1. INTRODUCTION 简介

Scaffolds are an essential part of any construction project. Scaffold provides safe access for workers to perform various tasks. However improperly built and used scaffold could cause catastrophic accidents. SNEC requires all scaffold platforms on its project site to be designed, built and inspected by competent personnel. This procedure provides safe work practices that are to be used on site when constructing and utilizing scaffolds that are designed to support workers at the project site.

脚手架对于任何项目的建设施工都是十分重要的部分。脚手架使工人能安全地进入到各个作业面。但是没有正确搭建的脚手架和没有恰当使用的脚手架会造成各种灾难性事故。SNEC 要求所有其项目现场使用的脚手架都必须由有资质的人员进行设计,搭建和检验。本程序提供了设计和搭建脚手架的安全作业规程,用于在项目现场给工人提供帮助。

2. DEFINITION OF TERM 术语定义

A) Fixed Scaffolds - includes the following scaffolds commonly used on site: tubular

welded frame, tube and coupler (Tube lox) scaffolds, Quick Erect Systems (QES) scaffolds

固定式脚手架——包括以下通常在现场使用的脚手架:钢管焊接支架、搭扣式脚手架(Tube lox)、速建式脚手架。

B) Suspended Scaffolds - includes the following: two-point suspended scaffolds, multi-

level suspended scaffolds, floats, needle-beam scaffolds, boatswain's chair, and electric hoist platforms and protection fans.

悬式脚手架——包括以下脚手架:两点悬吊式脚手架、多级悬吊式脚手架、浮板、轻型脚手架、高空操作坐板以及电气吊装平台和扇形保护脚手架。

C) Competent Person - One who is capable of identifying existing and predictable

hazards in the surroundings or working conditions related to scaffolding which are hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.

有资质的人员:该人员能够对员工造成危害和危险的脚手架作业环境辨识出已存在的危险和预计可能发生的危险,同时,该人员有权立即采取相关整改措施以消减这些危险

和危害。

D) Scaffold User - One whose work requires them to access a scaffold platform.

脚手架使用人员:指那些必须登上脚手架平台工作的人员。

E) Scaffold Erector - One who has been trained to a level of competency, and designated

to erect scaffolds under the direct supervision of a competent person for scaffolds. He must have a certification of special trade issued by local authority.

脚手架搭建人员:指那些经过训练、达到一定技能水平、在脚手架专业人员的直接指导下进行脚手架搭建的人员。他必须持有权威部门颁发的特殊工种上岗证。

F) Scaffold Inspector - One who has been trained to a level of competency, and

designated to inspect scaffolds and identify deficiencies in scaffolds such as: missing components, structural damage, failed foundation systems, etc., and has authority to stop work pending further review by the scaffold Competent person.

脚手架检验人员:指那些经过培训、达到一定技能水平、被指定从事脚手架检验工作以及辨识脚手架缺陷的人员,如:构件不全、结构损害、基础系统无效等,且有权勒令停工,待脚手架安全专业人员进行进一步审查。

G) Scaffold request form – Must be submitted to the safety department prior to work

commencing and entered in the scaffold register.

脚手架申请单:应在工作开始前提交安全部门并输入脚手架登记表。

3. ROLES, RESPONSIBILITIES AND TRAINING

岗位、职责和培训

A) Scaffold User - has responsibility to attend initial user training, to ensure that scaffolds

used by them have been inspected and to follow all requirements set forth in training and this regulation. Users are authorized to work only on scaffolds, which display a green tag, and an inspection sticker signed and dated (See Attached) by a Scaffold Inspector that day.

脚手架使用人员:有责任参加使用入门培训,确保其所使用的脚手架均经过检验,符合培训内容和本规定的内容。使用者只可在挂有绿色标牌的脚手架上进行作业,同时,脚手架检验员应在该脚手架的当日有效检查标贴纸上签字并注明日期(参见附件)。

All scaffold users shall be trained to recognize the hazards associated with the type of scaffolding being used, and to understand the procedures to control or minimize

those hazards. The training shall include the following areas, as applicable:

所有脚手架使用人员都必须接受相关培训,做到能够察觉正在使用的各类脚手架相应的危险,懂得如何去控制或尽量减少这些危险。培训应根据具体情况包括以下方面的内容:

i) The nature of electrical hazards, fall hazards, and falling object hazards in the

work area.

ii) 工作区域内的电气危险、坠落危险以及落物危险的特性。

iii) The correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection system and falling object

system being used

电气危险防护措施以及所采用的坠落保护系统和落物系统的搭建、维护和拆除的正

确程序。

iv) The proper use of the scaffold, and the proper handling of materials on the scaffold.

脚手架的正确使用方法以及在脚手架上递接材料的正确方法

v) T he maximum intended load and the load-carrying capacities of the scaffolds used.

所采用的脚手架的最大设计荷载以及承载能力。

B) Scaffold Erector - has the responsibility of erecting, modifying, and dismantling

scaffolds under the direct supervision of a Competent Person for scaffolds. The Erector may be trained and designated as a Scaffold Inspector, to perform daily inspections of scaffolds already tagged for use by a Competent Person.

脚手架搭建人员:负责在脚手架专业人员的直接指导下进行脚手架的搭建、修改和拆除。

搭建人员通过相关培训后可指定为脚手架检查人员,负责对由专业人员标识为“可用”

的脚手架进行日常检查。

C) Scaffold Inspector - has the responsibility of inspecting scaffolds prior to use each day.

If the scaffold meets the minimum inspection criteria, the Inspector will sign and date the inspection sticker to authorize use that day. If the scaffold fails the inspection, the Inspector will pull the green tag and replace with red rag, report to the competent person afterwards.

脚手架检查人员:负责每天在脚手架使用前对之进行检查。如果脚手架满足最低检查标

准,则检查人员应在检查标贴纸上签字并注明日期,表明该脚手架当天可用。如果脚手架未通过检查,则检查人员将拿下绿色标牌换上红色标牌,并在事后向专业人员进行汇报。

D) Competent Persons – will be trained as Inspectors, and will typically perform that

function. However, other persons, such as craft foremen may also be trained as Scaffold Inspectors, and perform that role in plant shutdowns and other similar situations.

专业人员:将接受检查人员培训并将专门从事这项工作、履行这一职责。但是,其他人员如工种班长等可也接受脚手架检查人员培训,在工厂停工期间和类似情形下履行检查人员的职责。

E) Scaffold Competent Person - Has the overall responsibility of ensuring that scaffolds

are erected and maintained in accordance with current scaffold erection practices.

The competent person will be present during erection, modification, or dismantling of all scaffolds by scaffold Erectors. The Competent Person will make determination whether a Red or Green tag is displayed (See Attached), and of what duty rating the scaffold deck is built to, making the appropriate notation on the tag.

脚手架专业人员:从总体范围内,负责确保脚手架按当前脚手架搭建规范进行搭建和维护。在脚手架搭建人员搭建、修改和拆除脚手架的时候,专业人员应进行全程监控。专业人员应决定何时该挂红色标牌、何时该挂绿色标牌(参见附件),而且,他们应该决定脚手架平台的负荷系数并在标识牌上作出相应恰当的注解。

F) Professional Engineer - a registered Professional Engineer will be required to design

and approve prior to use, any scaffold built over 20 Meters tall.

专业工程师:凡20米以上的脚手架都要求由有资质的专业工程师设计和批准使用。4. SCAFFOLD DESIGN

脚手架设计

The following are design specifications that all scaffolds must adhere to as a minimum.

所有脚手架的设计必须满足以下最低设计规范要求。

A) All scaffolding that is to be used on the project site must be designed and in

accordance with the manufactures or Professional Engineers guide lines.

所有在项目现场使用的脚手架必须按生产厂商和专业工程师的指令要求进行设计。

B) All fixed scaffolding will be of the tubular welded frame, tube and coupler (Tube lox) a

scaffold, Quick Erect Systems (QES) scaffolds.

所有固定式脚手架必须采用焊接钢管框架、搭扣式脚手架(Tube lox)、速建式脚手架。C) All scaffolding over 20 Meters high is to be designed by a certified /registered

Professional Engineer and relevant qualifications must be provided upon request and or prior to scaffolding being constructed.

所有超过20米高的脚手架都必须由具备相关资质的专业工程师设计,而且,应按要求或在脚手架施工前提供相关资质。

D) Details of general scaffold design must be made available for review and approval by

the Construction Manager prior to any scaffold being constructed or erected.

在进行任何脚手架施工或搭建前,应将脚手架总体设计的详细资料提交施工经理供其审批。

Note: Bamboo scaffolding and or materials are strictly prohibited on the project construction site.

注意:项目施工现场严禁采用毛竹脚手架或类似材料脚手架。

E) All scaffolds will be furnished with handrails and midrail on all sides. Handrails must be

approximately1.2meters above the scaffold platform. Handrails and midrail shall be supported at intervals not to exceed 2.44 meters.

所有脚手架临边都必须带扶手和挡板。扶手应高出脚手架平台约.1.2米。扶手和挡板每隔不超过2.44米应进行支撑。

F) Toe boards are required on all scaffolds. Toe boards to be a minimum of 18 centimeter

in height and tied to the vertical up-right/rail at each corner.

所有脚手架均需踢脚板。踢脚板至少应18公分高,且应绑置在每个角的立杆上。

G) Scaffold planks must be at least 5X25 centimeters of full thickness lumbar or scaffold

grade and or equivalent. Scaffold planks must be supported by a transom every 1.3m.

Scaffold planks that are damaged or are cracked /split are to be rendered unserviceable and destroyed.

脚手架铺板必须采用5×25公分的全厚木材或等同的脚手架材料。这些铺板应每隔1.3米采用横档进行支撑。损坏或破碎/开裂的铺板均不应使用而应予以报废处理。

H) Scaffold planks must be secured in place and or cleared and must extend or protrude

over the end of supports by at least 15 centimeters as a minimum. But not more than

30 centimeters. Securing of planks is to be by metal /steel cable, under no

circumstances is hemp/rope to be used for securing scaffold planks.

脚手架铺板必须稳妥安装,铺板端部应至少伸出支撑15公分,但不得超过30公分。可采用金属线或钢缆固定铺板,在任何情况下,都不得采用麻绳来固定铺板。

I) All scaffolds platform must be at least (3) three planks wide for erection and

dismantling purposes.

所有脚手架用作搭建和拆除施工时,平台至少要铺3块脚手架铺板。

J) Access ladders must be provided for each scaffold. Jumping off the end of frames or over safety handrails is prohibited

每个脚手架应配备一个爬梯,严禁从架子端部或跨越扶手往下跳。

Note: All scaffolds must be designed with access routes in corporate. All ladders attached to scaffolds must be of all approved design. Bamboo ladders are prohibited on the construction site.

注意:所有脚手架必须设计进出路线。脚手架所配的爬梯必须做到设计合理符合规范。施工现场严禁采用毛竹爬梯。

K) Access to scaffolding over 3 frames/levels (6 meters) must have a rest platform or ladder safety devices.

三层(6米)以上的脚手架进出应设置休息平台或配备爬梯安全设施。

L) Adequate sole boards or other rigid footing capable of withstanding the maximum in tended load must be provided.

脚手架的基础板或其他刚性基础必须能承受脚手架最大设计荷载。

Note: All scaffolding shall be designed and constructed utilizing a Safety Factor of (4) four.

A Safety Factor of (4) four meaning that their components shall be capable of supporting without failure At least (4) four times the maximum intended load. Engineering design to show calculations and sketches supporting all of above.

注意:所有脚手架在设计和施工时,其安全系数均应设置为4。这意味着确保脚手架的所有部件能够承受最大设计荷载的4倍。工程设计时应提供相应计算书以及草图。

M) All scaffolds (regardless of where they are constructed) must be equipped with a 15X15 centimeter steel base plates with an internal fixing spigot .Use of adjustable

type support incorporating the above are preferred for use.

所有脚手架(无论施工地点设在何处)都必须配置15×15公分的内插接口钢基础板。

宜采用可调节的支撑。

N) Drums/Barrels/Boxes/kegs and or similar un-stable objects must never be used for scaffolds, and or work platforms to support scaffolds.

脚手架不得采用桶、盒、箱及任何类似不稳定的物体,或者应采用工作平台来支撑脚手架。

O) Where persons are required to work or pass under an existing scaffold. A protective screen of debris netting will be erected.

如果施工人员必须在现有脚手架下方进行作业和有人员从脚手架下方通过的话,则应安装防垃圾的保护网。

P) Overhead protection fans are required if workers are exposed to overhead hazards.

Such protection must be of 5-centimeter thickness type planks or equivalent.

如果工人在存在上空危险的工作环境下工作,则应安装上防护保护。此类防护必须采用5公分厚的脚手架铺板或同等材料。

Note: This type of protection is to be shown clearly on the engineer’s drawings/sketches. 注意:此类防护必须在工程师的图纸或草图上明显表示出来。

5. SCAFFOLD CONSTRUCTION

脚手架施工

Only trained Scaffold Erectors supervised by a Competent Person are allowed to construct scaffolding. These individuals/ workers must be able to read and understand basic engineering drawings relevant to scaffold building construction and all relevant site safety work practices.

只有经过培训的脚手架搭建人员方可在专业人员的监督下进行脚手架施工。这些人员和工人必须能够阅读、看懂脚手架施工的基本工程图纸并理解所有相关现场安全作业规程。Note: No person or sub-contractor is permitted to build or construct any

scaffold without appropriate written approval from the Construction/Project

HSE Manager/Safety Manager.

注意:未经施工经理/项目HSE经理的书面许可,任何人和分包商都不得进行脚手架的施工。

The following will be adhered to during the construction of scaffolds.

在脚手架施工期间应遵守以下规定。

A) All scaffold designs must be approved for use prior to construction and a scaffold

request form submitted to the construction department.

在脚手架施工前,所有脚手架设计应通过审批,且应向施工部提交脚手架申请单。B) There will be no gaps between the scaffold boards or between the scaffold board and

the toe board, unless the scaffold boards are covered with 2 centimeters thick plywood. Transom supports every 1.3 m with check transoms every working lift.

脚手架铺板之间和铺板与踢脚板之间不得存在缝隙,但铺板采用2公分厚三夹板覆盖时除外。每1.3米设横档,每层设竖档。

C) Scaffold boards must be visually inspected before each use. Unserviceable boards

are to be discarded and removed from site.

所有脚手架铺板在每次使用前都必须进行目测。不能使用的铺板应进行废弃处理并运出现场。

D) Scaffold must be tied or attached to the building or structure at intervals that do not

exceed 4 meters horizontally or 4 meters vertically if this is not possible then buttress shoring will be used.

脚手架与建筑或构筑物之间应在横向或竖向每隔不超过4米必须进行绑扎固定,如果无法做到的话,则应采用斜撑系统。

E) Under no circumstances shall any scaffold be modified after the scaffold has been

accepted for use and a green tag attached. Unless approval has been granted by the Scaffold Inspector.

在脚手架经过验收并附上绿色标识牌后,除非获得脚手架检查人员的许可,否则在任何情况下都不得对脚手架进行修改,

All Scaffolding erection and dismantling will be considered as working at elevated height and a safety harness will be used.

脚手架搭建和拆除均应视为高空作业,作业人员应配备安全带。

Note: Persons other than an approved competent Scaffold Erector found removing or tampering with existing scaffolding will be subject to severe disciplinary measures.

注意:一旦发现非脚手架专业搭建人员拆除或修改现有脚手架,则该类人员必须接受严厉的纪律处罚。

F) All suspended scaffolds or platforms must be equipped with a separate vertical safety

anchor, independent of the scaffold system. All workers/personnel must tie off onto this vertical safety anchor whilst working on the scaffold.

所有悬式脚手架和平台应配备单独的竖向安全锚杆,该锚杆应独立于脚手架系统。所有作业人员或工人在脚手架上作业时应与该竖向安全锚杆进行固定。

Note: The vertical safety anchor must have a minimum design safety factor of (4) four.

注意:竖向安全锚固件的最小设计安全系数应达4。

6. SCAFFOLD TAGGING SYSTEM

脚手架标识系统

All scaffolding must utilize a scaffold tagging system to identify the current status of the existing scaffold. (See Attachments)

所有脚手架必须采用脚手架标识系统来识别现有脚手架的当前状态(参见附件)。

Red Tag:红色标识牌

l Under construction正在施工

l Under repair /modification正在修理/修改

l Incomplete 尚未完工

Green Tag:绿色标识牌

100% complete and accepted for use.100%完成并通过验收。

(Note: The style of the tag can be designed by subcontractor themselves ,but must be reformed by SNEC HSE manager and owner before use)

(注: 标示牌样式可由分包商自行设计,但使用前必须经过SNEC HSE经理和业主同意。 ) 7. SCAFFOLD ACCEPTANCE

脚手架验收

Only trained Scaffold Inspectors are allowed to inspect and tag scaffolding on site. All scaffolds are required to be tagged and only authorized personnel can replace tags that have become illegible, worn or damaged or if superceded by another tag.

只有接受过培训的脚手架检查人员方可对现场脚手架进行检查和标识。所有脚手架必须进行标识,而且,只有授权人员才有权更换已不符合要求的、磨损、被损坏或被其他标识代替的

标识牌。

8. SCAFFOLD USE脚手架使用

Once scaffolding has been constructed and accepted for use all Scaffold Users must use it in a safe manner. The following is an outline of safe work practices that should be adopted with on going use of a scaffold.

脚手架一旦完成搭建且经验收认可后,所有脚手架使用者必须按安全规范进行使用。下面对上脚手架作业应采取的安全作业规程做了一个归纳总结:

A) All work on scaffolds greater than 1.8 meters in height must be stopped in rough

weather or high wind speeds. To be determined by Construction Manager/Project Safety Manager.

在恶劣天气和大风季节应禁止在超过1.8米高的脚手架上进行作业。应按施工经理/项目安全经理的指令行事。

B) All scaffolds will be kept free of rubbish and clear of tools and materials.

所有脚手架上不得存放垃圾,及时清理工具和材料。

C) All scaffold platforms are to be kept free of oil & grease act.

在所有脚手架平台上不应进行油和油脂类工作。

D) No materials to be stockpiled on scaffolds.

脚手架不得用于存放任何材料。

E) Tools and materials are not to be thrown from one scaffold to another or from one

person to another or from elevations to the ground.

不应将工具和材料从一个脚手架扔到另一个脚手架和从一个人手里扔向另一个人或者从高处向地上扔。

F) Hand lines and buckets are to be used for raising and lowering light hand tools and

equipment.

应采用吊绳和吊斗进行工具和设备的提升和放低操作。

G) Access ladders are to be used from one scaffold to another.

从一个脚手架到另一个脚手架时应采用爬梯。

Note: Jumping from one scaffold to another is prohibited. Climbing scaffolding on its exterior perimeter is strictly prohibited. Climbing over handrails is strictly prohibited.

注意:不得从一个脚手架跨跳到另一个脚手架上。严禁沿脚手架的外缘攀爬。

不得攀越脚手架扶手。

9. MOBILE SCAFFOLD活动脚手架

The following requirements must be maintained in regards to a Mobile Scaffold.

活动脚手架必须确保满足以下要求

A) The height of a rolling scaffold must not exceed (3) three times the smallest base

dimension.

滚动脚手架的高度不得超出最小基础尺寸的三倍。

B) The work platform must be planked for the full width of the scaffold clears the

underside of planks to prevent their movement.

作业平台的铺板必须铺满脚手架, 铺板侧面应结合地密实,防止铺板活动。

C) Castor brakes must be locked when the scaffold is not in motion.

当脚手架不动时应锁定脚轮刹车。

D) Get help when moving rolling scaffolds ensure route is clear. Watch for holes and

overhead obstructions.

在移动滚动脚手架时应获取必要帮助以确保所有移动路线明确清楚。注意孔洞和高空障碍。

E) Remove all materials and equipment prior to moving scaffold.

在移动脚手架前应先清除脚手架上的材料和设备。

F) No persons are permitted to ride on a rolling scaffold.

任何人不得在乘骑在滚动脚手架上。

10. SCAFFOLD ALTERATIONS

脚手架改装

Sometimes part of a green tagged scaffold platform need to be altered to perform certain tasks. If such need arises, users are strictly prohibited do carry out this modification by themselves. The following steps must be followed if existing scaffold platform need to be altered;

有时需要对部分绿色标签的脚手架平台进行改装以适合特定施工使用。如果出现这种情况,严禁使用者自行进行改装工作。如果需要对现存的脚手架进行改装,一定要遵守下述步骤:

A) Users must contact with their Line Supervisor on the need to modify scaffold

platform.

使用者需要改装脚手架平台时须与其主管经理联系。

B) Line Supervisor either directly or through their manager will contact Scaffold

Competent Person on the need to modify scaffold.

主管经理直接或通过上级经理联系合格脚手架人员有改装需要。

C) Competent Person will review the requirement, re-design and approve the

changes.

合格人员对改装、设计进行审核并批准。

D) The changes will be carried out ONLY by Scaffold Erectors.

改装只能由脚手架安装工进行。

E) After alteration, the scaffold platform will re-inspect and green tagged by Scaffold

Inspector.

改装完毕后,由脚手架检查员重新检查并发给绿标签。

F) Once the above processes are completed, user can resume using the platform.

上述步骤完毕,使用者可恢复使用改装过的脚手架平台。

11. SCAFFOLDER BASIC TOOL KIT

架子工基本工具包

l Safety Belt

安全带

l Ratchet spanner for clip adjustment

用于调整夹具的棘轮扳手

l Small hand level

小型手持式水准仪

l Measuring tape.

皮尺

l P.P.E.

个人防护设施

12. Scaffold tag model

Green Tag

Red Tag

13. SCAFFOLDING CHECKLIST

脚手架检查核对清单

SCAFFOLD INSPECTION CHECK LIST

脚手架检查核对清单

Platform:平台:Date:日期:

Location:地点:Inspector:检查人员:

Scaff. Ref. No.: 脚手架编号

INDEPENDENT & CANTILEVER SCAFFOLD

独立式及悬臂脚手架

Compliance符合情况Item

No.

编号Items to be Inspected待检查项目

Yes

No

Description of

faults to be

rectified

待整改缺陷描述

Date

rectified

整改日期

1 Is foundation/deck/soleplates satisfactory?

基础、平台和底板是否符合要求

2 Check Scafftag reference no. and status.

检查脚手架标识牌编号和状况

3 Check that scafftag is clearly displayed at point of entry

onto scaffold.

检查脚手架标识牌是否挂在脚手架进口的显眼处

4 Check spacing of upright tubes to suit super-imposed

loading indicated on scafftag.

检查立管的间距是否能确保达到脚手架标识牌上规定的高承载能力

5 Bottom/base lift installed. Lift heights @ 2000 mm

generally.安装了底座吊柱,底层高度一般为2000mm.

6 Ledgers fixed to uprights with load bearing coupler.

用承载扣件将横木固定到立管上

7 Check Transom centres - generally 1220mm maximum

centres..

检查横档中心距,通常最大距中距离为1220mm.

8 Check that 1 no. transom tube occurs at ledger to

upright nodes fixed with load bearing coupler.

检查立管节处横杆上是否有一根横杆与承载扣件相固定。

9 Check ledger bracing is fixed at alternative pairs of

uprights full height at upright lines.

每隔两根立管沿立管全高绑固横撑

10 Check that face bracing is installed full height of scaffold

(every 30m minimum).

脚手架整个高度范围内安装了面撑(最少每隔30米)

11 Check scaffold boards, condition, tied down securely

minimum bearing length 50mm, 150mm maximum.

Check gaps.

检查脚手架铺板状况、安装是否稳固,最小承载长度是否

达到50mm,最大是否不超过150mm,检查脚手架铺板间

缝隙

12 Check ties (is existing main structure capable of

reactions), load bearing couplers. If ties are not installed in accordance with regulations, buttressing or plan bracing back to main structure is required for stability. Ties must be located at upright/ledger node points (strong points of scaffold).

检查拉杆(它是当前主要反作用结构)、承载扣件。如果

未按规定安装拉杆、则应对主结构采用扶壁或平面支撑来

确保稳定性。拉杆必须设在立管与横档交接点处。(脚手

架的稳固位置)

13 Check guardrails and toe boards.

检查护栏和踢脚板

14 Check ladder access, securely tied, caged in for safety if

required. Ladders must project at least 1050mm above boarded deck.

检查爬梯是否稳妥安置,必要时,还应带有环状围护。梯子至少应高出登陆平台上1050mm.

15 Joints in uprights and ledger tubes must be staggered.

立管和横档的接头应交错设置。

16 If ledger bracing is omitted at base lift to allow clear

access through scaffold. Scaffold must be tied at 1st lift level.

如果脚手架底层出于提供进出空间的目的未安装横撑,则应在二层设置脚手架拉杆。

17 Check that no loose materials are left on scaffold lifts.

检查脚手架各层,确保脚手架上不存有松散材料。

18 If scaffold requires sheeting, consult Design Engineers

as scaffold requires strengthening plus additional ties to withstand wind forces.

如果脚手架必须铺板,则应与设计工程师咨询,查证脚手架所需强度以及增加拉杆的必要性以确保能够承受风荷载。

19 Any special/heavy duty loadings imposed onto scaffold

must be approved by Design engineer, Design Drawing and calculations may be required.

在脚手架上施加任何特殊或重型负荷,都必须获得设计工程师的认可,必须提供设计图纸和计算书。

20 Check width of cantilever if applicable.

如果必要的话,应检查悬梁宽度。

21 Check that ties are fitted to main structure at cantilever

level.

检查拉杆是否与在悬梁高度主结构拉接。

22 Check transoms are butting against structure at base of

cantilever raker.

检查悬梁斜撑底部的横档是否与结构相连

脚手架管理规定60817

脚手架管理规定 1.目的和范围 1.1为贯彻落实JGJ130-2001《扣件式钢管脚手架安全技术规范》,以预防操作人员高处坠落、脚手架倒塌、物体打击等事故的发生制定本规定。 1.2本规定适用于独山子区新建、改建、扩建的房屋建筑和维护工程、装饰装修和市政基础设施的施工用脚手架工程管理。 2.职责 2.1施工总承包单位 2.1.1施工总承包单位负责督促分包单位在工程施工过程中及时搭设脚手架和各类操作平台; 2.1.2施工总承包单位安全负责人审核并督促各分包单位办理各类脚手架搭拆申报手续; 2.1.3施工总承包单位负责协调各分包单位的安全生产管理工作,定期支付脚手架搭设所需费用,并督促其专项费用的落实,发现问题督促整改; 2.1.4施工总承包单位负责定期组织各分包单位,对脚手架、操作平台及其各施工部位的安全措施情况进行专项检查,督促完善其安全措施。 2.2施工分包单位 2.2.1施工分包单位应根据工程实际情况及时编制脚手架搭拆专项方案,经安全技术负责人审核后,报总包和监理单位审批。搭拆脚手架前必须按规定提前申报作业票,经相关人员审批后方可作业。 2.2.2施工分包企业安全生产部门每月、项目部每半月对施工现场脚手架的安全稳定性和架体安全防护进行不少于一次的专项检查,并做好检查记录; 2.2.3项目专职安全员负责督促技术负责人对脚手架作为业人员进行安全技术交底,对脚手架搭设完毕后组织脚手架班组长、使用脚手架班组长及相关人员对脚手架进行检查验收,合格后悬挂验收牌。并每天对脚手架的安全状况、架体围护和操作平台的安全防护工作进行检查,发现问题及时要求各班组进行整改,并做好检查验收记录; 2.2.4架子工班组根据施工进度申报脚手架作业票,及时搭拆脚手架。在搭设脚手架前应按专项方案对班组成员进行班前教育和有关安全技术知识学习,搭设完毕后班组应进行自检,合格后报告项目安全员,由安全员组织相关人员进行验收,合格后参验人员在验收单上签字。并报监理单位检查签认,合格后方可使用。 2.3监理单位 2.3.1监理单位应对施工单位上报的脚手架搭拆方案和安全措施、脚手架作业票进行审批,并对其脚手架施工作业的安全工作负责; 2.3.2监理单位和现场监理人员对建设工程施工脚手架及操作平台的搭拆,实施全过程监理;对脚手架作业票、验收表(见附表)、验收牌(见附表)进行检查签认。 2.3.3监理单位对建设单位拨付给施工单位的安全生产措施费用进行监理,监督其专款专用。对未聘请监理的小工程由建设单位或投资方个人行使对施工方的安全监管职责。 2.4项目主管部门 负责对施工单位搭拆和使用脚手架的安全工作进行定期检查,并及时足额提供保证安全作业环境及安全施工措施所需费用,并对其费用的使用进行定期检查,确保安全措施费用的落实。 2.5安全监察部门 2.5.1负有在各自的职责范围内履行安全监督检查管理的职责,依法对生产经营单位执行有关安全生产的法律法规和国家标准和行业标准的情况进行监督检查。

脚手架搭设施工方案

一、工程概况 敦化站处于吉林省延边朝鲜族自治州敦化市,属于铁路客运候车楼。总建筑面积4997㎡。采用钢筋混凝土框架结构,屋顶为钢网架结构。地下局部设有消防水池、设备间,底板结构标高为-6.0m和-5.0m两种;地上结构两层,局部有大空间。根据工程情况,站房雨棚顶高17.5m,采用双排钢管结构脚手架对该工程进行施工防护,密目网围护,支架高度为18.5m。 二、施工工艺流程 本工程采用扣件式钢管脚手架,脚手架为双排脚手架,取最大搭设高度18.5米进行计算,1-4、9-12轴周边搭设到12m高,4-9轴到16m标高处。本标高相对四周原地面标高。D轴原地面标高需要处理。 搭设尺寸为:立杆离柱子外边0.6m为第一排脚手架,1.8m为第二排脚手架,立杆的纵距1.50米,立杆的横距1.20米,扫地杆0.3m,立杆的步距1.80米。 施工工艺流程:放线→摆放扫地杆→逐根竖立杆底托放垫木→随即与扫地杆扣紧→装扫地小横杆或大横杆与竖杆扣紧→安第一步大横杆→安第一步小横杆→安第二步大横杆→安第二步小横杆→架设临时斜横杆→安第三步大小横杆→一次类推→安立杆连接件→架设剪刀撑、铺脚手板张挂安全网→验收使用。 三、施工组织与部署 1、质量目标:保证本工程一次交验达到合格标准。

2、进度、成本目标:争取在2012年10月31日按进度计划,主体结构封顶时完成。为便于门窗安装及时插入施工,本工程在主体砼结构完成后,及时插入门窗安装、水电暖、室内外装修施工。合理组织各工种穿插流水作业,按工序流水施工,使工程总成本降至最低。 3、安全质量目标:伤亡事故确保为零;轻伤控制频率在2‰以下; 4、文明施工目标: 认真贯彻实施国家建设部《建筑施工安全检查标准》(JGJ59-2011)要求和国家有关卫生的标准、规范,划分职责,严格总平面管理及进出场安全保卫工作,确保文明施工目标的实现。 四、材料准备 1、脚手架钢管采用Φ48mm,壁厚 3.5mm;横向水平杆最大长度1500mm,其它杆最大长度6000mm,且每根钢管最大质量不应大于25kg。 2、钢管尺寸和表面质量应符合下列规定 (2)钢管上禁止打眼。

脚手架作业安全管理实施细则(通用版)

脚手架作业安全管理实施细则 (通用版) Safety management is an important part of enterprise production management. The object is the state management and control of all people, objects and environments in production. ( 安全管理 ) 单位:______________________ 姓名:______________________ 日期:______________________ 编号:AQ-SN-0574

脚手架作业安全管理实施细则(通用版) 第一章总则 第一条为规范长庆油田分公司水电厂(以下简称水电厂)所辖生产生活区域等施工作业中的有关脚手架作业的安全管理,防止脚手架坍塌、高处坠落等事故的发生,依据《长庆油田分公司脚手架作业安全管理办法》以及国家相关法律法规、技术规范标准等,特制定本细则。 第二条脚手架是一种临时搭设的、可供人员在其上施工、承载建筑、设备和物料的平台。 第三条本细则适用于水电厂所属各单位(包括厂监管的多元经济单位)及承揽水电厂施工任务承包商的任何金属(木)脚手架作业活动,包括搭建、拆卸、移动、提升、改建和使用脚手架作业。

第二章脚手架作业管理要求 第四条脚手架作业实行作业许可制度,应办理作业许可手续(应有许可票见附件),并详细说明作业范围、确定危害和评估风险、制定相应防范措施和应急预案。 第五条由各业务主管部门或基层单位负责人组织生产及施工单位有关人员进行现场调查,识别脚手架作业对生产区域的具体影响,进行工作安全分析,提出预防措施和应急措施。 第六条由施工单位编写脚手架作业方案和应急预案,按照等级划分逐级办理作业许可票,批准后方可进入生产区域进行脚手架作业。 第七条施工单位应具有脚手架作业相关资质;脚手架作业人员应经过培训并具有相应资质;患有心脏病、高血压、癫痫病等不适宜高处作业的人员不允许进行脚手架作业。 第八条凡是没有办理作业许可手续、没有落实作业安全措施、未设现场作业监护人以及脚手架作业方案有重大变动且未经批准的,一律禁止作业。作业期间,如发现异常情况,应立即停止作业。

脚手架安全管理规定

脚手架安全管理规定 为了加强对脚手架施工全过程的控制和管理,进一步规范脚手架的搭设、拆除,材料的验收及使用中的各项安全管理要求,强化对危险性较大和特殊脚手架施工过程的安全管理,有效控制安全生产事故,最大限度地保障操作工人的人身安全,减少企业风险,特制定本规定。 一、适用范围: 本规定适用公司所属各单位和施工现场(含联营和各种形式承包的工程项目部)。 二、编制依据: 1、《建筑施工高处作业安全技术规范》JGJ80-91 2、《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2001 3、《安全网》GB5725---1997 4、《密目式安全立网》GB16909---1997 5、《北京市建设工程施工现场安全防护标准》 6、《建筑施工安全检查标准》JGJ59-99 7、北京市建筑工程总公司《脚手架安全技术操作规程》 8、《北京建工集团施工现场创建达标管理办法》 9、《三建公司文明施工达标执行标准》 三、脚手架安全管理要求: (一)材料、材质的安全管理要求: 1、钢管:

脚手架钢管应采用《直缝电焊钢管》或《低压流体输送用焊接钢管》。钢管应采用:外径48-51mm,壁厚3.0-3.5mm,长度为4-6m和2.1-2.3m,每根钢管的最大质量不应大于25kg的钢管。钢管必须做防锈处理,并涂桔黄色油漆。 2、扣件: 扣件应采用可锻铸铁制作的扣件,规格必须与钢管外径尺寸相同,扣件无论新旧均应进行防锈处理,直角扣件自重应为13.2N/个、旋转扣件自重应为14.6 N/个、对接扣件自重应为18.4N/个。 3、脚手板: 脚手板可采用钢、木材料制作,每块质量不宜大于30kg。冲压钢脚手板应有防滑措施,脚手板无论新旧均应涂防锈漆。木制脚手板应采用杉木或松木制作,宽度不宜小于200mm,厚度不应小于50mm。 4、安全网: 大眼网必须采用锦纶材料编制,宽度不得小于3米,长度不大于6米,网眼不得大于10cm;密目网网目密度不应低于2000目/100cm2,密目网各边缘部位的开眼环扣必须牢固可靠,环扣孔径不低于8mm,网体必须阻燃。 (二)采购与租赁的安全管理要求: 各工程项目必须从在北京市建委备案的生产、租赁企业中采购或租用钢管、扣件。在采购和租用钢管、扣件时,要与生产或租赁单位签订质量担保协议,查验和保存生产许可证、产品合格证、检测报告等有关资料。各施工项目要采取有效措施增强钢管质量的可控性和质量责任的可追溯性。

脚手架安全管理规定

脚手架安全管理规定 密级:□项密一级 □项密二级 □项密三级 密 文件编号:CCSC-P02-13 中煤陕西榆林能源化工有限公司 CHINACOAL SHAANXI YULIN ENERGY & CHEMICA L CO., LTD. 煤化工项目管理体系文件

文件会签表 说明: (1) 本管理体系文件知识产权属中煤陕西榆林能源化工有限公司所有,未经授权许可或批 准,不得对公司以外任何组织或个人提供;任何外部组织或个人擅自获取、使用、转 让本管理体系文件的行为均属侵权。 (2) 本管理体系文件执行解释权在HSE部。

目录 1目的 (1) 2适用范围 (1) 3编制依据 (1) 4职责 (1) 5管理内容 (1) 6文件与记录 (4) 7附表 (4)

1目的 为加强对脚手架搭设、使用、拆除过程的控制与管理,降低高处作业风险,避免或减少坠落、坍塌、物体打击事故的发生,保证员工生命健康安全,特制定本规定。2适用范围 本规定适用于中煤陕西榆林能源化工有限公司煤化工项目建设期间建筑和安装工程使用的扣件式钢管脚手架的管理,组装式移动脚手架按制造厂家操作要求进行。3编制依据 《建筑安装工程安全技术规程》(国家建筑工程总局1980年5月20日); 《建筑施工扣件式钢管脚手架安全技术规范》(JGJ130-2001); 《石油化工施工安全技术规程》(SH3505-1999); 《危险性较大的分部分项工程安全管理办法》(建设部建质[2011]87号)。 4职责 4.1施工管理部组织对重大脚手架方案进行审查工作。 4.2项目组、监理单位对承包商脚手架搭设、使用、管理的全过程进行监督检查,项目HSE部负责对脚手架的管理进行监督。 4.3承包商相关人员职责 4.3.1承包商应确保选用有能力的持证架子工完成相关工作。 4.3.2脚手架使用方负责提出脚手架的使用要求,参与对脚手架的检查与验收,在使用过程中保持脚手架的完整性,严禁私自对脚手架进行拆改。 4.3.3专业技术人员负责编制脚手架施工方案,承包商的项目部负责方案的审批,属“危险性较大的分部分项工程”,必须按要求编制安全专项施工方案,如需组织专家组论证的方案,必须报业主HSE部备案,并组织搭设人员交底并签字。 4.3.4架子工应依照规范要求和脚手架施工方案进行搭设。 4.3.5承包商安全部门负责对脚手架组织验收、确认和挂牌,并对脚手架的使用、管理进行监督。 5管理内容 5.1脚手架材料的选用和储存 5.1.1脚手架钢管、扣件和连接件必须符合国家规范标准,并有材质合格证,在使用前由承包商专业人员进行检查确认,确保钢管无严重腐蚀、弯曲、压扁和裂缝,扣件和连接件无脆裂、变形和滑丝等缺陷。 5.1.2脚手板应采用钢、木材质;不得使用腐朽、破裂、大横透节的木脚手板,不得使用严重锈蚀、油污和裂纹的钢脚手板。钢、木脚手板不得混用,严禁使用竹脚手

脚手架搭设流程及要求

脚手架搭设流程及要求 一、落地式钢管脚手架工艺流程 落地脚手架搭设的工艺流程为:场地平整、夯实→基础承载力实验、材料配备→定位设置通长脚手板、底座→纵向扫地杆→立杆→横向扫地杆→小横杆→大横杆(搁栅)→剪刀撑→连墙件→铺脚手板→扎防护栏杆→扎安全网。 定距定位。根据构造要求在建筑物四角用尺量出内、外立杆离墙距离,并做好标记;用钢卷尺拉直,分出立杆位置,并用小竹片点出立杆标记;垫板、底座应准确地放在定位线上,垫板必须铺放平整,不得悬空。 在搭设首层脚手架过程中,沿四周每框架格内设一道斜支撑,拐角除双向增设,待该部位脚手架与主体结构的连墙件可靠拉接后方可拆除。当脚手架操作层高出连墙件两步时,宜先立外排,后立内排。其余按下构造要求搭设。 1、主杆基础 本工程脚手架基础利用基坑支护平台混凝土进行硬化,混凝土硬化厚度不小于10cm。地基承载能力能够满足外脚手架的搭设要求。

2、立杆间距 (1)脚手架立杆纵距1.5m,横距0.9m,步距1.8m;连墙杆间距竖直3.6m,水平4.5m(即两步三跨);里立杆距建筑物0.3m。 (2)脚手架的底部立杆采用不同长度的钢管参差布置,使钢管立杆的对接接头交错布置,高度方向相互错开500mm以上,且要求相邻接头不应在同步同跨内,以保证脚手架的整体性。 (3)立杆应设置垫木,并设置纵横方向扫地杆,连接于立脚点杆上,离底座20cm左右。 (4)立杆的垂直偏差应控制在不大于架高的1/400。 (5)立杆及纵横向水平杆构造要求: 3、大横杆、小横杆设置 (1)大横杆在脚手架高度方向的间距1.8m,以便立网挂设,大横杆置于立杆里面,每侧外伸长度为150mm。 (2)外架子按立杆与大横杆交点处设置小横杆,两端固定在立杆,以形成空间结构整体受力。 4、剪刀撑 脚手架外侧立面的两端各设置一道剪刀撑,并应由底至顶连续设置;中间各道剪刀撑之间的净距离不应大于15m。剪刀撑斜杆的接长宜采用搭接,搭接长度不小于1m,应采用不少于2个旋转扣件固定。剪刀撑斜杆应用旋转扣件固定在

脚手架作业管理规定

脚手架作业管理规 定 1

1 目的 为规范施工现场脚手架的管理,防止高处坠落事故的发生,保证员工人身安全,制定本规定。 2 适用范围 本规定适用于SFCC施工生产过程中脚手架的搭设、使用和拆除管理。 3 职责 3.1 项目管理部 3.1.1 负责对脚手架搭设专业队伍的评审和引进。 3.1.2 负责对脚手架专业分包队伍的管理。 3.2安全监督处 3.2.1 负责对脚手架专业搭设单位管理人员的培训。 3.2.2 负责对脚手架专业搭设单位的考核。 3.3项目部 3.3.1负责脚手架的验收、挂牌。 3.3.2负责脚手架监督人员和搭设人员的培训和考核。 3.3.3负责大型和特殊脚手架搭设、拆除方案的编制和审批。 3.3.4负责组织大型和特殊脚手架搭设前的技术交底。 3.4脚手架搭设单位 3.4.1负责按照使用方的要求编制大型和特殊脚手架搭设、拆除方案,并

按审批的方案进行脚手架搭设。 3.4.2脚手架搭设人员必须持有操作证,经过专门培训,并配备脚手架监督员。 3.4.3负责脚手架搭设过程的监督检查。 3.4.4 负责对脚手架搭设人员的日常培训和教育。 3.4.5 负责严格按照脚手架搭设的要求进行搭设。 3.4.6 负责配备合格的脚手架管理人员。 3.5脚手架的使用单位 3.5.1参加脚手架的验收。 3.5.2严格按照规范要求使用脚手架,不超载使用脚手架。 3.5.3负责对搭设方提出脚手架使用要求。 3.6脚手架监督员 3.6.1负责脚手架搭设过程的监督检查。 3.6.2负责脚手架搭设人员的培训。 3.6.3负责脚手架检查验收前的自检。 3.7脚手架检查员 3.7.1负责脚手架的验收挂牌。 3.7.2负责脚手架搭专业队伍人员的培训。 3.8脚手架搭设人员 3.8.1严格执行脚手架搭设管理规定,不得违章作业。 3.8.2严格按照脚手架方案要求搭设脚手架。 2

脚手架作业安全管理规定(正式)

编订:__________________ 单位:__________________ 时间:__________________ 脚手架作业安全管理规定 (正式) Standardize The Management Mechanism To Make The Personnel In The Organization Operate According To The Established Standards And Reach The Expected Level. Word格式 / 完整 / 可编辑

文件编号:KG-AO-8816-36 脚手架作业安全管理规定(正式) 使用备注:本文档可用在日常工作场景,通过对管理机制、管理原则、管理方法以及管理机构进行设置固定的规范,从而使得组织内人员按照既定标准、规范的要求进行操作,使日常工作或活动达到预期的水平。下载后就可自由编辑。 第一章总则 第一条为加强脚手架作业安全管理,防止事故发生,依据中国石油天然气集团公司《脚手架作业安全管理规范》(Q/SY1246-2009)制定本规定。 第二条本规定适用于中国石油天然气集团公司所属的炼油化工企业(以下简称炼化企业)以及为其服务的承包商。 第三条本规定规范了金属脚手架搭建、拆卸、移动和使用等作业的安全管理要求。 第四条名词解释 (一)技术负责人:指熟悉脚手架标准,经过脚手架搭设专业培训取得资格,能够识别脚手架作业中风险的人。 (二)作业人员:指经过脚手架搭设专业培训并

取得资格证,能进行脚手架搭设作业的人。 (三)脚手架:指一种临时搭建的、可供人员在其上施工、承载建筑物料的平台。 (四)斜道:指附着在脚手架或建筑物上、供人员行走和运送材料的通道,分为人行斜道和运料斜道。 第二章职责 第五条炼油与化工分公司组织制定、管理和维护本规定。 第六条炼化企业根据本规定制定、管理和维护本单位的脚手架作业安全管理实施细则,各相关职能部门具体负责本规定的执行并提供培训、监督与考核。 第七条炼化企业基层单位按要求执行本单位的脚手架作业安全管理实施细则,对本规定提出改进建议。 第三章管理要求 第一节基本要求 第八条脚手架搭设单位应具有相关资质,脚手架搭设人员应持有效的特种作业资格证。

11脚手架作业管理规定

1 目的 为规范施工现场脚手架的管理,防止高处坠落事故的发生,保证员工人身安全,制定本规定。 2 适用范围 本规定适用于SFCC施工生产过程中脚手架的搭设、使用和拆除管理。 3 职责 3.1 项目管理部 3.1.1 负责对脚手架搭设专业队伍的评审和引进。 3.1.2 负责对脚手架专业分包队伍的管理。 3.2安全监督处 3.2.1 负责对脚手架专业搭设单位管理人员的培训。 3.2.2 负责对脚手架专业搭设单位的考核。 3.3项目部 3.3.1负责脚手架的验收、挂牌。 3.3.2负责脚手架监督人员和搭设人员的培训和考核。 3.3.3负责大型和特殊脚手架搭设、拆除方案的编制和审批。 3.3.4负责组织大型和特殊脚手架搭设前的技术交底。 3.4脚手架搭设单位 3.4.1负责按照使用方的要求编制大型和特殊脚手架搭设、拆除方案,并按审批的方案进行脚手架搭设。 3.4.2脚手架搭设人员必须持有操作证,经过专门培训,并配备脚手架监督员。 3.4.3负责脚手架搭设过程的监督检查。 3.4.4 负责对脚手架搭设人员的日常培训和教育。 3.4.5 负责严格按照脚手架搭设的要求进行搭设。 3.4.6 负责配备合格的脚手架管理人员。 3.5脚手架的使用单位 3.5.1参加脚手架的验收。 3.5.2严格按照规范要求使用脚手架,不超载使用脚手架。

3.5.3负责对搭设方提出脚手架使用要求。 3.6脚手架监督员 3.6.1负责脚手架搭设过程的监督检查。 3.6.2负责脚手架搭设人员的培训。 3.6.3负责脚手架检查验收前的自检。 3.7脚手架检查员 3.7.1负责脚手架的验收挂牌。 3.7.2负责脚手架搭专业队伍人员的培训。 3.8脚手架搭设人员 3.8.1严格执行脚手架搭设管理规定,不得违章作业。 3.8.2严格按照脚手架方案要求搭设脚手架。 4 工作程序 4.1 人员配备 4.1.1脚手架施工单位至少配备一名脚手架搭设、拆除作业监督员,要求从事脚手架搭设3年以上。 4.1.2项目部必须配备一名脚手架搭设检查员,要求熟悉脚手架搭设、验收规范,并接受过脚手架专业培训。 4.2脚手架材料的选用 4.2.1钢管 1)脚手架搭设之前,作业人员应对所用钢管材料进行检查,确认合格后方可使用。如有严重腐蚀、弯曲、压扁和裂缝情况者禁止使用; 2) 钢管应选用外径48~51mm,壁厚为3~3.5mm的钢管,质量符合应符合《碳素结构钢》(GB/T700)中Q235-A级钢的规定。 4.2.2脚手板 1) 木脚手板应使用厚度不小于50毫米、宽度为200~300毫米、长度不大于6米的坚韧木板,两端用4mm的铁丝箍两道;不得使用腐朽、破裂、大横透节的木板作脚手板。 2) 钢脚手板不得有严重锈蚀、油污和裂纹,并有防滑措施。 4.2.3扣件 1)扣件和连接件有脆裂、变形和滑丝等缺陷。 4.2.4其他材料

脚手架的搭设流程及要求

行业资料:________ 脚手架的搭设流程及要求 单位:______________________ 部门:______________________ 日期:______年_____月_____日 第1 页共7 页

脚手架的搭设流程及要求 落地脚手架搭设的工艺流程为:场地平整、夯实基础承载力实验、材料配备定位设置通长脚手板、底座纵向扫地杆立杆横向扫地杆小横杆大横杆(搁栅)剪刀撑连墙件铺脚手板扎防护栏杆扎安全网。 定距定位。根据构造要求在建筑物四角用尺量出内、外立杆离墙距离,并做好标记;用钢卷尺拉直,分出立杆位置,并用小竹片点出立杆标记;垫板、底座应准确地放在定位线上,垫板必须铺放平整,不得悬空。 在搭设首层脚手架过程中,沿四周每框架格内设一道斜支撑,拐角除双向增设,待该部位脚手架与主体结构的连墙件可靠拉接后方可拆除。当脚手架操作层高出连墙件两步时,宜先立外排,后立内排。其余按一下构造要求搭设。 1、主杆基础 本工程脚手架地基础部位应在回填土完后夯实,采用强度等级不低于C15的混凝土进行硬化,混凝土硬化厚度不小于10cm。地基承载能力能够满足外脚手架的搭设要求(具体计算数据参阅脚手架计算书)。 2、立杆间距 (1)脚手架立杆纵距1.5m,横距1.05m,步距1.8m;连墙杆间距竖直3.6m,水平4.5m(即二步三跨):里立杆距建筑物0.3m。 (2)脚手架的底部立杆采用不同长度的钢管参差布置,使钢管立杆的对接接头交错布置,高度方向相互错开500mm以上,且要求相邻接头不应在同步同跨内,以保证脚手架的整体性。 (3)立杆应设置垫木,并设置纵横方向扫地杆,连接于立脚点杆上, 第 2 页共 7 页

脚手架作业标准20110701

Q/SY WH4248—2011 脚手架作业管理标准 1 范围 本标准规定了乌鲁木齐石化公司范围内脚手架和吊篮的搭设、拆卸、移动、使用的管理内容与要求,检查与考核。 本标准适用于乌鲁木齐石化公司范围内用脚手架作业和吊篮作业管理。 2 引用标准及定义 2.1引用标准 JGJ 128-2010《建筑施工门式钢管脚手架安全技术规范》 JGJ 130-2001《扣件式钢管脚手架安全技术规范》 JG5027-92《高处作业吊篮安全规则》 国家安全生产监督管理总局令第30号《特种作业人员安全技术培训考核管理规定》 Q/SY1246-2009中国石油天然气集团公司《脚手架作业安全管理规范》 中国石油天然气股份有限公司炼化分公司油炼化[2011]11号文《关于印发十六项健康安全环保(HSE)管理规定的通知》 2.2定义 2.2.1脚手架:脚手架是一种临时搭建的可供人员在其上施工、承载建筑设备和物料的平台。 2.2.2斜道:附着在脚手架或建筑物上供人员行走和运送材料用的通道,分为人行斜道和运料斜道。 2.2.3吊篮:吊篮是建筑工程高空作业的建筑机械,运送人上下的篮状装置。 3 职责 3.1 公司机动处为本标准的归口管理部门,负责制订和修订本标准及对本标准执行情况进行检查与考核,对搭设脚手架作业单位的资质进行审核。 3.2 公司安全环保处为脚手架作业的安全管理部门,对搭设脚手架作业单位和人员安全资质审核,并对作业、使用进行安全监督。 3.3各二级单位负责本单位管辖范围内脚手架的搭设、验收、使用、拆除进行具体管理。 4 管理内容与要求 4.1基本要求 4.1.1所有从事脚手架和吊篮搭设的作业单位必须具有相应资质。从事脚手架及吊篮搭设、拆除作业的人员应进行培训并按照国家安全生产监督管理总局《特种作业人员安全技术培训考核管理规定》规定取得主管部门颁发的建筑登高架设作业特种工作业资格证书。作业前属地单位须对作业人员持证情况进行确认。 4.1.2脚手架作业人员健康条件应符合高处安全作业管理的相关要求。患有心脏病、高血压、癫痫以及感冒、患病期间服用含有影响精神和判断力药品的人员不得进行脚手架或吊篮作业。 ___________________________________________________________________ _______________ 乌鲁木齐石化公司2011-06-25发布2011-07-01实施

脚手架安全管理规范

一、目的 为加强脚手架安全管理,预防和减少事故的发生,特制定本规定。 本规定适用于项目所有参建单位。 二、定义 三、职责: 1、公司各部门对职责范围内的HSE工作负责,HSE部对各部门的HSE工作开展进行监督。 2、监理机构按公司要求对施工现场和承包商的HSE工作进行监督、检查。 3、承包商对工作范围内的HSE工作负责,应严格执行项目HSE要求和相关标准规范,并接受公司和监理机构的监督、管理。 四、管理要求 1、凡有脚手架作业,承包商应建立脚手架管理程序,提交监理机构和公司审批,并组织实施。 2、承包商应根据相关标准、规范的要求编制脚手架搭设和拆除的施工方案,经承包商项目负责人审核,并获监理机构或公司审查批准。 大型和承重脚手架的搭设方案中必须要有稳定性验算和风险评估;大型脚手架、高度超过30m的脚手架应设置逃生通道;高度超过20米,且预计使用时间涉及雷雨季节的脚手架应考虑避雷设施。 3、承包商应使用扣件式钢管脚手架,若使用其他类型的脚手架(如门式钢管脚手架、碗扣式脚手架等)必须事先获得监理机构和公司批准。 4、脚手架的搭设、拆除属于高处作业,承包商需要遵守项目《高处作业安全管理规定》,申办《高处作业许可证》。

5、资质 (1)承包商应任命一名有资质的、足够经验的脚手架施工负责人,报监理机构和公司批准,并将资质证明存档。 (2)搭设或拆除脚手架必须由专业架子工担任,持证上岗;上岗人员应定期体检,凡不适于高处作业者,不得上脚手架作业。 6、培训和安全交底 (1)承包商须为脚手架搭设、拆除和使用人员进行专项安全培训,培训内容包括但不限于:坠落保护、脚手架使用、电气危险等。 (2)脚手架搭设或拆除作业前,承包商应根据施工方案对搭设和拆除人员进行安全技术交底,让施工人员了解施工环境、安全要求及应急措施。 7、承包商和监理机构应按施工方案的要求对脚手架材料进行检查、验收,脚手架材料均应有有效的质量证明文件,不合格产品严禁使用。 (1)本项目严禁使用竹制和木制脚手架。 (2)脚手架应选用外径48~51mm,壁厚为3~3.5mm的焊接钢管;钢管应平直、两端面平整,不得有斜口、毛口;严禁使用硬弯、压扁和裂缝及严重锈蚀等的钢管;严禁将外径48mm与51mm的钢管混合使用。 (3)垫板应采用长度不少于2跨、厚度不小于50mm的木垫板,也可采用槽钢。 (4)脚手板可用木脚手板或钢脚手板,不得使用竹脚手板和其他材质的脚手板。使用木脚手板的宽度不小于200mm,厚度不小于50mm,任何腐朽、虫蛀、有裂纹的脚手板不得在本项目上使用;钢脚手板不得有严重锈蚀、油污、裂纹和较大变形。 (5)扣件规格必须与钢管外径相同;严禁使用有脆裂、气孔、变形和滑丝等缺陷的扣件、连接件和底座等材料;捆绑脚手板用的镀锌铁丝宜为8号铁丝。 8、脚手架搭设

脚手架安全管理规定(通用版)

( 安全管理 ) 单位:_________________________ 姓名:_________________________ 日期:_________________________ 精品文档 / Word文档 / 文字可改 脚手架安全管理规定(通用版) Safety management is an important part of production management. Safety and production are in the implementation process

脚手架安全管理规定(通用版) 为了加强对脚手架施工全过程的控制和管理,进一步规范脚手架的搭设、拆除,材料的验收及使用中的各项安全管理要求,强化对危险性较大和特殊脚手架施工过程的安全管理,有效控制安全生产事故,最大限度地保障操作工人的人身安全,减少企业风险,特制定本规定。 一、适用范围: 本规定适用公司所属各单位和施工现场(含联营和各种形式承包的工程项目部)。 二、编制依据: 1、《建筑施工高处作业安全技术规范》JGJ80-91 2、《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2001 3、《安全网》GB5725---1997 4、《密目式安全立网》GB16909---1997

5、《北京市建设工程施工现场安全防护标准》 6、《建筑施工安全检查标准》JGJ59-99 7、北京市建筑工程总公司《脚手架安全技术操作规程》 8、《北京建工集团施工现场创建达标管理办法》 9、《三建公司文明施工达标执行标准》 三、脚手架安全管理要求: (一)材料、材质的安全管理要求: 1、钢管: 脚手架钢管应采用《直缝电焊钢管》或《低压流体输送用焊接钢管》。钢管应采用:外径48-51mm,壁厚3.0-3.5mm,长度为4-6m 和2.1-2.3m,每根钢管的最大质量不应大于25kg的钢管。钢管必须做防锈处理,并涂桔黄色油漆。 2、扣件: 扣件应采用可锻铸铁制作的扣件,规格必须与钢管外径尺寸相同,扣件无论新旧均应进行防锈处理,直角扣件自重应为13.2N/个、旋转扣件自重应为14.6N/个、对接扣件自重应为18.4N/个。

钢管脚手架搭设流程要求(5)

钢管脚手架搭设流程要求(5) 钢管脚手架搭设流程及要求(五) 工艺流程: 落地脚手架搭设的工艺流程为:场地平整、夯实浇筑垫层→基础承载力实验、材料配备→定位设置通长脚手板、底座→纵向扫地杆→立杆→横向扫地杆→小横杆→大横杆(搁栅)→剪刀撑→连墙件→铺脚手板→扎防护栏杆→扎安全网。 定距定位。根据构造要求在建筑物四角用尺量出内、外立杆离墙距离,并做好标记;用钢卷尺拉直,分出立杆位置,并用小竹片点出立杆标记;垫板、底座应准确地放在定位线上,垫板必须铺放平整,不得悬空。在搭设首层脚手架过程中,沿四周每框架格内设一道斜支撑,拐角除双向增设,待该部位脚手架与主体结构的连墙件可靠拉接后方可拆除。当脚手架操作层高出连墙件两步时,宜先立外排,后立内排。其余按一下构造要求搭设。 1、主杆基础 本工程脚手架地基础部位应在回填土完后夯实,采用强度等级不低于C15的混凝土进行硬化,混凝土硬化厚度不小于10cm,地基承载能力能够满足外脚手架的搭设要求(具体计算数据参阅脚手架计算书)。 2、立杆间距 (1)脚手架立杆纵距1.5m,横距1.05m,步距1.8m;连墙杆间距竖直3.6m,水平4.5m(即两步三跨);内立杆距建筑物0.3m。 (2)脚手架的底部立杆采用不同长度的钢管参差布置,使钢管立杆的对接接头交错布置,高度方向相互错开500mm以上,且要求相邻接头不应在同步同跨内,以保证脚手架的整体性。 (3)立杆应设置垫木并设置纵横方向扫地杆,连接于立脚点杆上,离底座20cm左右。 (4)立杆的垂直偏差应控制在不大于架高的1/400。 (5)立杆及纵横向水平杆构造要求: 3、大横杆、小横杆设置 (1)大横杆在脚手架高度方向的间距1.8m,以便立网挂设,大横杆置于立杆里面,每侧外伸长度为150mm。 (2)外架子按立杆与大横杆交点处设置小横杆,两端固定在立杆,以形成空间结构整体受力。 4、剪刀撑 搭设高度24m以上脚手架,剪刀撑应在外侧立面长度和高度方向上连续设置。剪刀撑斜杆的接长宜采用搭接,搭接长度不小于1m,应采用不少于2个旋转扣件固定。剪刀撑斜杆应用旋转扣件固定在与之相交的横向水平杆的伸出端或立杆上,旋转扣件中心线离主节点的距离不宜大于150mm。 5、脚手板、脚手片的铺设要求 (1)脚手架里排立杆与结构层之间均应铺设木板:板宽为200mm,里外立杆间应满铺脚手板,无探头板。 (2)满铺层脚手片必须垂直墙面横向铺设,满铺到位,不留空位,不能满铺处必须采取有效的防护措施。 (3)脚手片须用12-14#铅丝双股并联绑扎,不少于4点,要求绑扎牢固,交接处平整,铺设时要选用完好无损的脚手片,发现有破损的要及时更换。 6、防护栏杆 (1)脚手架外侧使用建设主管部门认证的合格绿色密目式安全网封闭,且将安全网固定

脚手架作业安全管理实施细则(最新版)

When the lives of employees or national property are endangered, production activities are stopped to rectify and eliminate dangerous factors. (安全管理) 单位:___________________ 姓名:___________________ 日期:___________________ 脚手架作业安全管理实施细则 (最新版)

脚手架作业安全管理实施细则(最新版)导语:生产有了安全保障,才能持续、稳定发展。生产活动中事故层出不穷,生产势必陷于混乱、甚至瘫痪状态。当生产与安全发生矛盾、危及职工生命或国家财产时,生产活动停下来整治、消除危险因素以后,生产形势会变得更好。"安全第一" 的提法,决非把安全摆到生产之上;忽视安全自然是一种错误。 第一章总则 第一条为规范长庆油田分公司水电厂(以下简称水电厂)所辖生产生活区域等施工作业中的有关脚手架作业的安全管理,防止脚手架坍塌、高处坠落等事故的发生,依据《长庆油田分公司脚手架作业安全管理办法》以及国家相关法律法规、技术规范标准等,特制定本细则。 第二条脚手架是一种临时搭设的、可供人员在其上施工、承载建筑、设备和物料的平台。 第三条本细则适用于水电厂所属各单位(包括厂监管的多元经济单位)及承揽水电厂施工任务承包商的任何金属(木)脚手架作业活动,包括搭建、拆卸、移动、提升、改建和使用脚手架作业。 第二章脚手架作业管理要求 第四条脚手架作业实行作业许可制度,应办理作业许可手续(应有许可票见附件),并详细说明作业范围、确定危害和评估风险、制

脚手架安全管理制度通用版

管理制度编号:YTO-FS-PD507 脚手架安全管理制度通用版 In Order T o Standardize The Management Of Daily Behavior, The Activities And T asks Are Controlled By The Determined Terms, So As T o Achieve The Effect Of Safe Production And Reduce Hidden Dangers. 标准/ 权威/ 规范/ 实用 Authoritative And Practical Standards

脚手架安全管理制度通用版 使用提示:本管理制度文件可用于工作中为规范日常行为与作业运行过程的管理,通过对确定的条款对活动和任务实施控制,使活动和任务在受控状态,从而达到安全生产和减少隐患的效果。文件下载后可定制修改,请根据实际需要进行调整和使用。 第一条因工作需要,在施工现场所搭设了型态各异的脚手架,目的是满足工作人员高处安全作业,顺利完成施工任务。搭设脚手架的专业人员、凡上脚手架施工的人员,除务必熟悉遵守:《热机安规》第十三章、《电力建设安全工作规程》火力发电厂部分第七章的有关规定外,广大施工、搭设架子的专业人员都必须遵守本制度。 第二条搭设脚手架的专业人员,必须经医生进行体检,无不宜登高作业的病况。必须经过专业培训,经安规考试合格后,方可上岗作业。 第三条进入施工现场必须佩戴安全帽,搭设脚手架必须严格遵守《安规》、《电力建设安全工作规程》中的有关规定,专业人员搭设前必须对所用材料进行详细检查,凡弯曲、枯脆、白麻、虫蛀的竹片脚手板,严禁使用。 第四条搭设特殊形式的脚手架或超重脚手架必须经有关领导或技术人员编写措施经批准后方可实施。 第五条脚手架搭设后,施工负责人与搭设脚手架负

脚手架搭设安全管理规定

编号:SM-ZD-18837 脚手架搭设安全管理规定Through the process agreement to achieve a unified action policy for different people, so as to coordinate action, reduce blindness, and make the work orderly. 编制:____________________ 审核:____________________ 批准:____________________ 本文档下载后可任意修改

脚手架搭设安全管理规定 简介:该制度资料适用于公司或组织通过程序化、标准化的流程约定,达成上下级或不同的人员之间形成统一的行动方针,从而协调行动,增强主动性,减少盲目性,使工作有条不紊地进行。文档可直接下载或修改,使用时请详细阅读内容。 1 目的 为规范脚手架搭设、拆除工作,确保施工人员在脚手架上工作的安全,特制定本规定。 2 适用范围 本厂造、修船、分段施工脚手架搭设工作。 3 搭设材料 3.1.1 钢管应用外径48—51mm,壁厚3— 4.5mm钢管,有严重锈蚀、弯曲、压扁或裂纹的不得使用。 3.1.2 扣件应与钢管配套,应有出厂合格证。发现有脆裂、变形、滑丝的不得使用。 3.1.3 木脚手板应使用厚度不小于50mm,宽度不小于220mm的松木板制成。凡腐朽、扭曲、斜纹、破裂、大横透节和容易折断的不得使用。 3.1.4 钢脚手板要有足够的强度和刚度,凡是裂纹、破损、扭曲的不得使用。

3.1.5 挂跳用麻绳应用直径14-16mm的棕麻绳,凡腐朽、霉烂、多处绳结的不准使用。 4.搭设规定 4.1 搭设脚手架要有足够的强度,应有较好的稳定性,必须保证安全。要有保证人员好上下脚手架的设施及脚手架上要有足够的工作面,保证人员在脚手架上好施工。 4.2 钢管扣件式脚手架 4.2.1 双排脚手架立杆间距为2.5m,因条件限制,最大间距不得超过3m。超过20m高的脚手架,每间隔一根立杆需用双根钢管做立杆,底部立杆应用长短不同的钢管架设,以避免接头在同一水平线上。 4.2.2 大横杆底层高为2m,以上每层高为1.8米,舱内每步高度根据实际情况搭设,但每层高不得超过2米。大横杆三层之内应设临时斜撑,三层以上应设固定斜撑,如不好设置须设拉撑,拉撑为每三层,立撑为三根间距设置一个。船体外壳四周已连接的脚手架可以不设斜撑和拉撑。 4.2.3 横杆伸出大横杆的距离不得大于300mm,若超出时应加斜撑方可搁置脚手板。

钢管脚手架搭设流程要求(5)

工作行为规范系列 钢管脚手架搭设流程要求 (5) (标准、完整、实用、可修改)

编号:FS-QG-81457钢管脚手架搭设流程要求(5)Requirements for erection of steel pipe scaffolding 说明:为规范化、制度化和统一化作业行为,使人员管理工作有章可循,提高工作效率和责任感、归属感,特此编写。 钢管脚手架搭设流程及要求(五) 工艺流程: 落地脚手架搭设的工艺流程为:场地平整、夯实浇筑垫层→基础承载力实验、材料配备→定位设置通长脚手板、底座→纵向扫地杆→立杆→横向扫地杆→小横杆→大横杆(搁栅)→剪刀撑→连墙件→铺脚手板→扎防护栏杆→扎安全网。 定距定位。根据构造要求在建筑物四角用尺量出内、外立杆离墙距离,并做好标记;用钢卷尺拉直,分出立杆位置,并用小竹片点出立杆标记;垫板、底座应准确地放在定位线上,垫板必须铺放平整,不得悬空。在搭设首层脚手架过程中,沿四周每框架格内设一道斜支撑,拐角除双向增设,待该部位脚手架与主体结构的连墙件可靠拉接后方可拆除。当脚手架操作层高出连墙件两步时,宜先立外排,后立内排。

其余按一下构造要求搭设。 1、主杆基础 本工程脚手架地基础部位应在回填土完后夯实,采用强度等级不低于C15的混凝土进行硬化,混凝土硬化厚度不小于10cm,地基承载能力能够满足外脚手架的搭设要求(具体计算数据参阅脚手架计算书)。 2、立杆间距 (1)脚手架立杆纵距1.5m,横距1.05m,步距1.8m;连墙杆间距竖直3.6m,水平4.5m(即两步三跨);内立杆距建筑物0.3m。 (2)脚手架的底部立杆采用不同长度的钢管参差布置,使钢管立杆的对接接头交错布置,高度方向相互错开500mm 以上,且要求相邻接头不应在同步同跨内,以保证脚手架的整体性。 (3)立杆应设置垫木并设置纵横方向扫地杆,连接于立脚点杆上,离底座20cm左右。 (4)立杆的垂直偏差应控制在不大于架高的1/400。 (5)立杆及纵横向水平杆构造要求:

脚手架搭设使用管理规定

脚手架搭设使用管理规定 第一章总则 第一条为规范神东电力店塔发电公司所属各部门生产现场脚手架的搭设和使用管理工作,保证使用过程中的人员和设备安全,根据《电业安全工作规程(热力和机械部分)》和《电力建设安全工作规程第1 部分:火力发电厂》等法规,特制定本规定。 第二条本规定适用于店塔发电公司范围内的设备检修、维护、调试,小型基建工程施工所需搭设的脚手架。 第二章职责 第一条安全分管负责人 (一)负责组织、指导本单位安全监察部落实本规定; (二)负责审查本单位安全监察部提交的规定改进建议报告。 第二条安全监察部 (一)负责本规定的编制和修订并确保本规定的适用性; (二)监督各单位认真贯彻、落实本规定; (三)定期到各部门检查、指导现场安全工作; (四)负责检查本规定在本单位的执行情况,定期将执行情况反馈安全分管负责人及公司安全监察部。 第三条各使用部门 (一)负责对各自所管辖设备区域搭设的脚手架日常安全检查和管理工作,是脚手的归口管理部门,妥善管理厂内的脚手架,加强对脚手架承包单位的管理,监督检查脚手架搭设的质量。负责建立脚手架日常使用状况记录。及时向安全监察部报告发生的问题或反馈有关信息;

(二)认真组织并贯彻执行本规定,将执行情况提出自查评价意见,做出处理,报安全监察部。 第四条承包脚手架搭设单位 严格执行《外委工程管理办法》中的相关规定。严格执行承包合同及安全协议中的相关规定。确保每次脚手架的搭设与拆除及检修过程的安全顺利的完成。 第三章脚手架的搭设和使用程序 第五条脚手架搭设的基本要求 (一)脚手架荷重一般只承受工作人员和放置小型器具,总重量不能超过 270kg/ m2;搭设好的脚手架应经搭设部门和使用部门验收合格后方可交付使用。使用中应定期检查和维护; (二)荷重超过270kg/ m2的脚手架应进行设计,并经技术负责人批准后方可搭设; (三)在构筑物上搭设脚手架应验算构筑物的强度; (四)非专业工种人员不得搭、拆脚手架。搭设脚手架时作业人员应挂好安全带,递杆、撑杆作业人员应密切配合。施工区周围应设围栏或警告标志,并由专人监护,严禁无关人员入内; (五)脚手架的立杆应垂直。钢管立杆应设置垫板或金属底座。木杆应埋入地下30?50mm,杆坑底部应夯实并垫以砖石;遇松土或无法挖坑时应绑扫地杆。横杆应平行与立杆成直角搭设;小横杆应设置在横杆上; (六)各种材质脚手架的立杆、大横杆及小横杆的间距不得大于表1 的规定

相关主题