Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin Cable guide for Mitsubishi HMI range
This guide has been created to aid the identification and correct matching of communication cables, HMIs and PLCs.
Title:Cable guide for Mitsubishi HMI range Page 1 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin Contents
Programming FX 25/30/40/50 DU (3)
Programming F900GOT Series HMIs (4)
Programming A870GOT (5)
Programming MAC 10/12 (6)
Programming MAC 40+ (7)
Programming E Series HMIs, MAC 10CM/50/50CM/90 and CM 10 (8)
FX-10DU to PLC (9)
FX-20DU to PLC (10)
FX-25DU to PLC (11)
FX-30/40/50DU and F900GOT Series HMIs to PLC (12)
MAC 10/12 to PLC (14)
E Series HMIs, MAC 10CM/40+ and CM 10 to PLC (15)
MAC 50/50CM/90 to PLC (17)
A870GOT to PLC (19)
E-Series HMIs to GE Fanuc (21)
E-Series HMIs to Omron (22)
E-Series HMIs to SIMATIC S5 (23)
E-Series HMIs to SIMATIC S7 (24)
E-Series HMIs to Allen Bradley DF1 (25)
E-Series HMIs to Allen Bradley DH485 (26)
E-Series HMIs to FREQROL FR-A/FR-E (27)
Part numbers (28)
Title:Cable guide for Mitsubishi HMI range Page 2 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin Programming FX 25/30/40/50 DU
Title:Cable guide for Mitsubishi HMI range Page 3 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 4 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal Programming F900GOT Series HMIs
9-pin D-sub female 25-pin D-sub male
ADAPTER
25 to 9 pin adapter.
Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin
Programming A870GOT
Title:Cable guide for Mitsubishi HMI range Page 5 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin
Programming MAC 10/12
MiniDIN 8-pin male MiniDIN 8-pin male3m.
Other
Voltage feed, +5VDC, of the MAC 10/12 is done internally by the SC-06N.
Title:Cable guide for Mitsubishi HMI range Page 6 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 7 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal Programming MAC 40+
25-pin D-sub male
25-pin D-sub male
MAC 40+ CAB
Cable between MAC 40+ and SC-06N when programming of MAC 40+. Length PERIPHERAL PSU Power supply unit.
Other
Voltage feed, +5VDC, of the MAC 40+ is done internally by the SC-06N
Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin Programming E Series HMIs,
MAC 10CM/50/50CM/90 and CM 10
Other Voltage feed, +5VDC, of the CM10 and MAC10 CM is done by connecting a PLC (FX or A range) to the RS422 port, se page 14.
Title:Cable guide for Mitsubishi HMI range Page 8 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 9 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal FX-10DU to PLC
25-pin D-sub female MiniDIN 8-pin male
FX-20P-CADP
Adapter cable used with FX-20P-CAB to connect FX-10DU to FX0/FX0S/FX0N/FX2N PLCs
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 10 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal FX-20DU to PLC
25-pin D-sub female MiniDIN 8-pin male
FX-20P-CADP
Adapter cable used with FX-20DU-CAB/EN to connect FX-20DU to FX0/FX0S/FX0N/FX2N PLCs
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 11 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal FX-25DU to PLC
25-pin D-sub female MiniDIN 8-pin male
FX-20P-CADP
Adapter cable used with FX-40DU-CAB/EN to connect FX-25DU to FX0/FX0S/FX0N/FX2N PLCs
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 12 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal FX-30/40/50DU and F900GOT Series HMIs to PLC
25-pin D-sub female MiniDIN 8-pin male
FX-20P-CADP
Adapter cable used with FX-40DU-CAB/EN to connect FX-30/40/50DU,
F940GOT to FX0/FX0S/FX0N/FX2N PLCs
Continued over the page………..
Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin FX-30/40/50DU and F940GOT to PLC ….continued…….
Title:Cable guide for Mitsubishi HMI range Page 13 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 14 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal MAC 10/12 to PLC
25-pin D-sub male 25-pin D-sub male
25-pin D-sub female MiniDIN 8-pin male
CADP)
FX-20P-CADP
Adapter cable used with
MAC 40+CAB to connect MAC 10/12 to FX PLC
Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin
E Series HMIs, MAC 10CM/40+ and CM 10 to PLC
Continued over the page………..
Title:Cable guide for Mitsubishi HMI range Page 15 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 16 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal
E Series HMIs, MAC 10CM/40+ and CM 10 to PLC….continued…….
25-pin D-sub male
MiniDIN 8-pin male
FX-20P-CAB
Cable between MAC 40+, E Series and FX0/FX0S/FX0N/FX2N
Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin
MAC 50/50CM/90 to PLC
Continued over the page………..
Title:Cable guide for Mitsubishi HMI range Page 17 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 18 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal MAC 50/50CM/90 to PLC…..continued…..
15-pin D-sub male 25-pin D-sub male
MAC-CAB
Cable between MAC 50/50CM/90 and 1) FX, AnS, A
2) FX0/FX0S/FX0N/FX2N (together with adapter cable FX-20P-CADP)
Travellers Lane, Hatfield, Herts, AL10 8XB, UK
Author: ?sa Nilsson
Databank - Technical Bulletin
A870GOT to PLC
Continued over the page………..
Title:Cable guide for Mitsubishi HMI range Page 19 of 27 Keywords:Cable guide
Human Machine Interface (HMI)
Operator Terminal
Travellers Lane, Hatfield, Herts, AL10 8XB, UK Author: ?sa Nilsson
Databank - Technical Bulletin
Title:
Cable guide for Mitsubishi HMI range Page 20 of 27
Keywords:
Cable guide
Human Machine Interface (HMI)Operator Terminal
A870GOT to PLC…….continued…….
15-pin male
A870GOT bus connector(AnS)
A1SCxxNB
Cable between A870GOT and AnS bus connection.
0.45m - A1SC05NB 3m - A1SC30NB