当前位置:文档之家› 智能变电站合并单元技术规范(清晰版)讲解(汇编)

智能变电站合并单元技术规范(清晰版)讲解(汇编)

智能变电站合并单元技术规范(清晰版)讲解(汇编)
智能变电站合并单元技术规范(清晰版)讲解(汇编)

Q / GDW 212 — 2008

ICS 29.240

国家电网公司企业标准 Q / GDW 426 — 2010

智能变电站合并单元技术规范

The technical specification for merging unit in Smart Substation

2010-××-××发布

2010-××-××实施

国家电网公司发布

Q/GDW

Q / GDW 426 — 2010

I

目次

前言···································································································································································II 1 范围·····························································································································································1 2 引用标准······················································································································································1 3 基本技术条件··············································································································································1 4 主要性能要求·········································································································

.....................................3 5 安装要求......................................................................................................................................................4 6 技术服务......................................................................................................................................................4 编制说明.. (7)

Q / GDW 426 — 2010

II

前言

由于现行国家标准、行业标准、企业标准和IEC 标准等未统一智能变电站合

并单元的技术要求等内容,为使智能变电站合并单元选型、设备采购等工作有所遵循,特编制本标准。

本标准提出的技术性能参数基于国内外变电站合并单元的设计、制造和运行经验,并结合智能变电站的技术导则及设计技术规范而提出。由于智能变电站技术仍处于发展阶段,本规范的相关技术原则将随着技术的发展与成熟逐步修订和完善。

本标准由国家电网公司基建部提出并负责解释。

本标准由国家电网公司科技部归口。

本规范主要起草单位:四川电力设计咨询有限责任公司,四川电力试验研究院、中国电力工程顾问集团公司、江苏省电力设计院、河南省电力勘测设计院、山东电力工程咨询院有限公司。

本规范参与起草单位:浙江省电力设计院、陕西省电力设计院、安徽省电力设计院、国网电力科学研究院、浙江电力试验研究院。

本标准主要起草人:吴家林、郑旭、李琪林、陈志蓉、曾健、张国钦、潘峰、秦华、浦知新、李娴、刘中元、信珂、张玉军、黄国方、阮黎翔、高亚栋、林泽源、邵松涛、雷民。

Q / GDW 426 — 2010

1 智能变电站合并单元技术规范

1 范围

本规范规定了智能变电站合并单元的功能要求、安装要求和技术服务等内容。

本规范适用于国家电网公司系统内智能变电站的新建工程,其它扩建、改建工程可参照执行。 2 引用标准

下列标准所包含的条文,通过在本规范书中引用而构成本规范书的条文。所示标准均应采用最新有效版本。

GB 16836-2003 量度继电器和保护装置安全设计的一般要求

GB/T 2423 电工电子产品环境试验

GB/T 3047.3 高度进制为20mm 的插箱、插件基本尺寸系列

GB 4208—1993 外壳防护等级(IP 代码)

GB/T 4798.3—1990 电工电子产品应用环境条件有气候防护场所固定使用

GB/T 14598.27—2008 量度继电器和保护装置第27部分:产品安全要求

GB/T 17626 电磁兼容试验和测量技术

GB/T 20840.7—2007 互感器第7部分:电子式电压互感器

GB/T 20840.8—2007 互感器第8部分:电子式电流互感器

DL/T 860 变电站通信网络和系统

Q/GDW 383—2009 智能变电站技术导则

Q/GDW 393—2009 110(66)kV ~220kV 智能变电站设计技术规范

Q/GDW 394—2009 330kV ~750kV 智能变电站设计技术规范

IEC 61588 precision clock synchronization protocol for networked measurement and control system 网络化测量同步系统精确时钟同步协议

3 基本技术条件

3.1 使用环境条件

海拔高度:≤1000m ;

环境温度:-5℃~+45℃(户内);

–25℃~+55℃(户外);

最大日温差:25K ;

最大相对湿度:95%(日平均);

90%(月平均);

大气压力:86kPa ~106kPa ;

抗震能力:水平加速度0.30g ,垂直加速度0.15g ;

注:以上环境条件可根据具体工程调整。

3.2 主要技术指标

3.2.1 电源

a )基本参数

Q / GDW 426 — 2010

2

1)额定电压: DC220/ DC110V ; 2)允许偏差:-20%~+15%; 3)纹波系数:不大于5%。

b )拉合直流电源以及插拔熔丝发生重复击穿火花时,装置不应误输出;直流电源回路出现各种异

常情况(如短路、断线、接地等)时,装置不应误输出。

c )按GB/T 7261—1987中15.3的规定进行直流电源中断20ms 影响试验,装置不应误输出。

d )将输入直流电源的正负极性颠倒,装置无损坏,并能正常工作。

e )装置加上电源、断电、电源电压缓慢上升或缓慢下降,装置均不应误输出;当电源恢复正常后,

装置应自动恢复正常运行。

f )当正常工作时,装置功率消耗不大于40W 。

3.2.2 绝缘性能

a )绝缘电阻

在试验的标准大气条件下,装置的外引带电回路部分和外露非带电金属部分及外壳之间,以及电气上无联系的各回路之间,用1000V 的直流兆欧表测量其绝缘电阻值,应不小于20M Ω。 b )介质强度

1)在试验的标准大气条件下,装置应能承受频率为50Hz ,历时1min 的工频耐压试验而无击

穿闪络及元器件损坏现象;

2)工频试验电压值按表3.2-1选择。也可以采用直流试验电压,其值应为规定的工频试验电

压值的1.4倍;

表3.2-1 各回路试验电压要求

被试回路

额定绝缘电压(V )

试验电压 AC(V )

整机引出端子和背板线——地

>60~250 2000 直流输入回路——地>60~250 2000 信号输出触点——地>60~250 1000 无电气联系的各回路之间>60~250 2000 整机带电部分——地

≤60

500

3)试验过程中,任一被试回路施加电压时其余回路等电位互联接地。

c )冲击电压

在试验的标准大气条件下,装置的直流输入回路、交流输入回路、信号输出触点等诸回路对地,以及回路之间,应能承受1.2/50μs 的标准雷电波的短时冲击电压试验。当额定绝缘电压大于60V 时,开路试验电压为5kV ;当额定绝缘电压不大于60V 时,开路试验电压为1kV 。

3.2.3 耐湿热性能

装置应能承受GB/T2423.9规定的恒定湿热试验。试验温度为+40℃±2℃,相对湿度为(93±3)%,试验持续时间48h 。在试验结束前2h 内,用1000V 直流兆欧表,测量各外引带电回路部分对外露非带电金属部分及外壳之间、以及电气上无联系的各回路之间的绝缘电阻值应不小于1.5M Ω;介质强度不低于规定值的75%。

3.2.4 抗干扰性能

合并单元应通过表3.2-2中的电磁兼容类试验。

Q / GDW 426 — 2010

3

表3.2-2 抗干扰性能试验和要求

1 静电放电抗扰度17626.4—级

2 射频电磁场辐射抗扰度17626.4—级

3 电快速瞬变脉冲群抗扰度17626.4—级

4 浪涌(冲击)抗扰度17626.4—级

5 射频场感应的传导骚扰抗扰度17626.4—级

6 工频磁场抗扰度17626.4—级

7 脉冲磁场抗扰度17626.4—级

8 阻尼振荡磁场抗扰度17626.4—级 9

振荡波抗扰度17626.4—级

注:评估等级采用A 。

3.2.5 结构、外观及其他

a )机箱尺寸应符合GB/T3047.3的规定,高度宜采用6U 。

b )装置的不带电金属部分应在电气上连成一体,并具备可靠接地点。

10KV-箱式变电站技术标准

10KV 箱式变电站技术标准 引用标准 下列标准所包含的条文,通过本技术条件的引用而构成本技术的条文。本技术条件实施中,所示版本均为有效。所有标准都会被修订,使用本技术条件的各方应探讨使用下列标准最新版本的可能性。GB/T17467—1998 《高压/低压预装式变电站》GB1094.1-2-1996 《电力变压器》 GB/T6451—1995 《三相油浸电力变压器技术参数和要求》 GB/T16927.1—2—1997 《高压试验技术》 GB311.1—6—1997 《电力变压器》 ZBK40001—89 《组合式变电站》 GB763—1990 《交流高压电器在长期工作时的发热》 GB1984—89 《交流高压断路器》 GB3804—90 《3—63KV 交流高压负荷开关》 GB3906—91 《3—35KV 交流金属封闭开关设备》 GB/T5582—93 《高压电力设备外绝缘污秽等级》 GB311.2—2002 《高压输变电设备的绝缘配合使用导则》 GB3804—90 《3~63KV 交流高压负荷开关》 GB4109—88 《高压套管技术条件》 DL/T537—93 《6~35KV 箱式变电站订货技术条件》 GB/T18858.1—2002 《低压开关设备和控制设备》 GB/T4942.2—1993 《低压电器外壳防护等级》 GB/T14598—2002 《电气继电器》 GB7251.1—2005 《低压成套开关设备》 GB7328—87 《电力变压器和电抗器的声级测定》 GB/T17215—2002 《1和2级静止式交流有功电能表》 GB4208—93 《外壳防护等级》(IP 代码) GB/T4942.2—1993 《低压电器外壳防护等级》 10KV 箱式变电站供货范围 1.YXB-10箱式变电站供货范围:(KVA) 30、50、63、80、100、125、160、200、250、315、400、500、630、800、1000、1250、1600。 2. 使用条件 预装式变电站可以在以下使用条件、在额定容量下持续运行。 a. 使用位置:户外 b. 海拔高度:≤1200m c. 环境温度: 最高气温:40℃ 最热月平均温度:30℃ 最高年平均温度:20℃ 最低气温:-40℃ d. 相对湿度 在25℃时,空气相对湿度不超过95%,月平均不超过90%。 e. 安装环境 安装环境应无明显污秽、无爆炸、腐蚀性气体和粉尘,安装场所应无强烈震动冲击;地震引发的地面加速度ag ,水平方向低于3m/s2,垂直方向低于1.5m/s2。

智能变电站继电保护题库

智能变电站继电保护题库 第一章判断题 1.智能变电站的二次电压并列功能在母线合并单元中实现。 2.智能变电站内智能终端按双重化配置时,分别对应于两个跳闸线圈,具有分相跳闸功能;其合闸命令输出则并接至合闸线圈。 3.对于500kV智能变电站边断路器保护,当重合闸需要检同期功能时,采用母线电压合并单元接入相应间隔电压合并单元的方式接入母线电压,不考虑中断路器检同期。 4.任意两台智能电子设备之间的数据传输路由不应超过4个交换机。当采用级联方式时,允许短时丢失数据。5.智能变电站内双重化配置的两套保护电压、电流采样值应分别取自相互独立的合并单元。 6.双重化配置保护使用的GOOSE(SV)网络应遵循相互独立的原则,当一个网络异常或退出时不应影响另一个网络的运行。 7.智能变电站要求光波长1310nm光纤的光纤发送功率为-20dBm ~-14dBm,光接收灵敏度为-31dBm ~-14dBm。8.智能变电站中GOOSE开入软压板除双母线和单母线接线外启动失灵、失灵联跳开入软压板既可设在接收端,也可设在发送端。 9.有些电子式电流互感器是由线路电流提供电源。这种互感器电源的建立需要在一次电流接通后迟延一定时间。此延时称为“唤醒时间”。在此延时期间,电子式电流互感器的输出为零。 10.唤醒电流是指唤醒电子式电流互感器所需的最小一次电流方均根值。 11.温度变化将不会影响光电效应原理中互感器的准确度。 12.长期大功率激光供能影响光器件的寿命,从而影响罗氏线圈原理中电子式互感器的准确度。 13.合并单元的时钟输入只能是光信号。 14.用于双重化保护的电子式互感器,其两个采样系统应由不同的电源供电并与相应保护装置使用同一直流电源。 15.电子式互感器采样数据的品质标志应实时反映自检状态,不应附加任何延时或展宽。 16.现场检修工作时,SV采样值网络与GOOSE网络可以联调。 17.GOOSE跳闸必须采用点对点直接跳闸方式。 18.220kV智能变电站线路保护,用于检同期的母线电压一般由母线合并单元点对点通过间隔合并单元转接给各间隔保护装置。 19.智能变电站母线保护按双重化进行配置。各间隔合并单元、智能终端均采用双重化配置。 20.智能变电站采用分布式母线保护方案时,各间隔合并单元、智能终端以点对点方式接入对应母线保护子单元。 21.智能变电站保护装置重采样过程中,应正确处理采样值溢出情况。 22.与传统电磁感应式互感器相比,电子式互感器动作范围大,频率范围宽。

智能变电站功率振荡解列装置通用技术规范(范本)

智能变电站功率振荡解列装置通用技术规范(范本)

本规范对应的专用技术规范目录 智能变电站功率振荡解列装置采购标准 技术规范(范本)使用说明 1、本标准技术规范(范本)分为通用部分、专用部分。 2、项目单位根据需求选择所需设备的技术规范(范本),通用技术规范(范本)部分条款及专用技术规范(范本)部分固化的参数原则上不能更改。 3、项目单位应按实际要求填写“项目需求部分” 。如确实需要改动以下部分,项目单位应填写专用部分“项目单位技术差异表”并加盖该网、省公司物资部(招投标管理中心)公章,与

辅助说明文件随招标计划一起提交至招标文件审查会: ①改动通用部分条款及专用部分固化的参数; ②项目单位要求值超出标准技术参数值; ③需要修正污秽、温度、海拔等条件。 经标书审查会同意后,对专用部分的修改形成“项目单位技术差异表” ,放入专用部分中,随招标文件同时发出并视为有效,否则将视为无差异。 4、对扩建工程,项目单位应在专用部分提出与原工程相适应的一次、二次及土建的接口要求。 5、技术规范(范本)的页面、标题、标准参数值等均为统一格式,不得随意更改。 6、投标人逐项响应专用技术规范(范本)部分中“ 1 标准技术参数表”、“ 2 项目需求部分”和“ 3 投标人响应部分”三部分相应内容。填写投标人响应部分,应严格按招标文件专用技术规范(范本)部分的“招标人要求值”一栏填写相应的招标文件投标人响应部分的表格。投标人填写技术参数和性能要求响应表时,如有偏差除填写“技术偏差表”外,必要时应提供相应试验报告。 7、一次设备的型式、电气主接线和一次系统情况对二次设备的配置和功能要求影 响较大,应在专用部分中详细说明

10kV变电所系统技术规范书

地面10kV变电所高压开关柜技术规格书 编制: 审核: 二0一九年元月十六日

审查表 矿机电科:年月日矿机电矿长:年月日矿总工程师:年月日矿长:年月日公司机电部:年月日公司分管副总:年月日公司总工程师:年月日 审查意见:

目录 1、供货范围 2、项目概况 3、总的要求 结构及性能要求 4、项目环境 5、技术文件 6、其他要求 7、试验 8、质量保证和管理 9、技术服务、设计联络、工厂检验和监造 10、供方提供必须的备品备件、专用工具 1 供货范围 本表仅为10KV变电所综合自动化装置供货范围的主要项目,卖方应根据买方的技术条件提出详细的设备清单。 10KV站: 序号名称型号 单 位 数 量 备注 1 通信测控屏(每面 柜包括) 面 1 通讯管理机单元台 1 GPS对时单元台 1 以太网交换机台 1 公共测控单元 15路电流测量、32路电压 测量、56路遥信量、16路 遥控量、8路直流测量 台 1 电量采集单元台 1 预留开孔位置UPS单元台 1 预留开孔位置 2 10KV光纤差动保 护测控装置(包括 光纤接线盒及尾 台13 就地分散安装

纤) 3 10KV三段电流保 护测控装置 台 5 4 10KV变压器保护 装置 台 2 就地分散安装 5 10KV电容器保护 装置 台 2 就地分散安装 6 10KV分段保护自 投装置(含备自投) 台 1 就地分散安装 7 10KV PT并列测 控单元 台 1 就地分散安装 8 微机消谐装置SMR-WXB 台 2 就地分散安装 9 以太网交换机台 1 就地分散安装 10 五防及监控主机台 1 11 监控、五防等软件套 1 12 五防锁具及配件套 1 13 打印机台 1 14 备品备件 套 1 CPU板2块,测控装 置一台,电源板一块 15 网络连接电缆套 1 满足工程需要 16 操作台台 1 2 项目概况 本变电所的二次设备采用GCSAS型变电站综合自动化装置,完成变电站的监控及保护功能,同时向上级调度单位提供变电站运行状况信息,完成远动系统RTV(远方终端单元)功能。其保护型式为: 10kV保护: 10kV馈出线设电流速断保护和过电流保护,速断保护为主保护,过流保护为后备保护。在10kV馈出线上安装FRD-CT型零序电流互感器和FRD-XL单相接地保护装置,构成单相接地保护,单相接地保护动作于信号。 电容器柜设无时限过电流,保护动作于跳闸。过电压保护、单相接地保护。 低压馈线利用开关自身的过流脱扣器实现保护。10KV主接线采用单母线分段接线;400V主接线采用采用单母线分段接线。 3、总的要求 3.1需知 3.1.1供货方(或供货厂,下同)必须有权威机构颁发的ISO-9000系列的认证证书或等同的质量保证体系认证证书及华北电网有限公司进网许可证。供货方或供货厂(包括分包厂)应设计、制造和提供过同类设备,且使用条件应与本工程相类似,或按较规定的条件更严格,至少有3台套3年以上的商业运行经验。 3.1.2供货方应仔细阅读招标文件。供货方提供的设备技术规范应与本协议书中提出的要求相一致,供货方也可以推荐满足本协议书要求的类似定型产品,但必须提出详细的技术偏差。 3.1.3本书提出了对设备本体及其附属设备的技术要求。主要包括设备的使用条件、主要技术参数、结构、性能、试验及所需技术资料等方面的内容。

最新变电站保护装置合并单元简介

变电站保护装置合并单元简介 传统变电站中所需要的电气量都通过电缆直接接入常规互感器 的二次侧电流、电压,再通过保护、测控等装置自身的采样模块实现对模拟量的采样的A/D转换。智能变电站则是通过某个装置专门完成电气量的采样和A/D转换,再通过光纤将采样的数字量直接传送给保护、测控装置。这个专门的装置就是我们本期要了解的“合并单元”。 1、功能 合并单元(Merging Unit)的功能主要是将互感器输出的电压、电流信号合并,输出同步采样数据,并为互感器提供统一的输出接口,使不同类型的互感器于不同类型的二次设备之间能够互相通信。 按照功能,合并单元一般可以分为间隔合并单元和母线合并单元。 间隔合并单元用于线路、变压器和电容器等间隔电气量的采集,只发送本间隔的电气量数据。一般包括三相电压Uabc,三相保护电流Iabc、三相测量用电流I、同期电压UL、零序电压U0、零序电流I0。对于双母线接线的间隔,合并单元根据本间隔隔离开关的位置,自动实现电压切换的功能。 母线合并单元一般采集母线电压或者同期电压,在需要电压并列时,可通过软件自动实现个母线电压的并列。

目前智能站中合并单元的采样频率和输出频率统一为4kHz,即每工频周期80个采样点,这可以保护、测量装置的需求。对于计量用的合并单元需要专门设计,其采样和输出频率为12.8kHz。 2、技术原理 (1)电气量采集 由互感器输入合并单元的电气量可能是模拟量,也可能是数字量。 对于传统互感器输出的模拟量,模拟信号通过电缆输入合并单元,经过隔离变换、低通滤波后进入CPU进行A/D转换后,变为数字量输出至SV接口。 对于电子式互感器输出地数字量,合并单元有同步和异步两种方式。 同步方式:合并单元向个电子式互感器发送同步脉冲信号,电子式互感器接收到同步信号后,对一次电气量开始采集处理,并将采样数字量发送至合并单元。

变电站五防系统改造技术规范书

35kV变电站新增五防系统 技术规范书 生产设备管理部 2015年3月 目录

1 总则 (2) 2项目概况及环境条件 (3) 2.1项目概况 (3) 2.2 使用条件 (3) 3 技术要求 (5) 3.1 微机五防系统的组成和适用范围 (5) 3.2. 微机五防功能和技术要求 (8) 4 产品质量保证及验收 (12) 4.1 现场验收 (12) 4.2 现场服务及售后服务 (13) 5 培训 (12) 1 总则

1.1 本规范适用于35kV及以上电压等级变电站新增微机五防系统,五防系统的功能设计、结构、性能、安装和试验等方面的技术要求。 1.2 本规范提出的是最低限度的要求,并未对一切技术细节作出规定,也未充分引述有关标准和规范的条文,投标方应提供符合本规范和工业标准的优质产品。 1.3 如果投标方没有以书面形式对本规范的条文提出异议,则表示投标方提供的设备完全符合本规范的要求;如有异议,应在报价中以“对规范的意见和同规范的差异”为标题的专门章节中加以详细描述。 1.4 本规范所使用的标准如遇与投标方所执行的标准不一致按较高的标准执行。 1.5 本规范经招、投标双方确认后作为订货合同的技术附件,与合同正文具有同等效力。 1.6 供方职责 供方的工作范围将包括但不限于此内容。 1.6.1提供标书内所有设备及设计说明书及制造方面的说明。 1.6.2提供国家或电力行业级检验检测机构出具的型式试验报告,以便确认供货设备能否满足所有的性能要求。 1.6.3提供与投标设备版本相符的安装及使用说明书、维护手册。 1.6.4提供试验和检验的标准,包括试验报告和试验数据,电磁兼容报告。 1.6.5提供图纸,制造和质量保证过程的一览表以及厂商推荐的技术方案、设备布置、安装接线图和标书规定的其他资料。 1.6.6提供设备管理和运行所需有关资料,及同类设备运行成功的供货记录(安装地点、投运时间、运行情况等)。 1.6.7所提供设备应发运到规定的目的地。 1.6.8如标准、规范与本标书的技术规范有明显的冲突,则供方应在制造设备前,用书面形式将冲突和解决办法告知买方,并经买方确认后,才能进行设备制造。1.6.9在更换所用的准则、标准、规程或修改设备技术数据时,供方有责任接受买方的选择。 1.6.10 投标方应保证所供货的微机五防系统不存在侵犯第三方知识产权问题。1.6.11投标方有合作伙伴时,在投标文件中应说明与合作伙伴的分工。未经需方同

10kV箱式变电站技术标准规范

10kV箱式变电站技术规范

目录 1 规范性引用文件 (1) 2 结构及其他要求 (2) 3 标准技术参数 (4) 4 使用环境条件表 (7) 5 试验 (8)

10kV箱式变电站技术规范 1 规范性引用文件 下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本适用于本文件。 GB311.1绝缘配合第1部分:定义、原则和规则 GB1094.1电力变压器第1部分:总则 GB1094.2电力变压器第2部分:液浸式变压器的温升 GB1094.3电力变压器第3部分:绝缘水平、绝缘试验和外绝缘空气间隙 GB1094.4电力变压器第4部分:电力变压器和电抗器雷电冲击和操作冲击试验导则 GB1094.5电力变压器第5部分:承受短路的能力 GB/T 1094.7电力变压器第7部分:油浸式电力变压器负载导则 GB/T1094.10电力变压器第10部分:声级测定 GB1208电流互感器 GB1984高压交流断路器 GB1985高压交流隔离开关和接地开关 GB2536电工流体变压器和开关用的未使用过的矿物绝缘油 GB2900.15电工术语变压器、互感器、调压器和电抗器 GB 3804 3.6kV~40.5kV高压交流负荷开关 GB/T4109交流电压高于1000V的绝缘套管 GB 4208外壳防护等级(IP代码) GB/T4585交流系统用高压绝缘子的人工污秽试验 GB5273变压器、高压电器和套管的接线端子 GB/T 6451油浸式电力变压器技术参数和要求 GB/T7252变压器油中溶解气体分析和判断导则 GB/T7354局部放电测量 GB/T7595运行中变压器油质量 GB10230.1分接开关第1部分性能要求和试验方法 GB 10230.2分接开关第2部分:应用导则 GB13499电力变压器应用导则 GB/T 13729远动终端设备 GB/T 14048.1低压开关设备和控制设备第1部分:总则 GB/T 14048.2低压开关设备和控制设备第2部分:断路器 GB 16926 交流高压负荷开关熔断器组合电器 GB16847保护用电流互感器暂态特性技术要求 GB16927.1高压试验技术第1部分:一般定义及试验要求 GB16927.2高压试验技术第2部分:测量系统 GB/T 16935.1低压系统内设备的绝缘配合第1部分:原理、要求和试验 GB/T17467高压/低压预装式变电站 GB/T17468电力变压器选用导则 GB 20052三相配电变压器能效限定值及能效等级

智能变电站合并单元技术规范(清晰版)讲解(汇编)

Q / GDW 212 — 2008 ICS 29.240 国家电网公司企业标准 Q / GDW 426 — 2010 智能变电站合并单元技术规范 The technical specification for merging unit in Smart Substation 2010-××-××发布 2010-××-××实施 国家电网公司发布 Q/GDW Q / GDW 426 — 2010 I 目次 前言···································································································································································II 1 范围·····························································································································································1 2 引用标准······················································································································································1 3 基本技术条件··············································································································································1 4 主要性能要求·········································································································

箱式变电站技术规格书.docx

山东明珠建设集团有限公司IOKV 箱式变电站技术规格书 需方:山东明珠建设集团有限公司 供方:

技术规格书 1 ?概述 本规范书适用于仅限于山东明珠建设集团兴隆小区三期配套工程。本次订购的箱式变电站为 2X63OKVA —台,本技术规范书所使用的标准如与供方所执行的标准不一致时,按较高的标准执行。合同执行过程中,若国家标准更新,应按最新标准执行。 本设备技术规范书经需方、供方确认后作为订货合同的技术附件,与正文合同具有同等的法律效力。 供方保证需方购买的合同产品不会引起第三方的侵权之诉,否则供方必须弥补需方由此发生的任何费用及损失。 本规范书与图纸矛盾时以规范书为准,需方保留对本协议书提出补充要求和修改的权利;供方应承诺予以配合,具体内容由供需双方协商确定。 本设备技术规范书未尽事宜,由供需双方协商确定。 1.1适用范围 1.1.1. 本技术规格书适用于投标方提供的箱式变电站的设计、制造、工厂试验、交付、现场的安装指导、监督、现场试验及运行工作。 1.1. 2. 本技术规格书未说明,但又与设计、制造、试验、运输、包装、保管、安装、运行和维护有关的技术要求,按本文规定的有关标准执行。 2.箱式变电站应包括: 2.1箱内所有高压配电装置; 2.2箱内所有低压配电装置; 2.3电力变压器(S13- 630KVA 2台). 2.4备品、备件; 2.5箱内其它的相关设施、元器件。 3 .技术规格 3.1. 执行标准 产品的设计制造和调试符合现行的国际电力行业标准,IEC有关标准要求 GB3906 3-35KV交流金属封闭开关 GB11022 高压开关设通用技术条

GB1985交流咼压隔离开关和接地开关 GB1207电压互感器 GB6450-1986《干式电力变压器》 GB/T10228-1997《干式电力变压器技术参数和要求》 JB/T10088-1999《6~220KV级电压器声级》 ZBK40001-89《组合式变电站》 GB1208电流互感器 GB7251《低压成套开关设备》 GB14048.1《低压开关设备和控制设备总则》 GB14048.2《低压开关设备和控制设备低压断路器》GB4942.2《低压电器外壳防护等级》 GB3047《面板、架和柜的基本尺寸》 GB9466《低压成套开关设备基本试验方法》 GB2681《电工成套装饰中的导线颜色》 箱式变电站中的电力变压器应符合本GB/T10228-1997中的有关规定及国家部)标准;箱式变电站中的各种电器设备应分别符合相应的现行国家(或部)标准。 3.2箱式变电站设备技术要求 321机械、电气性能 1.高压柜的主要技术参数 ⑴额定电压:10KV ⑵ 额定绝缘电压:12KV ⑶ 额定工频耐受电压:42KV,Imin 75KV ⑷ 额定雷电冲击耐受电压: a)主母线电流:630A b)支母线电流:200A C)额定频率:50HZ d)额定短时耐受电流:31.5KA, 4S f)内部燃弧耐受电流:40KA,1S 50KA,0.5S

10KV箱式变电站技术标准

引用标准 下列标准所包含的条文,通过本技术条件的引用而构成本技术的条文。本技术条件实施中,所示版本均为有效。所有标准都会被修订,使用本技术条件的各方应探讨使用下列标准最新版本的可能性。 GB/T17467—1998 《高压/低压预装式变电站》 GB1094.1-2-1996 《电力变压器》 GB/T6451—1995 《三相油浸电力变压器技术参数和要求》 GB/T16927.1—2—1997 《高压试验技术》 GB311.1—6—1997 《电力变压器》 ZBK40001—89 《组合式变电站》 GB763—1990 《交流高压电器在长期工作时的发热》 GB1984—89 《交流高压断路器》 GB3804—90 《3—63KV交流高压负荷开关》 GB3906—91 《3—35KV交流金属封闭开关设备》 GB/T5582—93 《高压电力设备外绝缘污秽等级》 GB311.2—2002 《高压输变电设备的绝缘配合使用导则》 GB3804—90 《3~63KV交流高压负荷开关》 GB4109—88 《高压套管技术条件》 DL/T537—93 《6~35KV箱式变电站订货技术条件》 GB/T18858.1—2002 《低压开关设备和控制设备》 GB/T4942.2—1993 《低压电器外壳防护等级》 GB/T14598—2002 《电气继电器》 GB7251.1—2005 《低压成套开关设备》 GB7328—87 《电力变压器和电抗器的声级测定》 GB/T17215—2002 《1和2级静止式交流有功电能表》 GB4208—93 《外壳防护等级》(IP代码) GB/T4942.2—1993 《低压电器外壳防护等级》

25-110kV变电站环境整治技术规范书

110kV XX变电站环境整治 技术规范书 工程项目:变电站环境综合整治(XX变)

目 1总则 2工程概况 3工程整治要求 4施工工艺标准 附件一差异表 附件二投标人需要说明的其他问题

1总则 1.1本规范书适用于110kVXX变电站建筑物及生产环境施工整治,它提出110kVXX变电站建筑物及生产环境施工整治规模、工艺等方面的技术要求。供方可提供高质量的产品和附件来满足规范书中设计及工艺的标准要求。1.2本规范书提出的是最低限度的要求,并未对一切技术细节 作出规定,也未充分引述有关标准和规范的条文,供方应保证提供符合本规范书和工业标准的优质产品。 1.3供方应以书面形式对本规范书的条款逐条做出详细应答,确认对本规范书要求的满足和差异,对偏差部分应列出偏差表作详细描述。 1.4本规范书所使用的标准如与供方所执行的标准有偏差时,按高标准执行。 1.5本规范书经需供双方确认后作为订货合同的技术附件,与合同正文具有同等的法律效力。 1.6本规范书未尽事宜,由需供双方协商确定。 1.7标准 本规范书提出了最低限度的技术要求,并未规定所有的技术要求和适用的标准,对国家有关的强制性标准,必须满足其要求。 供方在执行本规范书所列标准有矛盾时,按较高标准执 行。

2工程概况(广西电网公司变电站室环境综合整治桂电生【2009】15号文) 2.1铲除主控楼外墙砖后对墙面抹灰及刷乳胶漆 2.2拆除旧楼一栋,平整场地后补种草皮 2.3更换主控室侧门为防火门(注:所更换的门由甲方提供材料、安装,乙方负责修补。) 2.4主控楼排水管更换 2.5主控楼旁排水沟修整 2.6 更换主控室窗帘 3 工程整治要求 3.1主控楼外墙面 主控楼外墙面粘贴釉面全部凿开,全部进行处理为涂料形式。 3.2拆除旧楼一栋,平整场地 拆除在门卫后旧楼一栋,并平整场地。 3.3铺设草皮 在拆除旧楼后的地面铺1公分厚沙子平整场地后种植玉龙草草皮。 3.4主控室侧门

箱式变电站检验规程完整

预装式箱式变电站检验规程 (编号:GL/DY-QES-C51-2015) 宁夏大有电器有限公司 二零一五年 预装式箱式变电站检验规程 专业知识编辑整理 WORD完美格式 1适用范围 本规程适用于本公司生产的预装式箱式变电站出厂检验标准。 2执行标准 GB/7251.1-2013 《低压成套开关设备》 GB/15576- 2008 《低压成套无功功率补偿装置》 GB/17467- 2010 《高压/低压预制式变电站》 3引用标准 GB/10233- 2005 《低压成套开关设备基本调试方法》 GB/3906- 2006 《3.6-40.5KV交流金属封闭开关设备和控制设备》GB/11022- 2011 《高压开关设备和控制设备标准》 GB/700- 2006 《碳素结构钢》 GB/4208- 2008 《外壳防护等级的分类》 《本地供电部门验收规范》 4箱式变电站外形检查 4.1箱体成型后,应符合图纸要求,几何误差见下表。 表1

对角线误差(单位:mm) 前、后面两侧底、顶面 5 3 5 专业知识编辑整理 WORD完美格式 表2 外形尺寸及允许偏差(单位:mm) 外形尺寸允许偏差 变压器容量长宽高长宽高 1000~630KVA 5800~470 630~315KVA 4700~450 2600 0 2200 ±±±315~100KVA 4500~4003.0 5.0 3.0 0 100~50KVA 4000~220 4.2箱式变电站的所有开孔应按图纸要求和《冷加工通用工艺规程》(编号:DY-01-GY)进行并满足箱式变电站自身结构及使用要求。 4.3箱式变电站的骨架应按《焊接通用规程》(编号:DY-02-GY)进行,框架焊接要牢固,不得漏焊,焊缝平整光洁、没有焊穿裂缝、溅渣气孔。 4.3.1吊柱是箱式变电站工艺重点,必须焊接牢固,焊口要有一定深度焊口焊满突出、不得有溅渣,以防在起吊过程中脱落。 专业知识编辑整理 WORD完美格式 4.4箱式变电站的箱体、柜体及其零部件的金属表面的涂覆加工工艺应按《喷涂工艺规程》(编号:DY-03-GY)进行,在柜体和箱体一米处 观察不应有明显的色差和反光。

智能变电站基础知识题库

智能变电站基础知识 一、单项选择题 1. 合并单元是()的关键设备。 (A)站控层;(B)网络层;(C)间隔层;(D)过程层 答案:D 2. 智能终端是()的关键设备。 (A)站控层;(B)网络层;(C)间隔层;(D)过程层 答案:D 3. 从结构上讲,智能变电站可分为站控层设备、间隔层设备、过程层设备、站控层网络和过程层网络,即“三层两网”。()跨两个网络。 (A)站控层设备;(B)间隔层设备;(C)过程层设备;(D)过程层交换机 答案:B 4. 智能变电站中交流电流、交流电压数字量经过()传送至保护和测控装置。 (A)合并单元;(B)智能终端;(C)故障录波装置;(D)电能量采集装置 答案:A 5. 避雷器在线监测内容包括()。 (A)避雷器残压;(B)泄漏电流;(C)动作电流;(D)动作电压 答案:B 6. 智能变电站中()及以上电压等级继电保护系统应遵循双重化配置原则,每套保护系统装置功能独立完备、安全可靠。 (A)35 kV;(B)110kV;(C)220kV;(D)500 kV 答案:C 7. 继电保护设备与本间隔智能终端之间通信应采用()通信方式。 (A)SV点对点;(B)GOOSE点对点;(C)SV网络;(D)GOOSE网络 答案:B 8. 继电保护之间的联闭锁信息、失灵启动等信息宜采用()传输方式。 (A)SV点对点;(B)GOOSE点对点;(C)SV网络;(D)GOOSE网络 答案:D 9. 智能变电站中双重化配置的两套保护的跳闸回路应与两个()分别一一对应。(A)合并单元;(B)智能终端;(C)电子式互感器;(D)过程层交换机 答案:B

10. 智能终端放置在()中。 (A)断路器本体;(B)保护屏;(C)端子箱;(D)智能控制柜 答案:D 二、多项选择题 1. 智能开关的在线监测类型有:() (A)局部放电在线监测;(B)绕组测温在线监测;(C)六氟化硫微水密度在线监测;(D)断路器机械特性在线监测 答案:(A、C、D) 2. 下列哪些设备不属于智能变电站过程层设备?() (A)合并单元;(B)智能终端;(C)线路保护;(D)操作箱 答案:(C、D) 3. 下列哪些设备不属于智能变电站微机保护装置?() (A)交流输入组件;(B)A/D 转换组件;(C)保护逻辑(CPU);(D)人机对话模件 答案:(A、B) 4. 下列哪些不属于智能变电站继电保护装置的硬压板?() (A)“投检修状态”压板;(B)“保护出口跳闸”压板;(C)“投主保护”压板;(D)“启动失灵保护”压板 答案:(B、C、D) 5. 智能变电站的高级应用有:() (A)智能告警及分析决策;(B)顺序控制操作;(C)设备状态可视化;(D)源端维护 答案:(A、B、C、D) 三、填空题 1. 智能变电站定义:采用先进、可靠、集成、低碳、环保的智能设备,以______________、_____________、____________为基本要求,自动完成信息采集、测量、控制、保护、计量和监测等基本功能,并可根据需要支持电网实时自动控制、智能调节、在线分析决策、协同互动等高级功能的变电站。 答案:全站信息数字化、通信平台网络化、信息共享标准化 2. 智能变电站中过程层面向__________,站控层面向运行和继保人员。 答案:一次设备

智能变电站合并单元现状及发展方向探讨 陈乐

智能变电站合并单元现状及发展方向探讨陈乐 发表时间:2017-12-28T21:30:34.337Z 来源:《基层建设》2017年第28期作者:陈乐[导读] 摘要:在我国电力能源领域不断发展的过程中,智能变电站也得到了越来越广泛的应用,本文对合并单元的相关标准进行了详细的介绍,从切换与并且功能、点对点采样模式、时钟同步、独立式合并单元等角度对智能变电站中合并单元的应用技术进行了分析,并阐述了合并单元未来的发展前景。 四川电力送变电建设公司 610000 摘要:在我国电力能源领域不断发展的过程中,智能变电站也得到了越来越广泛的应用,本文对合并单元的相关标准进行了详细的介绍,从切换与并且功能、点对点采样模式、时钟同步、独立式合并单元等角度对智能变电站中合并单元的应用技术进行了分析,并阐述了合并单元未来的发展前景。 关键词:合并单元;智能变电站;发展趋势 自动化变电站系统在世界范围内已经有二十多年的发展历史,随着智能变电站中IEC 61850的普及,分层分布式设计思路与无缝通信设计思想已经占据主流地位,经过数字化改造的过程层信息共享模式在应用方面的技术也越来越成熟。 电子式互感器是智能变电站中十分重要的技术装备,该元件的发展十分迅速,比如在技术上比较成熟的电流互感器,由于该元件以Rogowski空心线圈为基础,原理简单,工程实用化水平高。电子式互感器对于数字化信号有着比较强的兼容性,能够以光纤为媒介,将采样信息输出外界其他设备,电子式互感器的输出接口则需要由面向间隔的电子设备提供,比如合并单元产品。 一、合并单元的标准发展 (一)IEC 60044-8标准 合并单元概念最早出现在电子式电流互感器中,在该标准体系的描述下,合并单元指的是电子互感器二次转换下的电压数据与电流数据进行时间相关组合而形成的物理单元,同时对应用规范层、链路层与物理层进行了详细的规定。铜线与光纤是输出接口的主要介质。传输速率为2.5Mbit/s,采用曼彻斯物编码方式,FT3帧格式传输,通过帧信息可以判断出采集值是否有效并且分析出电压电流采样信息,同时也能够获取设备运行状态信息以及同步数据信息。 另外,电流互感器标准首次提出了秒脉冲同步与插值法两种同步方法,这两种方法也是实现智能变电站应用的基本方法,该方法也也得到了比较广泛的应用与实践。 (二)IEC 61850-9标准 IEC 61850在变电站间隔层与站控层的基础上还定义的过程层概念,过程层指的是一次设备的数字接口。IEC 61850-9同时也对采样信息的通信服务与数字接口进行了详细的规范。其中IEC 60044-8与IEC 61850-9-1之间是向下兼容的关系,在制定标准的过程中,也融入了IEC 60044-8标准下的合并单元概念。在报文格式、同步方式以及精度定义等方面,均与IEC 60044-8相互兼容。 (三)IEC 61869-9标准 IEC 61869-9是IEC60044的替代标准,是针对于仪用互感器而提出的全新标准。相比于传统的IEC60044标准来说,该标准能够对独立式合并单元进行专门的规范,其通信方式不再为FT3,编码方式也不再是曼彻斯特编码,而是对IEC61850-9-2的通信服务方式与信息建模进行了水平引用,并以此为基础,详细规范了测试方法、对外接口、合并单元同步方式等方面的要求。 2.技术应用现状 2.1独立工合并单元 合并单元能将多路数字采集量“合并”在一起,以电子式到感器为载体投入应用。在智能变电站不断发展的过程中,部分旧型呈的变电站需要进行智能化改造,在电子式互感器投入使用的初级阶段,对于常规互感器数字采集功能所提出的要求比较高,进而形成了模拟量采样式的合并单元,能够直接接模拟量信号。常规互感器与模拟量采样式合并单元在形式上完全独立,为了进一步规范合并单元的具体应用技术,需要各行各业均发生了对于模拟量采样式合并单元的有关的标准。

10kV箱式变电站技术规范书

廊坊硕日新能源科技有限公司大城县15兆瓦光伏发电项目 10kV箱式变压器 技术规范书 中国葛洲坝集团电力有限责任公司南京设计院 2016年6月 目录

第一章.总则 (3) 第二章技术规范 (5) 第三章供货范围 (21) 第四章技术资料和交付进度 (24) 第五章交货进度 (26) 第六章监造、检验/试验和性能验收试验 (27) 第七章技术服务和设计联络 (29) 第八章部件供货及外购 (32) 第九章大(部)件情况 (34) 第十章差异表 (35)

第一章. 总则 1.1本规范书适用于廊坊硕日新能源科技有限公司大城县15兆瓦光伏发电项目,采用的 10kV箱式变压器设备,它提出了该设备的功能设计、性能、结构、安装和试验等方面的技术要求。 1.2 本技术规范书提出的是最低限度的技术要求,并未对一切技术细节做出规定,也未充分引述有关标准和规范的条文,卖方应保证提供符合有关工业标准和本技术规范书要求并且是功能完整、性能优良的优质产品及其相应服务。同时必须满足国家有关安全、环保等强制性标准和规范的要求。卖方在设备设计和制造中所涉及的各项规程,规范和标准必须遵循现行最新版本的IEC标准。卖方应提供所使用的标准,本技术规范书所使用的标准如与卖方所执行的标准发生矛盾时,按较高标准执行。 1.3 卖方如对本技术规范书有异议,应以书面形式明确提出,在征得招标人同意后,可对有关条文进行修改。如招标人不同意修改,仍以招标人意见为准。如果卖方没有以书面形式对本技术规范书的条文提出异议,则意味着卖方提出的产品完全符合本规范书的要求。如有异议,不管是多么微小,都必须清楚地表示在“差异表”中。 1.4 卖方必须有权威机构颁发的ISO-9001系列的认证证书或等同的质量保证体系认证证书。卖方(包括分包厂)应设计、制造和提供过同类设备,且使用条件应与本工程相类似,或较规定的条件更严格的高质量的产品,设备应是技术先进并经过同类工程两年以上成功运行,实践证明是成熟可靠的产品及相应的商业运行经验。 1.5本技术规范书提出了对设备本体及其附属设备的技术要求。主要包括设备的使用条件、主要技术参数、结构、性能、试验及所需技术资料等方面的内容;卖方提供的主设备、附件、备品备件、外部油漆等材质必须满足本工程所处地理位置、环境条件的要求。 1.6 1.7 在签定合同之后,买方保留对本技术规范书提出补充要求和修改的权力,卖方应承诺给以配合。如提出修改,具体项目和条件由买、卖双方共同商定。 1.8 中标后卖方应在一周内完成前期的方案设计包括(一次系统图、箱变外形尺寸图、地基图),及时配合生产中图纸设计修改,后期的安装调试、系统调试、试运、验收、运行和维护等标准清单给招标人确认,并承担培训及其它附带服务。 1.9对属于整套设备运行和施工所必要的部件,即合同附件未列出或数目不足,卖方仍

10kV箱式变电站技术规范书

B0143S-X-01 河北滨河房地产开发股份有限公司 10kV箱式变电站 技术规范书 二○○五年九月二十九日 10kV箱式变电站技术规范书 一、总则 1.1 本规范书提出了对该设备的功能设计、结构、安装和试验等方面的技术要求。 1.2 本规范书提出的是最低限度的技术要求,并未对一切技术细节作出规定,也未充分引述有关标准和规范条文。卖方应提供符合规范书和工业标准的优质产品。 1.3 本规范书所使用的标准如与卖方所执行标准不一致时,应按水平较高标准执行。 1.4 本规范书经买卖双方确认后作为合同的技术附件,与合同书正文具有等同法律效力。随合同一起生效。本规范书未尽事宜,双方协商确定。 二、技术要求 2.1 设备制造应满足下列规范和标准:

以下标准所包含的条文,通过在本规范书中引用而构成规范书的条文,其中所示版本为相应最新有效版本。 主要规范和标准如下: 1.IEC56 (1987) 《高压交流断路器》 2.IEC694 (1980) 《高压开关设备标准共用条款》 3.IEC298(198)《额定电压1kV以上50Kv 以下交流金属封闭开关设备和控制设备》 4.ZBK40001-89《组合式变电站》; 5.SD320-89《箱式变电站技术条件》; 6.DL/T537-93《箱式变电站订货技术条件》; 7.GB/17467-1998《高压/低压预装式变电站》 8.GB11022-89《高压开关设备和控制设备的通用条款》 9.GB3309《高压开关设备在常温下的机械试验》 10.GB3804《交流高压负荷开关》 11.GB1985-89《接地开关》 12.GB3906-91《3~35kV交流金属封闭开关设备》 13.GB2706《交流高压电器动、热稳定试验》 14.GB1497《低压电器基本标准》

(完整版)《智能变电站运行管理规范》(最新版)

《智能变电站运行管理规范》(最新版) 为进一步规范电网智能化变电站运行管理工作,保证智能设备安全可靠运行,本规范结合国家电网公司及相关网、省电力公司相关管理标准及现场运行实际,参考各省的《智能变电站运行管理规范》,完成现《智能变电站运行管理规范(最新版)》,供各单位参考和借鉴。 目录 1 总则 2 引用标准 3 术语 4 管理职责 4.1 管理部门职责 4.2 运检单位职责 5 运行管理 5.1 巡视管理 5.2 定期切换、试验制度 5.3 倒闸操作管理 5.4 防误管理 5.5 异常及事故处理 6 设备管理 6.1 设备分界 6.2 验收管理 6.3 缺陷管理 6.4 台账管理 7 智能系统管理 7.1 站端自动化系统 7.2 设备状态监测系统 7.3 智能辅助系统 8 资料管理 8.1 管理要求 8.2 应具备的规程 8.3 应具备的图纸资料 9 培训管理 9.1 管理要求 9.2 培训内容及要求 1 总则 1.1 为规范智能变电站设备生产管理,促进智能变电站运行管理水平的提高,保证智能变电站设备的安全、稳定和可靠运行,特制定本规范。 1.2 本规范依据国家和电力行业的有关法规、规程、制度,智能变电站技术标准、规范等,并结合智能变电站变电运行管理的实际而制定。 1.3 本规范对智能变电站设备的管理职责、运行管理、设备管理、智能系统管理、资料管理和培训管理等六个方面的工作内容提出了规范化要求。 1.4 本规范适用于江苏省电力公司系统内的智能变电站的运行管理。常规变电站中的智能设

备的运行管理参照执行。 1.5 本规范如与上级颁发的规程、制度等相抵触时,按上级有关规定执行。 2 引用标准 Q/GDW 383-2010《智能变电站技术导则》 Q/GDW 393-2010《110(66)kV~220kV 智能变电站设计规范》 Q/GDW394 《330kV~750kV 智能变电站设计规范》 Q/GDW 410-2010《高压设备智能化技术导则》及编制说明 Q/GDW 424-2010《电子式电流互感器技术规范》及编制说明 Q/GDW 425-2010《电子式电压互感器技术规范》及编制说明 Q/GDW 426-2010《智能变电站合并单元技术规范》及编制说明 Q/GDW 427-2010《智能变电站测控单元技术规范》及编制说明 Q/GDW 428-2010《智能变电站智能终端技术规范》及编制说明 Q/GDW 429-2010《智能变电站网络交换机技术规范》及编制说明 Q/GDW 430-2010《智能变电站智能控制柜技术规范》及编制说明 Q/GDW 431-2010《智能变电站自动化系统现场调试导则》及编制说明 Q/GDW 441-2010《智能变电站继电保护技术规范》 Q/GDW580 《智能变电站改造工程验收规范(试行)》 Q/GDWZ414 《变电站智能化改造技术规范》 Q/GDW640 《110(66)千伏变电站智能化改造工程标准化设计规范》 Q/GDW6411 《220kV 千伏变电站智能化改造工程标准化设计规范》 Q/GDW642 《330kV 及以上330~750 千伏变电站智能化改造工程标准化设计规范》 Q/GDW750-2012 《智能变电站运行管理规范》 国家电网安监[2006]904 号《国家电网公司防止电气误操作安全管理规定》 国家电网生[2008]1261 号《无人值守变电站管理规范(试行)》 国家电网科[2009]574 《无人值守变电站及监控中心技术导则》 国家电网安监[2009]664 号国家电网公司《电力安全工作规程(变电部分)》 国家电网生[2006]512 号《变电站运行管理规范》 国家电网生[2008]1256 号《输变电设备在线监测系统管理规范(试行)》 3 术语 3.1 智能变电站 采用先进、可靠、集成、低碳、环保的智能设备,以全站信息数字化、通信平台网络化、信息共享标准化为基本要求,自动完成信息采集、测量、控制、保护、计量和监测等基本功能,并可根据需要支持电网实时自动控制、智能调节、在线分析决策、协同互动等高级功能的变电站。 3.2 智能电子设备 包含一个或多个处理器,可以接收来自外部源的数据,或向外部发送数据,或进行控制的装置,例如:电子多功能仪表、数字保护、控制器等,为具有一个或多个特定环境中特定逻辑接点行为且受制于其接口的装置。 3.3 智能组件 由若干智能电子装置集合组成,承担主设备的测量、控制和监测等基本功能;在满足相关标准要求时,智能组件还可承担相关计量、保护等功能。 可包括测量、控制、状态监测、计量、保护等全部或部分装置。 3.4 智能终端 一种智能组件,与一次设备采用电缆连接,与保护、测控等二次设备采用光纤连接,实现对

相关主题
文本预览
相关文档 最新文档