5 LC 115 LC 195 S LC 415LC 495 S 绝对式直线光栅尺
- 格式:pdf
- 大小:1.62 MB
- 文档页数:8
LC移相电路在调频和鉴频中的应用与仿真孙冬艳【摘要】由LC回路构成的移相电路具有调节输入输出信号之间的相位关系的作用,在通信电路中有广泛的应用。
为深入研究LC移相电路的应用原理,论文推导了LC移相电路的传递函数,分析相移与电路参数的关系,讨论移相电路在间接调频和正交鉴频电路中的作用。
利用Multisim仿真软件分别对调频和鉴频电路进行了仿真实验并验证理论分析结果,在通信电路课程学习中有助于学生加深对这部分知识的理解和掌握,提高应用能力。
%LC phase shifting circuit can adjust phase shifting between input signal and output signal. It is widely used in communication circuit. In this paper, further research is done on principleof LC phase shifting circuit. Transfer function of LC phase shifting circuit is derived, and the relational expressions between phase shifting and some coefficients are analyzed. Then the applications of LC phase shifting circuit in indirect frequency modulation and quadrature discrimination are discussed, respectively. Multisim software is used for the circuit simulation of frequency modulation and discrimination , and the results of theoretical analysis are verified. It can help the students deepen the understanding of this part of knowledge in the communication circuit course and improve the application abilities.【期刊名称】《电子设计工程》【年(卷),期】2015(000)012【总页数】4页(P145-148)【关键词】移相电路;间接调频;正交鉴频;仿真实验【作者】孙冬艳【作者单位】南开大学电子信息与光学工程学院,天津 300071【正文语种】中文【中图分类】TN702LC回路是通信电路中最常用的无源网络,在电路中具有选频、滤波、移相、阻抗匹配等作用,回路的频率特性及其在通信电路中的应用是通信电路课程教学中的重要内容[1-2]。
LC系列椭圆齿轮流量计OVAL GEAREDFL OWMETER产品使用说明书·铸铁型·铸钢型·铸铁高温型·铸钢高温型·轻型·铸铁高粘度型·铸钢高粘度型·LC—13型·高精度型·不锈钢型·食品不锈钢型·GF、QF、MF脉冲发信器LC系列椭圆齿轮流量计LC—AY40 LC—BH25 LC13—A25LC—AT40 LC—A50 LC12—A40一、概述椭圆齿轮流量计是用于管道中液体流量连续或间断测量和控制的容积式计量仪表。
它具有量程范围大、准确度高、压力损失小、粘度适应性强、能测量高温高粘液体、标定方便、安装建议等诸多优点。
适用于石油、化工、化纤、交通、商贸、食品、医药卫生等部门的流量计量。
LC系列椭圆齿轮流量计LC系列椭圆齿轮流量计装有指针和字轮累积装置,可现场直接显示流经管道内的液体流量和瞬时流量。
在计数机构中附加发讯装置与电显仪表配套可实现累积、定量和瞬时流量远传集中控制。
加装散热器或椭轮欠齿可测量高温、高粘液体。
不同的液体(酸、碱、盐、有机溶液等)流量计主体可选择不同的材质制造。
二、结构与工作原理椭圆齿轮流量计由流量变送器和计数机构组成。
变送器与计数机构之间加装散热器,则构成高温型流量计。
送变器由装有一对椭圆齿轮转子的计量室和密封联轴器组成,计数机构则包含减速机构、调节机构、计数器、发讯器。
计量室内由一对椭圆齿轮与盖板构成初月形空腔作为流量的计量单位。
椭圆齿轮靠流量计进出口压力差推动而旋转,从而不断地将液体经初月形空腔计量后送到出口处,每转流过的液体是初月形空腔的四倍,由密封联轴器将椭圆齿轮转的总数以及旋转的快慢传递给计数机构或发讯器,便可知道通过管道中液体总量和瞬时流量。
*如有特殊需要请另行注明三、性能(误差与压力损失曲线)解释:1 图中各种不同液体可用精度调节装置将流量计误差调整在0轴上下,使误差达最佳值。
班级XX学号机械原理平面机构的构造分析1、如图a所示为一简易冲床的初拟设计方案,设计者的思路是:动力由齿轮1输入,使轴A连续回转;而固装在轴A上的凸轮2与杠杆3组成的凸轮机构将使冲头4上下运动以到达冲压的目的。
试绘出其机构运动简图〔各尺寸由图上量取〕,分析其是否能实现设计意图?并提出修改方案。
解1〕取比例尺l绘制其机构运动简图〔图b〕。
2〕分析其是否能实现设计意图。
图a〕由图b可知,n3,p4,p h1,p0,F0l故:F3n(2ppp)F33(2410)00lh因此,此简单冲床根本不能运动〔即由构件3、4与机架5和运动副B、C、D组成不能运动的刚性桁架〕,故需要增加机构的自由度。
图b〕3〕提出修改方案〔图c〕。
评语任课教师日期1班级XX学号机械原理为了使此机构能运动,应增加机构的自由度〔其方法是:可以在机构的适当位置增加一个活动构件和一个低副,或者用一个高副去代替一个低副,其修改方案很多,图c 给出了其中两种方案〕。
图c1〕图c2〕2、试画出图示平面机构的运动简图,并计算其自由度。
图a〕n3,4解:l图b〕解:n4,5p,p h1,F3n2p l p h1l评语任课教师日期2班级XX学号机械原理3、计算图示平面机构的自由度。
将其中的高副化为低副。
机构中的原动件用圆弧箭头表示。
3-1解3-1:n7,p l10,p h0,F3n2p l p h1,C、E复合铰链。
3-2解3-2:n8,11p,p h1,F3n2p l p h1,局部自由度l评语任课教师日期3班级XX学号机械原理3-3 解3-3:n9,12p,p h2,F3n2p l p h1l4、试计算图示精压机的自由度评语任课教师日期4班级XX学号机械原理n10,p15,p h0解:n11,p l17,p h0解:lp2p l p h3n250331p2p l p h3n210362F0F0F3n(2p l p h p)FF3n(2p l p h p)F310(21501)01311(21702)01〔其中E、D及H均为复合铰链〕〔其中C、F、K均为复合铰链〕5、图示为一内燃机的机构简图,试计算其自由度,并分析组成此机构的根本杆组。
Table 50: DDR3L Differential Output Driver Characteristics V OX(AC)Notes:1.RZQ of 240˖ ±1% with RZQ/7 enabled (default 34˖ driver) and is applicable after prop-er ZQ calibration has been performed at a stable temperature and voltage (V DDQ = V DD ;V SSQ = V SS ).2.See Figure 31 (page 75) for the test load configuration.3.See Figure 30 (page 74) for an example of a differential output signal.4.For a differential slew rate between the list values, the V OX(AC) value may be obtainedby linear interpolation.Figure 30: Differential Output SignalV OHMIN outputMAX outputV OLV OX(AC)maxV OX(AC)minReference Output LoadFigure 31 (page 75) represents the effective reference load of 25ȍ used in defining the relevant device AC timing parameters (except ODT reference timing) as well as the out-put slew rate measurements. It is not intended to be a precise representation of a partic-ular system environment or a depiction of the actual load presented by a production tester. System designers should use IBIS or other simulation tools to correlate the tim-ing reference load to a system environment.Figure 31: Reference Output Load for AC Timing and Output Slew RateV TT = V DDQ /2V SSSlew Rate Definitions for Single-Ended Output SignalsThe single-ended output driver is summarized in Table 48 (page 72). With the reference load for timing measurements, the output slew rate for falling and rising edges is de-fined and measured between V OL(AC) and V OH(AC) for single-ended signals.Table 51: Single-Ended Output Slew Rate Definition4Gb: x4, x8, x16 DDR3L SDRAMOutput Characteristics and Operating Conditionsleast once every 70.3μs. When T C is greater than 85°C, but less the 95°C, the refresh peri-od is 32ms. When T C is greater than 95°C, but less the 105°C, the refresh period is 16ms.37.Although CKE is allowed to be registered LOW after a REFRESH command whent REFPDEN (MIN) is satisfied, there are cases where additional time such as t XPDLL (MIN) is required.38.ODT turn-on time MIN is when the device leaves High-Z and ODT resistance begins toturn on. ODT turn-on time maximum is when the ODT resistance is fully on. The ODT reference load is shown in Figure 24 (page 63). This output load is used for ODT timings (see Figure 31 (page 75)).Designs that were created prior to JEDEC tightening the maxi-mum limit from 9ns to 8.5ns will be allowed to have a 9ns maximum.39.Half-clock output parameters must be derated by the actual t ERR10per and t JITdty wheninput clock jitter is present. This results in each parameter becoming larger. The parame-ters t ADC (MIN) and t AOF (MIN) are each required to be derated by subtracting both t ERR10per (MAX) and t JITdty (MAX). The parameters t ADC (MAX) and t AOF (MAX) are required to be derated by subtracting both t ERR10per (MAX) and t JITdty (MAX).4Gb: x4, x8, x16 DDR3L SDRAMElectrical Characteristics and AC Operating Conditions。
力学性能检验通用规程1.总则:本规程规定了压力容器所用钢材复检、焊接、试板力学性能检验和式样制备的要求,适用于钢材复验试样、产品焊接试板、焊接工艺评定、试板的制作和试样的制取及检2.引用标准:本规程遵循下列标准,新标准公布实施后即以新标准为准。
GB/T228-2002 《金属材料室温拉伸试验方法》GB/T229 《金属夏比(V型缺口)冲击试验方法》GB232 《金属材料弯曲试验方法》GB/T2975 《钢及钢产品力学性能试验取样位置及试样制备》JB4726~4728 《压力容器用钢锻件》JB4744 《钢制压力容器产品焊接试板的力学性能检验》JB4708 《钢制压力容器焊接工艺评定》3.原材料试样:3.1板材试样:3.1.1样坯取样位置、方向及规格:3.1.1.1钢板应在距边缘为板宽四分之一处切取样坯,见图1。
对于纵轧钢板,当产品标准没有规定取样方向时,应在钢板宽度1/4处切取横向样坯,如图2。
如钢板宽度不足,样坯中心可以内移。
切取的样坯应做好标记移植。
3.1.1.2样坯的尺寸要保证从中切取足够数量的试样。
具体尺寸参照表1。
拉力钢板冲击冲击冲击压制弯曲方向图1 图23.1.2试样和试样制备3.1.2.1切取试样时,必须防止试样金属因受热、加工硬化与扭曲变形而改变其内部组织的机械性能。
用气割法切取试样时,从样坯切割线到制成试样边缘,必须留出足够的加工余量,一般不小于20mm。
3.1.2.2钢板厚度小于或等于25mm时,拉力试样应制成板材试样,并保留原轧制表面,试样形式及尺寸见图3,表2。
钢板厚度大于25mm时,可制成尽可能大的圆形试样,试样中心线尽可能接近板面。
此时应尽量使试样头圆弧表面吻合与钢板表面,即在头部应保留不太显著的氧化皮,见图4,表3,表4。
表2 矩形横截面比例试样2、试样原始横截面积So的测定应在试样标距两端及中间三处测量宽度和厚度,取用三处测得的最小横截面积。
测量每个尺寸应准确到±0.5%。
vel an ti de pressant co m pound[J ].Exp Op i n Inve stD rugs ,1997,6(2):65 78 [8] SCHW E I ZER E,W E ISE C ,RICKELS K.P l acebo con trolled tri alof ven l afaxi ne f or t h e treat m ent of m ajor depress i on [J ] J C lin P syc h o pharmacol ,1991,11(16):233 236 [9] M ONT I GNY C ,S I LVERSTONE P H,DEBONNEL G .Ven l afaxinei n treat m en t res i stan t m ajor depression :a C anad i anm u lticenter ,open l abel tri al [J] J C lin P syc h o phar m acol ,1999,19(10):401 406(收稿日期:2010 02 20)基金项目:上海市科委科研计划项目(08411966700)资助作者简介:张梦琪,女,药士 研究方向:临床药学及体内药物分析 *通讯作者:余琛,男,主任药师 研究方向:临床药学 T e:l(021)54031835 E ma i :l chen yu@on li ne s h cn LC M S /M S 同时测定人血清中5种抗精神类药物和9种抗抑郁药物的浓度张梦琪1,贾晶莹1,陆晓佩2,陆川1,曹维锷3,李水军1,刘罡一1,余琛1(1 上海市徐汇区中心医院中心实验室,上海200031;2 上海医药临床研究中心分析化学部,上海200233;3 上海市徐汇区中心医院心内科,上海200031)摘要:目的 建立LC M S /M S 测定人血清中氯氮平、氟哌啶醇、洛沙平、利培酮、泰必利、西酞普兰、氟伏沙明、米安色林、米氮平、吗氯贝胺、帕罗西汀、瑞波西汀、曲唑酮、文拉法辛血药浓度的方法。
超高压液相色谱串联四极杆质谱仪技术指标书1.操作环境工作电压:220V ±10%,单相工作温度:4-35℃相对湿度:小于80%2.液相色谱部分:DGU-20A3/A5在线脱气机真空脱气流路数:3路、5路或者组合使用脱气流速: 3ml/minLC-30AD泵系统:★流速范围:0.0001~5.0000ml/min,0.1ul/min 步进★最高耐受压力: 19000psi流速准确性:±1.0 %★流速精确度:0.06 % RSD柱塞清洗:标配自动清洗组件可压缩性补偿: 自动连续调节,流路独立,可用户自定义梯度设置:0.0-100.0%,最小递增率为0.1%梯度混合精度:±0.1%,不随反压变化SIL-30A 自动进样器:进样体积:0.1~50ul样品容量:115个2.0ml 样品瓶以上★进样量重现性:0.2% RSD以下进样量准确性:±1% 以内★交叉污染: 0.0015 % 以下(标准没有清洗的情况下)样品控温:4-40℃进样速度: 15sec自动样品前处理功能CTO-30A柱温箱:★温度设定范围: 4︒C ~ 150 ︒C控温精度: ±0.05︒C柱容量:两根4.6*150mm以上,可装2个以上柱切换阀柱后冷却器SPD-20A检测器:光源:氘灯,钨灯或氘灯加钨灯波长范围:190-700nm波长准确度:<1nm波长精密度:< 0.1nm噪音:±0.25×10-5飘移:1×10-4AU/h★检测池体积: 2.5ul (可温控)SPD-M20A检测器:光源:氘灯加钨灯波长范围:190-800nm波长准确度:<1nm波长精密度:< 0.1nm噪音:±0.3×10-5飘移:5×10-4AU/h检测池体积:10ul (可更换)同时监测波长个数:16个SPD-M30A光源:氘灯二极管阵列数量:1024个波长范围:190-700nm波长准确度:<1nm波长精密度:< 0.1nm噪音:0.4×10-5飘移:5×10-4AU/h线性范围: 2.5AU检测池体积:1ul (光程长10mm,可更换)★采样频率:200Hz★带检测池控温功能3.质谱部分:基本指标:质量范围:m/z 10-2000★扫描速度:15000 Da/sec (步长0.1u,最大采集速度 150000 data/sec)质量稳定性:不超过0.05amu/24h质量精度:0.1amu分辨率:可调,最高分辨可以达到 0.4 u (FWHM)★动态线性范围:107★交叉污染(串扰): < 0.003%★最小延迟时间:1msec★最小驻留时间:1msec★正负极转换时间:15msecMRM速度:最大500通道/sec灵敏度(ESI):正离子:1pg 利血平, MRM(609->195),S/N ≥1000:1(RMS);离子源:ESI流量范围:0.001-2.000 ml/min (不分流的情况下可以达到)APCI流量范围:0.001-2.000 ml/min (不分流的情况下可以达到)离子化:标准配置加热脱溶剂离子化功能,辅助气体温度可到500℃,有独立的加热模块进行加热,提高离子化效率,适应宽的HPLC流速,提高抗污染能力溶剂耐受:适用于100%有机相到100%水相,能耐用一定浓度的缓冲液复合离子源:同时具有电喷雾源(ESI)和大气压化学源(APCI)的复合电离功能,实现一次进样完成ESI/APCI正负离子的同时检测★DCBI离子源: DCBI离子源释放带电脱溶剂热气体使样品蒸发离子化,可以对固体、液体、组织或聚合物样品等物质进行快速分析。