ProfometerPM-600说明书
- 格式:pdf
- 大小:2.00 MB
- 文档页数:34
Philips 600i seriesAir purifierPurifies rooms up to 21.8 m2Operates at max. 12W170 m³/h clean air rate (CADR)Connected to the Air+ appAC0650/20Our most energy-efficient, compact air purifierCleans the air from allergens and pollutantsWith the push of a button, the air purifier removes allergens and pollutants whileconsuming minimal energy. Its compact, sleek design blends seamlessly into your home.Control the air purifier anytime, anywhere, with the Philips Air+ app.Filtration performance•Removes pollutants in under 17 mins(3)•Filters 99.97% particles as small as 0.003 microns (1)•Removes viruses and aerosols from the air (5)Seamless Operation•Energy-efficient design•Ultra-quiet and no light disturbance•Thoroughly tested for durability and quality you can trustEffortless Control•Control your air purifier with the Philips Air+ app•Compact size and sleek design•Filter lifetime Indicator•3 manual speeds: medium, turbo, sleep modeWhole-room purificationOur air purifier delivers clean air to every corner of the room at a CADR of 170 m3/h, thoroughly purifying rooms up to 21.8m2. Say goodbye to pollutants like PM2.5, bacteria, pollen, dust, pet dander and more in under 17 minutes (3).HEPA filtrationOur 2-layer filtration system featuringNanoProtect HEPA technology captures an impressive 99.97% of ultra-fine particles as small as 0.003 microns (1) NanoProtect HEPA technology not only traps pollutants, but also uses an electrostatic charge to attract them, cleaning up to 2x more air than traditional HEPA H13 filtration, with higher energy efficiency(2).Virus removalVirtually nothing escapes VitaShield expect purer, cleaner air. VitaShield tehcnologycaptures aerosols, germs and particles as smallas 0.003 microns, smaller than the smallest know virus. Tested independently by external lab to remove H1N1 virus from the air. Also tested to remove 99.99% of HCoV-E229 virus (5).Low energy consumptionAchieve cleaner air with minimal energyconsumption and save money on your energy bill. Operating at max. 12W, our purifier is 2x more energy-efficient than other leading air purifiers (7). In sleep mode, it consumes just 2W, 30x less energy than a traditional lightbulb.Ultra-quiet operationEnjoy undisturbed sleep with our innovative purifier. In sleep mode, it operates only at 19 dB (6), quieter than a whisper. Also, the digital display light is dimmed, minimizing any light disturbance. With this setting, the air in your home will be clean always, even at night time.Tested for qualityWhen choosing Philips, you choose Philips for a trusted brand with 80+ years of experience in air care and health tech. Our air purifiers undergo 170 strict inspection tests before release and are certified by the European Centre for Allergy Research Foundation..Connected to Philips Air+ appUse our app for extra convenience andcontrol. In the app, you can turn your purifier on and off, adjust speed settings, and monitor your filter status. Additionally, learn more about air purification through our collection of in-app articles and check outdoor air quality data, available to you anytime, anywhere.Compact size and designOur purifier's compact size and sleek design make it the perfect complement to any space, effortlessly enhancing both the air comfort and aesthetic of your home. At just 34 cm tall, it is perfect to be placed on a desk or shelf. Enjoy fresh and clean air with a touch of sophistication.Issue date 2023-09-28 Version: 7.7.1EAN: 87 20389 02523 5© 2023 Koninklijke Philips N.V.All Rights reserved.Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.Energy efficiency•Max. power consumption: < 12 W•Stand-by power consumption: < 1 W •Voltage: 100-240 VMaintenance•Recommended filter change: 12 months (8)•Replacement filter: FY0611/30•Service: 2-year worldwide guarantee Connectivity•App, connects via Wi-Fi: Air+•Smartphone compatibility: iPhone and Android devicesWeight and dimensions •Dimensions of packaging (LxWxH):263x263x375 mm•Dimensions of product (LxWxH):243x237x341 mm•Product weight: 2.2 kg•Weight incl. packaging: 3.2 kg•Color(s): White, silk beigePerformance•CADR (Particle, GB/T): 170 m³/h•Room size (NRCC): Up to 44 ?•Filtration: HEPA, Pre-filter•Particle filtration: 99.97% at 0.003 microns (1)•Allergens filtration: 99.99% (4)•Virus & aerosol filtration: 99% (5)Usability•Cord length: 1.6 m•Sleep mode•Manual speed settings: 3 (sleep, medium, turbo)•Min. sound level (Sleep mode): 19 dB (6)•Max. sound level (Turbo mode): 49 dB (6)*(1) From the air that passes through the filter, tested with NaClaerosol by iUTA according to DIN71460-1.*(2) Philips air purifiers have higher Clean Air Delivery Rate andenergy efficiency with a NanoProtect HEPA filter than with a HEPAH13 filter, tested to GB/T 18801.*(3) It is a theoretical time for one-time cleaning calculated by dividingits CADR 170 m²/h by the room size of 48 m² (assuming the roomis 20 m² in floor area and 2.4 m in height.*(4) From the air that passes through the filter material, tested withbirch pollen dust on filter media according to SOP 350.003 of theAustrian OFI institute.*(5) Microbial reduction rate test at external lab, with appliancerunning in turbo mode for 1.5 h in a test chamber contaminated withHCoV-229E virus aerosols. While related to it, HCoV-229E isnot SARS-CoV-2, which causes Covid-19.*(6) The average noise level, tested to IEC 60704-1 - 2020, MOD.*(7) Declared CADR per Watt, at max. power, vs. top-20 selling airpurifiers on Amazon Germany, March 2023*(8) The recommended lifespan is calculated based on the averageusage time of the Philips users and the WHO data on the pollutionlevel in the city. Actual life is affected by usage environment andfrequency. Applicable only in countries where the Philips store isavailable.。
BCHP高纯度氧气发生器SPO-600使用说明书北京中惠普分析技术研究所敬告:1. 在使用仪器前请您认真阅读此说明书!2. 切勿在缺电解液的情况下运行!以免造成电解池无法修复的后果。
3. 运输前请务必将电解液倒净,盖好储液桶内盖!以免在运输途中腐蚀机箱及内部元件,造成仪器报废。
注意:1. 需要配合空气源一起使用。
2. 在加电解液时请缓慢将电解液到入储液桶内。
3. 要经常观察电解液水位线,达到下限须立即加入纯净水或二次蒸馏水。
4. 更换完过滤器中的填充物后,务必要将过滤器上盖拧紧以及过滤器和过滤器底座拧紧,以免造成漏气。
企业通过ISO9001:2008质量管理体系认证产品通过国家分析仪器质量监督检验中心检测产品通过国家标准物质检测中心检测产品荣获部级科技进步二等奖产品中国专利号:94222810.3产品在世界银行国际性招标《ITC-943026》项目中标产品被联合国开发计划署《ICEB-Q91211》项目采用目录一、公司介绍 (1)二、产品概述 (1)三、仪器各部位名称 (2)四、仪器的安装与使用 (2)五、主要技术参数 (4)六、仪器的成套性 (4)七、仪器的故障原因与排查方法 (5)八、制造商的保证 (5)九、附图1 气路连接示意图 (5)一、公司介绍北京中惠普分析技术研究所成立于1994年,是一所集科、工、贸于一体的高新技术企业,是国内规模最大的气相色谱仪气源发生器的配套厂家,产品涵盖高纯度氢气、高纯度氮气、低噪声空气源等各种流量单体机及各种相关组合机。
系列全,品种多。
最近又推出供科学研究用超纯氢提纯仪(氢气纯度可达99.99999%)和纯氧发生器、热解析仪等多种产品。
我所于国内首推的小型全自动氢气站更是解决了中心实验室安全集中供氢的难题。
我们坚持质量第一,用户至上的服务准则,产品遍及全国,并出口挪威、阿根廷、韩国、乌克兰等18个国家和地区。
二、产品概述SPO-600型高纯度氧气发生器是通过电解吸附法从空气中获得氧气,其中电解池是利用燃料电池的逆过程设计而成。
BM037BM035BM033BM031Robust Enclosure;Premium Plating & Low Leakage PCBSuperior Immunity To Interference;Reliable Operations And Readings;Meets The Latest EN61326-1 EMC Features Non-Contact (NCV) & Single-Probe Voltage Detection For Identifying Live Lines;Added User Selectable Hi/Lo SensitivitiesDUAL SENSITIVITIES EF-DETECTION PATENTED AmpTip TM CAT III 600V & CAT IV 300V Up To 600V AC Measures Up To 600V DC AmpTip TM REGULAR CURRENT Features 600A Extra-slim Jaws ACA ModelsAnd Hall-effect Jaws ACA/DCA ModelsMAX CONDUCTOR SIZE 26mm, 600Amps Fast Captures In-rush +/- Peak SignalsAt Durations As Short As 5ms;Automatic APO Disable Feature CREST MaxMin IN-RUSH CURRENTS Records Max & Min Readings Over Time;Automatic APO Disable Feature REC MaxMin DISPLAY READINGS REL For Convenient Readings Comparison;DC_Zero For DCA Residue Offset (BM037 & 035)RELATIVE ZERO & DC_ZERO Freezes The DisplayingReading For Later View DATA HOLD Short-Beep Alert On Forward Voltages <0.85V;Beep & Backlight Effects For Shorted DiodesINNOVATIVE BeepLit TM DIODE TEST Best Resolution 0.1Ω At 600Ω Range;2 Auto-ranges Up To 6k Ω (BM035 & 031);5 Auto-ranges Up To 6000k Ω (BM037 & 033)RESISTANCE Quick Open-short Tests On Switches And Wires;Beep & Backlight Effects For Noisy EnvironmentsINNOVATIVE BeepLit TM CONTINUITY For HVAC Flame SensorsTesting Via Test Probes DCµA (BM037 & 033)2 Auto-ranges Up To 2500µFTo Measure Motor Capacitors CAPACITANCE (BM037 & 033)Selectable ºC And ºF Readings;Comes With Bkp60 Bead ProbeTYPE-K TEMPERATURE (BM037 & 033)Up To 6kV 1.2/50µs Lightning Surge;Fully Certified By Independent Test Lab;Years Of Credibility For Serious UsersTRANSIENT PROTECTION Compact AC/DC 600A! Cat-III 600V! AmpTip TM ! Precise Rotary Switch!Compact AC/DC 600A! Cat-III 600V! AmpTip TM ! Precise Rotary Switch!AmpTip TM To Fit, Accurate To Read, Compact To Carry, Safe To Trust, Reliable To Last Body width <50mm For Handy Operations, Overall Length <190mm For Easy CarryingELECTRICAL SPECIFICATIONS Accuracy is ±(% reading digits + number of digits) orotherwise specified, at 23°C ± 5°C.Maximum Crest Factor < 2 : 1 at full scale & < 4 : 1 athalf scale or otherwise specified, and with frequencyspectrum not exceeding the specified frequency bandwidth for non-sinusoidal waveforms.Indication: Bar-graph segments & audible beep tones proportional to the field strength Detection Frequency: 50/60Hz Detection Antenna: Inside the top side of the stationary jaw Probe-Contact EF-Detection: For more precise indication of live wires, such as distinguishing between live and ground connections, use one single probe to test via terminal COM for direct metal Probe-Contact EF-Detection to achieve the most distinctive indication.RANGE 600.0V 1.0% + 5dAccuracyDC VoltageInput Impedance: 10M Ω, 100 pF nominalRANGE AccuracyAC Voltage (with Low-Pass Filter)Open Circuit Voltage: < 3.5VDC typically Short Beep Alert Threshold: Drop across 0.850VBeepLit™ ON Threshold: < 0.100VAudible Indication: Beep soundVisible Indication: LCD Backlighttemperature of the ambient (isothermal stage) for a correct junction voltage compensation. Allow the meter and the type-K probe set to reach isothermal stage for a significant change of ambient temperature. It can take up to an hour for changes > 5°C. 2)Type-K thermocouple range & accuracy notincluded TM conductor: <0.01A/A for BM037 & BM035<0.06A/A for BM033 & BM031TM conductor: <0.01A/A 2)Specified with DC-Zero mode applied to offset the non-zero residual readings, if any 3)Add 5d to the specified accuracy @ < 4A 1.5% + 5d 600.0A conductor: <0.1A/A for BM037 & BM035 <0.6A/A for BM033 & BM031 2)For BM033 & BM031, specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, add 2% to specified accuracy for position errors conductor: <0.1A/A 2)Specified with DC-Zero mode applied to offset the non-zero residual readings, if any 1)DC-bias, if any, not more than 50% of Sine RMS BeepLit™ Continuity Tester:Continuity Threshold: Between 30Ω and 480ΩContinuity ON Response Time: 15ms approx.Audible Indication: Beep soundVisible Indication: LCD BacklightCREST (Peak-Hold): Applicability: Voltage and Non-invasion Current functions Accuracy: Add +/- 250 digits to specified accuracy for changes > 5ms in duration。
Waters 600高精度四元梯度泵中文操作说明书 Waters 600E 控制器前面板Waters 600E 泵液晶显示屏方向键亮度调整键电源开关相对屏幕功能键操作功能键数字键确认键梯度控制器画面一. 操作功能画面说明1.Set up --- 设定泵硬件系统配置选择A,B,C,D 溶剂瓶的氦气法脱气装置开关, 0=关,1=开设定色谱柱加热装置温度上限泵硬件系统配置键压力上下限控制键盘锁定键帮助键2. Direct --- 等度(Isocratic)操作设定FLOW RATE :流动相流速设定( 范围随着硬件规格而定)。
COMPOSITION :流动相设置比例(A+B+C+D=100%)。
CURRENT :当前状态流动相比例。
NEW :改变流动相比例。
SPARGE:氦气脱气装置流量(0~100)。
TEMPERATURE:设定柱温箱温度(室温~9 0℃)。
PRESSURE:显示系统压力值。
SWITCH:外接装置的控制开关。
STOP FLOW:停止泵流速。
3. Operate Method --- 执行梯度功能(GRADIENT)操作设定执行梯度方法代号(#1~15)4. Program Method --- 编辑梯度表(Gradient Table)显示或变更表号清除一行清除表格全部内容存储键5. Program Table --- 编辑事件表(Event Table)显示或变更表号清除一行清除表格全部内容存储键二. 基本操作说明(等度 ISOCRATIC)1. 打开氦气钢瓶,设定输出压力为50~90psi(使用在线脱气机者,请忽略此步骤)。
2. 将溶剂输送塑料管置入储液瓶内流动相中(请注意输送塑料管的代号),打开电源开关至ON(1)的位置,出现如下的开机画面:3. 按一下“Set Up” 功能键,即进入泵设定(Pump Setup )画面。
4. 移动光标设定欲使用的溶剂瓶A,B,C 或D 的氦气法脱气装置开关,使其为“ENABLE” (按“1”, Enter ⇒ ENABLE 打开;按“0”,Enter ⇒ DISABLE 关闭)5. 如果使用柱温箱,设定温度数值(温度上限应低于溶剂沸点)。
HPP-600Pneumatic Hand PumpVolume ControlThe HPP-600pump is equipped with two knobs for fine adjustment of the system pressure.The vent knob can be used to slowly reduce the system pressure.The vent knob should be closed prior to pressurizing the system by turning the knob away from the pump housing.The Vernier knob can be used to increase or decrease the system at a more controlled rate.For fast relieve of the pressure,move the pressure/vacuum pin to the opposite direction.Pressure/Vacuum SelectorThe pump can be used to generate pressure or vacuum depending on the position of the pin located in the pressure/vacuum switch.Press the pin on the side of the pump housing according to labels for the desiredoperation.For High Pressure OperationPrior to pressurizing, back out the Vernier knob until the ring on the Vernier shaft is showing. Pump to pressurize. Turn the Vernier knob towards the pump housing and the pressure should easily be able to reach 600 psi.NOTE:The pump uses a Schrader valve instead of a needle valve.Thus,full open or closed is several turns from the end of the travel.Over-tightening does not increase the seal.FittingsThe pump is equipped with 1/8" and 1/4" BSP ports. In order to use NPT fittings, a NPT to BSP Parallel Thread Adapter is required. These adapters, which are included with the pump, have a bonded washer attached to the male end of the adapter.MAINTENANCENo routine maintenance is required.A periodic check of system calibration is recommended.The Pump is not field serviceable and should be returned to Omega Engineering if repair is needed (field repair should not be attempted and may void warranty).Be sure to include a brief description of the problem plus any relevant application notes.Contact customer service to receive a return goods authorization number before shipping.FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:1.Purchase Order number under which the product was PURCHASED,2.Model and serial number of the product under warranty, and 3.Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:1. Purchase Order number to cover the COST of the repair,2.Model and serial number of the product, and 3.Repair instructions and/or specific problems relative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the lat-est in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.© Copyright 2008 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification;misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted,include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty,negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s)be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.RETURN REQUESTS /INQUIRIES Direct all warranty and rep air requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct, but OMEGA Engineering,Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.。
PROFESSIONAL AIR MOVEROWNER ’S MANUALXPOWER MANUFACTURE, INC. 220 Clary AvenueSan Gabriel, CA 91776, USATel: 626-285-3301, Fax: 626-285-3302 www.xpower.wsPLEASE READ AND SAVE THESE INSTRUCTIONSX-600/ X-600A/ X-630 P-600/ P-630 (115V/230V)X-600 / X-600A / X-630P-600 / P-630IndexIntroduction (2)Operation / Instructions (3)Safety Instructions (4)Maintenance Instructions / Troubleshooting (5)Specifications (6)Warranty / Service (7)Parts List (8)Daisy Chain Specifications / Accessories (9)Warranty Registration Form (10)IntroductionXPOWER Air Movers are ETL/CETL/CE/GS certified and multifunctional Air Mover with the most efficient engineering design. All XPOWER AirFeatures:•Low power draw with a velocity over 2400 CFM when switch on High.•Super quiet and super light weight.•Optional Easy clean filter system.•Easy carrying and storage stackable.•Easily disassembled for thorough cleaning and service.•“Power cord” lengths are 20’/25’ in US and 10’ for Canada•Easy cord wrap on handle•Safety screens on open vents.• 3 speed switch.• 4 air flow positions (0°, 20°, 45°, 90°).0° 20° 45° 90°• Durable and rugged housing with 5 Years Warranty.Operation / InstructionsXPOWER Air Movers are intended to move air and to dry floors, walls, furniture, etc. Durable and easy to operate withan effective balance of static pressure and airflow, the units are suitable for a variety of applications.1. XPOWER Air Movers are shipped ready to be put into service.Prior to plugging the unit into the power source,inspect completely for any shipping damage.2. Plug the electrical cord into the power outlet.3. Carefully place the Air Mover unit on a stable, flat dry surface.4. The unit has four air flow positions, capable to aim airflowacross flat surfaces or angled upward.5. Turn the switch to desired speed and make sure it isoperating correctly.6. All Air Movers in operation must be supervised at all times.AIR MOVER STORAGE:Air Movers can be stacked (up to 4) on their sides for storage.NOTICE:1.Stacking feature is not secure for transportation.2.Remove the filters before stacking.Safety Instructions1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplugthe unit with wet hands or while standing in water.2. To avoid risk of injury, do not direct air flow at face or body.3. To reduce the risk of fire or electric shock, do not use the Air Mover with any solid-state speedcontrol device.4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verificationand / or installation of a GFCI receptacle if necessary.5. Do not operate any Air Mover with a damaged cord or plug. Discard the unit or return it to anauthorized service facility for examination and/or repair.6. Unplug the Air Mover from the power supply before servicing or cleaning.7. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs,runners, or similar coverings. Place the power cord away from traffic area to prevent tripping.8. Do not allow children to play with or around an Air Mover at any time.9. Do not move or carry an Air Mover while unit is operating.10.All Air Movers in operation must be supervised at all times.Maintenance Instructions1. To keep the Air Mover clean, use a damp cloth to wipe the surface of the housing.2. Never clean the Air Mover with water.3.When not in use, unplug and store the Air Mover in a dry indoor place out of reach of children.4. Always disconnect the Air Mover from its power source before performing any maintenance or cleaning.5. Clean the filters (optional item) as often as necessary to avoid loss of airflow.TroubleshootingFor any problems not listed below, call your local distributor or contact our Service Department.SpecificationsXPOWER LIMITED WARRANTYXPOWER Warranty covers the unit from defects in materials and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. The XPOWER Air Mover Housing is covered for a term of fiveyears from the date of original purchase.Important !Warranty does not cover signs of misuse including, but not limited to, a unit that has been dropped, subjected to water damage, tampered with, improper voltage use and unauthorized maintenance and repairs. The POWER CORD and FILTERS are not covered by the warranty.ServiceIn order to receive service or replacement parts under warranty, you must:A. Must Call for a Return Merchandise Authorization (RMA) number through Service Department andobtain ship back instructions.B. Must have original proof of purchase.C. Must use original none damaged packaging or Industrial certified packaging method.The end user will be responsible to ship the unit (with the RMA number showing on the shipping label) to the XPOWER Service Department. Upon inspection, we will advise you of the repairs needed and the cost (if applicable). XPOWER will provide repair or replacement parts depending on warranty.- 7 -600 Series Parts List- 8 -Daisy Chain Specifications (applicable for model X-600A)XPOWER Air Mover Model X-600A is daisy chainable with a low 3.8 amp draw. The 12-amp on-board circuit breaker will allow two (2) additional X-600A units to run on one circuit at the same time.Filters (optional)Note:Air Mover has an on-board circuit breaker. If the auxiliary outlet overloads, the circuit breaker will trip. If the breaker trips, unplug the units and press the circuit breaker reset button.Plug the units back into the power source and turn on the switch.AccessoriesA set of filters is available for the XPOWER Air Mover which will help prevent small debris and dust from entering the Air Mover. To clean the filters: remove filters from the unit and wash with warm soapy water, rinse with clean water and let dry thoroughly before reinstalling.the blower.- 9 -WARRANTY REGISTRA TIONPlease complete and mail or fax for your product warranty. F or a multiple units, please list serial numbers on a separate sheet of paper. Address: XPOWER MANUFACTURE, INC. 220 Clary Avenue San Gabriel, CA 91776, USATel: (626) 285-3301; Fax: (626) 285-3302From:TO:XPOWER MANUFACTURE, INC.220 Clary AvenueSan Gabriel, CA 91776, USATel: (626) 285-3301; Fax: (626) 285-3302。
PM8000 Quick ReferenceKeys -OverviewDevice ON/OFF Long push (2s)Power ON Very Long push (5s)Power OFFMenu Short pushReturn to previous menu level or to measurement screen Home, Measurement Screen Short pushEnter Menu+Home, Measurement ScreenShort push Measure Rebar Diameter Long push (2s)Calibrate MenuShort pushMenu Navigation: rightLeft Side KeyRight Side KeyRight Function KeyLeft Function KeyHome, Measurement Screen Long push (2s)Show pre-set screen(auto-disappear after 2s)Short push Save cover and rebar diametersvalues in spot scan manual modeMenuShort push Menu Navigation: leftHome, Measurement Screen Short push Toggle between 2 statistic views Long push (2s)Start new series with same parameters MenuShort pushConfirm the indicated function and return after 1s to previous menu levelMeasurement screenMeasuring rangeConcrete cover alertNeighboring rebar correctionNumber of measurements takenReference rebar diameter*Measured bar diameter*Measured concrete cover*Calibration alertBluetooth active Battery indicatorMemory fullFurther InformationMetric Units mmASTM Units # units of 1/8 inch Japanese Unitsmm(*) Depending on the unit setting,Start-up and operationDevice needs to be in free space for the complete calibration process(no metal within a 200 mm / 8” sphere)Measurement screen(when no rebar or metal object is detected)Startup ScreenLong push2 secStart DeviceCalibrate DeviceLong pushCalibrateMeasureMeasurement ProcessFind RebarRebar PositionDiameter & CoverShort pushMeasureRebar locatedMove as indicatedNoteRemove all metallic objects such as rings and watches before you start measuring .Main Menu –Overview and NavigationRight Side KeyNavigate RightLeft Side KeyNavigate LeftRight Function KeyChoose indicated functionLeft Function KeyReturn to previous menu level +Home/Measurement ScreenMain Menu ScreenEnter MenuNavigationReference Rebar Diameter Settings Operation Mode SettingsConcrete Cover Alert SettingsNeighboring Rebar Correction SettingsMeasuring Range Audio Settings Units Main Menu –Menu ItemsConfiguration of the operation modeLocate or Spot Scan (data collection)Configuration of the diameter of the reference rebar Configuration of Cover Alert valueConfiguration of spacing between rebars for neighboring rebar correction Configuration of measuring range depending on metal object depthStandard, Deep or AutoConfiguration of all audio signallingRebar centered, Min cover alert or Key pressedConfiguration of measurement unitsIn Metric, ASTM or Japanese UnitsMemory InformationMemory used information / clear Show Device InformationMenu Navigation –Reference rebardiameterMetric unitsASTM unitsJapaneseRight Side ButtonNavigate RightLeft Side ButtonNavigate LeftMain Menu Screen++Further InformationMetric Units mmASTM Units# units of 1/8 inchJapanese Units mmUnitsBefore measuring be sure you set the right units system for your inspectionMenu Navigation –Operation modeFurther InformationLOCATE Rebar location or Metal detection without data storageSPOT SCAN AUTO Automatic data collection of concrete cover when a rebar is detectedSPOT SCAN MANUAL Manual data collection of concrete cover and/or rebar diameter values with Left Side Key buttonRight Side ButtonNavigate RightLeft Side ButtonNavigate LeftMain Menu Screen++Menu Navigation –Minimumcover alertMetric & Japanese unitsASTM unitsRight Side ButtonNavigate RightLeft Side ButtonNavigate LeftMain Menu Screen++If a minimum cover alert is selected,the LED is lit when the cover is below this limit.If audio is on,an audio signal is given.The minimum cover setting is possible with a cover up to 180mm /7.08”.Further InformationMenu Navigation –Neighbouring rebar correctionMetric & Japanese unitsASTM units Right Side Button Navigate Right Left Side Button Navigate LeftMain Menu Screen++It compensates the influence of 1st and 2nd layer neighbor rebars (AI) or 1st layer neighbor rebars only (NRC) on cover measurement of 1st layer rebars. If both a1 and a2 spacings are entered, Φ1 ≤ Φ2 and Standard Range is set, then the Artificial Intelligence is automatically applied. If only a1 spacing is entered or Φ1 > Φ2 or Large/Spot Range is set, then the Neighboring Rebar Correction (only taking into account 1st layer) is automatically applied. The user can enter the spacing value manually or choose the Auto function, which redirects to a Single-Line scan where the spacing is automatically measured and averaged. The rebar size measurement is anyway only corrected with NRC.Further InformationNOTE! This effect can be reduced by the neighboring bar correctionAny ferromagnetic material within the sphere may have an influence on the signal value (e.g. during a reset)Menu Navigation –Measuring rangeFurther InformationSelect between:Mode Rebar or metal object depth Standard < 80mm (Default)Deep from 80mm to 180mm Auto Switches automatically from Standard to Deep Metric & Japanese unitsRight Side Button Navigate RightLeft Side Button Navigate Left Main Menu Screen++The pulse induction principle used by PM8000 has defined operating ranges and accuracies. The measuring range is dependent on the bar size. The expected accuracy of the cover measurement is indicated in the graphic below. (Complies with BS1881 part 204, for a single rebar with sufficient spacing and known diameter).StandardDeepRight Side ButtonNavigate RightLeft Side ButtonNavigate LeftMain Menu Screen++Further InformationSelect/Deselect the sound settings for the following alerts (Default: all off)§Rebar center detected§Minimum Cover alert§Key pressedRight Side Button Navigate RightLeft Side Button Navigate LeftMain Menu Screen++Menu Navigation –MemoryRight Side Button Navigate RightLeft Side Button Navigate LeftMain Menu Screen++Menu Navigation –InfoRight Side Button Navigate RightLeft Side Button Navigate LeftMain Menu Screen+Measurement -AccuracyMeasuring RangeThe pulse induction principle used by PM8000has defined operating ranges andaccuracies.The measuring range is dependent on the bar size.The expectedaccuracy of the cover measurement is indicated in the graphic below.(Complieswith BS1881part204,for a single rebar with sufficient spacing and knowndiameter).DeepStandardStandardDeepMethod 1Map out a rebar grid on a test surface and then select one rebar from the grid that has sufficient spacing from other rebars.Step 1Create a rebar grid by locating rebars.Step 2Select one rebar that has the largestspacing from neighboring rebars.Step 3Use a ruler and confirm that the spacing is larger than the limits of the circle defined above.If not,redo Steps 1and 2until a rebar is located with the required spacing to a neighbor rebar.Step 4Place the center of point of the device of the PM8000over the rebar at themidpoint line of the rebars running crosswise to the rebar under test and click the right side key (short push)for measuring rebar diameter.Midpoint line Measurement –Rebar DiameterFactors Affecting Diameter DeterminationTwo factors affect the determination of the rebar diameter:1.Cover depth.Diameter can be determined for rebars with cover not exceeding 80%of the Standard range.64mm /2.5”.2.Spacing between neighboring bars.For accurate determination of the diameter,the spacing between the rebars must be greater than the limits shown in the drawing below withreference to the center point of the device.Method 2Neighboring rebars that are within the sphere of influence will be detected by the PM8000and will affect cover depth and diameter estimation results.An insufficient spacing is smaller as the minimum spacing defined in Menu Navigation –Neighboring Rebar Correction .The effects of neighboring rebars can be mitigated by keying-in a correction value.NOTE!This works only for rebars of the same layer running in parallel to the rebar under test.Step 1Create a rebar as grid by locating rebars.Step 2Select one rebar that has the largest spacing from neighboring rebars.Step 3Use a ruler to measure the spacing.In case the spacing from the rebar under test to a neighboring rebar is equal or less than 130mm /5.2”go to the main menu,select the icon and input the measured spacing.Verify that neighboring rebar correction symbol is active in the status line at the top of the display as shown in Menu Navigation –Neighboring Rebar Correction .Step 4Place the center of the PM8000over the rebar at the midpoint line of the rebars running crosswise to the rebar under test and click the right side key (short push)for measuring rebar diameter.Diameter Measurement on Areas with sufficient Spacing of the Rebars Diameter Measurement on Areas with insufficient Spacing of the Rebars (Neighboring Rebar Correction)Diameter Measurements on Welded or bound (wires) reinforcement Meshes In most cases a diameter can be measured but the displayed value is far too high and cannot be used.The only way to determine the diameter is by an inspectionhole.For more information on the product use of the product & firmware update with PqUpgrade software please refer to the Product Name PM8000 documentationIt is available for download on For safety and liability information, please download at https:///en/about-us/gtc-and-certificates Subject to change. Copyright © 2022 by Proceq SA, Schwerzenbach. All rights reserved./en/products/profometer-pm8000ASIA-PACIFICProceq Asia Pte Ltd.1 Fusionopolis WayConnexis South Tower #20-02 Singapore 138632T +656382 3966CHINAProceq Trading Shanghai Co., Limited Room 701, 7th Floor, Golden Block 407-1 Yishan Road, Xuhui District 200032 Shanghai | ChinaT +86 21 6317 7479EUROPEProceq AGRingstrasse 28603 SchwerzenbachZurich| SwitzerlandT +41 43 355 38 00UKScreening Eagle UK LimitedBedford i-lab, Stannard WayPriory Business ParkMK44 3RZ BedfordLondon | United KingdomT +44 12 3483 4645MIDDLE EAST AND AFRICAProceq Middle East and AfricaSharjah Airport InternationalFree Zone | P.O.Box: 8365United Arab EmiratesT +971 6 5578505USA, CANADA & CENTRAL AMERICAScreening Eagle USA Inc.14205 N Mopac Expressway Suite 533Austin,TX 78728 | United StatesScreening Eagle USA Inc.117 Corporation DriveAliquippa, PA 15001 | United StatesT +1 724 512 0330SOUTH AMERICAProceq SAO Equipamentosde Mediçao Ltda.Rua Paes Leme136Pinheiros, Sao PauloSP 05424-010 | BrasilT +55 11 3083 3889Version 0.9。
ABBPCM600软件使用方法详解ABB保护逻辑编写和PCM600软件使用方法详解一、概述1、ABB保护逻辑的编写﹡ABB保护逻辑的编写是在电学理论的根底上,通过PCM600调试软件内的逻辑模块的整合,再通过试验验证后,得出的。
﹡PCM600调试软件内的常用逻辑模块列举如下表:功能IEC 61850IEC60617IEC-ANSI 保护三相过电流保护,低定值段PHLPTOC1 PHLPTOC2三相过电流保护,高定值段PHHPTOC1 PHHPTOC2三相过电流保护,瞬时段PHIPTOC1 PHIPTOC2三相方向过电流保护,低定值段DPHLPDOC1 DPHLPDOC2三相方向过电流保护,高定值段DPHHPDOC1接地保护,低定值段EFLPTOC1 EFLPTOC2接地保护,高定值段EFHPTOC1 EFHPTOC2接地保护,瞬时段EFIPTOC1方向接地保护,低定值段〔下一页续表〕DEFLPDEF1方向接地保护,高定值段DEFHPDEF1间歇性接地保段INTRPTEF1接地保护〔越野式双相同时接地故障〕,使用计算的I0EFHPTOC1断相保护PDNSPTOC1负序电流保护NSPTOC1 NSPTOC2 NSPTOC3 NSPTOC4正序欠电压保护PSPTUV1三相欠电压保护PHPTUV1 PHPTUV2 PHPTUV3三相过电压保护PHPTOV1 PHPTOV2 PHPTOV3零序电压保护ROVPTOV1 ROVPTOV2 ROVPTOV3负序过电压保护NSPTOV1手合加速CBRSOF1馈线、电缆和变压器热过负荷保护T1PTTR1便要器的热过负荷保护,两个时间常数T2PTTR1电机的负序电流保护MNSPTOC1 MNSPTOC2负载损失监视LOFLPTUC1电机负荷堵塞保护JAMPTOC1STTPMSU1电机启动监视反相保护PREVPTOCMPTTR1电机的热过负荷保护BSTGGIO1开关量信号传递TR2PTDF1 2W变压器的稳态和瞬动差动保护LNPLDF1线路差动保护和相关的测量,稳态段和瞬动段LREFPNDF1数值稳态低阻抗限制的接地保护高阻抗限制的接地保护HREFPDIF1断路器失灵保护CCBRBRF1涌流检测INRPHAR1主跳闸TRPPTRC1TRPPTRC2弧光保护ARCSARC1ARCSARC2ARCSARC2 控制断路器控制CBXCBR1隔离开关位置指示DCSXSWI1 DCSXSWI2 DCSXSWI3接地开关指示ESSXSWI1紧急启动ESMGAPC1自动重合闸DARREC1分接开关位置指示TPOSSLTC1状态监视断路器状态监视SSCBR1跳闸回路监视TCSSCBR1 TCSSCBR2CT 断线监视CCRDIF1PT 断线监视SEQRFUF1保护信道监视PCSRTPC1电机运行计数器MDSOPT1测量故障录波RDRE1三相电流测量CMMXU1 CMMXU2相序电流测量CSMSQI1 CSMSQI2零序电流测量RESCMMXU1 RESCMMXU2三相电压测量VMMXU1零序电压测量RESVMMXU1相序电压测量VSMSQI1三相功率和电能测量PEMMXU1/MP EMMXU1频率测量FMMXU1逻辑模块的详细解读,请参照ABB技术说明书。