XT-2000i血球分析仪操作维护规程1. 仪器分析原理和分析参数1.1 原理:基于电阻抗检测方法(流体动力学聚焦方法),半导体激光器的流式细胞术方法和SLS血红蛋白检测法。
流体动力学聚焦方法:在检测器中,样品喷头被放在缝隙前,与中心相一致。
稀释样品从样品喷头进入圆锥形腔后,被前鞘试剂包围,穿过缝隙中心,为穿过缝隙中心提供精确的细胞信号。
穿过后,稀释的样品被送入捕捉的试管。
流式细胞术方法:血液样品被吸取、测量、稀释至一定比率并被染色,然后送入流式细胞中心,鞘流机制促进了细胞计数的准确性和重复性。
半导体激光束照射到血细胞,Photodiode接受到前散射光,photo multiplier试管接受后散射光和荧光,光转换为电脉冲,获得血细胞信息。
1.2 分析参数:WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, NEUT%, LYMPH%, MONO%, EO%, BASO%, NEUT#, LYMPH#, MONO#, EO#, BASO#, RDW-SD, RDW-CV, PDW, MPV, P-LCR, RET%, RET#, IRF, LFR, MFR, HFR2. 仪器参数2.1 环境温度:15-30℃;相对湿度:45-85%。
2.2 主机体积:530*630*720mm(宽*高*深);重量:约59kg。
2.3 压缩机体积:280*400*355mm(宽*高*深);重量:约17kg。
2.4 电源供给:主机和进样器:100-240V±10%(50-60HZ)压缩机:100-117V±10%(50-60HZ);220-240V±10%(50-60HZ)2.5 电压:主机和进样器:250VA压缩机:100-117V 50HZ-230VA 60HZ-280VA220-240V 50HZ-220VA 60HZ-250VA 2.6 保护类型:I级设备2.7 绝缘协调:II级电压,2度保护2.8 显示范围WBC 0.00-999.99RBC 0.00-99.99HGB 0.0-30.0HCT 0.0-100.0%PLT 0-9999RET% 0.00-99.99RET# 0.0000-0.99992.9 背景值:WBC 0.1 DIFF-WBC 0.2 RBC 0.02HGB 0.1 PLT 5.0 PLT-0 10 2.10 样本处理速度:约80样本/小时2.11 交叉污染:1.0%以内2.12 样本体积要求:样本模式:150µl;关闭模式:150µl;手动模式:85µl;毛细管模式:40µl。
第四章调整部分4.0 鞘流池的拆解1、松开鞘流单元No.10的锁紧螺丝和锁紧螺帽还有定位螺丝,逆时针选转鞘流调整螺丝可以方便的取下鞘流单元No.10。
2、在下面小心的取下T型接头下面的管道,因为T型接头很容易损坏,取下喷嘴No.9。
3、小心从流式细胞检测部取下鞘流单元No.10。
4、取下鞘流单元的定位螺丝,,并且准备一根1.5 X 6的硅胶管替代No.22部位。
5、更换好No.22管道后,安装No.10底板,黑色的色点朝向激光发光二激光的方向,安装好后,参照上面的图接好管道.1 光学部分(概述)进入菜单-Menu -> Controller -> Service ->LaserPower.打开激光器。
调整针孔调整螺丝使针孔处于激光发光二激光的中央。
取下聚焦透镜的定位螺丝。
4.1.1 激光发光二极管的调整1)通过调整激光发光二极管调整螺丝来使柱面和水平面形成直角。
2)进入菜单-Menu -> Controller -> Service ->Laser Power.打开激光器。
用内六方扳手放在激光发光二极管和鞘流池之间,像下图那样,如果角度正确,激光发光二极管的光速和鞘流池反射的光束在内六方扳手上形成一条直线。
如果不是这样,松开鞘流单元No.10的定位螺丝,进行鞘流角度调整后,交替拧紧定位螺丝,在LASER POWER屏幕上按OK关闭激光器。
4.1.2 安装聚焦透镜No.61) 调整聚焦透镜No.6的位置松开定位螺丝,调整聚焦透镜的调整螺丝使透镜仓No.39的边缘和反射管No.14的边缘之间有2-3毫米的间隙。
安装好聚焦透镜No.6的定位销钉临时拧紧定位螺丝。
2)进入菜单-Menu -> Controller -> Service ->Laser Power.打开激光器。
3)松开鞘流调整螺丝的紧固螺帽并松开鞘流紧固螺丝。
4)逆时针调整鞘流调整螺丝使激光束穿过鞘流池。
CTT2000L/M专用数字通信系统操作台手册中国计算机软件与技术服务总公司电话:市电(010) 62174278 , 62173406路电(021) 49580 , 74666,1 CTT-2000L/M 调度台 (4)2 调度台硬件结构介绍 (4)2.1 键盘调度台板面介绍 (4)2.2 键盘调度台侧面介绍 (6)2.3 键盘调度台内部结构介绍 (6)3 调度台操作说明 (7)3.1 启动或关闭系统 (7)3.2 系统运行主屏幕 (7)3.2.1 菜单操作预说明 (8)3.2.2 进入运行 (8)3.2.3 调节音量 (9)3.2.4 调节亮度 (10)3.2.5 查看数据 (10)3.2.5.1 退出 (11)3.2.5.2 未接电话 (11)3.2.5.3 通话记录 (11)3.2.5.4 系统数据 (12)3.2.5.5 清未接电话 (12)3.2.5.6 清理全部记录 (13)3.2.6 播放录音 (13)3.2.6.1 顺序播放录音 (14)3.2.6.2 选择播放录音 (14)3.2.7 设置数据 (15)3.2.7.1 退出 (16)3.2.7.2 修改单呼键 (16)3.2.7.3 修改组呼键 (17)3.2.7.4 增加单呼键 (18)3.2.7.5 增加组呼键 (19)3.2.7.6 删除呼叫键 (19)3.2.7.7 修改口令 (20)3.2.8 设置数据 (21)3.2.8.1 退出设置系统 (21)3.2.8.2 调度台请求加载数据 (21)3.2.8.3 调度台数据初始化 (22)3.2.9 测试系统 (22)3.2.9.1 0.退出设置系统 (23)3.2.9.2 1. LED灯测试 (23)3.2.9.3 2. 键盘测试 (23)3.2.9.4 3. U接口环回测试 (24)3.2.9.5 4. 数据FLASH测试 (24)3.2.9.6 5. 录音FLASH测试 (25)3.2.9.7 6. 系统复位 (25)3.3 功能键说明(12个) (25)3.3.1 自动 (25)3.3.2 键权 (25)3.3.3 转移 (26)3.3.4 强制 (26)3.3.5 录音 (26)3.3.6 放音 (26)3.3.7 主辅 (26)3.3.8 保留 (26)3.3.9 会议 (27)3.3.10 全呼 (27)3.3.11 挂机 (27)3.3.12 应答 (27)3.4 系统基本工作 (28)4 附录 (29)1CTT-2000L/M 调度台调度台是调度员进行调度指挥的操作平台,调度员通过调度台上的各种按键进行各种调度操作,如应答来话、转移或保持来话、呼叫用户、召集会议等。
维修手册CT-C2000产品沈阳东软数字医疗系统股份有限公司客服中心CT-C2000故障手册目录第一章高压系统原理简介&2第二章常见故障分析与处理&21附录激光相机常见故障及处理方法&34 附A 柯达160相机常见故障及处理方法&35 附B 柯达8100相机常见故障及处理方法&41 附 C 969相机日常维护及常见故障处理方法&45第一章高压工作原理1.0概述:在此30KW供给中有四个电源,四个电源中的三个变压器被用来给X射线管提供电力,射线电源可以提供高达150KV的电压,这个电压加在球管的阳极和阴极之间(以地作参考电压,电压值分别为正负75KV),灯丝电源可对每个球管灯丝提供高达5.5A的电流,转子电源提供一个频率为60HZ,电压值呈阶梯型变化的电压给球管转子,既先产生240V的电压并持续1.5秒,然后变为100V直到曝光结束。
辅助电源用来向内部电路供电。
这个电源提供稳压后的正负12V电压给逻辑电路,和未经稳压的正负35V电压作为灯丝和SCR的驱动电源。
1.1线电压连接参考图727137(系统原理图)。
线电压被连接到装配于后面板的保险丝部件,交流线电压通过驱动/辅助板端子E12和E13,来给辅助变压器(T1)和软启动电路供电。
这个交流电压经过交流接触器馈给由D1——D5组成的整流电桥,整流后的正负两根电压线加到C7和C2上。
位于机壳装配架底部的一些电容器,为射线电源提供滤波和大量储备,分压电阻R4和R5在关闭该装置后的五分钟内对储能电容器放电。
1.2射线电源工作原理射线电源从大量储能电容器得到它所需的动力,射线电源利用一个工作在连续和不连续模式下的半桥串联谐振逆变装置。
扼流圈L5和L6, 若干电容器, 高压系统由主变压器初级电感和谐振电感L3和SCR组成, 其中SCR的驱动由驱动/辅助驱动板上的连接器J5和J6实现。
详见系统原理图案727137。
CTT2000L/M专用数字通信系统用户手册(维护分册)中软网络技术股份有限公司路电:021-66002~66005市电:010-~传真:021-66001目录第一章 CTT2000L/M系统简介.......................... 错误!未定义书签。
系统特点...................................... 错误!未定义书签。
处理能力及可靠性........................... 错误!未定义书签。
接口丰富,组网能力强....................... 错误!未定义书签。
完善的测试和告警功能....................... 错误!未定义书签。
系统可维护性好............................. 错误!未定义书签。
系统功能...................................... 错误!未定义书签。
接入铁路各项专用业务....................... 错误!未定义书签。
调度功能................................... 错误!未定义书签。
调度电话的组网方式......................... 错误!未定义书签。
通道保护功能............................... 错误!未定义书签。
集中管理维护功能........................... 错误!未定义书签。
用户交换机功能............................. 错误!未定义书签。
会议汇接机功能............................. 错误!未定义书签。
录音功能................................... 错误!未定义书签。
第二章系统组成.................................... 错误!未定义书签。
CTT2000L/M专用数字通信系统操作台手册中国计算机软件与技术服务总公司电话:市电(010) 62174278 , 62173406路电(021) 49580 , 74666,1 CTT-2000L/M 调度台 (4)2 调度台硬件结构介绍 (4)2.1 键盘调度台板面介绍 (4)2.2 键盘调度台侧面介绍 (6)2.3 键盘调度台内部结构介绍 (6)3 调度台操作说明 (7)3.1 启动或关闭系统 (7)3.2 系统运行主屏幕 (7)3.2.1 菜单操作预说明 (8)3.2.2 进入运行 (8)3.2.3 调节音量 (9)3.2.4 调节亮度 (10)3.2.5 查看数据 (10)3.2.5.1 退出 (11)3.2.5.2 未接电话 (11)3.2.5.3 通话记录 (11)3.2.5.4 系统数据 (12)3.2.5.5 清未接电话 (12)3.2.5.6 清理全部记录 (13)3.2.6 播放录音 (13)3.2.6.1 顺序播放录音 (14)3.2.6.2 选择播放录音 (14)3.2.7 设置数据 (15)3.2.7.1 退出 (16)3.2.7.2 修改单呼键 (16)3.2.7.3 修改组呼键 (17)3.2.7.4 增加单呼键 (18)3.2.7.5 增加组呼键 (19)3.2.7.6 删除呼叫键 (19)3.2.7.7 修改口令 (20)3.2.8 设置数据 (21)3.2.8.1 退出设置系统 (21)3.2.8.2 调度台请求加载数据 (21)3.2.8.3 调度台数据初始化 (22)3.2.9 测试系统 (22)3.2.9.1 0.退出设置系统 (23)3.2.9.2 1. LED灯测试 (23)3.2.9.3 2. 键盘测试 (23)3.2.9.4 3. U接口环回测试 (24)3.2.9.5 4. 数据FLASH测试 (24)3.2.9.6 5. 录音FLASH测试 (25)3.2.9.7 6. 系统复位 (25)3.3 功能键说明(12个) (25)3.3.1 自动 (25)3.3.2 键权 (25)3.3.3 转移 (26)3.3.4 强制 (26)3.3.5 录音 (26)3.3.6 放音 (26)3.3.7 主辅 (26)3.3.8 保留 (26)3.3.9 会议 (27)3.3.10 全呼 (27)3.3.11 挂机 (27)3.3.12 应答 (27)3.4 系统基本工作 (28)4 附录 (29)1CTT-2000L/M 调度台调度台是调度员进行调度指挥的操作平台,调度员通过调度台上的各种按键进行各种调度操作,如应答来话、转移或保持来话、呼叫用户、召集会议等。
wordCTT2000L/M专用数字通信系统用户手册〔维护分册〕中软网络技术股份路电:021-66002~66005市电:010-51866002~51866005:021-66001目录第一章 CTT2000L/M系统简介31.1 系统特点31.1.1 处理能力与可靠性31.1.3 接口丰富,组网能力强31.1.4 完善的测试和告警功能41.1.5 系统可维护性好41.2 系统功能51.2.1 接入铁路各项专用业务51.2.2 调度功能61.2.3 调度的组网方式61.2.4 通道保护功能61.2.5 集中管理维护功能81.2.6 用户交换机功能91.2.7 会议汇接机功能91.2.8 录音功能9第二章系统组成102.1 后台主机102.2 操作台(前台)152.3 集中维护管理终端162.4 录音系统172.4.1 数字集中录音系统172.4.2 键控操作台录音系统172.5 主要性能指标192.5.1 结构尺寸〔单位mm〕192.5.2 工作电源192.5.3 环境要求212.5.4 接口指标21第三章系统的安装与配置24、机柜的安装24、机架的安装24、子框的安装24、外线的连接25、电源线配置与连接25、接口外线配置与连接26、2M线配置与连接30、RS232串行通信口的连接31 、单板的配置33、线路板的插接34、单板的开关调整34、模块跳线说明36、单板状态指示与调整37、单板状态指示37、单板按键说明40、背板开关的调整40、操作台的安装与配置40第四章常见问题与须知事项41、调度台故障41、模拟用户故障42、其它须知事项43附录一: 音选分机呼叫频率对应表44第一章CTT2000L/M系统简介1.1 系统特点1.1.1 处理能力与可靠性●模块化设计,分布式集中控制方式,使系统具有很高的稳定性、可靠性和很强的话务处理能力,保证铁路专用通信畅通无阻。
●各级CPU均采用MOTOROLA 32位高性能处理器,处理能力强,系统允许一个数字环上挂接的车站多达64个。
仪器维护手册一、仪器简介本仪器是一款高性能的检测设备,主要用于各种实验和检测工作。
它采用了先进的技术和精良的工艺制作而成,具有高精度、高稳定性、易操作等特点。
本仪器可以大大提高实验和检测工作的效率和准确性,是科研和生产领域中不可或缺的重要工具。
二、操作规程1.在使用仪器之前,请仔细阅读本手册,并确保您已经了解了所有的操作步骤和注意事项。
2.确保电源电压与仪器要求相符,避免过载或欠压。
3.在使用过程中,请勿随意拆卸、改装或修理仪器,以免造成损坏或安全事故。
4.对于不熟悉的操作,请先咨询专业人员或厂家技术支持。
5.在使用过程中,请注意保持仪器的清洁和干燥,避免水、尘等杂质的侵入。
三、日常维护1.每天使用完仪器后,应关闭电源,并用干净的布擦拭仪器表面,保持清洁。
2.对于仪器的各个部件,应定期检查是否有松动、损坏或老化现象,及时处理或更换。
3.确保仪器的工作环境良好,避免强光、高温、潮湿等不良环境因素对仪器的影响。
四、定期检查1.定期检查仪器的各个部件是否正常工作,如发现异常应及时处理或联系厂家维修。
2.定期对仪器的性能进行检测,以确保其精度和稳定性符合要求。
3.定期清理仪器内部的灰尘和杂物,以保证其正常运行。
五、故障排除1.如仪器出现故障,应先查明原因,不要随意拆卸或修理。
2.对于常见故障,可以参考本手册进行排除;对于复杂故障,应联系专业人员或厂家技术支持进行处理。
3.在排除故障时,应注意安全,避免造成更大的损失或安全事故。
六、维修保养1.仪器的维修保养应由专业人员进行,不要自行进行拆卸或修理。
2.在维修保养时,应注意更换损坏或老化的部件,以保证仪器的性能和使用寿命。
3.在维修保养后,应进行全面的检测和调试,确保仪器的工作状态正常。
I © Copyright Eurotherm Automation 1995All rights reserved. All reproduction or transmission in any form or using any procedure (electronic or mechanical, including photocopying and recording) without the written permission of EUROTHERM AUTOMATION is strictly prohibited. EUROTHERM AUTOMATION have taken particular care to ensure the accuracy of these specifications. However, in order to maintain our technological lead, we are dedicated to the continual improvement of our products and this may lead to modifications or omissions in the current specifications. We cannot be held responsible for any material or bodily damage, losses or costs incurred.Part No HA 174757 ENG Issue 1 Printed in France 10/96Thyristor power units and Solid state contactorsTC2000seriesTwo-phase control of a three-phase load or control of two single-phase loadsUser Manual晶闸管动力单元和固态接触器三相负载的二相控制或两个单相负载的控制用户手册II EUROPEAN DIRECTIVESTC2000 User ManualThe TC2000 products installed and used in accordance with this User Manual are designed to comply with the essential protection requirements of the European Low Voltage Directive 73/23/EEC dated 19/02/73 (amended by Directive 93/68/EEC dated 22/07/93).The TC2000 products are considered as components without any direct function as defined in the EMC Directive. The system or installation in which these products are incorporated must complies with the essential protection requirements of the EMC Directive.However, Eurotherm certifies that the TC2000 products, when installed and used in accordance with their User Manual, meets the following EMC test standards and enables the system or installation in which there are installed to comply with the EMC Directive in regards to the TC2000 products.ELECTROMAGNETIC COMPATIBILITY (EMC)For industrial environments, excluding residential environmentsA CE Declaration of Conformity is available on request.For further information on CE Mark, please contact your nearest Eurotherm office.The CE Mark of TC2000 products implies that the essential protection requirements of the European Low Voltage Directive are observed.The TC2000 Technical Construction File is approved by a Notified Body, LCIE(Laboratoire Central des Industries ƒlectriques).SAFETY 欧洲指令安全电磁兼容性按照本用户手册中安装和使用的TC2000产品,设计符合欧洲低电压规范73/23/EEC必要的保护要求,日期:19/02/73(修订指令93/68/EEC日期22/07/93)IIITC2000 User Manual EMC STANDARDSTo reduce the conducted emissions that occur when using thyristor units, the EMC internal filter is added (standard for 60 A and 75 A; optional for 100 A and 150 A).EMC FILTERImmunityGeneric Standard :EN 50082-2Test Standards :EN 61000-4-2,EN 61000-4-4,ENV 50140,ENV 50141Emissions Generic Standard :EN 50081-2Test Standard :EN 55011Product Standard :IEC1800-3The choice of the Conducted Emission applicable standard depends on the application¥ EN 50081-2 :With a internal standard filter for 60 A and 75 A nominalWith a internal optional filter (FILT option) for 100 A and 150 A nominal ¥ IEC 1800-3 :Without filter. Applies for the second environment.EMC INSTALLATION GUIDEIn order to help you reduce risks related to the effects of electromagneticinterference depending on the installation of the product, Eurotherm can supply you with the "EMC Installation Guide " (Part No. HA025464).This guide gives the rules generally applicable for Electromagnetic compatibility.VALIDATION BY COMPETENT BODYIn order to guarantee the best service, Eurotherm has validated the compliance of the TC2000 products with EMC test standards through design and laboratory tests that have been validated with a Technical Construction File by a Competent Body, LCIE (Laboratoire Central des Industries ƒlectriques).IV TC2000 User ManualTC2000 User Manual C o n t .1ContentsTC2000 USER MANUALChapter 1 IDENTIFYING THE UNIT General introduction to the TC2000 series ..................................1-2Technical data..............................................................................1-7Coding........................................................................................1-10Serial number labels ................................................................. 1-12PageChapter 2 INSTALLATIONSafety during installation..............................................................2-2Dimensions ..................................................................................2-3Mechanical mounting ...................................................................2-5Installation details.........................................................................2-6Chapter 3 CABLINGSafety during cabling....................................................................3-2Fixing power cables .....................................................................3-3Power wiring diagrams.................................................................3-6Auxiliary power supply .................................................................3-9Control cables ............................................................................3-10Driver terminal block ..................................................................3-12Input signal connection ..............................................................3-13PLU alarm signalling (optional)..................................................3-17Chapter 4 CONFIGURATIONSafety during configuration ...........................................................4-2Possible configurations .................................................................4-3Operation type ..............................................................................4-4Configuration type........................................................................4-6Input type and level.......................................................................4-7PLU board (optional).....................................................................4-9目录第一章 认识这个单元Cont.2 TC2000 User ManualContents (Continued)Chapter 5 OPERATIONChapter 6 COMMISSIONING PROCEDUREThyristor firing mode .................................................................5-2PLU detection ...........................................................................5-6Commissioning procedure safety..............................................6-2Checking the characteristics .....................................................6-3PLU detection adjustment (optional).........................................6-5PageChapter 7 MAINTENANCEThyristor protection ...............................................................................7-2Thyristor protection fuses......................................................................7-3Fuse blown indication micro-switch ......................................................7-5Protection fuses for auxiliary power supply connection ........................7-6Servicing ...............................................................................................7-7Tools .....................................................................................................7-8Configuration recapitulatory tables .......................................................7-9INDEXIdentificationChapter 1IDENTIFYING THE UNITContents pageGeneral introduction to the TC2000 series...................1-2Technical data...............................................................1-7Coding.........................................................................1-10Serial number labels.................................................. 1-12TC2000 User Manual 1-1IdentificationChapter 1 IDENTIFYING THE UNITGENERAL INTRODUCTION TO THE TC2000 SERIESThe TC2000 thyristor unit series is designed for the electrical power control of industrialthree-phase or single-phase loads.Depending on the type of operation, the TC2000 series is composed of two types of unit:• Solid state contactors (logic operation).Units driven by a logic signal, operating in ON/OFF mode, emitting themaximum power to the load during the presence of the control signal.• Power thyristor units (analogue operation).Units driven by an analogue signal emitting an output power proportional tothe input signal for thyristor firing and in Burst firing mode including a wholenumber of alternations.For the solid state contactors and the power thyristor units, the thyristor firing and non-firing are synchronised at zero voltage for each phase, eliminating the steep current fronts whichgenerate supply interference.TC2000 series units are composed of two thyristor channels, which allows the following two types of configuration:• three-phase configuration• single-phase configuration.In the three-phase configuration, the T C2000 series units control two phases of a three-phase load connected in a closed delta or a star without neutral (3-wire configuration).In this configuration, only one control signal is used.In the single-phase configuration, the TC2000 series units behave in the same way as two single-phase units incorporated in the same unit, controlling two independent single-phase loads by two different control signals.By simply modifying the positions of the jumpers on the driver board, the TC2000 series unit can be configured to control a three-phase in a three-wire configuration or to controltwo single-phase loads.The range of nominal currents of the TC2000 series power units is from 60 to 500A (in 3 unit models) at nominal voltages of 120 to 500 V.1-2TC2000 User ManualIdentificationFigure 1-1 Overall view of the TC2000 power unit (PLU or IPU option)TC2000 User Manual 1-3IdentificationThe standard version of the TC2000 series unit (basic version) is equipped with a driver board which performs the feedback, measurement and thyristor firing functions.As an option, a TC2000 unit in a three-phase configuration is equipped with a partial load unbalance board ("PLU board"), which can be plugged into the driver board. With the PLU/ IPU, options, TC2000 series units in a three-phase configuration detect any current unbalance greater than 10%.The partial load unbalance detection is signalled by the indicator light on the front fascia and by a PLU alarm relay switch (switch N/O or N/C depending on, the control code).The user terminal block of the alarm relay switch is located below the unit, to the left.In the PLU / IPU options, the front fascia of the unit comprises:• a "Load Fail" indicator light when the partial load unbalance of the three-phaseload is detected• an "Adjust" potentiometer to adjust the detection• a "Test" push button.The partial load unbalance detection system also triggers the alarm for the following cases:• non-firing of a thyristor• blowing of a fuse of one of the phases• absence of a phase or significant drop in voltage of the phasesof the three-phase supply.The simultaneous failure of the 2 fuses, installed inside the unit on the controlled phases, is detected by the fuse blown indication micro-switches (optional).The supply side power cables pass through the opening of the protective cover.The power cables to the load pass through the cable sheath under the unit.The control wires are connected on the user terminal block of the driver board.They must be shielded and grounded at both ends.The control cable passes through the cable clamp which secures the cable and grounds the shielding simultaneously.The thermal switch inhibits the fan-cooled unit (from 100 A of the nominal current) in the event of thyristor overheating.1-4TC2000 User ManualIdentificationFigure 1-2 Overall view of the TC2000 unit with the access door open (PLU option installed)TC2000 User Manual 1-5IdentificationThe inputs of channels A and B are located on the user terminal block of the driver board.In the three-phase configuration, only one control signal is applied to input A.In the single-phase configuration, two signals are applied to inputs A and B.Solid state contactors.The input signals of the TC2000 series static contactors must be logic.• dc signals- single-phase and three-phase configuration without PLU option:- 10 V- three-phase configuration with PLU option:- 5 V- 10 V- 20 mA• ac signals (three-phase configuration only):- 100 to 240 VacWith the ac signal, the PLU/IPU option is not available.Power thyristor units.The input signals of the TC2000 series power thyristor units must be analogue.• dc voltage signals (single-phase and three-phase configuration):- 0 - 5 V- 0 - 10 V- 1 - 5 V- 2 - 10 V• dc current signals (single-phase and three-phase configuration):- 0 - 20 mA- 4 - 20 mA.The TC2000 series power thyristor units possess a supply voltage variation compensation within the range + 10% to -15% of the nominal voltage.This instantaneous compensation is used to maintain the power transmitted to the loadconstant in spite of the supply voltage variations, thus preventing fluctuations of thecontrolled value.1-6TC2000 User ManualTC2000 User Manual1-7IdentificationTECHNICAL DATA!PowerNominal current (per channel)60 A, 75 A, 100 A, 150 A, 250 A, 300 A400 A, 500 ANominal voltage 120 to 500 Vac line to line (+10% -15%)Frequency 50 or 60 Hz Operation type • Solid state contactorsTyristor firing in Logic (ON/OFF) mode Logic signals• Power thyristor unitsThyristor firing in Burst firing mode Analogue signalsConfiguration type • Three-phaseTwo phase control (only one control signal).• Single-phaseControl of two independent single-phase loads (2 control signals).Three-phase phase rotation Insensitive (except for the PLU option)Thyristor firing Burst firing mode: firing ON/OFF when zero voltage crossingis reached for each of the 2 phases.Load typeResistive loads with low temperature coefficient Configuration typeThree-phase configuration:closed delta or star without Neutral (3 wires)Single-phase configuration:two independent single-phase loads.ThyristorsInternal high-speed fuses .RC snubbers and Varistor at thyristor terminals.Fuse blown trip indicator.As an option, fuse blown indication micro-switches.Auxiliary power supply 1 A external fuse (not supplied)Mechanical protection Covers guaranteeing IP20 protection (in front fascia).Thermal protectionThermal safety switch (stops thyristor firing if the maximum thyristor temperature is exceeded).The TC2000 series is a series of solid state contactors and power thyristor units designed to control the electrical power of industrial three-phase and single-phase loads.Attention !It is the user's responsibility to ensure that the unit is compatible with the conditions of installation before commissioning the unit.LoadProtectionTC2000 User Manual1-8IdentificationUnit Insulated irrespective of the configuration type.Must be connected to earthCoolersInsulated for models up to 250 A Control signalsInsulated from the control circuit.In the single-phase configuration, the 2 dc signals are connected to the same common 0V.Solid state contactors Logic signal which can be selected in the factory Firing type ON/OFF (Logic)• dc signal in standard version -Voltage 10 V V max = 25 VON status V > 5 V (4 mA min)OFF status V < 1 V• dc signalwith PLU option -Voltage 5 V V max = 12 VON status V > 1.5 V (4 mA min)OFF status V < 0.5 V-Voltage 10 V V max = 25 VON status V > 5 V (4 mA min)OFF status V < 1 V-Current 20 mA I max = 40 mAON status I > 4 mA OFF status I < 0.2 mA• ac signal Voltage 100 to 240 V V max = 264 V (PLU not available)ON status V > 85 VOFF status V < 10 V Power thyristor units Analogue signal which can be selected by the user using jumpersFiring type Burst firing, the typical modulation period at 50 % power is 0.6 s (for another period contact as)• dc signal -Voltage 0-5 V; 0-10 V; 1-5 V; 2-10 V -Current 0-20 mA; 4-20 mA • Manual controlExternal 5 k Ω potentiometer Input configured in 0-5 V+ 15 V voltage available on the user terminal block Power supply• Power thyristor units: 115 V or 230 V (+10 %-15 %).The exact definition of the power supply voltage is used to adjust the supply variation compensation accurately.• Solid state contactors with the PLU/IPU options:115 V or 230 V (+10 %-15 %).ControlInsulationTC2000 User Manual1-9IdentificationOperating temperature 0 to 50°C in vertical position (40°C for the 500 A current)Storage temperature - 10°C to 70°CHeat dissipation The thyristor units dissipate on average 1.3 W per A and per phaseCooling• 60 and 75 A Convection cooling, power supply consumption 5 VA • 100 to 150 A Built-in fan, power supply and fan consumption 35 VA• 250 to 500 A Two built-in fans, power supply and fan consumption 70 VA Fan supply115 V or 230 VFor power thyristor units and for static contactors with the PLU/IPU options, the power supply is used to power the fans.Operating altitude 2000 m maximumOperating amosphere Non explosive, non corrosive and non conductive.Pollution Degree 2 (IEC 664)Humidity RH 5% to 95% non condensing.Partial load unbalance (PLU) detection system.An alarm for:• a 10 % unbalance of line currents • a thyristor short circuit • a fuse blow-out• the absence of a phase.Alarm outputRelay deactivated in alarm status.Alarm stored in memory (requiring acknowledge) or not stored in memory according to user cabling.Relay switch N/O open in alarm status (PLU option) or relay switch N/C (closed in alarm status (IPU option))Switch cut-off capacity 0.25 A at 250 Vac or 30 Vdc Power supply required115 V or 230 V .Internal high-speed fuses Fuse blown indication micro-switches (thyristor protection).Conducted emissionsTo reduce the conducted emissions that occur when using thyris-tor units, the EMC internal filters is added(standard for 60 A and 75 A; optional for 100 A and 150 A).Thermal characteristics EnvironmentOptionsPLU / IPU options (three-phase operation only)Fuse blown indication micro-switches Internal CEM filtersTC2000 User Manual1-10IdentificationSeries /Config- /Nominal /Nominal / Auxiliary / Input / Input / Options / 00uration current voltage power supply A BUNIT CODINGNominal line to line voltage Code 120 volts 120V 240 volts 240V 277 volts 277V 440 volts 440V 480 volts 480V 500 volts500VSeriesCode Solid state contactors andpower thyristor unitsTC2000Configuration CodeThree-phase.2 controlled phases 02Single-phase.2 independent phases21Nominal current Code 60 amperes 60A 75 amperes 75A 100 amperes 100A 150 amperes 150A 250 amperes 250A 300 amperes 300A 400 amperes 400A 500 amperes500AFor other voltages , contact your Eurotherm officeAuxiliary power supply Code Without auxiliary power supply 000(60 A and 75 A solid statecontactors without PLU option)230 /115 V single-phase supply:100 volts 100V 110 volts 110V 115 volts 115V 120 volts 120V 200 volts 200V 220 volts 220V 230 volts 230V 240 volts240VTC2000 User Manual1-11IdentificationOptionsCode PLU detection (only in three-phase configurations; analogue or dc logic signal) • relay switch open in alarm status PLU • relay switch closed in alarm status IPU Fuse blown indication micro-switches FUMS No internal fusesNOFUSE Internal EMC filters (100 A and 150 A nominal)FILTInput ACodeThree-phase configuration or single-phase config. channel A Power thyristor units:"Burst mode"thyristor firing Analogue signal0-5 volts 0V51-5 volts 1V50-10 volts 0V102-10 volts2V100-20 milli-amperes 0mA204-20 milli-amperes 4mA20Solid state contactors:"ON/OFF"thyristor firing dc logic signalLGC 100 to 240 Vac logic signal (three-phase only)ACLInput BCode Three-phase configuration 000Power thyristor units:"Burst mode"thyristor firingSingle-phase config. channel B Analogue signal0-5 volts 0V51-5 volts 1V50-10 volts 0V102-10 volts2V100-20 milli-amperes 0mA204-20 milli-amperes 4mA20Solid state contactors:"ON/OFF"thyristor firingSingle-phase config. channel B dc logic signalLGCCODING EXAMPLEInstallation and TC2000 series unit parametersA power thyristor unit for a three-phase load in a delta configuration.• Three-phase configuration on 440 V supply • Nominal current of a phase of the 120 A load• 240 V auxiliary power supply and 0-5 V analogue control• Partial load unbalance detection system, relay switch open in alarm status • Fuse blown indication micro-switches• Internal EMC filters to reduce the conducted emissions.Coding : TC2000 / 02 / 150A / 440V / 240V / 0V5 / 00 / PLU / FUMS / FILT / 00IdentificationTC2000 User ManualInstallationChapter 2INSTALLATIONContents pageSafety during installation...............................................2-2Dimensions...................................................................2-3Mechanical mounting....................................................2-5Installation details..........................................................2-6 TC2000 User Manual 2-1Installation2-TC2000 User ManualInstallationTC2000 User Manual2-3InstallationNominal currentValues60 to 150 A250 A300 to 500 A DescriptionA415 mm415 mm425 mm Height withoutprotective cover B480 mm480 mm570 mm Height with coverC133 mm248 mm248 mm WidthD268 mm268 mm268 mm DepthE88 mm203 mm203 mm Width between the fixingholesF328 mm328 mm328 mm Height between thefixing holesG557 mm557 mm557 mm Depth with thedoor openK350 mm350 mm350 mm Height of lateralfasciasR30 mm50 mm20 mm Distance between "Earth"busbar and panel U138 mm147 mm150 mm Depth between "LOAD"terminal and panel V125 mm148 mm170 mm Depth between "LINE"terminal and panel Poids10 kg16 kg16.5 kg-Table 2-1 Dimensions, fixing values and weights of TC2000 series units2-4TC2000 User ManualInstallation MECHANICAL MOUNTINGTC2000 units have two protective covers (upper and lower).The units can be fixed with the protective covers in place.However, for the connection, the upper protective cover must be removed.After drilling the support panel at the dimensions and values given above, insert the fixing screws half-way in the partition holes or mounting plate.Position the thyristor unit by first inserting the upper screw heads in the respective holes of the upper section.Lower the unit making sure that the lower screws planned can be inserted correctly.Then lower the unit completely until it is in position.Fasten the 4 screws correctly.TC2000 User Manual 2-5Installation2-6TC2000 User ManualCablingChapter 3CABLINGContents pageSafety during cabling....................................................................3-2Fixing power cables.....................................................................3-3Power wiring diagrams.................................................................3-6Three-phase configuration.....................................................3-6Single-phase configuration....................................................3-7Auxiliary power supply.................................................................3-9Control cables............................................................................3-10Fixing....................................................................................3-10Shield connecting to the ground..........................................3-11Driver terminal block..................................................................3-12Input signal connection..............................................................3-13Solid state contactors...........................................................3-13Power thyristor units.............................................................3-15Analogue inputs...............................................................3-15Manual inputs...................................................................3-16PLU alarm signalling (optional)..................................................3-17User terminal block.............................................................3-17PLU board...........................................................................3-18 TC2000 User Manual 3-1Cabling3-2 TC2000 User ManualTC2000 User Manual3-3CablingTable 3-1 Details of power cabling for TC2000 thyristor unitsNominal current 60 to 150 A 250 A 300 to 500 A Supply and load 4 to 70 mm 2120 mm 2185 to 2x150 mm 2Earth cable 16 to 35 mm 2 70 mm 2 95 to 185 mm 2Fuse terminals M8M8M10Tightening torque 13.5 N.m 13.5 N.m 26 N.m Load screwM8M10 M12Tightening torque 12.5 N.m 16.4 N.m 28.8 N.m Earth screwM10 M10M12Tightening torque16.4 N.m16.4 N.m28.8 N.mFIXING POWER CABLESThe supply side power cables pass through the opening of the upper protective cover of the TC2000 unit. The upper covers of the units are raised in order to facilitate the connection of these cables.For connection, this cover, which is fixed to the unit, must be raised. In order to do this:• open the door by unfastening the front screw on the top left-hand corner of the door • raise the door in order to release it from its notches • open the door completely by pulling it towards you• remove the upper cover by unfastening its two fixing nuts by sliding it one cm forwards to release the two catches located at the rear and raising it.The supply side connection is performed on the terminals of each fuse at the upper part of the unit, labelled LINE (see figures 3-2 and 3-3).The load side power cables are placed inside the unit through cable sheaths below the unit.The loads are cabled on screws located in the bottom part of the unit and labelled LOAD (see figures 3-2).The capacities of the power terminals and cabling screws are given in table 3-1.Tightening must not exceed the limit values according to the same table.The cross-section of the connection wires to be used must correspond to the Standard IEC 943Cabling3-4TC2000 User ManualTC2000 User Manual3-5CablingThe power cables to a load pass through cable sheaths whichmust be tightened correctly after cabling.Figure 3-2 Specific power cable connection for 300 to 500 A unitsValues60 to 150 A250 A300 to 500 AM 58 mm 135 mm 110 mm "LINE" terminals 1 and 2P 44 mm 150 mm 110 mm "LOAD" terminals 1 and 2S 50 mm 60 mm 30 mm "Earth" busbar and upper fixing holeT 45 mm 65 mm 96 mm "Earth" busbar and left fixing holeW 68 mm 70 mm 70 mm "LOAD" terminal and lower fixing holeX 20 mm 25 mm 20 mm "LOAD" terminal and left fixing holeY15 mm32 mm20 mm"LINE" terminal and upper fixing holeNominal currentDescription of distanceTable 3-2 Power cabling details!Cabling3-6 TC2000 User Manual。
ctt2000数调分系统常见故障 DSP1、维护台不能正常登录如何处理?答:可能的原因及处理办法如下:原因1:数据库服务管理器没有启动服务或没有打开程序解决办法:启动服务或打开服务管理器程序。
打开程序的方法是点击电脑“开始”→“程序”→“Microsoft sQL Server”→“服务管理器”,程序打开后会在电脑右下角显示服务管理器的图标。
原因2:没有连接到正确的数据库解决办法:打开维护台程序安装目录,双击CTT2000LM.udl文件,出现如下图窗口。
选择正确的数据库,点击测试连接按钮,系统回复“测试连接成功”提示框。
2、维护台不能连接到通信服务器如何处理?答:如果维护台下方交换机链路状态显示为绿色小球,或状态栏中显示“断开与通信服务器的连接”,表示维护台没有与通信服务器正确通信。
产生此错误可能的原因及处理办法如下:原因1:通信服务器没打开解决办法:启动通信服务器程序。
原因2:通信服务器程序死机解决办法:关闭通信服务器程序,再重新启动通信服务器。
如果点击通信服务器的系统菜单“系统”→“退出”没有反应的话,在键盘上按[Ctr1]+[Alt]+[Del]进入Windows的“任务管理器”的“进程”监视界面,如下图所示。
在映像名称下找到CommServer4k.exe (CTT4K 维护台)或CommServer.exe(非CTT4K维护台),单击窗口右下方的结束进程按钮,强行退出通信服务器。
3、系统死机或不能正常退出如何处理?答:系统运行过程中,可能由于某种原因导致系统死机或不能正常退出,解决方法是强制结束维护台及通信服务器程序。
在键盘上按[Ctrl]+[Alt]+[Del]进入Windows的“任务管理器”的“进程”监视界面,在映像名称下找到Cttclient.exe和CommServer.exe,(或Cttclient4k.exe和CommServer4k.exe)单击窗口右下方的结束进程按钮,强行退出客户端程序及通信服务器。
EQUIPMENT COMPONENT INTERVALS LUBRICATION SPECIFICATIONS Truck Engine Oil and Filter Refer to Truck Operating Manual Refer to Truck Operating Manual Driveline Transmission, Drive shafts, Differential Refer to Truck Operating Manual Refer to Truck Operating Manual Auxiliary Engine Oil and Filter Refer to Engine Operating Manual Refer to Engine Operating Manual Auxiliary Engine Coolant Refer to Engine Operating Manual Refer to Engine Operating Manual Auxiliary Engine Fuel Filters Refer to Engine Operating Manual Refer to Engine Operating ManualOMSI Gear Box GearboxAfter 1st 50 HoursThen Every 500 Hours or 12 months75w90 Gear OilMuncie Gearbox GearboxAfter 1st 50 HoursThen Every 500 Hours or 12 months75w90 Gear OilMuncie PTO Jack Shaft WeeklyGeneral Purpose Grease Hydraulic System Hydraulic Fluid Reservoir1000 -1200 hours or every 2 years Aw68Hydraulic System High Pressure Hydraulic Filter After First 100 hoursthen every 500 hoursHydraulic FilterHydraulic System Low Pressure Hydraulic Filter After First 100 hoursthen every 500 hoursHydraulic FilterRoots Vacuum Blower Blower Gear Case oil After First 50 hours and then every2000 hoursISO VG 320 Roots Oil HighTemp - SyntheticDresser Roots Blower Pulley End Bearings(Grease Fittings)Daily(2 pumps Each Fitting)Shell GADUS S2 U1000 2 GreaseHowden Roots VacuumBlower Pulley End Bearings (Grease Fittings)Daily (2 pumps Each Fitting)Blowers with serial # beginning before1608AShell GADUS S2 U1000 2 GreaseBlowers with serial # beginning with1608A and laterRoyal Purple Synthetic GreaseTuthill Blower Pulley End Bearings (Grease Fittings)Daily(2 pumps Each Fitting)Tuthill Lithium Complex GreaseRoots Vacuum Blower Vacuum Filter Inspect Daily Clean or Replace Kunkle Valve Internal Relief Valve Weekly WD-40 or EquivalentJetstream Pump Uni-valvesEvery 100 hours(Lapping Procedure)NAJetstream Pump Crankcase Oil After First 100 hours and then every500 hours75w90 Gear OilHog Head Thru-Shaft Motor Bearings Daily Mobil Polyrex EM Hog Head Thru-Shaft Motor Pre-load Adjustment Weekly NAHog Arm Chassis Wheels And Casters DailyGeneral Purpose GreaseHog Arm Bearings, Hinges and Other GreasefittingsWeeklyGeneral Purpose GreaseGeneral Grease Points Door Hinges, Debris Tank Tilt Pins,Vacuum Door Hinges, Ball Valves,Latches, ETCWeeklyMore Frequently If RequiredGeneral Purpose GreaseThis chart is a guide only. It should never be to supersede equipment manufacturer's specifications. Please refer to the manufacturer's operation and maintenance manuals for additional information.SK2000 Maintenance Matrix。