当前位置:文档之家› 2012狄恩电容器补偿样本

2012狄恩电容器补偿样本

Introduction 简介Capacitors

电容器

In its power factor correction systems, DNELE uses only capacitors entirely made within the facilities of its group.

Nowadays, factory is one of the few companies able to manufacture capacitors starting from the raw material up to the finished product ;the entire process is checked in order to obtain DNELE product of high quality level.

Today factory produces different type of capacitors , from the lighting and single phase motor types to the ones for power electronics (electric traction, industrial services) and those of medium voltage. The various characteristics demanded to these products in terms of electric, mechanical and thermal stress ,enabled to find technical solutions that have been applying in other fields with interesting results: for instance the optimization of capacitors for special applications enabled to find very strong solutions that have been then applied on power factor correction capacitors.

The production of the dielectric film (polypropylene or special paper), the metallization process, the production of the capacitor and the construction of the power factor correction banks are fully executed within companies of the Group; that guarantees the achievement of the highest quality standard weather of the metalized film or, consequently, the capacitors manufactured. Furthermore, the knowhow acquired in almost 50 years of metalized film production, has enabled our to realize absolute innovative products like 3Ut range of capacitors.

Used to deal with International markets factory faced the requests of the strictest Certification Bodies and was awarded UNI EN ISO 9001:2000 Certification. Factory periodically takes part to CEI/IEC committees for the compilation of the product regulations , aimed at setting the objective criterions to evaluate capacitors performances and safety. It’s constantly in the vanguard and able to anticipate the regulations requirements; in order to ensure the accordance with the International regulations and the most strict customers acceptance criterions, products are submitted to tests in the internal laboratories (where it’s possible to test capacitors up to 700μF and voltage up to 80kV) and in the greatest internationally recognized laboratories (CESI) .

Everything is performed for the safety of the customer who entrusted a reliable partner with a pluridecennal experience in capacitors production for the most disparate applications .

在无功补偿系统里面,DNELE 电容器的核心组件全部由自己生产。

如今,工厂是全球少数几家能够从原材料到成品生产电容器的厂家之一,为了保证产品的品质,我们在整个生产过程中都要进行检测.正因如此 DNELE 的产品品质得到了最好的保证。

现在工厂生产不同种类的电容器。灯具电容,单相的马达电容,电力电子电容(电力牵引,工业服务)和中压电容。产品的各种特性使他们被广泛的应用于电气,机械和热能方面,以确保能找到在其他领域应用的技术解决方案。例如,为了特殊要求的电容器最优化而找到的最佳解决方案已被应用到无功补偿电容器中。

介质膜的生产(聚丙烯或特殊纸张),金属化的过程,电容器的生产,无功补偿系统的生产,都完全在集团公司内部完成。这保证了金属化膜和电容器产品的高品质要求。而且,以工厂50年的金属化膜的生产经验。使我们创新制造了3ut 标准的电容器。

为了打开国际市场,工厂提高了各种生产管理机制,并取得了UNI EN ISO 9001:2000的认证。工厂定期参与CEI/IEC 委员会产品规范的制定,使产品的性能和安全性有了一个客观的标准。工厂一直持续不断的走在规范要求的前列,为了确保产品按照国际规范生产和一些高品质要求的客户的认可,我们的产品会在工厂内部的实验室接受700μF 和80KV 电压的测试,或送到国际上最权威的实验室(CESI )进行检测。

我们将在不同的领域成为您安全可靠的合作伙伴!

Introduction

High density metalized polypropylene film capacitors The film used in the MKPDS power capacitors comes directly from the MKPDS experience in the high performance capacitors, in particular it is defined as “High density metalized polypropylene film”.

The main difference in comparison to standard polypropylene capacitors is the way in which the dielectric film is metalized. In standard polypropylene capacitors the thickness of the metal layer deposited on the film surface is constant; in 1995, instead, factory has developed a manufacturing process that enables obtaining a metal layer with properly modulated thickness and achieving extraordinary results in the capacitors field for direct current and energy storage applications. Subsequently, this technology has been extended to capacitors for alternating current applications, with same remarkable results

in power factor correction of industrial facilities.

The modulation of the metallization thickness, allows considerably betters capacitors performances (and therefore the one of the power factor corrector systems of which they are the basic component ) in terms of :

---- Increased specific power (kvar/dm3)with resulting reduction of power factor corrector systems dimension ;

---- Improvement of the strengthens to continuous and temporaries overvoltage for a better reliability even in plants with

voltage peaks due to the network or manoeuvres on the plant ; 3Ut capacitors are in fact tested at three times the rated voltage (type test) from which procedure comes their name ;

---- Better reaction to the internal short circuit thanks to the special metallization with variable thickness .

简介

高密度金属化薄膜电容器

MKPDS 电容器使用的金属化聚丙烯薄膜直接来自于工厂丰富的生产经验,准确的说是”高密度金属化聚丙烯薄膜”

他与标准的聚丙烯薄膜电容器的主要区别就是他的薄膜是变量金属层的。而标准聚丙烯薄膜的金属层厚度是均匀的 .在1995年,工厂有了成熟的生产工艺开始生产变量金属层聚丙烯薄膜,在直流和能量储存电容器领域取得了非凡的成果。后来这个工艺被延伸到交流电容器的应用中,在无功补偿领域也取得了同样的显著的成果。

变量的金属层厚度,使电容器的性能得到很大的提高(金属化薄膜是无功补偿的核心组件之一)

---- 增加特定容量的无功补偿系统不会因此而增加尺寸。---- 在连续变化的过电压甚至在电网的电压峰值环境中,都具有很好的可靠性,3ut 电容器 意味着取得这个认证必须经过3次形式实验。

---- 变量的金属层使电容器的性能在内部短路时也具有很好的表现。

The capacitors main characteristics

Volume

the capacitor is the cylindrical, we make it more small volume, lighter weight and lower height by advanced technology and manufacturing process.

Self-healing

All dielectric structures used in our power capacitors are “self-healing” :In the event of a voltage breakdown the metal layers around the breakdown channel are evaporated by the temperature of the electric arc that forms between the electrodes . They are removed within a few microseconds and pushed apart by the pressure generated in the centre of the breakdown spot .An insulation area is formed which is reliably resistive and voltage proof for all operating requirements of the capacitors .The capacitor remains fully functional during and after the breakdown .

IP20 Protection:

The terminal block of designs K ,L and M is rated IP20 , i,e,it is protected against accidental finger contact with live parts .The discharge modules are designed in the same way.

Protection against Overload and Failure at the end of Service Life

In the event of overvoltage or thermal overload or ageing at the end of the capacitor’s useful service life ,an increasing number of self-healing breakdowns may cause rising pressure inside the capacitor . To prevent it from bursting ,the capacitor is fitted with an obligatory 《break action mechanism 》.This safety mechanism is based on an attenuated spot at one ,two ,or all of the connecting wires inside the capacitor .With rising pressure the case begins to expand ,mainly by opening the folded crimp and pushing the lid upwards .As a result ,the prepared connecting wires are separated at the attenuated spot ,and the current path is interrupted irreversibly .

电容器主要特点

体积

体积小,圆柱形设计,通过新的技术和工艺使电容器的体积更小,重量轻,高度低,满足用户对立体空间的要求。

自愈式

我们电容器采用的电介质都具有自愈功能:如果电压击穿金属层,电极间的电弧会在击穿点周围产生高温,金属层会迅速蒸发逸散,这些逸散的金属导体会在几微秒内被移动并且在击穿点中心压力的作用下被推挤,这样就形成了一个绝缘的区域从而有效的抵抗电压击穿,电容器击穿自愈后还可以正常使用。

IP20防护

电容器的接线端子是按IP20的防护等级设计,这是防止手指接触到带电的部分。放电电阻也是同样的设计。

过压拉断保护

在电容器使用的过程中,如果有许多过电压,过热,老化的情况发生,就会在电容器内部产生很多自愈性的破坏,从而导致电容器内部的压力增加。为防止电容器的突然破裂,就必须在电容器内部安装一个压力开关,这个安全机制是在电容器内部连接线上做1个,2个或者更多的点,随着压力的不断上升,通过拉开有褶的部分来释放压力,而将连接线上准备好的点拉断,有效的阻碍了电流的通过,防止电容器因过载或过热而引起的爆炸。

Discharge :

Capacitors should be discharged to ≤10% of the rated voltage prior to being re-energised . For this purpose ,

special discharge modules are offered which can be selected in accordance with the applied operating voltage and the desired discharge period . Standard IEC 60831 requires a discharge to 75V or less within 3 minutes .

放电电阻

电容器必须放电到之前存贮电压的10%以下,放电电阻模块能够在要求的时间内达到这个目的 IEC 60831的标准要求是在3分钟内将电容器的端电压降到75V以下。

Service life :

Capacitor have 200,000 operating hours service life

because the advanced manufacturing process for metal

layer and test equipment .

使用寿命

我们先进的薄膜生产工艺和检测机制,使得我们的电

容器的工作寿命能达到200000小时。

Technical Data 技术参数

Outside Drawing 外形图

Specification List 产品列表Standards74/64-0650

E

D

V

,)3002(13806

C

E I

5891

M-091.o

N

2.22

C

A

S

C

018.o

N

d r a d n a t S

L

U

88-2821

T

S

O

G

approval marks

*design K/L/M 5…60kvar, ≤660V_*Bauform K/L/M 5…60kvar, ≤660V

**all 3-phase capacitors_**alle 3-phasige K ondensatoren

CE Conformity

All capacitors in this brochure are declared to conform to the following European D irectives:

73/23/EWG L ow-V oltage D irective

93/68/EWG D irective for amendment of directive 73/23/EWG (CE-Conformity Mark)

rated voltages 230 ... 800 V

maximum permissible current

1.5…2 I N

tolerance of capacitance - 5 ... + 10%, ± 5%, 0 ... + 10%

internal connection delta

dissipation losses

dielectric < 0.2 W/kvar

total capacitor 0.25 ... 0.4 W/kvar

temperature class-40°C/D

humidity 95%

altitude abv.s.l. < 4000m

life expectancy > 200 000 h

permitted operating voltages

higher values on request

**

rated frequencies50/60Hz

额定电压

最大允许电流

允许操作电压

认证标志

执行标准

电容容差

电介质

整个电容

温度等级

湿度

使用寿命

海拔

散逸损耗

内部联接方式三角形

额定频率

1.0xUn

24h:

1.1xUn

8h/d:

1.15xUn

30min/d:

1.2xUn

5min(200x):

1.3xUn

1min(200x):

Introduction

The growing use of power electronic devices is causing an increasing level of harmonic distortion in the electrical systems, which frequently leads to problems with capacitor installations. This is the reason why energy suppliers and actual conditions require the usage of harmonic blocking reactors.

A detuned capacitor system works out the function of power factor correction whilst preventing any amplification of harmonic currents and voltage caused by resonance between capacitor and inductance impedances of the electrical system .

By adding an appropriately rated series reactor to the power capacitor, both elements form a low-pass resonant circuit (usually below the 5th harmonic) which prevents higher order harmonics to flow into capacitors .

DNELE harmonic blocking reactors are made of high-class transformer sheets and aluminiun coils. They are fully manufactured at our premises, dried and impregnated in a vacuum with environmentally friendly, low-styrole resin which ensures high voltage withstand, low noise levels, and enjoys a long operating life.简介

随着电力电子设备使用的不断增多,造成电网中谐波失真情况增加,从而导致电容器经常出现问题。这就是为什么越来越多的客户要求安装滤波电容器系统的原因。

滤波电容器系统在完成功率因数改善的同时,也能防止被放大的谐波电流和电压在电网中造成电容和电抗之间的谐振。

通过增加一个电抗器在电容器系统中,他们之间形成的共振频率低于系统中的谐波频率(通常低于5次谐波)这样就阻止了高频率的谐波流入到电容器中。

DNELE滤波电抗器是由高纯度的材料制造,通过真空浸渍和干燥,确保了产品耐高压,低噪音,长寿命的特点。

附注:表中所列电容器为常用规格,其它非常用规格电容器因种类繁多,在此不做具体说明。如有需要请与本公司联系。

Reactor Main Characteristics

Capacitor Voltage Uc

Required voltage strength of the capacitor : The series connection of capacitor and reactor causes a voltage rise at the capacitor terminals as described by the following formula which must be considered when selecting a capacitor for the application .( Rated voltage of capacitor >430V )

Detuning Factor p

Ratio between the reactances

of reactor X L and corresponding capacitor Xc ( in % )

The detuning factor determines the series resonance frequency between reactor and capacitor which in turn is important for the blocking and filtering effect.

电抗器主要特点

电容端电压 Uc

电容器电压等级的要求:串联的电抗器会使电容器的端电压升高。具体如以下的计算公式,为我们选择电容器的额定电压提供一个参考。(电容器的额定电压必须大于430V)

电抗率 p

电抗器的阻抗值和电容器的阻抗值的比值

电抗率决定了电容器和电抗器之间的谐振频率,电抗率对滤波的效果有直接的影响。

p = 100% · X L

X C

p = 100% · X L

X C

Series Resonance Frequency f r

The standard reactors listed in this catalogue have been designed for common detuning factors and resonance frequencies as shown on the right:

Dissipation Power P eff

Sum of all iron-, copper-, and stray ?eld losses at max. speci?ed over-voltage and harmonic content. Depending on the detuning factor, the effec-tive dissipation power of

our reactors is between 4 and 6W/kvar.

Temperature Switch

All reactors are provided with a separate screw terminal for the temperature switch (opening switch) which is

located inside the central coil. 谐振频率

右图所示的是常见的电抗率和谐振频率

损耗功率

铁、铜的总和以及隔离层的损耗最大,尤其是过电压谐波因素的存在,考虑到要调整的功率因数。一般我们电抗器的损耗在4~6W/Kvar

温度开关

所有的电抗器都在线圈的中央安装了一个单独的温度控制开关。

f r

f N = rated system frequency

D etuning factor

Resonance frequency f r

p

N = 50 Hz N = 60 Hz 5.67% 210 Hz 252 Hz 7% 189 Hz 227 Hz 14% 134 Hz –

f r = f N ·

100%

p

f f 电抗率响应温度电压公差

谐振频率

response temperature 125 C °

voltage 250V ac (<6.3A) …500V ac (<2A)tolerance ± 5K

Outside Drawing 外形图

Reactors 电抗器

Thyristor Switch

无触点投切开关

Introduction

Immediate COMPENSATION of inductive reactive power is very often the only way to cope with disturbances imposed on the mains by huge, rapidly changing inductive loads. Conventional capacitor switching devices with reaction periods of 20-----90

seconds can not comply with such intensive requirements.

The DN-TSC thyristor switch module makes reaction times of 1…..20 milliseconds possible. The switching is done, practically without reactive effects, at zero voltage level (no voltage between input and output). DN-TSC has a very compact design, convenient connection, integral overheating protection, and LED indication for the switching signal and excessive temperature. For powers above 25kvar, a controllable fan is included.

简介

快速投切开关是处理强电流干扰无功功率最常用的办法。常规的电容器投切开关的反应时间为20-90秒,不能完全满足快速投切的需要。

DN-TSC 可控硅投切开关的反应时间在1-20毫秒,没有任何的机械磨损,实现过零投切,DN-TSC 可控硅投切开关具有设计紧凑,方便连接,过温度保护,LED 投切状态信号灯,内置冷却风扇

等特点。

Standards EN 61558-2-20:2000, VD E 0570-2, IEC 60076-6:2007

U L 508, C22.2 No.14

approval marks rated voltages 700V

...230rated frequencies 50/60Hz tolerance of inductance (mean value across three phases ) ±3%

linearity I lin = 1.8…2.5 I N

For details see data charts, higher values on request_D etails siehe D atentabellen, andere Werte erh?ltlich auf Anfrage

harmonic load (continuous operation)

U 3 = 0.5% U N

U 5 = 6.0% U N U 7 = 5.0% U N U 11 = 3.5% U N U 13 = 3.0% U N insulation (winding-to-core)

3k V temperature class T40

insulation class protection class I P 00 indoor mounting humidity 95%

cooling natural cooling altitude abv.s.l. 4000m

design three phase, iron core multiple air gap /winding material Copper /Aluminium impregnation P olyester resin, class F(H) terminals Terminal blocks, cable lugs, or temperature-proof ? exible cables

认证标志

额定电压额定频率

电感值差线性度

谐波负荷(持续性)

执行标准耐压(对中心)温度等级绝缘等级保护等级湿度H 级(180 C)

冷却方式自然冷却海拔设计

缠绕材料浇注方式端子三相 铁心多气隙

铜/铝

聚酯树脂 等级 F(H)

接线盒 缆绳座

耐热柔性电缆

Technical Data 技术参数

Specification List 产品列表

Diagiam 接线图

附注:表中所列电抗器为常用规格,其它非常用规格电抗器因种类繁多,在此不做具体说明。如有需要请与本公司联系。

Thyristor Switch 无触点投切开关Power Factor Controller

功率因数控制器

Introduction

The intelligent regulation algorithm of DNELE switches the steps optimized and by this it guarantees short compensation times combined with the smallest amount of operations. The

operating cycles are shared equally to all steps .

All relevant parameters for the regulation are set ex words in the way that in nearly all cases for DN-PFR no further adjustments are necessary to start the regulation. An optimization of the control mode of the compensation panel to the local conditions is still possible. Parameters can easily be

changed, also during operation.

DN-PFR is equipped with LCD with backlit. It shows information about the panel and about the mains parameters. It’s also necessary for setting the parameters of DN-PFR

By using the temperature sensor ,DN-PFR can measure the internal temperature of the compersation panel and can swith by

using one of the control outputs a fan.

The monitoring features of DN-PFR guarantee a reliable operation and a long life of the compensation panel:

---- Low voltage switch-off against chattering of contactors ----Over voltage switch-off for protecting the capacitors ----Overtemperature switch-off

----Monitoring of THD U and switch-off by exceeding THD U ----Recognition of defective capacitors

----Alarming ,when target of regulation cannot be reached ----Signaling of the need for maintenance -----Fan control

简介

DNELE 控制器是一种智能型的控制器,他以最优化的步数,最少数量的操作保证了最短的投切时间,所有的步骤都可以在同一个操作周期内完成。

DN-PFR 控制器在出厂时已经完成了所有相关参数的基本设置,因此在大部分情况下,在开始工作前,都不需要做进一步的设置。在设备的运行期间,我们同样的可以根据现场情况的变化,很容易的去改变已经设置过的各种参数。

DN-PFR 装备的是背光式LCD 显示屏,可以在面板上显示所有的主要参数,这就方便了对系统参数的设置。

DN-PFR 能通过温度传感器,测量柜体内部温度,以控制风扇的开关。

DN-PFR 的检测功能有效的保证了系统的可靠工作和长寿命。

-针对接触器震动的开关-过电压电容器保护开关-过温度保护开关-THD 电压监控-电容减容监测

-目标功率因素未达到报警-系统维护信号报警-风扇开关

Technical Data 技术参数

Outside Drawing 外形图

H

W

W

L

Power Factor Controller 功率因数控制器

Power Factor Controller

功率因数控制器

DN-PFR-AX

Standards DIN VDE 0110 Teil 1 (IEC 60664-1:1992)

VDE 0411 T eil 1 (DIN EN 61010-1 / IEC 61010-1:2001) VDE 0843 T eil 20 (DIN EN 61326 / IEC 61326: 1997 +

:1998+A2:2000) 1A GOST R 52319-2005, GOST R 51522-99 UL 508 – Industrial Cont rol Equipment

CSA C22.2 No. 14-M95 - Industrial Control Equipment

Approval marks 线电压相电压电流有功功率无功功率

达到目标功率因数所需要的无功当前有功功率电压谐波3th~15th 电压谐波目标功率因数功率/视在功率平均功率因数频率温度最大温度运行时间

第一路设置原始功率百分比投切循环类型第二路设置::

第十四路设置

第一路 投入状态 切除状态........................

第十四路 投入状态 切除状态

INFO段数信息

手动运行状态

Measuring Display 监测显示: V, A, Kva ,kvar, cosphi, PF, kvar, THD U, 3rd to 19th harmonic of voltage 3到19次谐波电压 Information Display 信息显示: Switch cycles per step, capacitor rating, status of the exits , operating hours of the panel,

max .temperature , average PF 每步投切周期,电容等级,运行时间,最大温度,平均视在功率 Measuring-and Auxiliary 90-550V AC, single phase, 45-65Hz, 5VA, max. fuse 6A, VT ratio from 1,0 to 350, 0Voltage 测量电压和工作电压: 90-550V AC ,单相45-65Hz ,5VA ,最大熔断6A ,电压互感器变比为1---350 Current Measuring 电流测量: 15 mA-6A, single phase , burden 20 m 0hm, CT ratio from 1 to 9600

15 mA-6A ,单相20 m 0hm ,电流变化范围:1---9600

Control Outputs 控制输出: Up to 14 relay, N/O, voltfree with common point, max. fuse 6 A, 继电器,无源点,最大熔断6A

breaking capacity: 250 V AC / 5 A ,400 V AC /2A 最大开断容量250 V AC / 5 A, 400 V AC /2A Temperature measuring: By NTC 温度测量:

通过NTC

Sign-Of-Life contact: Relay, voltfree, N/O, max. fuse 4 A, breaking capacity: 250 V AC / 5 A, 400 V AC /2A 报警接点:

继电器,无源点,最大熔断4A ,最大开断容量250 V AC / 5 A, 400 V AC /2A Fan Control 风机控制: By using a control output 通过使用一个投切输出点Ambient Temperature: Operation : -20℃-70℃ ,storage : -20℃-85℃当前温度: 运行温度:-20℃-70℃ 存储温度:-20℃-85℃

Humidity 湿度:

0% -98%, without moisture condensation 0% -98%无结露

Overvoltage class 电压水平: II, pollution degree 3 ( DIN VDE 0110, part 1/IEC 60664-1 ) II 污染等级3Terminals 连接: Plugable terminal blocks 可插拔式端子

Casing 外壳: Front: instrument casing plastic ( UL 94-VO) 前面:树脂结构

Rear: metal 后面:金属结构

Protection Class 防护等级: Front: IP 50 ( IP 54 by using a gasket between relay and panel) 前面:IP 50

Rear: Ip20 后面:IP 20Weight 重量: approx. 0.6kg

Dimensions 尺寸:

144x144x58mm hxwxd, cutout 开孔尺寸 138 (+0.5 )x138 (+0.5mm)

Diagiam 接线图

Technical Data 技术参数

执行标准认证标志

Power Factor Controller 功率因数控制器

Chinese Customers

中国客户

菜单调试说明:

1. 控制共有6项操作菜单,常用的为100的菜单中内容;选择SET UP 按控制器上的右侧按键可进入设定;

2. 控制器有上电自检功能,投切所有的回路,控制器可自动计算每路的容量,如果其中一路(或多路)没有容量值,请检查回路的熔断器,接触器和电容器;

3. 手动设定每组的容量:在菜单中代号为402的选项中可设定每路的电容器容量。选择SET UP 按控制器上的右侧按键(按住3秒后)可进入设定;注意!在控制器自检时检测不到容量是因为接触器的动作响应时间慢造成的,如果是这样可进入402菜单中手动设定这路的容量,在403中必须把这路的类型选择为AOTU (自动状态。)因为控制器检测不到容量后会把这路自动关闭。

4. 建议控制器运行正常后把208菜单设定为NO ,上电自检功能屏蔽。

5. 每路输出的类型为AUTO (自动),FOFF (常关闭),FON (常投入),AL (报警控制)。 在控制器不正常后请确认每路的输出类型是否正常,不用的输出回路请关闭。查看在403项中。

高校研究

复旦大学上海交通大学华东师范大学上海海事大学上海大学上海理工大学上海交通大学体育馆北京航空航天大学

航空机场

北京国际首都T3机场昆明国际机场

金融银行

中国农业银行银行数据处理中心中国人民银行数据处理中心中国商业银行数据处理中心中国银行数据处理中心招商银行发卡中心招商银行招商大厦

上海期货交易所数据处理中心

通讯业

中国移动上海分公司中国移动福建分公司中国电信上海分公司中国电信数据处理中心中国电信国家安全中心中国电信后勤保障中心中国电信园区临港信息大楼中国电信呼叫中心上海金桥通汇数据处理中心上海电信信息园区上海电信综合服务中心上海移动怒江北路局房上海移动钦州路76号局房上海移动奉贤移动大楼上海移动金桥局房上海移动金山局房上海电信行政办公楼上海数讯数据处理中心

汽车业

上海通用汽车上海雅马哈发动机上海大众汽车上海幸福摩托总厂博世汽车(南京)有限公司

钢铁业

中国中钢集团公司河北德龙钢铁有限公司

电子类

上海京瓷电子有限公司英业达科技(上海)有限公司英业达科技(重庆)有限公司英源达科技(上海)有限公司松下半导体(苏州)有限公司三星电子

富士康电子(昆山)有限公司英特尔半导体(大连)有限公司

商业类

上海环球金融中心上海嘉定江桥万达广场上海漕河泾开发区现代服务中心上海漕河泾开发区绿洲科技上海漕河泾开发区总部大楼上海静安城市航站楼

上海漕河泾开发区齐来工业城大楼上海漕河泾国际商务中心上海临港皇冠假日酒店江苏无锡新城万博城市广场江苏常州新城万博城市广场安徽合肥港汇广场安徽合肥喜来登大酒店百联浙江奥特莱斯品牌广场无锡嘉利国际广场无锡市民广场包头市国际会展中心

医院

上海仁济医院上海第一人民医院上海第六人民医院上海第十人民医院上海质子重离子医院上海浦东人民医院上海五官科医院上海金山医院大楼安徽合肥中心医院江苏盛泽医院河北沧州医院浙江海盐人民医院海军总医院江苏无锡人民医院苏州太仓第一人民医院无锡人民医院

工业类

中国三一重工集团徐工集团上海临港工业园区中国船舶重工集团公司大连造船厂恩施卷烟厂安徽矿业机电广西卷烟厂

江苏常州天合光能有限公司汉能控股集团有限公司江苏南通中技桩业大庆油田

华油天然气广安有限公司内蒙古呼和浩特神舟硅业有限公司上海天马集团武汉天马微电子有限公司陕西宝鸡金台纸业

布兰肯(徐州)金属制造有限公司百事亚洲(上海)研究中心

市政类

上海外高桥保税区上海市静安公安局大楼上海文化广场上海市群众艺术馆上海松江污水处理厂上海南汇森林公园国家电网数据处理中心山东曲阜汽车站浙江甬台温铁路山西怀仁县黄河供水工程新疆乌鲁木齐市污水厂江苏南京污水处理厂江苏南京水利厂

四川成都凤凰山高位水池及洪河加压泵站重庆三块碑水厂重庆鸡冠石污水处理厂江苏常州江边污水处理厂四川内江污水处理厂四川成都岷江自来水厂重庆白洋滩水厂山西金海洋黄河供水怀远县自来水厂安徽霍邱县自来水厂内蒙古鄂尔多斯会展中心重庆大剧院江苏无锡大剧院人民日报企业

Specification 说明书

DN-MKPDS 电容器

DN-FK 电抗器DN-PFR 控制器

DN-TSC

投切开关

地址 :上海市仙霞路369号现代广场1805室

Add :1805,Xiandai Plaza No.369 Xianxia Road, Shanghai 电话/Tel :+86 21 3252 8699传真/Fax :+86 21 3252 8696邮箱/E-mail :sales@https://www.doczj.com/doc/534420883.html, 狄恩电气(上海)有限公司

DN-Electric (Shanghai) Co.,Ltd.

C A P A C I T O R S A N

D R

E A C T O R S

F O R L .V . P O W E R F A C T O R C O R R E C T I O N

低压无功补

2012

Distributor 经销商:

并联电容器无功补偿方案

课程设计 并联电容器无功补偿方案设计 指导老师:江宁强 1010190456 尹兆京

目录 1绪论 (2) 1.1引言 (2) 1.2无功补偿的提出 (3) 1.3本文所做的工作 (3) 2无功补偿的认识 (3) 2.1无功补偿装置 (3) 2.2无功补偿方式 (4) 2.3无功补偿装置的选择 (4) 2.4投切开关的选取 (4) 2.5无功补偿的意义 (5) 3电容器无功补偿方式 (5) 3.1串联无功补偿 (5) 3.2并联无功补偿 (6) 3.3确定电容器补偿容量 (6) 4案例分析 (6) 4.1利用并联电容器进行无功功率补偿,对变电站调压 (6) 4.2利用串联电容器,改变线路参数进行调压 (13) 4.3利用并联电容器进行无功功率补偿,提高功率因素 (15) 5总结 (21) 1绪论 1.1引言 随着现代科学技术的发展和国民经济的增长,电力系统发展迅猛,负荷日益增多,供电容量扩大,出现了大规模的联合电力系统。用电负荷的增加,必然要

求电网系统利用率的提高。但由于接入电网的用电设备绝大多数是电感性负荷,自然功率因素低,影响发电机的输出功率; 降低有功功率的输出; 影响变电、输电的供电能力; 降低有功功率的容量; 增加电力系统的电能损耗; 增加输电线路的电压降等。因此,连接到电网中的大多数电器不仅需要有功功率,还需要一定的无功功率。 1.2无功补偿的提出 电网输出的功率包括两部分:一是有功功率;二是无功功率。无功,简单的说就是用于电路内电场与磁场的交换,并用来在电气设备中建立和维持磁场的电功率。电机和变压器中的磁场靠无功电流维持,输电线中的电感也消耗无功,电抗器、荧光灯等所有感性电路全部需要一定的无功功率。为减少电力输送中的损耗,提高电力输送的容量和质量,必须进行无功功率的补偿。 1.3本文所做的工作 主要对变电站并联电容器无功补偿作了简单的分析计算,提出了目前在变电站无功补偿实际应用中计算总容量与分组的方法,本文主要作了以下几个方面的工作: 对无功补偿作了简单的介绍,尤其是电容器无功补偿,选取了相关的案例进行了简单的计算和分析。 2无功补偿的认识 2.1无功补偿装置 变电站中传统的无功补偿装置主要是调相机和静电电容器。随着电力电子技术的发展及其在电力系统中的应用,交流无触点开关SCR、GTR、GTO等相继出现,将其作为投切开关无功补偿都可以在一个周波内完成,而且可以进行单相调节。如今所指的静止无功补偿装置一般专指使用晶闸管投切的无功补偿设备,主要有以下三大类型: 1、具有饱和电抗器的静止无功补偿装置; 2、晶闸管控制电抗器、晶闸管投切电容器,这两种装置统称为SVC 3、采用自换相变流技术的静止无功补偿装置——高级静止无功发生器。

电容补偿的计算公式

电容补偿的计算公式 Document serial number【UU89WT-UU98YT-UU8CB-UUUT-UUT108】

电容补偿的计算公式未补偿前的负载功率因数为COS∮1。负载消耗的电流值为I1。 负载功率(KW)*1000 则I1=---------------------- √3*380*COS∮1 负载功率(KW)*1000 则I2=---------------------- √3*380*COS∮2 补偿后的负载功率因数为COS∮2,负载消耗的电流值为I2 则所需补偿的电流值为:I=I1-I2 所需采用的电容容量参照如下: 得到所需COS∮2每KW负荷所需电容量(KVAR) 例: 现有的负载功率为1500KW,未补偿前的功率因数为COS∮1=,现需将功率因数提高到COS∮2=。则

1500*1000 则I1=-----------------=3802(安培) √3*380* 1500*1000 则I2=------------------=2376(安培) √3*380* 即未进行电容补偿的情况下,功率因数COS∮1=,在此功率因数的状况下,1500KW负载所需消耗的电流值为I1=3802安培。 进行电容补偿后功率因数上升到COS∮2=,在此功率因数的状况下,1500KW负载所需消耗的电流值为I2=2376安培。 所以功率因数从0.60升到。所需补偿的电流值为I1-I2=1426安培 查表COS∮1=,COS∮2=时每KW负载所需的电容量为,现负载为1500KW,则需采用的电容量为1500*=1560KVAR。现每个电容柜的容量为180KVAR,则需电容柜的数量为 1500÷180=个即需9个容量为180KVAR电容柜。

电容器补偿容量计算和安装容量【海文斯电气】

电容器补偿容量计算和安装容量【海文斯电气】 1、电容器补偿容量计算 在电网实现无功补偿实际上是通过对电容器进行投切来进行的,使电网系统能够处于稳定状态。通过确定电容器容量的补偿容量,可提高整个无功补偿系统的可靠性以及补偿效果。但在进行无功补偿之前必须要确定所需补偿容量的大小,这就需要掌握电容器补偿容量的计算方式。假设配电网中的有功功率为P,所需补偿的无功功率为Q C,补偿前的功率因数为cosα,补偿后要得到的目标功率因数为cosβ,则补偿容量可用下图计算: 通过Q C=U2ωC可以计算出补偿所需要的电容器容量,即: 如果无功补偿投入与切除电容器的功率因数门限分别设定为cosθ1、cosθ2,则通过计算,可得到的补偿容量公式如下图所示。 2、电容器安装容量分组方式 在实际应用中,如果一次投入电容器组容量过大,会对电网造成冲击。所以在得出补偿容量之后,需要把电容器分成多组进行投切。合理的分组,可以使各组电容器的投切次数基本相等,降低电容器投切频率,从而提高了电容器的使用寿命。电容器的分组方式可分为等容分组与不等容分组方式。 所谓的等容分组方式,就是各组电容器的容量相等,这样比较容易控制,在补偿时各组电容器可以相互替换。海文斯电气给出的建议是让各分组电容器容量不相等,例如需要补偿200kvar,可采取180kvar、20kvar进行组合补偿,日常自动采用180kvar补偿,当补偿不够是,投切20kavr的分组,这样可以大大提高补偿精度。 在综合考虑补偿效果和经济效益的前提下,海文斯电气给出的建议是采用容量不相等分组方式,该方式控制过程虽然较为复杂,但是可大大提高补偿精度。

无功补偿容量计算

无功补偿容量计算 Prepared on 22 November 2020

一、无功补偿装置介绍 现在市场上的无功补偿装置主要分为固定电容器组、分组投切电容器组、有载调压式电容器组、SVC和SVG。下面介绍下各种补偿装置的特点。 1)固定电容器组。其特点是价格便宜,运行方式简单,投切间隔时间长。但它对于补偿变化的无功功率效果不好,因为它只能选择全部无功补偿投入或全部无功补偿切出,从而可能造成从补偿不足直接补偿到过补偿,且投切间隔时间长无法满足对电压稳定的要求。而由于光照强度是不停变化的,利用光伏发电的光伏场发出的电能也跟着光伏能力的变化而不断变化,因此固定电容器组不适应光伏场的要求,不建议光伏项目中的无功补偿选用固定电容器组。 2)分组投切电容器组。分组投切电容器组和固定电容器组的区别主要是将电容器组分为几组,在需要时逐组投入或切出电容器。但它仍然存在投切间隔时间长的问题,且分的组数较少,一般为2~3组(分的组数多了,投资和占地太大),仍有过补偿的可能。因此分组投切电容器组适用于电力系统较坚强、对相应速度要求较低的场所。 3)有载调压式电容器组。有载调压式电容器组和固定电容器组的区别主要是在电容器组前加上了一台有载调压主变。根据公式Q=2πfCU2可知,电容器组产生的无功功率和端电压的平方成正比,故调节电容器组端电压可以调节电容器组产生的无功功率。有载调压式电容器组的投切间隔时间大大缩短,由原来的几分钟缩短为几秒钟。且有载调压主变档位较多,一般为8~10档,每档的补偿无功功率不大,过补偿的可能性较小。因此分组投切电容器组适用于电力系统对光伏场要求一般的场所。

并联电容器补偿装置基础知识

并联电容器补偿装置基本知识 无功补偿容量计算的基本公式: Q = P (tg φ1——tg φ2) =P( 1cos 1 1cos 12 2 12---?? ) tg φ1、tg φ2——补偿前、后的计算功率因数角的正切值 P ——有功负荷 Q ——需要补偿的无功容量 并联电容器组的组成 1.组架式并联电容器组:并联电容器、隔离开关(接地开关或隔离带接地)、放电线圈、串联电抗器、氧化锌避雷器、并联电容器专用熔断器、组架等。 2.集合式并联电容器组(无容量抽头):并联电容器、隔离开关(接地开关或隔离带接地)、放电线圈、串联电抗器、氧化锌避雷器、组架等。 并联电容器支路串接串联电抗器的原因: 变电所中只装一组电容器时,一般合闸涌流不大,当母线短路容量不大于80倍电容器组容量时,涌流将不会超过10倍电容器组额定电流。可以不装限制涌流的串联电抗器。 由于现在系统中母线的短路容量普遍较大,且变电所同时装设两组以上的并联电容器组的情况较多,并联电容器组投入运行时,所受到的合闸涌流值较大,因而,并联电容器组需串接串联电抗器。 串联电抗器的另一个主要作用是当系统中含有高次谐波时,装设并联电容器装置后,电容器回路的容性阻抗会将原有高次谐波含量放大,使其超过允许值,这时应在电容器回路中串接串联电抗器,以改变电容器回路的阻抗参数,限制谐波的过分放大。 串联电抗器电抗率的选择 对于纯粹用于限制涌流的目的,串联电抗器的电抗率可选择为(0.1~1)%即可。 对于用于限制高次谐波放大的串联电抗器。其感抗值的选择应使在可能产生的任何谐波下,均使电容器回路的总电抗为感性而不是容性,从而消除了谐振的可能。电抗器的感抗值按下列计算: X L =K X C n 2 式中 X L ——串联电抗器的感抗,Ω; X C ——补偿电容器的工频容抗, Ω;

无功补偿柜电容器的容量换算问题

在无功补偿领域,我们经常会问的一句话是:电容器容量是多少? 这里的“容量”又指电容器的额定容量,其实是指电容器的功率,单位用kvar(千乏)来表示。 专业知识普及 从下面这个公式可以看出电容器的功率与电压的关系: Q=2πfCU2 Q表示电容器的功率,单位var f表示系统频率,50Hz/60Hz C为电容器容量,单位uF(微法) U表示系统电压,单位kV(千伏) 由上面表达式可以看出,电容器的功率与施加到电容器两端 的电压平方成正比。 每一只电容器都有一个参数叫做额定电压,对应额定电压则有一个额定功率。 例如:选择电压为450V,额定功率为30kvar的电容器。 问1:当额定电压为450V,额定功率为30kvar的电容器,用在400V 系统中,其输出功率为多少呢? 这就是我们经常碰到的问题,电容器的额定电压都是高于系统的额定电压的。

通过上面的公式,我们可以很快算出来: Q400=Q450×(4002/4502) =30×(4002/4502) ≈23.7 kvar 问2:为什么要选择额定电压高于系统电压的电容器呢? 电容器经受过电压危害时将快速损坏。为了保障电容器的运行安全,需要选择额定电压大于系统电压的电容器。 到这个阶段我们知道了,如果无功补偿支路设计为纯电容器的话,无功补偿支路的输出功率要根据电容器的额定电压和系统电压进行折算。这也就是我们常说的安装功率(安装容量)和输出功率(输出容量)。 安装功率常指电容器的额定功率; 输出功率常指电容器在系统电压下的实际输出功率。 参照上面举例,我们可以知道:将额定电压为450V,30kvar的电容器应用于400V无功补偿系统,则此系统安装容量为30kvar,其输出容量为23.7kvar。 问3:当电容器串联电抗后,电容器与电抗器组成的补偿支路功率是多少呢?

电容补偿柜的电容容量如何计算

电容补偿柜的电容容量如何计算 电容补偿柜的电容容量如何计算?(此文章讲的很透彻,很好的一篇文章)电网中由于有大功率电机的存在,使得其总体呈感性,所以常常在电网中引入大功率无功补偿器(其实就是大电容),使电网近似于纯阻性,Kvar就常用在这作为无功补偿电容器的容量的单位。 补偿电容器:主要用于低压电网提高功率因数,减少线路损耗,改善电能质量 电容器容量的换算公式为(指三相补偿电容器): Q=√3×U×I ; I=×C×U/√3 ; C=Q/×U×U) 上式中Q为补偿容量,单位为(Kvar),U为额定运行电压,单位为(KV),I为补偿电流,单位为(A),C为电容值,单位为(F)。式中=2πf/1000。 1. 例如:一补偿电容铭牌如下: 型号: , 3: 三相补偿电容器; 额定电压:; 额定容量:10Kvar ; 额定频率:50Hz ; 额定电容:199uF (指总电容器量,即相当于3个电容器的容量)。额定电流: 代入上面的公式,计算,结果相符合。 2. 200KVA变压器无功补偿柜匹配电容多少最合理? 一般来说,对于电动机类型的功率负荷,补偿量约为40%,对于综合配电变压器,补偿量约为20%. 如果知道未补偿前的功率因数,那么根据公式即可以算出具体的补偿量。 3. 例如:有电机12台,的电机4台,11KW的电机2台,500型电焊机15台,由于有用电高峰和低谷,在低谷时动力可下降30%,我现在用无功补偿柜里的电容器有4块14Kvar的,6块40Kvar的。据说匹配不合理,怎么样才能匹配合理。另外补偿器的读数在多少时最合适时没有罚款有奖励。 一般来说,配电变压器的无功补偿容量约为变压器容量的20%~40%,对于200KVA的配电变压器,补偿量约为40Kvar~80Kvar。准确计算无功补偿容量比较复杂,且负荷多经常变化,计算出来也无太大意义。一般设计人员以30%来估算,即选取60Kvar为最大补偿容量,也就是安装容量。电容器补的太少,起不到多大作用,需要从网上吸收无功,功率因数会很低,计费的无功电能表要“走字”,记录正向无功;电容器补的太多,要向网上送无功,网上也是不需要的,计费的无功电能表也要“走字”,记录反向无功;供电企业在月底计算电费时,是将正

电力电容器及无功补偿技术手册

电力电容器及无功补偿 技术手册 沙舟编著

目录 前言 第一章基本概念 (1) §1-1 交流电的能量转换 (1) §1-2 有功功率与无功功率 (2) §1-3 电容器的串联与并联 (3) §1-4 并联电容器的容量与损耗 (3) §1-5 并联电容器的无功补偿作用 (4) 第二章并联电容器无功补偿的技术经济效益 (5) §2-1 无功补偿经济当量 (5) §2-2 最佳功率因数的确定 (7) §2-3 安装并联电容器改善电网电压质量 (8) §2-4 安装并联电容器降低线损 (11) §2-5 安装并联电容器释放发电和供电设备容量 (13) §2-6 安装并联电容器减少电费支出 (15)

前言 众所周知,供电质量主要决定于电压、频率和波形三个方面。电网频率稳定决定于电网有功平衡,波形主要决定于网络和负荷的谐波,电压稳定则决定于无功平衡。当然三者之间也具有一定的内在关系。无功平衡决定于网络中无功的产生和消耗。在系统中无功电源有同步发电机、同步调相机、电容器、电缆、输电线路电容、静止无功补偿装置和用户同步电动机,无功负荷则有电力变压器,输电线路电感和用户的感应电动机,各种感应式加热炉、电弧炉等。为了满足系统中无功电力的需求,单靠发电机、调相机、电缆和输电线路电容是不够的,静补装置中也是采用电容器等。因此电容器在系统的无功电源中占有相当比重,加之调相机为旋转设备。建设投资大,运行维护费用高。近年来世界各国都积极装设电容器,满足系统无功电力要求,维持电压稳定。但各国主要是装设并联电容器,装串联电容器者较少,因此编者主要介绍并联电容器无功补偿技术,它还广泛应用于谐波滤波装置,动态无功补偿设备和电气化铁道无功补偿装置之中,因与电力系统谐波有关。限于篇幅,准备在“谐波技术”中详述。这里主要介绍一些无功补偿技术基础。限于编者水平,加上时间仓促,不当之处难免,请读者批评指正。

并联电容器对电力系统无功补偿及电压调节问题的探讨_马文成

DOI :10.3969/j.issn.1001-8972.2012.09.069 并联电容器对电力系统无功补偿及电压调节问题的探讨 马文成 固原供电局,宁夏 固原 756300 摘 要 变电站并联电容器可以对电网的无功功率进 行集中补偿。通过对无功功率的合理补偿, 从而达到调节电压、使系统经济和稳定运 行。但在实际运行中,往往由于设计原因, 无功负荷的分布不可预见性等因素导致变电 站母线并联电容器不能合理的补偿无功和调 节电压。下面就某站10kV 母线并联电容器运 行中存在的问题加以分析和探讨。 关键词 并联电容器;无功补偿;电压调节 某变电站电压等级为110/35/10kV ,两台 主变容量分别为25000kVA 和20000kVA 的有载调 压变压器,正常时20000kVA 变压器运行,另一 台主变热备用,10kV Ⅰ、Ⅱ段母线经分段开关 联成单母运行。10kV Ⅱ段母线装TBB 210- 3600/3600Kvar 成套电容器装置,电容器型号 为:BFFH 4-11/ -2×1800-1×3W 密集型电 容器,每组容量为1800Kvar ,两组共 3600Kvar ,其额定电流为89A ,串联电抗器型 号为CKGKL-12/10-1的空芯电抗器,额定电 抗率为1%。 1 运行中存在的问题 该站自2000年投运以来,因10kV 母线并联 电容器的补偿容量不合理致使电容器不能正常 投入运行,因此,10kV 母线输送的无功负荷不 能实现就地补偿,从而不利于电网运行的经济 性和稳定性。 1.1 并联电容器投入时补偿容量过剩 图例分析如下: 图1 上图数据为该站10kV 母线2011年有功、无 功负荷平均值,从图中可以看出,10kV 母线 年输送无功负荷最大值为1500Kvar ,最小值为 500Kvar ,平均值为1000Kvar 。若投入一组容量 为 的电容器时除补偿了10kV 母线输送的无功 负荷外,还向系统倒送无功容量800Kvar 。按照 规定,电力系统无功补偿应以分级补偿,就地 平衡的原则进行,向系统倒送无功时将会引起 过电压,系统稳定性受到破坏。因此,向系统 倒送无功是不允许的。 1.2 并联电容器投入时对母线电压影响较 大 若正常运行时投入一台20000kVA 的有载调 压变压器时,从图A 中可知10kV 母线年输送有 功功率最大值为6000kW ,最小值为3000kW , 平均值为4500kW 。正常运行时,在110kV 母线 确保电压合格率的情况下,35kV 及10kV 母线 通过有载调压完全可以满足各级母线电压合格 率的要求。当电容器投入时,除补偿了10kV 母线输送的无功功率外,还向系统倒送了大量 无功。此时,变压器输出的无功功率减少,导 致高压侧母线向系统输送的无功减少而电压升 高。变压器中、低压侧母线电压随之相应升 高,尤其低压侧母线电压升高较大,而并联电 容器运行时向系统补偿的无功容量与其端电压 的平方成正比,电压升高浮度越大,向系统输 送的无功容量越大,如此恶性循环,可能导致 电容器过电压保护动作跳闸,系统其它设备超 过额定电压运行时,其绝缘受到威胁。此时, 用有载调压来降低电压运行已不能满足电压合 格率的要求。 1.3 并联电容器退出运行时对系统经济运 行的影响 变电站并联电容器投入电网的目的是为 了补偿系统无功的不足,减少电源向系统输送 的无功功率,从而提高有功输送容量。因电源 向系统远距离输送无功负荷时,在线路及变压 器等感性、容性元件及阻性元件上消耗一定的 有功功率,因此,电源远距离大容量输送无功 不经济。变电站采用并联电容器通过就地无功 补偿,可以降低电源向系统及用户输送的无功 负荷,从而提高了有功输送容量。相对于电源 输送无功时,变电站并联电容器的单位容量费 用最低,有功功率损耗最小(约为额定容量的 0.3%~0.5%),一次性投资,运行维护简便。 因此用系统减少输送的无功功率来相应的提高 有功容量的输送能力,从经济性方面比较, 并联电容器投资成本小,最多1~2年可收回成 本。因此,获得了最好的经济效益。 从以上分析可以看出,当该站并联电容器 退出运行时,据查10kV 母线年输送无功电能约 760万度。因此,在当前负荷情况下,并联电容 器退出运行最不经济。 2 应采取的措施 针对以上分析,该站10kV 母线并联电容器 在电压调整、无功补偿过剩及运行经济性方面 存在着相互制约的矛盾,如何解决这一问题, 本人提出采取以下措施: 2.1 改变10kV 母线并联电容器的接线方 式,改造图如下: 图2 图3 图2为原接线,改造前当一组电容器投 入运行时向系统输送的总无功补偿容量为 Q 1=U 2ωC ,式中:U 为母线端电压,当f 为工 频时,ω为一常数,C 1=C 2,因C 1和C 2并联, 所以C=C 1+C 2,即Q 1=2U 2ωC 1。图C 为改造后 的接线图,总无功补偿容量为Q 2=U 2ωC ,式 中:U 为母线端电压,当f 为工频时,ω为一 常数,C 1=C 2,因C 1和C 2串联,所以C=C 1/2, 即Q 2=U 2ωC 1/2。所以 Q 1/Q 2=2U 2ωC 1/ U 2ωC 1/2=4,即Q 2=Q 1/4=3600/4=900(Kvar)。 通过计算可知,改造后两组电容器串联后 再三相并联接于电网时的总无功功率900Kvar 。 考虑到后期无功负荷的增长给补偿带来新 -119- 的问题,上述改造中在实际设备上可通过如图 C 所示加装一组隔离开关来实现,即通过操作 拉开G 2隔离开关,合上G 1隔离开关来实现投入 无功容量900Kvar 。后期无功负荷增长较大时, 可通过操作拉开G 1隔离开关,合上G 2隔离开关 来实现投入无功容量 1800Kvar 。 2.2 改变并联电容器的接线方式后对系统 及各元件的影响 2.2.1 对系统的无功补偿情况 图A 中,按目前年平均输送无功负荷曲线 可以看出,年平均无功输送容量为1000Kvar , 改造后并联电容器投入电网运行时补偿的无功 容量为900Kvar ,因此,可以实现就地补偿无 功的能力。对于后期无功负荷增长带来的无功 补偿不足时,可通过操作 G 1、G 2隔离开关来实 现电容器无功容量在900Kvar 与1800Kvar 之间转 换。 2.2.2 对电压质量的影响 改造后并联电容器输送的总无功容量为改 造前的一半,因此电容器投入运行时对电压的 影响相对较小,当各级母线电压变化时可通过 变压器有载调压装置调整电压,以及无功补偿 情况投退并联电容器来调整电压。 2.2.3 改造后的并联电容器运行时的经济 性 通过无功就地平衡补偿,据查可实现年累 计补偿无功负荷约760万度,相对电源系统输送 无功来说,可减少网损,提高电源输送能力, 最终达到经济效益最大化。 2.2.4 改造后对成套并联电容器装置各元 件的影响 2.2.4.1 对电容器各参数的影响 电容器额定电压为11/ kV ,改造后C1和 C2串联,当接在10kV 母线上时,C1和C2 串联 时分压,即C1与C2各承受电压为改造前端电压 的 一 半 , 电 容 器 通 过 的 电 流 为 I=Q2/2U=900/2×10=45(A)。因此,改造后的 各电容器承受的电压和通过的电流均在额定参 数内。 2.2.4.2 对电抗器的影响 因电抗器额定电压为10kV ,额定电流为 189A ,改造后均在额定值范围内。 2.2.4.3 对继电保护的影响 当并联电容器主接线改变后,其输送的电 流和各电容器承受的电压相应的发生变化,因 此,原保护定值不能满足需要,应重新计算并 整定,即可通过现有微机保护整定两套定值, 当电容器的无功容量在900Kvar 与1800Kvar 之间 转换时,切换相应的定值实现保护功能。 笔者认为通过上述改造后,可解决该站目 前10kV 母线无功负荷的补偿问题,从而实现了 该站并联电容器长时间不能投入电网运行的难 题,同时,提高了10kV 系统的功率因数,优化 了电网运行方案,提高了系统运行的经济性。 参考文献 [1] 韩祯祥,吴国炎 .电力系统分析. 浙江大学出 版社, 2002年版,227页 [2] 李坚,郭建文 .变电运行及设备管理技术问 答.中国电力出版社 ,2005年版,158页 作者简介 马文成 学历:大学 职称:工程师。

无功补偿考试试题 (1)

一单项选择(共10道) 1 《并联电容器装置设计规范》GB50227-2008适用于(A )kV及以下电压等级的变电站、配电站中无功补偿用三相交流高压、低压并联电容器装置的新建、扩建工程设计。 (A)750(B)220 (C)110(D)35 2电抗率是指并联电容器装置的( C )之比,以百分数表示。 (A)串联电抗器的额定容抗与串联连接的电容器的额定感抗 (B)串联连接的电容器的额定容抗与串联电抗器的额定感抗 (C)串联电抗器的额定感抗与串联连接的电容器的额定容抗 (D)串联连接的电容器的额定感抗与串联电抗器的额定容抗 3每个串联段的电容器并联总容量不应超过( B )kvar。 (A)4200(B)3900 (C)2300 (D)1200 4 并联电容器装置总回路和分组回路的电器导体选择时,回路工作电流应按稳态过电流最大值确定,过电流倍数应为回路额定电流的(C )倍。 (A)1.1 (B)1.2 (C)1.3(D)1.5 5用于单台电容器保护的外熔断器的熔丝额定电流,应按电容器额定电流的(C )倍选择。 (A)0.83--0.95 (B)0.95--1.12 (C)1.37--1.50(D)2--5 6 并联电容器装置的放电器件应满足电容器断电后,在5s内将电容器的剩余电压降至(C )V及以下。(A)380(B)220 (C)50(D)36 7动态无功补偿装置SVC自身产生的3、5、7、11次谐波,采用角型接线,其中( C )次谐波不会流入系统。 (A)5(B)7 (C)3 (D)11 8、计算电容器额定电压是,需要考虑哪些因素(A B C) (A)系统额定电压(B)串联电抗器引起的电压抬升 (C)谐波引起的电压抬升(D)电容器内部元件额定电压 9、110kV系统允许的电压总畸变率为(C) (A)1.6% (B)2.0% (C)2.4% (D)3.0% 10、电能质量对频率指标有严格的要求,系统频率主要取决于(B) (A)有功(B)无功(C)电压(D)电流 二填空题(共10道) 1、电力系统无功电源主要有同步调相机、同步发电机、电力电容器、静止无功发生器。 2、电容器成套装置一般由高压并联电容器、串联电抗器、隔离开关、电流互感器、避雷器以及其余附件组成。 3、并联电容器成套装置回路中串联电抗器的作用是抑制谐波和限制合闸涌流。 4、TCR型静止动态无功补偿装置一般具有热管自冷、水冷两种冷却方式。 5、电力电子元器件串联使用要解决均压问题,并联使用要解决均流问题,目前最常用的均压方式为在元器件两端并联RC均压回路。 6、静止无功发生器SVG一般具有空载、感性、容性三种运行方式。 2U。三相半波可控整流电路中,晶闸管承受7、单相全波可控整流电路中,晶闸管承受的最大反向电压为2 6U。(电源相电压为U2) 的最大反向电压为2 8、磁控型动态无功补偿装置其励磁方式一般分为内励磁和外励磁两种方式。 9、电能质量指标主要包括电压、电流、波形和畸变率。

并联电容器设计要求规范

并联电容器装置设计规范(GB50227-95) 第一章总则 第1.0.1条为使电力工程的并联电容器装置设计贯彻国家技术经济政策, 做到安全可靠、技术先进、经济合理和运行检修方便,制订本规范. 第1.0.2条本规范适用于220KV及以下变电所、配电所中无功补偿用三相交流高压、低压并联电容器装置的新建、扩建工程设计. 第1.0.3条并联电容器装置的设计, 应根据安装地点的电网条件、补偿要求、环境状况、运行检修要求和实践经验,确定补偿容量、选择接线、保护与控制、布置及安装方式. 第1.0.4条并联电容器装置的设备选型, 应符合国家现行的产品标准的规定. 第1.0.5条并联电容器装置的设计,除应执行本规范的规定外,尚应符合国家现行的有关标准和规范的规定. 第二章-1 术语 1.高压并联电容器装置 (installtion of high voltage shunt capacitors): 由高压并联电容器和相应的一次及二次配套设备组成, 可独立运行或并联运行的装置. 2.低压并联电容器装置 (installtion of low voltage shunt capacitors): 由低压并联电容器和相应的一次及二次配套元件组成, 可独立运行或并联运行的装置. 3.并联电容器的成套装置 (complete set of installation for shunt capacitors): 由制造厂设计组装设备向用户供货的整套并联电容器装置. 4.单台电容器(capacitor unit): 由一个或多个电容器元件组装于单个外壳中并引出端子的组装体. 5.电容器组(capacitor bank): 电气上连接在一起的一群单台电容器. 6.电抗率(reactance ratio): 串联电抗器的感抗与并联电容器组的容抗之比,以百分数表示.

用并联电容器补偿无功功率的原理及相关方法

用并联电容器补偿无功功率的原理及相关方法 无功补偿的原理:电网输出的功率包括两部分;一是有功功率;二是无功功率.直接消耗电能,把电能转变为机械能,热能,化学能或声能,利用这些能作功,这部分功率称为有功功率;不消耗电能;只是把电能转换为另一种形式的能,这种能作为电气设备能够作功的必备条件,并且,这种能是在电网中与电能进行周期性转换,这部分功率称为无功功率,如电磁元件建立磁场占用的电能,电容器建立电场所占的电能.电流在电感元件中作功时,电流超前于电压90℃.而电流在电容元件中作功时,电流滞后电压90℃.在同一电路中,电感电流与电容电流方向相反,互差180℃.如果在电磁元件电路中有比例地安装电容元件,使两者的电流相互抵消,使电流的矢量与电压矢量之间的夹角缩小,从而提高电能作功的能力,这就是无功补偿的道理. 集中补偿电容器作为补偿装置有两种方法:串联补偿和并联补偿。串联补偿是把直接串联到高压输电线路上,以改善输电线路参数,降低电压损失,提高其输送能力,降低线路损耗。这种补偿方法的电容器称作串联电容器,应用于高压远距离输电线路上,用电单位很少采用。并联补偿是把电容器直接与被补偿设备并接到同一电路上,以提高功率因数。这种补偿方法所用的电容器称作并联电容器,用电企业都是采用这种补偿方法。按电容器安装的位置不同,通常有三种方式。 1.集中补偿电容器组集中装设在企业或地方总降压变电所的6~10kV母线上,用来提高整个变电所的功率因数,使该变电所的供电范围内无功功率基本平衡。可减少高压线路的无功损耗,而且能够提高本变电所的供电电压质量。

2.分组补偿将电容器组分别装设在功率因数较低的车间或村镇终端所高压或低压母线上,也称为分散补偿。这种方式具有与集中补偿相同的优点,仅无功补偿容量和范围相对小些。但是分组补偿的效果比较明显,采用得也较普遍。 3.就地补偿将电容器或电容器组装设在异步或电感性用电设备附近,就地进行无功补偿,也称为单独补偿或个别补偿方式。这种方式既能提高为用电设备供电回路的功率因数,又能改善用电设备的电压质量,对中、小型设备十分适用。

补偿电容器运行规程

补偿电容器运行规程 1.一般规定 1.1 并联补偿电力电容器组必须装设单台保护装置、过电流保护装置、过电压保护和失压保护装置。 1.2 单台保护装置可用以下方法实现 1.2.1 单台熔丝; 1.2.2 单三角接线的零序保护; 1.2.3 单星形接线的中点电流平衡保护; 1.2.4 双三角接线的差流保护; 1.2.5 双星形接线的中点平衡或电压平衡保护; 1.2.6 相由几台串联而成时,串联元件差压或元件过电压保护或H型接线平衡保护; 1.2.7 单台熔丝可与其它五种保护之一配合时采用,其它五种保护根据一次接线只采用其中一种。 1.3 采用内熔丝电容器时,不必装设单台熔丝。而采用第1.2条规定的单台保护,每串联段的过电压保护,但仍应有整流过压及失压保护。 1.4 用熔丝保护时,必须使用专用熔断器与专用熔丝,熔丝额定电流为单台电容器额定电流1.3~1.5倍。 1.5 当同一变电站同一母线上(或同一电压并列运行的两段母线上)装有两组及以上电容器时,为限制合闸涌流,必须装设串联电抗器,

如安装地点有高次谐波,为限制高次谐波电流也应装设串联电抗器。对无高次谐波,仅为限制合闸涌流时,串联电抗器可按2%选择,对限制高次谐波电流的串联电抗器,根据谐波次数来决定,为限制三次谐波时串联电抗器应选13%,五次谐波6%,七次谐波3%。 1.6 防止切除电容器时,开关电弧重燃过电压,电容器母线上应单独装设避雷器和放电记录器,所用避雷器尽量采用性能较好的氧化锌避雷器。 1.7 容器组尽量配有专门的放电线圈,无专门放电线圈时,电压互感器作放电回路但要验标。 1.8 由于电容器始终在满负荷下运行,电容器回路的开闭回路设备,互感器,铝母线和电缆载面宜有较大裕度,一般情况下,互感器额定电流应为电容器电流1.5~2倍。电缆和母线载面按经济电流密度选择。 1.9 对于投切较频繁(在运行期间,每日至少投切一次)的电容器组或单组容量为3000千乏以上时必须采用真空开关控制切投不频繁(如投入运行后,在一定时间内不退出的)以及单组容量小于3000千乏时,允许采用SN10—10型开关来控制,但无论用何种开关,遮断容量符合安装地点短路容量的要求。 1.10 投切较频繁的电容器组(指每天投切两次以上的),尤其是分组投切的多组电容器一般应安装自动切投装置,自动投切装置可按以下原则投切。 1.10.1 按固定时间自动投切;

无功功率补偿并电容器

题目:无功功率补偿和并联电容器

目录 第一章绪论 (3) 1.1研究背景 (3) 1.2无功装置的发展状况 (4) 第二章无功补偿的原理 (5) 2.1无功补偿的原理 (5) 2.2无功补偿的意义 (5) 2.3确定容量的一般方法 (7) 2.4无功补偿装置的选择 (8) 第三章无功补偿的投切方式 (9) 3.1无功补偿的投切器件 (9) 3.2瞬时投切方式 (10) 第四章并联电容器 (12) 4.1并联电容器简介 (12) 4.2使用电容器的优点 (12) 4.3并联电容器无功补偿的配置方法 (13) 4.4电容器的安装要求 (13) 4.5并联电容器的日常维护 (14) 4.6电容器组投入和退出运行 (15) 4.7例子 (15) 第五章总结 (20)

第一章绪论 1.1研究背景 目前,我国的电网,特别是广大的低压电网,普遍存在功率因数较低,电网线损较大的情况。导致此现象的主要原因是众多的感性负载用电设备设计落后,功率因数较低,比如我国的电动机消耗的电能占全部发电量的70%,而由于设计和使用方面的原因我国的电动机的功率因数往往较低,一般约为 cos=0.70。 在这种情况下,采用无功补偿节能技术,对提高电能质量和挖掘电网潜力是十分必要的,世界各国都把无功补偿作为电网规划的重要组成部分。从我国电网功率因数和补偿深度来看,我国与世界发达国家有不小的差距。因此大力推广无功补偿技术是非常必要的,世界各国都把无功补偿作为电网规 划的重要组成部分。从我国电网功率因数和补偿深度来看,我国与世界发达国家有不小差距。因此大力推广补偿技术是非常必要的,并且从以下数据,我们也能看出无功补偿所能带来的巨大经济效益。2007年,我国年总发电量为32559亿千瓦时,统计线损率为8.77%,但是这个数字没有包含相当大的 110千伏、35千伏、10千伏的输电线损及0.38千伏的低压电网线损。据报 道,估计实际的统计线损率约为15%,即2007年全国年线损量约为4800亿 千瓦时,设全国的理论线损与统计线损相一致,其中可变线损约占理论总线损的80%,则每年可以降低线损约为300亿千瓦时。设当前全国电力网总负 荷的当前功率因数cos=0.85,采用无功功率补偿后,把电力网总负荷的功率因数提高到cos=0.95,则每年可以降低线损约为390亿千瓦时,按0.5 元每千瓦时计,价值约为185亿元,设2007年全国电网的最大负荷利用小 时数为5000小时,则电网的最大负荷约为2亿千瓦时,当用无功功率补偿 法把功率因数cos=0.85,提高到cos=0.95,全国电网需总补偿总量约为 0.58亿千瓦。当前无功功率补偿装置设备主要为电力电容器,设无功补偿设 备每千瓦的平均综合造价为50元,则全国无功补偿装置的总投资约为29亿元。应当指出,节省240亿千瓦时约相当于一座400万千瓦火电厂的年发电量,而建一座400万千瓦的火电厂需综合费用约为300亿元,同时每年需燃 烧煤约为1200万吨,每年产生CO 2和SO 2 等有害物质约为600万吨。由此可 见,产生相同的电力,无功补偿的费用越为新建电厂费用的10%,而且无功补偿设备的费用仅需两个月的无功功率补偿的将损节电费用即可全部收回。 综上所述,无功补偿不仅具有如上述的节省投资、节省电力、节省燃料及污染等作用,同时还可以提高电力系统设备的供电能力,改善电压质量,

并联电容器无功补偿及其正确使用

并联电容器无功补偿及其正确使用 异步电动机的无功就地补偿技术,近些年来得到推广应用。就地补偿方式的主要优点是:所需设备少,投资少,运行可靠,维护方便,特别对单机容量较大,运行时间长,距离电源较远的电动机更为适用。它对减少企业电能损失,提高电压质量有重大意义。采用并联电容器进行无功补偿,其主要作用是:1、补偿无功功率,提高功率因数;2、提高设备出力;3、降低功率损耗和电能损失;4、改善电压质量。一般工矿企业要求功率因数必须大于0.9,为提高功率因数常采用变电所集中补偿和就地补偿或两者结合使用。无功补偿容量按下式计算:Q=P(tgθ1—tgθ2),其中tgθ1、tgθ2为补偿前后的正切值,在补偿前后,由于有功功率不变,有功功率损耗值也无改变,但是,无功功率发生了变化,由Q降低为Q—Q C,故通过输、变配、用电设备有效电阻R时,有功功率的损耗由降低为ΔP2Q,所以并联电容器补偿的经济当量为K C=ΔP1Q—ΔP2Q=[Q2/U2*10-3—(Q-Q C)2/U2*R*10-3]/ Q C=(2Q- Q C)/ U2Q(2- Q C/Q)=ΔP1Q/Q(2- Q C/Q),可见采取并联电容器补偿的经济当量的大小取决于补偿容量与无功功率的比值。并且还表明,K C与两个因素有关:一是与ΔP1Q/Q成正比,二是与(2- Q C/Q)成正比。由于Q C可大可小,从自身效益和社会效益整体来考虑,多少合适,这是一个值得研究的问题。(1)、当Q C《Q时,2- Q C/Q≈2,这种情况等于没有补偿,谈不上降低有功功率的损耗。(2)、当Q C≈Q 时,2- Q C/Q≈1,这种情况等于全补偿,因负荷的变化,有时会出现

电容补偿计算方法完整版

电容补偿计算方法 Document serial number【NL89WT-NY98YT-NC8CB-NNUUT-NUT108】

1、感性负载的视在功率S×负载的功率因数COSφ = 需要补偿的无功功率Q: S×COSφ =Q 2、相无功率Q‘ = 补偿的三相无功功率Q/3 3、因为:Q =2πfCU^2 ,所以: 1μF电容、额定电压380v时,无功容量是Q= 100μF电容、额定电压380v时,无功容量是Q= 1000μF电容、额定电压380v时,无功容量是Q=45Kvar 4、“多大负荷需要多大电容” : 1)你可以先算出三相的无功功率Q; 2)在算出1相的无功功率Q/3; 3)在算出1相的电容C; 4)然后三角形连接!

5、因为:Q =2πfCU^2 ,所以: 1μF电容、额定电压10Kv时,无功容量是Q= 100μF电容、额定电压10Kv时,无功容量是Q=3140Kvar 6、因为:Q =2πfCU^2 ,所以: 1μF电容、额定电压220v时,无功容量是Q= 100μF电容、额定电压220v时,无功容量是Q= 1000μF电容、额定电压220v时,无功容量是Q= 提高功率因数节能计算 我这里有一个电机,有功功率 kw 视在功率 kva 无功功率 kvar 功率因数cosφ= 电压是377V 电流是135A 麻烦帮我算一下功率因数提高到所节约的电能,以及需要就地补偿的电容容量,请给出公式和注意事项,感谢! 满意答案 网友回答2014-05-03 有功功率是不变的,功率因数提高到以后,无功功率降低为Q=P*tgφ= P*tg(arcosφ)=P*tg=*= 需补偿容量为 视在功率也减小为P/cosφ==所节约的电能是不好计算的,因为电能是以有

低压配电并联电容器补偿回路所串电抗器的合理选择

低压配电并联电容器补偿回路所串电抗器的合理选择 一、前言 在笔者所接触的低压配电施工图中,发现施工图中有一个共性,那就是配电变压器低压侧母线上均接入无功补偿电容器柜。但令人费解的是,所串电抗器无任何规格要求,无技术参数的注明,只是在图中画了一个电抗器的符号而已。而所标电容器的容量,也只是电容器铭牌容量而已,实际运行时,最大能补偿多少无功功率,也不得而知。 应引起注意的是,电抗器与电容器不能随意组合,它要根据所处低压电网负荷情况,变压器容量,用电设备的性质,所产生谐波的种类及各次谐波含量,应要进行谐波测量后,才能对症下药,决定电抗器如何选择。但往往是低压配电与电容补偿同期进行,根本无法先进行谐波测量,然后进行电抗器的选择。退一步说,即使电网投入运行,进行谐波测量,但用电设备是变动的,电网结构也是变化的,造成谐波的次数及大小有其随意性,复杂性。因此正确选用电容器所用的串联电抗器也成为疑难问题,这无疑是一个比较复杂的系统工程,不是随便一个电抗器的符号或口头说明要加电抗器那么简单了。不得随意配合,否则适得其反,造成谐波放大,严重时会引发谐振,危及电容器及系统安全,而且浪费了投资。有鉴于此,笔者对如何正确选用电容器串联电抗器的问题,将本人研究的一点心得,撰写成文,以候教于高明。 二、电力系统谐波分析及谐波危害 电力系统产生谐波的原因主要是用电设备的非线性特点。所谓非线性,即所施电压与其通过的电流非线性关系。例如变压器的励磁回路,当变压器的铁芯过饱和时,励磁曲线是非正弦的。当电压为正弦波时,励磁电流为非正弦波,即尖顶波,它含有各次谐波。非线性负载的还有各种整流装置,电力机车的整流设备,电弧炼钢炉,EPS,UPS及各种逆变器等。目前办公室里电子设备很多,这里存在开关电源及整流装置,其电流成分也包含有各次谐波,另外办公场所日光灯及车间内各种照明用的气体放电灯,它们也是谐波电流的制造者。日光灯铁芯镇流器及过电压运行的电机也是谐波制造者。 目前所用的配电变压器高压侧多接成“Δ”型,这样三次谐波因相序相同,即零序的感应的三次谐波电流在三角形绕组内环流,不易窜入电网。磁路过饱和而产生的谐波类似六脉动整流回路,主要产生6K±1次谐波,多为5次,7次,11次等。据有关人员实测表明,电力机车及电弧炉供电系统3次谐波较多,而办公楼及普通工厂车间5次与7次谐波为主。由于低压配电不涉及电弧炉及电力机车,这样矛盾的焦点集中于5次谐波治理抑制上了。

电容补偿计算方法

1、感性负载的视在功率S×负载的功率因数COSφ = 需要补偿的无功功率Q: S×COSφ =Q 2、相无功率Q‘ =? 补偿的三相无功功率Q/3 3、因为:Q =2πfCU^2 ,所以: 1μF电容、额定电压380v时,无功容量是Q=0.045Kvar 100μF电容、额定电压380v时,无功容量是Q=4.5Kvar? 1000μF电容、额定电压380v时,无功容量是Q=45Kvar 4、“多大负荷需要多大电容” : 1)你可以先算出三相的无功功率Q; 2)在算出1相的无功功率Q/3; 3)在算出1相的电容C; 4)然后三角形连接! 5、因为:Q =2πfCU^2 ,所以: 1μF电容、额定电压10Kv时,无功容量是Q=31.4Kvar 100μF电容、额定电压10Kv时,无功容量是Q=3140Kvar 6、因为:Q =2πfCU^2 ,所以: 1μF电容、额定电压220v时,无功容量是Q=0.015Kvar 100μF电容、额定电压220v时,无功容量是Q=1.520Kvar? 1000μF电容、额定电压220v时,无功容量是Q=15.198Kvar

提高功率因数节能计算 我这里有一个电机,有功功率 kw 23.3 视在功率 kva 87.2 无功功率 kvar 84.1 功率因数cosφ=0.27 电压是377V 电流是135A 麻烦帮我算一下功率因数提高到0.95所节约的电能,以及需要就地补偿的电容容量,请给出公式和注意事项,感谢! 满意答案 网友回答2014-05-03 有功功率23.3KW是不变的,功率因数提高到0.95以后,无功功率降低为Q=P*tgφ= P*tg(arcosφ)=P*tg(arcos0.95)=23.3*0.33=7.7kvar 需补偿容量为84.1-7.7=76.4kvar 视在功率也减小为P/cosφ=23.3/0.95=24.5kva 所节约的电能是不好计算的,因为电能是以有功电量计算的,但功率因数提高了,你的力率电费会减少,能少交很多电费。 另外,因为视在功率降低了,线路上的电流也就降低了,线路损耗也能相应降低不少,电压也会有所提高。。 电动机无功补偿容量的计算方法 有以下两种: 1、空载电流法 Qc=3(Uc2/Ue2)*Ue*Io*K1。 说明: I0——电动机空载电流; Uc——电容器额定电压(kv); Ue——电动机额定电压; K1——推荐系统0.9。 2、目标功率因数法 Qc=P(1/(cosφe2-1)-1/(cosφ2-1))*K2。 说明:cosφe——电动机额定功率因数; K2——修正系数; cosφ ——电动机补偿后的目标功率因数; P——电动机额定功率; Ue——电动机额定电压; 推荐cosφ在0.95~0.98范围内选取。

相关主题
文本预览
相关文档 最新文档