当前位置:文档之家› 框架梁及梁的构造要求

框架梁及梁的构造要求

框架梁及梁的构造要求
框架梁及梁的构造要求

C25C30C35C40

C25C30C35一级0.40.40.40.4

0.30.30.3二级0.30.30.30.30875

0.250.250.25三、四级0.250.250.250.261250.20.20.2一级0.40.40.40.4

0.30.30.3二级0.30.30.30.3

0.250.250.25三、四级0.250.250.250.25

0.20.20.2

C25C30C35C40

一级0.0014110.0015890.0017440.0019二级0.0013170.0014830.0016280.001773

三、四级0.0012230.0013770.0015120.001647非抗震0.0011290.0012710.0013960.00152一级0.0010580.0011920.0013080.001425二级0.0009880.0011120.0012210.00133

三、四级0.0009170.0010330.0011340.001235非抗震0.0008470.0009530.0010470.00114一级0.0018140.0020430.0022430.002443二级0.0016930.0019070.0020930.00228

三、四级0.0015720.001770.0019440.002117非抗震0.0014510.0016340.0017940.001954C25C30C35C400.2822220.3177780.3488890.38一级0.2634070.2965930.325630.354667二级

0.2445930.2754070.302370.329333三、四级

混凝土强度等级(支座)

HRB400HRB5003、抗震设计时,箍筋最小直径如下:一级≥10,二、三级≥8,四级≥6;当梁端纵向钢筋配筋2%时,箍筋最小直径如下:一级≥12,二、三级≥10,四级≥6。

4、抗震设计时,梁端纵向受拉钢筋的配筋率不宜大于2.5%,不应大于2.75%;当梁端受拉钢筋的大于2.5%时,受压钢筋的配筋率不应小于受拉钢筋的一半,即Asb/Ast≥0.5。

混凝土强度等级(跨中)

1、梁纵向受拉钢筋的最小配筋率

2、抗震设计时,梁端截面的底面(Asb)和顶面纵向钢筋截面面积(Ast )的比值,除按计算确定外,

一级Asb/Ast不应小于0.5,二三级Asb/Ast 不应小于0.3。

钢筋级别抗震等级

该方向截面尺寸的1/20;对圆形截面柱,不宜大于纵向钢筋所在位置柱截面弦长的1/20。7、沿梁全长箍筋的面积配筋率(Asv/(b*s))应符合下表:

钢筋级别抗震等级

混凝土强度等级

5、沿梁全长顶面和底面应至少各配置两根纵向配筋,一、二级抗震设计时钢筋直径不应小于14分别不应小于梁两端顶面和底面纵向配筋中较大截面面积的1/4;三、四级抗震设计时和非抗震钢筋直径不应小于12mm。

6、一、二、三级抗震等级的框架梁内贯通中柱的每根纵向钢筋的直径,对矩形截面柱,不宜大钢筋级别

HPB300

抗震等级HPB300

HRB400

HPB235

混凝土强度等级

梁截面宽度

0.2257780.2542220.2791110.304非抗震0.2116670.2383330.2616670.285一级0.1975560.2224440.2442220.266二级0.1834440.2065560.2267780.247三、四级0.1693330.1906670.2093330.228非抗震0.3628570.4085710.4485710.488571一级0.3386670.3813330.4186670.456二级0.3144760.3540950.3887620.423429三、四级0.290286

0.326857

0.3588570.390857非抗震

C25C30C35C400.3527780.3972220.4361110.475一级0.3292590.3707410.4070370.443333二级

0.3057410.3442590.3779630.411667三、四级0.2822220.3177780.3488890.38非抗震0.2645830.2979170.3270830.35625一级0.2469440.2780560.3052780.3325二级

0.2293060.2581940.2834720.30875三、四级0.2116670.2383330.2616670.285非抗震0.4535710.5107140.5607140.610714一级0.4233330.4766670.5233330.57二级

0.3930950.4426190.4859520.529286三、四级0.362857

0.4085710.448571

0.488571非抗震

C25C30C35C400.4233330.4766670.5233330.57一级0.3951110.4448890.4884440.532二级

0.3668890.4131110.4535560.494三、四级0.3386670.3813330.4186670.456非抗震0.31750.35750.39250.4275一级0.2963330.3336670.3663330.399二级

0.2751670.3098330.3401670.3705三、四级0.2540.2860.3140.342非抗震0.5442860.6128570.6728570.732857一级0.5080.5720.6280.684二级

0.4717140.5311430.5831430.635143三、四级0.435429

0.4902860.5382860.586286非抗震

8、在箍筋加密区范围内的箍筋肢距:一级不宜大于200mm和20倍箍筋直径的较大值,二、三级不HPB300

HRB400

HPB235

200混凝土强度等级抗震等级钢筋级别

250

250mm和20倍箍筋直径的较大值,四级不宜大于300mm。

9、截面高度大于800mm的梁,箍筋直径不宜小于8mm;对截面高度不大于800mm的梁,不宜小于6

梁截面宽度

抗震等级钢筋级别

如300宽的三级框架梁,选用HPB235箍筋时,混凝土强度等级C30,箍筋非加密区应≤180mm。300

HPB300

HRB400

HPB235

HPB300

HRB400

HPB235

梁截面宽度

混凝土强度等级

中配有计算需要的纵向受压钢筋时,箍筋直径尚不应小于d/4,d为受压钢筋最大值。

10、当梁的截面高度小于等于300时,梁中箍筋间距取150mm。

11、梁的腹板高度hw不小于450mm时,在梁的两个侧面应沿高度配置纵向构造钢筋。每侧纵向构(不包括梁上、下部受力钢筋及架立钢筋)的间距不宜大于200mm,截面面积不应小于腹板截面(bhw)的0.1%,但当梁宽较大时可以适当放松。

12、梁上部钢筋水平方向的净间距不应小于30mm和1.5d;梁下部钢筋水平方向的净间距不应小于d。当下部钢筋多于2层时,2层以上钢筋水平方向的中距应比下面2层的中距增大一倍;各层钢筋净间距不应小于25mm和d,d为钢筋的最大直径。

13、当梁端按简支计算但实际受到部分约束时,应在支座区上部设置纵向构造钢筋。其截面面积于梁跨中下部纵向受力钢筋计算所需截面面积的1/4,且不应小于2根。该纵向构造钢筋自支座边内伸出长度不应小于lo/5,lo为梁的计算跨度。

14、非抗震设计时,承受弯矩和剪力的梁,当梁的剪力设计值大于0.7ftbho时,其箍筋的面积配大于等于0.24ft/fyv。

15、非抗震设计时,承受弯矩、剪力和扭矩的梁,其箍筋的面积配箍率应大于等于0.28ft/fyv。向钢筋的面积配筋率应满足梁内受扭纵筋的最小配筋率要求。沿截面周边布置受扭纵筋的间距不200mm及梁截面短边长度;除应在梁截面四角设置受扭纵向钢筋外,其余受扭纵筋宜沿截面周边称布置。受扭纵向钢筋应按受拉钢筋锚固在支座内。

中)

C40

0.30875

0.26125

0.21375

0.3

0.25

0.2

除按计算确定外,

筋配筋率大于

钢筋的配筋率

小于14mm,且

非抗震设计时

不宜大于柱在

m。

三级不宜大于小于6mm。梁

纵向构造钢筋板截面面积

应小于25mm和层钢筋之间的

面面积不应小支座边缘向跨

面积配箍率应

/fyv。受扭纵间距不应大于面周边均匀对

相关主题
文本预览