当前位置:文档之家› 电站小水电增效扩容改造

电站小水电增效扩容改造

电站小水电增效扩容改造
电站小水电增效扩容改造

新化县XXX电站小水电增效扩容改造

实施方案

一、工程概况

新化县XXX电站位于XXX,设计水头58米,引用流量0.15m3/s,设计装机1600KW×1,40KW×1,共2台,装机200KW,设计年发电量45KWh。电站建于1982年,投产至今,设备老化,机组生产力减少,急需进行增效扩容改造,本次小水电增效扩容改造国家投资23.5万元,地方补助11.75万元。

二、合同实施范围

经过水利局对该电站进行技术评估,本次增效扩容改造项目主要是:

1、调整装机容量,更换原有老化机电设备,新增装机35KW,达到235KW,即:160KW×1、75KW×1两台,具体项目内容见附件与电站签订的供货合同。

2、改善电站交通:修一条1公里左右的简易公路至机房。

3、加固引水拦河坝,改造3公里引水渠道进行防渗处理。

4、金属结构:引水坝增加冲砂闸,渠道进水口增加闸门控制,前池拦污栅改造,管理防锈处理。

三、人员组织机构

本项目由我方负责供货和包安装,由我方与电站共同组建项目部对项目实施管理,由我方工程师赵庆荣任项目组长,人员组织如下:

项目经理:XXX,兼技术负责人

专职安全员:XXX

检修员:XXX

四、安全生产管理

本项目由电站法人代表XXX任安全生产领导小组组长,XXX、XXX(专职安全员)为成员,对项目进行安全生产管理。

1、严格执行小水电检修安全生产规范规定要求,分方位提高安全生产意识,认真加强安全生产督查,始终把安全生产放在第一位,切实落实安全生产措施,切断一切安全事故苗头,确保增效扩容改造项目圆满完成。

2、所有进入安装施工程序的人员,均必须持有电力生产特殊工种许可证,非专业人员不得进入安装现场。

3、加强安全生产防护,安装现场悬挂安全生产制度和安全警示标志、标牌。

4、进入施工现场人员均必须戴好安全帽、绝缘胶鞋、防护手套,杜绝无防护进入施工场地现象的发生。

5、严格按操作程序施工,执行工作票制度,严禁无证操作。

6、严禁带电操作。

五、质量管理

以技术负责人为首建立质量管理体系。

设立厂家技术部——项目经理——技术负责人——质检员的质量监管程序。

1、保证设备生产过程中的质量,严格按设备技术要求组织设备生产,并严格通过厂家质检部门的检测检验,每台设备出厂之时同时带有产品合格证和出厂检验证。

2、产品到厂房,由电站监理对产品进行验收、型号、规格,有无出现破损,是否达到合同要求。

3、安装过程做到场地整治,设备堆放有序。

4、严格按程序进行安装,做到轻拿轻放,并保证做到所有安装部序检测数据齐全。

5、电站产品安装做到接线准确,数据真实可靠,。并经过甲方验证认可。、

6、认真做好设备安装完成的调试,72小时甩负荷试验和运行试验。

7、投产前,申请监管方新化县水利局和监理、电站方、供货方的共同检验。

8、提供所有设备质量评定结论。

六、工程付款:

本项目工程付款采取分期付款:即供货合同签订后预付

定金30%,下料生产时(二个月内)再付款30%,提货时付30%,留10%质保金壹年后付清。

七、工期:

自合同签订之日起,2014年8月13日预付定金后5个月内交货,货到后1个月完成安装任务。

我方将以质量第一、安全第一的原则,信守承诺,保质保量完成XXX电站的增效扩容改造项目。

XXXXXXX

XXX年XX月XX日

小水电安全检查

小水电安全检查评估大纲 一、目的 通过检查评估,及时掌握小水电安全生产情况,寻求解决办法及措施,促进小水电安全管理水平提高。 二、主要检查评估工作内容 1、安全生产总体情况(安全生产管理的基本做法、主要特点和管理现状,近年来安全事件管理和发生事故情况,电厂和机组发电能力情况); 2、单位生产运行人员配备情况(人员意识、安全技术技能、队伍稳定情况); 3、安全管理体系建设与责任制落实情况; 4、安全基础管理情况(规程和规章制度、安全生产教育培训、两票三制执行、安全例行工作、危险源分析及应急管理、事故隐患排查、安全设施和劳动保护管理、安全事件信息管理、消防管理等情况); 5、主设备、主体工程相关资质与项目验收情况(制造、设计、施工、调试试验、监理单位资质,工程项目在工程截流、蓄水、机组启动、工程竣工等阶段,质检验收组织健全,资料齐全有效); 6、设备管理情况(设备基础管理、运行、检修和维护等); 7、水库及水工建筑物以及周边环境管理情况、防汛安全情况等。 具体检查评估内容详见《小水电安全检查评估表》。 三、检查评估方法

1、查阅资料。检查评估组成员应通过查阅规章制度、会议记录、文件资料等,全面了解被检查评估单位安全生产管理的基本做法、主要特点和管理现状。 2、现场核查。检查评估组成员通过现场核查,深入了解企业安全管理现状,发现好的做法和存在的问题。还可以通过现场核查,对管理过程进行跟踪,以发现更深层次的问题。 3、访问座谈。检查评估组成员通过访问和座谈,了解被检查评估单位在某一管理领域的某些细节,如管理层的意图能否被员工正确理解,管理思路能否得到正确贯彻,各级各类人员对管理效果的检查评估及改进意见等。检查评估组成员可以自行拟订讨论题开展访问座谈,也可以事先准备好问卷开展现场考问或问卷调查。 三、人员及分工 组长:全面负责本次检查评估工作,重点检查评估安全生产管理的基本做法、主要特点和管理现状,近年来安全事件管理和发生事故情况;单位生产运行人员配备情况;组织编制本次检查评估的总报告 成员:负责检查评估电气设备管理情况,形成本领域分报告 成员:负责检查评估机械设备管理情况;主设备、主体工程相关资质与项目验收情况;电厂和机组发电能力情况,形成本领域分报告 成员:负责检查评估设备运行管理情况;安全生产管理中安全生产责任制及体系建设,安全基础管理情况,形成本领域分报告

平安山一级电站增效扩容改造项目可行性研究报告

1综合说明 1.1绪言 平安山水库位于博罗县柏塘镇白芒洞水,距柏塘镇约8km。水库集雨面积为4.6km2,水库总库容为38.5万m3,正常库容为30万m3。大坝设计洪水标准为:20年一遇洪水设计,200年一遇洪水校核。平安山水库捍卫下游800人民群众的生命安全,保护土地面积350亩,是一座以防洪、供水、发电等综合利用的小(2)型水利工程。 工程等别为Ⅴ等,主要建筑物为5级,次要建筑物为5级。 水库于2011年1月竣工蓄水,主要枢纽建筑物由大坝、开敞式溢洪道、压力输水涵管和平安山一级电站组成,水库下游依次分别建有平安山二级电站(装机?)、平安山三级电站(装机?)。平安山一级电站原装机1台,总容量为100kw,设计年年发电量70.14万kwh。目前由博罗县平安山林场负责管理。 平安山一级电站为坝后式电站,直接由平安山水库大坝坝压力输水涵管引水,本电站始建于1986年8月,于1987年8月投产发电,安装了1台蜗壳式水轮发电机组,水轮机型号为HL260-WJ-50,额定出力为160kw,最大水头33m,额定水头30.8m,最小水头5m,额定流量为0.67m3/S;配套1台型号为TSWN74/36-10的发电机,额定功率160kw,额定电压0.4kv,额定电流288A,额定转速500r/min,额定励磁电压31.3V,额定励磁电流141.5A。经过二十多年的运行,机电设备不断老化,机组的效率逐年下降,在额定工况下,机组出力达不到额定出力。近三年实际平均发电量9.42万kwh,小于设计年发电量70.14万kwh,因下游供水及发电需求增大,从焦木村及狗底窝上游的河道引水至水库,引水集雨面积2.98km2。 平安山一级站运行多年,为缓解博罗县电力供需矛盾,促进工农业生产发展发挥了极其重要的作用。 为贯彻落实《中共中央国务院关于加快水利改革发展的决定》(中发【2011】1号)和《中华人民共和国可再生能源法》精神,提高水能资源利用效率,保障农村用电需要,促进农村水电持续有序发展,中央财政从可再生能源发展专项资金中安排资金,支持开展农村水电增效扩容改造试点工作。 我设计单位受博罗县平安山林场的委托,2013年11月开始实施初步设计工作,2013

二龙山水电站增效扩容改造项目监理规划范本

二龙山水电站增效扩容改造项目 监理规划 编制: 校核: 批准: 陕西江龙工程项目管理有限公司 二 0 一二年四月

目录 第一章:工程概况 第二章:监理工作依据、围、方式及容第三章:监理工作目标 第四章:监理组织机构及人员岗位职责第五章:工程质量控制及措施 第六章:工程进度控制及措施 第七章:工程投资控制及措施 第八章:工程安全控制及措施 第九章:合同管理及其他事项 第十章: 工程信息管理

二龙山水电站增效扩容改造项目 监理规划 一.工程概况 二龙山水库位于长江二级支流的丹江上游,距离商州城西约5公里,水库流域面积956km2,总库容8100万m3,正常库容5700万m3,其中有效库容3800万m3,死库容1900万m3.坝高63.7m,溢流坝顶高程765.0m非溢流坝段高程771.2m校核洪水位770.46m,正常蓄水位765.0m,死水位751m。 该工程主要由大坝、冲沙底孔、引水隧洞、电站、灌溉管涵等组成,为三级建筑物。坝址以上拦截丹江干流及其主要支流板桥河,控制流域面积966km2,为土石山区。坝址处河床宽80m,平均比降8.7%. 拦河大坝为浆砌石重力坝,迎水面现浇混凝土防渗面板,厚1.5-2m。坝高68.7m,坝顶总长153m,其中溢流坝段总长60m,净长57m,坝顶高程765m,底宽55m。非溢流坝段总长92m,左岸长48m,右岸长44m,底宽50m,坝顶高程771.7m,宽7m,上置防浪墙高1.2m。为排沙及便于调节水位,在靠近溢流坝右设泄水底孔,进口高程728.75m,断面2×2.8m,置钢制平板闸门控制,以12.5吨启闭机启闭,最大泄水流量188m3/s。2008年为加大泄洪能力,在坝左岸又开凿一条泄水底孔,断面尺寸,高程与原右岸泄水底孔同。 坝左岸开凿长152m的发电引水隧洞,直径4m,用混凝土初衬,下接钢叉管。引水入坝后水电站,设计安装3×1250kw的水轮发电机组。 主厂房长32m,宽10m,高17.3m。副厂房布置在主厂房上游侧,

文成县小水电安全隐患成因分析及对策

文成县小水电安全隐患成因分析及对策 集团公司文件内部编码:(TTT-UUTT-MMYB-URTTY-ITTLTY-

文成县小水电安全隐患成因分析及对策案例: 文成县水电站有66座,总装机约31万kw,县管电站63座,装机9万kw多,水电站税收占全县的四分之一强。 在转变作风年和调查研究年活动中,我们对全县63座小水电站进行了调查摸底。发现部分水电站在软件、硬件方面都存在较多的安全隐患。具体表现在生产设施老化、失修,接近或超过报废年限仍在运行的机组设备有15座电站,部分机电保护设备不齐或失效,水库大坝、坪水池、渠道漏水;无证上岗人员多,虽经去年、今年三次运行工人培训考核上岗,但这次仍发现有83人无证上岗,其中一些年龄超过60岁,一些人达不到初中文化程度;违章电站多,未批先建或审批手续不齐全即投入发电的电站24座,占38%;部分电站管理混乱,安全生产意识淡簿。 一、成因浅析 小水电站存在的问题较多,有的是历史遗留的,有的是近年来新产生的,究其原因大致有以下方面:

1、职能部门宣传教育、执法力度、部门协作不够及个别人员纵容违法是主要原因。 县府[1996]06号文件出台鼓励开发小水电站后,许多人加入了开发小水电行列,这时主管部门领导调动频繁,县政府分管领导变换很多,职能部门没有很好地宣传引导,使小水电建设进入有序进行,相反地职能部门放松管理,特别是在1998年巨屿镇洪头滩电站未批先建上马,县水利局通知停建无效并建成并网发电后,许多新建或技改增容电站就跟随而来了。电业局、个别水利局和其他部门干部职工参与,明里暗里支持违法违章电站,为违法违章电站推波助澜,有一些违章工程县水利局通知其停建,业主不执行也没有采取进一步的措施。个别管理机关工作人员明知未批先建工程违法,不报告、不检举,反而为赚几个小钱,帮助指导其工程建设,为其提供技术服务,个别设计单位在未办理基本的审批手续,只要付给钱即提供设计图纸,电业部门只要发电就让其并网,没有部门协作把关,致使一些未审批、未验收甚至存在严重安全隐患的电站都能通过关系进入生产。因此,恶性循环也就形成了,有的电站只办理部分审批手续,有的干脆就什么也没批,一些电站没有经水利部门验收即并网发电,建设管理一度形成失控的局面。导致违章电站遗留很多,给安全生产带来隐患,特别是电站水库大坝和压力钢管的安全让人担忧。

电站增效扩容改造工程完工验收鉴定书

湖北省狮子岩电站增效扩容改造工程 项目完工验收 鉴定书 房县狮子岩电站增效扩容改造工程 完工验收委员会

2015年7月 主持单位:湖北省水利厅、财政厅 项目法人:房县农村小水电增效扩容改造项目领导小组设计单位:房县水利水电勘测设计院 监理单位:十堰市大禹水利水电工程建设咨询有限公司主要施工单位:房县万顺园林开发有限公司 主要设备供应单位:河南瑞发水电设备有限责任公司质量监督单位:房水利水电工程质量安全监督管理站运行管理单位:房县狮子岩电站 验收时间:2015年7月 验收地点:房县狮子岩电站

前言 根据水利部《关于印发<农村水电增效扩容改造试点项目验收指导意见>的通知》(水电[2012]329号)和《小型水电站建设工程验收规程》(SL168)的有关规定,2015年7月15 日,由湖北省水利厅、财政厅在狮子岩电站共同主持召开了房县狮子岩电站电站增效扩容改造项目完工验收会议。参加会议单位有:湖北省水利厅、财政厅、十堰市水利电力局、十堰市财政局、房水利水电工程质量安全监督管理站、河南瑞发水电设备有限责任公司、房县水利水电勘测设计院、房县水利电力局、房县农村小水电增效扩容改造项目领导小组、房县狮子岩电站。会议成立了验收委员会,委员会由省水利厅、财政厅、房水利水电工程质量安全监督管理站、房县狮子岩电站等单位的领导和专家组成。 验收委员会委员查看了工程现场,听取了参建各方的工作报告,认真查阅了有关资料,并进行了充分讨论,形成了《房县狮子岩电站电站增效扩容改造项目完工验收鉴定书》。 一、项目设计情况 (一)项目名称及位置 工程名称:房县狮子岩电站增效扩容改造工程

一级水电站增效扩容改造工程初步设计报告

一级水电站增效扩容改造工程初步设计报告

目录 工程特性表 (1) 1 前言 (5) 1.1基本情况 (5) 1.2工程建设过程 (6) 1.3工程现状存在的主要问题 (7) 1.4增效扩容改造初步设计工作开展过程 (7) 2 现状分析及改造必要性评价 (9) 2.1水资源概况 (9) 2.2工程现状及存在的问题 (10) 2.3增效扩容改造的必要性 (16) 3 水文分析 (18) 3.1流域概况 (18) 3.2气象特征 (18) 3.3水文基本资料 (18) 3.4径流 (20) 3.5洪水 (25) 3.6泥沙 (30) 3.7上、下游水位 (31) 4 工程地质 (32) 4.1区域地质概况 (32) 4.2库区工程地质条件 (34) 4.3主体工程地质条件 (35) 4.4副坝工程地质条件 (38)

4.5泄洪洞、发电输水隧洞工程地质条件 (40) 4.6厂区工程地质条件 (40) 4.7天然建筑材料 (41) 4.8结论 (41) 5 工程任务和规模 (43) 5.1地方社会经济发展概况 (43) 5.2工程建设的必要性 (43) 5.3工程任务复核 (44) 5.4工程等级与洪水标准复核 (44) 5.5特征水位复核 (44) 5.6水能计算 (44) 5.7装机容量选择 (53) 5.8装机容量复核 (53) 5.9能量指标及特征水头 (55) 6 改造设计 (56) 6.1设计总体方案 (56) 6.2设计依据 (56) 6.3水工建筑物改造设计 (59) 6.4机电设备改造 (63) 6.5控制设备改造 (82) 6.6金属结构设备改造 (82) 7 消防设计 (83) 7.1消防设计标准与原则 (83) 7.2工程消防设计 (84) 7.3消防给水设计 (85)

当格田一二级水电站增效扩容改造工程施工自检报告DOC

普安县当格田一、二级水电站增效扩容改造35kV线路工程施工管理工作报告 贵州江河水利电力建设工程有限公司 二0一六年十二月

普安县当格田一、二级水电站增效扩容改造35kV线路工程施工管理工作报告 批准: 校核: 编制: 贵州江河水利电力建设工程有限公司 二0一六年十二月

目录 一、工程概况 1、改造前的情况 2、工程建设规模及任务 3、35kV线路改造工程施工设计情况 三、主要施工工艺及完成情况 1、施工工艺 2、工程实施完成情况 三、施工组织及安全管理 1、施工组织机构设置及管理体系 2、施工安全管理 五、施工质量管理 1、施工实施阶段的质量控制主要方法和措施 2、工程的项目划分 3、工程质量评定 六、工程结算 1、合同价款与实际结算价款 2、工程结算价超工程承包价的主要原因 七、自检自评结论 附件:工程施工管理大事记

一、工程概况 1、改造前的情况 由于当格田一、二级水电站建成运行了40多年,当格田一级水电站改造前总容量为1140kw, 当格田二级水电站改造前总容量为总容量为4440kw,电站设备老化严重,问题多多,存在诸多安全隐患,严重地危及到电站的安全运行。为了消除安全隐患,必须对当格田二级水电站进行更新改造,并根据实际情况适当扩容,增加电站的经济效益。特别是当格田二级水电站的35KV联网线路采用LGJ-50导线,电线杆基本上为8~12m的拔稍杆,对地距离低,事故率相对高。对原35KV线路进行改造是很有必要性的。 2、工程建设规模及任务 2012年8月黔西南州水务局,以州水务字【2012】79号文,对《普安县当格田一、二级水电站增效扩容改造工程初步设计报告》进行了批复。当格田一级水电站本次增效扩容装机为2230KW,多年平均发电量将达到804万kw.h,年平均利用小时3605 h。当格田二级水电站本次增效扩容装机为4790KW,多年平均发电量将达到1897万kw.h,年平均利用小时3960 h。 电站至铅矿变35kV线路改造工程是当格田一、二级水电站增效扩容改造项目的建设任务之一。初设阶段选用导线截面为120mm2型号为LGJ-120/20型钢芯铝绞线,进线段地线选配GJ-35型镀锌钢绞线,并按12.8km进行估算投资,估算投资为

文成县小水电安全隐患成因分析及对策(正式版)

文件编号:TP-AR-L5774 In Terms Of Organization Management, It Is Necessary To Form A Certain Guiding And Planning Executable Plan, So As To Help Decision-Makers To Carry Out Better Production And Management From Multiple Perspectives. (示范文本) 编订:_______________ 审核:_______________ 单位:_______________ 文成县小水电安全隐患成因分析及对策(正式版)

文成县小水电安全隐患成因分析及 对策(正式版) 使用注意:该安全管理资料可用在组织/机构/单位管理上,形成一定的具有指导性,规划性的可执行计划,从而实现多角度地帮助决策人员进行更好的生产与管理。材料内容可根据实际情况作相应修改,请在使用时认真阅读。 案例: 文成县水电站有66座,总装机约31万kw,县 管电站63座,装机9万kw多,水电站税收占全县的 四分之一强。 在转变作风年和调查研究年活动中,我们对全县 63座小水电站进行了调查摸底。发现部分水电站在 软件、硬件方面都存在较多的安全隐患。具体表现在 生产设施老化、失修,接近或超过报废年限仍在运行 的机组设备有15座电站,部分机电保护设备不齐或 失效,水库大坝、坪水池、渠道漏水;无证上岗人员

多,虽经去年、今年三次运行工人培训考核上岗,但这次仍发现有83人无证上岗,其中一些年龄超过60岁,一些人达不到初中文化程度;违章电站多,未批先建或审批手续不齐全即投入发电的电站24座,占38%;部分电站管理混乱,安全生产意识淡簿。 一、成因浅析 小水电站存在的问题较多,有的是历史遗留的,有的是近年来新产生的,究其原因大致有以下方面: 1、职能部门宣传教育、执法力度、部门协作不够及个别人员纵容违法是主要原因。 县府[1996]06号文件出台鼓励开发小水电站后,许多人加入了开发小水电行列,这时主管部门领导调动频繁,县政府分管领导变换很多,职能部门没有很好地宣传引导,使小水电建设进入有序进行,相反地职能部门放松管理,特别是在1998年巨屿镇洪

XXX水电站增效扩容改造工程概算

X X X水电站增效扩容改造工 程概算 -标准化文件发布号:(9456-EUATWK-MWUB-WUNN-INNUL-DDQTY-KII

A9湖南省XXX市XXX水力发电站增效扩容改造工程概算 (送审稿) XXX市水利水电勘测设计院 二○一二年六月

项目名称:XXX市XXX水力发电站增效扩容改造工程审定: 审查: 校核: 编写: 设计人员:

目录 1. ··································································································································一 、概算正件......................................................................错误!未定义书签。2. . (1) 、编制说明······································································错误!未定义书签。3. ·································································································································· 工程概况··········································································错误!未定义书签。4. ·································································································································· 主要工程指标··································································错误!未定义书签。5. ·································································································································· 编制原则和依据······························································错误!未定义书签。6. ·································································································································· 定额依据··········································································错误!未定义书签。7. ·································································································································· 编制办法及费用标准 ······················································错误!未定义书签。8. ·································································································································· 其他说明··········································································错误!未定义书签。9. ·································································································································· 基础单价··········································································错误!未定义书签。10.································································································································· 取费 ·················································································错误!未定义书签。11.································································································································· 其他费用··········································································错误!未定义书签。

水电站增效扩容改造初步设计报告

水电站增效扩容改造初步设计报告

目录 1 工程概况 (1) 1.1 工程所在区域自然、社会、经济概况.. 1 1.3 改造方案综述 (2) 2 现状分析及改造必要性评价 (7) 2.1 现状分析 (7) 2.2 增效扩容改造的必要性 (10) 3 水文分析及水能复核 (14) 3.1 水文资料分析在整理 (14) 3.2 水能复核计算 (14) 4 工程地质 (15) 4.1自然地理、地形地貌、区域地质简况 . 15 4.2 工程地质条件及评价 (15) 5 工程任务及规模 (17) 5.1 等级划分及洪水标准 (17) 5.2 复核工程任务 (17) 5.3 特征水位复核 (18) 5.4 装机容量选择 (18) 6 增效扩容改造设计 (19)

6.1 水工建筑物改造 (19) 6.2 机电设备改造 (21) 6.3 金属结构改造 (30) 6.4 送出工程改造 (30) 6.5 其他工程 (30) 7 工程管理 (31) 7.1 工程管理机构 (31) 7.2 运行管理方案 (34) 8 施工组织 (39) 8.1 施工条件 (39) 8.2 施工导流 (40) 8.3 主体工程施工 (40) 8.4 施工总布置 (40) 8.5 施工总进度 (40) 9 工程概算和经济评价 (43) 9.1 工程概算 (43) 9.2 经济评价 (49) 附件一初步设计概算 附件二初步设计图纸

附件三检验测试报告

1 工程概况 1.1 工程所在区域自然、社会、经济概况 1.1.1 自然地理概况 XX地处XX北部,沂沭泗水下游,属鲁南丘陵与江淮平原过渡带。县域介于北纬33°53′至34°25′,东经118°30′至119°10′之间,东西60公里,南北55公里。东与XX接壤,南与淮安市毗邻,西倚XX,北接徐州,是徐、连、淮、宿四市结合部。全县地形呈不规则方形,地势西高东低,大部分地面高程在7-4.5米。县内最高峰韩山海拔70米,除潼阳、茆圩、刘集、悦来等乡镇有些岗岭外,土地平衍,河网密布,有新沂河、淮沭XX等29条河流纵横境内。 XX属于暖温带季风气候,全境气候温和,四季分明,日照充足,雨量丰沛。年平均气温13.8℃,年平均最高气温14.3℃,最低13.3℃。历年最高气温一般在35℃~38℃之间,最低气温在-4℃~-5℃左右。年平均日照时数2363.7小时,年平均相对湿度为75%,年平均风速为2.8米/秒,年平均降水量937.6毫米。 1.1.2 社会经济概况 XX县地处XX北部,隶属地级XX市,辖35个乡镇(场),县域面积2298平方公里,耕地204万亩,人口176万,是全省人口最多、陆域面积最大的县。 XX是中国花木之乡、全国十大商品粮基地县、全国农副产品生产大县、平原绿化先进县,全国著名的蔬菜生产基地、新兴食用菌生产基地、木材加工基地和著名的图书集散中心。。“十一五”末,全县实现地区生产总值288亿元,城镇居民人均可支配收入、农民人均纯收入分别达12900元、6875元。 1.2 工程现状及历年运行情况 1.2.1 工程现状 XX水电站位于XX市XX县XX镇蔷薇河村与XX市XX县XX镇交界,地处沭XX尾,下游为XX河,主要利用灌溉水发电,工程于1986年5月竣工,7月并网发电,减轻地方电网供电压力,另兼顾灌、排水,设计流量为25m3/s。2010年对1#-3#机组拆除更换新机组、2011年4月并网发电。 水电站现装有5台发电机组,1#、2#、3#机组单机装机容量为125kw,发电

小水电生产安全状况分析及对策

小水电生产安全状况分析及对策 发表时间:2018-11-15T16:15:26.650Z 来源:《建筑学研究前沿》2018年第20期作者:黄太平 [导读] 文章分析了当前小水电监管工作面临的主要问题及采取的主要措施,同时提出了破解小水电安全隐患的对策和建议。 湖南省桃源县竹园发电有限责任公司 摘要:小水电站数量多,且农村水电的安全生产工作仍存在薄弱环节,安全生产形势依然严峻。文章分析了当前小水电监管工作面临的主要问题及采取的主要措施,同时提出了破解小水电安全隐患的对策和建议。 关键词:小水电;安全生产;威胁因素;对策建议 1 小水电站的建设与运行现状 在实际检查中,经常出现小水电站运行管理单位安全意识淡薄,只注重经济效益,机电设备年久失修,带病运行等情况。运行管理人员缺乏相关专业技术及安全管理教育,无证上岗,水电站常规维护管理工作无法落实。部分水电站负责人对水电站安全检查工作应付了事,对存在的安全隐患问题漠然处之,出现随意改建、扩建、引水发电现象,致使水电站存在不同程度的安全管理隐患问题。其主要问题主要表现在如下几方面: (1)设备老化,年久失修。大部分小水电站建于上世纪七、八十年代,机电设备已严重老化,引水渠道、压力前池、压力管道年久失修。留下极大安全隐患。个别发电单位在安全与投入上心存侥幸心理,舍不得投资进行技改更新,致使经济效益不高;(2)管理混乱、制度不明确。大部分在运行的水电站管理混乱,机房杂乱无章,制度不明确,缺少最必要的运行管理制度。更有甚者,机房在发电状态下被锁住,无人值班甚至出现机房煮饭、周边空地建鸡舍等情况;(3)缺乏必要的上岗培训。很多运行管理人员存在无证上岗的情况,缺乏必要的技术与安全教育培训;(4)未按审批手续报建。部分发电管理单位未经批准或未经验收合格擅自兴建、改建、扩建发电;(5)安检整改不力。部分发电管理单位对安全检查中出现的安全隐患问题整改不力,不予配合或应付了事。 2小水电现有主要监管措施 2.1 安全检查与隐患整治 小水电能基本实现“三检制”,每月业主“自检”、各级主管单位的“巡检”和“抽检”;编印了《水电工程监督检查登记表》,将电站制度建设落实、安全设施、生产设备设施、作业行为等多项大检查项目分解为若干个小项,并建立起安全检查登记、整改、验收、销号动态机制。通过明确检查标准和工作规范,确保每次安全检查不走形式、见到一定成效。 2.2 安全生产责任制 按属地管理原则,严格落实安全生产责任制和防汛责任制,明确每座电站责任主体、监管责任主体及相关责任人,各责任人签订《小水电安全生产责任书》,对责任人信息进行公示,并在电站现场醒目位置悬挂“双主体”公示牌;各级政府及主管部门与业务股室签订《安全生产责任书》,各监管部门再与下面的业务股室签订责任书;通过指标层层分解,层层落实,形成横向到边,纵向到底,一级抓一级,齐抓共管的良好局面,确保小水电管理全面覆盖,不留监管盲点。 2.3 应急管理基本到位 已出台《小水电站突发事件应急方案》,规范小水电站安全生产应急管理,建立和完善应急值守机制,快速、有效处置小水电突发安全事件。该方案将作为一项长效工作机制,使小水电行业的应急管理工作得到夯实,有利于企业提高风险防范意识,增加保障安全生产的资金投入。 2.4 安全培训已逐步推进 水务、安监、消防等部门举办了多期不同形式的培训班。通过培训“充电”,提高了水电人员队伍的综合素质,增强业主安全生产责任意识,提高广大职工的安全技能。 2.5监管资源得到进一步整合 指导小水电行业协会加强能力建设,健全协会工作制度,引导协会参与行业安全管理、发挥行业自律;水务、安监、供电等职部门加强沟通协调,信息共享,不定期开展联合检查。通过加强监管资源的整合,形成监管合力,提升监管效应。 3 破解农村水电安全隐患的对策和建议 水电事业的不断发展,农村水电安全问题越来越突出,管理方式和运行模式影响着农村水电的安全运行。因此,水电行业主管部门的农电工作重点应从鼓励开发水能资源转移到以安全监管为核心的行业管理上来。现提出以下几种对策和建议供参考。 3.1开展小水电标准化建设,构建准入和退出制度 按照水利部《农村水电站安全生产标准化达标评级实施办法》,尽快开展全县农村小水电安全生产达标评级工作,建立和执行小水电行业市场安全运行准入制和退出制。积极与能源、工商等部门协商,把安全生产标准化等级证作为办理电力业务许可证、工商营业执照等证照的前置条件;对经多次整改不达标或不接受整改的电站、抗拒开展标准化评级的电站,由水行政主管部门强制其退出水电市场。 3.2强化设备管理,提高设备完好率 做好水电站设备管理工作,是保证安全生产的重要手段之一,因此各级监管单位、电站业主要强化设备管理。一要严格按检修规程要求如期进行设备维护、检修工作,发现缺陷及时处理,保证设备安全、可靠。二要严格执行设备评定级鉴定制度,发现隐患及时处理、及时改造、及时更新。三要建立设备管理专责制,对设备管理定岗、定责,责任到人,做到及早发现隐患,及时处理,提高设备完好率。四要加强设备技术改造,彻底消除安全隐患,保障电站安全运行。五要在技术管理上提高小水电站的科技含量,逐步推广应用计算机监控等新技术、新工艺,提高小水电站的自动化和现代化管理水平。 3.3建章立制,严查落实情况 运管单位要建立班长日志、巡检记录、检修记录、不安全事件记录,事故调查报告,安全生产通报、安全会议记录,安全活动记录,安全检查记录档案,并实施有效管理,各主管部门要制订监督检查计划,细化检查方案,组织检查时要细致、全面、准确,杜绝走过场。

浅析小水电站增效扩容改造——以南宁市武鸣区西江水电站增效扩容

浅析小水电站增效扩容改造——以南宁市武鸣区西江水电站增效扩容改造工程为例 发表时间:2017-07-19T16:48:31.387Z 来源:《基层建设》2017年第9期作者:杨琳 [导读] 摘要:为确保小水电站增效扩容改造项目实施的管理,加快水电站改造项目的建设速度,国家对小水电站进行增效扩容方面做了大量的工作,出台了一系列水电站改造资金补助的政策。 南宁市武鸣区西江引水工程管理所广西南宁 530199 摘要:为确保小水电站增效扩容改造项目实施的管理,加快水电站改造项目的建设速度,国家对小水电站进行增效扩容方面做了大量的工作,出台了一系列水电站改造资金补助的政策。这些政策的实施极大地改善了投产早、效率低、技术落后、安全程度低的水电站,并且使得有限的水资源得到了有效的利用与发展,有效的保证了水电发展的需求。本文主要就是根据实践工作经验了解水电站增效扩容改造的相关内容。 关键词:小水电站;增效;扩容;改造 1工程概况 武鸣县西江水电站位于南宁市武鸣县城厢镇共和村,距离武鸣县城11km,电站于1975年12月兴建,1977年3月投入运行,西江水电站是一座坝后式水电站,装有4台立式水轮发电机,机组发电是与大网联网运行,总装机容量为1640kw(2台×320+2台×500),多年平均发电量为661万kW.h,设计年利用小时4020小时,设计水头10m,设计引用流量为21.04 m3/s,本次增效扩容将电站装机容量1640(2×320+2×500)kW增至(2×400+2×650)kW,总装机容量达到2100 kW,多年平均发电量为746.4万kW.h,年利用小时3560小时,多年平均发电量比改造前增加85.4万kW.h,设计水头10m,设计引用流量为25.12m3/s。 2水电站存在的主要问题 2.1设备老化,发电效率降低 武鸣县西江水电站机电设备经过30多年运行电设备功能效率一般,自动化程度很低。机组及其附属和公用辅助设备性能大幅下降、效率低下、水能利用率降低、故障频发。电气设备老化严重,相当一部分自动控制功能已丧失,继电保护的速动性、灵敏性、可靠性明显降低,在很大程度上影响了主设备的安全、稳定运行。另外,由于电站建设投产较早,电站水轮机调速器、发电机励磁系统、各种基础自动化元件、电气设备、监控设备、继电保护设备等受当时制造工艺和技术水平的限制,电站综合自动化水平很低。 2.2水轮机的运行效率较低,参数性能十分落后 武鸣县西江水电站于1975年12月兴建,在技术以及设备方面依然十分落后,特别是对水轮机的水力模型的开发依然处于落后的水平,还依赖于国外的先进技术,早期的水电站所采用的水轮机型号均为苏联或者美国等发达国家所研制的机型,这些机型在某些地方的小型水电站中依然在使用,但是与现代化的技术水平相比,传统的水轮机在转速以及容量方面效率依然很低,而且水轮机的水力稳定性与安全性能较差。 2.3水工建筑物破损失修,安全隐患增多 水工部分建筑物已经比较陈旧,钢门窗锈蚀,木门窗霉烂变形,面层剥离。水轮发电机组、变压器、户外断路器、低压配电设备、电力电缆、监控系统、励磁系统等机电设备已超使用年限,机组出力不能达到额定出力、机电设备老化、运行不稳定、故障率高,自动化程度低等问题,曾出现过一些影响电站正常安全运行的问题和隐患。 3水电站开展增效扩容的必要性 由于明秀水电站现状已影响了安全经济运行和水力资源的充分利用,因此开展小水电站增效扩容改造工程十分有必要。 3.1恢复发电能力 开展农村水电增效扩容改造工程,可在相当大程度上恢复电站生机活力,重新发挥应有的经济效益。电站虽然存在着很多的问题,尤其在设备上,但运行基础条件还在,对主要水轮发电机组设备进行更换,相对来说,以较少的投入达到水电站增效的目的,提高了发电效益。 3.2发挥环境和社会效益 增效扩容改造后,在充分利用清洁能源,解决农村电力供应的同时,对改善农村基础设施和生产生活条件,促进本地农村经济可持续发展以及减少污染物排放等方面发挥了重要作用,得到了本地老百姓的普遍认同。 3.3改善小水电站安全现状 开展小水电站增效扩容改造工程,也有利于改善小水电站的安全现状。小水电站普遍超期服役,主要设备老化、运行不稳定,存在着诸多安全隐患,给小水电站的安全运行和管理带来较大压力。对小水电站的主要设备进行更新改造,彻底消除安全隐患,能大大改善小水电站安全现状,保障小水电站安全运行。 4工程主要任务 本次增效扩容工程主要建设内容为:对厂房内外墙及门窗进行维修更新约1800m2。更换水轮机转轮4台。更新发电机定子、转子线圈4套。更换调速器、励磁装置各4台。新装计算机监控系统1套。更换直流系统2面。更换保护屏、控制屏15面。更换主变压器2台。更换高压屏11面。更换控制电缆3000m;更换电力电缆2100m。 5设计变更情况 5.1一般变更 变更2台主变压器型号。根据变压器生产厂家说明,10kV变压器型号“/”后标的电压等级应为10,且目前国内变压器生产厂家对6300kVA以下户外变压器一般不需增设风扇强制降温,故1#主变压器型号由SF11-1250/11更改为S11-1250/10, 2#主变压器型号由SF11-2000/11更改为S11-2000/10。已由设计单位核定; 取消厂房工程的厂房外墙除料项目,增加厂房屋顶防水工程施工; 取消厂房工程的9扇门,增加厂房大门密封处理; 取消厂房工程的发电机房隔热门及厂区内铺种草皮施工项目,增加厂房厨房窗户封闭处理;取消厂区水泥道路施工项目,增加高压室户外平整硬化;

2021版从俄罗斯水电站爆炸看小水电安全

When the lives of employees or national property are endangered, production activities are stopped to rectify and eliminate dangerous factors. (安全管理) 单位:___________________ 姓名:___________________ 日期:___________________ 2021版从俄罗斯水电站爆炸看小 水电安全

2021版从俄罗斯水电站爆炸看小水电安全导语:生产有了安全保障,才能持续、稳定发展。生产活动中事故层出不穷,生产势必陷于混乱、甚至瘫痪状态。当生产与安全发生矛盾、危及职工生命或国家财产时,生产活动停下来整治、消除危险因素以后,生产形势会变得更好。"安全第一" 的提法,决非把安全摆到生产之上;忽视安全自然是一种错误。 8月中旬,俄罗斯国家最大的水电站发生爆炸,电站机房严重受损,随之而来的水灾造成60多人死亡,据专家估计电站完全修复需要数年。此次爆炸不仅造成了重大的人员和财产损失,而且带来了严重的环境问题,电站水库大坝的后续运行安全更是在下游居民心中形成了挥之不去的阴影。 事故发生后,作为水电站数量非常丰富的中国也应该及时从中吸取教训,对国内水电站安全状况进行认真分析评估,采取积极措施预防相同事故发生。因为别以为水电站发生爆炸的可能性不大,要是一旦发生爆炸,它的后果却是不堪设想的,不但会危及电站工作人员的安全,还会累及水库大坝下游动辄数以万计居民的安全。 据俄罗斯专家初步分析,爆炸是由维修期间的变压器爆炸引起的,变压器爆炸进而引起高压水管爆裂,引发水灾淹没机房并造成大量人员死亡。而世界上其它国家的水电专家分析,似乎变压器爆炸不可能带来如此巨大的威力,但也有的专家认为,变压器爆炸后再引爆高压

XXX水电站增效扩容改造工程概算

A243004369 湖南省XXX市XXX水力发电站增效扩容改造工程概算 (送审稿) XXX市水利水电勘测设计院 二○一二年六月

项目名称:XXX市XXX水力发电站增效扩容改造工程审定: 审查: 校核: 编写: 设计人员:

目录 1.一、概算正件 (3) 2.1、编制说明 (3) 3. 1.1 工程概况 (3) 4. 1.2 主要工程指标 (3) 5. 1.3 编制原则和依据 (4) 6. 1.3.1 定额依据 (4) 7. 1.3.2 编制办法及费用标准 (4) 8. 1.4 其他说明 (4) 9. 1.4.1 基础单价 (4) 10.1.4.2 取费 (6) 11.1.5 其他费用 (8) 12.1.5.1 设备及安装工程 (8) 13.1.5.2 独立费用 (8) 14.1.5.3 预备费及其他 (9) 15.1.6 资金筹措方案 (9) 16.1.7 主要工程指标表 (9) 17.1.8 工程概算总表 (10) 18.2.工程部分概算表 (12) 19.2.1 概算表 (12) 20.(1)总概算表 (12) 21.(2)建筑工程概算表 (13) 1 XXX市水利水电勘测设计院

22.(3)机电设备及安装工程概算表 (14) 23.(4)金属结构设备及安装工程概算表 (15) 24.(5)施工临时工程概算表 (15) 25.(6)独立费用概算表 (16) 26.2.2 概算附表 (17) 27.(1)建筑工程单价汇总表(附表一) (17) 28.(2)安装工程单价汇总表(附表二) (19) 29.(3)主要材料预算价格汇总表(附表三) (20) 30.(4)次要材料价格汇总表(附表四) (21) 31.(5)施工机械台时费汇总表(附表五) (23) 32.(6)主要工程量汇总表 (25) 33.(7)主要材料量汇总表 (26) 34.二、概算附件 (27) 35.1、主要材料预算价格计算表 (27) 36.2、施工用电价格计算表 (28) 37.3、施工用水价格计算表 (28) 38.4、施工用风价格计算表 (28) 39.5、混凝土和砂浆材料单价计算表(附件六) (29) 40.6、施工机械台时费计算表 (30) 41.7、建筑工程单价表 (34) 42.8、安装工程单价表 (44) 2 XXX市水利水电勘测设计院

水电站增效扩容改造施工管理报告

XXXXX 水电站增效扩容改造工程土建施工管理报告

XX水利水电工程有限公司XXXXX 水电站增效扩容改造工程 二O—四年九月 批准: 审核: 编写:

XX水利水电工程有限公司XXXXX 水电站增效扩容改造工程 二O—四年九月 目录 第一章工程概况 (1) 1.1 工程简介. (1) 1.2 参建单位. (3) 第二章施工总布置、总进度和完成的主要工程量 (4) 一、施工总布置 (4) 四、完成主要工程量 (5) 第三章主要施工方法 (7) 一、主要施工参照标准 (7) 第四章施工质量管理 (9) 一、施工组织和质量保证体系 (9) 二、现场质量控制情况 (10) 三、工程施工质量综述 (10) 四、质量事故与质量缺陷 (10) 第五章文明施工与安全生产 (11) 一、安全体系 (11) 二、安全生产责任制 (11) 2、安全管理工作职责 (11) 3、安全技术管理 (12) 第六章结语 (13) 附件1:工程施工管理大事记. (14)

附件2:施工管理机构及主要工作人员 (15) 附件3:质量保证体系机构图. (16)

第一章工程概况 1.1 工程简介 XXX位于福建省中部,戴云山脉西侧;地处北纬25028’ 53〃? 26o09‘ 42〃,东经117028’ 58〃?118o03‘ 13〃;东邻德化,西靠永安,南连永春、漳平,北与三元、沙县、尤溪接壤;东西最宽57公里, 南北最长75公里,总面积2294平方公里,占福建省总面积的1.89%。 本县地形属山区丘陵地带,境内山峦蜿蜒,高峰竣立,沟涧密布。地势大致由西南向东北倾斜,主要地貌形态有中山、低山、高丘、低丘、河谷平原和山间盆谷六大类。山岭、谷地颁有明显的方向性,与境内构造基本一致。海拔千米以上的山峰有99座,最高山峰是南部屏山乡内的大仙峰,海拔1553米,西部的琴山海拔1212米,中部的高峰山海拔1282米,构成了以中、低山为主体的地貌类型。东北部较低,最低点为梅山乡的沧州村,海拔仅210 米,县城海拔350 米。 自然资源十分丰富。矿产资源品种多、储量大,位居福建省前列,是全国首批百个重点产煤县、福建省十大重点矿区和五大重点铁矿区之一,也是福建省水泥生产第二大县。XXX属于中亚热带季风气候,多年平均气温在15.3-19.6 C,多年平均降雨量1492-1810毫米,径流深度为853毫米左右,水能资源较为丰富,汇水面积30 平方公里以上河流24 条,全县水能资源理论蕴藏量为20.76 万千瓦,可开发小水电装机容量为17.6 万千瓦,已开发14.663 万千瓦,占可开发量的83.3%,年发电量已达5亿千瓦时。境内地下水资源总量为3.54 亿吨/年,地热热能资源储藏较丰富, 温泉流量较大,水温高。全县森林覆盖率77%,森林蓄积量637.92 万立方米,县内胜迹景观遍布。

相关主题
文本预览
相关文档 最新文档