当前位置:文档之家› 长沙市岳麓办公大厦空调系统计算说明书

长沙市岳麓办公大厦空调系统计算说明书

长沙市岳麓办公大厦空调系统计算说明书
长沙市岳麓办公大厦空调系统计算说明书

空调说明书分析解析.doc

Hot water heat pump installation instructions Thank you for using our Zhigao central air conditioners. This instruction book is a general version of heat pump hot water machine from Zhigao. The appearance of machine that you buy may be different from the instruction book we described. But it doesn’t matter for your operations. Before you use it, please read the instruction book carefully and take care of it The product you are using is air heat pump and water heater of Zhigao, it needs cleaning and maintaining periodically. If it is not done, the rate of breaking down would increase, and its life would reduce seriously; while if cleaned reasonably, the internal dust would be eliminated as result of improving indoor air quality, and reducing the power consumption. To protect your legal rights, please install by qualified workers. . The product you are using is heat pump and water heater of Zhigao. If it operates within a short time in winter, make sure charge for 24 hours a day; if not operates for a long time, be sure to draw off water in it, avoiding the unit’s cracking. Please contact with central air-conditioning management system center, Zhigao regularly, professionals will be sent with paying for checking, draining, adding water, adjustment and other cleaning and maintenance services. Just in case, air conditioner fails down.

暖通空调设计毕业设计说明书

摘要 本设计为哈尔滨望江集团办公楼空调系统工程设计。哈尔滨望江集团办公楼属中小型办公建筑,本建筑总建筑面积4138m2,空调面积2833m2。地下一层,地上八层,建筑高度33.9m。全楼冷负荷为191千瓦,全楼采用水冷机组进行集中供给空调方式。 此设计中的建筑主要房间为办公室,大多面积较小,且各房间互不连通,应使所选空调系统能够实现对各个房间的独立控制,综合考虑各方面因素,确定选用风机盘管加新风系统。在房间内布置吊顶的风机盘管,采用暗装的形式。将该集中系统设为风机盘管加独立新风系统,新风机组从室外引入新风处理到室内空气焓值,不承担室内负荷。风机盘管承担室内全部冷负荷及部分的新风湿负荷。风机盘管加独立新风系统由百叶风口下送和侧送。水系统采用闭式双管同程式,冷水泵三台,两用一备;冷却水泵选三台,两用一备。 在冷负荷计算的基础上完成主机和风机盘管的选型,并通过风量、水量的计算确定风管路和水管路的规格,并校核最不利环路的阻力和压头用以确定新风机和水泵。 依据相关的空调设计手册所提供的参数,进一步完成新风机组、水泵、热水机组等的选型,从而将其反应在图纸上,最终完成整个空调系统设计。 关键词:风机盘管加独立新风系统;负荷;管路设计;制冷机组:冷水机组

Abstract The design for the Harbin Wangjiang Design Group office building air conditioning system. Harbin Wangjiang Group is a small and medium-sized office building office buildings, the total floor area of building is 4138m2, air-conditioned area is 2833m2. There are eight floor of the building, building height is 33.9m. Cooling load for the entire floor, 191 kilowatts, the whole floor using Central Cooling Chillers to focus on the way . This design of the main room of the building for office, most of them is very small, and the rooms are not connected, the selected air-conditioning system should be able to achieve independent control of each room, considering the various factors to determine the selection of fan-coil plus fresh air system. Arrangement in the room ceiling fan coil units, using the dark form of equipment. Set the focus on fan-coil system, plus an independent air system, fresh air from the outdoor unit to deal with the introduction of a new wind to the indoor air enthalpy value, do not bear the load of indoor. All bear the indoor fan-coil cooling load and part of its new rheumatoid load. Fan-coil plus an independent air system sent by the Venetian and the under side air delivery. Closed water system with a dual-track program, three cold-water pump, dual-use a prepared; cooling pumps three elections, one prepared by dual-use. In the cooling load calculation based on the completion of the selection of host and fan coil units, and air volume, the calculation of water, the wind pipe and water pipes to determine the specifications of the road and check the resistance to the most disadvantaged and the loop to determine the pressure head new fans and pumps. Based on the relevant manuals provided by air-conditioning design parameters, and further completion of the new air units, water pumps, hot water units, such as the selection, which will be reflected in their drawings, the final design of the entire air-conditioning system Key words: PAU+FCU systems; load; pipeline design; refrigeration machine; Chillers

家用空调设计计算说明书

制冷系统课程设计说明书 热能与动力工程专业 目录 一、 设计工况 ............................................ 3 二、 压缩机选型 .......................................... 3 三、 热力计算 ............................................ 5 1、循环工况: ......................................... 5 2、 热力计算: ........................................ 6 四、蒸发器设计计算 (7)

1、设计工况: (7) 2、计算过程: (8) 3、风机的选择 (18) 4、汇总 (18) 五、冷凝器换热计算 (19) 第一部分:设计计算 (19) 一、设计计算流程图 (19) 二、设计计算 (19) 3、计算输出 (25) 第二部分:校核计算 (25) 一、校核计算流程图 (25) 二、计算过程 (26) 六、节流装置的估算和选配 (27) 七、空调电器系统 (28)

一、设计工况 3KW机组,半封闭压缩机,风冷冷凝器,风冷蒸发器,毛细管,制冷剂R22,蒸发温度5℃,过热度20℃,冷凝温度50℃,过冷度5℃ 二、压缩机选型 1、选型条件:制冷量3kW,制冷剂R22,蒸发温度5℃,过热度20℃,冷凝温度50℃,过冷度5℃。 2、选型结果:使用压缩机选型软件select 6,选择型号为DKM-75的半封闭往复式压缩机。 a.其基本参数如下:制冷量3.15kW,输入功率1.06kW,cop为 2.97,电流(400V)2A,质量流量18.9g/s,放热 3.65kWb. b.其技术参数:

空调系统热负荷计算说明书

编号:XXXXXXXX 空调系统热负荷计算 编制: 校队: 审核: 批准:

目录

一、概述 为了消除车室内多余热量以维持温度恒定,所需要向车室内供应的冷量称为冷负荷。为了消除车室内多余湿量以维持车室内相对湿度恒定,所需除去的湿量称为湿负荷。汽车空调热湿负荷的计算,是确定送风量和正确选者空调装置的依据。 二、空调系统冷负荷计算 本系统设计主要是估算冷负荷,以便压缩机的选配和两器的设计,本设计中主要是针对压缩机的选配,我们采用较容易确定的太阳辐射热QS和玻璃渗入热QG,他们的总合占系统的70%。即可得总负荷,为了安全再取k=1.05的修正系数。 2.1轿车一般的工况条件: 冷凝温度tc=63°,蒸发温度te=0°,膨胀阀前制冷剂过冷温度△tsc =5°,蒸发器出口制冷剂气体过热度△tsh=5,压缩机吸气温度 ts=10°,室外温度ti=35°,室内温度t0=27°,轿车正常行驶速度 ve=40km/h ,压缩机正常转速n=1800r/min. 2.2太阳辐射热的确定 由于太阳照射,汽车车身温度升高,在温差的作用下,热量以导热方式传如车室内,太阳辐射是由直射或散射辐射构成,车体外表面由于太阳辐射而提高了温度,同时向外反射辐射热,因此,车体外表面所受的辐射强度按下式计算:Q1=(IG+IS-IV)F= (IG+IS)F 其中ε——表面吸收系数,深色车体取=0.9,浅色车体取=0.4; IG——太阳直射辐射强度,取IG=1000W/m2 IS——太阳散射辐射强度,取IS=40W/m2 IV——车体表面反射辐射强度,单位为W/m2 F——车体外表面积,单位为m2,实测F=1.2m2 可将太阳辐射强度化成相当的温度形式,与室外空气温度叠加在一起,构成太阳辐射表面的综合温度tm。对车身结构由太阳辐射和照射热对流换热两部分热量组成: Qt=[a(tm-t0)+(tm-ti)]*F 式中:Qt——太阳辐射及太阳照射得热量,单位为W; a——室外空气与日照表面对流放热系数,单位为W/m2K tm——日照表面的综和温度,单位为°C。 K——车体围护结构对室内的传热系数,单位为W/m2K; to——车室外设计温度,取为35°C。 ti——车室内设计温度,取为27°C。 应采用对流换热推测式求解,但是由于车速变化范围大,车身外表面复杂,难以精确计算,一般采用近似计算公式: =1.163(4 +12 ) Wc是汽车行驶速度,可以采用40km/h计算: 代入上式得: a=51.15W/(m2k) 取K=4.8 W /(㎡?K), ε=0.9,I= IG+IS=1040 W, 因为= 所以: tm= +

综合办公楼空调系统设计说明书

综合办公楼空调系统设 计说明书 空调系统 过去 50 年以来,空调得到了快速的发展,从曾经的奢侈品发展到可应用于大多 数住宅和商业建筑的比较标准的系统。在 1970 年的美国, 36% 的住宅不是全空气调节就是利用一个房间空调器冷却;到1997年,这一数字达到了 77%,在那年作的第一 次市场调查表明,在美国有超过一半的住宅安装了中央空调 (人口普查局, 1999)。在1998年,83%的新建住宅安装了中央空调 ( 人口普查局, 1999)。中央空调在商业建筑物中也得到了快速的发展,从 1970年到1995年,有空调的商业建筑物的百分比从54% 增加到 73%(杰克森和詹森,1978)。 建筑物中的空气调节通常是利用机械设备或热交换设备完成.在大多数应用中,建筑物中的空调器为维持舒适要求必须既能制冷又能除湿,空调系统也用于其他的场所,例如汽车、卡车、飞机、船和工业设备,然而,在本章中,仅说明空调在商业和住宅 建筑中的应用。 商业的建筑物从比较大的多层的办公大楼到街角的便利商店,占地面积和类型差 别很大,因此应用于这类建筑的设备类型比较多样,对于比较大型的建筑物,空调设 备设计是总系统设计的一部分,这部分包括如下项目:例如一个管道系统设计,空气 分配系统设计,和冷却塔设计等。这些系统的正确设计需要一个有资质的工程师才能 完成。居住的建筑物(即研究对象)被划分成单独的家庭或共有式公寓,应用于这些 建筑物的冷却设备通常都是标准化组装的,由空调厂家进行设计尺寸和安装。 本章节首先对蒸汽压缩制冷循环作一个概述,接着介绍制冷剂及制冷剂的选择,最后介绍冷水机组。 1.1 蒸汽压缩循环

空调配置方案设计原理及计算方法

三、空调配置方案设计原理及计算方法 工程冷负荷计算方法采用目前应用较多、以传递函数法为基础、通过研究和实验而得到的冷负荷系数法。其中内维护结构按稳态传热计算。 二、维护结构冷负荷 维护结构冷负荷,可以分为外维护结构和内维护结构两部分 (一)、外维护结构冷负荷 1、外窗冷负荷 外窗冷负荷由两部分构成,即太阳辐射得热引起的冷负荷和温差传热引起的冷负荷。(1)、太阳辐射得热通过玻璃引起的逐时冷负荷按下式计算: CL=Ca ·Cs ·Cn ·Fc ·Djmax ·Ccl (W )(1) 式中Ca——窗有效面积系数; Cs——窗玻璃遮挡系数; Cn——窗内遮阳系数; Fc——外窗面积(m2); Djmax——最大太阳辐射得热因素(W); Ccl——外窗冷负荷系数。 (2)温差传热通过玻璃窗引起的逐时冷负荷按下式计算: CL=kc·KC ·Fc ·(t1+td–tns) (W )(2) 式中kc——外窗传热系数修正值; KC——外窗夏季传热系数[W/(m2·℃)]; Fc——外窗面积(m2); t1——外窗冷负荷计算温度(℃); td——外窗冷负荷计算温度地点修正值(℃); tns——夏季室内设计温度(℃); 2、外墙及屋面冷负荷 温差传热通过外墙或屋面引起的逐时冷负荷按下式计算 CL=Kq ·Fq ·(t2+td–tns) (W )(3) 式中Kq——外墙或屋面夏季传热系数[W/(m2·℃)]; Fq——外墙或屋面面积(m2); t1——外墙或屋面冷负荷计算温度(℃); td——外墙或屋面冷负荷计算温度地点修正值(℃)。 (二)、内维护结构冷负荷 内维护结构是指内隔墙及内楼板,它们的冷负荷是通过温差传热而产生的,可视作稳态传热,计算式为: CL=Kn ·Fn ·(twp+△tf–tns) (W )(4) 式中Kn——内墙或内楼板传热系数[W/(m2·℃)]; Fq——内墙或内楼板面积(m2); twp——夏季空调室外计算日平均温度(℃); △tf——附加温升,取邻室平均温度与室外温度的差值(℃)。 三、室内冷负荷 1、灯光照明引起的冷负荷按下式计算: CL=Qd·Fd (W )(5)

空调系统设计说明书_范文

设计总说明 本设计为上海市某办公楼空调通风系统设计。该办公楼属大型办公建筑,总建筑面积约为55000㎡。地下两层,地上二十八层,建筑总高度为99.6m。地下两层为车库及设备用房,地上二十八层均为办公用房。该建筑的主要功能间有办公室、会议室、接待室等。全楼冷负荷为3080千瓦,全楼采用风冷热泵机组进行集中供给空调方式。 本建筑位于上海市。上海市地处我国东部沿海地区,东经121°43′,北纬31°16′。属于亚热带季风气候区,四季分明,夏热冬冷,春秋短暂,但由于地处沿海,雨季较为分散,以夏季雨量最大。夏季空调室外日平均温度30.4℃,办公室室内温度26℃,湿度65%,室内风速v ≤0.3 m/s;冬季办公室室内温度20℃,湿度40%,室内风速v≤0.2 m/s。 设计的依据主要有同济大学浙江学院毕业设计(论文)任务书《上海市某办公楼空调通风系统设计》、采暖通风与空调设计规范GBJ19—87、HV AC暖通空调节设计指南、高层民用建筑设计防火规范GB50045—95(2005版)、GB 50189-2005 公共建筑节能设计标准、简明通风设计手册等。 考虑该大厦为办公楼,空调的运行时间主要在上班时间,所以计算负荷时本设计取的时间为6—18时。此设计中的建筑主要房间为办公室,大多面积较小,且各房间互不连通,应使所选空调系统能够实现对各个房间的独立控制,综合考虑各方面因素,确定选用风机盘管加新风系统。在房间内布置吸顶式风机盘管,嵌入暗装的形式。将该集中系统设为风机盘管加独立新风系统,新风机组从室外引入新风处理到室内空气焓值,不承担室内负荷。风机盘管承担室内全部冷负荷及部分的新风湿负荷。风机盘管加独立新风系统由百叶风口下送和侧送。水系统采用闭式双管异程式,冷水泵四台,三用一备。 在冷负荷计算的基础上完成主机和风机盘管的选型,并通过风量、水量的计算确定风管路和水管路的规格,并校核最不利环路的阻力和压头用以确定风机和水泵。 通风设计方面,地下室为车库及设备用房,设计成机械送排风为主,自然进排风为辅的方式,其换气每小时不小于6次;卫生间排风设计为排风扇机械排风到外阳台,排风量按每小时不小于10次的换气量计算;考虑到办公室吸烟问题,也采用排风扇机械排风到外阳台,排风量为送风量的80%。电梯前室及楼梯间设计加压送风。 该设计按照建筑结构及其要求制定空调方案,力求能够满足使用的要求,即能够满足办公舒适性。此外还要从空调设计的科学合理性和经济性,以及建筑整体的美观度考虑。中央空调在现代建筑中越来越多的应用,技术也越来越成熟先进。能够有效的管理,一次性投资,后期使用方便,并且不占用建筑的有效空间。本文就是对中央空调的设计到选型,到校核计算的一个说明。从使用性到科学性再到经济性上做到好的结合。方案选择是整体考虑以及设计的总体思想,计算部分是整个设计的基础,绘图部分是与设计施工相联系的实际的走管和安装。三个部分相依相承,都与整个工程密不可分。各个部分都要保证科学合理,正确无误,经济适用。 本设计是真实性课题的典例。其中,有理论的分析计算,有中央空调方案的选择论证,有实际的绘图安装。是一个完整的工程设计实例。设计计算主要有冷负荷的计算,送风量的计算,管路的计算等。冷负荷的计算确定了各个房间的空气状况和调节条件,以及整个工程的负荷量。是确定室内空调调节方案的主要数据。也是选择冷水机组最主要的参考数据。送风量和管路的计算是面向实际设备和管路的数据资料。都是整个设计的基础。 在上面主要阶段完成以后还要对一些具体细节的问题加以论证思考并列出解决方案。比如管

空调设计负荷计算说明

夏季冷负荷计算 围护结构冷负荷 外墙和屋面瞬变传热引起的逐时冷负荷,在日射和室外气温综合作用下,外墙和屋面瞬变传热引起的逐时冷负荷计算: ()()()c R c KA t t Q ττ=-(1) 式中 Q τ——外墙和屋面瞬变传热引起的逐时冷负荷,W ; K ——该面围护物的传热系数,W /(㎡·℃),可根据外墙和屋面的不同构造由《暖通空调》附录2-2和附录2-3中查取; A —— 外墙和屋面的计算面积,㎡; R t ——室内设计温度,℃; ()c t τ——外墙和屋面冷负荷计算温度的逐时值,℃,根据外墙和屋面的不同 类型分别在《暖通空调》附录2-4和附录2-5中查取。 外玻璃窗瞬变传热引起冷负荷 ()()w w c R K A t t Q ττ=??- (2) 式中 w K ——外玻璃窗的传热系数,W /(㎡·℃),可由《暖通空调》附录 2-7和2-8查得; w A ——外玻璃窗的计算面积,㎡; ()c t τ——外窗的冷负荷温度的逐时值,℃,可由《暖通空调》附录2-10查得。 透过玻璃窗的日射得热引起的冷负荷 max ()w j a s i LG c Q C C C C A D τ=?????(3) 式中 w A ——窗口面积,㎡; s C ——窗玻璃的遮阳系数,由《暖通空调》附录2-13查得; i C ——窗内遮阳设施的遮阳系数,由附录2-14查得; a C ——有效面积系数,由《暖通空调》附录2-15查得; LG C ——窗玻璃冷负荷系数,由《暖通空调》附录2-16至附录2-19查得。

人体散热形成的冷负荷 ()s LQ c q n C Q τ?=(4) 式中 ()c Q τ——人体显热散热形成的冷负荷,W ; ?——群集系数,见《暖通空调》表2-12; n ——计算时刻空调房间的总人数; s q ——不同室温和劳动性质成年男子小时显热散热量,见《暖通空调》表 2 -13; LQ C ——人体显热散热冷负荷系数,由《暖通空调》附录2-23查得。 照明散热形成的冷负荷 121000LQ N C Q n n τ=????(5) 式中 Q τ——灯具散热形成的冷负荷,W ; N ——照明灯具所需功率,kW ; 1 n ——镇流器消耗功率系数,当明装荧光灯的镇流器装在空调房间内时,取 1n =1.2;当暗装荧光灯镇流器装设在顶棚内时,可取1n =1.0; 2 n ——灯罩隔热系数,当荧光灯罩上部穿有小孔(下部为玻璃板),可利用自然通风散热于顶棚内时,取为0.5~0.6,而荧光灯罩无通风孔者取为0.6~0.8; LQ C ——照明散热的冷负荷系数,见《暖通空调》附录2-22查得。 夏季湿负荷计算 人体散湿量 60.27810w n g m φ-=????(6) 式中 n ——计算时刻空调房间的总人数; φ——群集系数,见《暖通空调》表2-12; g ——成年男子的小时散湿量,g/h ; w m ——人体散湿量,kg/s 。

空调器使用说明书

空调使用说明书 1.安全注意事项 安装环境请不要在有易燃易爆气体或有腐蚀性气体的地方安装空调器。电线、排水管和管路需要正确连接,若连接不正确可能引起空调器不工作、工作一端时间后效果变差、漏水、制冷剂泄露、触电甚至发生火灾。 请不要在洗衣房和浴室使用本空调器。 2、使用注意事项 请使用规定的交流电源,电压过高或过底可能会使压缩机无法正常工作,并对制冷系统造成损害。 使用指定规格的电源线,请勿自行改制。必须安装漏电断路器。 请不要将手指、棍棒伸入空调器的进、出风口,由于风扇高速运转,可能会造成人受伤或损坏空调器。 请不要在空调器的室内或室外机组上吊或放置物品。请不要忘记经常给室内通风,尤其是室内有煤气设备时。长期不使用时,请切断空调器电源。请不要用导线或铁丝代替断路器。 请不要将接地线与自来水管、煤气管道相连,接地不充分可能会导 致触电。 请不要在空调器运转时切断电源。 异常时(如有烧焦煳味),立即关机,切断电源,并立即报告相关领导。 请不要在可能泄露易燃气体的地方安装空调器。

请勿将空调器的风直接吹向动、植物,否则可能导致不良影响。 修理时,请与经销商或维修站联系,不当的修理可能会导致意外的事故。清扫前务必关闭空调器,切断电源,确认风扇已完全停止。 手潮湿时,请勿操作,分之可能触电。 当环境湿度过大时,在制冷或除湿运转方式下,出风口可能会滴水。 确保空调器正下放无电器设备和贵重物品。 3.重要参数 工作温度范围 室内控制板电流熔断器规格:T5AL 220V-50 HZ,额定值:60A。 本空调器额定工作大气压为一个标准大气压。 4.空调器操作方法 温度设定必须在运行模式确定之后进行(送风模式下无设定温度) 温度设定范围:19C -30 C。 温度设定也可在开机后进行。 单冷时,无自动和制热模式。制热时为防止吹出冷风,开机后室内风扇不会立即运转,将延迟一段时间。

空调毕业设计说明书

……………………. ………………. ………………… 山东农业大学 毕 业 设 计 题目:南京实验楼集中空调系统设计 院 部 水利土木工程学院 专业班级 建筑环境与设备工程2010级3班 届 次 2010 学生姓名 孙晴 学 号 20103496 指导教师 王萌 二O 一四年六月十四日 装 订 线 ……………….……. …………. …………. ………

目录 一. 设计资料及说明 (1) 二. 空调设计方案分析 (2) 三. 负荷计算 (4) 四.空气处理过程设计 (12) 五. 房间气流组织方案设计 (14) 六. 水系统的水力计算 (15) 七.风系统的水力计算 (17) 八. 冷热源的设计和布置 (19) 九.空调设备明细表 (20) 十.空调系统消声减振的设计方案 (22) 十一.空调系统控制和调节 (24) . . . 参考文献 (24) 致谢词 (25) 附录(附件) (26)

南京实验楼集中空调系统设计 作者:孙晴 10建环3班 指导老师:王萌 设计内容简介: 对南京实验楼集中空调系统进行了设计。该实验楼共三层,建筑总面积6738.24m2,其功能包括:实验室、教室、办公室。该中心总冷负荷880.83kw,总热负荷744.02kw。基于冷负荷、湿负荷、热湿比及其功能区特点,并考虑到经济性和可行性,确定出了该实验楼的具体所适用的空调系统方案,并针对此方案进行了水管风管的布置、水力计算、设备选型及设备布置及对设备的消声减振的设计。

1 设计说明及资料 1.1原始资料 1.1.1 设计地区:江苏南京 1.1.2 建筑资料:该实验楼为五层建筑,第一、二、三层有实验室,内厅,卫生间等,第四层有实验室,教室,办公室,卫生间等。第五层有教室,卫生间。现以提供各层结构平面图等。每层层高除二层为5.4m外均为4.5m,吊顶3m(局部可低)1.1.3 室内设计参数 表1-1-1 1.2 室外气象资料和围护结构资料 1.2.1室外气象资料 表1-2-1 1.2.2围护结构资料 外窗-------普通玻璃,传热系数为3.6 w/m2.℃

家用空调设计计算说明书模板

家用空调设计计算 说明书

制冷系统课程设计说明书 热能与动力工程专业 目录 一、 设计工况 .................................................................................... 4 二、 压缩机选型 ................................................................................ 4 三、 热力计算 (6) 1、循环工况:............................................................................. 6 2、 热力计算: ............................................................................ 7 四、蒸发器设计计算 . (8)

文档仅供参考 1、设计工况: (8) 2、计算过程: (9) 3、风机的选择 (19) 4、汇总 (19) 五、冷凝器换热计算 (20) 第一部分:设计计算 (20) 一、设计计算流程图 (20) 二、设计计算 (21) 3、计算输出 (27) 第二部分:校核计算 (28) 一、校核计算流程图 (28) 二、计算过程 (29) 六、节流装置的估算和选配 (30) 七、空调电器系统 (31)

一、设计工况 3KW机组,半封闭压缩机,风冷冷凝器,风冷蒸发器,毛细管,制冷剂R22,蒸发温度5℃,过热度20℃,冷凝温度50℃,过冷度5℃ 二、压缩机选型 1、选型条件:制冷量3kW,制冷剂R22,蒸发温度5℃,过热度20℃,冷凝温度50℃,过冷度5℃。 2、选型结果:使用压缩机选型软件select 6,选择型号为DKM-75的半封闭往复式压缩机。 a.其基本参数如下:制冷量3.15kW,输入功率1.06kW,cop 为2.97,电流(400V)2A,质量流量18.9g/s,放热3.65kW b. b.其技术参数:

上海市某综合楼中央空调系统设计毕业设计说明书

毕业设计(论文)原创性声明和使用授权说明 原创性声明 本人郑重承诺:所呈交的毕业设计(论文),是我个人在指导教师的指导下进行的研究工作及取得的成果。尽我所知,除文中特别加以标注和致谢的地方外,不包含其他人或组织已经发表或公布过的研究成果,也不包含我为获得及其它教育机构的学位或学历而使用过的材料。对本研究提供过帮助和做出过贡献的个人或集体,均已在文中作了明确的说明并表示了谢意。 作者签名:日期: 指导教师签名:日期: 使用授权说明 本人完全了解大学关于收集、保存、使用毕业设计(论文)的规定,即:按照学校要求提交毕业设计(论文)的印刷本和电子版本;学校有权保存毕业设计(论文)的印刷本和电子版,并提供目录检索与阅览服务;学校可以采用影印、缩印、数字化或其它复制手段保存论文;在不以赢利为目的前提下,学校可以公布论文的部分或全部内容。 作者签名:日期:

学位论文原创性声明 本人郑重声明:所呈交的论文是本人在导师的指导下独立进行研究所取得的研究成果。除了文中特别加以标注引用的内容外,本论文不包含任何其他个人或集体已经发表或撰写的成果作品。对本文的研究做出重要贡献的个人和集体,均已在文中以明确方式标明。本人完全意识到本声明的法律后果由本人承担。 作者签名:日期:年月日 学位论文版权使用授权书 本学位论文作者完全了解学校有关保留、使用学位论文的规定,同意学校保留并向国家有关部门或机构送交论文的复印件和电子版,允许论文被查阅和借阅。本人授权大学可以将本学位论文的全部或部分内容编入有关数据库进行检索,可以采用影印、缩印或扫描等复制手段保存和汇编本学位论文。 涉密论文按学校规定处理。 作者签名:日期:年月日 导师签名:日期:年月日

空调系设计说明.

民强商业大厦空调系统设计说明 概述 珠海民大以位于珠海香洲区翠前南路,是集商业、办公、酒店等诸多功能于一体城市综合体,共17层,总建筑面积21000平方米 一、商场水冷螺杆式机组系统说明 一层、二层为银行营业和商场,三层至四层为酒楼餐厅或洗浴按摩中心或卡拉OK歌厅,五层为西餐厅或健身中心,空调空调面积约4800平方米。整个空调系统采用二台日立公司高效螺杆(RCUF200WZP)+麦克维尔公司吊顶新风柜和风机盘管提供冷源,吊顶新风柜负责提供新鲜空气,风机盘管负责提供各区域所需冷量,每台风机盘管单独控制,冷量灵活调配,以后业态改变或空间大需变化时容改造,增加热量表就可进行单独计费,无需更改风管,冷却塔为方形横流冷却塔,系统分层计费方式采用超声波热量表,每层一个,如有需要可在各层单独可增加,集中监控管理系统对机房螺杆机、水泵、冷却塔、新风柜、风机盘管进行监控,根椐区域温度设定要求智能化管理控制,在监控室监控制冷系统和各层区间温度,从而降低能能耗,并统计出各区实际使用冷量,进行精准计费,在管理专用电脑实现远程管理,大大降低管理人员人数 空调水系统 1、设备布置 制冷主机设在地下室冷冻机房内,冷却塔设置在综合楼的屋顶。 2、冷冻水系统 冷冻水系统为两管制闭式循环系统,冷冻水循环泵设在地下室的制冷机房,冷冻水膨胀水箱设在综合楼的顶层天面,由给排水的供水管道向膨胀水箱补水。 3、冷却水系统 冷却水循环泵设在地下室的制冷机房,冷却塔设在综合楼的屋顶。由给排水的供水管道向冷却塔补水。 4、冷凝水系统: 根据各建筑,各层的功能不同,冷凝水就近集中排入污水系统,或由立管集中收集至首层排入污水系统。 5、空调方式 各建筑各层均采用水冷式空调机,气流组织按功能及装修要求采用上(侧)送下(侧)回。 6、空调新风及排风 1)新风从外墙防水百页新风口进来,经风柜降温处理后送到各空调区,通过对开多叶调节阀调节新风量。 2)排风量由门窗缝隙及楼梯口正压排出室外或卫生间等处排风机排出室外。 7、空调自动控制 本工程的空调控制采用就地控制+集中智能控制。 1)、抄表维护方便:超声波热量表数据自动采集,分月、分年自动统计和

中央空调系统使用说明书

基于ZigBee 的中央空调末端控制系统 使用说明书 中国科学院沈阳自动化研究所 感谢您选购我公司的产品,感谢您对我公司的信任,希望您对我们的工作提出宝贵意

前言 见。在使用之前请您仔细阅读次说明书,在阅读之后,请您妥善保管次说明书。 警告!本系统应由专门的技术人员,按照本说明书所示的安装图正确进行安 装,安装前应仔细阅读《使用说明》。 警告!为了降低受到伤害的风险,请在安装本系统前关闭电源。 系统介绍 本系统用于中央空调末端风机盘管的自动控制和远程控制,可对风机盘管的运行状态和房间内环境参数进行远程监控,通过降低中央空调末端负荷,达到空调系统的节能目的。采用本系统实现中央空调系统末端的自动控制,不会影响原有中央空调系统(机组)的正常运行,可作为其有效补充。 本系统的通信采用了短距离无线通信技术——ZigBee,系统中各设备间通过无线方式进行通信,设备可自主组网,安装、维护方便,可节省大量布线和维护成本。本系统结构如下图1 所示。 图1 系统结构

本系统中的设备主要包括:控制中心(运行监控管理软件的PC 机)、网络控制器、路由器、空调墙控器和双鉴探测器。其中,控制中心可通过以太网或RS232接口与网络控制器相连,其他设备间均为无线连接。 本系统的主要功能包括: 室内温度自动调节 风机盘管自动控制 风机盘管远程和本地控制 控制参数的远程和本地设定 室内温度显示 风机盘管运行状态监控 系统安装说明 系统的安装顺序如下: 1、规划网络,计算整个系统所需要的网络控制器、路由器、空调墙控器以及双鉴探 测器的数量,计算方法请参照各个设备的使用说明,对于信号遮挡严重的建筑结 构,要缩短路由器和空调墙控器之间的距离。 2、安装设备,按照规划好的网络安装好设备,但不要给电。 3、调试主干网络,首先打开网络控制器的电源,建立它与上位机管理软件之间的通 信,之后再打开路由器电源,查看是否每个路由器都通信正常,如果通信不正 常,请适当调整路由器天线的位置和方向,直到每个路由器都通信流畅。 4、打开空调墙控器和双鉴探测器的电源,查看是否每个设备都通信正常,如果不正 常,请调整路由器的位置。 5、通过上位机管理软件设置双鉴探测器的目标设备。 6、固化网络,通过上位机管理软件将网络的运行参数固化 网络控制器使用说明 功能说明 网络控制器具有以太网或RS232 接口,如图 2 所示。其主要功能为组建ZigBee 通信网络,负 责网络的管理和维护,通过以太网或RS232 接口 与上位机进行通信。整个网络中的节点数可多达 1000 个。 图2 具有以太网/RS232 接口的网络控制器

空调系统设计说明书

目录 1 设计依据............................................................. - 1 - 1.1 设计任务书..................................................... - 1 - 1.2 建筑平面图和剖面图............................................. - 1 - 1.3 国家主要规范和行业标准......................................... - 1 - 1.4 上海市设计计算参数............................................. - 1 - 1.5建筑围护结构的热工性能.......................................... - 2 - 1.6 设计范围....................................................... - 2 - 1.7 设计原则....................................................... - 2 - 2 负荷计算............................................................. - 3 - 2.1 夏季空调冷负荷计算............................................. - 3 - 2.1.1 围护结构冷负荷............................................ - 3 - 2.1.2 室内热源散热形成的冷负荷.................................. - 5 - 2.2 冬季热负荷的计算.............................................. - 7 - 2.2.1 围护结构基本耗热量........................................ - 7 - 2.2.2 围护结构的修正耗热量...................................... - 7 - 2.3 湿负荷计算..................................................... - 8 - 3 系统选择............................................................ - 10 - 3.1 冷热源选择................................................... - 10 - 3.1.1 选择冷热源系统的基本原则................................. - 10 - 3.1.2 冷热源系统方案的比较..................................... - 10 - 3.1.3 冷热源系统方案的确定.................................... - 11 - 3.2 空调系统的选择................................................ - 12 - 3.2.1 空调系统设计的基本原则................................... - 12 - 3.2.2 空调系统方案的比较...................................... - 12 - 3.3 空调系统方案的确定及其可行性................................. - 14 - 4 新风负荷的计算...................................................... - 1 5 - 4.1 新风量的确定................................................. - 15 - 4.2 夏季空调新风冷负荷的计算..................................... - 15 - 4.3 冬季空调新风热负荷的计算..................................... - 15 - 5 空气处理设备的选型.................................................. - 17 - 5.1 风机盘管的选型............................................... - 17 - 5.1.1 风机盘管加独立新风系统的处理过程以及送风参数计算........ - 17 - 5.1.2 风机盘管的选取.......................................... - 18 - 5.1.3 风机盘管的布置.......................................... - 19 - 5.2 新风机组的选择............................................... - 20 - 5.2.1 新风机组的计算.......................................... - 20 - 5.2.2 新风机组的型号及布置.................................... - 20 - 6 气流组织............................................................ - 21 - 6.1 气流组织分布................................................. - 21 - 6.2 风口布置..................................................... - 22 -

相关主题
文本预览
相关文档 最新文档