PVI-2000 PVI-3600 pag. 4
PVI-2000-OUTD pag pag. 6
PVI-3 0-OUTD / S PVI-3.0-OUTD /-S UTD PVI 3 6 OUTD / S PVI-3.6-OUTD /-S PVI-4.2-OUTD /-S pag. 8 PVI-3.8-I-OUTD PVI-4.6-I-OUTD pag. 10
PVI 5000 OUTD PVI-5000-OUTD 0 PVI-5000-OUTD-S PVI-6000-OUTD PVI-6000-OUTD-S pag. 12
PVI 10 0 OUTD / S / FS PVI-10.0-OUTD /-S /-FS PVI 12 5 OUTD / S / FS PVI-12.5-OUTD /-S /-FS pag. 14 PVI-10.0-I-OUTD pag. 16
P PVI AEC EVO PVI-AEC-EVO pag. 18
PVI-DESKTOP pag. 20
PVI-STRINGCOMB PVI-STRINGCOMB STRINGCOMB PVI-STRINGCOMB-S pag. 22
PVI 55 PVI-55 0 PVI-55.0 pag. 24
PVI-110 0 PVI-110.0 PVI-110.0-TL pag. 27
PVI-165 0 PVI-165.0 PVI-165.0-TL PVI-220.0 PVI-220.0-TL pag. 30
PVI-275 0 PVI-275.0 PVI-275.0-TL PVI-330.0 PVI-330.0-TL pag. 33
PVI-STATION-440/660-XX-IT PVI-STATION-770/1000-XX-IT PVI-STATION-1100/1320-XX-IT pag. 36
PVI-STATION-440/660-XX-DE PVI-STATION-770/1000-XX-DE PVI-STATION-1100/1320-XX-DE pag. 38
PVI-3.0-OUTD-XX-W VI-3.0-OUTD-XX-W PVI-3.6-OUTD-XX-W PVI-4.2-OUTD-XX-W pag. 40
PVI-6000-OUTD-US-W VI-6000-OUTD-US-W PVI-6000-OUTD-IT-W VI-6000-OUTD-IT-W PVI-6000-OUTD-ES-W pag. 42
PVI-WIND-INTERFACE pag. 44

PVI-2000 / PVI-3600
AURORA Photovoltaic Inverter
?
General Speci?cations Indoor models PVI-2000 PVI-3600 AURORA BENEFITS . Dual input section to process two strings with independent MPPT (3600W models) . Robust IP21 (NEMA 2) indoor enclosure and conformal coating of the boards conditions . to stand harsh environmentalcontrols for maximum energy harvesting High speed, advanced MPPT . Very compact and light design for ease of installation: 3600W of output power 465mm x 57mm . in a box just 440mm x on the front panelweighting less than 7.5kg (16,5 lbs) Graphical LCD Display . Transformerless operation for highest ef?with integrated data logger ciency: up to 96% . Reverse polarity protection minimizes chance of damage due to mis-wiring . True Sine Wave Output . Anti-islanding protection (in countries where required) . Certi?ed grid connected operation according international standards
SMART CONTROLS
Aurora controls are DSP (Digital Signal Processor) based with sophisticated control and self-diagnostic algorithms. A 128 x 128 graphical LCD display shows the unit’s operating status, its performance and diagnostic messages. Four scrolling keys on the front panel of the unit are used to navigate menus for data display and parameter settings.
STANDARDS AND CODES
Aurora inverters comply with standards set for grid-tied operation, safety and electromagnetic compatibility including: VDE0126, CEI 11-20 IV ed, DK5940, IEC 61683, IEC 61727, EN50081, EN50082, EN61000, CE certi?cation, El Real Decreto RD1663/2000 de Espa?a.
Block Diagram and typIcal ef?ciency (PVI-3600)
Ef?ciency
4

CHARACTERISTICS
INPUT PARAMETERS Nominal DC Power [kW] Max. Recommended DC Power [kW] Operating Input Voltage Range [V] Full Power MPPT input voltage range (symmetrical load) [V] Full asymmetrical load input voltage range [V] Absolute Max. Input Voltage [V] Activation voltage "Vstart" [V] No of independent MPPT trackers Max. Input Power, each MPPT [kW] No. of DC Inputs Max. DC Current, each MPPT [A] DC Connection INPUT PROTECTION Reverse polarity protection Fuse rating, each input (-FS suf?x versions only) DC side varistors PV array Insulation Control DC Switch (-S/-FS suf?x versions only) OUTPUT PARAMETERS Nominal AC Power [up to 40°C, kW] Max. AC Power [kW] AC Grid Connection Nominal AC Voltage [V] Maximum AC Voltage Range [V] Nominal AC Frequency [Hz] Max. AC Line Current [A] AC Connection Line Power Factor AC Current Distortion [THD%] OUTPUT PROTECTION AC side varistors Ground fault protection (AC + DC leakage current) CONVERSION EFFICIENCY Max. Ef?ciency Euro Ef?ciency ENVIRONMENTAL PARAMETERS Cooling Ambient Temp. Range [°C] Opertaing Altitude [m] Acoustical Noise [dBA] Environmental IP Rating Relative Humidity MECHANICAL Dimensions [H x W x D] Weight [kg] OTHER Stand-By Consumption [W] Feed In Power Threshold [W] Night Time consumption [W] Isolation Display Communication AVAILABLE PRODUCT VARIANTS Standard - no options
PVI-2000
2,1 2,3 90 - 580 (360 nominal) 210-530 NA
PVI-3600
3,8 4,2 190-530 200-530 (@ 2kW) / 180-530 (@ 1,8kW)
600 200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input) 200 nominal (adjustable within the range 120Wdc-350Wdc) 1 2 2,1 2 1 2 (1 each MPPT) 10 (12 shortcircuit) 10 (12 shortcircuit) 2 (1 positive, 1 negative) 4 (2 positive, 2 negative) MultiContact ? 3mm (male - positive input + female - negative input) Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable ? w/insulator: 3-6mm Yes NA 2, thermally protected according to VDE0126-1-1 NA 2 2 single phase 230Vac 50Hz + PE 230 180-264 50 9 Circular Bayonet Connector Conductor Cross Section: Solid / Stranded: 0,5-2,5mmq / AWG 20-14 Outer Cable ?: 10-12mm 1 <2,5% at rated power with sine wave voltage 2, plus gas arrester to ground according to VDE0126-1-1 95,5% 94,4% Forced cooling -25 / +55 (output power derating above 40°C) 2000 <30 @1mt (<50 @1mt with fan at full speed) IP21 0-90% non condensing 440 x 465 x 57 6 7,5 8 10 0,3 No isolation, Transformer-less YES (Gra?co) RS485 (cage-clamp connector - Conductor cross section: 0,08-1,5mmq/AWG28-16); RS232 (DB9) Optional “Aurora Easy Control” remote monitoring system PVI-2000 PVI-3600 96,0% 95,0% 16 3,6 3,6 NA 4 ( 2 for each MPPT ), thermally protected
MODEL SUMMARY
MODEL NUMBER
PVI-2000 PVI-3600
POWER
2000W 3600W
5
Rev. 1.6 - 17/03/2010 - Aurora is a trademark by Power-One - Product is subject to technical improvements

PVI-2000-OUTD
AURORA Photovoltaic Inverter
?
General Speci?cations Outdoor models PVI-2000-OUTD
. IP65 (NEMA 4) ruggedized, completely sealed unit to stand the harshest environmental conditions . High speed MPPT for real time power tracking and improved energy harvesting . Compact size and high power density: 2000W of output power in a box just 420mm x 326mm x 141mm . Front heatsink keeps the unit cleaner and more ef?cient over time . Transformerless operation for highest ef?ciency: up to 95,5% . Reverse polarity protection minimizes chance of damage due to mis-wiring . High overload capability: works up to 2000W under most ambient conditions . True Sine Wave Output . Anti-islanding Protection (in countries where required) . Certi?ed grid connected operation according to the international standards . LCD Display on the front to monitor the main parameters . Standard DC Multi-Contact terminals, screw terminals option available
AURORA BENEFITS
SMART CONTROLS
Aurora controls are DSP (Digital Signal Processor) based with sophisticated control and self-diagnostic algorithms. A LCD display shows the main operational parameters. Three LED’s indicate the operating status.
STANDARDS AND CODES
Aurora inverters comply with standards set for grid-tied operation, safety and electromagnetic compatibility including: VDE0126, CEI 11-20 IV ed, DK5940, IEC 61683, IEC 61727, EN50081, EN50082, EN61000, CE certi?cation, El Real Decreto RD1663/2000 de Espa?a.
Block Diagram
6

CHARACTERISTICS
INPUT PARAMETERS Nominal DC Power [kW] Max. Recommended DC Power [kW] Operating Input Voltage Range [V] Full Power MPPT input voltage range (symmetrical load) [V] Full asymmetrical load input voltage range [V] Absolute Max. Input Voltage [V] Activation voltage "Vstart" [V] No of independent MPPT trackers Max. Input Power, each MPPT [kW] No. of DC Inputs Max. DC Current, each MPPT [A] DC Connection INPUT PROTECTION Reverse polarity protection Fuse rating, each input (-FS suf?x versions only) DC side varistors PV array Insulation Control DC Switch (-S/-FS suf?x versions only) OUTPUT PARAMETERS Nominal AC Power [up to 40°C, kW] Max. AC Power [kW] AC Grid Connection Nominal AC Voltage [V] Maximum AC Voltage Range [V] Nominal AC Frequency [Hz] Max. AC Line Current [A] AC Connection Line Power Factor AC Current Distortion [THD%] OUTPUT PROTECTION AC side varistors Ground fault protection (AC + DC leakage current) CONVERSION EFFICIENCY Max. Ef?ciency Euro Ef?ciency ENVIRONMENTAL PARAMETERS Cooling Ambient Temp. Range [°C] Opertaing Altitude [m] Acoustical Noise [dBA] Environmental IP Rating Relative Humidity MECHANICAL Dimensions [H x W x D] Weight [kg] OTHER Stand-By Consumption [W] Feed In Power Threshold [W] Night Time consumption [W] Isolation Display Communication AVAILABLE PRODUCT VARIANTS Standard - no options With DC switch With DC switch and protection fuse/each input
PVI-2000-OUTD
2,1 2,3 90 - 580 (360 nominal) 210-530 NA 600 200 nominal (adjustable within the range 120Vdc-350Vdc) 1 2,1 1 10 (12 shortcircuit) 1 (1 positive, 1 negative) MultiContact ? 3mm (male - positive input + female - negative input) Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable ? w/insulator: 3-6mm Yes NA 2, thermally protected according to VDE0126-1-1 NA 2 2 single phase 230Vac 50Hz + PE 230 180-264 50 9 Circular Bayonet Connector Conductor Cross Section: Solid / Stranded: 0,5-2,5mmq / AWG 20-14 Outer Cable ?: 10-12mm 1 <2,5% at rated power with sine wave voltage 2, plus gas arrester to ground according to VDE0126-1-1 95,5% 94,4% Natural cooling -20 / +60 (output power derating above 50°C) 2000 <40 @1mt IP65 0-100% condensing 420 x 326 x 141 12 8 10 0,3 No isolation, Transformer-less YES (Alphanumeric 2 lines) RS485 (screw terminal block - Conductor cross section: 0,08-1,5mmq/AWG28-16) Optional “Aurora Easy Control” remote monitoring system PVI-2000-OUTD NA NA
MODEL SUMMARY
MODEL NUMBER
PVI-2000-OUTD
POWER
2000W
7
Rev. 1.7 - 17/03/2010 - Aurora is a trademark by Power-One - Product is subject to technical improvements

PVI-3.0-OUTD / PVI-3.6-OUTD / PVI-4.2-OUTD
AURORA Photovoltaic Inverter
?
General Speci?cations Outdoor models PVI-3.0-OUTD / PVI-3.0-OUTD-S PVI-3.6-OUTD / PVI-3.6-OUTD-S PVI-4.2-OUTD / PVI-4.2-OUTD-S AURORA BENEFITS . Dual input section to process two strings with independent MPPT . High speed MPPT for real time power tracking and improved energy harvesting . Transformerless operation for highest ef?ciency: up to 96,8% (Euro 96%) . Reverse polarity protection minimizes chance of damage due to mis-wiring . True Sine Wave Output . Anti-islanding Protection . LCD Display on the front to monitor the main parameters . Integrated DC switch in compliance with VDE 0100-712 (Germany) and CEI 64-8 V4 (Italy) . Standard DC Multi-Contact terminals (model MC4), includes an integrated DC switch
(PVI-X.X-OUTD-S)
STANDARDS AND CODES
Aurora inverters comply with standards set for grid-tied operation, safety and electromagnetic compatibility including: VDE0126, CEI 11-20 IV ed, DK5940, IEC 61683, IEC 61727, EN50081, EN50082, EN61000, CE certi? cation, El Real Decreto RD1663/2000 de Espa?a.
Block Diagram and typical ef?ciency
8

CHARACTERISTICS
INPUT PARAMETERS Nominal DC Power [kW] Max. Recommended DC Power [kW] Operating Input Voltage Range [V] Full Power MPPT input voltage range (symmetrical load) [V] Full asymmetrical load input voltage range [V] Absolute Max. Input Voltage [V] Activation voltage "Vstart" [V] No of independent MPPT trackers Max. Input Power, each MPPT [kW] No. of DC Inputs Max. DC Current, each MPPT [A] DC Connection INPUT PROTECTION Reverse polarity protection Fuse rating, each input (-FS suf?x versions only) Thermally Protected DC side varistor PV array Insulation Control DC Switch (-S/-FS suf?x versions only) OUTPUT PARAMETERS Nominal AC Power [up to 50°C, kW] Max. AC Power [kW] AC Grid Connection Nominal AC Voltage Range [V] Maximum AC Voltage Range [V] Nominal AC Frequency [Hz] Max. AC Line Current [A] AC Connection Line Power Factor AC Current Distortion [THD%] OUTPUT PROTECTION AC side varistors Ground fault protection (AC + DC leakage current) CONVERSION EFFICIENCY Max. Ef?ciency Euro Ef?ciency ENVIRONMENTAL PARAMETERS Cooling Ambient Temp. Range [°C] Opertaing Altitude [m] Acoustical Noise [dBA] Environmental IP Rating Relative Humidity MECHANICAL Dimensions [H x W x D] Weight [kg] OTHER Stand-By Consumption [W] Feed In Power Threshold [W] Night Time consumption [W] Isolation Display Communication AVAILABLE PRODUCT VARIANTS Standard - no options With DC switch
PVI-3.0-OUTD
3,12 3,5
PVI-3.6-OUTD
PVI-4.2-OUTD
3,75 4,375 4,15 4,82 0,7xVstart - 580 (360 nominal) 156-530 120-530 140-530 200-530 (@ 2kW) / 112-530 (@ 1,12kW) 190-530 (@ 3kW) / 90-530 (@ 0,75kW) 190-530 (@ 3kW) / 90-530 (@ 1,38kW) 600 200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input) 2 2 3 2 ( 1 each MPPT ) 3 ( 2 for MPPT1, 1 for MPPT2 ) 10 ( 12,5 short circuit ) 16 ( 20 short circuit ) 4 (2 positive, 2 negative) 6 (3 positive, 3 negative) MultiContact ? 4mm (male - positive input + female - negative input) Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable ? w/insulator: 3-6mm NA Yes NA 4 ( 2 for each MPPT ) according to VDE0126-1-1 Integrated (Max. Voltage Rating : 600Vdc / Max Current Rating: 25A) NA
3,6 4,2 3,96 4,6 single phase ( Live, Neutral, PE ) 200-245 (230 nominal) 180-264 (may vary to comply with regulations in each country) 50 14,5 ( 16 short circuit ) 17,2 ( 19 short circuit ) 20 ( 22 short circuit ) Screw terminal block Conductor cross section: Solid 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6 Cable Gland: M32 - Cable ?: 13-21mm 1 <3,5% at rated power with sine wave voltage 2 ( Live - Neutral / Live - PE ) according to VDE0126-1-1 96,80% 96% Natural cooling -25 / + 60 (output power derating above 50°C) 2000 < 50 @ 1mt IP65 0-100% condensing 547 x 325 x 208 17 8 10 0,3 Transformer-less YES (Alphanumeric 2 lines) RS485 (Screw terminal block - Conductor cross section: 0,08-1,5mmq/AWG28-16) USB connection “Aurora Easy-Control” system for remote control ( Optional ) PVI-3.0-OUTD PVI-3.0-OUTD-S PVI-3.6-OUTD PVI-3.6-OUTD-S PVI-4.2-OUTD PVI-4.2-OUTD-S
3 3,3
MODEL SUMMARY
MODEL NUMBER
PVI-3.0-OUTD/-S PVI-3.6-OUTD/-S PVI-4.2-OUTD/-S
POWER
3000W 3600W 4200W
9
Rev. 1.3 - 17/03/2010 - Aurora is a trademark by Power-One - Product is subject to technical improvements

PVI-3.8-I-OUTD / PVI-4.6-I-OUTD
AURORA Photovoltaic Inverter
?
General Speci?cations Outdoor models PVI-3.8-I-OUTD/PVI-3.8-I-OUTD-S PVI-4.6-I-OUTD/PVI-4.6-I-OUTD-S
. High frequency transformer-isolated topology. . Optimized for use in applications with negative-grounded or positive-grounded PV arrays (thin ?lm modules or “all-back contact” technologies). . Integrated fuse grounding Kit with ground fault detection and interruption (GFDI in acc. to UL1741). Field-con?gurable for positive or negative grounding during installation. . Low leakage current topology. Can be used with high capacitance modules, including thin ?lm laminates on metal substrate and ungrounded PV arrays. . One model for ALL countries, the Internation inverter. Direct ?eld set-up of the speci?c con?guration in
accordance to local regulation is available for all major countries.
NEW FEATURES
AURORA BENEFITS . ...and all the process two strings with independent MPPT, optimize energy harvesting from multiple Dual input section to Isolated version oriented in . arraysspeed (1 sec)different directions. MPPT algorithm for real time power tracking and improved High and precise (>99,,9%) energy harvesting. . High ef?ciencies deliver more energy - up to 96,4% (Euro 96%). . Watertight IP65 enclosure and full rated power available up to 45°C ambient temperature. harshest environmental . Uncompromized performance under the4-button keypad provides conditions. for all operating parameters and laptop-free inverter set-up. Front-panel mounted LCD display with real-time . RS-485 communication interface (for connection to laptop or datalogger). updates . Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP. . Integrated DC switch in compliance with VDE 0100-712 (Germany) and CEI 64-8 V4 (Italy), (PVI-3.8-I-OUTD-S & PVI-4.6-I-OUTD-S). . Standard DC Multi-Contact terminals (model MC4) with mating cable connectors included.
STANDARDS AND CODES
Aurora inverters comply with standards set for grid-tied operation, safety and electromagnetic compatibility including: VDE0126, CEI 11-20 IV ed, DK5940, IEC 61683, IEC 61727, EN50081, EN50082, EN61000, CE certi?cation, El Real Decreto RD1663/2000 de Espa?a.
Block Diagram
+ PV Input 1 + PV Input 1.1 + PV Input 1.2 - PV Input 1.1 - PV Input 1.2 - PV Input 1
MP P T 1
+ PV Input 1.1 + PV Input 1.2 - PV Input 1.1 - PV Input 1.2
D C S w itc h + PV Input 1
M PP T 1
Isolated DC/DC1
+ PV Input 2

DC /AC Inverter
AC Output
- PV Input 1
Iso la te d D C /D C 1

DC /AC Inverter
AC Output
MP P T 2
+ PV Input 2.1 + PV Input 2.2 - PV Input 2.1 - PV Input 2.2 - PV Input 2
+ PV Input 2.1 + PV Input 2.2 - PV Input 2.1 - PV Input 2.2
+ PV Input 2
M P PT 2
Isolated DC/DC2
- PV Input 2
Isolated DC/DC2
PVI-3.8-I-OUTD / PVI-4.6-I-OUTD
PVI-3.8-I-OUTD-S / PVI-4.6-I-OUTD-S
10

CHARACTERISTICS
INPUT PARAMETERS Nominal DC Power [kW] Max. Recommended DC Power [kW] Operating Input Voltage Range [V] Full Power MPPT input voltage range (symmetrical load) [V] Full asymmetrical load input voltage range [V] Max. Input Voltage [V] Activation voltage "Vstart" [V] No of independent MPPT trackers Max. Input Power, each MPPT [kW] No. of DC Inputs Max. DC Current, each MPPT [A] DC Connection INPUT PROTECTION Reverse polarity protection Fuse rating, each input (-FS suf?x versions only) Thermally Protected DC side varistor PV array Insulation Control (ungrounded applications) "Ground fault protection (for positive-grounded or negative-grounded arrays)” DC Switch (-S/-FS suf?x versions only) OUTPUT PARAMETERS Nominal AC Power [up to 45°C, kW] Max. AC Power [kW] AC Grid Connection Nominal AC Voltage Range [V] Maximum AC Voltage Range [V] Nominal AC Frequency [Hz] Max. AC Line Current [A] AC Connection Line Power Factor AC Current Distortion [THD%] OUTPUT PROTECTION AC side varistors Residual current monitoring unit (AC + DC leakage current) CONVERSION EFFICIENCY Max. Ef?ciency Euro Ef?ciency (preliminary) ENVIRONMENTAL PARAMETERS Cooling Ambient Temp. Range [°C] Opertaing Altitude [m] Acoustical Noise [dBA] Environmental IP Rating Relative Humidity MECHANICAL Dimensions [H x W x D] Weight [kg] OTHER Stand-By Consumption [W] Feed In Power Threshold [W] Night Time consumption [W] Isolation Display Communication AVAILABLE PRODUCT VARIANTS Standard - no options With DC switch With DC switch and blocking diode/each input
PVI-3.8-I-OUTD
4,00 4,40
PVI-4.6-I-OUTD
4,80 5,30
0,7xVstart - 540 (360 nominal) 210-480 240-480 210-480 (@ 2,6kW) / 112-480 (@ 1,4kW) 240-480 (@ 3kW) / 130-480 (@ 1,8kW) 540 (560Vpk - not operating condition) 200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input) 2 2,6 3 4 ( 2 for MPPT1, 2 for MPPT2 ) 12,5 (15,6 short circuit) 14 (17 short circuit) 8 (4 positive, 4 negative) MultiContact ? 4mm (male - positive input + female - negative input) Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable ? w/insulator: 3-6mm NA Yes 4 ( 2 for each MPPT ) Yes NA
Integral 1A fuse with GFDI (Ground Fault Detection & Interruption, acc. to UL1741) Integrated ( Max. Voltage Rating : 600Vdc / Max Current Rating: 25A) 3,8 4,18 4,6 5,06
single phase ( Live, Neutral, PE ) 200-245 (230 nominal) 180-264 (may vary to comply with regulations in each country) 50 19 ( 21 short circuit) 22,5 ( 25 short circuit ) Screw terminal block Conductor cross section: Solid 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6 Cable Gland: M32 - Cable ?: 13-21mm 1 <3,5% at rated power with sine wave voltage 2 ( Live - Neutral / Live - PE ) NA 96,40% 96,00% Natural cooling -25 / + 60 (output power derating above 45°C) 2000 < 50 @ 1mt IP65 0-100% condensing
Rev. 1.0 - 31/03/2010 - Aurora is a trademark by Power-One - Product is subject to technical improvements
650 x 325 x 208 24,5 8 20 0,1 High frequency transformer YES (Alphanumeric 2 lines) RS485 (Screw terminal block - Conductor cross section: 0,08-1,5mmq/AWG28-16) “Aurora Easy-Control” system for remote control ( Optional ) PVI-3.8-OUTD PVI-3.8-OUTD-S NA PVI-4.6-OUTD PVI-4.6-OUTD-S NA
MODEL SUMMARY
MODEL NUMBER
PVI-3.8-I-OUTD PVI-3.8-I-OUTD-S PVI-4.6-I-OUTD PVI-4.6-I-OUTD-S
AC POWER
3.8 kW 3.8 kW 4.6 kW 4.6 kW
OPTIONS
Aurora Communicator software simpli? es monitoring via PC. Aurora Easy Control datalogger is available for remote control via Internet.
11

PVI-5000-OUTD / PVI-6000-OUTD
AURORA Photovoltaic Inverter
?
General Speci?cations Outdoor models PVI-5000-OUTD / PVI-5000-OUTD-S PVI-6000-OUTD / PVI-6000-OUTD-S
. Dual input section to process two strings with independent MPPT (6000W max models) . High speed MPPT for real time power tracking and improved energy harvesting . Transformerless operation for highest ef?ciency: up to 97% (96,5% Euro) . Reverse polarity protection minimizes chance of damage due to mis-wiring . High overload capability: works up to 6000W under most ambient conditions . True Sine Wave Output . Anti-islanding Protection . LCD Display on the front to monitor the main parameters . Standard DC Multi-Contact terminals, screw terminals option available
SMART CONTROLS
Aurora controls are DSP (Digital Signal Processor) based with sophisticated control and self-diagnostic algorithms. A LCD display shows the main operational parameters. Three LED’s indicate the operating status.
AURORA BENEFITS
STANDARDS AND CODES
Aurora inverters comply with standards set for grid-tied operation, safety and electromagnetic compatibility including: VDE0126, CEI 11-20 IV ed, DK5940, IEC 61683, IEC 61727, EN50081, EN50082, EN61000, CE certi?cation, El Real Decreto RD1663/2000 de Espa?a.
Block Diagram and typical ef?ciency
SCHEMA A BLOCCHI E RENDIMENTO TIPICO
Ef?ciency
100% 96,5 96,5 75%
97 96,8 96,5 96,2 95,9 95,6
97 96,8 30% 95,9 20%
Power % of Rated
50%
95,3 95 94,7 94,4 94,1 93,8 93,5 93,2 92,9
96,5 96,2
95 250 300 345 DC Voltage (V) 400
10% 480
92,6
12

CHARACTERISTICS
INPUT PARAMETERS Nominal DC Power [kW] Max. Recommended DC Power [kW] Operating Input Voltage Range [V] Full Power MPPT input voltage range (symmetrical load) [V] Full asymmetrical load input voltage range [V] Absolute Max. Input Voltage [V] Activation voltage "Vstart" [V] No of independent MPPT trackers Max. Input Power, each MPPT [kW] No. of DC Inputs Max. DC Current, each MPPT [A] DC Connection INPUT PROTECTION Reverse polarity protection Fuse rating, each input (-FS suf?x versions only) DC side varistors PV array Insulation Control DC Switch (-S/-FS suf?x versions only) OUTPUT PARAMETERS Nominal AC Power [up to 50°C, kW] Max. AC Power [kW] AC Grid Connection Nominal AC Voltage [V] Maximum AC Voltage Range [V] Nominal AC Frequency [Hz] Max. AC Line Current [A] AC Connection Line Power Factor AC Current Distortion [THD%] OUTPUT PROTECTION AC side varistors Ground fault protection (AC + DC leakage current) CONVERSION EFFICIENCY Max. Ef?ciency Euro Ef?ciency ENVIRONMENTAL PARAMETERS Cooling Ambient Temp. Range [°C] Opertaing Altitude [m] Acoustical Noise [dBA] Environmental IP Rating Relative Humidity MECHANICAL Dimensions [H x W x D] Weight [kg] OTHER Stand-By Consumption [W] Feed In Power Threshold [W] Night Time consumption [W] Isolation Display Communication AVAILABLE PRODUCT VARIANTS Standard - no options With DC switch
PVI-5000-OUTD
4,8 5,75
PVI-6000-OUTD
6,2 6,9
0,7xVstart - 580 (360 nominal) 140-530 180-530 220-530 (@ 4kW) / 90-530 (@ 0,8kW) 220-530 (@ 4kW) / 120-530 (@ 2,2kW) 600 200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input) 2 4 4 (2 each MPPT) 18 (22 shortcircuit) 8 x MultiContact ? 4mm (4 male - positive input + 4 female - negative input) Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable ? w/insulator: 3-6mm Yes NA 4 ( 2 for each MPPT ), thermally protected according to VDE0126-1-1 Integrated (Rating: 600Vdc / 25Adc) 4,6 5 single phase 230Vac 50Hz + PE 230 180-264 50 30 Cage-clamp terminal block Conductor Cross Section: Solid: 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6 Cable Gland: M32 - Cable ?: 13-21mm 1 <3,5% at rated power with sine wave voltage 2, plus gas arrester to ground according to VDE0126-1-1 97% 96,40% Natural cooling -25 / +60 (output power derating above 50°C) 2000 <50 @1mt IP65 0-100% condensing 740 x 325 x 208 26 8 10 0,3 No isolation, Transformer-less YES (Alphanumeric 2 lines) RS485 (cage-clamp connector - Conductor cross section: 0,08-1,5mmq/AWG28-16); Usb (service only) Optional “Aurora Easy Control” remote monitoring system PVI-5000-OUTD PVI-5000-OUTD-S PVI-6000-OUTD PVI-6000-OUTD-S 25 6 6 NA
MODEL SUMMARY
MODEL NUMBER
PVI-5000-OUTD PVI-5000-OUTD-S PVI-6000-OUTD PVI-6000-OUTD-S
POWER
5000W 5000W with DC Switch 6000W 6000W with DC Switch
13
Rev. 1.2 - 17/03/2010 - Aurora is a trademark by Power-One - Product is subject to technical improvements

PVI-10.0-OUTD / PVI-12.5-OUTD
AURORA Photovoltaic Inverter
?
General Speci?cations - Outdoor models PVI-10.0-O UTD / PVI-10.0-OUTD-S / PVI-10.0-OUTD-FS PVI-12.5-OUTD / PVI-12.5-OUTD-S / PVI-12.5-OUTD-FS AURORA . Dual indipendent BENEFITS the max con?guration ?exibility of the installation with 3 strings for each MPPT input sections to offer . Transformerless operation for highest ef?ciency: up to 97,7%; Euro: 97,13% (10KW) ; 97,25 (12.5KW) . True 3ph bridge topology for DC/AC output converter . Wide MPPT input voltage range: 200-850Vdc . Flat ef?ciency curve: to ensure consistent and stable performance across the whole input voltage and output . power range at the middle of the input voltage and output power range to ensure betters performance Ef?ciency peaks real operating . underfast and accurateconditions algorithm (response time: 1sec; accuracy: 99,8%) Very dual MPPT . Very low sensitivity to grid disturbances to avoid undesired disconnection from the grid . Wide operating temperature range -25°/+60°C. Maximun output power guaranteed for ambient temperatures no ventilation) . up to 50°C, free convection cooling (DC switch and fuses (see block diagram) PVI-XX.X-OUTD-FS variants include . LCD Display on the front to monitor the main parameters . Anti-islanding Protection . Integrated RS-485 . Standard DC connection with MultiContact MC4 connector . Reverse polarity protection minimizes chance of damage due to mis-wiring STANDARDS AND CODES
Aurora inverters comply with standards set for grid-tied operation, safety and electromagnetic compatibility including: VDE0126, CEI 11-20 IV ed, DK5940, IEC 61683, IEC 61727, EN50081, EN50082, EN61000, CE certi?cation, El Real Decreto RD1663/2000 de Espa?a.
Electrolyte - Free
The string inverter without electrolytic capacitors
Block Diagram and typical ef?ciency
+ P V In p u t 1 .1 + P V In p u t 1 .2 + P V In p u t 1 .3 - P V In p u t 1 .1 - P V In p u t 1 .2 - P V In p u t 1 .3 + P V In p u t 2 .1 + P V In p u t 2 .2 + P V In p u t 2 .3 - P V In p u t 2 .1 - P V In p u t 2 .2 - P V In p u t 2 .3 + P V In p u t 1
MP P T 1
AC O utput N
- P V In p u t 1 + P V In p u t 2
+ PV Input 1.1 + PV Input 1.2 - PV Input 1.1 - PV Input 1.2
DC Sw itch
+ PV Input 1
MPPT 1
AC Output N
- PV Input 1
+ P V In p u t 1 .1 + P V In p u t 1 .2 + P V In p u t 1 .3 - P V In p u t 1 .1 - P V In p u t 1 .2 - P V In p u t 1 .3 + P V In p u t 2 .1 + P V In p u t 2 .2 + P V In p u t 2 .3 - P V In p u t 2 .1 - P V In p u t 2 .2 - P V In p u t 2 .3
10A - 900V
D C S w itc h
+ P V In p u t 1
MP P T 1 AC O u tp u t N
MP P T 2
DC /AC Inverter
L1 L2 L3
+ PV Input 2.1 + PV Input 2.2 - PV Input 2.1
+ PV Input 2
MPPT 2
DC/AC Inverter
U V W Gnd
- P V In p u t 1 + P V In p u t 2
MP P T 2
DC /AC Inverter
L1 L2 L3
- P V In p u t 2
- PV Input 2.2
- PV Input 2
- P V In p u t 2
P V I-10.0-O U T D / P V I-12.5-O U T D
PVI-10.0-OUTD-S / PVI-12.5-OUTD-S
P V I-10.0-O U T D -FS / P V I-12.5-O U T D -FS
PVI-10.0-OUTD Ef?ciency
PVI-12.5-OUTD Ef?ciency
14

CHARACTERISTICS
INPUT PARAMETERS Nominal DC Power [kW] Max. Recommended DC Power [kW] Operating Input Voltage Range [V] Full Power MPPT input voltage range (symmetrical load) [V] Full asymmetrical load input voltage range [V] Absolute Max. Input Voltage [V] Activation voltage "Vstart" [V] No of independent MPPT trackers Max. Input Power, each MPPT [kW] No. of DC Inputs Max. DC Current, each MPPT [A] DC Connection INPUT PROTECTION Reverse polarity protection Fuse rating, each input (-FS suf?x versions only) DC side varistors PV array Insulation Control DC Switch (-S/-FS suf?x versions only) OUTPUT PARAMETERS Nominal AC Power [up to 50°C, kW] Max. AC Power [kW] AC Grid Connection Nominal AC Voltage [V] Maximum AC Voltage Range [V] Nominal AC Frequency [Hz] Max. AC Line Current [A] AC Connection Line Power Factor AC Current Distortion [THD%] OUTPUT PROTECTION AC side varistors Ground fault protection (AC + DC leakage current) CONVERSION EFFICIENCY Max. Ef?ciency Euro Ef?ciency ENVIRONMENTAL PARAMETERS Cooling Ambient Temp. Range [°C] Opertaing Altitude [m] Acoustical Noise [dBA] Environmental IP Rating Relative Humidity MECHANICAL Dimensions [H x W x D] Weight [kg] OTHER Stand-By Consumption [W] Feed In Power Threshold [W] Night Time consumption [W] Isolation Display Communication AVAILABLE PRODUCT VARIANTS Standard - no options With DC switch With DC switch and protection fuse/each input
PVI-10.0-OUTD
10,3 11,4
PVI-12.5-OUTD
12,8 14,3
0,7xVstart - 850 (580 nominal) 300-750 360-750 360-750 (@ 6,5kW) / 216-750 (@ 3,9kW) 445-750 (@ 8kW) / 278-750 (@ 5kW) 900 360 nominal (adjustable within the range 250Vdc-500Vdc, independently/each input) 2 6,5 8 4/6 (2/3 each MPPT, optionally fused) 18 (22 shortcircuit) 8/12 x MultiContact ? 4mm (4/6 male - positive input + 4/6 female - negative input) Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable ? w/insulator: 3-6mm Yes 10Adc / 900Vdc 4 (2 each MPPT), thermally protected according to VDE0126-1-1 Integrated (Rating: 1000Vdc / 25Adc) 10 12,5 11 13,8 3 phase 400Vac 50Hz with or without neutral (3 or 4 wires network) + PE 3x400Vac 311-456Vac (may be limited in acc. to country-speci?c requirements) 50 16,6A per phase (19A short circuit) 20A per phase (22A short circuit) Screw terminal block Conductor Cross Section: Solid: 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6 Cable Gland: M40 - Cable ?: 19-28mm 1 <2% at rated power with sine wave voltage 3, star connected to common point, plus gas arrester to ground according to VDE0126-1-1 97,70% 97,13% Natural cooling -20 / +60 (output power derating above 50°C) 2000 <50 @1mt IP65 0-100% condensing 650 x 650 x 200 38 10 30W <2 No isolation, Transformer-less YES (Alphanumeric 2 lines) RS485 (Screw terminal block - Conductor cross section: 0,08-1,5mmq/AWG28-16) PVI-10.0-OUTD PVI-10.0-OUTD-S PVI-10.0-OUTD-FS PVI-12.5-OUTD PVI-12.5-OUTD-S PVI-12.5-OUTD-FS 97,25%
MODEL SUMMARY
MODEL NUMBER
PVI-10.0-OUTD/-S/-FS PVI-12.5-OUTD/-S/-FS
POWER
10.000W 12.500W
15
Rev. 1.4 - 17/03/2010 - Aurora is a trademark by Power-One - Product is subject to technical improvements

PVI-10.0-I-OUTD
AURORA Photovoltaic Inverter
?
General Speci?cations Outdoor models PVI-10.0-I-OUTD/PVI-10.0-I-OUTD-S/ PVI-10.0-I-OUTD-FS
.NEW FEATURES topology. transformer-isolated . High frequencyuse in applications with negative-grounded or positive-grounded PV arrays Optimized for contact” technologies). . (thin ?lm modules or “all-backwith ground fault detection and interruption (GFDI in acc. to UL1741). Integrated fuse grounding Kit positive . Field-con?gurable fortopology. or negative grounding during installation. including thin ?lm laminates on Low leakage current Can be used with high capacitance modules, metal substrate and ungrounded PV arrays. . One model for ALL countries, the Internation inverter. Direct ?eld set-up of the speci?c con?guration in accordance to
local regulation is available for all major countries.
Isolated Isolated Version
all BENEFITS ....and sectionthe AURORA with independent MPPT, optimize energy harvesting from multiple arrays oriented in different directions. Dual input to process two strings . High speed (1 sec) and precise (>99,,9%) MPPT algorithm for real time power tracking and improved energy harvesting. . High ef?ciencies deliver more energy - up to 96,5% (Euro 96%). Flat ef?ciency curves to ensure consistent and stable the whole input voltage and output power . performance across topology for DC/AC output converter. range. True 3-phase bridge . Ef?ciency is optimized at the middle of the input voltage and output power range to ensure better performance under real operating conditions. . Watertight IP65 enclosure and full rated power available up to 40°C ambient temperature. Uncompromized performance under the harshest environmental conditions. . Front-panel mounted LCD display with 4-button keypad provides real-time updates for all operating parameters and laptop-free inverter set-up. . RS-485 communication interface (for connection to laptop or datalogger). . Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP. . Integrated DC switch in compliance with VDE 0100-712 (Germany) and CEI 64-8 V4 (Italy) (PVI-10.0-I-OUTD-S), also in combination with series string fuses (PVI-10.0-I-OUTD-FS). . Input transient overvoltage protection by means of thermally-protected varistors. . Standard DC Multi-Contact terminals (model MC4) with mating cable connectors included.
STANDARDS AND CODES
Aurora inverters comply with standards set for grid-tied operation, safety and electromagnetic compatibility including: VDE0126, CEI 11-20 IV ed, DK5940, IEC 61683, IEC 61727, EN50081, EN50082, EN61000, CE certi?cation, El Real Decreto RD1663/2000 de Espa?a.
Block Diagram
+ PV Input 1.1 + PV Input 1.2 + PV Input 1.3 - PV Input 1.1 - PV Input 1.2 - PV Input 1.3
+ PV Input 1
M PP T 1
+ PV Input 1.1
DC S w itc h + PV Input 1
10A - 900V
MP P T 1
+ PV Input 1.1
AC Output
(N)
- PV Input 1
+ PV Input 1.2
- PV Input 1.1 - PV Input 1.2 - PV Input 1
AC Output N
Isolated DC/DC1 MP P T 2
+ PV Input 1.2 + PV Input 1.3 - PV Input 1.1 - PV Input 1.2 - PV Input 1.3 10A - 900V + PV Input 2.1 + PV Input 2.2 + PV Input 2.3
DC S w itc h
+ PV Input 1
MP P T 1
AC Output N
- PV Input 1
Isolated DC/DC1 MPPT 2
+ PV Input 2.1 + PV Input 2.2 + PV Input 2.3 - PV Input 2.1 - PV Input 2.2 - PV Input 2.3

DC /A C Inverter
+ PV Input 2
U V W

DC /A C Inverter
+ PV Input 2.1 + PV Input 2.2
+ PV Input 2
U V W
Isolated DC/DC1 MP P T 2

DC /A C Inverter
+ PV Input 2
U V W
Gnd
- PV Input 2
- PV Input 2.1 - PV Input 2.2 - PV Input 2
Gnd
Isolated DC/DC2
- PV Input 2.1 - PV Input 2.2 - PV Input 2.3 - PV Input 2
Gnd
Isolated DC/DC2
Isolated DC/DC2
PVI-10.0-I-OUTD
PVI-10.0-I-OUTD-S
PVI-10.0-I-OUTD-FS
16

CHARACTERISTICS
INPUT PARAMETERS Nominal DC Power [kW] Max. Recommended DC Power [kW] Operating Input Voltage Range [V] Full Power MPPT input voltage range (symmetrical load) [V] Full asymmetrical load input voltage range [V] Max. Input Voltage [V] Activation voltage "Vstart" [V] No of independent MPPT trackers Max. Input Power, each MPPT [kW] No. of DC Inputs Max. DC Current, each MPPT [A] DC Connection INPUT PROTECTION Reverse polarity protection Fuse rating, each input (-FS suf?x versions only) Thermally Protected DC side varistor PV array Insulation Control (ungrounded applications) Ground fault protection (for positive-grounded or negative-grounded arrays) DC Switch (-S/-FS suf?x versions only) OUTPUT PARAMETERS Nominal AC Power [up to 40°C, kW] Max. AC Power [kW] AC Grid Connection Nominal AC Voltage [V] Maximum AC Voltage Range [V] Nominal AC Frequency [Hz] Max. AC Line Current [A] AC Connection Line Power Factor AC Current Distortion [THD%] OUTPUT PROTECTION AC side varistors Residual current monitoring unit (AC + DC leakage current) CONVERSION EFFICIENCY Max. Ef?ciency Euro Ef?ciency ENVIRONMENTAL PARAMETERS Cooling Ambient Temp. Range [°C] Opertaing Altitude [m] Acoustical Noise [dBA] Environmental IP Rating Relative Humidity MECHANICAL Dimensions [H x W x D] Weight [kg] OTHER Stand-By Consumption [W] Feed In Power Threshold [W] Night Time consumption [W] Isolation Display Communication AVAILABLE PRODUCT VARIANTS Standard - no options With DC switch With DC switch and protection fuse/each input
PVI-10.0-I-OUTD
10,5 11,6 0,7xVstart - 540 (350 nominal) 240-480 290-480 (@ 7kW) / 146-480 (@ 3,5kW) 540 (560Vpk - not operating condition) 200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input) 2 7 4/6 (2/3 each MPPT, optionally fused) 24 (30 shortcircuit) 8/12 (4/6 positive, 4/6 negative) MultiContact ? 4mm (male - positive input + female - negative input) Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable ? w/insulator: 3-6mm Yes 10Adc / 900Vdc 4 ( 2 for each MPPT ), thermally protected Yes Integral 1A fuse with GFDI (Ground Fault Detection & Interruption, acc. to UL1741) Integrated (Rating: 600Vdc / 25Adc) 10 11 3 phase 400Vac 50Hz with or without neutral (3 or 4 wires network) + PE 3x400Vac 311-456Vac (may be limited in acc. to country-speci?c requirements) 50 20 A per phase (25A short circuit) Screw terminal block Conductor Cross Section: Solid: 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6 Cable Gland: M40 - Cable ?: 19-28mm 1 <2% at rated power with sine wave voltage 3, star connected to common point, plus gas arrester to ground NA 96,50% 96,00% Natural cooling -20 / +60 (output power derating above 40°C) 2000 <50 @1mt IP65 0-100% condensing 650 x 650 x 200 46 10 30W <0,4 High frequency transformer YES (Alphanumeric 2 lines) RS485 (Screw terminal block - Conductor cross section: 0,08-1,5mmq/AWG28-16) PVI-10.0-OUTD PVI-10.0-OUTD-S PVI-10.0-OUTD-FS
Rev. 1.0 - 31/03/2010 - Aurora is a trademark by Power-One - Product is subject to technical improvements
MODEL SUMMARY
MODEL
PVI-10.0-I-OUTD
AC POWER
10.0kW/400 Vac
OPTIONS
Aurora Communicator software simpli?es monitoring via PC. Aurora Easy Control datalogger is available for remote control via Internet.
17

AURORA EASY CONTROL
AURORA Photovoltaic Inverter
?
General Speci?cation Aurora Easy Control PVI-AEC-EVO
. Remote monitoring of the plant through Ethernet/Internet connection or GSM/GPRS connection (using PVI-GSM-GPRS module). . Plant performance information: energy harvesting, instantaneous power, voltage, current, up to inverter level detail. . RS485 communication port for data acquisition from inverters (up to 64 devices). . Additional RS485 communication port con?gurable for data acquisition from inverters (up to 64 devices) or for data acquisition from ModBus devices s . (Power Meter, Display, …). . Analog inputs to data acquisition from ambient sensor: 2 inputs con?gurable as 0…10Vdc or 4…20mA and 1 input for PT100/PT1000 sensor. . 4 digital inputs con?gurable to manage the Power Reduction Mode functionality or to acquire status signal. . 2 digital inputs con?gurable as pulse inputs (accordingly to IEC62053-31) or to acquire status signal. . 3 relays (rating 250Vac/3A) con?gurable as status output. . 2 digital outputs con?gurable to acquire status signal. . Diagnostic capability with automatic SMS or e-mail sending in case of malfunctioning of the plant (SMS only in case of GPRS/GSM exp. Module). . Complete monitoring service through webportal service*. . Possibility to connect and access the device in case of ?rewall protected LAN. . Possibility to enter the device over LAN and/or Internet with public IP address. . Complete and professional performance and diagnostic reports. . Possibility to connect the device over Bluetooth connection. . Host USB port for data downloading on USB memory stick and device USB port for PC/Laptop connection. . Data storing on SD Memory Card. . External back-up battery (optional).
*Available in case of internet connection or in case of GPRS/GSM exp. module.
AURORA EASY CONTROL BENEFITS
Block Diagram
18

CHARACTERISTICS
GENERAL Operating temperature range: Non operating (storage) temperature range: Environmental protection class: Mounting system: Dimensions: Weight: FUNCTIONS Memory: Display: Inputs: Digital output: Connection interface ext. Interface to inverters: Additional communication port: Max monitoring capability (each RS485 communication port): ELECTRICAL Analog inputs (con?gurable):
PVI-AEC-EVO
-20°C....+60°C -20°C...+85°C IP 20 DIN top hat rail 35 mm (EN50022) 160(Width) x 90(Height) x 63(Length) mm - (9 modules) 360g SD Memory card 1-2 G graphic with 2 lines and 20 characters 2 x analogic/4 + 2 digital Con?gurable output: “impulse” for large display or “status” for alarm activation USB 2.0 Type A-Type B; Bluetooth; Ethernet 1 x RS485 communication port 1 x RS485 comm. port con?gurable as interface to inverter or to standard ModBus devices 64 inverters (string inverters) / 54x55kW conversion modules+54xPVI-STRINGCOMB (central inverters) 2 x 0...10V max. overload: 12Vdc 2 x 4...20mA max. overload: 40mA / 3Vdc 1 x Temperature input PT 1000/PT 100 Status input: Low < 1,5Vdc High > 2,5Vdc (max. overload 7Vdc) Impulse (meter) input: Low = 0Vdc to 7Vdc High = 9Vdc to 24Vdc (max. overload!) 3 x 3A/250Vac 2 x Opto-isolated, max. overload: 27V 50mA 18-48 VDC; 15-36 Vac < 7.5W (during measurement or sensor activation) Lithium type Li2032
Digital inputs: Relays outputs Digital outputs (con?gurable) Supply input: Consumption: Battery for integrated clock:
PVI-AEC-EVO-SERIES
PVI-AEC-EVO PVI-AEC-GPRS (*) PVI-AEC-I/O EXP (*) (**) PVI-AEC-WIRELESS (*) * usable only as expansion modules of PVI-AEC-EVO. ** available starting from Q4 2010.
ACCESSORIES
Description
DATA TRANSMISSION MODE
PVI-AEC-EVO PVI-AEC-GPRS PVI-AEC-WIRELESS Ethernet/Internet x GSM/GPRS x x Wireless 915/864 MHz
Irradiance sensors PVI-AEC-IRR Irradiance sensor 0-10V PVI-AEC-IRR-T Combined irradiance & module temp. sensor 0-10V Module temperature sensors (backside cell temperature) and signal converters PVI-AEC-T100-ADH PT-100 self-adhesive sensor PVI-AEC-CONV-T100-24V PT 100 signal converter (24V supply) Cased temperature sensors (ambient temperature) PVI-AEC-T1000-INTEGR Wind sensors PVI-AEC-WIND PT-1000 sensor in case, with integrated converter Wind speed sensor (anemometer)
19
Rev. 1.5 - 08/09/2009 - Aurora is a trademark by Power-One - Product is subject to technical improvements

PVI-DESKTOP
AURORA Photovoltaic Inverter
?
General Speci?cations Control and monitoring solutions PVI-DESKTOP
Simple, powerful, effective and upgradable
The Aurora? PVI-DESKTOP is the ideal monitoring solution for residential and small commercial photovoltaic applications. Wireless installation, radio communication with the monitored devices and touch screen colour TFT display make the PVI-DESKTOP an appealing solution to customers who want to have production data and devices status available at a glance without use of either computer or internet connection. The software is easily upgradable by free downloading from the web.
Features
? Elegant design. ? 120x90x35 mm (W x H x D). ? Portable display module with Rechargeable Lithium-Ion battery. ? 3”1/2 touch screen TFT Colour RGB. ? USB 2.0 port and optional Bluetooth for PC data download and software upgrading. ? Extended memory on SD card. ? Radio transmission 868MHz (Europe) or 915MHz (North America). ? Up to 300 meters (1000 ft) operating range from inverters. ? Communicate with up to 6 AURORA devices. ? RS485 port for optional wired communication with inverters ? Mono audio speaker
Flexibility
? Triple power supply (DC, USB, integrated Lithium battery) ? Table top or wall mounting. ? Back up time: Up to 3 weeks with fully charged battery. ? Battery recharge through either AC adapter or USB Hi-Power port. ? Very large data storage capability (through standard SD Card) ? Free ?rmware upgrading https://www.doczj.com/doc/ee18445519.html, ? Complete, easy and friendly data collection and representation
Desktop HighLights
20