Excel software, whose purpose is to find one or several sets of the most adverse internal force of the wall limbs and the coterminous girders, which will be

毕业设计计算书教材

1.工程概况与设计资料 1.1结构形式 采用二层钢筋混凝土框架结构。 1.2水文地质 地基土层自上而下为:人工填土,层厚0.6~1.0m;褐黄色粘土,层厚4.0~4.5m,f a k= 80 kN / m2,γ = 19 kN / m3;灰色淤泥质粉土,层厚20~22m,f ak= 70 kN / m2,γ = 18kN / m3;暗绿色粉质粘土,未穿,f ak= 160 kN / m2,γ = 20 kN / m3。 地下水位在自然地表以下0.8m,水质对结构无侵蚀作用。 基础持力层为褐黄色粘土层。 1.3设计荷载 基本风压及基本雪压按上海地区采用。 常用建筑材料和构件自重参照荷载规范确定。 屋面使用荷载按上人屋面设计;楼面使用荷载值根据荷载规范确定。 抗震设防烈度为7度。 1.4楼屋面做法 屋面:防水层(防水卷材八层做法,三毡四油上铺小石子,0.35 kN / m2),40厚C20细石混凝土找平层(双向配筋φ4 @200),保温层(膨胀水泥珍珠岩,平均高度h = 100mm, 4 kN / m3),油膏胶泥一度隔气层,现浇钢筋混凝土屋面板,板下20厚纸筋灰粉底。 楼面:30厚水泥砂浆找平,现浇钢筋混凝土板,板下20厚纸筋灰粉底。 1.5材料 混凝土:基础用C20;上部结构用C25。 墙体:±0.000以下采用MU10标准砖,M5水泥砂浆;±0.000以上采用MU10多孔砖,M5混合砂浆。 1.6建筑平面尺寸、使用荷载 平面尺寸:纵向跨数×纵向跨度(m)—横向跨数×横向跨度(m)= 7×5.7m—2×6.3m 楼面活荷载:4.4 kN / m2 屋面活荷载:2.0 kN / m2 1.7主要参考资料 <<建筑结构荷载规范>> GB5009-2001 <<混凝土及砌体结构>>教材 <<混凝土结构设计规范>> GB50010-2002 <<混凝土结构设计>>教材 <<建筑抗震设计规范>> GB50011-2001 <<结构力学>>教材 <<建筑地基基础设计规范>> GB50007-2002 <<房屋建筑学>>教材 29

毕业设计框架结构设计计算书

结构设计计算书 一.设计概况 1.建设项目名称:星海国际花园住宅楼(B 栋) 2.建设地点:深圳市某地 3.设计资料: 3.1.地质水文资料:根据工程地质勘测报告,拟建场地地势平坦,表面为平均厚度0.5m 左右的杂填土,以下为1.0m 左右的淤泥质粘土,承载力的特征值为80 kN/m 2 ,再下面为较厚的 垂直及水平分布比较均匀的粉质粘土层,其承载力的特征值为180kN/m 2 ,可作为天然地基持力层。 地下水位距地表最低为-0.8m,对建筑物基础无影响。 3.2.气象资料: 全年主导风向:偏南风 夏季主导风向:东南风 冬季主导风向:北偏西风 常年降雨量为:1283.70mm 基本风压为:0.36kN/m 2 (B 类场地) 基本雪压为:0.20kN/m 2 3.3.抗震设防要求:七度二级设防 3.4.底层室内主要地坪标高为±0.000,相当于绝对标高31.45m 。 二.结构计算书 1.结构布置方案及结构选型 1.1.结构承重方案选择 根据建筑功能要求以及建筑施工的布置图,本工程确定采用框架承重方案,框架梁、柱布置参见结构平面图。 1.2.主要构件选型及尺寸初步估算 1.2.1. 主要构件选型 (1)梁﹑板﹑柱结构形式:现浇钢筋混凝土结构 (2)墙体采用:粉煤灰轻质砌块 (3)墙体厚度:外墙:250mm ,内墙:200mm (4)基础采用:柱下独立基础 1.2.2. 梁﹑柱截面尺寸估算 (1) 主要承重框架: 因为梁的跨度较接近(4500mm ﹑4200mm ),可取跨度较大者进行计算. 取L=4500mm h=(1/8~1/12)L=562.5mm~375mm 取h=450mm. 447.94504260>==h l n ==h b )31~21(225mm~150mm 取b=250mm 满足b>200mm 且b 500/2=250mm 故主要框架梁初选截面尺寸为:b ×h=250mm ×450mm (2) 次要承重框架: 取L=3900mm h=(1/12~1/15)L=325mm~260mm 取h=400mm 415.74003660>==h l n ==h b )3 1~21(200mm~133mm 取b=250mm 故次要框架梁初选截面尺寸为:b ×h=250mm ×400mm (3)楼面连续梁