当前位置:文档之家› 毕业设计 青岛城阳污水处理厂设计

毕业设计 青岛城阳污水处理厂设计

毕业设计 青岛城阳污水处理厂设计
毕业设计 青岛城阳污水处理厂设计

摘要

A2/O法是流程最简单,应用最广泛的脱氮除磷工艺。污水首先进入厌氧池,兼性厌氧菌将污水中的易降解有机物转化成VFAs。回流污泥带入的聚磷菌将体内的聚磷分解,此为释磷,所释放的能量一部分可供好氧的聚磷菌在厌氧环境下维持生存,另一部分供聚磷菌主动吸收VFAs,并在体内储存PHB。进入缺氧区,反硝化细菌就利用混合液回流带入的硝酸盐及进水中的有机物进行反硝化脱氮,接着进入好氧区,聚磷菌除了吸收利用污水中残留的易降解BOD外,主要分解体内储存的PHB产生能量供自身生长繁殖,并主动吸收环境中的溶解磷,此为吸磷,以聚磷的形式在体内储存。污水经厌氧,缺氧区,有机物分别被聚磷菌和反硝化细菌利用后浓度已很低,有利于自养的硝化菌的生长繁殖。最后,混合液进入沉淀池,进行泥水分离,上清液作为处理水排放,沉淀污泥的一部分回流厌氧池,另一部分作为剩余污泥排放。

本工艺在系统上可以称为最简单的同步脱氮除磷工艺,总的水力停留时间少于其他同类工艺。而且在厌氧-缺氧-好养交替运行条件下,不易发生污泥膨胀。

关键词:厌氧池,缺氧池,好氧池,脱氮除磷,A2/O,有机负荷

I

Abstract

A2/O method is the most simple process, one of the most widely applied to take off the nitrogen phosphorus removal process. First YanYangChi into wastewater, sewage of facultative anaerobic bacteria of easily degradable organics into VFAs. Backflow sludge into the phosphorus enrichment bacteria body phosphorus enrichment decompose, this for release phosphorus, the release of energy for the part of aerobic bacteria phosphorus enrichment in anaerobic environment survive, the other part of phosphorus enrichment bacteria for active absorption VFAs, and in store inside body PHB. Oxygen into the area, denitrifying bacteria by using the mixture of nitrate and water into the backflow of organic matter for denitrification denitrification, then into good oxygen area, phosphorus enrichment bacteria in addition to absorbing sewage residual of easily degradable BOD outside, main decomposition of the store inside body produces energy PHB grow for itself, and the dissolution of active absorption conditions of phosphorus, this is p uptake, in the form of phosphorus enrichment in store inside body. The sewage is anaerobic, lack of oxygen area, organic matter were phosphorus enrichment bacteria and denitrifying bacteria using the concentration is low, which is helpful for the denitrifying bacteria growth autotrophic breeding. Finally, the mixture into the sediment basins, spate separation, clear liquid water treatment on as emissions, part of the sludge precipitation backflow YanYangChi, another part as excess sludge emissions.

This process in the system the most simple synchronization can be called off nitrogen phosphorus removal process, and the hydraulic retention time less than other similar technology. And in anaerobic-lack of oxygen-good raised alternate operation conditions, not cause sludge inflation.

Key words:, YanYangChi, hypoxia pool, Aerobic pool, denitrification and phosphorus, A2/O ,organic load

II

目录

摘要 .................................................................................................. I Abstract.............................................................................................. I I 目录 (Ⅲ)

第一章引言 (1)

1.1课题的背景 (1)

1.2 设计依据 (2)

1.3工程概况 (2)

1.3.1 设计水量 (2)

1.3.2 设计水质 (2)

1.3.3 其他资料 (3)

1.4 城市污水的概述 (3)

1.4.1 城市污水的来源 (3)

1.4.2 城市污水的特点 (3)

第二章工艺设计方案的确定 (4)

2.1 污水处理工艺选择原则 (4)

2.2 工艺设计方案对比 (4)

2.2.1 稳定塘工艺 (5)

2.2.2 传统活性污泥法 (5)

2.2.3 AB法 (6)

2.2.4 A2/O法 (6)

2.2.5 氧化沟工艺 (6)

2.2.6 厌氧生物处理工艺 (7)

2.2.7 SBR法 (8)

2.3 污水处理工艺流程的确定 (9)

2.3.1 工艺流程介绍 (9)

2.3.2 可行性分析 (10)

第三章构筑物的设计计算 (11)

3.1 格栅的设计计算 (11)

3.1.1 设计说明 (11)

3.1.2 设计计算 (11)

3.2平流式沉砂池 (11)

3.2.1 设计参数 (12)

3.2.2 设计计算 (12)

3.3 A2/O法 (12)

3.3.1 设计说明 (14)

3.3.2 设计计算 (14)

III

3.4 二沉池 (22)

3.4.1 设计说明 (22)

3.4.2 设计计算 (23)

3.5接触消毒池 (25)

3.5.1 设计参数 (25)

3.5.2二氧化氯消毒剂设计计算 (25)

3.5.3 接触池设计计算 (25)

3.6污泥浓缩池 (26)

3.6.1 设计参数 (26)

3.6.2 设计计算 (27)

第四章污水处理厂总体布置 (28)

4.1 平面布置 (28)

4.1.1 平面布置的一般原则 (28)

4.1.2 管、渠的平面布置 (28)

4.2高程布置 (29)

4.2.1 污水处理高程布置原则 (29)

4.2.2 污水处理厂的高程计算 (29)

第五章主要设备选型 (31)

5.1 XGS型旋转式格栅除污机 (32)

5.2 KZJ型壳背式铸铁矩形闸门 (32)

5.3 HSD-20k型二氧化氯发生器 (32)

5.4 LSF-400型砂水分离器 (33)

5.5 250WFB-BD3泵 (37)

5.6 ML煤气罗茨风机 (33)

5.7 QJB4/12-615/3-480/S潜水搅拌机 (42)

5.8高效微孔橡胶曝气器 (43)

5.9 Lsj1500S7L带式压滤机 (43)

5.10 HDLSY300型螺旋输送机 (44)

第六章工程概预算 (45)

6.1单项构筑物费用 (46)

6.2运行费用 (46)

结论 (49)

参考文献 (50)

致谢 (51)

IV

第一章引言

1.1 课题的背景

随着我国城市化进程的加快,人口集中规模的提高,城市居民生活质量的改善,在城市和区域范围内,单位面积和人均可获得的水资源量与对水的需求量之间的差距呈不断扩大的态势,且局域范围污水排放量的增加,加速了水环境的污染,同时水资源开发与保护的成本在快速上升,城市水环境安全在受着日益严重的威胁。

正是由于我国的水资源短缺,然而经济的发展使得水资源的需求量又很高,工业用水和居民生活用水都给我们国家的水资源造成巨大的威胁。因此水资源的合理利用显得尤其的重要,我们国家水力资源部也对水资源的合理有效持续利用提出了更高的要求。随着人口不断增长和经济飞速发展,用水量及排水量正在逐年增加,污水处理回用投资少,工期短,见效快,比较现实易行,具有重要意义。

1、污水的处理利用,有利于缓解水资源的供需矛盾

人类的生存和发展离不开水资源,而全球性的水资源危机时常发生,严重威胁着人们正常的生活。为了应对此问题,许多国家和地区已开始对城市污水处理回收利用做出了总体规划,通过对污水的处理,产生出一种新的水资源,以缓解紧张的水资源状况。然而,污水的处理究竟又能产生出多少水量呢?据粗略估算,目前城市的供水量有80%变成了污水,而这80%的污水量通过处理后仍有70%可以安全回用,这也就说明了城市供水量的七成,可以变成再生水以重新使用,这就大大减轻了用水资源的紧张状况。

2、污水的回收利用,体现了水资源的“优质优用,低质低用”原则在日程生活用水中,并非都需要优质水。例如,人体直接饮用的水仅占不到5%,而对水质要求不高的生活用水达到了20%以上,甚至高达30%。在美国的佛罗里达州曾规定:市政、娱乐、景观和环境等用水必须采用水质较低的水源。这条规定就体现了出了合理利用水资源的原则。同时也再次证明了对于污水的回用,是

1

可以扩大水资源的利用范围和有效利用程度的。

1.2设计依据

青岛是山东重要城市,由于人口较多且用水量各有不同,因此导致进水水量波动较大。且污水排入墨水河的排污区后,经短距离河道输送汇入胶州湾,排放地点位于墨水河口处,对于墨水河甚至整个青岛的水质影响都非常大。因此现青岛市城阳区拟建一座污水处理站,将全部处理出水达到《城镇污水处理厂污染物排放标准》(GB18918-2002)的二级标准。

1.3工程概况

1.3.1设计水量

污水的平均处理量为Q=50000m3/d =2083.3m3/h,污水的最大处理量为Q=60000m3/d=2500m3/h。日变化系数取K Z为1.2。

1.3.2设计水质

设计水质如表1.1所示:

表1.1 设计水质情况

出水按《城镇污水处理厂污染物排放标准》(GB18918-2002)的二级标准。

1.3.3其他资料

2

1、青岛市与日本东京处于相同纬度,气候相似,属于北温带季风区域,具有海洋性气候特征——空气湿润,温度适中,四季分明,日温差小,气温升降平缓。

2、青岛年平均气温12.7℃。最高气温高于30℃的天数,年平均为11.4天;最低气温低于-5℃的天数,年平均为22天。

3、青岛市年平均无霜期251天,比相邻地区长一个月。

降水量年平均为662.1毫米,年平均降雪日数只有10天。

4、青岛市年平均气压为1008.6毫帕。年平均风速为5.2米/秒,以东南风为主导风向。年平均相对湿度为73%,7月份最高,为89%;12月份最低,为68%。

5、春季持续时间较长,气温回升缓慢;夏季较内陆推迟1个月到来,湿润多雨,但无酷暑,7月平均温度23度;秋季天高气爽,降水少,持续时间长;冬季较内陆推迟15-20天到来,气温低,但并无严寒,一月平均日最低气温-3℃。青岛属正规半日潮港,潮差为1.9~3.5米,大潮差发生于朔或望(上弦或下弦)日后2~3天。

1.4 城市污水的概述

1.4.1城市污水的来源

人们生活中产生的冷却排水、淋浴排水、盥洗排水、厨房排水、厕所排水等。

1.4.2城市污水的特点

1、卫生上安全可靠,无有害物质,其主要衡量指标有大肠菌群数、细菌总数、悬浮物量、生化需氧量、化学耗氧量等;

2、外观上无不快的感觉,其主要衡量指标有浊度、色度、臭气、表面活性剂和油脂等;

3、不引起设备、管道等严重腐蚀、结构和不造成维护管理的困难,其主要衡量指标有PH值、硬度、溶解性固体等。

3

第二章工艺设计方案的确定

2.1 污水处理工艺选择原则

污水处理厂的工艺选择应根据原水水质、出水要求、污水厂的规模、污泥处理方法及当地温度、工程地质、征地费用、电价等因素做慎重考虑,污水处理的每项工艺都有其优点、特点,适用条件和不足之处,不可能用一种工艺代替另一种工艺,同样的工艺在不同的进水和出水条件下,去不同的设计参数,设备的选型并不是一成不变的。根据不同废水的特点,依据下列原则进行处理工艺方案的比较:

1、执行国家关于环境保护的政策,符合国家地方的有关法规、规范和标准;

2、采用先进可靠的处理工艺,确保经过处理后的污水能达到排放标准;

3、采用成熟、高效、优质的设备,并设计较好的自控水平,以方便运行管理;

4、全面规划、合理布局、整体协调,使污水处理工程与周围环境协调一致;

5、妥善处理污水净化过程中产生的污泥固体物,以免造成二次污染;

6、综合考虑环境、经济和社会效益,在保证出水达标的前提下,尽量减少工程投资和运行费用。

2.2工艺设计方案对比

本项目污水处理的特点为:①污水以有机污染为主,BOD/COD =0.45,可生化性较好,重金属及其他难以生物降解的有毒有害污染物一般不超标;②污水中主要污染物指标BOD、COD、SS值为典型城市污水值。

针对以上特点,以及出水要求,现有城市污水处理技术的特点,以采用生化处理最为经济。。根据国内外已运行的中、小型污水处理厂的调查,要达到确定的治理目标,可采用“A2/O活性污泥法”。

好氧技术既可用于高浓度有机废水,也可用于中、低浓度有机废水。而传统活性污泥法、接触氧化法、氧化沟等则一般用于处理中、低浓度有机废水,对于这些废水,使用这些技术一般均能达到废水排放标准。一般情况下,城市

4

污水厂的工艺流程包括预处理段、一级处理段、二级生物处理段和污泥处理段,如果对出水要求较高,还应有三级处理段,即深度处理段。根据设计的排水水/COD>0.3,该城市污水可进行生化处理。二级处理是污水处理质标准,且BOD

5

的中心环节,污水中大部分污染物在二级处理中得到降解和去除,从而使出厂污水达到排放标准。二级处理包括各种物理化学法和各种生物处理法。但各种物理化学法,使用大量昂贵的化学药剂和复杂的工艺过程以及较高的控制技术,不适于易生物处理的污水。现流行的生物二级处理法主要包括:氧化塘、曝气生物滤池、土地处理法、传统活性污泥法以及在传统活性污泥法工艺基础上发展起来的其它方法,如AB法、A/O法、SBR法、氧化沟法、厌氧生物处理工艺等。

2.2.1 稳定塘工艺

稳定塘为一系列露天池塘,根据原水温度,水质及当地气温确定其容积。稳定塘工艺可分为好氧塘、兼性塘,厌氧塘、曝气塘和生物塘(包括养鱼塘和人工植物糖等)。一般厌氧塘、兼氧塘和好氧塘串联使用。从建造和运行角度而言是最经济的一种处理工艺,稳定塘的处理效果一般是令人满意的,只是有些气味。

污水灌溉也称污水的土地处理法,这种污水处理也要求有大面积土地,同时很难解决具有适宜土壤条件的土地,特别是冬季处理技术尚有待进一步研究,目前在未取得适当规模生产性试验资料的情况下,不宜采用。

2.2.2 传统活性污泥法

该法是在人工充氧条件下,对污水和各种微生物群体进行连续混合培养,形成活性污泥。利用活性污泥的生物凝聚、吸附和氧化作用,以分解去除污水中的有机污染物。然后使污泥与水分离,大部分污泥再回流到曝气池,多余部分则排出活性污泥系统

2.2.3 AB法(Adsorption—Biooxidation)

该法由德国Bohuke教授开发。该工艺对曝气池按高、低负荷分二级供氧,

5

A级负荷高,曝气时间短,产生污泥量大,污泥负荷在2.5kgBOD/(kgMLSS·d) 以上,池容积负荷在6kgBOD/(m3·d)以上;B级负荷低,污泥龄较长。A级与B 级间设中间沉淀池。二级池子F/M(污染物量与微生物量之比)不同,形成不同的微生物群体。AB法尽管有节能的优点,但不适合低浓度水质,A级和B级亦可分期建设。

2.2.4 A2/O法(Anaerobic-Anoxic-oxic)

由于对城市污水处理的出水有去除氮和磷的要求,故国内10年前开发此厌氧—缺氧—好氧组成的工艺。利用生物处理法脱氮除磷,可获得优质出水,是一种深度二级处理工艺。A2/O法的可同步除磷脱氮机制由两部分组成:一是除磷,污水中的磷在厌氧状态下(DO<0.3mg/L),释放出聚磷菌,在好氧状况下又将其更多吸收,以剩余污泥的形式排出系统。二是脱氮,缺氧段要控制DO<0.7 mg/L,由于兼氧脱氮菌的作用,利用水中BOD作为氢供给体(有机碳源),将来自好氧池混合液中的硝酸盐及亚硝酸盐还原成氮气逸入大气,达到脱氮的目的。为有效脱氮除磷,对一般的城市污水,COD/TKN为 3.5~7.0(完全脱氮COD/TKN>12.5),BOD/TKN为1.5~3.5,COD/TP为30~60,BOD/TP为16~40(一般应>20)。若降低污泥浓度、压缩污泥龄、控制硝化,以去除磷、BOD5和COD 为主,则可用A2/O工艺

2.2.5氧化沟工艺

本工艺50年代初期发展形成,因其构造简单,易于管理,很快得到推广,且不断创新,有发展前景和竞争力,当前可谓热门工艺。氧化沟具有脱氮的效果且在应用中发展为多种形式,比较有代表性的有:

帕式(Passveer)简称单沟式,表面曝气采用转刷曝气,水深一般在 2.5~3.5m,转刷动力效率1.6~1.8kgO2/(kW·h)。

奥式(Orbal)简称同心圆式,应用上多为椭圆形的三环道组成,三个环道用不同的DO(如外环为0,中环为1,内环为2),有利于脱氮除磷。采用转碟曝气,水深一般在 4.0~4.5m,动力效率与转刷接近,现已在山东潍坊、北京黄村和合

6

肥的污水处理厂应用。

若能将氧化沟进水设计成多种方式,能有效地抵抗暴雨流量的冲击,对一些合流制排水系统的城市污水处理尤为适用。

卡式(Carrousel)简称循环折流式,采用倒伞形叶轮曝气,从工艺运行来看,水深一般在3.0m左右,但污泥易于沉积,其原因是供氧与流速有矛盾。

三沟式氧化沟(T型氧化沟),此种型式由简单,处理效果不错,但其采用转刷曝气,水深浅,占地面积大,复杂的三池组成,中间作曝气池,左右两池兼作沉淀池和曝气池。T型氧化沟构造控制仪表增加了运行管理的难度。不设厌氧池,不具备除磷功能。

交替式氧化沟是SBR工艺与传统氧化沟工艺组合的结果,目前应用的主要有3种氧化沟,分别为VR型、DE型、T型。交替式氧化沟具有良好的脱氮效果,若在起前面设一厌氧池,则起也具有良好的除磷效果。

氧化沟一般不设初沉池,负荷低,耐冲击,污泥少。建设费用及电耗视采用的沟型而变,如在转碟和转刷曝气形式中,再引进微孔曝气,加大水深,能有效地提高氧的利用率(提高20%)和动力效率[达2.5~3.0 kgO2/(kW·h)]。2.2.6 厌氧生物处理工艺

厌氧生物处理是利用厌氧生物的代谢过程,在无需提供氧气的情况下把有机物转化为无机物(沼气和水)和少量的细胞物质,从而达到了废水处理和回收能源目的。

厌氧生物处理工艺运用于食品工业废水,主要原因是废水中含易生物降解的高浓度有机物,且无毒性。此外,厌氧处理动力消耗低,产生的沼气可作为能源,生成的剩余污泥量少,厌氧处理系统全部密闭,利于改善环境卫生,可以季节性或间歇性运转,污泥可长期贮存。因此,厌氧生物处理是一项具有经济效益的处理技术。但是,厌氧处理去除有机物的绝对数量和浓度虽然高,但其出水有机物浓度仍然较高,必须经过后续处理才能达到较高的排放标准,它一般作为好氧工艺的前处理,或者作为排放到城市下水道之前的预处理。

2.2.7 SBR法

7

SBR法早在20世纪初已开发,由于人工管理繁琐未予推广。此法集进水、曝气、沉淀、出水在一座池子中完成,常由四个或三个池子构成一组,轮流运转,一池一池地间歇运行,故称序批式活性污泥法。现在又开发出一些连续进水连续出水的改良性SBR工艺,如ICEAS法、CASS法、IDEA法等。这种一体化工艺的特点是工艺简单,由于只有一个反应池,不需二沉池、回流污泥及设备,一般情况下不设调节池,多数情况下可省去初沉池,故节省占地和投资,耐冲击负荷且运行方式灵活,可以从时间上安排曝气、缺氧和厌氧的不同状态,实现除磷脱氮的目的。但因每个池子都需要设曝气和输配水系统,采用滗水器及控制系统,间歇排水水头损失大,池容的利用率不理想,因此,一般来说并不太适用于大规模的城市污水处理厂。

SBR法是间歇式活性污泥法的简称,它是近年来在国内外被引起广泛重视和研究的日趋增多的一种污水生物处理新技术。现在又开发出一些连续进水连续出水的改良性SBR工艺,如ICEAS法、CASS法、IDEA法等。

SBR法适用于水量、水质排放不均匀的工业废水处理,可节省投资,实现高浓度进水、高容积负荷和高去除率,在处理高浓度有机废水方面独具特色,而且对氮、磷、硫的脱除效果好,特别适合浓度高、排放量小的各种工业有机废水,如化工、造纸、印染等,同时也适合应用于对出水水质要求较高、水量水质波动较大的的污水处理。如青州市日处理5万吨城市污水处理厂就采用SBR工艺。SBR 的改进工艺ABJ ICEAS 工艺:

与传统的SBR 工艺相比,改进的ICEAS 最大的特点是:

1、由于增加了预反应区,使主反应池省去了闲置期,对高峰流量的耐冲击力也得到了保证;

2、单一的池体设计,独立完成处理过程,维护、扩建方便;

3、与SBR 相比,池子尺寸减小了20%,占地节省;

4、与传统处理技术相比,减少了沉淀池以及相关泵送系统,大大降低了成本和能耗;

8

5、无进出水控制阀,节约成本,滗水速率为常数,出水稳定;

2.3污水处理工艺流程的确定

2.3.1、工艺流程介绍

本项目污水处理的特点为:①污水以有机污染为主,BOD/COD =0.45,可生化性较好,重金属及其他难以生物降解的有毒有害污染物一般不超标;②污水中主要污染物指标BOD、COD、SS值为典型城市污水值。

针对以上特点,以及出水要求,现有城市污水处理技术的特点,以采用生化处理最为经济。根据国内外已运行的中、小型污水处理厂的调查,要达到确定的治理目标,可采用“A2/O活性污泥法”。

图1 污水处理工艺流程图

2.3.2 可行性分析

青岛是山东重要工业城市,污水中BOD、COD、SS、酸、碱、有机磷、酚、氯化物、硫化物、苯等浓度较高。

9

设计的城阳水质净化厂处理对象为城市污水,进水水量波动较大。处理后的污水执行《城镇污水处理厂污染物排放标准》(GB18918-2002)二级标准。达标污水排入墨水河的排污区后,经短距离河道输送汇入胶州湾,排放地点位于墨水河口处。此工艺污水处理设施,出水水质能达到10/10/1/1(SS / BOD5 /NH3-N/P),并可完成生物脱氮除磷。因此,工程采用A2/O法处理工艺,使用的工艺需要使得COD/TN=10>8 TP/BOD5=0.03<0.06符合工艺的设计要求。

与传统的活性污泥法工艺相比,A2/O法最大的特点是:

A2/O法是流程最简单,应用最广泛的脱氮除磷工艺。污水首先进入厌氧池,兼性厌氧菌将污水中的易降解有机物转化成VFAs。回流污泥带入的聚磷菌将体内的聚磷分解,此为释磷,所释放的能量一部分可供好氧的聚磷菌在厌氧环境下维持生存,另一部分供聚磷菌主动吸收VFAs,并在体内储存PHB。进入缺氧区,反硝化细菌就利用混合液回流带入的硝酸盐及进水中的有机物进行反硝化脱氮,接着进入好氧区,聚磷菌除了吸收利用污水中残留的易降解BOD 外,主要分解体内储存的PHB产生能量供自身生长繁殖,并主动吸收环境中的溶解磷,此为吸磷,以聚磷的形式在体内储存。污水经厌氧,缺氧区,有机物分别被聚磷菌和反硝化细菌利用后浓度已很低,有利于自养的硝化菌的生长繁殖。

本工艺在系统上可以称为最简单的同步脱氮除磷工艺,总的水力停留时间少于其他同类工艺。而且在厌氧-缺氧-好养交替运行条件下,不易发生污泥膨胀。运行中切勿投药,厌氧池和缺氧池只有轻缓搅拌,运行费用低。

终上所述,面对青岛城阳的现实情况和污水处理特点,采用A2/O法工艺,可以达到国家标准而且投资可达到最省。

10

第三章 构筑物的设计计算

11 第三章 构筑物的设计计算

3.1 格栅的设计计算

3.1.1 设计说明

格栅的主要作用是将污水中的大块污物拦截,以免其对后续处理单元的机泵或工艺管线造成损害。栅条的断面主要根据过栅流速确定,一般过栅流速为0.6~1.0m/s ,槽内流速0.5m/s 左右。如果流速过大,不仅过栅水头损失增加,还可能将已截留在栅上的栅渣冲过格栅,如果流速过小,栅槽内将发生沉淀。此外,在选择格栅断面尺寸时,应注意设计过流能力只为格栅生产厂商提供的最大过流能力的80%,以留有余地。日平均流量Q=50000m 3/d ,变化系数K Z =1.2,其瞬时最大流量Q MAX =0.694m 3/s ,按2个格栅设计。

3.1.2 设计计算

取栅条间距b=0.02m ,栅条宽度S=0.01m

1、栅条间隙数(n)

Q max —最大设计流量,m 3/s ;

α—格栅倾角,取60°;

h —栅前水深,取0.8m ;

ν—污水的过栅流速,取1.0m/s 。

max Q n ehv =

20.5()=个,取22个, 2、栅槽有效宽度(B )

(1)0.01(221)0.02220.65(m) B S n bn =-+=?-+?≈

3、进水渠道渐部分长度(L 1)

设进水渠宽B 1=0.4m ,其渐宽部分展开角α1=20°

1110.650.40.342tan 2tan 20B B L m α--==≈???

4、栅槽与出水渠道连接处的渐窄部分长度L 2

12=0.172L L m =

某城镇污水处理厂工艺初步设计设计说明书(含计算书)

某城镇污水处理厂工艺初步设计设计说明书(含计算书)

目录 1 设计概论 (1) 1.1 课题意义 0 1.2 城镇污水常用处理方法 0 1.3 设计任务 (2) 1.4 设计资料 (3) 1.4.1 厂区概况 (3) 1.4.2 设计规模 (3) 1.4.3 设计水质 (3) 2 污水处理工艺选择 (4) 2.1 常用的城镇污水处理工艺比选 (4) 2.2 工艺方案确定 (7) 2.2.1 A2/O工艺原理 (8) 2.2.2 A2/O工艺流程图 (8) 3 污水处理构筑物设计计算 (9) 3.1 设计水量 (9) 3.2 粗格栅 (9) 3.2.1设计说明 (9) 3.2.2设计要求 (9) 3.2.3设计计算 (10) 3.3 污水提升泵房 (12) 3.3.1 设计说明 (13) 3.3.2 设计要求 (13)

3.3.3 设计计算 (14) 3.4 细格栅 (15) 3.4.1 设计说明 (15) 3.4.2 设计参数 (15) 3.4.3 设计计算 (15) 3.5 沉砂池 (16) 3.5.1 设计说明 (16) 3.5.2 设计要求 (16) 3.5.3 设计参数 (17) 3.5.4 设计计算 (17) 3.6 A2/O生物反应池 (18) 3.6.1 判断是否可用A2/O法 (19) 3.6.2 设计参数 (19) 3.6.3 设计计算(污泥负荷法) (20) 3.7 二沉池 (26) 3.7.1 设计说明 (26) 3.7.2 设计要点 (27) 3.7.3 设计参数 (27) 3.8 配水配泥井 (30) 3.9 接触消毒池 (31) 3.9.1 设计说明 (31) 3.9.2 设计参数 (31) 3.9.3 设计计算 (31) 4 污泥处理构筑物的设计计算 (33) 4.1 污泥量的计算 (33)

污水处理厂毕业设计

第一章设计概述 1.1 设计任务及设计依据 本次设计内容是设计一座二级污水处理厂,使出水达标排放,并对污泥脱水机房臭气进行处理,以改善污水处理厂的工作环境。主要设计任务包括: (1)开题报告(不少于2000字); (2)设计计算说明书(不少于15000字); (3)英文文献翻译(不少于5000汉字); (4)污水处理厂总平面图和流程图(1张); (5)污泥脱水机房臭气处理工艺图(1张); (6)构筑物施工图或主要设备大样图(4张)。 1.1.2 设计依据 1.气象资料 邯郸市地势自西向东呈阶梯状下降,高差悬殊,地貌类型复杂多样。以京广铁路为界,西部为中、低山丘陵地貌,东部为华北平原。海拔最高1898.7米,最低32.7米,相对高差1866米,总坡降为11.8‰。邯郸市自西向东大致可分为五级阶梯:西北部中山区、西部低山区、中部低山丘陵区、中部盆地区、东部冲积平原。 邯郸市属典型的暖温带半湿润大陆性季风气候,日照充足,雨热同期,干冷同季,随着四季的明显交替,依M 次呈现春季干旱少雨,夏季炎热多雨,秋季温和凉爽,冬季寒冷干燥。年平均气温14℃,最冷月份(一月)平均气温-2.5℃,极端最低气温-20℃,最热月份(七月)平均气温27℃,极端最高气温42.5℃,全年无霜期200天,年日照2557小时。 邯郸市多年平均降雨量为548.9mm,最大年降水量为1575.5 mm,最小年降水量为266.8 mm,常年主导风向为夏季东南风,冬季西北风。 2.地质条件 地基承载力98.2kPa,地下水位1.2m,最大冻土深度74.6m,河水最高水位11.80m(大沽标高),河水最低水位10.70m(大沽标高),设计场地平坦,设计标高16.00m(大沽标高)。 1.2 设计水量与水质 1.2.1设计水量

2万吨城市污水处理厂全套设计排水设计说明书

第一章原始资料分析 1.1 城市概况 该城市地处东南沿海,北回归线横贯市区中部,该市在经济发展的同时,城市基础设施的建设未能与经济协调发展,城市的污水处理率仅仅为30%,大量的污水未经处理直接排入河流,使该城市的生态环境受到严重的破坏。为了建设良好优美的现代化城市,必须把环境问题处理好,筹建该城市的污水处理厂已经迫在眉睫了。 该市人口17万人,规划10年后发展到24万人。该市是一个以轻工业、冶金、家电、外贸为主题的新兴现代化城市。 1.2 自然条件 该市具有中低山、丘陵、盆地和平原等多种地貌类型,地势西北高,东南低;历年最高气温38oC,最低气温4 oC,年平均温度为24 oC,常年主导风向为南风;该市内河流最高洪水位+2.5米,最低水位-0.5米,平均水位为+0.5米,地下水位为离地面2.0米,厂区内设计地面标高为+5.0米 1.3 污水量 1.3.1 生活污水量 该市地处亚热带,夏季气候炎热,由于气候和生活习惯,该市在国内一向排水量较高的,据统计和预测,该市近期水量210L/人﹒d。远期水量260L/人﹒d。 1.3.2 工业污水量 市内工企业的生活污水和生产污水总量2.0万m3/d 1.3.3 污水总量 市政公共设施及未预见污水量以4%计,总污水量为生活污水量、工业污水量及市政公共设施与未预见水量的总和。 1.4 污水水质 进水水量:生活污水BOD5为130mg/L;SS为180mg/L; 工业废水BOD5为190mg/L;SS为200mg/L; 出水水质:BOD5≤20mg/L,SS≤20mg/L。 混合污水温度:夏季28OC,冬季10 OC,平均温度20 OC。 1.5 工程设计规模 污水处理厂的设计规模主要按远期需要考虑,以便预留空地以备城市的发展。 1.6 方案选择 1.6.1 工艺的确定 由于该污水处理只需去除BOD5与SS,不考虑脱氮与除磷方面, 所以选择两个比较好的方案. 方案一. 传统活性污泥法,其流程为: 污水→中格栅→提升泵房→细格栅→沉砂池→初沉池→曝气池→二沉池→接触池→处理水排放 方案二. 厌氧池+氧化沟,其流程为: 污水→中格栅→提升泵房→细格栅→沉砂池→厌氧池→氧化沟→二沉池→接触池→处理水排放 1.6.1.1 工艺流程方案的比较和选择 两个方案都能达到处理水质的要求,BOD5,SS去除都能达到出水水质,工艺都是比较简单的,在技术上都是可行的.

某12万吨日城市污水处理厂的A2O工艺设计

某12万吨/日城市污水处理厂的A2/O工艺设计 摘要 本次毕业设计的题目为某城市污水处理厂工艺的设计-A2/O工艺。主要任务是完成该污水处理厂的平面布置、各个构筑物的初步设计和一些处理构筑物施工图的设计。 初步设计要完成设计说明书一份、污水处理厂平面布置图一张、污水处理厂工艺流程图一张以及主要构筑物设计图三张;在主要构筑物设计图的设计中,主要是完成生物池、二沉池和接触消毒池的设计。 该污水处理厂工程,规模为12万吨/日。进水水质见下表: 污水进水水质单位:mg/L 项目COD cr BOD5NH4+-N SS TN0TP0含量270 135 30 135 30 3 本次设计所选择的A2/O工艺,具有良好的脱氮除磷功能。该污水厂的污水处理流程为:污水从粗格栅到污水提升泵房,再从泵房到细格栅,然后到旋流沉砂池,再进入生物池(即A2/O反应池),再从生物池进入二沉池,污水再经过接触消毒池后排入自然水体;污泥处理流程为:旋流沉砂池产生的垃圾直接外运处置,二沉池产生的剩余污泥则运入贮泥池,二沉池的回流污泥则通道管道、污泥回流泵房再次进入A2/O反应池,经过贮泥、加药处理后的污泥,进入污泥浓缩脱水车间,最后外运处理。污水处理厂处理后的出水水质要达到《城镇污水处理厂污染物排放标准》(GB 18918—2002)中的一级b标准。该标准的具体数据如下表所示: 出水水质标准单位:mg/L 项目COD cr BOD5NH4+-N SS TN0TP0含量60 20 15 20 15 1 关键词:A2/O工艺,脱氮除磷,污水处理,污泥处理

THE A2/O PROCESS DESIGN OF A CITY SEWAGE TREATMENT PLATE ABSTRACT The subject of this graduation project for a municipal sewage treatment plant process design—A2/O process.Main task is to complete the layout of the sewage treatment plant,the preliminary design of the various structures and construction plans of dealing with the design of structures. To complete the preliminary design of a design manual, wastewater treatment plant with a floor plan, flow chart of a sewage treatment plant and the design of three main structures;design of the main design of structures, mainly is the biological pool, secondary sedimentation tank design and contact disinfection tank. This sewage treatment plant project,the scale is 120000m3/d. The influent water quality is in the table below. Influent water quality units:mg/L Project COD cr BOD5NH4+-N SS TN0TP0 Content 270 135 30 135 30 3 The selected A2/O process, has a good Nitrogen and Phosphorus Removal.This sewage treatment plant for the sewage treatment process is: sewage from the coarse grid to enhance the pumping station,then from the pump to the fine grid,And then to the cyclone grit chamber, then entering the biological pool(A2/O reactor),then from the pool into the secondary sedimentation tank,after exposure to water disinfection and then discharged into the natural water ; Sludge treatment process is : vortex grit chamber sludge into the sludge

污水处理厂初步设计方案

中国泉州出口加工区污水处理厂工程 初步设计 第一册初步设计说明书 中国市政工程中南设计研究院 二OO七年十二月(福州)

总院院长:杨远东 总工程师:李树苑 分院院长:赵红兵 项目负责人:陈傲 主要参加编制人员: 工艺:赵红兵周林凡袁尚 张小刚詹键陈傲建筑:胡建华李涛 结构:李必正谢立中何远园电气:王英豪贾瑟 工程经济:徐久红张俊

总目录 第一册初步设计说明书第二册工程概算书 第三册设计图纸

目录 1.总论 (1) 1.1项目概况 (1) 1.2编制依据、原则和范围 (2) 1.3规范和标准 (4) 1.4工程建设产业化政策 (6) 2.工程概述 (8) 2.1 项目开发建设的背景 (8) 2.2 工程服务范围的确定 (9) 2.3 水量预测及工程规模 (9) 2.4 进水水质 (12) 2.5 出水水质 (15) 2.6 污水厂厂址 (15) 2.7 污水厂尾水排放 (17) 3.污水处理工艺 (18) 3.1设计原则 (18)

3.2 污水处理工艺 (19) 3.3 污水处理工艺流程选择 (23) 4.污泥处理工艺 (39) 4.1污泥处理目的 (39) 4.2污泥处理工艺 (40) 4.3污泥最终处置 (42) 5.污水厂工艺流程设计 (48) 5.1 污水厂工艺流程 (48) 5.2 生产构筑物工艺设计 (49) 5.3 辅助建筑物工艺设计 (59) 5.4 污水处理厂平面布置 (60) 5.5 尾水排放 (62) 5.6 厂区道路 (62) 5.7厂区给水排水 (63) 5.8通讯系统 (63) 5.9 厂外配套工程 (64)

设计题目:某城市污水处理厂设计

设计题目:某城市污水处理厂设计第一章设计资料 一、自然条件 1、气候:该城镇气候为亚热带海洋季风性季风气候,常年主导风向为东南风。 2、水文:最高潮水位 6.48m(罗零高程,下同) 高潮常水位 5.28m 低潮常水位 2.72m 二、城市污水排放现状 1、污水水量 (1)生活污水按人均生活污水排放量300L/人.d; (2)生产废水量按近期1.5万m3/d,远期2.4万m3/d; (3)公用建筑废水量排放系数按近期0.15,远期0.20考虑; (4)处理厂处理系数按近期0.80,远期0.90考虑。 2、污水水质 (1)生活污水水质指标为 CODcr 60g/人.d BOD5 30g/人.d (2)工业污染源参照沿海开发区指标,拟定为: CODcr 300mg/L; BOD5 170mg/L (3)氨氮根据经验确定为30md/L。 三、污水处理厂建设规模与处理目标 1、建设规模 该污水处理厂服务面积为10.09km2,近期(2000年)规划人口为6.0万人,远期(2020年)规划人口为10.0万人。处理水量近期3.0万m3/d,远期6.0万m3/d。 2、处理目标 根据该城镇环保规划,污水处理厂出水进入的水体水质按国家3类水体标准控制,同时

执行国家关于污水排放的规范和标准,拟定出水水质指标为 CODcr≤100mg/L;BOD5≤30mg/L;SS≤30mg/L ;NH3-N≤10mg/L 四、建设原则 污水处理工程建设过程中应遵从下列原则:污水处理工艺技术方案,在达到治理要求的前提下应优先选择基建投资和运行费用少、运行管理简便的先进的工艺;所用污水、污泥处理技术和其他技术不仅要求先进,更要求成熟可靠;和污水处理厂配套的厂外工程应同时建设,以使污水处理厂尽快完全发挥效益;污水处理厂出水应尽可能回用,以缓解城市严重缺水问题;污泥及浮渣处理应尽量完善,消除二次污染;尽量减少工程占地。 第二章污水处理工艺方案选择 一、工艺方案分析 本项目污水以有机污染为主,BOD/COD=0.54 可生化性较好,重金属及其他难以生物降解的有毒有害污染物一般不超标,针对这些特点,以及出水要求,现有城市污水处理技术的特点,以采用生化处理最为经济。由于将来可能要求出水回用,处理工艺尚应硝化。 根据国内外已运行的大、中型污水处理厂的调查,要达到确定的治理目标,可采用“普通活性污泥法”或“氧化沟”法。 普通活性污泥法,也称传统活性污泥法,推广年限长,具有成熟的设计运行经验,处理效果可靠,如设计合理,运行得当,出水BOD5可达10-20mg/L,它的缺点是工艺路线长,工艺构筑物及设备多而复杂,运行管理困难,运行费用高。 氧化沟处理技术是20世纪50年代有荷兰人首创。60年代以来,这项技术在国外已被广泛采用,工艺及构筑物有了很大的发展和进步。随着对该技术缺点(占地面积大)的克服和对其优点的逐步深入认识,目前已成为普遍采用的一项污水处理技术。 氧化沟工艺一般可不设初沉池,在不增加构筑物及设备的情况下,氧化沟内不仅可完成碳源的氧化,还可实行脱氮,成为A/O工艺,由于氧化沟内活性污泥已经好氧稳定,可直接浓缩脱水,不必厌氧消化。 氧化沟污水处理技术已被公认为一种成功的革新的活性污泥法工艺,与传统活性污泥系统相比较,它在技术、经济等方面具有一系列独特的优点。 1、工艺流程简单、构筑物少,运行管理方便。一般情况下,氧化沟工艺可比传统活性污泥 法少建初沉池和污泥厌氧消化系统,基建投资少。另外,由于不采用鼓风曝气和空气扩散器,不建厌氧硝化系统,运行管理方便。

塑料检查井

塑料检查井的发展前景 塑料检查井第一次在国内使用便引起的巨大的反应,其发展前景不可小觑。塑料检查井产业的发展不但推动了污水排放、污水处理两个系统领域的产业革命,以先进的排放方式来取代传统落后排放观念,借助产学协作科技创新完善产品结构,一切获取最终回归社会。现如今的塑料检查井具有较强的耐腐蚀、使用寿命长,安装方便,进度快,节约宝贵土地资源,柔性连接不渗漏,流槽内壁光滑不堵塞,均匀沉降不拉裂,防止地下水二次污染等特性,完全符合我国“十二五”规划中“生态环境不断优化,主要污染物排放总量进一步下降”的主要目标,也是中国建筑史上一次革命。 从21世纪以来,城市发展就一直非常快,慢慢的城市中一些建筑建材的问题就显露出来了,城市常年内涝,这些都是有必然的因素所在的。越来越注重地表的建筑,对地下建设关注极少,排水系统逐渐老化和落后,已经跟不上城市的发展了;一些城市在暴雨应急机制、政府管理能力等方面都存在一定的漏洞;城市道路建设多以水泥沥青为主,也导致降水难以渗透到地底下;排水系统设计标准过低,仅仅能抵制1年一次大暴雨天气,而且是1-3年一遇的标准,也就是能够适应每小时36毫米到45毫米的降雨,5年一遇的标准,即每小时56毫米的降雨量。所以在一次性成型塑料检查井出现的这十几年中,从建筑小区排水到市政小区的排水,基本上涉及到的面非常广泛。 中国的检查井发展大致经历了粘土井、水泥砌块、预制混凝土不锈钢、玻璃钢检查井、塑料检查井的过程,目前最为流行的就是塑料检查井,它的排水能力是传统的排水检查井的1到3倍。在塑料检查井之前的检查井,普遍存在很多的问题,比如占地面积大、耗费材料多、安装过程繁杂,安装也不够灵活、对环境造成的污染也很严重,由于其没有防泄漏的功能,所以会对地下水造成二次的污染,一个很重要的问题就是由于传统检查井容易堵塞,从而大大降低了排水效率,给后期的维护疏通也带来很大的困难。而塑料检查井就很好的克服了以上传统检查井的不足,具有排水效率高、节能、节水、节材、施工速度快、工程造价低、绿色环保、节约耕地、安全防渗漏、国家支持政策等优势。塑料检查井内壁光滑流畅,设有导流槽,污物不易滞留,减少了堵塞的可能,有着出色的排水性能,雨污排放率是传统检查井的1~3倍。人们都说低碳环保,但是这不仅仅只是嘴上说说的,需要有实际行动,而且美在细节,那么塑料检查井就是将美体现在了细节上。塑料检查井的主要优势就是能击败砖砌井,节省了砖砌井的时间,也减少经济收入,保证了质量,还加快了施工速度,对于环保方面更不会污染地下水资源,塑料检查井是大势所趋。 在国外的一些发达国家如美国、日本、英国、荷兰、德国等,从上世纪80年代就开始研究应用塑料检查井。美国、欧洲的此类产品体积偏向于大型。发达国家地广人稀,像我们国内如此高人口密度的小区很少,因此国外检查井的特点是管道口径比较小,污水管道的口径基本上都是在Ф110mm~Ф200mm之间。总的来说,国外塑料检查井的应用情况有如下特点:1、先小后大:塑料检查井先是在建筑小区推广,然后在市政排水中应用;2、塑料井的材质多样化:PVC-U,PPB,PE,UP-GF等,但注塑井的材质以PVC-U和PPB为主;3、成型工艺:在塑料检查井推广的早期,成型工艺有注塑、滚塑、模压和两次成型(焊接)等,但随

污水处理厂毕业设计

摘要 随着人类生存环境的不断恶化和自然资源的日益减少。人类社会的可持续发展面临着严峻地挑战,这迫使人类必须重视自然环境的保护与利用,自然资源的合理开发与利用这样一个生死攸关的大问题。而在这个大问题中,水又是最重要的.因为水是生命的源泉,"民以水为天"。水在自然资源中是应用最普遍,分布最广泛,对人类最重要的自然资源。随着人类社会的发展,人类已经认识到,水不是取之不尽用之不竭的,水是有限的。而这有限的水,正遭到严重污染,这使本来就十分匮乏的水资源更加匮乏。一方面严重缺水,另一方面又有大量污水排出,流入江河湖海污染水体。污水处理既可解决水源的严重污染,又可开发新水源,应该说这是一项事半功倍的事业。 城市人口的递增,城市规模的扩大,城市工业生产的发展,生活污水和工业废水排出量日益增多,大量未经处理的污水直接排入周围河流,致使城市周围环境污染十分严重,不但直接污染了市区的地下饮用水,而且对河流下游地区的农业生产和人民生活造成了危害,人类和生物赖以生存的生态环境受到了日益严重的威胁。同时,水生态系统体现了人与水的和谐共存与协调发展,是城市生态系统的主要组成部分和关键因素,与一个城市的可持续发展密切相关。因而,城市污水治理已成当前迫切需要解决的问题之一。我们通过建设城市污水处理厂,经过一级物理法和二级生物法对污水进行处理然后再将它排入水体,以减轻水体的负担。 关键词:A2O工艺,辐流式二沉池,平流沉砂池

ABSTRACT The human living environment is deteriorating and the natural resources become less and less. The sustainable development of human society is facing severe challenges, forcing humans must attach importance to the protection of the natural environment and the use, the reasonable development and utilization of natural resources such a life-and-death problem. In this big problem, water is the most important, because water is the source of life, "the people water for the sky". Water is the most widely used and most widely distributed natural resource in natural resources. With the development of human society, mankind has realized that water is not inexhaustible and water is limited. And this limited water is being severely polluted, which makes the already scarce water resources even more scarce. On the one hand, there is a severe shortage of water, and on the other hand, there is a large amount of sewage flowing into the rivers and lakes to contaminate the water. Sewage treatment can solve the serious pollution of water source, but also can develop new water source, should say that this is a business with half the effort. Increasing urban population, the expansion of city scale, the development of the city's industrial production, domestic sewage and industrial waste water discharge amount is increasing, a large number of untreated sewage directly discharged into the surrounding rivers,

污水处理厂课程设计书

广州大学市政技术学院课程设计书 课程设计名称:某城市污水处理厂设计 系部环境工程系 专业 14环境 班级 14环工 姓名邓敏艳 指导教师王昱 2016 年 5 月 30 日

目录 一、课程设计内容说明 (3) 二、设计原始数据资料 (3) (一)城镇概况 (3) (二)工程设计规模: (4) (三)厂区附近地势资料 (4) (四)气象资料 (5) (五)水文资料 (5) 三、课程设计基本要求 (6) 四、课程设计 (6) (一)、计算设计流量 (6) (二)、计算设计格栅 (6) (二)、沉砂池 (9) (三)、曝气池 (10) 1、曝气池的计算与各个部位尺寸的确定 (10) 2、曝气系统的计算与设计 (12) 3、供气量的计算 (13) 4.空气管系统计算 (14) (四)、二沉池设计 (19) 4.1、二沉池池体计算 (19) 4.2、二次沉淀池污泥区的设计 (20) 4.3、二沉池总高度: (21) 五、污水处理厂平面布置图 (22) 六、污水处理厂的高程布置 (22) 6.1、水力损失的计算 (22) 6.1.1、构筑物水力损失表: (22) 6.1.2、污水管道水力计算表: (22) 6.2、构筑物水面标高计算表: (23) 6.3、污水处理厂的高程布置 (23) 七、参考文献资料 (24) 八、总结 (24)

一、课程设计内容说明 进行某城镇污水处理厂的初步设计,其任务包括: 1、根据所给的原始资料,计算进厂的污水设计流量; 2、根据水体的情况、地形和上述计算结果,确定污水处理方法、流程及有关处理构筑物; 3、对各构筑物进行工艺设计计算,确定其型式、数目与尺寸; 4、进行各处理构筑物的总体布置和污水流程的高程设计; 5、设计说明书的编制。 二、设计原始数据资料 (一)城镇概况 该城市地处东南沿海,北回归线横贯市区中部,该市在经济发展的同时,城市基础设施的建设未能与经济协同发展,城市污水处理率仅为3.4%,大量的污水未经处理直接排入河流,使该城市的生态环境受到严重的破坏。为了把该城市建设成为经济繁荣、环境优美的现代化城市,筹建该市的污水处理厂已迫在眉睫。该城镇计划建设污水处理厂一座,并已获上级计委批准。 目前,城镇面积约28Km2,根据城镇总体规划,城镇面积40Km2,其出水进入B江,B江属地面水Ⅲ类水体,要求排入的污水水质执行《污水综合排放标准》(GB18918-2002)中的一级标准中的B类标准,

污水处理厂毕业设计说明书 完整版可做毕业设计模版

给水排水工程专业 毕业设计任务书 设计题目:朔州市恢河污水处理厂设计 学生:李文鹃 指导教师:杨纪伟 完成日期:2006年2月日---2006年6月日 河北工程大学城建学院 给水排水教研室 2006年2月 一、设计题目:朔州市恢河污水处理厂设计 二、设计(研究)内容和要求:(包括设计或研究内容、主要指标与技术参数,并根 据课题性质对学生提出具体要求) 根据朔州市城市总体规划图和所给的设计资料进行城市污水处理厂7设计。设计内容如下: 1、完成一套完整的设计计算说明书。说明书应包括:污水水量的计算;设计方案对 比论证;污水、污泥、中水处理工艺流程确定;污水、污泥、中水处理单元构筑物的详细设计计算,(包括设计流量计算、参数选择、计算过程等,并配相应的单线计算草图),厂区总平面布置说明;污水厂环境保护方案;污水处理工程建设的技术经济初步分析等。 2、绘制图纸不得少于8张,所有图纸按2#图出。(个别图纸也可画成1#图)。此外, 其组成还应满足下列要求: (1)污水处理工艺及污水回用总平面布置图1张,包括处理构筑物、附属构筑物、配水、集水构筑物、污水污泥管渠、回流管渠、放空管、超越管渠、 空气管路、厂内给水、污水管线、中水管线、道路、绿化、图例、构筑物 一览表、说明等。 (2)污水处理厂污水和污泥及污水回用工程高程布置图1张,即污水、污泥、中水处理高程纵剖面图,包括构筑物标高、水面标高、地面标高、构筑物 名称等。 (3)污水总泵站或中途泵站工艺施工图1张。 (4)污水处理及污泥处理工艺中两个单项构筑物施工平面图和剖面图及部分大样图3~4张。 (5)污水回用工程中主要单体构筑物工艺施工图1~2张。 3、完成相关的外文文献翻译1篇(不少于5000汉字)。外文资料的选择在教师指导 下进行,严禁抄袭有中文译文的外文资料。

污水处理厂初步设计方案及施工图设计

污水处理厂初步设计方案及施工图设计 污水处理厂初步设计方案及施工图设计 污水处理厂初步设计方案及施工图设计 1 污水处理厂初步设计方案及施工图设计 第一章概述 1.1工程概况 ⑴项目名称:某县污水处理厂工程⑵项目主管单位:某县建设委员会 ⑶项目建设单位:某县城市建设经营发展有限公司 ⑷工程规模:4万m3/d(其中一期工程2万m3/d,二期工程2万m3/d)。本次投标的设计内容为一期工程初步设计及施工图设计。 ⑸工程内容:处理能力2万m3/d的污水处理厂,不包括市政污水管网工程。 ⑹污水处理厂厂址:某县城北部杨家沙滩,南侧距离某城区北外环线约1500米,东侧紧邻青通河。 ⑺污水厂一期工程设计水质 a.设计进水水质 CODcr: 300mg/L BOD5: 150mg/L SS:

250mg/L NH3-N: 30mg/L TP: 2.5mg/l b.设计出水水质 CODcr: ≤60mg/L BOD5: ≤20mg/L SS: ≤20mg/L TN: ≤20mg/L NH3-N: ≤8mg/L(温度小于12℃时为15mg/L) TP: ≤1.0mg/L 粪大肠菌群:≤104个/L ⑻工程项目现场熟悉情况 投标文件准备阶段,我公司组织有关人员两次赴某县踏勘现场,并就项目基本情况与走访了县有关部门,在此基础上并结合本公司的设计、运行经验,提出如下设计 2 污水处理厂初步设计方案及施工图设计 思路: a.省级经济开发区某县工业园规划面积8km2,目前近百家企业入驻园区,园区工业废水水量、水质对某县污水处理厂将来的运行影响不可忽视,污水处理工艺必须耐水质、水量的冲击影

2万吨城市污水处理厂全套设计排水设计说明书

2万吨城市污水处理厂全套设计排水设计说明书

第一章原始资料分析 1.1 城市概况 该城市地处东南沿海,北回归线横贯市区中部,该市在经济发展的同时,城市基础设施的建设未能与经济协调发展,城市的污水处理率仅仅为30%,大量的污水未经处理直接排入河流,使该城市的生态环境受到严重的破坏。为了建设良好优美的现代化城市,必须把环境问题处理好,筹建该城市的污水处理厂已经迫在眉睫了。 该市人口17万人,规划10年后发展到24万人。该市是一个以轻工业、冶金、家电、外贸为主题的新兴现代化城市。 1.2 自然条件 该市具有中低山、丘陵、盆地和平原等多种地貌类型,地势西北高,东南低;历年最高气温38oC,最低气温4 oC,年平均温度为24 oC,常年主导风向为南风;该市内河流最高洪水位+2.5米,最低水位-0.5米,平均水位为+0.5米,地下水位为离地面2.0米,厂区内设计地面标高为+5.0米 1.3 污水量 1.3.1 生活污水量 该市地处亚热带,夏季气候炎热,由于气候和生活习惯,该市在国内一向排水量较高的,据统计和预测,该市近期水量210L/人﹒d。远期水量260L/人﹒d。 1.3.2 工业污水量 市内工企业的生活污水和生产污水总量2.0万m3/d 1.3.3 污水总量 市政公共设施及未预见污水量以4%计,总污水量为生活污水量、工业污水量及市政公共设施与未预见水量的总和。 1.4 污水水质 进水水量:生活污水BOD5为130mg/L;SS为180mg/L; 工业废水BOD5为190mg/L;SS为200mg/L; 出水水质:BOD5≤20mg/L,SS≤20mg/L。 混合污水温度:夏季28OC,冬季10 OC,平均温度20 OC。 1.5 工程设计规模 污水处理厂的设计规模主要按远期需要考虑,以便预留空地以备城市的发展。 1.6 方案选择 1.6.1 工艺的确定 由于该污水处理只需去除BOD5与SS,不考虑脱氮与除磷方面, 所以选择两个比较好的方案. 方案一. 传统活性污泥法,其流程为: 污水→中格栅→提升泵房→细格栅→沉砂池→初沉池→曝气池→二沉池→接触池→处理水排放 方案二. 厌氧池+氧化沟,其流程为: 污水→中格栅→提升泵房→细格栅→沉砂池→厌氧池→氧化沟→二沉池→接触池→处理水排放 1.6.1.1 工艺流程方案的比较和选择 传统活性污泥法氧化沟 优点: 1.有机物经历了第一阶段的吸附和第二阶段的代谢的完整过程,活性污泥也历了一个从池道端的对数增长,经减速增长到池末端的内源呼吸的完全生长周期 2.在池首端和前段混合液中的溶解氧浓度较低 3.效果好,BOD除率达90%以上缺点: 1.曝气池首端有机污染物负荷 高,耗氧速度也高 2.暴气池溶积大,基建费用高. 3.供氧与需氧不平衡 4.对进水水质,水量变化的适应 性较低,动行效果易受水质,水 量变化的影响 优点: 1.可考虑不设初沉池,有机 性悬浮物在氧化化沟内能 太到好氧稳定的程度 2.可考虑不单敲边鼓二次 沉淀池,可少去污泥回流装 置. 3.BOD负荷低 缺点: 1.占 地面 积较 大 两个方案都能达到处理水质的要求,BOD5,SS去除都能达到出水水质,工艺都是比较简单的,在技术上都是可行的. 最终选择厌氧池+氧化沟处理工艺是因为:氧化沟是活性污泥系统的新工艺,与传统活性污法比较,期暴气系具有以下各项效益:1.对水温水质,水量的变动有较强的适应性2.污污龄一般可达15-30d,为传统活性污泥系统的3-6倍. 可以存活,繁殖世代时间长,增殖速度慢的微生物,如硝化菌,在氧化沟内可能产生硝化反应.如运行得当能够具有反硝化脱氮的效应.3.污泥产率低,且

青岛麦岛污水处理厂实习报告

中国海洋大学本科实习报告 实习名称参观麦岛污水处理厂 学院(系、中心)环境科学与工程学院 专业年级环境工程 学生姓名吴澜 学号 140112010044 教务处制表 二Ο一零年六月七日

一、实习教学基本概况 实习类型教学实习修课要求必修实习名称参观污水处理厂课程(实习)编号 学时学分 实习起止时间2013年5月24日实习地点青岛市市南区麦岛污水处理厂 实习单位麦岛污水处理厂实习岗位 指导教师学历/职称 实习指导教材实习总结形式调查报告实习成绩其他情况说明 二、实习教学内容 1.实习目的、要求: 认识实习旨在充分调动学生参加实践活动的能动性,使学生把学过的理论知识与工厂实践有机结合起来,巩固和丰富有关环境工程专业知识,培养学生观察分析生产中实际问题的能力,锻炼和培养学生良好的品德和严守纪律的作风。 了解典型城市污水厂的处理工艺、构筑物、设备及其重要的工艺参数,收集必要的工艺参数,初步掌握污水处理设计内容;认真完成实习报告的写作与讨论。 2.实习主要内容: 了解我国污水处理的基本现状以及相关的规定;通过污水处理过程的参观、考察,学会收集分析和掌握原始资料;了解污水处理厂管理技术,学习前人的生产实践经验,并分析存在的问题,为今后解决工程实际问题打下基础。

三、实习总结(可另附纸) (一)麦岛污水处理厂概述 该项目前期投资约6.8亿元。服务范围为西起大学路,东至石老人,南临黄海,北靠崂山山脉,总面积约35km2。该工期为30个月。该项目位于青岛市崂山区大麦岛村及徐家麦岛村,距现状麦岛污水处理厂东约400m处。项目建设规模为26万m3/d,分两期进行,近期到2010年建设规模为18万m3/d,远期到2020年建设规模增加8万m3/d。服务范围西起大学路,东至石老人,南临黄海,北靠崂山山脉,总面积约35km2。 拟建工程污水处理工艺为预处理、一级处理、Biostyr生物滤池二级处理、三级处理;污泥处理工艺为污泥脱水、外运混燃;臭气处理工艺为集中收集化学处理。该工程设计出水水质为《城镇污水处理厂污染物排放标准》(GB18918-2002)一级B标准。考虑到续建工程周边地区环境和景观的敏感性和高标准的要求,本工程采用全地下式的布置方式。 麦岛污水处理厂位于青岛市前海东部地区,东海路南侧,南临黄海,东近海洋娱乐城,西邻渔轮修造厂。一期工程于1999年底建成投产,设计规模为10万m3/d,工程占地1.71 hm2,污水经预处理后通过DN1000、长1030m的管道深海排放。 麦岛污水处理厂二期汇水区域为麦岛污水系统,西起青岛路东至石老人,南临黄海北靠崂山山脉,西与团岛北与海泊河排水系统相邻,东西长约20km,南北宽1~3km,总面积35km2,沿途污水通过多级泵站提升进入处理厂。扩建后污水处理流程高效,构筑物结构紧凑。扩建工程设计规模为14万m3/d,工程总用地4.54公顷,总投资2.44亿元。2005年8月开工建设,在2006年8月奥帆测试赛期间第一阶段运行,2007年6月开始试运行,2007年7月正式运行。扩建项目由威立雅水务及光大投资,建成后由青岛威立雅水务运营有限公司运营。麦岛污水处理厂污水处理构筑物由粗格栅及进水提升泵站、细格栅及除油沉砂池、MULTIFLO-300初沉池、BIOSTYR生物滤池、MULTIFLO-300反冲洗沉淀池、UV消毒池、排海泵站组成。 (二)工艺设计 1、粗格栅 污水进入格栅井,在格栅间设置两道粗格栅以去除污水中的悬浮物质,粗格栅根据格栅前后液位差及预先设定的时间间隔及持续时间来实现自动控制,污水流经粗格栅后接着进入沉砂池泵房。沉砂池为2座PISTA20沉砂池,每个沉砂池设置1套尘砂设备(包括电动阀、砂泵、砂水分离器)。 2、细格栅 在除油沉砂池的前部设置细格栅,主要是去除粗格栅未能去除的物质,保护下游的除油沉砂单元。细格栅间隙为6 mm,满足BIOSTYR 曝气生物滤池的要求。栅宽为1500 mm,安装角度为55°。 系统由2套往复式自动细格栅和1套备用的阶梯自动格栅组成,细格栅根据

南方某城市污水处理厂工艺设计书

JIANGXI AGRICULTURAL UNIVERSITY 国土资源与环境学院水污染控制工程课程设计 题目:南方某城市污水处理厂工艺设计 所在学院:国土资源与环境学院 姓名:唐清 学号: 20113380 班级:环境工程 指导教师:王嵘 二0一三年12月15日

南方某城市污水处理厂工艺设计 唐清 摘要 本设计是关于南方某城市污水处理厂的工艺设计。污水处理规模为18×104m3/d污水来源是绝大多数为居民生活用水,少量为工业废水与其他污水。主要采用氧化沟发来处理,进水水质为CODcr 250mg/L,BOD5 125mg/L,SS 200mg/L,氨氮20mg/L。根据课程设计的原始资料及设计要求,出水水质应达到小于或等于以下要求:《城镇污水处理厂污染物排放标准》(GB18918-2002)的一般B标准。根据平面布置的原则,综合考虑各方面因素进行了污水处理厂的平面布置,根据水力损失计算对污水的高程进行了计算和布置,在最后阶段完成了对平面图和高程图及主要构筑物的绘制。 关键词:设计污水处理氧化沟

目录 第一章总论 (1) 第一节设计任务和内容 (1) 第二节基本资料 (1) 第二章水处理工艺流程说明 (3) 第三章处理构筑物的设计 (4) 第一节格栅间和泵房 (4) 第二节沉沙池 (7) 第三节初沉池 (9) 第四节曝气池 (11) 第五节二沉池 (15) 第四章主要设备说明 (18) 第五章污水厂总体布置 (19) 第一节主要构(建)筑物与附属建 (19) 第二节污水厂平面布置 (19) 参考文献 (25)

第一章总论 第一节设计任务和内容 1.对主要污水处理构筑物的工艺尺寸进行设计计算,确定污水处理厂的平面布置和高程布置。 2.完成污水处理厂平面布置图,单体构筑物图的设计计算说明书和设计图。 3.设计深度一般为初步设计的深度。 4.对工艺构筑物选型作说明。主要处理设施(格栅,沉砂池,初沉池,曝气池,二沉池)的工艺计算。污水处理厂平面和单体构筑物。第二节基本资料 (1)污水水量与水质 污水处理水量:变化系数:Kz=1.2 (2)污水厂地势基本平坦,地面标高约为19.8m(采用黄海系标高)。进水管管径为1.8m,进水管管底标高为14.8m。 (3)污水的主要来源:绝大多数为居民生活污水,少量为工业废水与其他污水。 (4)接纳水体:X江 (5)进水水量与水质 进水水量: 18×104m3/d 污水水质: CODcr 250mg/L, BOD5 125mg/L, SS 200mg/L,氨氮20mg/L (6)处理要求

某城镇污水处理厂工艺设计

一、总论 (4) 1、设计题目 (4) 2、设计资料 (4) 1.2.1城市概述 (4) 1.2.2自然条件 (4) 1.2.3规划资料 (4) 二、污水处理工艺流程说明 (5) 1、方案确定的原则 (5) 2、可行性方案的确定 (5) 3、污水处理工艺流程的确定 (5) 4、污水处理工艺流程说明 (6) 2.4.1进出污水水质 (6) 三、处理构筑物设计 (7) 1、格栅 (7) 3.1.1栅条间隙数n: (7) 3.1.2有效栅宽: (7) 3.1.3过栅水头损失: (8) 3.1.4栅后槽的总高度: (8) 3.1.5格栅的总长度: (8) 3.1.6每日栅渣量: (9) 2、污水提升泵房 (9) 3.2.1设计计算 (9)

3、沉砂池 (10) 3.3.1平流式沉沙池的设计参数 (10) 3.3.2平流式沉砂池设计 (10) 4、氧化沟 (12) 3.4.1氧化沟类型选择 (13) 3.4.2设计参数 (13) 3.4.3设计流量 (14) 3.4.4去除 (14) 3.4.5脱氮 (15) 3.4.6除磷 (16) 3.4.7氧化沟总容积及停留时间 (16) 3.4.8需氧量 (17) 3.4.9氧化沟尺寸 (18) 3.4.10进水管和出水管 (18) 3.4.11出水堰及出水竖井 (19) 5、浓缩池 (19) 3.5.1设计参数 (19) 3.5.2中心管面积 (19) 3.5.3沉淀部分的有效面积 (20) 3.5.4浓缩池有效水深 (20) 3.5.6校核集水槽出水堰的负荷 (21) 3.5.7浓缩部分所需的容积 (21)

3.5.8圆截锥部分的容积 (21) 3.5.9浓缩池总高度 (21) 四、参考文献 (23)

(完整版)污水处理厂设计本科毕业设计论文

摘要 近年来,国家和各地方对污水处理厂的排放标准要求越来越严格,中一级B标准的工艺是新建污水处理厂和老污水处理厂升级改造所面临的关键问题。本设计主要介绍了河南省濮阳市清丰县规模30000m3d的城市污水处理厂的工艺流程、各构筑物的工艺设计和平面高程设计等。 关键词:污水处理厂排放标准工艺设计

Abstract In recent years, national and local on wastewater treatment plant emissions standards is more and more strict, choose to be able to achieve stability of the urban wastewater treatment plant emissions standards and old sewage treatment plant upgrading the key problem facing. This design is introduced ZhongMouXian zhengzhou city scale for 30000m3 d city sewage treatment plant, the process flow of the various structures process design and major equipment. Keywords: sewage treatment plant emissions standards process design

目录 摘要 ............................................................... I 1、绪论 (1) 1.1 设计任务 (1) 1.1.1设计水量 (1) 1.1.2设计水质 (1) 1.2 城市概况 (1) 1.3处理程度的计算 (2) 1.3.1溶解性BOD5的去除率 (2) 1.3.2 CODcr的去除率 (2) 1.3.3 SS的去除率 (2) 1.3.4 总氮的去除率 (2) 1.3.5 总磷的去除率 (2) 2、工艺处理方案确定 (3) 2.1工艺方案选择原则 (3) 2.2 工艺方案分析 (3) 2.2.1 处理污水特点 (3) 2.2.2 选择工艺方案 (3) 2.3 工艺流程 (7) 3、污水处理构筑物 (8) 3.1 中格栅 (8) 3.1.1 设计依据: (8) 3.1.2设计参数: (8) 3.1.3设计计算 (9)