当前位置:文档之家› 重庆三峡水利电力盈利能力分析(1)

重庆三峡水利电力盈利能力分析(1)

重庆三峡水利电力盈利能力分析(1)
重庆三峡水利电力盈利能力分析(1)

重庆三峡水利电力(集团)股份有限公司

盈利能力指标

盈利能力指标主要包括营业利润率、成本费用利润率、总资产报酬率、净资产收益率和资本收益率六项。

1、营业利润率

2011、

营业利润率=营业利润/营业收入×100%=%

销售毛利率=(销售收入-销售成本)/销售收入×100%=%

销售净利率=净利润/销售收入×100%=%

2012、

营业利润率=营业利润/营业收入×100%=%

销售毛利率=(销售收入-销售成本)/销售收入×100%=%

销售净利率=净利润/销售收入×100%=%

2013、

营业利润率=营业利润/营业收入×100%=%

销售毛利率=(销售收入-销售成本)/销售收入×100%=%

销售净利率=净利润/销售收入×100%=%

2014、

营业利润率=营业利润/营业收入×100%=%

销售毛利率=(销售收入-销售成本)/销售收入×100%=%

销售净利率=净利润/销售收入×100%=%

2、成本费用利润率

2011、成本费用利润率=利润总额/成本费用总额×100%=% 2012、成本费用利润率=利润总额/成本费用总额×100%=% 2013、成本费用利润率=利润总额/成本费用总额×100%=% 2014、成本费用利润率=利润总额/成本费用总额×100%=%

3、总资产报酬率

2011总资产报酬率=息税前利润总额/平均资产总额×100%=% 2012总资产报酬率=息税前利润总额/平均资产总额×100%=% 2013总资产报酬率=息税前利润总额/平均资产总额×100%=%

2014总资产报酬率=息税前利润总额/平均资产总额×100%=%

4、净资产收益率

2011、净资产收益率=净利润/平均净资产×100%=% 2012、净资产收益率=净利润/平均净资产×100%=% 2013、净资产收益率=净利润/平均净资产×100%=% 2014、净资产收益率

=净利润/平均净资产×100%=%

5、每股收益

2011、每股收益=净利润/发行在外的股票数量= 2012、每股收益=净利润/发行在外的股票数量= 2013、每股收益=净利润/发行在外的股票数量= 2014、每股收益=净利润/发行在外的股票数量=

6、每股净资产

2011、每股净资产=年末股东权益/年末普通股总数= 2012、每股净资产=年末股东权益/年末普通股总数=4. 2013、每股净资产=年末股东权益/年末普通股总数= 2014、每股净资产=年末股东权益/年末普通股总数= 7、资本收益率

2011、资本收益率=净利润/所有者权益×100%=% 2012、资本收益率=净利润/所有者权益×100%=% 2013、资本收益率=净利润/所有者权益×100%=% 2014、资本收益率=净利润/所有者权益×100%=%

电力系统暂态分析要点总结

第一章 1.短路的概念和类型 概念:指一切不正常的相与相与地(对于中性点接地的系统)之间发生通路或同一绕组之间的匝间非 正常连通的情况。类型:三相短路、两相短路、两相接地短路、单相接地短路。 2.电力系统发生短路故障会对系统本身造成什么危害? 1)短路故障是短路点附近的支路中出现比正常值大许多倍的电流,由于短路电流的电动力效应,导体间将产生巨大的机械应力,可能破坏导体和它们的支架。 2)比设备额定电流大许多倍的短路电流通过设备,会使设备发热增加,可能烧毁设备。 3)短路电流在短路点可能产生电弧,引发火灾。 4)短路时系统电压大幅度下降,对用户造成很大影响。严重时会导致系统电压崩溃,造成电网大面积停电。 5)短路故障可能造成并列运行的发电机失去同步,破坏系统稳定,造成大面积停电。这是短路故障的最严重后果。 6)发生不对称短路时,不平衡电流可能产生较大的磁通在邻近的电路内感应出很大的电动势,干扰附近的通信线路和信号系统,危及设备和人身安全。 7)不对称短路产生的负序电流和电压会对发电机造成损坏,破坏发电机的安全,缩短发电机的使用寿命。3.同步发电机三相短路时为什么进行派克变换? 目的是将同步发电机的变系数微分方程式转化为常系数微分方程式,从而为研究同步发电机的运行问 题提供了一种简捷、准确的方法。 4.同步发电机磁链方程的电感系数矩阵中为什么会有变数、常数或零? 变数:因为定子绕组的自感系数、互感系数以及定子绕组和转子绕组间的互感系数与定子绕组和转子绕 组的相对位置θ角有关,变化周期前两者为π,后者为2π。根本原因是在静止的定子空间有旋转的转子。 常数:转子绕组随转子旋转,对于其电流产生的磁通,其此路的磁阻总不便,因此转子各绕组自感系数 为常数,同理转子各绕组间的互感系数也为常数,两个直轴绕组互感系数也为常数。 零:因为无论转子的位置如何,转子的直轴绕组和交轴绕组永远互相垂直,因此它们之间的互感系数 为零。 5.同步发电机三相短路后,短路电流包含哪些分量?各按什么时间常数衰减? 1)定子短路电流包含二倍频分量、直流分量和交流分量;励磁绕组的包含交流分量和直流分量;D轴 阻尼绕组的包含交流分量和直流分量;Q轴阻尼包含交流分量。 2)定子绕组基频交流分量、励磁绕组直流分量和阻尼绕组直流分量在次暂态时按Td’’和Tq’’衰减,在暂 态情况下按Td’衰减;定子绕组的直流分量、二倍频分量和励磁绕组交流分量按Ta衰减。 6.用物理过程分析同步发电机三相短路后各绕组短路电流包含哪些分量? 短路前,定子电流为iwo,转子电流为ifo;三相短路时,定子由于外接阻抗减小,引起一个强制交流 分量△iw,定子绕组电流增大,相应电枢反应磁链增大。励磁绕组为保持磁链守恒,将增加一个直流分 量△ifɑ,其切割定子使定子产生交流分量△iw’。 定子绕组中iwo,iw,iw’不能守恒,所以必产生一个脉动直流,可将其分解为恒定直流分量和二倍频 交流分量。由于励磁绕组切割定子绕组磁场,因此励磁绕组与定子中脉动直流感应出一个交变电流△ifw。 又因为D轴阻尼与励磁回路平行,所以同样含有交流分量和直流分量。 由于假设定子回路电阻为零,定子基频交流只有直轴方向电枢反应因此Q轴绕组中只有基频交流分量 而没有直流分量。 第四章 1.额定转速同为3000转/分的汽轮发电机和水轮发电机,哪一个启动比较快? 水轮发电机启动较快。 2.水轮机的转动惯量比汽轮机大好几倍,为什么惯性时间常数Tj比汽轮机小? 水轮机极对数多于汽轮机的极对数,由n=60f/p得水轮机的额定转速小于汽轮机的转速,又因为惯性时 间常数为Tj=2.74GD2n2/(1000S B),所以T正比于n2,所以水轮机的Tj比汽轮机小。 3.什么是电力系统稳定性?什么是电力系统静态稳定、暂态稳定?区别? (1)电力系统稳定性:指当电力系统在某一运行状态下突然受到某种干扰后,能否经过一定时间后又

电监会企业安全生产标准化一级评审机构

电监会企业安全生产标准化一级评审机构 北京中水大禹技术咨询有限公司 简介

目录 前言...........................................................................................................2 一、公司简介 (5) 二、资格证明 (11) 三、服务业绩 (22) 四、我公司管理体系文件清单及安全管理制度目录 (30)

前言 北京中水大禹技术咨询有限公司(联系方式见文库用户名)是由中国水利电力质量管理协会于2001年1月4日发起成立的一家咨询服务机构,专业从事水利电力行业的水利、水电、供水政策咨询、认证咨询、企业管理咨询、水利水电工程咨询等服务,具备独立法人资格,具有国家认证认可监督管理委员会颁发的认证咨询资质证书,通过中国方圆标志认证中心的第三方外部审核并获颁质量管理体系认证证书。 公司成立12年以来,为200多家发、供电、设计和电力建设等组织提供了咨询服务。 公司为包括五大发电集团和广东省粤电集团、国投集团、华润电力、黔源电力和鲁能德源等众多发电企业提供了企业标准化建设、安全风险管理体系建立、企业发展规划等咨询服务,其中在广东省粤电集团有限公司沙角C电厂“TIMS一体化管理体系”建设咨询成果得全国管理创新成果一等奖,所咨询的标准化项目首家获得全国火力发电企业标准化良好行为AAAA确认证书;为华能滇东能源有限公司所做咨询成果获全国管理创新成果二等奖;在沙角C电厂、平海发电厂、红海湾发电厂、广州蓄能发电厂、国投小三峡发电公司、张家港沙洲电力有限公司等众多发电企业咨询服务过程中,结合安全风险体系、NOSA五星风险管理体系和安全评价等工作的具体要求,探索和掌握了安全管理与发电企业生产实际如何结合的经验,为我公司开

一级注册消防工程师案例分析真题及答案(2015年)

一级注册消防工程师案例分析真题及答案(2015年) 第一题: 某信息中心大楼内设有自动喷水灭火系统、气体灭火系统、火灾自动报警系统等自动消防设施和灭火器。2015年2月5日,该单位安保部队信息中心的消防设施进行了全面检查测试,部分检查情况如下: (一)建筑灭火器检查情况(详见1表) (二)湿式自动喷水灭火系统功能测试情况 打开湿式报警阀组上的试验阀,水力警铃动作,按规定方法测量水力警铃声强为65dB,火灾报警控制器(联动型)接收到报警阀组压力开关动作信号,自动喷水给水泵启动。 (三)七氟丙烷灭火器系统检查情况 信息中心的通信机房没有七氟丙烷灭火系统,系统设置情况(如表2)所示。检查发现,储瓶向2#灭火剂储瓶的压力表显示压力为设计储存压力的85%,系统存在组件缺失的问题。 检查结束后,该单位安保部委托专业维修单位对气体灭火设备进行了维修。维修单位派人到现场,焊接了缺失组件的底座,并安装了缺失组件:对2#灭火剂储瓶补压至设计压力。 根据以上情况作答: 1、根据建筑灭火器检查情况,简述哪些灭火器需要维修、报废。 2、指出素材(二)的场景中存在的问题及自动喷水给水泵未启动的原因,并简述湿式自动喷水灭火器系统联动功能检查测试的方法。 3、七氟丙烷灭火系统在储瓶间未安装哪种组件?最大防护区时对应的驱动装置为几号驱动气瓶? 4、检修维修单位对储瓶间气体灭火设备维修时存在的问题。

第二题: 某购物中心地下2层、地上4层。建筑高度24m,耐火等级二级,地下二层室内地面与室外出入口地坪高差为11.5m。 地下每层建筑面积15200m2。地下二层设置汽车库和变配电房、消防水泵房等设备用房以及建筑面积5820m2的建材商场(经营五金、洁具、瓷砖、桶装油漆、香蕉水等),底下一层为家具,灯饰商场,设有多部自动扶梯与建材商场连通,自动扶梯上下层相连通的开口部位设置防火卷帘。地下商场部分的每个防火区面积不大于2000m2,采用耐火极限为1.5h的不燃性楼板和防火墙及符合规定的防火卷帘进行分隔,在相邻防火分区的防火墙上均设有向疏散方向开启的甲级防火门。 地上一层至三层为商场,每层建筑面积12000m2,主要经营服装、鞋类、箱包和电器等商品。四层建筑面积5600m2,主要功能为餐厅、游艺厅、儿童游乐厅和电影院。电影院有8个观众厅,每个观众厅建筑面积在186m2~390m2之间;游艺厅有2个厅室,建筑面积分别为216m2、147m 2。游艺厅和电影院候场区均采用不到顶的玻璃隔断、玻璃门与其他部位分隔,安全出口符合规范规定。 每层疏散照明的地面水平照度为1.01x,备用电源连续供电时间0.6h。 购物中心外墙外保温系统的保温材料采用模塑聚苯板,保温材料与基层墙体、装饰层之间有0.17m~0.6m的空腔,在楼板处每隔一层用防火封堵材料对空腔进行防火封堵。 购物中心按规范配置了室内外消火栓系统、自动喷水灭火系统和火灾自动报警系统等消防措施。根据以上材料,问题回答; 1、【题干】指出地下二层、地上四层平面布置方面存在的问题。 2、【题干】指出地下商场防火分区方面存在的问题,并提出消防规范规定的整改措施。 3、【题干】分别列式计算购物中心地下一、二层安全出口的最小总净宽度,地下一层安全出口最小总净宽度应为多少?(以m为单位,计算结果保留1位数)

(水利工程)三峡水利枢纽工程审计结果精编

(水利工程)三峡水利枢纽工程审计结果

2007年第4号(总第22号):“三峡水利枢纽工程审计结果”(07-6-29) 【时间:2007年06月29日】【来源:审计署办公厅】【字号:大中小】 三峡水利枢纽工程审计结果 (2007年6月29日公告) 根据《中华人民共和国审计法》的规定,审计署于2006年对长江三峡水利枢纽工程(以下简称三峡工程)进行了审计,重点审计了建设资金筹集使用、工程建设管理、工程造价及综合效益等情况。现将审计结果公告如下: 壹、三峡工程的基本情况 三峡工程是治理和开发长江的关键性骨干工程,建成后水库正常蓄水位175米,总库容393亿 立方米,具有防洪、发电、航运等巨大的综合效益。工程分为大坝、电站、通航建筑物等几个主要部分。大坝全长2309米,坝顶高程185米。电站设有左、右俩组共26台单机额定容量为70万千瓦的大型水轮发电机组。通航建筑物包括双线五级船闸和垂直升船机,分别可通过万吨级船队和3000吨级客货轮。2003年和2005年,国务院三峡工程建设委员会(以下简称国务院三峡建委)又先后批准建设电源电站和右岸地下电站,三峡工程总装机容量达到2250万千瓦,年发电量约880亿千瓦时,主要供应华中和华东地区。 1992年4月,七届全国人大五次会议审议通过《关于兴建长江三峡工程的决议》。1993年,三峡工程开工,至2009年竣工,总工期为17年。工程建设分为三个阶段:第壹阶段从1993年至1997年,完成了大江截流。第二阶段从1998年至2003年,先后建成主坝、左岸电站和永久船闸,按期实现水库初期蓄水、首批6台机组发电和通航三大目标。第三阶段从2004年至2009 年,以实现工程基本完工和全面运营为标志。2006年,大坝全线达到185米设计高程,水库蓄水至156米水位目标。

电力系统暂态分析期末复习重点

1、无限大功率电源的特点是什么?无限大功率电源供电情况下,发生三相短路时,短路电流中包含有哪些电流分量,这些电流分量的变化规律是什么? 答:无限大功率电源的特点是频率恒定、端电压恒定;短路电流中包含有基频交流分量(周期分量)和非周期分量;周期分量不衰减,而非周期分量从短路开始的起始值逐渐衰减到零。 2、中性点直接接地电力系统,发生概率最高的是那种短路?中性点直接接地电力系统发生概率最高的是单相接地短路;对电力系统并列运行暂态稳定性影响最大是三相短路。 3、输电线路装设重合闸装置为什么可以提高电力系统并列运行的暂态稳纵向故障 纵向故障指电力系统断线故障(非全相运行),它包括一相断线和两相断线两种形式。 2、负序分量 是三相同频不对称正弦量的分量之一其特点是三相辐值相等频率相同、相位依次相差1200、相序为C -B -A -C 。 4、转移阻抗 转移阻抗是在经网络等效变换消去除短路点和电源节点后,所得网形网络中电源节点与短路点之间的连接阻抗。 5、同步发电机并列运行的暂态稳定性 答:同步发电机并列运行的暂态稳定性指受到大干扰作用后,发电机保持同步运行的能力,能则称为暂态稳定,不能则称为暂态不稳定。 6、等面积定则 答:在暂态稳定的前提下,必有加速面积等于减速面积,这一定则称为等面积定则。 8、在隐极式发电机的原始磁链方程中,那些电感系数是常数?哪些是变化的?变化的原因是什么? 答:在隐极式发电机的原始磁链方程中,转子各绕组的自感系数、转子绕组之间的互感系数、定子绕组的自感系数、定子各绕组之间的互感系数均为常数;定子三相绕组与转子各绕组之间的互感系数是变化的,变化的原因是转子旋转时,定子绕组和转子绕组之间存在相对位置的周期性改变。 9、提高电力系统并列运行静态稳定性的根本措施是什么?具体措施有那些? 答:提高电力系统并列运行静态稳定性的根本措施是缩短“电气距离”,具体的措施有: 1)采用分裂导线2)线路串联电力电容器;3)采用先进的励磁调节装置;4)提高输电线路的电压等级; 5)改善系统结构和选择适当的系统运行方式; 10、简单电力系统同步发电机并列运行暂态稳定的条件是什么? 简单电力系统同步发电机并列运行暂态稳定的条件是受扰运动中加速面积小于最大减速面积。 11、转移电抗与计算电抗有何异同? 答:相同点是:转移电抗和计算电抗都是网络经化简消去除电源点和短路点之外的所有节点后,连接短路点与电源点的电抗标幺值。不同的是:转移电抗是以统一的功率基准值BS 为基准的电抗标幺值;计算电抗是以电源的额定容量NS 为基准的电抗标幺值。 12、简述应用对称分量法计算不对称短路故障处短路电流的步骤。 答:(1)绘制三序等值电路,计算三序等值电路参数; ② 对三序等值电路进行化简,得到三序等效网络(或三序电压平衡方程); ③ 列故障处边界条件方程; ④ 根据边界条件方程绘制复合序网,求取故障处基本相的三序电流分量(或利用三序电压方程和边界条件方程求解故障处基本相三序电流分量) ⑤ 利用对称分量法公式,根据故障处基本相三序电流分量求故障处各相电流。 2、短路的危害 答:短路的主要危害主要体现在以下方面: 1)短路电流大幅度增大引起的导体发热和电动力增大的危害; 2)短路时电压大幅度下降引起的危害; 3)不对称短路时出现的负序电流对旋转电机的影响和零序电流对通讯的干扰。 1、短路电流最大有效值出现在(1)。A 、短路发生后约半个周期时; 2、利用对称分量法分析计算电力系统不对称故障时,应选(2)相作为分析计算的基本相。B 、特殊相 3、关于不对称短路时短路电流中的各种电流分量,下述说法中正确的是(3)。C 、短路电流中除非周期分量将逐渐衰减到零外,其它电流分量都将从短路瞬间的起始值衰减到其稳态值。 4、不管电力系统发生什么类型的不对称短路,短路电流中一定存在(2)。 B 、正序分量和负序分量; 5、在简单电力系统中,如某点的三序阻抗021∑∑∑==Z Z Z ,则在该地点发生不同类型短路故障时,按对发电机并列运行暂态稳定 性影响从大到小排序,应为(2)。B 、三相短路、两相短路接地、两相短路、单相接地短路; 6、发电机-变压器单元接线,变压器高压侧母线上短路时,短路电流冲击系数应取(2)。B 、1.8; 7、电力系统在事故后运行方式下,对并列运行静态稳定储备系数(%)P K 的要求是()。C 、(%)P K ≧10。 8、下述各组中,完全能够提高电力系统并列运行暂态稳定性的一组是(2)。 B 、变压器中性点经小电阻接地、线路装设重合闸装置、快速切除线路故障; 9、对于三相三柱式变压器,其正序参数、负序参数和零序参数的关系是(2)。 B 、正序参数与负序参数相同,与零序参数不同; 10、分析计算电力系统并列运行静态稳定性的小干扰法和分析计算电力系统并列运行暂态稳定性的分段计算法,就其实质而言都是为

非公开发行股票法律意见书

四川展华律师事务所 关于重庆三峡水利电力(集团)股份有限公司 非公开发行A股股票发行过程及认购对象合规性的法律意见书 致:重庆三峡水利电力(集团)股份有限公司 根据《中华人民共和国证券法》(以下简称《证券法》)、《中华人民共和国 公司法》(以下简称《公司法》)、《中华人民共和国合同法》、《上市公司证券发行管理办法》(以下简称《管理办法》)、《证券发行与承销管理办法》(以下简称《承销办法》)、《上市公司非公开发行股票实施细则》(以下简称《实施细则》)等法律、行政法规、部门规章及其他规范性文件(以下简称“相关法律法规”)的规定,四川展华律师事务所(以下简称“本所”)接受重庆三峡水利 电力(集团)股份有限公司(以下简称“公司”、“发行人”或“三峡水利”) 的委托,作为发行人本次非公开发行A股股票(以下简称“本次非公开发行”) 事宜的特聘专项法律顾问,就本次非公开发行过程及认购对象的合规性出具本法 律意见书。 为出具本法律意见书,本所及经办律师按照中国律师行业公认的业务标准、 道德规范和勤勉尽责的精神,通过出席发行现场、审验相关文件资料、询问相关 人员等方式对本次非公开发行对象的选择、发行价格的确认及配售缴款、验资过 程进行了必要的核查见证。 对于本法律意见书至关重要而又无法得到独立证据支持的事实,本所依赖有 关政府部门、公司或其他有关单位出具的证明文件发表法律意见。 本所同意发行人将本法律意见书作为发行人报告本次非公开发行过程所必 备的法律文件,随同其他资料一同上报中国证券监督管理委员会(下称“中国证监会”)。本所依法对所出具的法律意见承担相应的法律责任。 本法律意见书仅供发行人于本次非公开发行后,按照《承销办法》第五十条 规定向中国证监会报送相关文件之目的使用,未经本所律师事先书面同意,不得三峡水利(600116)非公开发行实施法律意见书四川展华律师事务所 第 2 页共 8 页 被任何人用作任何其他目的。 本所及经办律师依据本法律意见书出具日以前已经发生或存在的事实和现 行有效的相关法律发表法律意见。 本法律意见书的出具基于以下前提: 1、公司向本所及经办律师提供的文件和材料(包括副本和复印件)是完整、 真实、准确和有效的,不存在隐瞒、虚假和重大遗漏。 2、公司向本所及经办律师提供的文件若为复印件或副本的,复印件或副本 都与原件或正本一致。 本所及经办律师按照律师行业公认的业务标准、道德规范和勤勉尽责精神, 对有关文件和事实进行了核查和验证,现出具法律意见书如下: 一、本次非公开发行所取得的批准和授权 1、2009年5月26日,发行人召开第五届董事会第二十一次会议,审议并通过了本次非公开发行的相关议案,并同意将该等议案提交2009年第一次临时股东大

2017年一级注册消防工程师《消防案例分析》真题和答案解析

2016一级消防工程师《消防安全案例分析》真题解析下载 案例一 某寒冷地区公共建筑,地下三层,地上37层,建筑高度169m,总建筑面积121000㎡,按照国家标准设置相应的消防设施。 该建筑室内消火栓系统采用消防水泵串联分区供水形式,分高、低区两个分区。消防水泵和消防水池位于地下一层,设置低区消火栓泵2台(1用1备)和高区消火栓传输泵2台(1用1备),中间消防水泵房和传输水箱位于地上十七层,设置高区消火栓加压泵2台(1用1备),高区消火栓加压泵控制柜与消防水泵布置在同一房间。房顶设置高位消防水箱和稳压泵等稳定装置。低压消火栓由中间传输水箱和低区消火栓泵供水,高区消火栓由屋顶消防水箱和高区消火栓传输泵,高区消火栓加压泵联锁启动供水。 室外消防用水由市政给水管网供水,室内消火栓和自动喷水灭火系统用水由消防水池保证,室内消火栓系统的设计流量为40L/s,自动喷水灭火系统的设计流量为40L/s。 维保单位对该建筑室内消火栓进行检查,情况如下: (1)在地下消防水泵房对消防水池有效容积、水位、供水管等情况进行了检查。 (2)在地下消防水泵房打开地区消火栓泵试验阀,低区消火栓泵没有启动。

(3)屋顶室内消火栓系统稳压装置气压水罐有效储水容积为120L;无法直接识别稳压泵出水管阀门的开闭情况,深入细查发现阀门处于关闭状态,稳压泵控制柜电源未接通,当场排除故障。 (4)检查屋顶消防水箱,发现水箱内的XXXXX管径为DN25,出水管管径为DN75;询问消防控制室消防水箱水位情况,控制室值班人员回答无法查看。 (5)在屋顶打开试验消火栓,防水3min后测量栓口动压,测量值为0.21MPa;消防水枪充实水柱测量值为12m;询问消防控制室有关消防水泵和稳压泵的启动情况,控制室值班人员回答不清楚。 根据以上材料,回答下列问题(共18分,每题2分。每题的备选项中,有2个或2个以上符合题意,至少有一个错项。错选,本题不得分;少选,所选的每个选项得0.5分) 1.关于该建筑消防水池,下列说法正确的有()。 A.不考虑补水时,消防水池的有效容积XXXXX B.消防控制室应能显示消防水池的正常水位 C.消防水池玻璃水位计两端的角阀应常开

水利工程三峡水利枢纽工程外文翻译文献

水利工程三峡水利枢纽工程外文翻译文献(文档含中英文对照即英文原文和中文翻译) The Three Gorges Projects First. The dam site and basic pivot disposal The Three Gorges Projects is select to be fixed on San Dou Ping in Yichang, located in about 40 kilometers of the upper reaches of key water control project of Ge Zhou Ba which was built. River valley, district of dam site, is widen, slope, the two sidesof the bank is relatively gentlely. In the central plains have one island (island, fort of China,), possess the good phased construction water conservancy diversion condition. The foundation of pivot building is the hard and intact body of granite. Have built Yichang and gone to stride bridge that place of 4 kilometers in the about 28 -km-long special-purpose expressway of building site and dam low reaches --West Yangtze Bridge of imperial tomb. Have also built the quay of district of a batch of dams. The dam district possesses the good traffic condition. Two. Important water conservancy project buildings 1. dam The dam is a concrete gravity dam, which is 2309 meters long, it’s height is 185

电力系统暂态分析课后答案(整理版)最新

第一章 1-2-1 对例1-2,取kV 1102 =B U ,MVA S B 30=,用准确和近似计算法计算参数标幺 值。 解:①准确计算法: 选取第二段为基本段,取kV 1102=B U ,MVA S B 30=,则其余两段的电压基准值分别为: 9.5kV kV 110121 5 .10211=?= =B B U k U kV 6.66 .6110 110 223=== k U U B B 电流基准值: kA U S I B B B 8.15 .9330 311=?== kA U S I B B B 16.0110 330 322=?== 3 2.62B I kA = == 各元件的电抗标幺值分别为: 发电机: 32.05.930305.1026.0221=??=*x 变压器1T : 121.05.3130 110121105.02222=??=*x 输电线路: 079.011030 804.02 3=? ?=*x 变压器2T : 21.011030 15110105.02224=??=*x 电抗器: 4.03 .062.26.6605.05=?? =*x 电缆线路: 14.06.630 5.208.026=??=*x

电源电动势标幺值: 16.15 .911 == *E ②近似算法: 取MVA S B 30=,各段电压电流基准值分别为: kV U B 5.101=,kA I B 65.15.10330 1=?= kV U B 1152= ,20.15B I kA = = kV U B 3.63= ,3 2.75B I kA = = 各元件电抗标幺值: 发电机: 26.05.1030 305.1026.0221=??=*x 变压器1T : 230 0.1050.131.5x *=? = 输电线路: 073.011530 804.023=??=*x 变压器2T : 430 0.1050.2115 x *=?= 电抗器: 44.03 .075 .23.6605.05=??=*x 电缆线路: 151.03.630 5.208.026=??=*x 电源电动势标幺值: 05.15.1011 ==*E 习题2 解:(1)准确计算: 3(110)115B B U U kV == 322220 115209.1121 B B U U kV k = =?= 312122010.51159.1121242 B B U U kV k k = =??= 各段的电流基准值为:

企业人才队伍建设调研报告 0

企业人才队伍建设调研报告 **区企业人才队伍建设的现状及对策研究 内容提要:近年来,党中央国务院及重庆市委市政府高度关注三峡移民库区经济社会的发展,尤其注意到以万州为库区中心的产业空心化的问题,为加快以万州为中心的三峡移民库区的产业发展,必须坚持“工业兴万、富民强区”的发展战略,为此,必须加快建设一支数量充足、结构合理、素质较高,能够适应现代企业发展的人才队伍。**区抓住三峡移民契机,大力调整产业结构,全面夯实产业基础,工业企业经过多年的培育和发展,已经形成具有一定规模,门类比较齐全,结构相对合理,实力不断增强,为全区经济社会的发展作出了较大贡献。与此同时,许多企业在人才资源开发、培育、使用等方面做了大量的工作,取得了比较明显的成效,积累了一些好的经验。同时,也应清醒的看到,我区工业企业与重庆主城区相比总体水平还不够高,与近邻涪陵区相比仍有较大差距,与万州新型工业化进程的要求还不相适应。要实现工业兴万、富民强区的目标,必须抓住人才这个关键,明确人才工作目标,以构建七个人才工作平台为主要举措,努力建成以优秀经营管理者、技术(学术)领军人、优秀营销人才和技术能人等四支队伍为核心的企业人才大军。 正确认识我区企业人才队伍建设的现状,了解建设企业人才高地所面临的机遇和挑战,对于建设一支适应经济发展、素

质较高的人才队伍,实现工业兴万、富民强区目标,具有重大战略意义。为此,通过对我区企业比较广泛的调研,并对毗邻地区的学习借鉴,现将有关情况综述如下: 一、**区企业人才队伍建设现状 近年来,区委区政府高度重视我区企业人才队伍建设,在企业人才队伍的培养、选任、激励上采取了一系列有力措施,经过多年的培育和发展,我区已逐步建成一支由企业经营管理者、专业技术人员、营销队伍和高级技工四类人才组成的企业人才队伍,并已具有一定规模,门类比较齐全,企业人才队伍的年龄、文化、专业结构得到了一定程度的优化,后备队伍建设取得了明显成效,整体素质有一定提高,实力有所增强,为全区经济的发展提供了有力的人才支撑。 (一)我区企业人才队伍的基本情况 1.总体数量。到2008年底,我区规模以上企业现有职工约42700 人,其中具有中专以上学历的人才总量约4180人,占职工总数的9.78%。在各类人才中,经营管理人才736人,占职工总数的 1.72%;专业技术人才1156人,占职工总数的2.7%;营销人才495人,占职工总数1.16%;技能人才1793人,占职工总数的4.19%。 2.年龄结构。全区企业4180名各类人才中,30岁及以下438 人,占10.5%,31至40岁1589人,占37.9%,41至50

2018注册一级消防工程师考试真题及答案

2018注册一级消防工程师考试真题及答案 一、阅读分析(案例分析题(共6小题))21分 某居住小区由4座建筑高度为69.0m的23层单元式住宅楼和4座建筑高度为54.0m的18层单元式住宅楼构成。设备机房设地下一层(标高-5.0m),小区南北侧市政道路上各有一条DN300的市政给水管。供水压力为0.25MPa。小区所在地区冰冻线深度为0.85m。 住宅楼的室外消火栓设计流量为15L/s,23层住宅楼和18层住宅楼的室内消火栓设计流量分别为20L/s、10L/s,火灾延续时间为2h。小区消防给水与生活用水共用。采用两路进水环状管网供水,在管网上设置了室外消火栓。室内采用湿式临时高压消防给水系统,其消防水池、消防水泵房设置在一座住宅楼的地下一层。高位消防水箱设置在其中一座23层高的住宅楼屋顶。消防水池两路进水。火灾时考虑补水。每条进水管的补水量为50m3/h,消防水泵控制柜与消防水泵设置在同一房间。系统管网泄漏量测试结果为0.75L/s,高位消防水箱出水管上设置流量开关,动作流量设定值为1.75L/s。 消防水泵性能和控制柜性能合格,室内外消火栓系统系统验收合格。

竣工验收一年后,在对系统进行季度检查时,打开试水阀,高位消防水箱出水管上的流量开关动作,消防水泵无法自动启动。消防控制中心值班人员按下手动专用线路按钮后,消防水泵仍不启动。值班人员到消防水泵房操作机械应急开关后,消防水泵启动。经维修消防控制柜后,恢复正常。 在竣工验收三年后的日常运行中,消防水泵经常发生误动作,勘查原因后发现,高位消防水箱的补水量与竣工验收时相比,增加了1倍。 根据以上材料,回答下列问题(共16分,每题2分,每题的备选项中,有2个或2个以上符合题意,至少有一个错项。错选,本题不得分;少选,所选的每个选项得0.5分) 1.两路补水时,下列消防水池符合现行国家标准的有() A.有效容积为4m3的消防水池 B.有效容积为24m3的消防水池 C.有效容积为44m3的消防水池 D.有效容积为55m3的消防水池 E.有效容积为60m3的消防水池 参考答案:D,E您的答案:D,E 答案解析:

长江三峡水利枢纽工程的利与弊

长江三峡水利枢纽工程的利与弊 三峡水电站,又称三峡工程、三峡大坝。位于中国重庆市到湖北省宜昌市之间的长江干流上。大坝位于宜昌市上游不远处的三斗坪,并和下游的葛洲坝水电站构成梯级电站。它是世界上规模最大的水电站,也是中国有史以来建设最大型的工程项目。而由它所引发的移民搬迁、环境等诸多问题,使它从开始筹建的那一刻起,便始终与巨大的争议相伴。 从构思到践行 在长江三峡建造大坝的设想最早可追溯至中华民国的开创者孙中山先生,他在《建国方略》一书中认为长江“自宜昌以上,入峡行”的这一段“当以水闸堰其水,使舟得溯流以行,而又可资其水利”。按此设想,1940年代中期,国民政府与美国垦务局签约,准备利用美国资金建设水电站。萨凡奇在三度实地考察三峡地区后,写出了《扬子江三峡计划初步报告》,认为三峡工程可行,但后因中国内战,此事无果而终。 文化大革命结束后,中国提出建设“四个现代化”的口号,要兴建一批骨干工程以拉动国民经济的发展,三峡工程于是被再次提上议事日程。1992年4月3日该议案获得通过,标志着三峡工程正式进入建设期。 工程的利 三峡工程主要有三大效益,即防洪、发电和航运,其中防洪被认为是三峡工程最核心的效益。详细可分为以下三点: 一.在三峡工程建成后,其巨大库容所提供的调蓄能力将能使下游荆江地区抵御百年一遇的特大洪水,也有助于洞庭湖的治理和荆江堤防的全面修补。 二. 它是中国西电东送工程中线的巨型电源点,非常靠近华东、华南等电力负荷中心,所发的电力将主要售予华中电网的湖北省、河南省、湖南省、江西省、重庆市,华东电网的上海市、江苏省、浙江省、安徽省,以及南方电网的广东省。 三. 到三峡工程建成后,该段长江将成为湖泊,水势平缓,万吨轮可从上海通达重庆。而且通过水库的放水,还可改善长江中下游地区在枯水季节的航运条件。 我们在看到其有利一面的同时,也必须慎重考虑其不利的一面。我们下一步应该做的,就是要做到未雨绸缪,冷静应对,科学决策,采取积极措施。 工程的弊 工程的弊端问题有很多个:移民、泥沙的淤积、生态环境遭到破坏、名胜和文物的影响等等,这些弊端甚至比工程的利益还要多。我就在下面详述这些弊端。 一.移民是三峡工程最大的难点,在工程总投资中,用于移民安置的经费便占到了45%。当三峡蓄水完成后,将会淹没129座城镇,其中包括万州、涪陵等两座中等城市和十多座小城市,会产生113万移民,在世界工程史

电力系统暂态分析(第四版)考试重点总结

第一章 电力系统故障分析的基础知识 1.(短路)故障 电力系统中相与相之间或相与地之间的非正常连接 类型 横向故障:短路故障;纵向故障:断线故障 危害 (1)短路时,由于回路阻抗减小及突然短路时的暂态过程,使短路电流急剧增加(短路 点距发电机电气距离愈近,短路电流越大) (2)短路初期,电流瞬时值最大,将引起导体及绝缘的严重发热甚至损坏;同时电气设备 的导体间将受到很大的电动力,可能引起导体或线圈变形以致损坏 (3)引起电网电压降低,靠近短路点处电压下降最多,影响用户用电设备的正常工作 (4)改变电网结构,引起系统中功率分布的变化,从而导致发电机输入输出功率的不平 衡,可能引起并列运行的发电机失去同步,破坏系统稳定,造成系统解列,引起大 面积停电(短路造成的最严重后果) (5)短路不平衡电流产生不平衡磁通,造成对通信系统的干扰 2.标幺值的计算 P6 3.无穷大功率电源 电源的电压和频率保持恒定,内阻抗为零 三相短路电流分量(1)稳态对称交流分量(2)衰减直流分量(衰减时间常数T a =L/R ,空载条件下短 路角满足/α - ? /=90 ? 时,直流分量起始值最大) 短路冲击电流 i M = K M I m ,K M :冲击系数 K M =1~2 短路电流最大有效值 ()2M m M 1-K 212 I +=I ; K M =1.8时,??? ??=252.1m I I M ;K M =1.9时,??? ? ?=262.1m I I M 第二章 同步发电机突然三相短路分析 1.三相短路电流分量 定子侧:直流分量,(近似)两倍基频交流分量,基频交流分量(两个衰减时间常数,暂态T d ''、次暂态T d ')转子侧:直流分量,基频交流分量 (暂态过程中,定子绕组中基频交流分量和转子中直流分量衰减时间常数相同,定子侧直流分 量和转子中基频交流分量衰减时间常数相同) 2.分析中引入的物理量及其物理意义 P27-P34 3.基频交流分量初始值的推导 (1)空载P34(2)负载P41 4.Park 变换 交流量→对称直流分量 将静止的abc 三相绕组中的物理量变换为旋转的dq0等值绕组中的物理量 5.空载短路电流表达式 P68 式(2-131) ()()000000'002t cos 1'12cos 1'12t cos 'θθθ+??? ??--??? ??+-+??????+??? ??-=---a a d T t q d q T t q d q d q T t d q d q a e x x E e x x E x E e x E x E i 6.自动调节励磁装置对短路电流的影响 自动调节励磁装置的动作将会使短路电流的基频交流分量增大,但由于励磁电流的增加是 一个逐步的过程,因而短路电流基频交流分量的初始值不会受到影响 第三章 电力系统三相短路电流的实用计算 1.简单系统短路电流交流分量初始值计算P82 2.计算机计算复杂系统短路电流交流分量初始值的原理及计算过程 P95 3.转移阻抗 即消去中间节点后网形网络中电源与短路点间的连接阻抗 第四章 对称分量法及电力系统元件的各序参数和等值电路 1.对称分量法 将三组不对称电流唯一地分解成三组对称的电流来处理 正序(1):幅值相等,相位相差 ,a 超前b 负序(2):幅值相等,相位与正序相反 零序(0):幅值相位相同 ()()()()()()()()()?????++=++=++=021021021c c c c b b b b a a a a F F F F F F F F F F F F ()()()???? ????????????????=??????????0a 2a 1a 22c b a 1a 1a 111F F F a a F F F

一级注册消防工程师考生的六点建议

2018年一级注册消防工程师考生的六点建议 一、想通过考试,一定要有一颗坚定的内心。不能被外界的言论轻易动摇,一旦决定考试,那么就要心无杂念的往前冲;摒弃一切娱乐活动,跟家人也要协调好,有舍才有得。 二、一定要抓住三本教材,三本教材中又以技术实务为核心。消防的知识体系很连贯,把技术实务拿下,也就成功了一半。建议大家从现在开始就着手准备,根据自身情况,一定要有一个自己的学习计划,5月份结束之前,起码保证教材看过三遍以上,不要过早的看规范和图集,没有一定的知识量储备,规范只会起到反作用。当做到合上书本,能流畅的说出章节目录(不是要死记硬背章节目录,这样一点意义没有,而是说书看的多了,闭上眼睛自然而然的知道每本书的内容顺序),就可以进行下一步学习了。 三、在上一条的基础上,开始学习规范。其中又以《建规》、《水规》、《火规》、《自喷规》、《灭火器规范》为重点掌握对象,《建规》和《水规》建议配合相应的图集加深理解。同样规范也需要每隔一段时间拿出来重新阅读记忆。这样会让后面的冲刺很轻松。 四、一定不要过早的做很多试题,复习初期做做章节同步试题,了解一下掌握程度即可。一级注册消防工程师如今已开考两年,出题人的水平,考生们是佩服的无以复加;所以建议大家把这两年的真题仔细研究推敲,并且定期拿出来温习。因为随着学习进度和深度的提升,每次做真题,绝对会有一种新的认识和体会。冲刺期间可以购买我们万题库的冲刺提高班,网校老师将详解命题、剖析真题,同时还将提供考前模拟试卷两套,并做视频解析,对你们通过考试,有一定的帮助作用。加Q2783312322,邀请你消防群学习交流 五、关于最后冲刺期的复习,可以这么安排:对于第二篇建筑防火,实务和能力书不看,全程啃建规,把建规啃明白了,建筑防火自然而然的就拿下,然后对应案例书中建筑防火的案例,进行知识点的整理与巩固;对于第三篇消防设施,可以分模块逐一进行学习,把实务和能力结合起来理解性掌握,尤其是几大消防设施的原理,掌握之后会发现故障什么的根本不用背,按照远离即可一一道来。六、剩下就是一点答题技巧了。首先,平时做案例分析模拟题的时候,一定要动手写,平时就锻炼自己的书写速度,不要单纯的看着答案背一遍,感觉自己背会

2.试述建三峡水利枢纽的利与弊

1、试述建三峡水利枢纽工程的利与弊。 答: 防洪 三峡大坝建成后,将形成巨大的水库,滞蓄洪水,使下游荆江大堤的防洪能力由防御十年一遇的洪水,提高到抵御百年一遇的大洪水,防洪库容在73—220亿立方米之间。如遇1954年那样的洪水,在堤防达标的前提下,三峡能减少分洪100—150亿立方米,荆江至武汉段仍需分洪350—400亿立方米。如遇1998年洪水,可有效防御。 发电 三峡水电站是世界最大的水电站,总装机容量1820万千瓦。这个水电站每年的发电量,相当于4000万吨标准煤完全燃烧所发出的能量。装机(26+6)×70万(1820万+420万)千瓦,年发电846.8(1000)亿度。主要供应华中、华东、华南、重庆等地区。 航运 三峡工程位于长江上游与中游的交界处,地理位置得天独厚,对上可以渠化三斗坪至重庆河段,对下可以增加葛洲坝水利枢纽以下长江中游航道枯水季节流量,能够较为充分地改善重庆至武汉间通航条件,满足长江上中游航运事业远景发展的需要。通航能力可以从每年1000万吨提高到5000万吨。 长江三峡水利枢纽工程在养殖、旅游、保护生态、净化环境、开发性移民、南水北调、供水灌溉等方面均有巨大效益。 除此以外还有水产养殖、供水、灌溉和旅游等综合利用效率。 对库区文物的影响 三峡工程600多公里长的淹没范围,使得如果不采取文物保护,在三峡库区蓄水达175米以后,大量的文物古迹都将被淹没到水下,于是至1996年起,国家按期发放保护资金,三峡工程库区文物的抢救性保护和发掘开始进行。其中重要的文物古迹有涪陵白鹤梁、忠县石宝寨、丁房双阙——无名阙、云阳张飞庙、丰都鬼城、奉节白帝城,此外还有较重要的古栈道5处,石刻、题刻56处,古桥17处;地下文物有较重要的遗址58处,墓群(墓地)45处。其中著名的有奉节县草堂古人类化石点,是三峡水库淹没点唯一一处化石点;云阳县故陵楚墓、北宋的龙脊石题刻,巫山县明清时代的大昌古镇,唐代开始修建的大宁河古栈道等。 将要淹没的地面文物,例如云阳县张飞庙、奉节县的永安宫、巫山县大昌镇的温家大院、秭归县的江渎庙、新滩民居,忠县丁房阙——无名阙,古代桥梁等都按照原工艺、原材料、原形制进行复建(多选址在临近、淹没区以外)。国内外闻名的白鹤梁石刻采取的原址保护方法,即在四十米的水下建设一座博物馆,建成后游人将可到水下参观石刻,摩崖石刻

电力系统暂态分析(第三版)习题答案

第一章 电力系统分析基础知识 1-2-1 对例1-2,取kV 1102=B U ,MVA S B 30=,用准确和近似计算法计算参数标幺值。 解:①准确计算法: 选取第二段为基本段,取kV 1102=B U ,MVA S B 30=,则其余两段的电压基准值分别为:9.5kV kV 110121 5 .10211=?= =B B U k U kV 6.66 .6110110 2 23=== k U U B B 电流基准值: kA U S I B B B 8.15.9330 311=?== kA U S I B B B 16.0110 330 322=?== 各元件的电抗标幺值分别为: 发电机:32.05.930 305.1026.0221=??=*x 变压器1T :121.05.3130 110121105.02 222=?? =*x 输电线路:079.011030 804.02 3=? ?=*x 变压器2T :21.011030 15110105.02 224=?? =*x 电抗器:4.03 .062.26.6605.05=??=*x 电缆线路:14.06.630 5.208.026=??=*x 电源电动势标幺值:16.15 .911 ==*E ②近似算法: 取MVA S B 30=,各段电压电流基准值分别为: kV U B 5.101=,kA I B 65.15.10330 1=?= kV U B 1152=,kA I B 15.0115 330 1=?=

kV U B 3.63=,kA I B 75.23 .6330 1=?= 各元件电抗标幺值: 发电机:26.05.1030 305.1026.0221=??=*x 变压器1T :11.05 .3130 115121105.0222=?? =*x 输电线路:073.0115 30 804.02 3=? ?=*x 变压器2T :21.015 30 115115105.02 24=??=*x 电抗器:44.03 .075.23.6605.05=?? =*x 电缆线路:151.03.630 5.208.02 6=??=*x 电源电动势标幺值:05.15 .1011 ==*E 发电机:32.05.930 305.1026.0221=??=*x 变压器1T :121.05 .3130 110121105.02 222=??=*x 输电线路:079.011030 804.02 3=? ?=*x 变压器2T :21.011030 15110105.02 224=?? =*x 电抗器:4.03 .062.26.6605.05=?? =*x 电缆线路:14.06.630 5.208.026=??=*x 电源电动势标幺值:16.15 .911 ==*E 1-3-1 在例1-4中,若6.3kV 母线的三相电压为: )cos(3.62αω+?= t U s a )120cos(3.62ο-+?=αωt U s a )120cos(3.62ο++?=αωt U s a

相关主题
文本预览
相关文档 最新文档