----- 钢柱设计信息-----

钢材等级:235

柱高(m):15.000

柱截面:空心圆管截面:

D*T=1000*12

柱平面内计算长度系数:1.000

柱平面外计算长度:0.000

强度计算净截面系数:1.000

截面塑性发展:考虑

构件所属结构类别:独立柱

设计内力:

绕X轴弯矩设计值Mx (kN.m):1600.000

绕Y轴弯矩设计值My (kN.m):0.000

轴力设计值N (kN):180.000

----- 设计依据-----

《钢结构设计规范》(GB 50017-2003)

----- 柱构件设计-----

1、截面特性计算

A =4.9461e-002; Xc =5.0000e-001; Yc =5.0000e-001;

Ix =5.9895e-003; Iy =5.9895e-003;

ix =3.4799e-001; iy =3.4799e-001;

W1x=1.1979e-002; W2x=1.1979e-002;

W1y=1.1979e-002; W2y=1.1979e-002;

2、柱构件强度验算结果

截面塑性发展系数: γx=1.150

柱构件强度计算最大应力(N/mm2): 119.784 < f=215.000

柱构件强度验算满足。

3、柱构件平面内稳定验算结果

平面内计算长度(m):15.000

平面内长细比λx:43.105

对x轴截面分类:b 类

轴心受压稳定系数φx:0.886

等效弯矩系数βmx:1.000

计算参数Nex'(KN):49201.949

柱平面内长细比:λx=43.105 < [λ]= 150.000

柱构件平面内稳定计算最大应力(N/mm2): 120.593 < f=215.000 柱构件平面内验算满足。

4、柱构件平面外稳定验算结果

平面外计算长度(m):0.000

平面外长细比λy:0.000

对y轴截面分类:b 类

轴心受压稳定系数φy:1.000

受弯整体稳定系数φbx:1.000

等效弯矩系数βtx:1.000

闭口截面影响系数:η=0.7

柱平面外长细比:λy=0.000 < [λ]= 150.000

柱构件平面外稳定计算最大应力(N/mm2): 97.136 < f=215.000 柱构件平面外验算满足。

5、局部稳定验算

外径与壁厚之比D/T=62.50 < 容许外径与壁厚之比[D/T]=100.0

****** 柱构件验算满足。******

-------------------------------

| GL4 梁构件设计|

----- 设计信息-----

钢材等级:235

梁跨度(m):2.000

梁截面:[ 形截面:

H*B1*B2*Tw*T1*T2=120*60*60*5*5*5

梁平面外计算长度:2.000

强度计算净截面系数:1.000

截面塑性发展:考虑

构件所属结构类别:单层工业厂房

----- 设计信息-----

设计内力是否地震作用组合:否

梁上荷载作用方式:均布荷载

梁上荷载作用位置:上翼缘

设计内力:

绕X轴弯矩设计值Mx (kN.m):8.000

绕Y轴弯矩设计值My (kN.m):0.000

剪力设计值V (kN):8.000

----- 设计依据-----

《钢结构设计规范》(GB 50017-2003)

----- 梁构件设计-----

1、截面特性计算

A =1.1500e-003; Xc =1.6848e-002; Yc =6.0000e-002;

Ix =2.5396e-006; Iy =3.9816e-007;

ix =4.6993e-002; iy =1.8607e-002;

W1x=4.2326e-005; W2x=4.2326e-005;

W1y=2.3633e-005; W2y=9.2268e-006;

2、梁构件强度验算结果

截面塑性发展系数: γx=1.050

梁构件强度计算最大应力(N/mm2): 180.007 < f=215.000

梁构件强度验算满足。

3、梁构件整体稳定验算结果

平面外计算长度(m):2.000

平面外长细比λy:107

注意:规范没有规定该类截面的整体稳定系数计算方法,整体稳定没有进行验算!

4、梁构件抗剪验算结果

计算点(形心点)以上对中和轴面积矩(m3):Sx =3.6000e-005

梁构件计算最大剪应力(N/mm2): 22.681 < fv=125.000

梁构件抗剪验算满足。

梁构件设计

| 280x140工字钢梁构件设计|

----- 设计信息-----

钢材等级:235

梁跨度(m):9.000

梁截面:焊接组合H形截面:

H*B1*B2*Tw*T1*T2=300*250*250*6*12*12

梁平面外计算长度:1.000

强度计算净截面系数:1.000

截面塑性发展:考虑

腹板屈曲后强度:不考虑

构件所属结构类别:单层工业厂房

----- 设计信息-----

设计内力是否地震作用组合:否

梁上荷载作用方式:无荷载作用

设计内力:

绕X轴弯矩设计值Mx (kN.m):20.000

绕Y轴弯矩设计值My (kN.m):1.000

剪力设计值V (kN):20.000

----- 设计依据-----

《钢结构设计规范》(GB 50017-2003)

----- 梁构件设计-----

1、截面特性计算

A =7.6560e-003; Xc =1.2500e-001; Yc =1.5000e-001;

Ix =1.3500e-004; Iy =3.1255e-005;

ix =1.3279e-001; iy =6.3894e-002;

W1x=9.0000e-004; W2x=9.0000e-004;

W1y=2.5004e-004; W2y=2.5004e-004;

2、梁构件强度验算结果

截面塑性发展系数: γx=1.050

截面塑性发展系数: γy=1.200

梁构件强度计算最大应力(N/mm2): 24.497 < f=215.000

梁构件强度验算满足。

3、梁构件整体稳定验算结果

平面外计算长度(m):1.000

平面外长细比λy:16

受弯整体稳定系数φb:1.000

梁构件整体稳定计算最大应力(N/mm2): 25.555 < f=215.000

梁构件整体稳定验算满足。

4、梁构件抗剪验算结果

计算点(形心点)以上对中和轴面积矩(m3):Sx =4.8913e-004

梁构件计算最大剪应力(N/mm2): 12.077 < fv=125.000

梁构件抗剪验算满足。

5、梁构件折算应力验算结果

计算点(翼缘与腹板交点)以上对中和轴面积矩(m3):Sx2 =4.3200e-004

梁构件计算最大折算应力(N/mm2): 27.555 < 1.1f=236.500

梁构件折算应力验算满足。

6、局部稳定验算

翼缘宽厚比B/T=10.17 < 钢结构规范GB50017容许宽厚比[B/T] =13.0 腹板计算高厚比H0/Tw=46.00 < 钢结构规范GB50017容许高厚比[H0/Tw]=80.0

****** 梁构件验算满足。******

----- 设计信息-----

钢材等级:235

梁跨度(m):9.000

梁截面:国标宽、窄翼缘H型钢:HW250X250

梁平面外计算长度:1.000

强度计算净截面系数:1.000

截面塑性发展:考虑

构件所属结构类别:单层工业厂房

----- 设计信息-----

设计内力是否地震作用组合:否

梁上荷载作用方式:无荷载作用

设计内力:

绕X轴弯矩设计值Mx (kN.m):20.000

绕Y轴弯矩设计值My (kN.m):1.000

剪力设计值V (kN):20.000

----- 设计依据-----

《钢结构设计规范》(GB 50017-2003)

----- 250x250H型钢梁构件设计-----

1、截面特性计算

A =9.1430e-003; Xc =1.2500e-001; Yc =1.2500e-001;

Ix =1.0689e-004; Iy =3.6480e-005;

ix =1.0810e-001; iy =6.3200e-002;

W1x=8.5500e-004; W2x=8.5500e-004;

W1y=2.9200e-004; W2y=2.9200e-004;

2、梁构件强度验算结果

截面塑性发展系数: γx=1.050

截面塑性发展系数: γy=1.200

梁构件强度计算最大应力(N/mm2): 25.132 < f=215.000

梁构件强度验算满足。

3、梁构件整体稳定验算结果

平面外计算长度(m):1.000

平面外长细比λy:16

受弯整体稳定系数φb:1.000

梁构件整体稳定计算最大应力(N/mm2): 26.246 < f=215.000

梁构件整体稳定验算满足。

4、梁构件抗剪验算结果

计算点(形心点)以上对中和轴面积矩(m3):Sx =4.7630e-004

梁构件计算最大剪应力(N/mm2): 9.902 < fv=125.000

梁构件抗剪验算满足。

5、梁构件折算应力验算结果

计算点(翼缘与腹板交点)以上对中和轴面积矩(m3):Sx2 =4.1300e-004

梁构件计算最大折算应力(N/mm2): 25.544 < 1.1f=236.500

梁构件折算应力验算满足。

6、局部稳定验算

翼缘宽厚比B/T=7.68 < 钢结构规范GB50017容许宽厚比[B/T] =13.0

腹板计算高厚比H0/Tw=21.78 < 钢结构规范GB50017容许高厚比[H0/Tw]=80.0 ****** 梁构件验算满足。******

钢结构设计计算书

《钢结构课程设计任务书》 一、设计题目:焊接普通钢屋架设计 二、普通钢屋架课程设计目的及要求 通过钢屋架课程设计要求能掌握屋盖系统结构布置和进行构件编号的方法;能综合运用有关力学和钢结构课程所学知识,对钢屋架进行内力分析、截面设计和节点设计;掌握钢屋架施工图的绘制方法。 三、课程设计资料 1. 建筑类别 厂房总长度120m,檐口高度15m。厂房为单层单跨结构,内设两台中级工作制桥式吊车。 拟设计钢屋架简支与钢筋混凝土柱上,混凝土强度等级为C30。柱顶截面尺寸为400?400mm。钢屋架设计不考虑抗震设防。 厂房柱距选择: 6米 2. 屋架形式 2.1 三角形屋架 1)属有檩体系:檩条采用槽钢10,跨度为6m,跨中设一根拉条φ10。 2)屋架屋面做法及荷载取值(标准荷载值) 永久荷载:波形石棉瓦自重 0.20kN/m2 檩条及拉条自重 0.20kN/m2 保温木丝板重 2 2 2 2 2 d4cm 0.25kN/m e4cm 0.38kN/m f8cm 0.50kN/m 10cm 0.60kN/m h12cm 0.70kN/m ? ? ? ? ? ? ? ?? :厚 :厚 :厚 g:厚 :厚 钢屋架及支撑重(0.12+0.011?跨度)kN/m2 可变荷载:屋面活荷载 0.30kN/m2 积灰荷载 10.2 20.3 30.35 40.4 --- ? ?--- ? ? --- ? ?--- ? kN/m2 注: 1.以上荷载值均为水平投影 2.A,B屋架的形式与尺寸见图1

2.2 梯形钢屋架 1)属无檩体系:采用预应力混凝土大型屋面板(1.5m ?6m)。 2)屋架屋面做法及荷载取值(标准荷载值) 永久荷载:防水层(三毡四油上铺小石子) 0.35kN/m 2 找平层(2cm 厚水泥砂浆)0.02?20=0.4kN/m 2 保温层(泡沫混凝土):222d 4cm 0.25kN/m e 8cm 0.50kN/m f 12cm 0.70kN/m ?? ??? :厚:厚:厚 预应力大型屋面板: 1.4kN/m 2 钢屋架及支撑重: (0.12+0.011?跨度)kN/m 2 可变荷载:屋面活荷载 0.70kN/m 2 积灰荷载 ??? ? ??? ------------6.045.034.023.01kN/m 2 注:1.以上数值均为水平投影值 2.C 形式及尺寸见图1

多高层钢结构住宅楼毕业设计计算书

多 高 层 钢 结 构 住 宅 方案设计

1、工程概况 1.1工程名称:雅居乐多高层钢结构住宅; 1.2建设地点:东莞市区某地; 1.3工程概况:场地大小为30m×30m,8~12层,建筑总高度不超过40m,室内外高差为0.3m,设计使用年限为50年; 1.4基本风压:0ω=0.8kN/m2,地面粗糙程度为C类; 1.5抗震要求:抗震设防类别为丙类,抗震设防烈度为8度,Ⅱ类场地土,设计地震分组为第一组。 2、场地土层情况 表2-1 场地土层情况 3 3.1建筑布置 3.1.1首层建筑平面图 如下图3-1所示,首层平面设计为大空间的形式,可以用此空间做为店面,即商住两用住宅。中间设计为过道、楼梯和电梯。由过道和墙把首层建筑分开为四个大空间,作为四爿店。由于商业的要求,首层平面将进行比较豪华的装修,例如钢柱将外包为方柱,而墙也做成玻璃幕墙与装饰墙混合的形式。此外,门也将用比较好看的旋转门,以吸引顾客。

图 3-1 首层建筑平面图 3.1.2标准层平面图 如下图3-2所示,标准层平面设计为商品房,以中间两墙为分隔墙,分为四户。朝北两户面积较小,内设一个客厅,四个卧室,两个卫生间,一个厨房,一个阳台(左右侧阳台以一墙分开)。而朝南两户面积较大,内设一个客厅,五个卧室,一个书房,一个厨房,两个卫生间,一个杂物间,一个独立阳台。此外,左右两户为于中间墙对称。

图 3-2 标准层平面图 3.1.3顶层平面图 如下图3-3所示,顶层设计为空旷的天台,外围有1.2m的女儿墙,屋檐外挑500mm。

图3-3 顶层平面图

3.1.4剖面图 图3-4 剖面图1

钢结构梯形屋架课程设计计算书(绝对完整)

第一章:设计资料 某单跨单层厂房,跨度L=24m,长度54m,柱距6m,厂房内无吊车、无振动设备,屋架铰接于混凝土柱上,屋面采用1.5*6.0m太空轻质大型屋面板。钢材采用Q235-BF,焊条采用E43型,手工焊。柱网布置如图2.1所示,杆件容许长度比:屋架压杆【λ】=150 屋架拉杆【λ】=350。 第二章:结构形式与布置 2.1 柱网布置 图2.1 柱网布置图 2.2屋架形式及几何尺寸 由于采用大型屋面板和油毡防水屋面,故选用平坡梯形钢屋架,未考虑起拱时的上弦坡度i=1/10。屋架跨度l=24m,每端支座缩进0.15m,计算跨度l0=l-2*0.15m=23.7m;端部高度取H0=2m,中部高度H =3.2m;起拱按f=l0/500,取50mm,起拱后的上弦坡度为1/9.6。 配合大型屋面板尺寸(1.5*6m),采用钢屋架间距B=6m,上弦节间尺寸1.5m。选用屋架的杆件布置和尺寸如施工图所示。

图2.2 屋架的杆件尺寸 2.3支撑布置 由于房屋较短,仅在房屋两端5.5m开间内布置上、下弦横向水平支撑以及两端和中央垂直支撑,不设纵向水平支撑。中间各屋架用系杆联系,上下弦各在两端和中央设3道系杆,其中上弦屋脊处与下弦支座共三道为刚性系杆。所有屋架采用统一规格,但因支撑孔和支撑连接板的不同分为三个编号:中部6榀为WJ1a ,设6道系杆的连接板,端部第2榀为WJ1b,需另加横向水平支撑的的连接螺栓孔和支撑横杆连接板;端部榀(共两榀)为WJ1c。 图2.3 上弦平面

12 1 2 1---1 2---2 图2.3下弦平面与剖面 第三章:荷载计算及杆件内力计算 3.1屋架荷载计算 表3.1 屋架荷载计算表 3.2屋架杆件内力系数 屋架上弦左半跨单位节点荷载作用下的杆件内力系数经计算如图所示。屋架上弦左半跨单位节点荷载、右半跨单位节点荷载、全跨单位节点荷载作用下的屋架左半跨杆件的内力

户外广告牌设计计算书

作品名称: 参赛队员: 专业名称: 土木工程学院

目录 第1部分设计说明书 (2) 1.1设计思路 (2) 1.2 特色说明 (2) 第2部分设计方案图 (4) 2.1 结构总装配图 (5) 2.2构件详图 (5) 第3部分设计计算书 (7) 3.1 计算模型 (7) 3.2 结构计算假定及材料特性 (8) 3.2.1 计算假定 (8) 3.2.2构件截面尺寸 (8) 3.2.3材料力学性能 (8) 3.3结构动力分析 (8) 3.3.1计算模型建模 (8) 3.3.2计算过程 (9) 3.3.3计算结论 (10)

第1部分设计说明书 1.1、设计思路 户外广告牌种类包括:地铁广告、公交车广告、机场广告、火车站广告、射灯广告牌、单立柱广告牌、大型灯箱、候车亭广告牌等。 广告牌在公共类的交通、运输、安全、福利、储蓄、保险、纳税等方面;在商业类的产品、企业、旅游、服务等方面;在文教内的文化、教育、艺术等方面,均能广泛地发挥作用。 高速公路沿线广告牌设计主要由基础设计及上部结构设计两部分,主要考虑自身结构安全以及风荷载对其的影响,同时考虑广告牌架体的防腐耐久性能、满足地基承载力的设计条件要求等系列问题。 1.2特色说明 本模型设计的特色有以下五个方面: (1)构件加固设计加工精细合理构件加固设计采用长和宽为1.5cm×1cm的肋片在柱子薄弱环节里面加固,表面采用砂纸打磨,光滑质轻,在较小增加模型质量的基础上起到了很好的加固作用,同时使得柱子形状精细别致。 (2)空间框架结构体系简明采用空间框架结构体系,结构布置简明,荷载传递路径清晰,各杆件受力合理,充分利用了木材的力学性能。 (3)棱台形式对称美观采用棱台形式,结构形式对称美观,使斜柱的布置方向与其受力方向接近一致,有效地减小了构件上所受的弯矩及侧向变形,更好地满足了结构的抗剪要求,另外,使结构在X、

钢结构设计计算书

《钢结构设计原理》课程设计 计算书 专业:土木工程 姓名 学号: 指导老师:

目录 设计资料和结构布置- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1 1.铺板设计 1.1初选铺板截面 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 1.2板的加劲肋设计- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 1.3荷载计算 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 3.次梁设计 3.1计算简图- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 3.2初选次梁截面 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 3.3内力计算 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 3.4截面设计 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 4.主梁设计 4.1计算简图 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 4.2初选主梁截面尺寸 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 5.主梁内力计算 5.1荷载计算- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 5.2截面设计- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 6.主梁稳定计算 6.1内力设计- - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - 11 6.2挠度验算- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13 6.3翼缘与腹板的连接- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13 7主梁加劲肋计算 7.1支撑加劲肋的稳定计算 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14 7.2连接螺栓计算 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14 7.3加劲肋与主梁角焊缝 - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - 15 7.4连接板的厚度 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15 7.5次梁腹板的净截面验算 - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15 8.钢柱设计 8.1截面尺寸初选 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16 8.2整体稳定计算 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16 8.3局部稳定计算 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17 8.4刚度计算 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17 8.5主梁与柱的链接节点- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 18 9.柱脚设计 9.1底板面积 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 21 9.2底板厚度 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 21 9.3螺栓直径 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 21 10.楼梯设计 10.1楼梯布置 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22

单层双跨重型钢结构厂房设计计算书

一.建筑设计说明 一、工程概况 1.工程名称:青岛市某重型工业厂房; 2.工程总面积:3344㎡ 3.结构形式:钢结构排架 二、建筑功能及特点 1.该拟建的建筑位于青岛市室内,设计内容:重型钢结构厂房,此建筑占 地面积3344㎡。 2.平面设计 建筑物朝向为南北向,双跨厂房,每跨跨度为21m,柱距为6m,采用柱网为21m ×6m,纵向定位轴线采用封闭式结合方式。 3.立面设计 该建筑立面为了满足采光和美观需求,设置了大面积的玻璃窗。 4.剖面设计 吊车梁轨顶标高为 6.9m,柱子高度H=6.9+3.336+0.3=10.536,取柱子高度为10.8m。 5.防火 防火等级为二级丁类,设一个防火分区,安全疏散距离满足房门只外部出口或封闭式楼梯间最大距离。 室内消火栓设在两侧纵墙处,两侧及中间各设两个消火栓,满足间距小于50m 的要求。 6.抗震 建筑的平面布置规则,建筑的质量分布和刚度变化均匀,满足抗震要求。 7.屋面 屋面形式为坡屋顶:坡屋顶排水坡度为10%,排水方式为有组织内排水。屋面做法采用《01J925-1压型钢板、夹芯板屋面及墙体建筑构造》中夹芯钢板屋面。 8.采光 采光等级为Ⅳ级,窗地比为1/6,窗户面积为1160㎡,地面面积为3344平方米,窗地比满足要求,不需开设天窗。 9.排水 排水形式为有组织内排水,排水管数目为21个。 三、设计资料 1.自然条件 2.1工程地质条件:场区地质简单,无不利工程地质现象,条件良好, 地基承载力标准值1000Kpa,为强风化花岗岩,场区内无地下水。 冻土深度为0.5m。 2.2抗震设防:6度 2.3防火等级:二级 2.4建筑物类型:丙类 2.5基本风压:W=0.6KN/㎡,主导风向:东南风

钢结构厂房设计计算书

毕业设计说明书(毕业论文) 毕业设计(论文)题目 专业:土木工程专业 学生:赵鹏 指导教师:王羡农 河北工程大学土木工程学院 2013年05月29日

摘要 本设计工程为邯郸地区一67.5米双跨钢结构。主要依据《钢结构设计规范})GB50017-2003和《门式刚架轻型房屋钢结构技术规程》GECS 102:2002等国家规范,综合考虑设计工程的规模、跨度、高度及用途,依据“适用、经济、在可能条件下注意美观”的原则,对各组成部分的选型、选材、连接和经济性作了比较,最终选用单层门式钢架的结构形式。梁、柱节点为刚性连接的门式钢架具有结构简洁、刚度良好、受力合理、使用空间大及施工方便等特点,便于工业化,商品化的制品生产,与轻型维护材料相配套的轻型钢结构框架体系己广泛应用于建筑结构中,本设计就是对轻型钢结构的实际工程进行建筑、结构设计与计算。主要对承重结构进行了内力分析和内力组合,在此基础上确定梁柱截面,对梁柱作了弯剪压计算,验算其平而内外的稳定性;梁柱均采用Q235钢,10. 9级摩擦型高强螺栓连接,局部焊接采用E43型焊条,柱脚刚性连接,梁与柱节点也刚性连接;屋面和墙面维护采用双层彩色聚苯乙烯夹芯板;另外特别注重了支撑设置、拉条设置,避免了一些常见的拉条设计错误。 关键词:轻型钢结构门式钢架内力分析双层彩色聚苯乙烯夹芯板节点

Abstract This project in handan area is a 67.5m double-span steel structure. The project designed strictly complies with the relavant stipulations of the "CODE FOR DESIGN OF STEEL STRUCTURES (GF50017-2003)" and "TECHNICAL SPECIFICATION FOR STEEL STRUCTURE OF LIGHT WEIGHT BUILDINGS WITH GABLED FRAMES (CECS 102:2002)", and some others. Synthesize the scale of the consideration design engineering and across a principle for span and use, according as" applying, economy, under the possible term attention beautifully", Connecting method, structure type and material of each part which consist of a light-weight steel villa are analysed, then choose the construction form that use single layer a type steel. The beam, pillar node is a light steel construction frame system that rigid and copular a type steel a ware for having construction Simple, just degree goodly, suffering dint reasonablely, using space bigly and starting construction convenience etc. characteristics, and easy to industrialisation, commercializing produce, thinking with light maintenance material the kit the already extensive applying in the building construction inside, this design is to proceeds the building, construction design to the structural and actual engineering in light steel and calculation. The tractate includes the internal force analyzes and combines, based on these analyses; we can choose the section of beam and calumniation. Next, checking computatians of stability calculatian of the plane structure. The steel beam and column employs Q235 carbon structural steel. Connection bolts are high strength bolt of friction type with behavioral grade 10.9. Common bolts are rough type made by Q235-B.F steel. Rod for manual welding usually adopts E43..Rigid connections apply to the column leg and the connection of column and beam adopts hinged connection. The metope and roofage adopts the Bauble-decked colored polystyrene clamps the circuit board. otherwise, it is analysed that the forced state of the bracing system for a steel factor building under wind land, and the design of a bracing truss for a building with larger width. Avoid some errors in the design of brace, tension rod, and tension rod jpints. Keywords:Lightweight steel structures; gabled frame; the internal force analyzes; The double-decked colored polystyrene clamps the circuit board;joint

钢结构屋架设计计算书

. 1.设计资料 某车间厂房总长度约为108米,跨度为18m。车间设有两台30吨中级工作制吊车。车间无腐蚀性的介质。该车间为单跨双坡封闭式厂房,屋架采用三角形豪式钢屋架。屋面坡度为1:3,屋架间距为6m,屋架下弦标高为9米,其两端铰支于钢筋 混凝土柱上,上柱截面尺寸为400mm×400mm,混泥土强度等级为C20。屋面采用彩色压型钢屋板加保温层屋面,C型檩条,檩距为1.5~2?。屋面的活荷载为kNm=1.0,屋面的恒荷载的标准值为0.5γ2.1米。结构的重要度系数为022??,不考虑积灰荷载、风荷载,不考虑全跨荷载积雪不均匀分布m,雪荷载为0.350.2 kN kNm状况。屋架采用Q235B,焊条采用E43型。 2.屋架形式及几何尺寸 1′°2618=檩距arctan,=屋架形式及几何尺寸如图檩条支承于屋架上弦节点。屋架坡角为α3。为1.866m 屋架形式和几何尺寸1 图 支撑的布置3.上、下弦横向水平支撑设置在厂房两端和中部的同一柱间,并在相应开间的屋架跨中设置垂直支撑,在其余开间的屋架上弦跨中设置一道通长的刚性细杆,下弦跨中设置一道通长的柔性细。2杆。在下弦两端设纵向水平支撑。支撑的布置见图

'. . 图2 支撑的布置图 4.檩条布置 檩条设置在屋架上弦的每个节点上,间距1.866m。因屋架间距为6m,所以在檩条跨中设一道直拉条。在屋脊和屋檐分别设置斜拉条和撑杆。 荷载标准值5.35.31kN6=×6×=0.51.77××=0.5×1.866P上弦节点恒

荷载标准值110√3×61.866×0.35=60.35=×1.77×=3.72kN×P上弦 节点雪荷载标准值210√3 由檩条传给屋架上弦节点的恒荷载如图 上弦节点恒荷载图3 由檩条传给屋架上弦节点的雪荷载如图4 '. . 图4 上弦节点雪荷载 6.内力组合 内力组合见表—1

加油站钢结构毕业设计计算书(网架结构)

潍坊学院本科毕业设计(论文) 目录 目录 (Ⅰ) 摘要及关键词 (1) Abstract and Keywords (2) 前言 (3) 1、结构设计基本资料 (4) 1.1 工程概况 (4) 1.2 设计基本条件 (4) 1.3 本次毕业设计主要内容 (6) 2、结构选型与初步设计 (7) 2.1 设计资料 (7) 2.2 网架形式及几何尺寸 (7) 2.3 网架结构上的作用 (9) 2.3.1静荷载 (9) 2.3.2活荷载 (9) 2.3.3地震作用 (10) 2.3.4荷载组合 (10) 3、结构设计与验算 (11) 3.1 檩条设计 (11) 3.2 网架内力计算与截面选择 (18) 3.3 网架结构的杆件验算 (20) 3.3.1 上弦杆验算 (20) 3.3.2 下弦杆验算 (21) 3.3.3 腹杆验算 (23) 3.4 焊接球节点设计 (24) 3.5 柱脚设计 (27) 3.6 钢柱设计与验算 (29) 3.7钢筋混凝土独立基础设计 (32) 3.8网架变形验算 (39)

潍坊学院本科毕业设计(论文) 结束语 (41) 参考文献 (43) 附录(文献翻译) (44) 谢辞 (49)

摘要及关键词 摘要本次毕业设计为合肥地区加油站钢结构设计,此次设计主要进行的是结构设计部分。本次设计过程主要分为三个阶段: 首先,根据设计任务书对本次设计的要求,通过查阅资料和相关规范确定出结构设计的基本信息,其中包括荷载信息、工程地质条件等。 然后,根据设计信息和功能要求进行结构选型并利用空间结构分析设计软件MST2008进行初步设计。本次设计主体结构形式采用正放四角锥网架结构,节点形式采用焊接球节点,支撑形式采用四根钢柱下弦支撑,基础形式采用柱下混凝土独立基础。 最后,通过查阅相关规范和案例进行檩条、节点、支座等部分的设计,并通过整理分析得出的数据,进行了杆件、结构位移等的相关验算,最终确定了安全、可行、经济的结构模式。 关键词结构设计,网架结构,构件验算

某多高层钢结构住宅毕业设计含计算书、建筑结构设计图

雅居乐 多高层钢结构住宅方案设计

1.工程概况 工程名称:雅居乐多高层钢结构住宅; 建设地点:东莞市区某地; 工程概况:场地大小为30m×30m,8~12层,建筑总高度不超过40m,室内外高差为0.3m,设计使用年限为50年; 基本风压:0ω=0.8kN/m2,地面粗糙程度为C类; 抗震要求:抗震设防类别为丙类,抗震设防烈度为8度,Ⅱ类场地土,设计地震分组为第一组。 场地土层情况: 表2-1 场地土层情况 2.建筑与结构布置 3.1.建筑布置 3.1.1.首层建筑平面图 如下图3-1所示,首层平面设计为大空间的形式,可以用此空间做为店面,即商住两用住宅。中间设计为过道、楼梯和电梯。由过道和墙把首层建筑分开为四个大空间,作为四爿店。由于商业的要求,首层平面将进行比较豪华的装修,例如钢柱将外包为方柱,而墙也做成玻璃幕墙与装饰墙混合的形式。此外,门也将用比较好看的旋转门,以吸引顾客。

图3-1 首层建筑平面图 3.1.2.标准层平面图 如下图3-2所示,标准层平面设计为商品房,以中间两墙为分隔墙,分为四户。朝北两户面积较小,内设一个客厅,四个卧室,两个卫生间,一个厨房,一个阳台(左右侧阳台以一墙分开)。而朝南两户面积较大,内设一个客厅,五个卧室,一个书房,一个厨房,两个卫生间,一个杂物间,一个独立阳台。此外,左右两户为于中间墙对称。

图 3-2 标准层平面图 3.1.3.顶层平面图 如下图3-2所示,顶层设计为空旷的天台,外围有1.2m的女儿墙,屋檐外挑500mm。

图3-3 顶层平面图3.1.4.剖面图

图3-4 剖面图1

钢结构课程设计梯形钢屋架计算书

-、设计资料 1、某工厂车间,采用梯形钢屋架无檩屋盖方案,厂房跨度取27m,长度为102m,柱距6m。采用1.5m×6m预应力钢筋混凝土大型屋面板,保温层、找平层及防水层自重标准值为1.3kN/m2。屋面活荷载标准值为0.5kN/m2,雪荷载标准值0.5kN/m2,积灰荷载标准值为0.6kN/m2,轴线处屋架端高为1.90m,屋面坡度为i=1/12,屋架铰接支承在钢筋混凝土柱上,上柱截面400mm×400mm,混凝土标号为C25。钢材采用Q235B级,焊条采用E43型。 2、屋架计算跨度: Lo=27m-2×0.15m=26.7m 3、跨中及端部高度: 端部高度:h′=1900mm(端部轴线处),h=1915mm(端部计算处)。 屋架中间高度h=3025mm。 二、结构形式与布置 屋架形式及几何尺寸如图一所示: 2、荷载组合 设计桁架时,应考虑以下三种组合: ①全跨永久荷载+全跨可变荷载 (按永久荷载为主控制的组合) :全跨节点荷 载设计值:F=(1.35×3.12+1.4×0.7×0.5+1.4×0.9×0.6) ×1.5×6 =49.122kN 图三桁架计算简图 本设计采用程序计算结构在单位节点力作用下各杆件的内力系数,见表一。

1、上弦杆: 整个上弦杆采用相等截面,按最大设计内力IJ 、JK 计算,根据表得: N = -1139.63KN ,屋架平面内计算长度为节间轴线长度,即:ox l =1355mm ,本屋架为无檩体系,认为大型屋面板只起刚性系杆作用,不起支撑作用,根据支撑布置和内力变化情况,取屋架平面外计算长度oy l 为支撑点间的距离,即: oy l =3ox l =4065mm 。根据屋架平面外上弦杆的计算长度,上弦截面宜选用两个不等肢角钢,且短肢相并,如图四所示: 图四 上弦杆

8米高广告牌钢结构设计计算书

8米高广告牌钢结构设计计算书 1 基本参数 1.1广告牌所在地区: 福州地区; 1.2地面粗糙度分类等级: 按《建筑结构荷载规范》(GB50009-2001) A类:指近海海面和海岛、海岸、湖岸及沙漠地区; B类:指田野、乡村、丛林、丘陵以及房屋比较稀疏的乡镇和城市郊区; C类:指有密集建筑群的城市市区; D类:指有密集建筑群且房屋较高的城市市区; 依照上面分类标准,本工程按B类地形考虑。 2 广告牌荷载计算 2.1广告布广告牌的荷载作用说明: 广告牌承受的荷载包括:自重、风荷载、雪荷载以及活荷载. (1)自重:包括广告布、杆件、连接件、附件等的自重,可以按照400N/m2估算: (2)风荷载:是垂直作用于广告牌表面的荷载,按GB50009采用; (3)雪荷载:是指广告牌水平投影面上的雪荷载,按GB50009采用; (4)活荷载:是指广告牌水平投影面上的活荷载,按GB50009,可按500N/m2采用; 在实际工程的广告牌结构计算中,对上面的几种荷载,考虑最不利组合,有下面几种方式,取用其最大值: A:考虑正风压时: a。当永久荷载起控制作用的时候,按下面公式进行荷载组合: S k+=1。35G k +0.6×1。4w k +0.7×1。4S k (或Q k ) b.当永久荷载不起控制作用的时候,按下面公式进行荷载组合:

S k+=1。2G k +1。4×w k +0.7×1.4S k (或Q k ) B:考虑负风压时: 按下面公式进行荷载组合: S k-=1。0G k +1。4w k 2.2风荷载标准值计算: 按建筑结构荷载规范(GB50009—2001)计算: w k+=β gz μ z μ s1+ w ……7.1.1—2[GB50009-2001 2006年版] w k-=β gz μ z μ s1- w 0 上式中: w k+ :正风压下作用在广告牌上的风荷载标准值(MPa); w k- :负风压下作用在广告牌上的风荷载标准值(MPa); Z:计算点标高:8m; β gz :瞬时风压的阵风系数; 根据不同场地类型,按以下公式计算(高度不足5m按5m计算): β gz =K(1+2μ f ) 其中K为地面粗糙度调整系数,μ f 为脉动系数 A类场地:β gz =0。92×(1+2μ f )其中:μ f =0.387×(Z/10)—0。12 B类场地:β gz=0.89×(1+2μ f ) 其中:μ f =0.5(Z/10)-0。16 C类场地:β gz =0.85×(1+2μ f ) 其中:μ f =0.734(Z/10)-0.22 D类场地:β gz =0。80×(1+2μ f ) 其中:μ f =1。2248(Z/10)—0.3 对于B类地形,8m高度处瞬时风压的阵风系数: β gz =0.89×(1+2×(0。5(Z/10)—0。16))=1.8123 μ z :风压高度变化系数; 根据不同场地类型,按以下公式计算: A类场地:μ z =1。379×(Z/10)0。24 当Z〉300m时,取Z=300m,当Z〈5m时,取Z=5m; B类场地:μ z =(Z/10)0.32

钢结构屋架设计计算书Word 文档

1.设计资料 某车间厂房总长度约为108米,跨度为18m。车间设有两台30吨中级工作制吊车。车间无腐蚀性的介质。该车间为单跨双坡封闭式厂房,屋架采用三角形豪式钢屋架。屋面坡度为1:3,屋架间距为6m,屋架下弦标高为9米,其两端铰支于钢筋混凝土柱上,上柱截面尺寸为 ,混泥土强度等级为C20。屋面采用彩色压型钢屋板加保温层屋面,C型檩条,檩距为1.5~2.1米。结构的重要度系数为,屋面的恒荷载的标准值为。屋面 的活荷载为,雪荷载为,不考虑积灰荷载、风荷载,不考虑全跨荷载积雪不均匀分布状况。屋架采用Q235B,焊条采用E43型。 2.屋架形式及几何尺寸 屋架形式及几何尺寸如图檩条支承于屋架上弦节点。屋架坡角为,檩距为 1.866m。 图1 屋架形式和几何尺寸 3.支撑的布置 上、下弦横向水平支撑设置在厂房两端和中部的同一柱间,并在相应开间的屋架跨中设置垂直支撑,在其余开间的屋架上弦跨中设置一道通长的刚性细杆,下弦跨中设置一道通长的柔性细杆。在下弦两端设纵向水平支撑。支撑的布置见图2。

图2 支撑的布置图 4.檩条布置 檩条设置在屋架上弦的每个节点上,间距1.866m。因屋架间距为6m,所以在檩条跨中设一道直拉条。在屋脊和屋檐分别设置斜拉条和撑杆。

5.荷载标准值 上弦节点恒荷载标准值 上弦节点雪荷载标准值 由檩条传给屋架上弦节点的恒荷载如图3 图3 上弦节点恒荷载由檩条传给屋架上弦节点的雪荷载如图4 图4 上弦节点雪荷载6.内力组合 内力组合见表—1 杆件名称杆件编 号 恒荷载及雪荷载半跨雪荷载内力组合最不利 荷载 (kN)内力 系数 恒载 内力 (kN) 雪载 内力 (kN) 内力 系数 半跨雪 载内力 (kN) 1.2恒+ 1.4雪 (kN) 1.2恒+ 1.4半跨 雪(kN)123452+32+5 上弦杆1-2-14.23-75.56 -52.94 -10.28-38.24 -164.78 -144.21 -164.78 2-3-12.65-67.17 -47.06 -8.7-32.36 -146.49 -125.92 -146.49 3-4-11.07-58.78 -41.18 -7.11-26.45 -128.19 -107.57 -128.19 4-5-9.49-50.39 -35.30 -5.53-20.57 -109.89 -89.27 -109.89 5-6-7.91-42.00 -29.43 -3.95-14.69 -91.60 -70.97 -91.60 下弦杆1-713.571.69 50.22 9.7536.27 156.33 136.8 156.33 7-813.571.69 50.22 9.7536.27 156.33 136.8 156.33 8-91263.72 44.64 8.2530.69 138.96 119.43 138.96 9-1010.555.76 39.06 6.7525.11 121.59 102.06 121.59 10-11947.79 33.48 5.2519.53 104.22 84.69 104.22

钢结构桁架设计计算书概况

renchunmin 一、设计计算资料 1. 办公室平面尺寸为18m×66m ,柱距8m ,跨度为32m ,柱网采用封闭结合。火灾危险性:戊类,火灾等级:二级,设计使用年限:50年。 2. 屋面采用长尺复合屋面板,板厚50mm ,檩距不大于1800mm 。檩条采用冷弯薄壁卷边槽钢C200×70×20×2.5,屋面坡度i =l /20~l /8。 3. 钢屋架简支在钢筋混凝土柱顶上,柱顶标高9.800m ,柱上端设有钢筋混凝土连系梁。上柱截面为600mm×600mm ,所用混凝土强度等级为C30,轴心抗压强度设计值f c =1 4.3N /mm 2。 抗风柱的柱距为6m ,上端与屋架上弦用板铰连接。 4. 钢材用 Q235-B ,焊条用 E43系列型。 5. 屋架采用平坡梯形屋架,无天窗,外形尺寸如下图所示。 6. 该办公楼建于苏州大生公司所 属区内。 7. 屋盖荷载标准值: (l) 屋面活荷载 0.50 kN /m 2 (2) 基本雪压 s 0 0.40 kN /m 2 (3) 基本风压 w 0 0.45 kN /m 2 (4) 复合屋面板自重 0.15 kN /m 2 (5) 檩条自重 查型钢表 (6) 屋架及支撑自重 0.12+0. 01l kN /m 2 8. 运输单元最大尺寸长度为9m ,高度为0.55m 。 二、屋架几何尺寸的确定 1.屋架杆件几何长度 屋架的计算跨度mm L l 17700300180003000=-=-=,端部高度取mm H 15000=跨中高度为mm 1943H ,5.194220 217700 150020==?+ =+=取mm L i H H 。跨中起拱高度为60mm (L/500)。梯形钢屋架形式和几何尺寸如图1所示。

广告牌杆件计算

广告牌杆件计算 基本参数: 1:计算点标高:8m; 2:力学模型:悬臂梁; 3:荷载作用:均布荷载(有拉杆作用); 4:悬臂总长度:L=8000mm,受力模型图中a=1000mm,b=7000mm; 5:拉杆截面面积:6287mm2 6:分格宽度:B=1500mm; 7:悬臂梁材质:Q235; 本处杆件按悬臂梁力学模型进行设计计算,受力模型如下: 1.1结构的受力分析: (1)荷载集度计算: q k:组合荷载作用下的线荷载集度标准值(按矩形分布)(N/mm); q:组合荷载作用下的线荷载集度设计值(按矩形分布)(N/mm); S k:组合荷载标准值(MPa); S:组合荷载设计值(MPa); B:分格宽度(mm); q k=S k B =0.002069×1500 =3.104N/mm q=SB =0.002817×1500 =4.226N/mm (2)拉杆轴力计算: 由于拉杆在广告牌外力作用下在铰接点产生的位移量在垂直方向上的矢量代数和等于拉杆在轴力作用下产生的位移量在垂直方向上的矢量即: P:拉杆作用力在垂直方向上的分力(N); qL4(3-4a/L+(a/L)4)/24EI-Pb3/3EI=PL拉杆/EA E:材料的弹性模量,为206000MPa; L拉杆:拉杆的长度; A:拉杆截面面积(mm2); P=qL4A(3-4a/L+(a/L)4)/8(Ab3+3L拉杆I) =15751.273N 拉杆的轴向作用力为: N=P/sinα =31517.037N (3)广告牌杆件截面最大弯矩处(距悬臂端距离为x处)的弯矩设计值

计算: M max:悬臂梁最大弯矩设计值(N·mm); x:距悬臂端距离为x处(最大弯矩处); q:组合荷载作用下的线荷载集度设计值(按矩形分布)(N/mm); L:悬臂总长度(mm); a、b:长度参数,见模型图(mm); 经过计算机的优化计算,得: x=8000mm |M max|=|P(x-a)-qx2/2| =24973089N·mm 1.2选用材料的截面特性: (1)悬臂杆件的截面特性: 材料的抗弯强度设计值:f=215MPa; 材料弹性模量:E=206000MPa; 主力方向惯性矩:I=102584500mm4; 主力方向截面抵抗矩:W=658260mm3; 塑性发展系数:γ=1.05; (2)拉杆杆件的截面特性: 拉杆的截面面积:A=6287mm2; 材料的抗压强度设计值:f1=215MPa; 材料的抗拉强度设计值:f2=215MPa; 材料弹性模量:E=206000MPa; 1.3梁的抗弯强度计算: 抗弯强度应满足: N L/A+M max/γW≤f 上式中: N L:梁受到的轴力(N); A:梁的截面面积(mm3); M max:悬臂梁的最大弯矩设计值(N·mm); W:在弯矩作用方向的净截面抵抗矩(mm3); γ:塑性发展系数,取1.05; f:材料的抗弯强度设计值,取215MPa; 则: N L=Pctgα =27298.737N N L/A+M max/γW=27298.737/9351+24973089/1.05/658260 =39.051MPa≤215MPa 悬臂梁抗弯强度满足要求。 1.4拉杆的抗拉(压)强度计算: 校核依据: 对于受拉杆件,校核:N/A≤f

抗风倾覆稳定性计算书(幕墙和广告牌立柱、地脚螺栓、地基等抗倾覆稳定性计算大全)

抗风倾覆稳定性计算书 案例一:广告牌计算书SAP2000 案例二:广告牌计算书PKPM-STS 案例三:单柱或多柱广告塔主要结构造型计算 附件一:螺栓强度核算表 附件二:基础抗风稳定性简易计算 附件三:广告牌地脚螺栓强度简易核算 广告牌计算书SAP2000 一、工程概况 本工程为一广告牌,该广告牌为立体桁架组成的结构体系,桁架采用角钢连接。 二、设计所依据的规范 1、户外广告设施钢结构技术规程(CECS148-2003) 2、建筑结构荷载规范(GB50009-2001) 3、钢结构设计规范(GB50017-2003) 4、钢结构高强度螺栓连接的设计、施工及验收规程(JGJ82-91) 三、荷载情况 1、恒载:结构自重程序自动计入 2、活载:0.35kN/m2 3、基本雪压:0.3kN/m2 4、基本风压:Wo=0.35kN/m,地面粗糙度:C类。 5、抗震设防烈度:8度,设计基本地震加速度:0.20g,设计地震分组:第三组 6、水平地震影响系数最大值:0.16 7、建筑物场地类别:Ⅱ类,特征周期值:0.35s,结构阻尼比:0.05 8、抗震等级:三级。 四、总体结构布置形式 1、喷绘图案广告位高度h=4.68m 2、广告牌高H=5m 3、广告牌全长L=30m 五、风荷载计算 1、基本风压ω0=0.35KN/m2 2、标准风压ω=β×K×Kz×ω0=0.77KN/m2 其中:风振系数β=2.3;体型系数K=1.3;风压高度变化系数Kz=0.74

六、计算过程 1、SAP2000整体模型: 2、SAP2000计算喷绘广告位每个柱脚迎风面一根(即轴2处,其他轴线处均等于或小于该轴线)方钢管最大弯矩、剪力、挠度: 由分析可得:最大剪力为32.362KN;最大弯矩为M J=14.9655KN·M;最大挠度为7.86mm