S S R
Power Solid-state Relay
G3PA-(VD)
Extremely Thin Relays Integrated with Heat Sink
?Downsizing achieved through optimum design of heat sink.?Mounting possible via screws or via DIN track.
?Close mounting possible for linking terminals. (Except for G3P A-260B-VD, G3P A-450B-VD-2.)?Applicable with 3-phase loads.
?Replaceable power element cartridges.
?Conforms to VDE 0160 (finger protection), with a dielectric strength of 4,000V between input and load.?Conforms to VDE 0805, IEC 950.
?Approved by UL, CSA, and VDE (reinforced insulation).
Ordering Information
I List of Models
Model
Isolation Zero cross function
Indicator Applicable output load Rated input voltage G3P A-210B-VD Phototriac coupler
Y es
Y es
10 A at 24 to 240 VAC 5 to 24 VDC
G3P A-220B-VD 20 A at 24 to 240 VAC G3P A-240B-VD 40 A at 24 to 240 VAC G3P A-260B-VD 60 A at 24 to 240 VAC G3P A-210BL-VD No
10 A at 24 to 240 VAC G3P A-220BL-VD 20 A at 24 to 240 VAC G3P A-240BL-VD 40 A at 24 to 240 VAC G3P A-260BL-VD 60 A at 24 to 240 VAC G3P A-210B-VD Y es 10 A at 24 to 240 VAC 24 VAC
G3P A-220B-VD 20 A at 24 to 240 VAC G3P A-240B-VD 40 A at 24 to 240 VAC G3P A-260B-VD 60 A at 24 to 240 VAC G3P A-420B-VD 20 A at 180 to 400 VAC 12 to 24 VDC
G3P A-430B-VD 30 A at 180 to 400 VAC G3P A-420B-VD-220 A at 200 to 480 VAC G3P A-430B-VD-230 A at 200 to 480 VAC G3P A-450B-VD-2
50 A at 200 to 480 VAC
Replacement Parts
I Other Units (Order Separately)
Units that Enable 2-line Switching of 3-phase Power
Name Carry current Load voltage Model
Applicable SSR
Conforms to
VDE Power Device Cartridge
10 A
19 to 264 VAC
G32A-A10-VD DC5-24G3P A-210B-VD DC5-24Y es
G32A-A10L-VD DC5-24G3P A-210BL-VD DC5-24G32A-A10-VD AC24
G3P A-210B-VD AC2420 A
G32A-A20-VD DC5-24G3P A-220B-VD DC5-24G32A-A20L-VD DC5-24G3P A-220BL-VD DC5-24G32A-A20-VD AC24
G3P A-220B-VD AC2440 A
G32A-A40-VD DC5-24G3P A-240B-VD DC5-24G32A-A40L-VD DC5-24G3P A-240BL-VD DC5-24G32A-A40-VD AC24
G3P A-240B-VD AC2460 A
G32A-A60-VD DC5-24G3P A-260B-VD DC5-24G32A-A60L-VD DC5-24G3P A-260BL-VD DC5-24G32A-A60-VD AC24
G3P A-260B-VD AC2420 A 150 to 440VAC
G32A-A420-VD DC12-24G3P A-420B-VD DC12-2430 A G32A-A430-VD DC12-24G3P A-430B-VD DC12-2420 A 180 to 528VAC G32A-A420-VD-2 DC12-24G3P A-420B-VD-2 DC12-2430 A G32A-A430-VD-2 DC12-24G3P A-430B-VD-2 DC12-2450 A G32A-A450-VD-2 DC12-24G3P A-450B-VD-2 DC12-2410 A 75 to 264 VAC G32A-A10G3P A-210B DC5-24No
20 A G32A-A20G3P A-220B DC5-2440 A G32A-A40G3P A-240B DC5-2420 A 180 to 528 VAC G32A-A420G3P A-420B DC5-2430 A
G32A-A430
G3P A-430B DC5-24
Name
Current flow
Model
Applicable SSR
Short-circuit Unit
10 A G32A-D20
G3P A-210B-VD, G3P A-210BL-VD 20 A G3P A-220B-VD, G3P A-220BL-VD G3P A-420B-VD, G3P A-420B-VD-230 A G32A-D40
G3P A-430B-VD, G3P A-430B-VD-240 A
G3P A-240B-VD, G3P A-240BL-VD
S S R
Specifications
I Ratings (at 25°C)
Input
Output
Refer to Engineering Data for further details.
Model
Rated voltage Voltage range Input current impedance Voltage level
Must operate voltage Must release voltage G3PA-210B-VD 5 to 24 VDC
4 to 30 VDC
7 mA max.
4 VDC max.
1 VDC min.
G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-210BL-VD 5 to 24 VDC
4 to 30 VDC
20 mA max.
4 VDC max.
1 VDC min.
G3PA-220BL-VD G3PA-240BL-VD G3PA-260BL-VD G3PA-210B-VD 24 VAC
19.2 to 26.4 VAC
1.4 k ?±20%
19.2 VAC max.
4.8 VAC min.
G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-420B-VD 12 to 24 VDC
9.6 to 30 VDC
7 mA max.
9.2 VDC max.
1 VDC min.
G3PA-430B-VD G3PA-420B-VD-2G3PA-430B-VD-2G3PA-450B-VD-2
Model
Applicable load
Rated load voltage
Load voltage range Load current
Inrush current
G3PA-210B(L)-VD 24 to 240 VAC (50/60 Hz)
19 to 264 VAC (50/60 Hz)
0.1 to 10 A 150 A (60 Hz, 1 cycle)G3PA-220B(L)-VD 0.1 to 20 A 220 A (60 Hz, 1 cycle)G3PA-240B(L)-VD 0.5 to 40 A 440 A (60 Hz, 1 cycle)G3PA-260B(L)-VD 0.5 to 60 A 440 A (60 Hz, 1 cycle)G3PA-420B-VD 180 to 400 VAC (50/60 Hz)
150 to 440 VAC (50/60 Hz)
0.5 to 20 A 220 A (60 Hz, 1 cycle)G3PA-430B-VD 0.5 to 30 A 440 A (60 Hz, 1 cycle)G3PA-420B-VD-2200 to 480 VAC (50/60 Hz)
180 to 528 VAC (50/60 Hz)
0.5 to 20 A 220 A (60 Hz, 1 cycle)G3PA-430B-VD-20.5 to 30 A 440 A (60 Hz, 1 cycle)G3PA-450B-VD-2
0.5 to 50 A
440 A (60 Hz, 1 cycle)
I Characteristics
Item G3PA-
210B(L)-VD
G3PA-
220B(L)-VD
G3PA-
240B(L)-VD
G3PA-
260B(L)-VD
G3PA-
420B-VD
G3PA-
420B-VD-2
G3PA-
430B-VD
G3PA-
430B-VD-2
G3PA-
450B-VD-2
Operate time1/2 of load power source cycle + 1 ms max. (DC Input, -B models)
1 1/
2 of load power source cycle + 1 ms max. (AC Input)
1 ms max. (-BL models)
Release time1/2 of load power source cycle + 1 ms max. (DC Input)
1 1/
2 of load power source cycle + 1 ms max. (AC Input)
Output ON
voltage drop
1.6 V (RMS) max. 1.8 V (RMS) max.
Leakage current 5 mA max. (at 120 VAC)
10 mA max. (at 230 VAC)
10 mA max. (at 120 VAC)
20 mA max. (at 230 VAC)
20 mA
max. (at
400 VAC)
20 mA max. (at
480 VAC)
20 mA
max. (at
400 VAC)
20 mA max. (at 480 VAC)
I2t260 A2S810 A2S260 A2S810 A2S810 A2S Insulation
resistance
100 M? min. (at 500 VDC)
Dielectric
strength
4,000 VAC, 50/60 Hz for 1 min
Vibration
resistance
Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track)
Shock
resistance
Destruction: 300 m/s2 (mounted to DIN track)
Ambient temperature Operating:–30°C to 80°C (with no icing or condensation) Storage:–30°C to 100°C (with no icing or condensation)
Approved standards UL508, CSA C22.2 (No.14, No.950), EN60950 File No.
5915üG
UL508,
CSA
C22.2
(No.14),
EN60947-
4-3 File
No.
6642üG
UL508, CSA
C22.2 (No.14),
EN60947-4-3
File No.
133127üG
UL508,
CSA
C22.2
(No.14),
EN60947-
4-3 File
No.
6642üG
UL508, CSA C22.2 (No.14),
EN60947-4-3 File No.
133127üG
Ambient
humidity
Operating: 45% to 85%
Weight Approx.
260 g Approx.
340 g
Approx.
460 g
Approx.
900 g
Approx.
290 g
Approx.
290 g
Approx.
410 g
Approx.
410 g
Approx.
900 g
S S R
Operation
I Replacement Parts
G32A-A Power Device Cartridge
The G32A-A Power Device Cartridge (a T riac Unit) can be replaced with a new one. When the temperature indicator has changed from pink to red,the triac circuitry may have malfunctioned possibly by an excessive flow of current, in which case, dismount the damaged cartridge for replacement.The damaged cartridge can be replaced with a new one without disconnecting the wires from the G3P A.Improve the heat radiation efficiency of the G3P A before replacing the cartridge.
The G32A-A Power Device Cartridge can withstand an excessive current for a short period of time, such as may be caused accidentally by the short circuitry of the load, in which case the temperature indicator will not turn red.
Appearance
Replacing Power Device Cartridges
When replacing Power Device Cartridges, use the specified model. Using a Power Device Cartridge other than the specified one will result in faulty
operation and destruction of the elements.
Noise Terminal Voltage according to EN55011
Conformance to EN55011 is possible if a capacitor is connected to the load power supply as shown in the diagram below. (G3P
A-VD)Recommended capacitor: NISSEI ELECTRIC Co., L
TD, TYPE R40 (MKT Series), 1 μ
F (Japan only).
Loss Time
Be sure to turn OFF the power supply when replacing the Cartridge. Supplying power with the Cartridge removed may result in malfunction.
G32A-A10(L)-VD G32A-A20(L)-VD
G32A-A40(L)-VD
G32A-A60(L)-VD
G32A-A420-VD(-2)G32A-A430-VD(-2)G32A-A10
G32A-A20G32A-A40
G32A-A450-VD-2
240 VAC
24 VDC
Input
G3PA-VD
Load
I Replacement Procedure
G32A-A10(L)-VD/G32A-A20(L)-VD/G32-A420-VD(-2) Use the special tool (provided) to extract the cartridge for replacement with a new one. Extraction
Follow the procedures below to dismount the Power Device Car-
tridge from the G3P A.
1.Switch off the power.
3.Hook the indented part of the cartridge with the tool and pull up
on the cartridge to remove it.
Mounting
Follow the procedures below to mount the Power Device Cartridge on the G3P A.
1.Apply silicone grease (provided with the G32A-A) to the entire
surface of the heat radiator.2.
ator of the G32A-A or the G3P A.
3.Insert the cartridge into the opening of the G3P A so that the let-
ters on the cartridge and those on the G3P A are in the same direction and side A and side B are even.
4.
5.
Switch on the power and check the G3P A to be sure it works
properly.
G32A-A40(L)-VD/G32A-A60(L)-VD/G32A-A430-VD(-2)/G32A-A450-VD-2
The G32A Power Device Cartridge is mounted and secured with screws to the G3P
A Unit.
Extraction
Follow the procedures below to dismount the G32A-A Power Device
Cartridge from the G3P A.
1.Switch off the power.
2.Remove the terminal cover.
3.Loosen the two centered screws on the sides to dismount the car-
tridge. The screws are connected to terminals 1 and 2.
4.
5.
tridge.
Mounting
1.Apply silicone grease to the entire surface of the heat radiator.
2.
the G32A-A or the G3P A.
Remover
Side A
S S R
3.Insert the cartridge into the opening of the G3P A so that side A and side B are even.
4.Tighten the screws on both the corners with a tightening torque of 0.59 to 0.78 N ·m.
5.Tighten the screws on both the sides with a tightening torque of 0.59 to 0.78 N ·m.
6.Attach the terminal cover.
7.Switch on the power and check the G3P A to be sure it works properly.
I Linking Terminal Connection
?Connecting with linking terminal for G3P A-210B(L)-VD, -220B(L)-
?Connecting with linking terminal for G32A.
SSR1
SSR2
SSR1
SSR2
SSR
G32A Unit
SSR
G32A Unit
* The cover will not fit if Linking terminal
Linking terminal
G3PA-420B-VD
When the temperature indicator has turned from pink to red, the G32-A-A Power Device Car-Use the terminal cover to prevent accidents Linking terminal
Linking terminal
Mounting
DIN track
G3PA G3PA
Panel
DIN track
Panel
80 mm ?
?
?
S S R
Engineering Data
Load Current vs. Ambient Temperature
Note:Close mounting is possible for a maximum of three Units by reducing the load current by 20%. (A minimum clearance of 10 mm must be
provided when mounting four or more Units.)
25
15
406080100
200-20-3060
40
2520
80
Panel
G3PA-220B(L)-VD
G3PA-210B(L)-VD
Ambient temperature (°C)Ambient temperature (°C)
L o a d c u r r e n t (A )
L o a d c u r r e n t (A )
G3PA-430B-VD, G3PA-430B-VD-2G3PA-420B-VD, G3PA-420B-VD-2G3PA-450B-VD-2
Ambient temperature (°C)
L o a d c u r r e n t (A )
Input Voltage vs. Input Current
406080100
200?20?3060
40
42203.5
1128
15111418
20
1055.510
7Panel
Ground
G3P A-220B(L)-VD
G3PA-210B(L)-VD
G3P A-430B-VD
G3P A-420B-VD
L o a d c u r r e n t (A )
G3PA-420B -VD-2, G3PA-430B-VD-2
S S R
40
302420
10
?30103080
30
2016
10
?3010
30
80
100
406080100
200-20-3064
40
4820
184.5
36
151320305740
4530
2010
14927
DIN track
Panel
Ground
Close Mounting (Up to Three)
G3PA-240B(L)-VD
G3PA-260B(L)-VD
G3PA-220B-VD
G3PA-210B-VD
G3PA-210B(L)-VD, G3PA-220B(L)-VD
Inrush Current Resistivity: Non-repetitive
Note:
Keep the inrush current to half the rated value if it occurs repetitively.
G3PA-210B(L)-VD
G3PA-220B(L)-VD, G3PA-420B-VD, G3PA-420B-VD-2
G3PA-240B(L)-VD/260B(L)-VD, G3PA-430B-VD, G3PA-430B-VD-2, G3PA-450B-VD-2
I n r u s h c u r r e n t (A . P e a k )
Energizing time (ms)I n r u s h c u r r e n t (A . P e a k )
Energizing time (ms)
I n r u s h c u r r e n t (A . P e a k )
Energizing time (ms)
S S R
Dimensions
Note:All units are in millimeters unless otherwise indicated.
Two, 4.5 dia. or M4 holes
4.6 dia.
Two, M4
100 max.
G3PA-210B(L)-VD
Mounting Holes
Without Terminal Cover
With Terminal Cover
Linking terminal B1
Linking terminal B2
Two, M3.5
4.6 x
5.6 elliptical hole
Terminal
Arrangement/
Internal Connections
T r g g e r c r c u t
I n p u t
c r c
u t
Two, 4.5 dia. or M4 holes
4.6 dia.
Two, M4
100 max.
G3PA-220B(L)-VD
Mounting Holes
Without Terminal Cover
With Terminal Cover
Linking terminal B1
Two, M3.5
Linking terminal B2
4.6 x
5.6 elliptical hole
Terminal
Arrangement/
Internal Connections
T r g g e r c r c u t
I n p u t c r
c u t
4.6 dia.
Two, M5
100 max.
Two, 4.5 dia. or M4 holes
G3PA-240B(L)-VD
Mounting Holes
Without Terminal Cover
With Terminal Cover
Linking terminal B1
Two, M3.5
Linking terminal B2
4.6 x
5.6 elliptical hole
Terminal
Arrangement/
Internal Connections
T r g g e r c r c u t
I n p u t c r c u t
Two, 4.5 dia. or M4 holes
4.6 dia.
Two, M5
100 max.
Two, M3.5
110 max.
Mounting Holes
With Terminal Cover
Without Terminal Cover
G3PA-260B(L)-VD G3PA-450B-VD-2
4.6 x
5.6 elliptical hole
Terminal Arrangement/ Internal Connections
T r g g e r c r c u t
I n p u t c r c u t
4.5
7.6
2.28.8
13.2
8.690±0.2
25±0.29091
673880Two, M4
Two, M3.5
4.6 dia.
37 max.
4.5 x
5.6 elliptic hole
100 max.
T r g g e r c r c u t
I n p u t c r c u t
100 max.
Linking terminal ?B2
Linking terminal +B1
Cover
Cover
8991
4.5
13
1813
7.6
35±0.267
388090±0.2 4.6 dia.
100 max.
47 max.
4.6 x
5.6 elliptic hole
T wo, M5
T r g g e r c r c u t
I n p u t c r c u t
Linking terminal +B1Linking terminal ?B2
100 max.
S S R
Precautions
Refer to the T echnical Information for SSRs (Cat. No. J137) for gen-eral precautions.
I Correct Use
Load Connection
For an AC load, use a power supply rated at 50 or 60 Hz.The maximum operating frequency is 10 Hz.
The G3P A-(VD) has a built-in varistor for overvoltage protection.At a low applied voltage, such as 24 VAC, the load current is not fully supplied. When the Unit is switched ON, the voltage required to power the Unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage is, the greater the loss time is. This condition, however, will not create any
When attaching a heat sink to the G3P A-(VD), in order to facilitate heat dissipation, apply Silicone Grease or equivalent heat conductive grease on the heat sink. (T oshiba Silicon, Shinetsu Silicon, etc.) Tighten the mounting screws of the heat sink with a torque of 0.78 to 0.98 N ·m.
Noise Terminal Voltage according to EN55011
The G3P A-(VD) conforms to EN55011 standards when a capacitor is connected to the load power supply as shown in the following circuit diagram.
Recommended Capacitor:
NISSEI ELECTRIC Co., L TD, TYPE R40 (MKT Series), 1 μF
G3PA-(VD)
Output
Load
Input
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
T o convert millimeters into inches, multiply by 0.03937. T o convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. K094-E1-04